createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1720177568729
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee1690.00
emd135000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose20-07-2024 16:30:00
tenderQueryClose18-07-2024 16:30:00
technicalBidOpen22-07-2024 16:30:00
publishedDate05-07-2024 17:43:26
publishedByPostCMC_MCOM_MDL
publishedByUserKPE14529 - GOPAL H KASE
bidValidityPeriod120
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonM B Hosur
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9611663485
tenderSupplierListNone
tenderSchedule
createdTs1720177568765
version6
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/OW/WORK_INDENT20846
titleConstruction of Proposed 08 TPD MRF Centre (Material Recovery Facility) of PEB Structure (PRIMARY SHED 3700Sqft Phase-1) at SWM Site Mudhol.
descriptionConstruction of Proposed 08 TPD MRF Centre Material Recovery Facility of PEB Structure PRIMARY SHED 3700Sqft Phase-1 at SWM Site Mudhol
categoryWORKS
categoryTextWorks
ecv6740756.82
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2216
locationNameDMA City Municipal Council Mudhol
provisionalAmount6750000.0
groupOverheadTotal1076979.85
fileNumberCMC/MDL/SWM/MRF/SHED/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17201775690000NoneNoneOther WorksConstruction of Proposed 08 TPD MRF Centre (Material Recovery Facility) of PEB Structure (PRIMARY SHED 3700Sqft Phase-1) at SWM Site Mudhol.5663776.97
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3460041123285Nonecode01KSRB 1-1.14.1: Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. (Item No. 1.14.1 Page No. 8 Vol.1 PWD SR)Cum105.06105.0657.07FalseNoneNoneFalseNoneFalse5995.77420
3460042123285Nonecode02KSRB 2-2.1.2: Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement & formwork shall be paid separately. Specification No. KBS 2.1, (Item No. 2.1.2 Page No. 15 Vol.1 PWD SR)Cum5833.925833.9246.16FalseNoneNoneFalseNoneFalse269293.74720
3460043123285Nonecode03KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115)Cum7192.87192.822.05FalseNoneNoneFalseNoneFalse158601.240
3460044123285Nonecode04KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115)Cum11210.411210.48.42FalseNoneNoneFalseNoneFalse94391.5680
3460045123285Nonecode05KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115)Cum7192.87192.849.41FalseNoneNoneFalseNoneFalse355396.2480
3460046123285Nonecode06KSRB 2-2.2.3.1 :Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No. 2.2.3 Page No. 15 Vol.1 PWD SR & Appendix I page No.115)Cum9694.089694.085.94FalseNoneNoneFalseNoneFalse57582.83520
3460047123285Nonecode07KSRB 2.11 Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (Item No. 2.11 Page No. 18 Vol.1 PWD SR)Tonne92140.792140.77.6737FalseNoneNoneFalseNoneFalse707060.089590
3460048123285Nonecode08KSRB 5-5.4: Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) . (Item No. 5.4 Page No. 9 Vol.2 PWD SR)Cum6580.676580.6728.22FalseNoneNoneFalseNoneFalse185706.50740
3460049123285Nonecode09KSRB 1-1.8: Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work (Item No. 1.8 Page No. 7 Vol.1 PWD SR)Cum488.22488.22322.51FalseNoneNoneFalseNoneFalse157455.83220
3460050123285Nonecode10KSRB 6-6.33: Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Item No. 6.33 Page No. 17 Vol.2 PWD SR)Cum1267.931267.93145.44FalseNoneNoneFalseNoneFalse184407.73920
3460051123285Nonecode11KSRB 8-8.3.1: Providing 15mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.3.1, Page No. 41, Vol.2)Sqm303.85303.85303.84FalseNoneNoneFalseNoneFalse92321.7840
3460052123285Nonecode12Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. (Item No. 11.2, Page No. 77, Vol.2)Kg116.39116.3919518.0FalseNoneNoneFalseNoneFalse2271700.020
3460053123285Nonecode13Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Item No. 7.38, Page No. 26, Vol.2)Sqm585.04585.04951.97FalseNoneNoneFalseNoneFalse556940.52880
3460054123285Nonecode14KSRB 8-8.51 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(Item No. 8.51, Page No. 50, Vol.2)Sqm103.0103.0303.84FalseNoneNoneFalseNoneFalse31295.520
3460055123285Nonecode15KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(Item No. 8.54.1, Page No. 50, Vol.2)No75.1975.19145.44FalseNoneNoneFalseNoneFalse10935.63360
3460056123285Nonecode16KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(Item No. 8.54.1, Page No. 50, Vol.2)No75.1975.19145.44FalseNoneNoneFalseNoneFalse10935.63360
3460057123285Nonecode17KSRB 11-11.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Item No. 11.6.1, Page No. 76, Vol.2)Sqm2711.992711.9914.76FalseNoneNoneFalseNoneFalse40028.97240
3460058123285Nonecode18KSRB 11-11.8.4:Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Item No. 11.8.4, Page No. 77, Vol.2)No25426.625426.62.0FalseNoneNoneFalseNoneFalse50853.20
3460059123285Nonecode19KSRB 11-11.35.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications..(Item No. 11.35.1.1, Page No. 87, Vol.2)Kg465.56465.56300.0FalseNoneNoneFalseNoneFalse139668.00
3460060123285Nonecode20LT Control Panel for PHE Equipments, like raw water, treated water, sump water lift pumps including starter control operating system.Completely made by CRCA fabricated, powder coated paint finished front openable compartment for all feeders requirement with IP-54. Main Panel Incomer : MCCB TPN 63A with CBCT ELR & Ph indicators, meter section with all parameters as required 100A 4 Wire 25kA 415V Aluminium busbars compartment. Outgoings: 63A MCCB feeder- 01No.Outgoings: 16A MPCB feeder - 01Nos Outgoings: 16A MPCB feeder - 03Nos Outgoings: 63/40A MCB feeder- 08NosNo75000.075000.01.0FalseNoneNoneFalseNoneFalse75000.00
3460061123285Nonecode21LT Control Panel for PHE Equipments, like raw water, treated water, sump water lift pumps including starter control operating system.Completely made by CRCA fabricated, powder coated paint finished front openable compartment for all feeders requirement with IP-54. Sub panel-1 Incomer : MCB TPN 63A with CBCT ELR & Ph indicators, section with all parameters as required Market price 63A 4 Wire 16kA 415V Aluminium busbars compartment. Outgoings: 40/63A 4P MCB feeder- 10No. Outgoings: 32A Industrial socket-02Nos. Outgoings: 16A Industrial socket-02Nos.No35000.035000.01.0FalseNoneNoneFalseNoneFalse35000.00
3460062123285Nonecode22LT Cables Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included. 3.5Cx50 Sqmm Al Ar cable Market priceMtr300.0300.040.0FalseNoneNoneFalseNoneFalse12000.00
3460063123285Nonecode234Cx25 Sqmm Al Ar cable Market priceMtr180.0180.030.0FalseNoneNoneFalseNoneFalse5400.00
3460064123285Nonecode244Cx16 Sqmm Al Ar cable Market priceMtr120.0120.030.0FalseNoneNoneFalseNoneFalse3600.00
3460065123285Nonecode254Cx10 Sqmm Cu Ar cable Market priceMtr332.0332.01.0FalseNoneNoneFalseNoneFalse332.00
3460066123285Nonecode264Cx6.0 Sqmm Cu Ar cable Market priceMtr256.0256.01.0FalseNoneNoneFalseNoneFalse256.00
3460067123285Nonecode273Cx6.0 Sqmm Cu Un Ar cable Market priceMtr316.0316.01.0FalseNoneNoneFalseNoneFalse316.00
3460068123285Nonecode283Cx6.0 Sqmm Cu Un Ar cable Market priceMtr300.0300.01.0FalseNoneNoneFalseNoneFalse300.00
3460069123285Nonecode29Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class. 3.5Cx50 Sqmm Al Ar cableSet200.0200.02.0FalseNoneNoneFalseNoneFalse400.00
3460070123285Nonecode304Cx25 Sqmm Al Ar cableSet67.267.22.0FalseNoneNoneFalseNoneFalse134.40
3460071123285Nonecode314Cx16 Sqmm Al Ar cableSet67.267.22.0FalseNoneNoneFalseNoneFalse134.40
3460072123285Nonecode324Cx10 Sqmm Cu Ar cableSet54.454.42.0FalseNoneNoneFalseNoneFalse108.80
3460073123285Nonecode334Cx6.0 Sqmm Cu Ar cableSet54.454.42.0FalseNoneNoneFalseNoneFalse108.80
3460074123285Nonecode343Cx6.0 Sqmm Cu Un Ar cableSet54.454.42.0FalseNoneNoneFalseNoneFalse108.80
3460075123285Nonecode353Cx4.0 Sqmm Cu Un Ar cableSet54.454.42.0FalseNoneNoneFalseNoneFalse108.80
3460076123285Nonecode36Supply & installation of Tinned Copper lugs crimping & wiring to terminal point. 70 Sqmm Al Ar cable (tinned copper lug) Market priceSet250.0250.02.0FalseNoneNoneFalseNoneFalse500.00
3460077123285Nonecode3725 Sqmm Al Ar cable (tinned copper lug) Market priceSet16.016.02.0FalseNoneNoneFalseNoneFalse32.00
3460078123285Nonecode3816 Sqmm Al Ar cable (tinned copper lug)Market priceSet9.959.952.0FalseNoneNoneFalseNoneFalse19.90
3460079123285Nonecode3910 Sqmm Al Ar cable (tinned copper lug) Market priceSet6.46.41.0FalseNoneNoneFalseNoneFalse6.40
3460080123285Nonecode406.0 Sqmm Al Ar cable (tinned copper lug) Market priceSet5.65.61.0FalseNoneNoneFalseNoneFalse5.60
3460081123285Nonecode416.0 Sqmm Al Ar cable (tinned copper lug) Market priceSet5.65.61.0FalseNoneNoneFalseNoneFalse5.60
3460082123285Nonecode424.0 Sqmm Al Ar cable (tinned copper lug) Market priceSet5.65.61.0FalseNoneNoneFalseNoneFalse5.60
3460083123285Nonecode43PVC conduits & Accessories Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws. 19/20mm dia PVC 2mm thick conduit CSR Electrical SR-2022-23, ITEM NO:1.1.1 ,CH-1, PAGE NO-1Mtr68.068.010.0FalseNoneNoneFalseNoneFalse680.00
3460084123285Nonecode4425mm dia PVC 2mm thick conduit CSR Electrical SR-2022-23, ITEM NO:1.1.2 ,CH-1, PAGE NO-1Mtr80.080.010.0FalseNoneNoneFalseNoneFalse800.00
3460085123285Nonecode4532mm dia PVC 2mm thick conduit CSR Electrical SR-2022-23, ITEM NO:1.1.2 ,CH-1, PAGE NO-1Mtr100.0100.010.0FalseNoneNoneFalseNoneFalse1000.00
3460086123285Nonecode4640mm dia PVC 2mm thick conduit CSR Electrical SR-2022-23, ITEM NO:1.1.2 ,CH-1, PAGE NO-1Mtr113.0113.010.0FalseNoneNoneFalseNoneFalse1130.00
3460087123285Nonecode47Point wiring using Copper wire with switch Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit. 1 Light point upto 3Mtr from switch boardNos276.0276.01.0FalseNoneNoneFalseNoneFalse276.00
3460088123285Nonecode481 Light point above 3M upto 6Mtr from switch board CSR Electrical SR-2022-23, ITEM NO:2.1.2 ,CH-1, PAGE NO-3Nos386.0386.01.0FalseNoneNoneFalseNoneFalse386.00
3460089123285Nonecode491 Light point above 6M upto 10Mtr from switch board CSR Electrical SR-2022-23, ITEM NO:2.1.2 ,CH-1, PAGE NO-3Nos567.0567.01.0FalseNoneNoneFalseNoneFalse567.00
3460090123285Nonecode502 Light point above 6Mtr upto 10Mtr from switch board CSR Electrical SR-2022-23, ITEM NO:2.1.2 ,CH-1, PAGE NO-3Nos721.0721.01.0FalseNoneNoneFalseNoneFalse721.00
3460091123285Nonecode512 Light point above 6Mtr upto 10Mtr from switch boardCSR Electrical SR-2022-23, ITEM NO:2.1.2 ,CH-1, PAGE NO-3Nos721.0721.01.0FalseNoneNoneFalseNoneFalse721.00
3460092123285Nonecode523 Light point above 6Mtr upto 10Mtr from switch board CSR Electrical SR-2022-23, ITEM NO:2.1.2 ,CH-1, PAGE NO-3Nos1054.01054.03.0FalseNoneNoneFalseNoneFalse3162.00
3460093123285Nonecode53Circuit main wiring Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit. 1.0 Sqmm Cu FRLS wire CSR Electrical SR-2022-23, ITEM NO:2.3.1 ,CH-1, PAGE NO-3Mtr18.018.0300.0FalseNoneNoneFalseNoneFalse5400.00
3460094123285Nonecode541.5 Sqmm Cu FRLS wire CSR Electrical SR-2022-23, ITEM NO:2.3.4 ,CH-1, PAGE NO-3Mtr26.026.0300.0FalseNoneNoneFalseNoneFalse7800.00
3460095123285Nonecode552.5 Sqmm Cu FRLS wire CSR Electrical SR-2022-23, ITEM NO:2.3.4 ,CH-1, PAGE NO-3Mtr40.040.0300.0FalseNoneNoneFalseNoneFalse12000.00
3460096123285Nonecode564.0 Sqmm Cu FRLS wire CSR Electrical SR-2022-23, ITEM NO:2.3.4 ,CH-1, PAGE NO-3Mtr59.059.050.0FalseNoneNoneFalseNoneFalse2950.00
3460097123285Nonecode576.0 Sqmm Cu FRLS wire CSR Electrical SR-2022-23, ITEM NO:2.3.4 ,CH-1, PAGE NO-3Mtr115.0115.050.0FalseNoneNoneFalseNoneFalse5750.00
3460098123285Nonecode58Switches & sockets outlets in Existing modular box 6A one way switchNos88.088.04.0FalseNoneNoneFalseNoneFalse352.00
3460099123285Nonecode596A 5Pin socket CSR Electrical SR-2022-23, ITEM NO:3.6.3 ,CH-3, PAGE NO-5Nos162.0162.02.0FalseNoneNoneFalseNoneFalse324.00
3460100123285Nonecode60Stepped fan regulator CSR Electrical SR-2022-23, ITEM NO:3.6.4 ,CH-3, PAGE NO-5Nos313.0313.02.0FalseNoneNoneFalseNoneFalse626.00
3460101123285Nonecode616/16A Universal socket CSR Electrical SR-2022-23, ITEM NO:3.6.11 ,CH-3, PAGE NO-5Nos249.0249.02.0FalseNoneNoneFalseNoneFalse498.00
3460102123285Nonecode62Light fixture Supply & fixing of 50W LED light fixture IP 65, included screws accessoris Etc..Considered outdoor type light fitting for equivalent. CSR Electrical SR-2022-23, ITEM NO:11.9.1, PAGE NO-37Nos7390.07390.010.0FalseNoneNoneFalseNoneFalse73900.00
3460103123285Nonecode63Earthing 25x6mm GI Earth Strip Market priceMtr92.092.060.0FalseNoneNoneFalseNoneFalse5520.00
3460104123285Nonecode648.0 SWG GI bare wire Market priceMtr15.215.250.0FalseNoneNoneFalseNoneFalse760.00
3460105123285Nonecode65Supply & installation of Cable Trays fixed with MS angles, hitech & anchor fastner supports at interval 0.9M interval shall be included complete run below ceiling/wall. Supply & installation of GI Ladder type cable tray 300x50mm Market PriceMtr400.0400.020.0FalseNoneNoneFalseNoneFalse8000.00
3460106123285Nonecode66Pipe Earthing Supply & installation of GI PIPE Earthing as per IS:3043 with all installation detailsNos8000.08000.02.0FalseNoneNoneFalseNoneFalse16000.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17201775750000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17201775750000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17201775750000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17201775750000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17201775750000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17201777240000NoneNoneELIGIBILITYAll others conditions as per bid documentsNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneAnnual Turnover Certificate last 5Year (in laksh)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneBid Capacity (in laksh)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Bid Capacity (in laksh)
NoneNoneNoneNone30percentage Of Tender Amount Line of Credit Unconditional From Nationalised or scheduled BankFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneValid Contractror Registration CertificateOthersValid Contractror Registration Certificate
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneWork done certificate in similar nature of Work done for 50percentageof the estimate Amount within the Last 5 Years.OthersWork done certificate in similar nature of Work done for 50percentageof the estimate Amount within the Last 5 Years.
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Valid Contractror Registration CertificateTrueTechnical Bid
Annual Turnover Certificate last 5Year in lakshTrueTechnical Bid
Bid Capacity in lakshTrueTechnical Bid
Work done certificate in similar nature of Work done for 50percentage of the estimate Amount within the Last 5 Years.TrueTechnical Bid
30Percentage Of Tender Amount Line of Credit Unconditional From Nationalised or scheduled Bank.TrueTechnical Bid
Copy of DD for difference amount.TrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone