createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1720177498633
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee690.00
emd54942.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose15-07-2024 16:30:00
tenderQueryClose15-07-2024 11:30:00
technicalBidOpenNone
publishedDate05-07-2024 17:03:07
publishedByPostTMC_CO_KBV
publishedByUserKPE12841 - MOHAMMED YOUSUF
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonCHIEF OFFICER
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber7483764660
tenderSupplierListNone
tenderSchedule
createdTs1720177498667
version4
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/OW/WORK_INDENT20950
titleConstructionn of Proposed 4TPD MRF Centre (Material Recovery Facility) of PEB Structure (PRIMARY SHED) At Kembhavi.
descriptionConstructionn of Proposed 4TPD MRF Centre Material Recovery Facility of PEB Structure (PRIMARY SHED) At Kembhavi
categoryWORKS
categoryTextWorks
ecv2747117.80
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2434
locationNameDMA Town Municipal Council Kembhavi
provisionalAmount3300000.0
groupOverheadTotalNone
fileNumberMRF/KBV/1
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17201774990000NoneNoneOther WorksConstructionn of Proposed 4TPD MRF Centre (Material Recovery Facility) of PEB Structure (PRIMARY SHED) At Kembhavi.2747117.8
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3459925123282Nonecode01Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work In Hard Rock ( requiring blasting) Depth upto 1.50m (Item No. 1.16.1 Page No. 8 Vol.1 PWD SR)Cum581.7581.729.41FalseNoneNoneFalseNoneFalse17107.7970
3459926123282Nonecode02Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates (Item No. 2.1.2 Page No. 15 Vol.1 PWD SR)Cum5947.25947.228.97FalseNoneNoneFalseNoneFalse172290.3840
3459927123282Nonecode03Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115)Cum7322.47322.47.12FalseNoneNoneFalseNoneFalse52135.4880
3459928123282Nonecode04Column baseCum11016.011016.03.06FalseNoneNoneFalseNoneFalse33708.960
3459929123282Nonecode05Hall Grade slabCum7322.47322.428.62FalseNoneNoneFalseNoneFalse209567.0880
3459930123282Nonecode06Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No. 2.2.3 Page No. 15 Vol.1 PWD SR & Appendix I page No.115)Cum9820.89820.84.82FalseNoneNoneFalseNoneFalse47336.2560
3459931123282Nonecode07Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (Item No. 2.11 Page No. 18 Vol.1 PWD SR)Kg93.9393.932987.6FalseNoneNoneFalseNoneFalse280625.2680
3459932123282Nonecode08Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) . (Item No. 5.4 Page No. 9 Vol.2 PWD SR)Cum6708.456708.4535.86FalseNoneNoneFalseNoneFalse240565.0170
3459933123282Nonecode09Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage & all other appurtenaces required to complete the work. (Item No. 1.8 Page No. 7 Vol.1 PWD SR)Cum497.7497.7128.79FalseNoneNoneFalseNoneFalse64098.7830
3459934123282Nonecode10Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Item No. 6.33 Page No. 17 Vol.2 PWD SR)Sqm1292.551292.5591.08FalseNoneNoneFalseNoneFalse117725.4540
3459935123282Nonecode11Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge..(Item No. 8.2.1, Page No. 41, Vol.2)Sqm309.75309.75187.56FalseNoneNoneFalseNoneFalse58096.710
3459936123282Nonecode12Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. (Item No. 11.2, Page No. 77, Vol.2)Kg118.65118.656130.0FalseNoneNoneFalseNoneFalse727324.50
3459937123282Nonecode13Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277,in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Item No. 7.38, Page No. 26, Vol.2)flashingsSqm585.04585.04518.21FalseNoneNoneFalseNoneFalse303173.57840
3459938123282Nonecode14Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge..(Item No. 8.51, Page No. 50, Vol.2)Sqm105.0105.0187.56FalseNoneNoneFalseNoneFalse19693.80
3459939123282Nonecode15Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge..(Item No. 8.54.1, Page No. 50, Vol.2)Sqm76.6576.6591.08FalseNoneNoneFalseNoneFalse6981.2820
3459940123282Nonecode16Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(Item No. 8.54.1, Page No. 50, Vol.2)Sqm76.6576.6591.08FalseNoneNoneFalseNoneFalse6981.2820
3459941123282Nonecode17Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Item No. 11.6.1, Page No. 76, Vol.2)Sqm2764.652764.659.0FalseNoneNoneFalseNoneFalse24881.850
3459942123282Nonecode18Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Item No. 11.8.4, Page No. 77, Vol.2)Each25920.325920.31.0FalseNoneNoneFalseNoneFalse25920.30
3459943123282Nonecode19Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications...(Item No. 11.35.1.1, Page No. 87, Vol.2)Kg474.6474.6240.0FalseNoneNoneFalseNoneFalse113904.00
3459944123282Nonecode20LT Control Panel for PHE Equipments, like raw water, treated water, sump water lift pumps including starter control operating system.Completely made by CRCA fabricated, powder coated paint finished front openable compartment for all feeders requirement with IP-54.Incomer : MCCB TPN 63A with CBCT ELR & Ph indicators, meter section with all parameters as required 100A 4 Wire 25kA 415V Aluminium busbars compartment.Outgoings: 63A MCCB feeder- 01No.Outgoings: 16A MPCB feeder - 01Nos Outgoings: 16A MPCB feeder - 02NosOutgoings: 63/40A MCB feeder- 08NosNo65000.065000.01.0FalseNoneNoneFalseNoneFalse65000.00
3459945123282Nonecode21Sub panel-1 Incomer : MCB TPN 63A with CBCT ELR & Ph indicators, section with all parameters as required 63A 4 Wire 16kA 415V Aluminium busbars compartment.Outgoings: 40/63A 4P MCB feeder- 10No.Outgoings: 32A Industrial socket-02Nos.Outgoings: 16A Industrial socket-02Nos.No35000.035000.01.0FalseNoneNoneFalseNoneFalse35000.00
3459946123282Nonecode22LT Cables Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness 5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included.3.5Cx50 Sqmm Al Ar cablem300.0300.015.0FalseNoneNoneFalseNoneFalse4500.00
3459947123282Nonecode234Cx25 Sqmm Al Ar cablem180.0180.020.0FalseNoneNoneFalseNoneFalse3600.00
3459948123282Nonecode244Cx16 Sqmm Al Ar cablem120.0120.020.0FalseNoneNoneFalseNoneFalse2400.00
3459949123282Nonecode254Cx10 Sqmm Cu Ar cablem332.0332.01.0FalseNoneNoneFalseNoneFalse332.00
3459950123282Nonecode264Cx6.0 Sqmm Cu Ar cablem256.0256.01.0FalseNoneNoneFalseNoneFalse256.00
3459951123282Nonecode273Cx6.0 Sqmm Cu Un Ar cablem316.0316.01.0FalseNoneNoneFalseNoneFalse316.00
3459952123282Nonecode283Cx4.0 Sqmm Cu Un Ar cablem300.0300.01.0FalseNoneNoneFalseNoneFalse300.00
3459953123282Nonecode29Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class.3.5Cx50 Sqmm Al Ar cableSet200.0200.01.0FalseNoneNoneFalseNoneFalse200.00
3459954123282Nonecode304Cx25 Sqmm Al Ar cableSet67.267.22.0FalseNoneNoneFalseNoneFalse134.40
3459955123282Nonecode314Cx16 Sqmm Al Ar cableSet67.267.22.0FalseNoneNoneFalseNoneFalse134.40
3459956123282Nonecode324Cx10 Sqmm Cu Ar cableSet54.454.42.0FalseNoneNoneFalseNoneFalse108.80
3459957123282Nonecode334Cx6.0 Sqmm Cu Ar cableSet54.454.42.0FalseNoneNoneFalseNoneFalse108.80
3459958123282Nonecode343Cx6.0 Sqmm Cu Un Ar cableSet54.454.42.0FalseNoneNoneFalseNoneFalse108.80
3459959123282Nonecode353Cx4.0 Sqmm Cu Un Ar cableSet54.454.42.0FalseNoneNoneFalseNoneFalse108.80
3459960123282Nonecode36Supply & installation of Tinned Copper lugs crimping & wiring to terminal point.70 Sqmm Al Ar cable (tinned copper lug)Set250.0250.01.0FalseNoneNoneFalseNoneFalse250.00
3459961123282Nonecode3725 Sqmm Al Ar cable (tinned copper lug)Set16.016.02.0FalseNoneNoneFalseNoneFalse32.00
3459962123282Nonecode3816 Sqmm Al Ar cable (tinned copper lug)Set9.959.952.0FalseNoneNoneFalseNoneFalse19.90
3459963123282Nonecode3910 Sqmm Cu Ar cable (tinned copper lug)Set6.46.41.0FalseNoneNoneFalseNoneFalse6.40
3459964123282Nonecode406.0 Sqmm Cu Ar cable (tinned copper lug)Set5.65.61.0FalseNoneNoneFalseNoneFalse5.60
3459965123282Nonecode416.0 Sqmm Cu Un Ar cable (tinned copper lug)Set5.65.61.0FalseNoneNoneFalseNoneFalse5.60
3459966123282Nonecode424.0 Sqmm Cu Un Ar cable (tinned copper lug)Set5.65.61.0FalseNoneNoneFalseNoneFalse5.60
3459967123282Nonecode43PVC conduits & Accessories Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws.19/20mm dia PVC 2mm thick conduitm68.068.010.0FalseNoneNoneFalseNoneFalse680.00
3459968123282Nonecode4425mm dia PVC 2mm thick conduitm80.080.010.0FalseNoneNoneFalseNoneFalse800.00
3459969123282Nonecode45Point wiring using Copper wire with switch Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit.1 Light point upto 3Mtr from switch boardNo276.0276.01.0FalseNoneNoneFalseNoneFalse276.00
3459970123282Nonecode461 Light point above 3M upto 6Mtr from switch boardNo386.0386.01.0FalseNoneNoneFalseNoneFalse386.00
3459971123282Nonecode471 Light point above 6M upto 10Mtr from switch boardNo567.0567.01.0FalseNoneNoneFalseNoneFalse567.00
3459972123282Nonecode482 Light point above 3Mtr upto 6Mtr from switch boardNo721.0721.01.0FalseNoneNoneFalseNoneFalse721.00
3459973123282Nonecode492 Light point above 6Mtr upto 10Mtr from switch boardNo721.0721.01.0FalseNoneNoneFalseNoneFalse721.00
3459974123282Nonecode503 Light point above 6Mtr upto 10Mtr from switch boardNo1054.01054.03.0FalseNoneNoneFalseNoneFalse3162.00
3459975123282Nonecode51Circuit main wiring Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit.1.0 Sqmm Cu FRLS wirem18.018.0150.0FalseNoneNoneFalseNoneFalse2700.00
3459976123282Nonecode521.5 Sqmm Cu FRLS wirem26.026.0150.0FalseNoneNoneFalseNoneFalse3900.00
3459977123282Nonecode532.5 Sqmm Cu FRLS wirem40.040.0150.0FalseNoneNoneFalseNoneFalse6000.00
3459978123282Nonecode544.0 Sqmm Cu FRLS wirem59.059.050.0FalseNoneNoneFalseNoneFalse2950.00
3459979123282Nonecode556.0 Sqmm Cu FRLS wirem115.0115.050.0FalseNoneNoneFalseNoneFalse5750.00
3459980123282Nonecode56Switches & sockets outlets in Existing modular box 6A one way switchNo88.088.04.0FalseNoneNoneFalseNoneFalse352.00
3459981123282Nonecode576A 5Pin socketNo162.0162.02.0FalseNoneNoneFalseNoneFalse324.00
3459982123282Nonecode58Stepped fan regulatorNo313.0313.02.0FalseNoneNoneFalseNoneFalse626.00
3459983123282Nonecode596/16A Universal socketNo249.0249.02.0FalseNoneNoneFalseNoneFalse498.00
3459984123282Nonecode60Light fixture Supply & fixing of 100W LED light fixture IP 65, included screws accessoris Etc..Considered outdoor type light fitting for equivalent.No7390.07390.08.0FalseNoneNoneFalseNoneFalse59120.00
3459985123282Nonecode61Earthing 25x6mm GI Earth Stripm92.092.060.0FalseNoneNoneFalseNoneFalse5520.00
3459986123282Nonecode62Earthing 8.0 SWG GI bare wirem15.215.250.0FalseNoneNoneFalseNoneFalse760.00
3459987123282Nonecode63Supply & installation of Cable Trays fixed with MS angles, hitech & anchor fastner supports at interval 0.9M interval shall be included complete run below ceiling/wall.Supply & installation of GI Ladder type cable tray 300x50mmm400.0400.020.0FalseNoneNoneFalseNoneFalse8000.00
3459988123282Nonecode64Supply & installation of GI PIPE Earthing as per IS:3043 with all installation detailsNo8000.08000.01.0FalseNoneNoneFalseNoneFalse8000.00
3459989123282Nonecode65Misscellaneous & Rounding off chargesNo253.9253.91.0FalseNoneNoneFalseNoneFalse253.90
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17201775020000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17201775020000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17201775020000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17201775040000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17201775040000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17201775040000NoneNoneELIGIBILITYMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)None
17201775040000NoneNoneELIGIBILITYSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)None
17201775040000NoneNoneELIGIBILITYTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNone
17201775040000NoneNoneELIGIBILITYTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNone
17201775040000NoneNoneELIGIBILITYTotal value of civl engineering works executed and payments received in the last five years (year-wise)None
17201775040000NoneNoneELIGIBILITYList of existing commitments and ongoing worksNone
17201775040000NoneNoneELIGIBILITYList of works for which tenders already submittedNone
17201775040000NoneNoneELIGIBILITYBanker Details for referenceNone
17201775040000NoneNoneELIGIBILITYConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNone
17201775040000NoneNoneELIGIBILITYReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNone
17201775040000NoneNoneELIGIBILITYQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNone
17201775040000NoneNoneELIGIBILITYProposals for subcontracting components of works amounting to more than 20% of the contract price (for each, the qualifications and experience of the identified sub-contractor in the relevant fields should be attached)None
17201775220000NoneNoneELIGIBILITYTender rates are excluding GST and hence bidders are adviced to quote the rates excluding GST only. Later in the agreement GST will be added as per govt rulesNone
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
KPWD CIVIL CONTRA CTOR Class-III & aboveTrueTechnical Bid
Annual Turnover Certificate as per tender documentTrueTechnical Bid
Work Done Certificate as per tender documentTrueTechnical Bid
Bankers certificate as per tender documentTrueTechnical Bid
GST Registation certificateTrueTechnical Bid
all documents as per tender documentsTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone