| 3255298 | 112778 | None | code01 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. In area of light jungle | Sqm | 1155.66 | 1155.66 | 7.67 | False | None | None | False | None | False | 8863.9122 | 0 |
| 3255299 | 112778 | None | code02 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 105.06 | 105.06 | 199.12 | False | None | None | False | None | False | 20919.5472 | 0 |
| 3255300 | 112778 | None | code03 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of
chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 121.54 | 121.54 | 115.74 | False | None | None | False | None | False | 14067.0396 | 0 |
| 3255301 | 112778 | None | code04 | PCC (1:3:6) Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6168.67 | 6168.67 | 29.82 | False | None | None | False | None | False | 183949.7394 | 0 |
| 3255302 | 112778 | None | code05 | RCC (M20) Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub-structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).M20 Design Mix Using 20 mm nominal size gradedcrushed coarse aggregates | Cum | 7033.71 | 7033.71 | 31.21 | False | None | None | False | None | False | 219522.0891 | 0 |
| 3255303 | 112778 | None | code06 | RCC (M20) Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size gradedcrushed coarse aggregates - Ground Floor | Cum | 11609.13 | 11609.13 | 7.04 | False | None | None | False | None | False | 81728.2752 | 0 |
| 3255304 | 112778 | None | code07 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6580.67 | 6580.67 | 19.54 | False | None | None | False | None | False | 128586.2918 | 0 |
| 3255305 | 112778 | None | code08 | RCC (M20) Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub-structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).M20 Design Mix Using 20 mm nominal size gradedcrushed coarse aggregates -Ground Floor | Cum | 9769.04 | 9769.04 | 9.78 | False | None | None | False | None | False | 95541.2112 | 0 |
| 3255306 | 112778 | None | code09 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications. | Cum | 164.8 | 164.8 | 86.79 | False | None | None | False | None | False | 14302.992 | 0 |
| 3255307 | 112778 | None | code10 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - Ground Floor | Cum | 10926.24 | 10926.24 | 11.21 | False | None | None | False | None | False | 122483.1504 | 0 |
| 3255308 | 112778 | None | code11 | RCC (M20) Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub-structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7815.23 | 7815.23 | 6.91 | False | None | None | False | None | False | 54003.2393 | 0 |
| 3255309 | 112778 | None | code12 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Ground Floor | Cum | 10243.35 | 10243.35 | 23.71 | False | None | None | False | None | False | 242869.8285 | 0 |
| 3255310 | 112778 | None | code13 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - Ground Floor | Sqm | 1349.3 | 1349.3 | 51.27 | False | None | None | False | None | False | 69178.611 | 0 |
| 3255311 | 112778 | None | code14 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Ground Floor | Sqm | 1267.93 | 1267.93 | 60.49 | False | None | None | False | None | False | 76697.0857 | 0 |
| 3255312 | 112778 | None | code15 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ground Floor | Sqm | 303.85 | 303.85 | 74.27 | False | None | None | False | None | False | 22566.9395 | 0 |
| 3255313 | 112778 | None | code16 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:3 (1 cement: 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ground Floor | Sqm | 376.98 | 376.98 | 95.02 | False | None | None | False | None | False | 35820.6396 | 0 |
| 3255314 | 112778 | None | code17 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.- Ground Floor | Sqm | 364.62 | 364.62 | 96.21 | False | None | None | False | None | False | 35080.0902 | 0 |
| 3255315 | 112778 | None | code18 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
** Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent. Ground Floor | Sqm | 2539.98 | 2539.98 | 21.76 | False | None | None | False | None | False | 55269.9648 | 0 |
| 3255316 | 112778 | None | code19 | Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement
slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge Ground Floor | Sqm | 2659.46 | 2659.46 | 25.92 | False | None | None | False | None | False | 68933.2032 | 0 |
| 3255317 | 112778 | None | code20 | RCC (M20) Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size gradedcrushed coarse aggregates - FIRST Floor | Cum | 12304.59 | 12304.59 | 4.72 | False | None | None | False | None | False | 58077.6648 | 0 |
| 3255318 | 112778 | None | code21 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - First Floor | Cum | 11532.1 | 11532.1 | 14.04 | False | None | None | False | None | False | 161910.684 | 0 |
| 3255319 | 112778 | None | code22 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates First Floor | Cum | 10759.61 | 10759.61 | 23.08 | False | None | None | False | None | False | 248331.7988 | 0 |
| 3255320 | 112778 | None | code23 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.-First Floor | Sqm | 1362.79 | 1362.79 | 165.24 | False | None | None | False | None | False | 225187.4196 | 0 |
| 3255321 | 112778 | None | code24 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - First Floor | Sqm | 1280.61 | 1280.61 | 22.35 | False | None | None | False | None | False | 28621.6335 | 0 |
| 3255322 | 112778 | None | code25 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. First Floor | Sqm | 306.89 | 306.89 | 298.39 | False | None | None | False | None | False | 91572.9071 | 0 |
| 3255323 | 112778 | None | code26 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:3 (1 cement: 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. First Floor | Sqm | 380.75 | 380.75 | 132.42 | False | None | None | False | None | False | 50418.915 | 0 |
| 3255324 | 112778 | None | code27 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.- First Floor | Sqm | 368.27 | 368.27 | 146.86 | False | None | None | False | None | False | 54084.1322 | 0 |
| 3255325 | 112778 | None | code28 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
** Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent. First Floor | Sqm | 2565.38 | 2565.38 | 21.76 | False | None | None | False | None | False | 55822.6688 | 0 |
| 3255326 | 112778 | None | code29 | Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement
slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. First Floor | Sqm | 2686.05 | 2686.05 | 25.92 | False | None | None | False | None | False | 69622.416 | 0 |
| 3255327 | 112778 | None | code30 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.- First Floor | Sqm | 1222.35 | 1222.35 | 102.05 | False | None | None | False | None | False | 124740.8175 | 0 |
| 3255328 | 112778 | None | code31 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. First Floor | Sqm | 924.83 | 924.83 | 14.18 | False | None | None | False | None | False | 13114.0894 | 0 |
| 3255329 | 112778 | None | code32 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. First Floor | Sqm | 1448.1 | 1448.1 | 3.5 | False | None | None | False | None | False | 5068.35 | 0 |
| 3255330 | 112778 | None | code33 | RCC (M20) Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size gradedcrushed coarse aggregates - SECOND Floor | Cum | 12304.57 | 12304.57 | 7.31 | False | None | None | False | None | False | 89946.4067 | 0 |
| 3255331 | 112778 | None | code34 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - Second Floor | Cum | 11532.09 | 11532.09 | 15.23 | False | None | None | False | None | False | 175633.7307 | 0 |
| 3255332 | 112778 | None | code35 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Second Floor | Cum | 10759.6 | 10759.6 | 28.26 | False | None | None | False | None | False | 304066.296 | 0 |
| 3255333 | 112778 | None | code36 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.-Second Floor | Sqm | 1376.29 | 1376.29 | 215.25 | False | None | None | False | None | False | 296246.4225 | 0 |
| 3255334 | 112778 | None | code37 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - Second Floor | Sqm | 1293.29 | 1293.29 | 63.32 | False | None | None | False | None | False | 81891.1228 | 0 |
| 3255335 | 112778 | None | code38 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Second Floor | Sqm | 309.93 | 309.93 | 360.39 | False | None | None | False | None | False | 111695.6727 | 0 |
| 3255336 | 112778 | None | code39 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:3 (1 cement: 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Second Floor | Sqm | 384.52 | 384.52 | 158.7 | False | None | None | False | None | False | 61023.324 | 0 |
| 3255337 | 112778 | None | code40 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.- Second Floor | Sqm | 371.91 | 371.91 | 288.88 | False | None | None | False | None | False | 107437.3608 | 0 |
| 3255338 | 112778 | None | code41 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
** Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent. Second Floor | Sqm | 2590.78 | 2590.78 | 52.23 | False | None | None | False | None | False | 135316.4394 | 0 |
| 3255339 | 112778 | None | code42 | Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement
slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Second Floor | Sqm | 2712.65 | 2712.65 | 51.84 | False | None | None | False | None | False | 140623.776 | 0 |
| 3255340 | 112778 | None | code43 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.- Second Floor | Sqm | 1234.46 | 1234.46 | 102.05 | False | None | None | False | None | False | 125976.643 | 0 |
| 3255341 | 112778 | None | code44 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. Second Floor | Sqm | 933.98 | 933.98 | 14.18 | False | None | None | False | None | False | 13243.8364 | 0 |
| 3255342 | 112778 | None | code45 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. Second Floor | Sqm | 1462.44 | 1462.44 | 3.5 | False | None | None | False | None | False | 5118.54 | 0 |
| 3255343 | 112778 | None | code46 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification | Tonne | 92140.71 | 92140.71 | 18.75 | False | None | None | False | None | False | 1727638.3125 | 0 |
| 3255344 | 112778 | None | code47 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 141.11 | 141.11 | 1119.18 | False | None | None | False | None | False | 157927.4898 | 0 |
| 3255345 | 112778 | None | code48 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade,after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 183.34 | 183.34 | 531.96 | False | None | None | False | None | False | 97529.5464 | 0 |
| 3255346 | 112778 | None | code49 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete
as per specifications. | Cum | 127928.06 | 127928.06 | 0.13 | False | None | None | False | None | False | 16630.6478 | 0 |
| 3255347 | 112778 | None | code50 | Solid core board flush doors 30 mm both side commercial | Cum | 1648.0 | 1648.0 | 4.2 | False | None | None | False | None | False | 6921.6 | 0 |
| 3255348 | 112778 | None | code51 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer: Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 121.54 | 121.54 | 701.82 | False | None | None | False | None | False | 85299.2028 | 0 |
| 3255349 | 112778 | None | code52 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with
Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall
thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) | Sqm | 5890.57 | 5890.57 | 28.56 | False | None | None | False | None | False | 168234.6792 | 0 |
| 3255350 | 112778 | None | code53 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC: Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. | Sqm | 841.51 | 841.51 | 136.42 | False | None | None | False | None | False | 114798.7942 | 0 |
| 3255351 | 112778 | None | code54 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter | m | 299.73 | 299.73 | 52.0 | False | None | None | False | None | False | 15585.96 | 0 |
| 3255352 | 112778 | None | code55 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes of 150mm dia conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. | m | 585.04 | 585.04 | 41.75 | False | None | None | False | None | False | 24425.42 | 0 |
| 3255353 | 112778 | None | code57 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 8524.28 | 8524.28 | 14.4 | False | None | None | False | None | False | 122749.632 | 0 |
| 3255354 | 112778 | None | code58 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 2711.99 | 2711.99 | 14.4 | False | None | None | False | None | False | 39052.656 | 0 |
| 3255355 | 112778 | None | code59 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 172.01 | 172.01 | 43.2 | False | None | None | False | None | False | 7430.832 | 0 |
| 3255356 | 112778 | None | code60 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 581.95 | 581.95 | 378.14 | False | None | None | False | None | False | 220058.573 | 0 |
| 3255357 | 112778 | None | code61 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 291.49 | 291.49 | 64.8 | False | None | None | False | None | False | 18888.552 | 0 |
| 3255358 | 112778 | None | code62 | Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete. For Straight Portion | Sqm | 4108.67 | 4108.67 | 67.58 | False | None | None | False | None | False | 277663.9186 | 0 |
| 3255359 | 112778 | None | code01 | Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover,and cistern fittings, nuts, bolts and gasket etc complete. | Each | 11560.72 | 11560.72 | 2.0 | False | None | None | False | None | False | 23121.44 | 0 |
| 3255360 | 112778 | None | code02 | Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85g. | Each | 170.98 | 170.98 | 6.0 | False | None | None | False | None | False | 1025.88 | 0 |
| 3255361 | 112778 | None | code03 | Providing and fixing in position brass stop cock of approved quality of as per dia nominal bore including cost of all materials,labour and HOM of equipments with all leads complete.a. 15 Nominal Bore
as per specifications | Each | 307.97 | 307.97 | 6.0 | False | None | None | False | None | False | 1847.82 | 0 |
| 3255362 | 112778 | None | code04 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 453x357 mm | Sqm | 1048.54 | 1048.54 | 2.0 | False | None | None | False | None | False | 2097.08 | 0 |
| 3255363 | 112778 | None | code05 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : * 100 mm inlet and 100 mm outlet * Sand cast iron S&S as per IS: 3989 | Each | 1433.76 | 1433.76 | 4.0 | False | None | None | False | None | False | 5735.04 | 0 |
| 3255364 | 112778 | None | code06 | Supplying of 1440 rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 12" Sweep (300 mm) | Each | 3058.07 | 3058.07 | 2.0 | False | None | None | False | None | False | 6116.14 | 0 |
| 3255365 | 112778 | None | code07 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :Size 600x450x200 mm | Each | 5234.46 | 5234.46 | 2.0 | False | None | None | False | None | False | 10468.92 | 0 |
| 3255366 | 112778 | None | code08 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal dia Pipes | m | 249.26 | 249.26 | 80.0 | False | None | None | False | None | False | 19940.8 | 0 |
| 3255367 | 112778 | None | code09 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 20 mm dia GM (Copper alloy) Gate valves | Each | 914.64 | 914.64 | 2.0 | False | None | None | False | None | False | 1829.28 | 0 |
| 3255368 | 112778 | None | code10 | Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. 2 HP, Size 65x50 Head 13M, Discharge 462 LPM | Each | 16078.3 | 16078.3 | 1.0 | False | None | None | False | None | False | 16078.3 | 0 |
| 3255369 | 112778 | None | code11 | Supply and delivery at site brand new best make Foot valve suitable for centrifugal pump upto 10HP confirming with ISI mark and its latest amendments | Each | 1802.5 | 1802.5 | 1.0 | False | None | None | False | None | False | 1802.5 | 0 |
| 3255370 | 112778 | None | code12 | Supply and delivery at site brand new best make starter/ control panel suitable for following HP centrifugal pump confirming with ISI mark and its latest amendments.Upto 7.5 HP centrifugal pump | Each | 9785.0 | 9785.0 | 1.0 | False | None | None | False | None | False | 9785.0 | 0 |
| 3255371 | 112778 | None | code13 | Supplying and fixing LT cable of size 4 x 25 Sqm suitable for centrifugal pump sets with ISI mark and its latest amendments | m | 578.86 | 578.86 | 3.0 | False | None | None | False | None | False | 1736.58 | 0 |
| 3255372 | 112778 | None | code14 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank | Ltr | 9.27 | 9.27 | 2000.0 | False | None | None | False | None | False | 18540.0 | 0 |
| 3255373 | 112778 | None | code15 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 | Each | 423.33 | 423.33 | 80.0 | False | None | None | False | None | False | 33866.4 | 0 |
| 3255374 | 112778 | None | code16 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5[PWD SR 2023-24 Vol:2, P.NO.126, I.No:13.53] | Each | 5811.26 | 5811.26 | 2.0 | False | None | None | False | None | False | 11622.52 | 0 |
| 3255375 | 112778 | None | code17 | Providing lowering laying, jointing, testing and commissioning of following diameters glazed stone ware pipes, conforming to IS 651:1992, (with 5th revision) in all respects jointing with EPDM rubber rings (seals according to EN 681 & ASPM 425) The rubber seals joints pipe will have groves in interior of socket and exterior of the spigot. The rubber gasket shall be prefixed at the factory by the manufacturer rigidly with approved glue to have leak proof joint including conveying of pipe to work site and rolling and lowering into trenches, laying true to line, level and perfect linking at joints testing and commissoning including loading and unloading at both destinations and cuts of pipes wherever
necessary including jointing of GSW pipes and specials, with rubber gaskets conforming to EN 681 and ASTM C-425 including cleaning the socket and spigot with soap solution and applying talcum powder for detecting crack, then applying glue and before inserting of rubber gaskets, jacking and fixing in perfect condition including the cost of soap solution, talcum powder and glue etc. and giving necessary hydraulic test to the required pressure of water head with all lead and lifts including
costing of jointing materials and all necessary survey works for laying of sewers etc., and disposal of debris as directed etc., complete. (Contractor will make his own arrangements for procuring water for testing) with Rubber ring gasket joints. 150 mm dia. pipes | m | 642.72 | 642.72 | 30.0 | False | None | None | False | None | False | 19281.6 | 0 |
| 3255376 | 112778 | None | code18 | Laying,Lowering and jointing of S&S RCC SPUN / VIBRATED CAST PIPES (REINFORCED) pipes NP-3 Class ,rolling and lowering into trenches, laying true to line and level at both destinations and jointing of pipes and specials, perfect linking of joints with jack to correct position including
cost of jointing materials, i.e, rubber rings with all leads and lifts as directed and giving necessary hydraulic test as per ISS to the required pressure and commissioning etc. complete. (Contractor will make his own arrangements for procuring water for testing). 250 mm dia | m | 215.27 | 215.27 | 30.0 | False | None | None | False | None | False | 6458.1 | 0 |
| 3255377 | 112778 | None | code19 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications. | Cum | 164.8 | 164.8 | 18.0 | False | None | None | False | None | False | 2966.4 | 0 |
| 3255378 | 112778 | None | code01 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth | Cum | 97.85 | 97.85 | 59.27 | False | None | None | False | None | False | 5799.5695 | 0 |
| 3255379 | 112778 | None | code02 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with
vibratory roller in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density. Mechanical means, (i) Grading-I (63 mm to 45 mm), (c) Using Screening Type B (11.2mm agg) | Cum | 2559.55 | 2559.55 | 29.64 | False | None | None | False | None | False | 75865.062 | 0 |
| 3255380 | 112778 | None | code03 | Sand Filling in Wells complete as per Drawing and Technical Specifications. | Cum | 2658.43 | 2658.43 | 19.76 | False | None | None | False | None | False | 52530.5768 | 0 |
| 3255381 | 112778 | None | code04 | Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. | Sqm | 824.0 | 824.0 | 197.57 | False | None | None | False | None | False | 162797.68 | 0 |
| 3255382 | 112778 | None | code09 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 342.99 | 342.99 | 119.99 | False | None | None | False | None | False | 41155.3701 | 0 |
| 3255383 | 112778 | None | code10 | Providing Colour washing such as green, blue or buff to give an even shade :New work (two coats) with a base coat of whiting with colour of approved quality, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 33.99 | 33.99 | 119.99 | False | None | None | False | None | False | 4078.4601 | 0 |
| 3255384 | 112778 | None | code01 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe ...... mm dia mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thick | m | 67.98 | 67.98 | 276.52 | False | None | None | False | None | False | 18797.8296 | 0 |
| 3255385 | 112778 | None | code02 | Open Conduit System Supplying heavy gauge PVC conduit pipe ....... dia mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25 mm dia 2 mm thick | m | 83.43 | 83.43 | 60.0 | False | None | None | False | None | False | 5005.8 | 0 |
| 3255386 | 112778 | None | code03 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 200 x 90 x 65 mm | No | 184.37 | 184.37 | 13.0 | False | None | None | False | None | False | 2396.81 | 0 |
| 3255387 | 112778 | None | code04 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3m upto 6m from tapping point to out let via switch box | Point | 390.37 | 390.37 | 20.0 | False | None | None | False | None | False | 7807.4 | 0 |
| 3255388 | 112778 | None | code05 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6m upto 10m from tapping point to out let via switch box | Point | 571.65 | 571.65 | 25.0 | False | None | None | False | None | False | 14291.25 | 0 |
| 3255389 | 112778 | None | code06 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:confirming to latest amendments. 1.5 mm2 | m | 26.78 | 26.78 | 400.0 | False | None | None | False | None | False | 10712.0 | 0 |
| 3255390 | 112778 | None | code07 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:confirming to latest amendments. 2.5 mm2 | m | 43.26 | 43.26 | 250.0 | False | None | None | False | None | False | 10815.0 | 0 |
| 3255391 | 112778 | None | code08 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:confirming to latest amendments. 4 mm2 | m | 64.89 | 64.89 | 200.0 | False | None | None | False | None | False | 12978.0 | 0 |
| 3255392 | 112778 | None | code09 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:confirming to latest amendments. 6 mm2 | m | 94.76 | 94.76 | 150.0 | False | None | None | False | None | False | 14214.0 | 0 |
| 3255393 | 112778 | None | code10 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6 Way | Each | 226.6 | 226.6 | 10.0 | False | None | None | False | None | False | 2266.0 | 0 |
| 3255394 | 112778 | None | code11 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way | Each | 268.83 | 268.83 | 10.0 | False | None | None | False | None | False | 2688.3 | 0 |
| 3255395 | 112778 | None | code12 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module | Each | 241.02 | 241.02 | 10.0 | False | None | None | False | None | False | 2410.2 | 0 |
| 3255396 | 112778 | None | code13 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module | Each | 292.52 | 292.52 | 10.0 | False | None | None | False | None | False | 2925.2 | 0 |
| 3255397 | 112778 | None | code14 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch | Each | 105.06 | 105.06 | 74.0 | False | None | None | False | None | False | 7774.44 | 0 |
| 3255398 | 112778 | None | code15 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module | Each | 367.71 | 367.71 | 3.0 | False | None | None | False | None | False | 1103.13 | 0 |
| 3255399 | 112778 | None | code16 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16A One Way Switch | Each | 185.4 | 185.4 | 12.0 | False | None | None | False | None | False | 2224.8 | 0 |
| 3255400 | 112778 | None | code17 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32A DP Switch | Each | 335.78 | 335.78 | 3.0 | False | None | None | False | None | False | 1007.34 | 0 |
| 3255401 | 112778 | None | code18 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal Socket | Each | 243.08 | 243.08 | 8.0 | False | None | None | False | None | False | 1944.64 | 0 |
| 3255402 | 112778 | None | code19 | Extra for supplying 4 mm thick white plastic plate and covering for junction boxes of size mm conduit using necessary machine screws. 80 mm | No | 15.45 | 15.45 | 17.0 | False | None | None | False | None | False | 262.65 | 0 |
| 3255403 | 112778 | None | code20 | Extra for supplying 4 mm thick white plastic plate and covering for junction boxes of size mm conduit using necessary machine screws. 110 mm | No | 21.63 | 21.63 | 9.0 | False | None | None | False | None | False | 194.67 | 0 |
| 3255404 | 112778 | None | code21 | Supplying of feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' -
20/22 W | Each | 710.7 | 710.7 | 41.0 | False | None | None | False | None | False | 29138.7 | 0 |
| 3255405 | 112778 | None | code22 | Supply of roundsquare recesssurface mounted rollingtypeLED Downlight withGU10 LED Lamp Rib Fabricated from diecast iniumwith whitepowder coated prewired to mainsconnectorswivelling unit of aluminiumdiecasteyeball& LED Lamp positionretainedby circularwire spring, with Lifeof 25000burninghours&70% lumen maintenance withCRI80. Power Input:220 240V AT50 60Hz & Power factor 0.9 along with CE approved. 2years Warrantyagainst any manufacturing defect working under standard electrical condition LED square or round down light 1518W | Each | 1363.72 | 1363.72 | 18.0 | False | None | None | False | None | False | 24546.96 | 0 |
| 3255406 | 112778 | None | code23 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. On wall/ ceiling / Rafter / Girders | Each | 125.66 | 125.66 | 59.0 | False | None | None | False | None | False | 7413.94 | 0 |
| 3255407 | 112778 | None | code24 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE star rated and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturerWarranty 48" Sweep BEE Star Rated
(1200 mm) | Each | 2757.31 | 2757.31 | 12.0 | False | None | None | False | None | False | 33087.72 | 0 |
| 3255408 | 112778 | None | code25 | Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clA and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. | Each | 176.13 | 176.13 | 12.0 | False | None | None | False | None | False | 2113.56 | 0 |
| 3255409 | 112778 | None | code26 | Extra length of GI pipe of class B 19mm dia for down rod. | m | 202.91 | 202.91 | 4.8 | False | None | None | False | None | False | 973.968 | 0 |
| 3255410 | 112778 | None | code27 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 12" Sweep (300 mm) | Each | 3058.07 | 3058.07 | 2.0 | False | None | None | False | None | False | 6116.14 | 0 |
| 3255411 | 112778 | None | code28 | Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame | Each | 728.21 | 728.21 | 2.0 | False | None | None | False | None | False | 1456.42 | 0 |
| 3255412 | 112778 | None | code29 | Supplying & fixing of retrofit type - LED bulb W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, C 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322IEC 60598 LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF0.95, power loss should 5% of lamp Wage short circuit AND open circuit protection to be integrated in the circuit THD less than 20% Life as per LM 79. The operating input voltage should be between 130 to 275 VBIS Approved and Tested by ABLCPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition 9W 6500K | Each | 158.62 | 158.62 | 5.0 | False | None | None | False | None | False | 793.1 | 0 |
| 3255413 | 112778 | None | code30 | Supplying & Fixing of 70-150 W lamp holder 2 Pin | Each | 64.89 | 64.89 | 77.0 | False | None | None | False | None | False | 4996.53 | 0 |
| 3255414 | 112778 | None | code31 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts | No | 4383.68 | 4383.68 | 1.0 | False | None | None | False | None | False | 4383.68 | 0 |