createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1720246447492
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd6250.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose20-07-2024 17:30:00
tenderQueryClose19-07-2024 17:30:00
technicalBidOpen22-07-2024 11:30:00
publishedDate06-07-2024 12:50:39
publishedByPostCMC_MCOM_CMJ
publishedByUserKPE12757 - RAMADAS S V
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonManjunath
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9448872062
tenderSupplierListNone
tenderSchedule
createdTs1720246447525
version4
createdDateNone
modifiedDateNone
tenderNumberDMA/2023-24/WS/WORK_INDENT16381
titleConstruction of Mini water suppy tank and Drilling of Borewell & fixing of Motor in Ward no 10 near to Basaveswara Temple in chamarajanagara CMC Limits.
descriptionConstruction of Mini water suppy tank and Drilling of Borewell & fixing of Motor in Ward no 10 near to Basaveswara Temple in chamarajanagara CMC Limits.
categoryWORKS
categoryTextWorks
ecv247886.41
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2456
locationNameDMA City Municipal Council Chamarajanagara
provisionalAmount250000.0
groupOverheadTotal37813.18
fileNumberCMC/JE/wardno10/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17202464480000NoneNoneWater supply/sewage linesConstruction of Mini water suppy tank and Drilling of Borewell & fixing of Motor in Ward no 10 near to Basaveswara Temple in chamarajanagara CMC Limits.210073.23
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3463279123529None12.4Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test.etc.complete.Each5288.05288.01.0FalseNoneNoneFalseNoneFalse5288.00
3463280123529None12.1.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth.Borewell depth of 0 to 50 MtrsMtr370.0370.050.0FalseNoneNoneFalseNoneFalse18500.00
3463281123529None12.1.2Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth.Borewell depth of 50 to 100 Mtrsm464.0464.050.0FalseNoneNoneFalseNoneFalse23200.00
3463282123529None12.32Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty.m1993.01993.018.0FalseNoneNoneFalseNoneFalse35874.00
3463283123529None12.34Providing and laying at site of work MS casing caps as per IS 1239 (part II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in chargeEach164.0164.01.0FalseNoneNoneFalseNoneFalse164.00
3463284123529None13.13.6Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. 7.50 HP - 90 LPM @ 165 m = 16 STG Outlet Dia - 2.00Each40810.040810.01.0FalseNoneNoneFalseNoneFalse40810.00
3463285123529None13.22.3Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments.1x3x4 Sqmm135.0135.070.0FalseNoneNoneFalseNoneFalse9450.00
3463286123529None13.27.1Supply and delivery of galvanized mild steel tubes of 6mtr standard length heavy duty (C Class) as per IS 1239 (Part-I) 1990 with latest amendments with ISI Mark (one end fitted with Heavy Duty collar and other end fitted with protective cover) 50 mmEach3050.03050.08.0FalseNoneNoneFalseNoneFalse24400.00
3463287123529None13.32Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. Job6500.06500.01.0FalseNoneNoneFalseNoneFalse6500.00
3463288123529None13.24.1Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 50 mmEach1250.01250.01.0FalseNoneNoneFalseNoneFalse1250.00
3463289123529None13.25.1Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments. Size 50 mmEach1250.01250.01.0FalseNoneNoneFalseNoneFalse1250.00
3463290123529None5.42.1Fabricating supplying and mounting MS box made out .SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.14 SWGcm0.50.525000.0FalseNoneNoneFalseNoneFalse12500.00
3463291123529None13.34Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer incharge of work.Each1450.01450.01.0FalseNoneNoneFalseNoneFalse1450.00
3463292123529None5.6.6Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.20" x 20" x 2.5"Each326.13326.131.0FalseNoneNoneFalseNoneFalse326.130
3463293123529None3.8Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screws.cm0.410.412500.0FalseNoneNoneFalseNoneFalse1025.00
3463294123529None13.23.3Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete.6 to 15 HP pumpsEach15900.015900.01.0FalseNoneNoneFalseNoneFalse15900.00
3463295123529None5.7.3Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.63 AEach401.0401.03.0FalseNoneNoneFalseNoneFalse1203.00
3463296123529None5.7.1Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.16 AEach157.0157.01.0FalseNoneNoneFalseNoneFalse157.00
3463297123529None1.1.2Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.25 mm dia 2 mm thickm81.081.030.0FalseNoneNoneFalseNoneFalse2430.00
3463298123529None2.1.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Medium point above 3m upto 6m from tapping point to out let via switchPoint394.0394.03.0FalseNoneNoneFalseNoneFalse1182.00
3463299123529None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854.6A 3/5 WayEach147.0147.03.0FalseNoneNoneFalseNoneFalse441.00
3463300123529None3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.32A DP Switch.Each326.0326.01.0FalseNoneNoneFalseNoneFalse326.00
3463301123529None2.3.2Wiringforlighting/power circuit using one of FRLS PVC insulated 1100 Vgrade ,multistrand copper wire with low conductorresistance singlecore in open orconcealed system of wiring with specified IS-694:2010.1.5mm2m26.026.010.0FalseNoneNoneFalseNoneFalse260.00
3463302123529None2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.5 mm2m42.042.010.0FalseNoneNoneFalseNoneFalse420.00
3463303123529None1.1Wiring for lighting/power circuit using one of FRLS PVC insulated1100V grade,multistrand copper wire with low conductor resistance single corein open or concealed system o fwiring with specifiedIS-694:2010.4 mm2m63.063.010.0FalseNoneNoneFalseNoneFalse630.00
3463304123529None3.12.2Supplying.way plastic gangbox and fixing using necessary wooden/ rawl/phill plugs and screws. 2 to 4 Way Gang BoxNo32.032.03.0FalseNoneNoneFalseNoneFalse96.00
3463305123529None3.14.1Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board.6A SP SwitchNo55.055.03.0FalseNoneNoneFalseNoneFalse165.00
3463306123529None3.14.1Supplying & Fixing of 70-150 W lamp holder 2 PinNo63.063.02.0FalseNoneNoneFalseNoneFalse126.00
3463307123529None32.031.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975.10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm)Km118004.0118004.00.025FalseNoneNoneFalseNoneFalse2950.10
3463308123529None22(c)Laying of 11 kV cables in existing trench/G.I. pipe/stoneware pipe/RCC hume pipe using wooden/aluminium rollers as directed by KPTCL staff (Cables of sizes 3C x 95 to 3C x 150 Sq mm)m72.072.025.0FalseNoneNoneFalseNoneFalse1800.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17202464490000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17202464490000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17202464490000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17202464490000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17202464490000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneDepartment Registration DetailsNoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneScanned Copy of FD in Favour of Muncipal Commissioner, CMC, Chamarajanagara for Negitive Premium Amount (Difference Amount)OthersScanned Copy of FD
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned Copy of FD in Favour of Muncipal Commissioner, CMC, Chamarajanagara for Negitive Premium Amount (Difference Amount)
NoneNoneNoneNoneGST registrationOthersGST registration
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneContractor Licenced certifiacteOthersContractor Licenced certifiacte
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneturnoverOthersturnover
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateFalseTechnical Bid
Company Registration CertificateFalseTechnical Bid
Reserved Category CertificateFalseTechnical Bid
Small Scale Industries CertificateFalseTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone