1719640048000 | 0 | None | None | Other Works | Construction of Material Recovery Facility Centre in Solid Waste Management Sire at Indavara, chikkamagalur | 22028321.28 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3406735 | 120302 | None | NO1 | Earth work in surface excavation by mechanical means for lowering and leveling the ground for all works other than foundation in all kinds of soils and upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumpsand other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ,Item Code -1.12 , Page No - 8 , VOL-1 ---- MRF work | Cum | 97.85 | 97.85 | 630.0 | False | None | None | False | None | False | 61645.5 | 0 | 3406736 | 120302 | None | NO2 | Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenaces required to ---- MRF work | Cum | 105.06 | 105.06 | 620.016 | False | None | None | False | None | False | 65138.88096 | 0 | 3406737 | 120302 | None | NO3 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20percentage E.C. or Lindane 20percentage E.C. at3.19 lorm2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ,Item Code -4.1 , Page No - 5 , VOL-2 ---- MRF work | Sqm | 121.54 | 121.54 | 1500.0 | False | None | None | False | None | False | 182310.0 | 0 | 3406738 | 120302 | None | NO4 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The graniteortraporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ,Item Code -2.1.3 , Page No - 15 , VOL-1 ---- MRF work | Cum | 6168.67 | 6168.67 | 210.4665 | False | None | None | False | None | False | 1298298.384555 | 0 | 3406739 | 120302 | None | NO5 | Providing and laying in position Cement Concrete for all Foundation works. The graniteortraporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ,Item Code -2.2.3 , Page No - 15 , VOL-1 ---- MRF work | Cum | 7048.17 | 7048.17 | 62.208 | False | None | None | False | None | False | 438452.55936 | 0 | 3406740 | 120302 | None | NO6 | Providing and laying in position Cement Concrete for all Foundation works. The graniteortraporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ,Item Code -2.2.3 , Page No - 15 , VOL-1 ---- MRF work | Cum | 6721.86 | 6721.86 | 83.3625 | False | None | None | False | None | False | 560351.05425 | 0 | 3406741 | 120302 | None | NO7 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ,Item Code -1.9 , Page No - 7 , VOL-1 ---- MRF work | Cum | 273.98 | 273.98 | 422.1495 | False | None | None | False | None | False | 115660.52001 | 0 | 3406742 | 120302 | None | NO8 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The graniteortraporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead and lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ,Item Code -2.4.3 , Page No - 16 , VOL-1 ---- MRF work | Cum | 11094.34 | 11094.34 | 13.608 | False | None | None | False | None | False | 150971.77872 | 0 | 3406743 | 120302 | None | NO9 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ,Item Code -2.5.2 , Page No - 16 , VOL-1 ---- MRF work | Cum | 11982.09 | 11982.09 | 35.64 | False | None | None | False | None | False | 427041.6876 | 0 | 3406744 | 120302 | None | NO10 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ,Item Code -2.5.2 , Page No - 16 , VOL-1 ---- MRF work | Cum | 7753.12 | 7753.12 | 78.0 | False | None | None | False | None | False | 604743.36 | 0 | 3406745 | 120302 | None | NO11 | Providing Size Stone masonry with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) , Item Code -5.4 , Page No - 9 , VOL-2 ---- MRF work | Cum | 6580.67 | 6580.67 | 42.0129 | False | None | None | False | None | False | 276473.030643 | 0 | 3406746 | 120302 | None | NO12 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The graniteortraporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead and lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ,Item Code -2.4.3 , Page No - 16 , VOL-1 ---- MRF work | Cum | 9789.12 | 9789.12 | 36.879 | False | None | None | False | None | False | 361012.95648 | 0 | 3406747 | 120302 | None | NO13 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The graniteortraporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead and lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ,Item Code -2.4.3 , Page No - 16 , VOL-1 ---- MRF work | Cum | 6526.08 | 6526.08 | 227.7 | False | None | None | False | None | False | 1485988.416 | 0 | 3406748 | 120302 | None | NO14 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ,Item Code -2.5.2 , Page No - 16 , VOL-1 ---- MRF work | Cum | 11277.29 | 11277.29 | 16.191 | False | None | None | False | None | False | 182590.60239 | 0 | 3406749 | 120302 | None | NO15 | Supplying, fitting and placing TMT FE 550 or 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapingorwelding joints, tying with binding wire or soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings
,Item Code -2.11a , Page No - 18 , VOL-1 ---- MRF work | Tonne | 92140.71 | 92140.71 | 37.361 | False | None | None | False | None | False | 3442469.06631 | 0 | 3406750 | 120302 | None | NO16 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kgorm3 and minimum compressive strength of 4.00 Normm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specification-- Item code 6.32 Vol 2 Page 17 ---- MRF work | Sqm | 1349.3 | 1349.3 | 407.025 | False | None | None | False | None | False | 549198.8325 | 0 | 3406751 | 120302 | None | NO17 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. , Item Code -8.2.2 , Page No - 41 , VOL-2 ---- MRF work | Sqm | 287.37 | 287.37 | 921.1199 | False | None | None | False | None | False | 264702.225663 | 0 | 3406752 | 120302 | None | NO18 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (0.05 percentage) total coated thickness with zinc coating 120 gorm2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer in-charge. The sheet shall be fixed using self drillingorself tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontalor vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required Vol 2, Page No 26 , item no 7.38 ---- MRF work | Sqm | 585.04 | 585.04 | 1965.0 | False | None | None | False | None | False | 1149603.6 | 0 | 3406753 | 120302 | None | NO19 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 percentage) total coated thickness, Zinc coating 120 gorm2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drillingor self tapping screws complete : Ridges plain (500 - 600mm) Vol 2, Page No 26 , item no 7.39.1 ---- MRF work | Mtr | 464.53 | 464.53 | 63.0 | False | None | None | False | None | False | 29265.39 | 0 | 3406754 | 120302 | None | NO20 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Chargee. VOL2 , page No 82, 11.16.1 ---- MRF work | Kg | 140.08 | 140.08 | 61500.5968 | False | None | None | False | None | False | 8615003.599744 | 0 | 3406755 | 120302 | None | NO21 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ,Item Code -8.40 , Page No - 48 , VOL-2 ---- MRF work | Sqm | 118.45 | 118.45 | 1683.28 | False | None | None | False | None | False | 199384.516 | 0 | 3406756 | 120302 | None | NO22 | Construction of Embankment by excavating the available approved Gravelor Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usageand all other appurtenaces required to complete the work. ,Item Code -1.8 , Page No - 7 , VOL-1 ---- MRF work | Cum | 488.22 | 488.22 | 1800.0 | False | None | None | False | None | False | 878796.0 | 0 | 3406757 | 120302 | None | NO23 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls at1.25 Lor10 Sqm over and including one coat of Special primer applied at0.75 Lor10 Sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50percentage at60 degree angle with 10 years life) , Item Code -8.33.1 , Page No - 46 , VOL-2 ---- MRF work | Sqm | 162.74 | 162.74 | 1180.12 | False | None | None | False | None | False | 192052.7288 | 0 | 3406758 | 120302 | None | NO24 | Supplying heavy gauge PVC conduit pipe.......dia.......mm thick confirming to IS2509 with suitable size bends ,junction boxes,adhesive paste etc,and fixing using inverted wood plugs in case of RCC ceiling and RCC wallorstone structure or rawl plug s in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws item code 1.1.2 , Vol 6 ---- MRF work | Mtr | 83.43 | 83.43 | 350.0 | False | None | None | False | None | False | 29200.5 | 0 | 3406759 | 120302 | None | NO25 | Supplying and flush mounting teak wooden box without front plank ,made of not less than12mm thick wood, after due groove cutting, finishing with necessary cement plastering complete. 12" x 12" x 3" (300 x 300 x 76 mm) item code 1.6.1 , Vol 6 ---- MRF work | Each | 123.6 | 123.6 | 8.0 | False | None | None | False | None | False | 988.8 | 0 | 3406760 | 120302 | None | NO26 | Supplying and fixing superior quality modular switch mounting poly carbonate plate with necessary supporting back plate with required nos. of machine screws,bolts nuts etc.,complete on the existing metal or PVC box. Item Code 3.5.6 , Vol 6 ---- MRF work | Each | 354.32 | 354.32 | 8.0 | False | None | None | False | None | False | 2834.56 | 0 | 3406761 | 120302 | None | NO27 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch. Item Code 3.6.1 , Vol 6 ---- MRF work | Each | 105.06 | 105.06 | 30.0 | False | None | None | False | None | False | 3151.8 | 0 | 3406762 | 120302 | None | NO28 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32A DP Switch. Item Code 3.6.9 , Vol 6 ---- MRF work | Each | 335.78 | 335.78 | 8.0 | False | None | None | False | None | False | 2686.24 | 0 | 3406763 | 120302 | None | NO29 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6or16A Universal Socket. Item Code 3.6.10 , Vol 6 ---- MRF work | Each | 243.08 | 243.08 | 10.0 | False | None | None | False | None | False | 2430.8 | 0 | 3406764 | 120302 | None | NO30 | Supplying and fixing of Porcelain fuse channel with cut out on existing woodenorpanel using necessary nuts, bolts and washers. 32A. Item Code 5.7.2 , Vol 6 ---- MRF work | Each | 248.23 | 248.23 | 8.0 | False | None | None | False | None | False | 1985.84 | 0 | 3406765 | 120302 | None | NO31 | Supplying and fixing regular MCCB distribution Panel confirming to ISorIEC61439-3 and IK09 tested as per IS orIEC62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket ,with suitable earthing system, onwall orwoodboardor flush mounting using required clA, bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB' sasanin comer for 3phase Double door with necessary busbar completely wired to use on 440V 3pase 4wire powder coated painting etc., complete with a provision for fixing of singleorthree phase suitable capacity MCB's as outgoing s confirming to ISorIEC 60898 - 2. 12 Way. Item Code 5.17.3 , Vol 6 ---- MRF work | Each | 15994.87 | 15994.87 | 6.0 | False | None | None | False | None | False | 95969.22 | 0 | 3406766 | 120302 | None | NO32 | Supplying and fixing miniature circuitbreaker s on existing MCB distribution boards using necessary fixing materials and 'C' Type curve,indicator ONorOFF ,energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.. Item Code 5.18.5 , Vol 6 ---- MRF work | Each | 1091.8 | 1091.8 | 6.0 | False | None | None | False | None | False | 6550.8 | 0 | 3406767 | 120302 | None | NO33 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990. 2C x 4 mm2. item code 2.5.14 , Vol 6 ---- MRF work | Each | 126.69 | 126.69 | 650.0 | False | None | None | False | None | False | 82348.5 | 0 | 3406768 | 120302 | None | NO34 | Earth work excavation for pipelinesorcables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage and other appurtenances required to complete the work.. item code 1.6.1 , Vol 1 ---- MRF work | Cum | 498.52 | 498.52 | 135.0 | False | None | None | False | None | False | 67300.2 | 0 | 3406769 | 120302 | None | NO35 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975.16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm).. item code 32.05 , Vol 6 ---- MRF work | Km | 146097.26 | 146097.26 | 0.5 | False | None | None | False | None | False | 73048.63 | 0 | 3406770 | 120302 | None | NO36 | Laying of cable in Existing TrenchorGI pipeorStone WareorRCC Hume pipe using Woodenor Aluminum Rollers as directed by the departmental staff ,2.5 to 25 Sqmm.. item code 21.05 , Vol 6 ---- MRF work | Km | 21512.58 | 21512.58 | 0.5 | False | None | None | False | None | False | 10756.29 | 0 | 3406771 | 120302 | None | NO37 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonateorclear glass material,delivering superior light output. Rated life Burning Hrs 50000 hr atLumen Maintenance of 70percentage, CCTgreater than 5500K, IP 66optical and electrical compartment and impact resistance of complete luminairegreater than IK08. Power Factorgreater than0.9 with mains,Surge protection- Min 5KV along with Over voltageorOverload, short circuitor miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm.Universal Voltage driver to operate wide voltage range from 100V to 270V 50or60Hz application. Compliance to IS 10322orIEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency 130lmorw,nominal CRIgreater than75. Luminaire manufacturer should have inhouse facility accredited by NABLorCPRI and any Government certified agency and Design and Development facility certified by ISO 9001:2008 . Housing with supplier word mark orname shall be Engraved or Embossing on the die cast housingor Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and CreeorNichiaorLumiledsorOsram make LED Source... item code 11.9.1 , Vol 6 ---- MRF work | Each | 6971.04 | 6971.04 | 15.0 | False | None | None | False | None | False | 104565.6 | 0 | 3406772 | 120302 | None | NO38 | Fixing halogenormetal halide or SVL or IL or LED floodlight fitting over existing pole or wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires... item code 13.5 , Vol 6 ---- MRF work | Nos | 166.86 | 166.86 | 15.0 | False | None | None | False | None | False | 2502.9 | 0 | 3406773 | 120302 | None | NO39 | Earthing: Providing and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia.... item code 12.56 , Vol 6 ---- MRF work | Nos | 3615.3 | 3615.3 | 3.0 | False | None | None | False | None | False | 10845.9 | 0 |
|