| 1720336806000 | 0 | None | None | Other Works | REPAIRS AND CONSTRUCTIONS OF SWD IN FRONT OF INDIRA CANTEEN AT TOWN PANCHAYATH, GUDIBANDE | 423372.01 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3472709 | 123965 | None | GUD1 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m PWD SR 2023-24 Vol:1 P.NO.5 I.No:1.4.1 | Cum | 191.58 | 191.58 | 33.75 | False | None | None | False | None | False | 6465.825 | 0 | | 3472710 | 123965 | None | GUD2 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of
all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse
aggregates [PWD SR 2023-24 Vol:I P.NO.15 I.No:2.1.2] | Cum | 5833.92 | 5833.92 | 4.05 | False | None | None | False | None | False | 23627.376 | 0 | | 3472711 | 123965 | None | GUD3 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates[PWD SR 2023-24 Vol:I P.NO.15/16 I.No:2.3.1] | Cum | 6828.84 | 6828.84 | 21.85 | False | None | None | False | None | False | 149210.154 | 0 | | 3472712 | 123965 | None | GUD4 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Foundations of Bridges[PWD SR 2023-24 Vol:I P.NO.18 I.No:2.11.B] | t | 91507.26 | 91507.26 | 0.57 | False | None | None | False | None | False | 52159.1382 | 0 | | 3472713 | 123965 | None | GUD5 | Water purification plants: Providing, Installation and Commissioning of automatic Water purification plant (RO+UF) with all accessories piping, product water tank on single phase power supply as per the enclosed detailed Technical Specifications including cost of material, loading and unloading and as directed by the Engineer in charge. (Ref- detailed specification enclosed seperatly). Note:- 1.The above rates mentioned are only for the preparation of estimate purpose. 2. All items are to be of BSI /NFS standards,with BSI / NFS mark . 3. Tenders to be invited for procurement. 4. No direct payment should be made under any situationor condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge. Note : Refer the ANNEXURE : F for Detailed Specification of Each componen 50 LPH : Cabin Type [PWD SR 2023-24 Vol:V P.NO.247 I.No:21.1.2] | No | 47520.0 | 47520.0 | 1.0 | False | None | None | False | None | False | 47520.0 | 0 | | 3472714 | 123965 | None | GUD6 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. 110mm(weight of pipe -1.315 kg) [PWD SR 2023-24 Vol:V P.NO.120 I.No:10.14.4] | m | 304.56 | 304.56 | 50.0 | False | None | None | False | None | False | 15228.0 | 0 | | 3472715 | 123965 | None | GUD7 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid [PWD SR 2023-24 Vol:II P.NO.131 I.No:14.3.1] | m | 6455.16 | 6455.16 | 2.0 | False | None | None | False | None | False | 12910.32 | 0 | | 3472716 | 123965 | None | GUD8 | Old Terrace Screed Repair with UV Resistant Waterproof coating Providing and Applying high elastic & resilient Acrylic polymer Waterproofing coating which is single component, cold applied, water based acrylic and UV resistant water proofing treatment to the Existing Roof screed surface applied 1.5 l/m2 in 3 coats to achieve 1mm DFT, having tensile strength 1.2 N/mm2 confirming to ASTM D 412; Elongation at break 100% and Crack bridging ability up to 2 mm, including surface preparation, priming the surface with 1 coat of Efflorescence resistant penetrating primer dilute with water in the ratio 2:1 spreading at the rate of 0.125 lm2 in the SSD condition and spreading 45 gsm glass fibre mesh of 2.5 mm x 2.5 mm sandwiched between the first and second coat completely as per specification. The finished cost to include surface preparation, making coving at Junction, treatment of cracks completely as per specification. PWD SR 2023-24 Vol:II P.NO.150 AND 151 I.No:15.8 | m | 745.2 | 745.2 | 156.0 | False | None | None | False | None | False | 116251.2 | 0 |
|