3472533 | 123950 | None | code01 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out,shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work | Cum | 242.0 | 242.0 | 46.09 | False | None | None | False | None | False | 11153.78 | 0 |
3472534 | 123950 | None | code02 | Providing and laying in position Cement Concrete for levelling course forall works in foundation. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5664.0 | 5664.0 | 20.23 | False | None | None | False | None | False | 114582.72 | 0 |
3472535 | 123950 | None | code03 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6512.69 | 6512.69 | 5.76 | False | None | None | False | None | False | 37513.0944 | 0 |
3472536 | 123950 | None | code04 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11016.0 | 11016.0 | 4.68 | False | None | None | False | None | False | 51554.88 | 0 |
3472537 | 123950 | None | code05 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 9720.0 | 9720.0 | 5.44 | False | None | None | False | None | False | 52876.8 | 0 |
3472538 | 123950 | None | code06 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregate | Cum | 9484.5 | 9484.5 | 5.3 | False | None | None | False | None | False | 50267.85 | 0 |
3472539 | 123950 | None | code07 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregate Slab | Cum | 10116.8 | 10116.8 | 13.6 | False | None | None | False | None | False | 137588.48 | 0 |
3472540 | 123950 | None | code08 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with | Cum | 6618.0 | 6618.0 | 9.85 | False | None | None | False | None | False | 65187.3 | 0 |
3472541 | 123950 | None | code09 | Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6205.0 | 6205.0 | 11.77 | False | None | None | False | None | False | 73032.85 | 0 |
3472542 | 123950 | None | code10 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification | MT | 89457.0 | 89457.0 | 3.071 | False | None | None | False | None | False | 274722.447 | 0 |
3472543 | 123950 | None | code11 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 7978.0 | 7978.0 | 26.17 | False | None | None | False | None | False | 208784.26 | 0 |
3472544 | 123950 | None | code12 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 433.0 | 433.0 | 50.85 | False | None | None | False | None | False | 22018.05 | 0 |
3472545 | 123950 | None | code13 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications | Cum | 124202.0 | 124202.0 | 0.083 | False | None | None | False | None | False | 10308.766 | 0 |
3472546 | 123950 | None | code14 | Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) | Sqm | 7444.0 | 7444.0 | 2.52 | False | None | None | False | None | False | 18758.88 | 0 |
3472547 | 123950 | None | code15 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 255.0 | 255.0 | 256.38 | False | None | None | False | None | False | 65376.9 | 0 |
3472548 | 123950 | None | code16 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 333.0 | 333.0 | 233.16 | False | None | None | False | None | False | 77642.28 | 0 |
3472549 | 123950 | None | code17 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. | Kg | 183.0 | 183.0 | 302.4 | False | None | None | False | None | False | 55339.2 | 0 |
3472550 | 123950 | None | code18 | PProviding & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimumTiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. oextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 5023.0 | 5023.0 | 14.4 | False | None | None | False | None | False | 72331.2 | 0 |
3472551 | 123950 | None | code19 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 137.0 | 137.0 | 256.5 | False | None | None | False | None | False | 35140.5 | 0 |
3472552 | 123950 | None | code20 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 174.0 | 174.0 | 233.16 | False | None | None | False | None | False | 40569.84 | 0 |
3472553 | 123950 | None | code21 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm | Sqm | 1145.0 | 1145.0 | 100.51 | False | None | None | False | None | False | 115083.95 | 0 |
3472554 | 123950 | None | code22 | Providing and applying white cement based putty of average thickness 1 mm, of aproved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 100.0 | 100.0 | 276.38 | False | None | None | False | None | False | 27638.0 | 0 |
3472555 | 123950 | None | code23 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 115.0 | 115.0 | 28.8 | False | None | None | False | None | False | 3312.0 | 0 |
3472556 | 123950 | None | code24 | Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 4.0 | 4.0 | 1000.0 | False | None | None | False | None | False | 4000.0 | 0 |
3472557 | 123950 | None | code25 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existingPVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. I. Point wiring using class A Materials a) Short point up to 3Mtr from tapping point to out let via switch and as per directions of Engineer-in-charge. | Each | 285.0 | 285.0 | 2.0 | False | None | None | False | None | False | 570.0 | 0 |
3472558 | 123950 | None | code26 | b) Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch and as per directions of Engineer-in-charge. | Each | 394.0 | 394.0 | 3.0 | False | None | None | False | None | False | 1182.0 | 0 |
3472559 | 123950 | None | code27 | c) Long point above 6Mtr up to 10Mtr from tapping point to out let via switch and as per directions of Engineer-in-charge. | Each | 570.0 | 570.0 | 3.0 | False | None | None | False | None | False | 1710.0 | 0 |
3472560 | 123950 | None | code28 | Supplying 6 A flush type socket and 6 Amps flush type SP switch either surface / flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 and as per directions of Engineer-in-charge. | Each | 147.0 | 147.0 | 3.0 | False | None | None | False | None | False | 441.0 | 0 |
3472561 | 123950 | None | code29 | Supply and fixing of Bakelite DP/ Socket/ Switch with / without neon indicator over existing wood board or flush mounting in plastic plates/ nitches as per IS 1293 and IS 3854 a) 32 Amps Flush / projected type DP switch and as per directions of Engineer-in-charge. | Each | 232.0 | 232.0 | 3.0 | False | None | None | False | None | False | 696.0 | 0 |
3472562 | 123950 | None | code30 | b) 16 Amps Flush type Universal Socket and as per directions of Engineer-in-charge. | Each | 236.0 | 236.0 | 3.0 | False | None | None | False | None | False | 708.0 | 0 |
3472563 | 123950 | None | code31 | Supplying and fixing ofs lim patty fitting, made out of CRCA Sheetmetal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube. 1 x 4' Tube light fitting and as per directions of Engineer-in-charge. | Each | 269.0 | 269.0 | 10.0 | False | None | None | False | None | False | 2690.0 | 0 |
3472564 | 123950 | None | code32 | Fixing all type sand all capacitie soffluorescent /falseceiling/ spotlight/ CFL/ LED fitting sindoor onthe wall /ceiling/ rafters/ girdersusing 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall/ ceiling / Rafter / Girders and as per directions of Engineer-in-charge. | Each | 122.0 | 122.0 | 5.0 | False | None | None | False | None | False | 610.0 | 0 |
3472565 | 123950 | None | code33 | Supply ingand fixing of PVC casing and capping on the wall or ceiling using necessary material slike bends, junction box, elbows, screwsatan interval of 300 mm as required. and as per directions of Engineer-in-charge. | Mtr | 35.0 | 35.0 | 10.0 | False | None | None | False | None | False | 350.0 | 0 |
3472566 | 123950 | None | code34 | Wiring for lighting/ power circuit using one of FRLSPV Cinsulated 1100V grade, multi strand copper wirewith low conduct or resistancesing lecore inopenor concealedsy stem of wiring with specified IS-694:2010 1 mm2 I. Group A Materials a.1 sqmm and as per directions of Engineer-in-charge. | Mtr | 19.0 | 19.0 | 40.0 | False | None | None | False | None | False | 760.0 | 0 |
3472567 | 123950 | None | code35 | b.1.5 sqmm and as per directions of Engineer-in-charge. | Mtr | 26.0 | 26.0 | 40.0 | False | None | None | False | None | False | 1040.0 | 0 |
3472568 | 123950 | None | code36 | c. 2.5 sqmm and as per directions of Engineer-in-charge. | Mtr | 42.0 | 42.0 | 40.0 | False | None | None | False | None | False | 1680.0 | 0 |
3472569 | 123950 | None | code37 | Supplying of LED floodlight with 110 W system power consumption pressure die cast aluminum housing with powder coating with IP 65 protection. 1, 200 - 275 V voltage with electronic Driver, PF 0.9, should meet ANSI 2G Vibration test, Compliance to UL/ CE with Class I system rating shall be 50K hrs Lumen maintenance of 70%, system efficency 80lm / w. Over load & short circuit protection ensures reliable operation in spite of problem in output side. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB.. Top access steet light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED light fixture with 110 W system power consumption. LED efficiency 130 lm/ w at 1 w & fixture efficiency 80lm/ w with nominal CRI 75. Warranty of 5 Yrs. and as per directions of Engineer-in-charge. | Nos. | 18581.0 | 18581.0 | 2.0 | False | None | None | False | None | False | 37162.0 | 0 |
3472570 | 123950 | None | code38 | Fixing halogen/ metal halide/ SVL/ IL/ LED floodlight fitting over existing pole/ wall ceiling including clamps, bolts, nuts & wiring using suitable capacity wires. and as per directions of Engineer-in-charge. | Each | 162.0 | 162.0 | 2.0 | False | None | None | False | None | False | 324.0 | 0 |
3472571 | 123950 | None | code39 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides with of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws etc. a) 10" x 8" x 1.5" and as per directions of Engineer-in-charge. | Each | 102.0 | 102.0 | 8.0 | False | None | None | False | None | False | 816.0 | 0 |
3472572 | 123950 | None | code40 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden / panel using necessary nuts, bolts & washers 16 Amps and as per directions of Engineer-in-charge. | Each | 157.0 | 157.0 | 2.0 | False | None | None | False | None | False | 314.0 | 0 |
3472573 | 123950 | None | code41 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve , indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required. a) 5-32Amps SP Group 'A" and as per directions of Engineer-in-charge. | Each | 415.0 | 415.0 | 5.0 | False | None | None | False | None | False | 2075.0 | 0 |
3472574 | 123950 | None | code42 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting etc., complete. II. Double Door b) 8Way SP &N Group 'A' and as per directions of Engineer-in-charge. | Each | 1854.0 | 1854.0 | 1.0 | False | None | None | False | None | False | 1854.0 | 0 |
3472575 | 123950 | None | code43 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400 x 400 x 400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. and as per directions of Engineer-in-charge. | Each | 4256.0 | 4256.0 | 2.0 | False | None | None | False | None | False | 8512.0 | 0 |