createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1720269791282
version5
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd333000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose02-08-2024 16:00:00
tenderQueryClose25-07-2024 16:00:00
technicalBidOpen03-08-2024 16:30:00
publishedDate06-07-2024 19:05:55
publishedByPostDMA_EE1_CC_SMG
publishedByUserKPE11884 - MOHAMMED MUSTHAFA A M
bidValidityPeriod90
noOfCalls1
preBidMeetingDate25-07-2024 11:30:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonBHARATH KUMAR N
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9964286963
tenderSupplierListNone
tenderSchedule
createdTs1720269791317
version4
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/OW/WORK_INDENT18995
titleConstruction of Proposed 22TPD MRF Centre (Material Recovery Facility) of PEB Structure (PRIMARY & SECONDARY SHED) At Shivamogga
descriptionConstruction of Proposed 22TPD MRF Centre (Material Recovery Facility) of PEB Structure (PRIMARY & SECONDARY SHED) At Shivamogga
categoryWORKS
categoryTextWorks
ecv26250000.00
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2164
locationNameDMA City Corporation Shivamogga
provisionalAmount26250000.0
groupOverheadTotal4033662.97
fileNumberT-09/2024-25/01
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17202697910000NoneNoneOther WorksConstruction of Proposed 22TPD MRF Centre (Material Recovery Facility) of PEB Structure (PRIMARY & SECONDARY SHED) At Shivamogga22216337.03
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3471432123851NoneItem No. 1.14.1 Page No. 8 Vol.1 PWD SRKSRB 1-1.14.1: Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.Cum107.1107.1253.9FalseNoneNoneFalseNoneFalse27192.690
3471433123851NoneItem No. 2.1.2 Page No. 15 Vol.1 PWD SRKSRB 2-2.1.2: Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement & formwork shall be paid separately. Specification No. KBS 2.1,Cum5947.25947.2200.33FalseNoneNoneFalseNoneFalse1191402.5760
3471434123851NoneItem No. 2.3.2 Page No. 16 Vol.1 PWD SRKSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 FootingCum7322.47322.463.55FalseNoneNoneFalseNoneFalse465338.520
3471435123851NoneItem No. 2.3.2 Page No. 16 Vol.1 PWD SRKSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 Column BaseCum11340.011340.031.72FalseNoneNoneFalseNoneFalse359704.80
3471436123851NoneItem No. 2.3.2 Page No. 16 Vol.1 PWD SRKSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 Hall Grade slabCum7322.47322.4244.34FalseNoneNoneFalseNoneFalse1789155.2160
3471437123851NoneItem No. 2.2.3 Page No. 15 Vol.1 PWD SRKSRB 2-2.2.3.1 :Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum9820.89820.820.13FalseNoneNoneFalseNoneFalse197692.7040
3471438123851NoneItem No. 2.11 Page No. 18 Vol.1 PWD SRKSRB 2.11 Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Tonne93929.8593929.8521.7629FalseNoneNoneFalseNoneFalse2044185.9325650
3471439123851NoneItem No. 5.4 Page No. 9 Vol.2 PWD SRKSRB 5-5.4: Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) .Cum6708.456708.4591.28FalseNoneNoneFalseNoneFalse612347.3160
3471440123851NoneItem No. 1.8 Page No. 7 Vol.1 PWD SRKSRB 1-1.8: Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the workCum497.7497.7728.66FalseNoneNoneFalseNoneFalse362654.0820
3471441123851NoneItem No. 6.33 Page No. 17 Vol.2 PWD SRKSRB 6-6.33: Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1292.551292.55428.76FalseNoneNoneFalseNoneFalse554193.7380
3471442123851NoneItem No. 8.3.1, Page No. 41, Vol.2KSRB 8-8.3.1: Providing 15mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm309.75309.75892.27FalseNoneNoneFalseNoneFalse276380.63250
3471443123851NoneItem No. 11.2, Page No. 77, Vol.2Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. mAIN rOOFINGKgs118.65118.6578600.0FalseNoneNoneFalseNoneFalse9325890.00
3471444123851NoneItem No. 7.69.3, Page No. 38, Vol.2Providing and fixing Aluminium Turbo ventilator complete as per technical specifications Non Power Driven with 1.3mm thickness and 38 No.s of Vanes & turbine doom thickness 1mm and total weight not less than 6kg for Industrial use for area upto 100m2 for Industrial useNo5880.05880.010.0FalseNoneNoneFalseNoneFalse58800.00
3471445123851NoneItem No. 7.38, Page No. 26, Vol.2Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.Sqm596.4596.43159.55FalseNoneNoneFalseNoneFalse1884355.620
3471446123851NoneItem No. 8.51, Page No. 50, Vol.2KSRB 8-8.51 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm105.0105.0892.27FalseNoneNoneFalseNoneFalse93688.350
3471447123851NoneItem No. 8.54.1, Page No. 50, Vol.2KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.Sqm76.6576.65432.91FalseNoneNoneFalseNoneFalse33182.55150
3471448123851NoneItem No. 8.54.1, Page No. 50, Vol.2KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.Sqm76.6576.65395.87FalseNoneNoneFalseNoneFalse30343.43550
3471449123851NoneItem No. 11.6.1, Page No. 76, Vol.2KSRB 11-11.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm2764.652764.6557.38FalseNoneNoneFalseNoneFalse158635.6170
3471450123851NoneItem No. 11.8.4, Page No. 77, Vol.2KSRB 11-11.8.4:Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Each25920.325920.33.0FalseNoneNoneFalseNoneFalse77760.90
3471451123851NoneItem No. 11.35.1.1, Page No. 87, Vol.2KSRB 11-11.35.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications.Kg474.6474.6690.0FalseNoneNoneFalseNoneFalse327474.00
3471452123851None00102 00 105-RCC Pole 9.0M Long 145 kg WL Digging of Pits 1.8 mtr depth for errection of 9 to 10 mtr Long Steel RCC PSC supports as per approved Drawing - Ordinary Soil Erection of RCC poles 9 to 10 mtr long but in a pit of 1.8 mtr depth. - Ordinary SoilNos8598.458598.451.0FalseNoneNoneFalseNoneFalse8598.450
3471453123851None00202 00 103-RCC Pole-8.0M Long 115 kg WL Digging of Pits 1.5 mtr depth for errection of 7.5/8 mtr Long Steel/RCC/PSC/PCC supports as per approved Drawing - Ordinary Soil Erection of RCC poles of 7.5 to 8 mtr long in pit of 1.5 mtr depth - Ordinary SoilNos6881.76881.71.0FalseNoneNoneFalseNoneFalse6881.70
3471454123851None00311kV Horizontal CrossArm with single top support, clamp, Bolt & Nuts with washers for RCC Poles- MS Fixing of V-Shape /Horizontal cross arm including single top support Braces and Insulatorsfixing.-OrdinarySoilSet948.15948.152.0FalseNoneNoneFalseNoneFalse1896.30
3471455123851None004Double Pole Structure Complete including 5KG 8-SWGG.I .wire for Structure Grounding For 9Mtr RCC Poles145kg WL (with pole) Digging of Pits 1.8mtr depth for errection of 9 to 10mtr Long Steel /RCC /PSC support sas perapproved Drawing OrdinarySoil Erection of 2pole structure formed out of SMrails or I Beam of sizes 200x100175x90 mm, 225x100mm of using RCC poles 9mtr to 10mtr long inpits of 1.8mtr depth for line deviation with necessary foundation, inclusive of fixing of cross Arms Braces, Strain Insulators OrdinarySoilSet27636.027636.01.0FalseNoneNoneFalseNoneFalse27636.00
3471456123851None0050281683 Spiral Earth Electrode Providing spiral earth electrode type earthing along with pole (withoutcharcoal saltetc.,) OrdinarySoilNos348.6348.63.0FalseNoneNoneFalseNoneFalse1045.80
3471457123851None006Guy set with 2Nos. 15 strain insulator & Concreting materials as per Drwg No.BESCOM/GM/CP/7/Dt; 24.10.07 Digging of Pit for GUY SET - Ordinary Soil Fixing of GUY Sets with break insulators making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT) but using 2 strain insulators (No.15) for - Anticlimbing D - Ordinary SoilSet1958.251958.252.0FalseNoneNoneFalseNoneFalse3916.50
3471458123851None0072 Pin Cross Arm with pole clamp, bolts & nuts & washers for RCC Pole - MS Fixing of 2 Pin cross arm with insulator and Braces fixing - Ordinary SoilSet447.3447.32.0FalseNoneNoneFalseNoneFalse894.60
3471459123851None00802 83 320-Silcon rubber composite disk insulator/11kV 45 kN Polymeric insulatorNos195.3195.36.0FalseNoneNoneFalseNoneFalse1171.80
3471460123851None00902 83 007-11kV Pin Insulator (Both Shell and G.I. Pin) - PolymericNos215.25215.256.0FalseNoneNoneFalseNoneFalse1291.50
3471461123851None011HT Single Top Support Set with Bolts Nut and Washers Fixing of HT/LT single top support . - Ordinary SoilSet264.6264.63.0FalseNoneNoneFalseNoneFalse793.80
3471462123851None01102 81 010-10 SWG G.I.WireKg83.1283.1210.0FalseNoneNoneFalseNoneFalse831.20
3471463123851None01202 79 150-H Frame for GOS 400 Amps Erection of H Frame. - Ordinary SoilSet6713.76713.71.0FalseNoneNoneFalseNoneFalse6713.70
3471464123851None01303 04 212-11kV 200Amps Single Break GOS Fixing of GOS including wiring g (11kV SB 200A) - Ordinary SoilSet11081.711081.71.0FalseNoneNoneFalseNoneFalse11081.70
3471465123851None01408 21 900-Transparent Alkathine tube 19mm dia 2mm thick in coils of 30 mtrsCoil542.85542.852.0FalseNoneNoneFalseNoneFalse1085.70
3471466123851None01503 03 201-10KV 5kA LA Polymeric type with GROUND DISCONNECTOR Fixing of lightning arrestors including wiring. - Ordinary SoilSet5114.565114.561.0FalseNoneNoneFalseNoneFalse5114.560
3471467123851None01603 58 351-11kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3CT & 3PTs, With Transparent Cover TTB, Modem and 2 Nos of Meters for 3Ph 4 Wire Metering without Load Break Switch Erection of HT metering Cubicle on Platform. - Ordinary SoilNos257581.8257581.81.0FalseNoneNoneFalseNoneFalse257581.80
3471468123851None01705 06 492-Load Break Switches with pannel10.541Transmissionplant Transformershavingratingof100KVAandaboveNos76900.9576900.951.0FalseNoneNoneFalseNoneFalse76900.950
3471469123851None018Earthing Material Set Digging of pit. For providing GI Pipe type Earthing - Ordinary Soil Providing GI Pipe Earthing for lightning arresters Transformer Neutral and Transformer Metal parts (Excluding digging of pits) - Ordinary SoilSet2811.92811.94.0FalseNoneNoneFalseNoneFalse11247.60
3471470123851None01903 21 473-250 kVA, Aluminium Wdg, Star 2 (5 Star) Cable Entry Type Distribution Transformer - 3 Phase, 11kV/433V - Stacked Core with Oil.Nos569830.8569830.81.0FalseNoneNoneFalseNoneFalse569830.80
3471471123851None020Providing chain link fencing 50mm size of 8 guage properly stretched between rectangular poles andfixed with suitable bolts & nuts, the free ends shall be welded to the pole and block pipe at top and bottomas required including cost of all materials, laSqm1026.91026.930.0FalseNoneNoneFalseNoneFalse30807.00
3471472123851None021Construction of platform with size stone, cement concert for erection of 500 kVA Transformer/Heavy Equipment.Construction of platform (1.5x1.5x1.2) mtr in size stone, for erection of transformers/Heavy equipment including all materials, labour.Excavation of (1.5x1.5x1.2)10.612 UndergroundCables-cableductsystemStrings27721.0527721.051.0FalseNoneNoneFalseNoneFalse27721.050
3471473123851None02202 87 400-11kV, 3 Core, XLPE HTUG Cable (ROUND Armoured) 95 SqmmKm934149.3934149.30.11FalseNoneNoneFalseNoneFalse102756.4230
3471474123851None02302 87 214 Armoured L.T.UG Cable 1.1kV Class 185Sq.mm 3.5 coreKm725778.9725778.90.11FalseNoneNoneFalseNoneFalse79835.6790
3471475123851None02402 88 302 Heat Shrinkable outdoor type cable termination kit for XLPE cable 3X95 Sq.mm(11 KV) Making and Fixing pot head for HT Cable only Heat shrinkable type - 3x300 to 3x400 Sqmm Ordinary SoilSet7061.257061.252.0FalseNoneNoneFalseNoneFalse14122.50
3471476123851None02502 88 332-Heat Shrinkable indoor type cable termination kit for XLPE cable 3X95 Sq.mm(11 KV) Making and Fixing pot head for HT Cable only Heat shrinkable type - 3x300 to 3x400 Sqmm - Ordinary SoilSet6722.16722.16.0FalseNoneNoneFalseNoneFalse40332.60
3471477123851None02607 68 052-GI Pipe 100 mm dia Laying the GI Pipe 80mm to 150 mm dia at Drainage Water Supply Crossing including fixing collars elbows, bends, Tees and other fitting with Cuts and Threads wherever necessary complete. - Ordinary Soilm1394.41394.420.0FalseNoneNoneFalseNoneFalse27888.00
3471478123851None5.42.2Fabricating supplying and mounting MS box made out SWG.suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.18 SWGSq CM0.40.490000.0FalseNoneNoneFalseNoneFalse36000.00
3471479123851None5.52.8Supply and fixing of 3-pole Capacitor switching contactor with NO/NC contacts and inbuilt damping resistor to protect the contactor and capacitor from highest inrush current , fixed on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC 690V Rating operational voltage,.50HZ frequency and as per IS 60947-4-1. 80 KVAREach23377.223377.24.0FalseNoneNoneFalseNoneFalse93508.80
3471480123851None5.39Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect/ disconnect banks, with automatic recognition or with standard.programsEach22722.022722.01.0FalseNoneNoneFalseNoneFalse22722.00
3471481123851None5.37Supplying, fixing andwiring heavy duty lowvoltage capacitors conforming toIS2834. 3phase, 400/440Vgrade, for power factor improvement of rotating machineries like induction motor.Kvar105.0105.0480.0FalseNoneNoneFalseNoneFalse50400.00
3471482123851None51.04Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified 281685 No 1910 2172Nos2280.62280.63.0FalseNoneNoneFalseNoneFalse6841.80
3471483123851None51.05Bentonite clay slurry for earthing in 50 Kg Bag Bag386.4386.43.0FalseNoneNoneFalseNoneFalse1159.20
3471484123851None5.53Supply and fixing of Auxiliary contactor relay with 2 NO and 2 NC contact and operating coil voltage of 220V to 260V. fixed on existing wood/panel board using necessary bolts, nuts,.washers and wiring etc.,Each1396.51396.58.0FalseNoneNoneFalseNoneFalse11172.00
3471485123851None5.40.3Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS.specification with necessary bolts, nuts and washers etc., complete, 400 A 4 x 50 x 10 mm Aluminium Stripsm4667.254667.2510.0FalseNoneNoneFalseNoneFalse46672.50
3471486123851None035Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS.specification with necessary bolts, nuts and washers etc., complete, 100 A 4 x 30 x 6 mm Aluminium Stripsm2588.252588.2520.0FalseNoneNoneFalseNoneFalse51765.00
3471487123851None5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 100 A 25 kAEach8911.358911.358.0FalseNoneNoneFalseNoneFalse71290.80
3471488123851None5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on.DIN rail/ flush mounting on panel board.Each9717.759717.751.0FalseNoneNoneFalseNoneFalse9717.750
3471489123851None5.27Supplying, fixing and wiring rotary selector switch suitable for.AmmeterEach210.0210.03.0FalseNoneNoneFalseNoneFalse630.00
3471490123851None5.28Supplying, fixing and wiring rotary selector switch suitable for.VoltmeterEach168.0168.03.0FalseNoneNoneFalseNoneFalse504.00
3471491123851None5.34Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current.Transformer Class 0.5 accuracy with Tape Wound.Each590.1590.13.0FalseNoneNoneFalseNoneFalse1770.30
3471492123851None5.38Supplying and fixing of LED type panel board indicating lamp.with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each540.75540.753.0FalseNoneNoneFalseNoneFalse1622.250
3471493123851None5.15.16Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR Pole 400 A 36 kAEach29626.829626.81.0FalseNoneNoneFalseNoneFalse29626.80
3471494123851None5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC.60898.50-63 A TPNEach3242.43242.45.0FalseNoneNoneFalseNoneFalse16212.00
3471495123851None5.53Supply and fixing of Auxiliary contactor relay with 2 NO and 2 NC contact and operating coil voltage of 220V to 260V. fixed on existing wood/panel board using necessary bolts, nuts,.washers and wiring etc.,Each1396.51396.53.0FalseNoneNoneFalseNoneFalse4189.50
3471496123851None5.18.4Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC.60898. 6-32 A DPEach775.95775.9510.0FalseNoneNoneFalseNoneFalse7759.50
3471497123851None5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracyEach9780.759780.751.0FalseNoneNoneFalseNoneFalse9780.750
3471498123851None5.41.2Supplying and fixing angle iron frame work fabricated out of M.S.angle iron. and M.S. Flat.with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 50 x 50 x 6 mmm414.75414.7525.0FalseNoneNoneFalseNoneFalse10368.750
3471499123851None32.081.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 25 Sqmm, 4 Core, (13 GI Strips - 4 x 0.8 mm)Km188836.2188836.20.2FalseNoneNoneFalseNoneFalse37767.240
3471500123851None32.031.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975.10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm)Km123904.2123904.20.2FalseNoneNoneFalseNoneFalse24780.840
3471501123851None21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. 2.5 to 25 SqmmKm21930.321930.30.4FalseNoneNoneFalseNoneFalse8772.120
3471502123851None66.04HDPE/PLB Pipe 50/42 mmKm89264.789264.70.1FalseNoneNoneFalseNoneFalse8926.470
3471503123851None1.92Supplying PVC flexible conduit pipe . mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely.25 mm .m23.123.1150.0FalseNoneNoneFalseNoneFalse3465.00
3471504123851None1.1.2Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.25 mm dia 2 mm thick .m85.0585.05450.0FalseNoneNoneFalseNoneFalse38272.50
3471505123851None1.1.1Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.19/20 mm dia 2 mm thick . KPWD Comman SR 2023-24 Item No: 1.1.1m72.4572.45250.0FalseNoneNoneFalseNoneFalse18112.50
3471506123851None1.5.1Supplying and fixing PVC metal conduit Deep junction box19 20 mm deep Junction box .Each51.4551.4530.0FalseNoneNoneFalseNoneFalse1543.50
3471507123851None1.5.2Supplying and fixing PVC/metal conduit Deep junction box.25 mm deep Junction box . KPWD Comman SR 2023-24 Item No: 1.5.2Each58.858.830.0FalseNoneNoneFalseNoneFalse1764.00
3471508123851None1.5.3Supplying and fixing PVC/metal conduit Deep junction box32 mm deep Junction box . KPWD Comman SR 2023-24 Item No: 1.5.3Each64.0564.0530.0FalseNoneNoneFalseNoneFalse1921.50
3471509123851None2.5.23Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for.working voltage upto 1100 Volts as per IS-694:1990. 4C x 6 mm2 . KPWD Comman SR 2023-24 Item No: 2.5.23m344.4344.440.0FalseNoneNoneFalseNoneFalse13776.00
3471510123851None2.5.16Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for.working voltage upto 1100 Volts as per IS-694:1990. 4C x 4 mm2 . KPWD Comman SR 2023-24 Item No: 2.5.16m236.25236.2540.0FalseNoneNoneFalseNoneFalse9450.00
3471511123851None1.7.2Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto.wall surface complete. upto 50 mm conduit CC floor . KPWD Comman SR 2023-24 Item No: 1.7.2m72.4572.45150.0FalseNoneNoneFalseNoneFalse10867.50
3471512123851None1.7.1Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto.wall surface complete. upto 50 mm conduit in brick wall . KPWD Comman SR 2023-24 Item No: 1.7.1m30.4530.45150.0FalseNoneNoneFalseNoneFalse4567.50
3471513123851None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010. 1.5 mm2m27.327.31000.0FalseNoneNoneFalseNoneFalse27300.00
3471514123851None2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010.2.5 mm2m44.144.1750.0FalseNoneNoneFalseNoneFalse33075.00
3471515123851None2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010.4 mm2 .m66.1566.15300.0FalseNoneNoneFalseNoneFalse19845.00
3471516123851None2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010 6 mm2 .m96.696.6300.0FalseNoneNoneFalseNoneFalse28980.00
3471517123851None3.3.6Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs,.Machine/NF screws etc., complete.10-12 Way . KPWD Comman SR 2023-24 Item No: 3.3.6Each274.05274.0520.0FalseNoneNoneFalseNoneFalse5481.00
3471518123851None3.3.7Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs,.Machine/NF screws etc., complete. 16 Way . KPWD Comman SR 2023-24 Item No: 3.3.7Each308.7308.715.0FalseNoneNoneFalseNoneFalse4630.50
3471519123851None3.3.8Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs,.Machine/NF screws etc., complete.18 Way . KPWD Comman SR 2023-24 Item No: 3.3.8Each355.95355.9510.0FalseNoneNoneFalseNoneFalse3559.50
3471520123851None3.3.5Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs,.Machine/NF screws etc., complete.8 Way . KPWD Comman SR 2023-24 Item No: 3.3.5Each229.95229.9510.0FalseNoneNoneFalseNoneFalse2299.50
3471521123851None3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing.metal/PVC box.8 Module . KPWD Comman SR 2023-24 Item No: 3.5.5Each298.2298.210.0FalseNoneNoneFalseNoneFalse2982.00
3471522123851None3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing.metal/PVC box.10-12 Module . KPWD Comman SR 2023-24 Item No: 3.5.6Each361.2361.220.0FalseNoneNoneFalseNoneFalse7224.00
3471523123851None3.5.7Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing.metal/PVC box.16 Module . KPWD Comman SR 2023-24 Item No: 3.5.7Each416.85416.8515.0FalseNoneNoneFalseNoneFalse6252.750
3471524123851None3.5.8Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing.metal/PVC box.18 Module . KPWD Comman SR 2023-24 Item No: 3.5.8Each479.85479.8510.0FalseNoneNoneFalseNoneFalse4798.50
3471525123851None3.6.1Supplying and fixing of modular switch & connected accessories on.existing modular switch plate as per IS 3854 and IS 1293.6A One Way Switch . KPWD Comman SR 2023-24 Item No: 3.6.1Each107.1107.140.0FalseNoneNoneFalseNoneFalse4284.00
3471526123851None3.6.7Supplying and fixing of modular switch & connected accessories on.existing modular switch plate as per IS 3854 and IS 1293.16A One Way Switch . KPWD Comman SR 2023-24 Item No: 3.6.7Each189.0189.010.0FalseNoneNoneFalseNoneFalse1890.00
3471527123851None3.6.10Supplying and fixing of modular switch & connected accessories on.existing modular switch plate as per IS 3854 and IS 1293.6/16A Universal Socket . KPWD Comman SR 2023-24 Item No: 40243Each247.8247.820.0FalseNoneNoneFalseNoneFalse4956.00
3471528123851None3.13.4Supplying and fixing of metal clad industrial plugs and sockets. 3pole+earth 440V PLUG.32A . KPWD Comman SR 2023-24 Item No: 3.13.4Each640.35640.356.0FalseNoneNoneFalseNoneFalse3842.10
3471529123851None3.13.8Supplying and fixing of metal clad industrial plugs and sockets. 32A . KPWD Comman SR 2023-24 Item No: 3.13.8Each869.21869.216.0FalseNoneNoneFalseNoneFalse5215.260
3471530123851None3.14.12Supplying And fixing/replacing of 6/16/32A electrical.accessories on existing switch board.16A Three Way 5 Pin Socket .No120.75120.758.0FalseNoneNoneFalseNoneFalse966.00
3471531123851None6.2.2Supplying of 1440rpm heavy duty exhaust fan with bracket blades.suitable to operate on 230V 50Hz, AC Supply complete. 15" Sweep (450 mm)Each4668.34668.35.0FalseNoneNoneFalseNoneFalse23341.50
3471532123851None11.8.4Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr Lumen Maintenance of 70 maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection Min 5KV along with Over voltage Overload, short circuit miss wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50 60Hz application. Compliance to IS 10322 IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency 1301m w, nominal CRI 75. Luminaire manufacturer should have in house facility accredited by NABL CPRI any Government certified agency & Design Development facility certified by ISO 9001 2008. Housing with supplier word mark name shall be Engraved Embossing on the die cast housing Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer Cree Nichia Lumileds Osram make LED Source. LED Streetlight 90wEach9303.09303.04.0FalseNoneNoneFalseNoneFalse37212.00
3471533123851None11.9.2Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr Lumen Maintenance of 70, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System.Power consumption. LED Efficiency 1301mw, nominal CRI 75. Luminaire manufacturer should have in house facility accredited by NABL CPRI & any Government certified agency & Design Development facility certified by ISO 9001 2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree Nichia Lumileds Osram make LED Source.LED Floodlight 100WEach9960.39960.36.0FalseNoneNoneFalseNoneFalse59761.80
3471534123851None11.8.3Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency1301mw, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer Cre Nichia Lumileds Osram make LED Source.LED Streetlight 70WEach6291.66291.68.0FalseNoneNoneFalseNoneFalse50332.80
3471535123851None13.2.1Supplying and Fixing.mm dia clampsss A GI pipe bracket upto.2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV SV MH FTL street light fitting of all capacities on rail RCC wall tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires.Using 25mm dia G.I.PipeEach1263.151263.153.0FalseNoneNoneFalseNoneFalse3789.450
3471536123851None13.5Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over.existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.Each170.1170.110.0FalseNoneNoneFalseNoneFalse1701.00
3471537123851None11.3.3Supplying of feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours 70% lumen maintenance with CRI 80. Power Input: 220-240V 50 60Hz Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' 36 40 WEach1332.451332.4510.0FalseNoneNoneFalseNoneFalse13324.50
3471538123851None13.7.2Fixing all types and all capacities of fluorescent /false ceiling spot light CFL LED fittings indoor on the wall/ ceiling / rafters girders using 23 0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps.Using necessary length of G.I. chainEach276.15276.1510.0FalseNoneNoneFalseNoneFalse2761.50
3471539123851None5.22Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter.on existing panel/wood board.Each474.6474.61.0FalseNoneNoneFalseNoneFalse474.60
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17202697980000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17202697980000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17202697980000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17202697980000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17202697980000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17202698380000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17202698490000NoneNoneELIGIBILITYBidder has to quote rates excluding GST, GST shall be paid separately for the applicableNone
17202698560000NoneNoneELIGIBILITYTurnover certificate from CA with valid UDIN No. to be furnished along with necessary documentsNone
17202698610000NoneNoneELIGIBILITYOnly relevant documents should be submitted in e-procurementNone
17202698780000NoneNoneELIGIBILITYAll terms and conditions as per standard tender documentNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneliquid assets and or availability of credit facilities of no less than Rs.66.65 Lakhs (Credit lines/ letters of credit/ certificates from banks for meeting the fund requirement etc.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneExecuted in any one year ( for a continuous period of 12 months) , the minimum quantities of work ( usually 80 % of annual requirement) for works costing more than Rs. 100 Lakhs.(Specify the principal items of works to be executed under this contract) quantities mentioned in bid documetPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneSatisfactory completed, (at least 90%of contract value)as prime contractor, at least one Building work of value not less than Rs. 111.08 Lakhs. (Usually not less than 50% of estimated value of contract).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneupload class 2 and above pwd civil contractor license copyCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- upload class 2 and above pwd civil contractor license copy
NoneNoneNoneNonePAN/GST CertificateFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneTo qualify for award of this contract, each tenderer in its name should have in the last five years i.e., 2019-20 to 2023-24 Achieved in at least two financial years a minimum annual financial turnover of Rs.444.32 lakhs.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNonenot mandatoryOthersnot mandatory
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- not mandatory
NoneNoneNoneNonenot mandatoryOthersnot mandatory
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- not mandatory
NoneNoneNoneNonenot mandatoryOthersnot mandatory
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- not mandatory
NoneNoneNoneNonenot mandatoryOthersnot mandatory
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- not mandatory
NoneNoneNoneNonenot mandatoryOthersnot mandatory
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- not mandatory
NoneNoneNoneNonenot mandatoryOthersnot mandatory
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- not mandatory
NoneNoneNoneNonenot mandatoryOthersnot mandatory
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- not mandatory
NoneNoneNoneNonesubmit list of ongoing commitments of work in all departments CompulsoryOtherssubmit list of ongoing commitments of work in all departments Compulsory
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- submit list of ongoing commitments of work in all departments Compulsory
NoneNoneNoneNonecontractor has to upload the valid EPF registration certificateOtherscontractor has to upload the valid EPF registration certificate
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneValid EPF Certificate
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
All other documents as per tender documentTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1720272487000
version0
createdDateNone
modifiedDateNone
blockNumbershivamogga city corporation office
streetNone
cityShivamogga
stateKarnataka
pin577201
tenderRecallDTONone