| 1719914089000 | 1 | None | None | Buildings | Construction of Community toilet at near Smashaana Hosapete Road Raajeev Gandhi Nagararoad in Kudligi Town Limit | 1899193.93 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3435081 | 121745 | None | code001 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m[Volume-I PNO-8,INO-1.14.1Of 2023-24 PWD SR] | Cum | 107.1 | 107.1 | 40.73 | False | None | None | False | None | False | 4362.183 | 0 | | 3435082 | 121745 | None | code002 | Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work[PNO 17,INO-3.1Of 2023-2024 PWD SR-V3] | Cum | 89.25 | 89.25 | 40.73 | False | None | None | False | None | False | 3635.1525 | 0 | | 3435083 | 121745 | None | code003 | Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications[PN-11,INO-1.23-V-1-Common SR] | Cum | 2816.1 | 2816.1 | 8.162 | False | None | None | False | None | False | 22985.0082 | 0 | | 3435084 | 121745 | None | code004 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separatelyMix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates[Volume-I,PNO-15,INO-2.1.2 Of 2023-2024 PWD SR] | Cum | 5947.2 | 5947.2 | 15.22 | False | None | None | False | None | False | 90516.384 | 0 | | 3435085 | 121745 | None | code005 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel \ reinforcement & formwork to be paid separately.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates[Volume-I,PNO-16, INO-2.3.2 Of PWD SR For 2023-24] | Cum | 6804.0 | 6804.0 | 6.18 | False | None | None | False | None | False | 42048.72 | 0 | | 3435086 | 121745 | None | code006 | Providing Centering to Concrete works for footing | Cum | 544.32 | 544.32 | 3.18 | False | None | None | False | None | False | 1730.9376 | 0 | | 3435087 | 121745 | None | code007 | Providing Centering to Concrete works for plinth and roof beams | Cum | 4082.4 | 4082.4 | 3.0 | False | None | None | False | None | False | 12247.2 | 0 | | 3435088 | 121745 | None | code008 | Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Volume-II,PNO-9, INO-5.3 Of PWD SR For 2023-24] | Cum | 6515.25 | 6515.25 | 18.289 | False | None | None | False | None | False | 119157.40725 | 0 | | 3435089 | 121745 | None | code009 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.[Volume-I,PNO-7, INO-1.11 Of PWD SR For 2023-24] | Cum | 454.65 | 454.65 | 57.7 | False | None | None | False | None | False | 26233.305 | 0 | | 3435090 | 121745 | None | code010 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel \ reinforcement & formwork to be paid separatelyM25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates[Volume-I,PNO-16, INO-2.3.2 Of PWD SR For 2023-24] | Cum | 6804.0 | 6804.0 | 2.29 | False | None | None | False | None | False | 15581.16 | 0 | | 3435091 | 121745 | None | code011 | Providing Centering to Concrete works for columns and roof slab | Cum | 4082.4 | 4082.4 | 2.29 | False | None | None | False | None | False | 9348.696 | 0 | | 3435092 | 121745 | None | code012 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.[Volume-II,PNO-17, INO-6.32 Of PWD SR For 2023-24] | Sqm | 1375.5 | 1375.5 | 104.034 | False | None | None | False | None | False | 143098.767 | 0 | | 3435093 | 121745 | None | code013 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.[Volume-II,PNO-17, INO-6.34 Of PWD SR For 2023-24] | Sqm | 1159.2 | 1159.2 | 44.82 | False | None | None | False | None | False | 51955.344 | 0 | | 3435094 | 121745 | None | code014 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)[Volume-I,PNO-15, INO-2.2.5 Of PWD SR For 2023-24] | Cum | 6823.95 | 6823.95 | 1.41 | False | None | None | False | None | False | 9621.7695 | 0 | | 3435095 | 121745 | None | code015 | Providing Centering to Concrete works for lintel beams | Cum | 4094.37 | 4094.37 | 1.41 | False | None | None | False | None | False | 5773.0617 | 0 | | 3435096 | 121745 | None | code016 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings (Volume 1 P No. 18 I No 2.11 a PWD SR 2023-24 Common Shedule of Rates | Tonne | 93929.85 | 93929.85 | 1.26 | False | None | None | False | None | False | 118351.611 | 0 | | 3435097 | 121745 | None | code017 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding[Volume-II,PNO-86, INO-11.34B Of PWD SR For 2023-24] | Kgs | 192.15 | 192.15 | 177.66 | False | None | None | False | None | False | 34137.369 | 0 | | 3435098 | 121745 | None | code018 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge[Volume-II,PNO-77, INO-11.5.2 Of PWD SR For 2023-24] | Sqm | 4454.1 | 4454.1 | 4.2 | False | None | None | False | None | False | 18707.22 | 0 | | 3435099 | 121745 | None | code019 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer,
including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. [Volume-II,PNO-82, INO-11.16.1 Of PWD SR For 2023-24] | Kgs | 142.8 | 142.8 | 930.2 | False | None | None | False | None | False | 132832.56 | 0 | | 3435100 | 121745 | None | code020 | Providing & fixing corrugated G.S. sheet roofing including vertical /curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge- 0.63 mm thick with zinc coating not less than 275 g/ m² [Volume-II,PNO-21, INO-7.11 Of PWD SR For 2023-24] | Sqm | 922.95 | 922.95 | 89.93 | False | None | None | False | None | False | 83000.8935 | 0 | | 3435101 | 121745 | None | code021 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge[Volume-II,PNO-42, INO-8.5.2.Of PWD SR For 2023-24] | Sqm | 366.45 | 366.45 | 230.59 | False | None | None | False | None | False | 84499.7055 | 0 | | 3435102 | 121745 | None | code022 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge[Volume-II,PNO-42, INO-8.5.2.Of PWD SR For 2023-24] | Sqm | 366.45 | 366.45 | 92.17 | False | None | None | False | None | False | 33775.6965 | 0 | | 3435103 | 121745 | None | code023 | Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. [Volume-II,PNO-44, INO-8.21 Of PWD SR For 2023-24] | Sqm | 27.3 | 27.3 | 322.76 | False | None | None | False | None | False | 8811.348 | 0 | | 3435104 | 121745 | None | code024 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including
preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. [Volume-II,PNO-47, INO-8.33.3 Of PWD SR For 2023-24] | Sqm | 145.95 | 145.95 | 19.98 | False | None | None | False | None | False | 2916.081 | 0 | | 3435105 | 121745 | None | code025 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved
type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary
hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For::PVC pipes 110mm dia.6 kG/cm2 class 3 [.PNO-113, INO-10.1.7-VOL-5, Of BWSSB SR For 2023-24] | Mtr | 431.55 | 431.55 | 60.0 | False | None | None | False | None | False | 25893.0 | 0 | | 3435106 | 121745 | None | code026 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications [Volumme-II,PNO-65, INO-9.39.Of PWD SR For 2023-24] | Sqm | 1521.45 | 1521.45 | 14.5 | False | None | None | False | None | False | 22061.025 | 0 | | 3435107 | 121745 | None | code027 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete[Volume-II,PNO-60, INO-9.11 Of PWD SR For 2023-24] | Sqm | 933.45 | 933.45 | 63.88 | False | None | None | False | None | False | 59628.786 | 0 | | 3435108 | 121745 | None | code028 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fix- tures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with
integral type foot rests (Volume 2 P No.131 I No 14.1.1 PWD SR 2023-24 | Each | 5128.2 | 5128.2 | 15.0 | False | None | None | False | None | False | 76923.0 | 0 | | 3435109 | 121745 | None | code029 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps[Volume 2 P No.132 I No 14.7.1 PWD SR 2023-24 | Each | 3236.1 | 3236.1 | 4.0 | False | None | None | False | None | False | 12944.4 | 0 | | 3435110 | 121745 | None | code030 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge[Volume-II,PNO-104, INO-12.54 Of PWD SR For 2023-24] | Mtr | 333.9 | 333.9 | 79.2 | False | None | None | False | None | False | 26444.88 | 0 | | 3435111 | 121745 | None | code031 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges- do- with one side prelam [Vol-II,PNO-104, INO-12.55.2 Of PWD SR For 2023-24] | Sqm | 2142.0 | 2142.0 | 25.2 | False | None | None | False | None | False | 53978.4 | 0 | | 3435112 | 121745 | None | code032 | Geophysical investigation at site for sinking borewells for supplyi drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner orSchlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test etc. Complete. | Each | 5552.4 | 5552.4 | 1.0 | False | None | None | False | None | False | 5552.4 | 0 | | 3435113 | 121745 | None | code033 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) For borewell depths 0 to 50 mtrs | Mtr | 388.5 | 388.5 | 50.0 | False | None | None | False | None | False | 19425.0 | 0 | | 3435114 | 121745 | None | code034 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) For borewell depths 50 to 100 mtrs | Mtr | 487.2 | 487.2 | 50.0 | False | None | None | False | None | False | 24360.0 | 0 | | 3435115 | 121745 | None | code035 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) For borewell depths 100 to 150 mtrs | Mtr | 517.65 | 517.65 | 10.0 | False | None | None | False | None | False | 5176.5 | 0 | | 3435116 | 121745 | None | code036 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete., 200mm Dia(weight of pipe -6.233 kg) | Mtr | 1300.95 | 1300.95 | 12.0 | False | None | None | False | None | False | 15611.4 | 0 | | 3435117 | 121745 | None | code037 | Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For3.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00” | Each | 29518.65 | 29518.65 | 1.0 | False | None | None | False | None | False | 29518.65 | 0 | | 3435118 | 121745 | None | code038 | Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments.,1x 3 C X 4.0 Sq.mm | Mtr | 141.75 | 141.75 | 80.0 | False | None | None | False | None | False | 11340.0 | 0 | | 3435119 | 121745 | None | code039 | Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 50 mm | Each | 1312.5 | 1312.5 | 1.0 | False | None | None | False | None | False | 1312.5 | 0 | | 3435120 | 121745 | None | code040 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor typ e NOTE: 1) DOLDirect Online Starter 2) S-D- Star Delta Starter 3 to 6 HP pumps | Each | 10027.5 | 10027.5 | 1.0 | False | None | None | False | None | False | 10027.5 | 0 | | 3435121 | 121745 | None | code041 | Supply and delivery of galvanized mild steel tubes of 6mtr standard length heavy duty (C Class) as per IS 1239 (Part-I) 1990 with latest amendments with ISI Mark (one end fitted with Heavy Duty collar and other end fitted with protective cover) 50 mm | Each | 3202.5 | 3202.5 | 12.0 | False | None | None | False | None | False | 38430.0 | 0 | | 3435122 | 121745 | None | code042 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. | Job | 6825.0 | 6825.0 | 1.0 | False | None | None | False | None | False | 6825.0 | 0 | | 3435123 | 121745 | None | code043 | Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer incharge of work. | Job | 1522.5 | 1522.5 | 1.0 | False | None | None | False | None | False | 1522.5 | 0 | | 3435124 | 121745 | None | code044 | Labour charges for providing connection using insulated sheathed steel wire cable as per IS 1554/ 1988 with latest amendments from KPTCL pole to meter board unit, with all necessary materials ,tools and equipments,as per specificationswith testing of as per instructions of engineer incharge of work. 3 x 10 sqmm (suitable for over head mains) | Mtr | 173.25 | 173.25 | 30.0 | False | None | None | False | None | False | 5197.5 | 0 | | 3435125 | 121745 | None | code045 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.In all kinds of soils. Depth upto 1.50m | Cum | 508.2 | 508.2 | 5.06 | False | None | None | False | None | False | 2571.492 | 0 | | 3435126 | 121745 | None | code046 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not lessthan 15 cms with gravel or selected earth available from the excavation etc. complete.90mm(weight of pipe -1.313 kg)6 Kg/m2 | Mtr | 270.9 | 270.9 | 15.0 | False | None | None | False | None | False | 4063.5 | 0 | | 3435127 | 121745 | None | code047 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications | Cum | 168.0 | 168.0 | 4.05 | False | None | None | False | None | False | 680.4 | 0 | | 3435128 | 121745 | None | code048 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc | Mtr | 500.85 | 500.85 | 100.0 | False | None | None | False | None | False | 50085.0 | 0 | | 3435129 | 121745 | None | code049 | Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes having thermal stability for hot cold water supply including all CPVC plain brass threaded fittings This includes jointing of pipes fittings with one step CPVC solvent cement trenching refilling testing of joints complete as per direction of Engineer in Charge for External work | Mtr | 310.8 | 310.8 | 40.0 | False | None | None | False | None | False | 12432.0 | 0 | | 3435130 | 121745 | None | code050 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. | Ltr | 9.45 | 9.45 | 1500.0 | False | None | None | False | None | False | 14175.0 | 0 | | 3435131 | 121745 | None | code051 | Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25 mm dia 2 mm thick | Mtr | 85.05 | 85.05 | 160.0 | False | None | None | False | None | False | 13608.0 | 0 | | 3435132 | 121745 | None | code052 | Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. - 25mm dia 2mm thick. | Mtr | 82.95 | 82.95 | 50.0 | False | None | None | False | None | False | 4147.5 | 0 | | 3435133 | 121745 | None | code053 | Point wiring using Copper wire with switch.- Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) &1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch | Point | 299.25 | 299.25 | 30.0 | False | None | None | False | None | False | 8977.5 | 0 | | 3435134 | 121745 | None | code054 | Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plasticsheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854-6A 3/5 Way | Each | 154.35 | 154.35 | 30.0 | False | None | None | False | None | False | 4630.5 | 0 | | 3435135 | 121745 | None | code055 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32A DP Switch | Each | 342.3 | 342.3 | 20.0 | False | None | None | False | None | False | 6846.0 | 0 | | 3435136 | 121745 | None | code056 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010 - 1.5 mm2 | Mtr | 27.3 | 27.3 | 200.0 | False | None | None | False | None | False | 5460.0 | 0 | | 3435137 | 121745 | None | code057 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board - 6A Bakelite Ceiling Rose | Each | 81.9 | 81.9 | 30.0 | False | None | None | False | None | False | 2457.0 | 0 | | 3435138 | 121745 | None | code058 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.- 6-32 A SP | Each | 435.75 | 435.75 | 4.0 | False | None | None | False | None | False | 1743.0 | 0 | | 3435139 | 121745 | None | code059 | Supplying and fixing regular MCB distribution boards on wall/ wall board/ flush mounting using required clamps , bolts, nuts , etc with provision for fixing suitable type capacity MCB s single phase /3 phase / single door with power coated painting. made out of 14 SWG MS enclosure I -single door 4 Ways SP N | Each | 1303.05 | 1303.05 | 4.0 | False | None | None | False | None | False | 5212.2 | 0 | | 3435140 | 121745 | None | code060 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 20A single phase Class-1 Accuracy with Temper Proof Energy Meter- | Each | 1449.0 | 1449.0 | 2.0 | False | None | None | False | None | False | 2898.0 | 0 | | 3435141 | 121745 | None | code061 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In ordinary/soft rock without blasting Depth exceeding 1.5m, but not exceeding 3 m (Page 6 Item No. 1.5.2 PWD CSR Vol. 1) | Cum | 467.25 | 467.25 | 18.0 | False | None | None | False | None | False | 8410.5 | 0 | | 3435142 | 121745 | None | code062 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 40 mm nominal size graded crushed coarse aggregates. (Page 15 Item No. 2.1.5 PWD CSR Vol. 1) | Cum | 6463.8 | 6463.8 | 1.35 | False | None | None | False | None | False | 8726.13 | 0 | | 3435143 | 121745 | None | code063 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Page 16 Item No. 2.4.2 PWD CSR Vol. 1) | Cum | 7303.07 | 7303.07 | 9.63 | False | None | None | False | None | False | 70328.5641 | 0 | | 3435144 | 121745 | None | code064 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Page 16 Item No. 2.4.2 PWD CSR Vol. 1) | Cum | 9958.73 | 9958.73 | 1.35 | False | None | None | False | None | False | 13444.2855 | 0 | | 3435145 | 121745 | None | code065 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge[Volume-II,PNO-42, INO-8.5.2.Of PWD SR For 2023-24] | Sqm | 366.45 | 366.45 | 45.0 | False | None | None | False | None | False | 16490.25 | 0 | | 3435146 | 121745 | None | code066 | Steel Fabrication- Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (Page 18 Item No. 2.11 h PWD CSR Vol. 1)- Assuming 80 Kgs Per Cum of Concrete | Tonne | 82961.55 | 82961.55 | 0.99 | False | None | None | False | None | False | 82131.9345 | 0 | | 3435147 | 121745 | None | code067 | Supply and fixing of SFRC machinhole cover (Medium Duty) made as per IS to suit existing damaged machinhole cover after removing the debries from inside and outside the existing machinhole etc. with all lead and lifts. Heavy duty (Page 208 SL No. 16.61.2 BWSSB CSR Vol. 5) | Each | 1294.65 | 1294.65 | 1.0 | False | None | None | False | None | False | 1294.65 | 0 | | 3435148 | 121745 | None | code068 | Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest ammendements etc. complete. 1.00 HP/0.75KW 10 STG (Page 149 SL No. 13.6.2 BWSSB CSR Vol. 5) | Each | 14605.5 | 14605.5 | 1.0 | False | None | None | False | None | False | 14605.5 | 0 | | 3435149 | 121745 | None | code069 | supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete. Upto 3 HP pumps (Page 154 SL No. 13.23.1 BWSSB CSR Vol. 5) | Each | 6825.0 | 6825.0 | 1.0 | False | None | None | False | None | False | 6825.0 | 0 | | 3435150 | 121745 | None | code070 | Providing and fixing board displaying information, such as 'Name of work, Tender cost, Name of Contractor, Work completion and liability period etc', having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge MoRTH specification 804 (P. no.78 : item no.8.54, V3 of SR 2023-24) | Each | 9450.0 | 9450.0 | 1.0 | False | None | None | False | None | False | 9450.0 | 0 |
|