createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1720265760495
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee1000.00
emd80000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose15-07-2024 16:00:00
tenderQueryClose12-07-2024 16:00:00
technicalBidOpen16-07-2024 16:30:00
publishedDate06-07-2024 17:36:06
publishedByPostTP_CO_BLGL
publishedByUserKPE16459 - NAMADEV LAMANI
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonM. B. Hosur
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9739640138
tenderSupplierListNone
tenderSchedule
createdTs1720265760581
version4
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/OW/WORK_INDENT20874
titleConstruction of 3 TPD MRF Centre (Material Recovery Facility) of PEB Structure (PRIMARY & Secondary Shed) at SWM Site Belagali.
descriptionConstruction of 3 TPD MRF Centre Material Recovery Facility of PEB Structure PRIMARY & Secondary Shed at SWM Site Belagali.
categoryWORKS
categoryTextWorks
ecv4000000.00
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2226
locationNameDMA Town Panchayat Belagali
provisionalAmount4000000.0
groupOverheadTotal617615.57
fileNumberTPB/SBM02/MRF/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17202657610000NoneNoneOther WorksConstruction of 3 TPD MRF Centre (Material Recovery Facility) of PEB Structure (PRIMARY & Secondary Shed) at SWM Site Belagali.3382384.43
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3471120123824Nonecode01KSRB 1-1.14.1: Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. (Item No. 1.14.1 Page No. 8 Vol.1 PWD SR)Cum105.06105.0636.64FalseNoneNoneFalseNoneFalse3849.39840
3471121123824Nonecode02KSRB 2-2.1.2: Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement & formwork shall be paid separately. Specification No. KBS 2.1, (Item No. 2.1.2 Page No. 15 Vol.1 PWD SR)Cum5833.925833.9239.71FalseNoneNoneFalseNoneFalse231664.96320
3471122123824Nonecode03KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115)Cum7192.87192.89.04FalseNoneNoneFalseNoneFalse65022.9120
3471123123824Nonecode048 Percent (centering Charges)Cum11016.011016.02.26FalseNoneNoneFalseNoneFalse24896.160
3471124123824Nonecode0570 Percent (centering Charges)Cum7192.87192.840.7FalseNoneNoneFalseNoneFalse292746.960
3471125123824Nonecode06KSRB 2-2.2.3.1 :Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No. 2.2.3 Page No. 15 Vol.1 PWD SR & Appendix I page No.115)Cum9694.089694.085.98FalseNoneNoneFalseNoneFalse57970.59840
3471126123824Nonecode07KSRB 2.11 Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (Item No. 2.11 Page No. 18 Vol.1 PWD SR)Kg92140.7192140.714.98FalseNoneNoneFalseNoneFalse458860.73580
3471127123824Nonecode08KSRB 5-5.4: Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) . (Item No. 5.4 Page No. 9 Vol.2 PWD SR)Cum6580.676580.6717.43FalseNoneNoneFalseNoneFalse114701.07810
3471128123824Nonecode09KSRB 1-1.8: Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work (Item No. 1.8 Page No. 7 Vol.1 PWD SR)Cum474.0474.0183.14FalseNoneNoneFalseNoneFalse86808.360
3471129123824Nonecode10KSRB 6-6.33: Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Item No. 6.33 Page No. 17 Vol.2 PWD SR)Sqm1267.931267.93106.06FalseNoneNoneFalseNoneFalse134476.65580
3471130123824Nonecode11KSRB 8-8.3.1: Providing 15mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.2.1, Page No. 41, Vol.2)Sqm303.85303.85225.61FalseNoneNoneFalseNoneFalse68551.59850
3471131123824Nonecode12Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer inCharge. (Item No. 11.2, Page No. 77, Vol.2)Kg116.39116.398380.0FalseNoneNoneFalseNoneFalse975348.20
3471132123824Nonecode13Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Item No. 7.38, Page No. 26, Vol.2)Sqm585.04585.04590.76FalseNoneNoneFalseNoneFalse345618.23040
3471133123824Nonecode14KSRB 8-8.51 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(Item No. 8.51, Page No. 50, Vol.2)Sqm103.0103.0225.61FalseNoneNoneFalseNoneFalse23237.830
3471134123824Nonecode15KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(Item No. 8.54.1, Page No. 50, Vol.2)No75.1975.19106.06FalseNoneNoneFalseNoneFalse7974.65140
3471135123824Nonecode16KSRB 8-8.75.2 : Finishing walls with Premium Acrylic Smooth exterior paint of required shade : Old work (one coats applied @ 0.83 l/10 m²) including preparing the surface after thoroughly cleaning the surface to remove all dirt,dust and foreign matter , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.75.2, Page No. 53, Vol.2)No75.1975.19106.06FalseNoneNoneFalseNoneFalse7974.65140
3471136123824Nonecode17KSRB 11-11.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Item No. 11.6.1, Page No. 76, Vol.2)Sqm2711.992711.9922.5FalseNoneNoneFalseNoneFalse61019.7750
3471137123824Nonecode18KSRB 11-11.8.4:Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Item No. 11.8.4, Page No. 77, Vol.2)No25425.5825425.582.0FalseNoneNoneFalseNoneFalse50851.160
3471138123824Nonecode19KSRB 11-11.35.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications..(Item No. 11.35.1.1, Page No. 87,Kg465.56465.56240.0FalseNoneNoneFalseNoneFalse111734.40
3471139123824Nonecode20LT Control Panel for PHE Equipments, like raw water, treated water, sump water lift pumps including starter control operating system.Completely made by CRCA fabricated, powder coated paint finished front openable compartment for all feeders requirement with IP-54. Main Panel Incomer : MCCB TPN 63A with CBCT ELR & Ph indicators, meter section with all parameters as required Market price 100A 4 Wire 25kA 415V Aluminium busbars compartment. Outgoings: 63A MCCB feeder- 01No. Outgoings: 16A MPCB feeder - 01Nos Outgoings: 16A MPCB feeder - 03Nos Outgoings: 63/40A MCB feeder- 08NosNo75000.075000.01.0FalseNoneNoneFalseNoneFalse75000.00
3471140123824Nonecode21Sub panel-1 Incomer : MCB TPN 63A with CBCT ELR & Ph indicators, section with all parameters as required Market price 63A 4 Wire 16kA 415V Aluminium busbars compartment. Outgoings: 40/63A 4P MCB feeder- 10No. Outgoings: 32A Industrial socket-02Nos. Outgoings: 16A Industrial socket-02Nos.No35000.035000.01.0FalseNoneNoneFalseNoneFalse35000.00
3471141123824Nonecode22LT Cables Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included. 3.5Cx50 Sqmm Al Ar cableMtr300.0300.030.0FalseNoneNoneFalseNoneFalse9000.00
3471142123824Nonecode234Cx25 Sqmm Al Ar cableMtr180.0180.020.0FalseNoneNoneFalseNoneFalse3600.00
3471143123824Nonecode244Cx16 Sqmm Al Ar cableMtr120.0120.020.0FalseNoneNoneFalseNoneFalse2400.00
3471144123824Nonecode254Cx10 Sqmm Cu Ar cableMtr332.0332.01.0FalseNoneNoneFalseNoneFalse332.00
3471145123824Nonecode264Cx6.0 Sqmm Cu Ar cableMtr256.0256.01.0FalseNoneNoneFalseNoneFalse256.00
3471146123824Nonecode273Cx6.0 Sqmm Cu Un Ar cableMtr316.0316.01.0FalseNoneNoneFalseNoneFalse316.00
3471147123824Nonecode283Cx4.0 Sqmm Cu Un Ar cableMtr300.0300.01.0FalseNoneNoneFalseNoneFalse300.00
3471148123824Nonecode29Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class. 3.5Cx50 Sqmm Al Ar cableSet200.0200.02.0FalseNoneNoneFalseNoneFalse400.00
3471149123824Nonecode304Cx25 Sqmm Al Ar cableSet67.267.22.0FalseNoneNoneFalseNoneFalse134.40
3471150123824Nonecode314Cx16 Sqmm Al Ar cableSet67.267.22.0FalseNoneNoneFalseNoneFalse134.40
3471151123824Nonecode324Cx10 Sqmm Cu Ar cableSet54.454.42.0FalseNoneNoneFalseNoneFalse108.80
3471152123824Nonecode334Cx6.0 Sqmm Cu Ar cableSet54.454.42.0FalseNoneNoneFalseNoneFalse108.80
3471153123824Nonecode343Cx6.0 Sqmm Cu Un Ar cableSet54.454.42.0FalseNoneNoneFalseNoneFalse108.80
3471154123824Nonecode353Cx4.0 Sqmm Cu Un Ar cableSet54.454.42.0FalseNoneNoneFalseNoneFalse108.80
3471155123824Nonecode36Supply & installation of Tinned Copper lugs crimping & wiring to terminal point. 70 Sqmm Al Ar cable (tinned copper lug)Set250.0250.02.0FalseNoneNoneFalseNoneFalse500.00
3471156123824Nonecode3725 Sqmm Al Ar cable (tinned copper lug)Set16.016.02.0FalseNoneNoneFalseNoneFalse32.00
3471157123824Nonecode3816 Sqmm Al Ar cable (tinned copper lug)Set9.959.952.0FalseNoneNoneFalseNoneFalse19.90
3471158123824Nonecode3910 Sqmm Cu Ar cable (tinned copper lug)Set6.46.41.0FalseNoneNoneFalseNoneFalse6.40
3471159123824Nonecode406.0 Sqmm Cu Ar cable (tinned copper lug)Set5.65.61.0FalseNoneNoneFalseNoneFalse5.60
3471160123824Nonecode416.0 Sqmm Cu Un Ar cable (tinned copper lug)Set5.65.61.0FalseNoneNoneFalseNoneFalse5.60
3471161123824Nonecode424.0 Sqmm Cu Un Ar cable (tinned copper lug)Set5.65.61.0FalseNoneNoneFalseNoneFalse5.60
3471162123824Nonecode43PVC conduits & Accessories Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws. 19/20mm dia PVC 2mm thick conduit CSR Electrical SR-2022-23, ITEM NO:1.1.1 ,CH-1, PAGE NO-1Mtr68.068.010.0FalseNoneNoneFalseNoneFalse680.00
3471163123824Nonecode4425mm dia PVC 2mm thick conduit CSR Electrical SR-2022-23, ITEM NO:1.1.2 ,CH-1, PAGE NO-1Mtr80.080.010.0FalseNoneNoneFalseNoneFalse800.00
3471164123824Nonecode45Point wiring using Copper wire with switch Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit. 1 Light point upto 3Mtr from switch board CSR Electrical SR-2022-23, ITEM NO:2.1.1 ,CH-1, PAGE NO-2Nos276.0276.01.0FalseNoneNoneFalseNoneFalse276.00
3471165123824Nonecode461 Light point above 3M upto 6Mtr from switch board CSR Electrical SR-2022-23, ITEM NO:2.1.2 ,CH-1, PAGE NO-3Nos386.0386.01.0FalseNoneNoneFalseNoneFalse386.00
3471166123824Nonecode471 Light point above 6M upto 10Mtr from switch board CSR Electrical SR-2022-23, ITEM NO:2.1.3 ,CH-1, PAGE NO-3Nos567.0567.01.0FalseNoneNoneFalseNoneFalse567.00
3471167123824Nonecode482 Light point above 3Mtr upto 6Mtr from switch board CSR Electrical SR-2022-23, ITEM NO:2.1.4 ,CH-1, PAGE NO-3Nos721.0721.01.0FalseNoneNoneFalseNoneFalse721.00
3471168123824Nonecode492 Light point above 6Mtr upto 10Mtr from switch board CSR Electrical SR-2022-23, ITEM NO:2.1.4 ,CH-1, PAGE NO-3Nos721.0721.01.0FalseNoneNoneFalseNoneFalse721.00
3471169123824Nonecode503 Light point above 6Mtr upto 10Mtr from switch board CSR Electrical SR-2022-23, ITEM NO:2.1.5 ,CH-1, PAGE NO-3No1054.01054.03.0FalseNoneNoneFalseNoneFalse3162.00
3471170123824Nonecode51Circuit main wiring Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit. 1.0 Sqmm Cu FRLS wire CSR Electrical SR-2022-23, ITEM NO:2.3.1 ,CH-1, PAGE NO-3Mtr18.018.0300.0FalseNoneNoneFalseNoneFalse5400.00
3471171123824Nonecode521.5 Sqmm Cu FRLS wire CSR Electrical SR-2022-23, ITEM NO:2.3.2 ,CH-1, PAGE NO-3Mtr26.026.0300.0FalseNoneNoneFalseNoneFalse7800.00
3471172123824Nonecode532.5 Sqmm Cu FRLS wire CSR Electrical SR-2022-23, ITEM NO:2.3.3 ,CH-1, PAGE NO-3Mtr40.040.0300.0FalseNoneNoneFalseNoneFalse12000.00
3471173123824Nonecode544.0 Sqmm Cu FRLS wire CSR Electrical SR-2022-23, ITEM NO:2.3.4 ,CH-1, PAGE NO-3Mtr59.059.050.0FalseNoneNoneFalseNoneFalse2950.00
3471174123824Nonecode556.0 Sqmm Cu FRLS wire CSR Electrical SR-2022-23, ITEM NO:2.3.4 ,CH-1, PAGE NO-3Mtr115.0115.050.0FalseNoneNoneFalseNoneFalse5750.00
3471175123824Nonecode56Switches & sockets outlets in Existing modular box 6A one way switch CSR Electrical SR-2022-23, ITEM NO:3.6.1 ,CH-3, PAGE NO-5Nos88.088.04.0FalseNoneNoneFalseNoneFalse352.00
3471176123824Nonecode576A 5Pin socket CSR Electrical SR-2022-23, ITEM NO:3.6.3 ,CH-3, PAGE NO-5Nos162.0162.02.0FalseNoneNoneFalseNoneFalse324.00
3471177123824Nonecode58Stepped fan regulator CSR Electrical SR-2022-23, ITEM NO:3.6.4 ,CH-3, PAGE NO-5Nos313.0313.02.0FalseNoneNoneFalseNoneFalse626.00
3471178123824Nonecode596/16A Universal socket CSR Electrical SR-2022-23, ITEM NO:3.6.11 ,CH-3, PAGE NO-5Nos249.0249.02.0FalseNoneNoneFalseNoneFalse498.00
3471179123824Nonecode60Light fixture Supply & fixing of 50W LED light fixture IP 65, included screws accessoris Etc..Considered outdoor type light fitting for equivalent. CSR Electrical SR-2022-23, ITEM NO:11.9.1, PAGE NO-37Nos7390.07390.010.0FalseNoneNoneFalseNoneFalse73900.00
3471180123824Nonecode61Earthing 25x6mm GI Earth StripMtr92.092.060.0FalseNoneNoneFalseNoneFalse5520.00
3471181123824Nonecode628.0 SWG GI bare wireMtr15.215.250.0FalseNoneNoneFalseNoneFalse760.00
3471182123824Nonecode63Supply & installation of Cable Trays fixed with MS angles, hitech & anchor fastner supports at interval 0.9M interval shall be included complete run below ceiling/wall. Supply & installation of GI Ladder type cable tray 300x50mmMtr400.0400.020.0FalseNoneNoneFalseNoneFalse8000.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17202657690000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17202657690000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17202657690000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17202657690000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17202657690000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneProposals for subcontracting components of works amounting to more than 20% of the contract price (for each, the qualifications and experience of the identified sub-contractor in the relevant fields should be attached)NoneNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Valid Contractror Registration CertificateTrueTechnical Bid
Annual Turnover Certificate last 5 Year in laksh i.e.2018-19 to 2022-23TrueTechnical Bid
Bid Capacity in lakhsTrueTechnical Bid
Work done certificate in similar nature of Work done for 50percentage of the estimate Amount within the Last 5 Years.TrueTechnical Bid
Thirty Percentage Of Tender Amount Line of Credit Unconditional From Nationalised or scheduled Bank.TrueTechnical Bid
Copy of DD From Nationalised or scheduled Bank for difference amountTrueTechnical Bid
Site visit certificate issued by junior engineer tp BelagaliTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone