| 1720266153000 | 0 | None | None | Other Works | Construction of office room in SWM site | 722151.28 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3471207 | 123827 | None | code01 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. . (PWD Comman SR 2023-24,V-1 Item no. 1.4.1, Page No.05) | Cum | 249.26 | 249.26 | 9.99 | False | None | None | False | None | False | 2490.1074 | 0 | | 3471208 | 123827 | None | code02 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (PWD SR Vol-01, 2023-24, Item no. 2.1.4, Page No.15) | Cum | 6403.51 | 6403.51 | 4.97 | False | None | None | False | None | False | 31825.4447 | 0 | | 3471209 | 123827 | None | code03 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) (PWD SR Vol-02, 2023-24, Item no.5.1.1, Page No.9) | Cum | 5779.33 | 5779.33 | 14.17 | False | None | None | False | None | False | 81893.1061 | 0 | | 3471210 | 123827 | None | code04 | Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 ( PWD SR 2023-24 Vol-3 , P.No -17 ,I No - 3.6 ) | Cum | 507.79 | 507.79 | 14.78 | False | None | None | False | None | False | 7505.1362 | 0 | | 3471211 | 123827 | None | code05 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD SR, Vol.1, 2023-24, Item no. 2.41, Page No.16) | Cum | 8463.86 | 8463.86 | 1.73 | False | None | None | False | None | False | 14642.4778 | 0 | | 3471212 | 123827 | None | code06 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD SR, Vol.1, 2023-24, Item no. 2.41, Page No.16) | Cum | 13969.48 | 13969.48 | 4.11 | False | None | None | False | None | False | 57414.5628 | 0 | | 3471213 | 123827 | None | code07 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD SR, Vol.1, 2023-24, Item no. 2.41, Page No.16) | Cum | 12326.01 | 12326.01 | 0.86 | False | None | None | False | None | False | 10600.3686 | 0 | | 3471214 | 123827 | None | code08 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD SR, Vol.1, 2023-24, Item no. 2.41, Page No.16) | Cum | 13147.74 | 13147.74 | 2.46 | False | None | None | False | None | False | 32343.4404 | 0 | | 3471215 | 123827 | None | code09 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD SR, Vol.1, 2023-24, Item no. 2.41, Page No.16) | Cum | 12326.01 | 12326.01 | 4.3 | False | None | None | False | None | False | 53001.843 | 0 | | 3471216 | 123827 | None | code10 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings (PWD SR 2023-24, Vol-1 , Item No. 2.11a, Page No. 18) | Tonne | 92140.71 | 92140.71 | 1.346 | False | None | None | False | None | False | 124021.39566 | 0 | | 3471217 | 123827 | None | code11 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (PWD Vol-02 SR 2023-24, Item no. 6.2, Page No.13) | Cum | 8466.6 | 8466.6 | 11.39 | False | None | None | False | None | False | 96434.574 | 0 | | 3471218 | 123827 | None | code12 | Providing and fixing M.S. grills of required pattern in frames of indows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding (PWD SR 2023-24, Vol-02, Item no. 11.34A, Page No.85) | Kg | 173.04 | 173.04 | 56.7 | False | None | None | False | None | False | 9811.368 | 0 | | 3471219 | 123827 | None | code13 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (PWD SR 2023-24, Vol-02, Item no. 12.90, Page No.110) | Sqm | 6936.02 | 6936.02 | 2.7 | False | None | None | False | None | False | 18727.254 | 0 | | 3471220 | 123827 | None | code14 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (PWD SR 2023-24, Vol-02, Item no. 12.11, Page No.99) | Cum | 142216.22 | 142216.22 | 0.11 | False | None | None | False | None | False | 15643.7842 | 0 | | 3471221 | 123827 | None | code15 | Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ). (PWD SR 2023-24, Vol-02 Item no. 12.15, Page No.100) | Sqm | 7667.32 | 7667.32 | 2.0 | False | None | None | False | None | False | 15334.64 | 0 | | 3471222 | 123827 | None | code16 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) inished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR Vol-02, 2023-24, Item no.8.8, Page No.42) | Sqm | 382.13 | 382.13 | 170.94 | False | None | None | False | None | False | 65321.3022 | 0 | | 3471223 | 123827 | None | code17 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm (PWD SR Vol-02, 2023-24, Item no.9.12.2, Page No.60) | Sqm | 1179.35 | 1179.35 | 12.96 | False | None | None | False | None | False | 15284.376 | 0 | | 3471224 | 123827 | None | code18 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR Vol-02, 2023-24, Item no. 8.40 Page No.48) | Sqm | 118.45 | 118.45 | 2.7 | False | None | None | False | None | False | 319.815 | 0 | | 3471225 | 123827 | None | code19 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as perspecifications and as per directions of Engineer-in-charge. (PWD SR Vol-02, 2023-24, Item no. 8.27, Page No.45) | Sqm | 54.59 | 54.59 | 170.94 | False | None | None | False | None | False | 9331.6146 | 0 | | 3471226 | 123827 | None | code20 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR Vol-02, 2023-24, Item no. 8.28, Page No.45) | Sqm | 91.67 | 91.67 | 170.94 | False | None | None | False | None | False | 15670.0698 | 0 | | 3471227 | 123827 | None | code21 | Providing and supplying office Table of size 0.75 x 1.2m x 1m ht with locks etc complete as per engineer direction | No | 8000.0 | 8000.0 | 1.0 | False | None | None | False | None | False | 8000.0 | 0 | | 3471228 | 123827 | None | code22 | Providing and supplying office chair etc complete as per engineer direction | No | 3000.0 | 3000.0 | 4.0 | False | None | None | False | None | False | 12000.0 | 0 | | 3471229 | 123827 | None | code23 | Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary, 19/20 mm dia 2 mm thick, (PWD Electrical CSR 2023-24, IN-1.2.1, PN-2) | Mtr | 67.98 | 67.98 | 45.0 | False | None | None | False | None | False | 3059.1 | 0 | | 3471230 | 123827 | None | code24 | Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary, 25 mm dia 2 mm thick (PWD Electrical CSR 2023-24, IN-1.2.2, PN-2), | Sqm | 80.34 | 80.34 | 30.0 | False | None | None | False | None | False | 2410.2 | 0 | | 3471231 | 123827 | None | code25 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Electrical SR 2021-22, Short point upto 3m from tapping point to out let via switch box. (PWD Electrical CSR 2021-2022, IN-2.2.1, PN-5), Short point upto 3m from tapping point to out let via switch box. | Mtr | 277.07 | 277.07 | 20.0 | False | None | None | False | None | False | 5541.4 | 0 | | 3471232 | 123827 | None | code26 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Electrical SR 2021-22, Short point upto 3m from tapping point to out let via switch box. (PWD Electrical CSR 2023-24, IN-2.2.2, PN-5), Medium point above 3m upto 6m from tapping point to out let via switch box. | Point | 390.37 | 390.37 | 10.0 | False | None | None | False | None | False | 3903.7 | 0 | | 3471233 | 123827 | None | code27 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Electrical SR 2021-22, Short point upto 3m from tapping point to out let via switch box. (PWD Electrical CSR 2023-24, IN-2.2.2, PN-5), Long point above 6m upto 10m from tapping point to out let via switch box | Mtr | 390.37 | 390.37 | 10.0 | False | None | None | False | None | False | 3903.7 | 0 | | 3471234 | 123827 | None | code28 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Electrical SR 2021-22, Short point upto 3m from tapping point to out let via switch box. (PWD Electrical CSR 2023-24, IN-2.2.2, PN-5), Long point above 6m upto 10m from tapping point to out let via switch box | Point | 571.65 | 571.65 | 10.0 | False | None | None | False | None | False | 5716.5 | 0 |
|