createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1720251767980
version9
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd32500.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose18-07-2024 16:18:58
tenderQueryClose16-07-2024 16:30:00
technicalBidOpen19-07-2024 17:00:00
publishedDate06-07-2024 17:30:34
publishedByPostTP_CO_KDG
publishedByUserKPE14508 - FEROZ KHAN
bidValidityPeriod90
noOfCalls3
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnTrue
percentageRateTypeTextNone
contactPersonFEROZKHAN
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08391220049
mobileNumber9902857458
tenderSupplierListNone
tenderSchedule
createdTs1720251767982
version20
createdDateNone
modifiedDateNone
tenderNumberDMA/2023-24/WS/WORK_INDENT11406/CALL-3
titleWater supply related works in ward no 09 and ward 03, ward no 12, ward 05 and ward 20 in Kudligi Town Limits
descriptionInstallation of motor pump to the bore well drilled near Masjid Saab house in Ward No. 9. And Installation of motor pump by drilling bore well near Sharad School of Ward 03. And To provide drinking water supply to the residents near Beldar Kotresha house in Ward No. 12, borewell drilling, installation of motor pump, pipeline, mini tank construction and linking.and Construction of pipeline from near Panchacharya Kalyan Mandap to Airtel Tower in Ward No. 5 Construction of pipeline from Ward No. 20 Govindagiri vadralli Marappa Kana to Mallajjana house front.
categoryWORKS
categoryTextWorks
ecv1086358.81
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2482
locationNameDMA Town Panchayat Kudligi
provisionalAmount1300000.0
groupOverheadTotalNone
fileNumberTPK/15FTG/23-24/PACKAGE-05
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17202517680001NoneNoneWater supply/sewage linesWater supply related works in ward no 09 and ward 03, ward no 12, ward 05 and ward 20 in Kudligi Town Limits1086358.81
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3465960123625Noneitem_code1Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For: Heavey Duty GI pipe of 50mm dia Heavy Duty GI pipe of 50mm diaMtr712.95712.95150.0FalseNoneNoneFalseNoneFalse106942.50
3465961123625Noneitem_code2Lowering, Laying and Jointing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) for etc. complete. 50mm diaMtr152.25152.25150.0FalseNoneNoneFalseNoneFalse22837.50
3465962123625Noneitem_code3Providing and fixing GI union in existing GI pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required etc. complete for:Each152.25152.2545.0FalseNoneNoneFalseNoneFalse6851.250
3465963123625Noneitem_code4Supply and delivery at site wrought middle steel (galvanized) GI hexagonal nipple confirming to IS 1239-II, 1991 with latest amendments if any.For 25 mm dia GI hexagonal nippleEach135.45135.4555.0FalseNoneNoneFalseNoneFalse7449.750
3465964123625Noneitem_code5Dismantling of Cement Concrete Pavement Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 m3 in volume and stock piling at designated locations and disposal of dismantled materials and stacking serviceable and unserviceable materials separatelyCum591.15591.1511.14FalseNoneNoneFalseNoneFalse6585.4110
3465965123625Noneitem_code6Disposal off the excess excavated earth of all types by vehicle including loading, unloading with all lead and lifts, labour, HOM of machineries etc. for:Distance of 1 to 2 kmCum82.9582.9511.14FalseNoneNoneFalseNoneFalse924.0630
3465966123625Noneitem_code7Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.In all kinds of soils. Depth upto 1.50mCum493.5493.540.84FalseNoneNoneFalseNoneFalse20154.540
3465967123625Noneitem_code8Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.90mm(weight of pipe -0.917 kg)6 Kg/m2Mtr270.9270.9165.0FalseNoneNoneFalseNoneFalse44698.50
3465968123625Noneitem_code9Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specificationsCum128.1128.144.55FalseNoneNoneFalseNoneFalse5706.8550
3465969123625Noneitem_code10Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6961.56961.57.43FalseNoneNoneFalseNoneFalse51723.9450
3465970123625Noneitem_code11Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For: Medium Duty GI pipe of 100mm diaMtr1307.251307.2525.0FalseNoneNoneFalseNoneFalse32681.250
3465971123625Noneitem_code12Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. Depth upto 1.50mCum508.2508.2151.88FalseNoneNoneFalseNoneFalse77185.4160
3465972123625Noneitem_code13Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.90mm(weight of pipe -1.313 kg)6 Kg/m2Mtr270.9270.9450.0FalseNoneNoneFalseNoneFalse121905.00
3465973123625Noneitem_code14Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specificationsCum168.0168.0121.5FalseNoneNoneFalseNoneFalse20412.00
3465974123625Noneitem_code15Providing and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of Ductile Iron (DI) conforming ti IS-1865 with the latest amendments and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 with the latest amendments only. The stem sealing should be with toroidal sealing rings (minimum 2 " O " rings). Body and bonnet should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. For PN-10: (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) etc. complete For Suilce Valve of PN -10.0 and 80mmEach10912.6510912.652.0FalseNoneNoneFalseNoneFalse21825.30
3465975123625Noneitem_code16Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. etc. completeEach5552.45552.41.0FalseNoneNoneFalseNoneFalse5552.40
3465976123625Noneitem_code17Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)00 To 50 MtrMtr388.5388.550.0FalseNoneNoneFalseNoneFalse19425.00
3465977123625Noneitem_code18Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)50 to 100 MtrMtr487.5487.550.0FalseNoneNoneFalseNoneFalse24375.00
3465978123625Noneitem_code19Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)100 To 150 MtrMtr517.65517.6510.0FalseNoneNoneFalseNoneFalse5176.50
3465979123625Noneitem_code20Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. 200mm6 Kg/m2(weight of pipe -6.233 kg)Mtr1015.351015.3518.0FalseNoneNoneFalseNoneFalse18276.30
3465980123625Noneitem_code21Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. 3.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00"Each29518.6529518.652.0FalseNoneNoneFalseNoneFalse59037.30
3465981123625Noneitem_code22Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x4 SqmMtr141.75141.75100.0FalseNoneNoneFalseNoneFalse14175.00
3465982123625Noneitem_code23Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 50 mmEach1312.51312.51.0FalseNoneNoneFalseNoneFalse1312.50
3465983123625Noneitem_code24Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete. 3 to 6 HP pumpsEach10027.510027.52.0FalseNoneNoneFalseNoneFalse20055.00
3465984123625Noneitem_code25Supply and delivery of galvanized mild steel tubes of 6mtr standard length heavy duty (C Class) as per IS 1239 (Part-I) 1990 with latest amendments with ISI Mark (one end fitted with Heavy Duty collar and other end fitted with protective cover) 50 mmEach3202.53202.512.0FalseNoneNoneFalseNoneFalse38430.00
3465985123625Noneitem_code26Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work.Job6825.06825.01.0FalseNoneNoneFalseNoneFalse6825.00
3465986123625Noneitem_code27Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work.Job1417.51417.51.0FalseNoneNoneFalseNoneFalse1417.50
3465987123625Noneitem_code28Labour charges for providing connection using insulated sheathed steel wire cable as per IS 1554/ 1988 with latest amendments from KPTCL pole to meter board unit, with all necessary materials ,tools and equipments,as per specificationswith testing of as per instructions of engineer incharge of work. 3 x 10 sqmm (suitable for over head mains)Mtr173.25173.2550.0FalseNoneNoneFalseNoneFalse8662.50
3465988123625Noneitem_code29Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.In all kinds of soils. Depth upto 1.50mCum493.5493.533.75FalseNoneNoneFalseNoneFalse16655.6250
3465989123625Noneitem_code30Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.90mm(weight of pipe -1.313 kg)6 Kg/m2Mtr270.9270.9100.0FalseNoneNoneFalseNoneFalse27090.00
3465990123625Noneitem_code31Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specificationsCum128.1128.127.0FalseNoneNoneFalseNoneFalse3458.70
3465991123625Noneitem_code32Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. etc. completeEach5552.45552.41.0FalseNoneNoneFalseNoneFalse5552.40
3465992123625Noneitem_code33Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)00 to 50.00 Mtr DepthMtr388.5388.550.0FalseNoneNoneFalseNoneFalse19425.00
3465993123625Noneitem_code34Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)50to 100.00 Mtr DepthMtr487.2487.250.0FalseNoneNoneFalseNoneFalse24360.00
3465994123625Noneitem_code35Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)100 to 150.00 Mtr DepthMtr517.65517.6510.0FalseNoneNoneFalseNoneFalse5176.50
3465995123625Noneitem_code36Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. 200mm6 Kg/m2(weight of pipe -6.233 kg)Mtr1015.351015.3512.0FalseNoneNoneFalseNoneFalse12184.20
3465996123625Noneitem_code37Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. 6.50 HP - 155 LPM @ 84 m = 10 STG Outlet Dia - 2.00"Each32312.732312.71.0FalseNoneNoneFalseNoneFalse32312.70
3465997123625Noneitem_code38Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x4 SqmMtr141.75141.7580.0FalseNoneNoneFalseNoneFalse11340.00
3465998123625Noneitem_code39Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 50 mmEach1312.51312.51.0FalseNoneNoneFalseNoneFalse1312.50
3465999123625Noneitem_code40Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete. 3 to 6 HP pumpsEach10027.510027.51.0FalseNoneNoneFalseNoneFalse10027.50
3466000123625Noneitem_code41Supply and delivery of galvanized mild steel tubes of 6mtr standard length heavy duty (C Class) as per IS 1239 (Part-I) 1990 with latest amendments with ISI Mark (one end fitted with Heavy Duty collar and other end fitted with protective cover) 50 mmEach3202.53202.512.0FalseNoneNoneFalseNoneFalse38430.00
3466001123625Noneitem_code42Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work.Job6825.06825.01.0FalseNoneNoneFalseNoneFalse6825.00
3466002123625Noneitem_code43Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work.Job1417.51417.51.0FalseNoneNoneFalseNoneFalse1417.50
3466003123625Noneitem_code44Labour charges for providing connection using insulated sheathed steel wire cable as per IS 1554/ 1988 with latest amendments from KPTCL pole to meter board unit, with all necessary materials ,tools and equipments,as per specificationswith testing of as per instructions of engineer incharge of work. 3 x 10 sqmm (suitable for over head mains)Mtr173.25173.2530.0FalseNoneNoneFalseNoneFalse5197.50
3466004123625Noneitem_code45Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum254.1254.12.78FalseNoneNoneFalseNoneFalse706.3980
3466005123625Noneitem_code46Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum5947.25947.20.8FalseNoneNoneFalseNoneFalse4757.760
3466006123625Noneitem_code47Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum5891.555891.551.28FalseNoneNoneFalseNoneFalse7541.1840
3466007123625Noneitem_code48Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Basement in CM 5.6Cum6770.46770.41.54FalseNoneNoneFalseNoneFalse10426.4160
3466008123625Noneitem_code49Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6639.156639.150.8FalseNoneNoneFalseNoneFalse5311.320
3466009123625Noneitem_code50Providing Flush / Ruled/ Struck or weathered pointing Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge.Sqm180.6180.63.6FalseNoneNoneFalseNoneFalse650.160
3466010123625Noneitem_code51Supply and erection of 2.50 mtr height ready made latrins/pumphouse/water cirsterns incluiding conveying the same carefully to work spot, loading and unloading at both destinations with all lead and lift etc complete.Each23372.023372.01.0FalseNoneNoneFalseNoneFalse23372.00
3466011123625Noneitem_code52Erection and positioning of RCC Hume pipe pump house/Cistern on size stone masory platform including transportation charges and handling,finishing with all necessary tools ,plants and materials etc.,complete as directed by the Engineer in charge of the work.Job1976.11976.11.0FalseNoneNoneFalseNoneFalse1976.10
3466012123625Noneitem_code53Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete.:Heavy Duty GI pipe of 32mm diaMtr449.4449.46.0FalseNoneNoneFalseNoneFalse2696.40
3466013123625Noneitem_code54Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS markFor 32 mm dia GM (Copper alloy) Gate valvesEach1404.91404.91.0FalseNoneNoneFalseNoneFalse1404.90
3466014123625Noneitem_code55Steel Bib cockEach186.44186.444.0FalseNoneNoneFalseNoneFalse745.760
3466015123625Noneitem_code56Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.In all kinds of soils. Depth upto 1.50mCum493.5493.525.31FalseNoneNoneFalseNoneFalse12490.4850
3466016123625Noneitem_code57Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.90mm(weight of pipe -1.313 kg)6 Kg/m2Mtr270.9270.975.0FalseNoneNoneFalseNoneFalse20317.50
3466017123625Noneitem_code58Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specificationsCum128.1128.120.25FalseNoneNoneFalseNoneFalse2594.0250
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17202517680000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17202517680000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17202517680000NoneNoneELIGIBILITYNot ApplicableNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneTo qualify for award of this contract each tenderer in its name should have in the last five years in any one year Satisfactorily completed as prime contractor at least one similar work such as of value not less than Rs 6.50 LakhsPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneValid PWD Contractor Registration CertificateCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneValid GST Registration CertificateCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneLiquid assets and or availability of credit facilities of no less than Rs 3.90 Lakhs Credit lines/ letters of credit/ certificates from banks for meeting the fund requirement etc. (Banker Certificate is in prescribed format provided in bid documentFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneTo qualify for award of this contract each tenderer in its name should have in the last five years i.e,2019-20 to 2023-24achieved in at least two financial years a average minimum financial turnover of Rs 13.00 LakhsFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneUpload all documents as per Technical Criteria and Bid DocumentOthersTechnical Criteria and Bid Document
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Technical Criteria and Bid Document
NoneNoneNoneNoneContractors must submit the agreement with Approved Bore well agency holder with Form-7A CertificateOthersForm-7A Certificate
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Form-7A Certificate
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Upload all documents as per Technical Criteria and Bid DocumentTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone