createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1720250258122
version7
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyRESERVED
invitingStrategyTextReserved
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd16250.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose18-07-2024 16:00:00
tenderQueryClose16-07-2024 16:30:00
technicalBidOpen19-07-2024 17:00:00
publishedDate06-07-2024 17:15:28
publishedByPostTP_CO_KDG
publishedByUserKPE14508 - FEROZ KHAN
bidValidityPeriod90
noOfCalls2
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnTrue
percentageRateTypeTextNone
contactPersonFEROZKHAN
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9902857458
tenderSupplierListNone
tenderSchedule
createdTs1720250258124
version14
createdDateNone
modifiedDateNone
tenderNumberDMA/2023-24/WS/WORK_INDENT11409/CALL-2
titleConstruction of pipeline from Hospet Road Bayalu Anjaneya Temple to Kumbar Oni in Ward No. 15 In Ward No. 16, Rajiv Gandhi Nagar, drilling a borewell for drinking water, installing a motor pump, installing a pipeline, constructing a mini tank and linking it. Installation of pipeline for water supply to Government Post Matric Boys College in Ward No. 01. Installing a pipe line to the drinking water tank at KSRTC bus stand and repairing the tank.
descriptionConstruction of pipeline from Hospet Road Bayalu Anjaneya Temple to Kumbar Oni in Ward No. 15 In Ward No. 16, Rajiv Gandhi Nagar, drilling a borewell for drinking water, installing a motor pump, installing a pipeline, constructing a mini tank and linking it. Installation of pipeline for water supply to Government Post Matric Boys College in Ward No. 01. Installing a pipe line to the drinking water tank at KSRTC bus stand and repairing the tank.
categoryWORKS
categoryTextWorks
ecv1088273.05
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2482
locationNameDMA Town Panchayat Kudligi
provisionalAmount1300000.0
groupOverheadTotalNone
fileNumberTPK/15FTG/23-24/PACKAGE-06
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17202502580001NoneNoneWater supply/sewage linesConstruction of pipeline from Hospet Road Bayalu Anjaneya Temple to Kumbar Oni in Ward No. 15 In Ward No. 16, Rajiv Gandhi Nagar, drilling a borewell for drinking water, installing a motor pump, installing a pipeline, constructing a mini tank and linking it. Installation of pipeline for water supply to Government Post Matric Boys College in Ward No. 01. Installing a pipe line to the drinking water tank at KSRTC bus stand and repairing the tank.1088273.05
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3465093123597Noneitem_code1Dismantling of Structures Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead Prestressed / Reinforced cement concrete grade M-20 & aboveCum2514.752514.750.9375FalseNoneNoneFalseNoneFalse2357.5781250
3465094123597Noneitem_code2Dubbing out on old irregular walls average 10mm thick and making good the surface with cement mortar 1:3 including curing cost of materials, labour, complete as per specifications.Cum226.8226.816.0FalseNoneNoneFalseNoneFalse3628.80
3465095123597Noneitem_code3Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 100mm wideSqm46.246.216.8FalseNoneNoneFalseNoneFalse776.160
3465096123597Noneitem_code4Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Page 16 Item No. PWD CSR Vol. 1)Cum9958.729958.720.625FalseNoneNoneFalseNoneFalse6224.20
3465097123597Noneitem_code5Steel Fabrication- Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.t82.9682.9656.25FalseNoneNoneFalseNoneFalse4666.50
3465098123597Noneitem_code6Supply and fixing of SFRC machinhole cover (Medium Duty) made as per IS to suit existing damaged machinhole cover after removing the debries from inside and outside the existing machinhole etc. with all lead and lifts. Heavy duty (Page 208 SL No. 16.61.2 BWSSB CSR Vol. 5)Each1294.651294.651.0FalseNoneNoneFalseNoneFalse1294.650
3465099123597Noneitem_code7Food Graded Water Proofing Membrane Providing and laying water proofing treatment to the Water tanks & Liquid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50% applied @ 1.5 kg/m2 for internal side waterproofing in two layers with waiting period of 4-6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specificationSqm532.35532.3516.8FalseNoneNoneFalseNoneFalse8943.480
3465100123597Noneitem_code8Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.Sqm937.65937.6526.88FalseNoneNoneFalseNoneFalse25204.0320
3465101123597Noneitem_code9Dismantling of Cement Concrete Pavement Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 m3 in volume and stock piling at designated locations and disposal of dismantled materials and stacking serviceable and unserviceable materials separatelyCum591.15591.156.75FalseNoneNoneFalseNoneFalse3990.26250
3465102123597Noneitem_code10Disposal off the excess excavated earth of all types by vehicle including loading, unloading with all lead and lifts, labour, HOM of machineries etc. for:Distance of 1 to 2 kmCum82.9582.956.75FalseNoneNoneFalseNoneFalse559.91250
3465103123597Noneitem_code11Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.In all kinds of soils. Depth upto 1.50mCum493.5493.5151.875FalseNoneNoneFalseNoneFalse74950.31250
3465104123597Noneitem_code12Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.6 Kg/m2: 63mm(weight of pipe -0.662 kg)Mtr145.95145.95150.0FalseNoneNoneFalseNoneFalse21892.50
3465105123597Noneitem_code13Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.6 Kg/m2: 75mm(weight of pipe -0.662 kg)Mtr201.6201.6200.0FalseNoneNoneFalseNoneFalse40320.00
3465106123597Noneitem_code14Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specificationsCum128.1128.1121.5FalseNoneNoneFalseNoneFalse15564.150
3465107123597Noneitem_code15Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For: Medium Duty GI pipe of 100mm diaMtr449.4449.430.0FalseNoneNoneFalseNoneFalse13482.00
3465108123597Noneitem_code16Providing and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of Ductile Iron (DI) conforming ti IS-1865 with the latest amendments and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 with the latest amendments only. The stem sealing should be with toroidal sealing rings (minimum 2 " O " rings). Body and bonnet should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. For PN-10: (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) etc. complete For Suilce Valve of PN -10.0 and 80mmEach8413.658413.652.0FalseNoneNoneFalseNoneFalse16827.30
3465109123597Noneitem_code17Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6961.56961.54.5FalseNoneNoneFalseNoneFalse31326.750
3465110123597Noneitem_code18Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay (non modular) bricks of class designation 3.5Each1791.31791.31.0FalseNoneNoneFalseNoneFalse1791.30
3465111123597Noneitem_code19Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For: Medium Duty GI pipe of 100mm diaMtr1307.251307.2525.0FalseNoneNoneFalseNoneFalse32681.250
3465112123597Noneitem_code20Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. Depth upto 1.50mCum508.2508.2151.88FalseNoneNoneFalseNoneFalse77185.4160
3465113123597Noneitem_code21Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.90mm(weight of pipe -1.313 kg)6 Kg/m2Mtr270.9270.9450.0FalseNoneNoneFalseNoneFalse121905.00
3465114123597Noneitem_code22Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specificationsCum168.0168.0121.5FalseNoneNoneFalseNoneFalse20412.00
3465115123597Noneitem_code23Providing and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of Ductile Iron (DI) conforming ti IS-1865 with the latest amendments and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 with the latest amendments only. The stem sealing should be with toroidal sealing rings (minimum 2 " O " rings). Body and bonnet should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. For PN-10: (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) etc. complete For Suilce Valve of PN -10.0 and 80mmEach10912.6510912.652.0FalseNoneNoneFalseNoneFalse21825.30
3465116123597Noneitem_code24Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For: Medium Duty GI pipe of 100mm diaMtr1307.251307.2520.0FalseNoneNoneFalseNoneFalse26145.00
3465117123597Noneitem_code25Dismantling of Cement Concrete Pavement Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 m3 in volume and stock piling at designated locations and disposal of dismantled materials and stacking serviceable and unserviceable materials separatelyCum591.15591.153.15FalseNoneNoneFalseNoneFalse1862.12250
3465118123597Noneitem_code26Disposal off the excess excavated earth of all types by vehicle including loading, unloading with all lead and lifts, labour, HOM of machineries etc. for:Distance of 1 to 2 kmCum82.9582.953.15FalseNoneNoneFalseNoneFalse261.29250
3465119123597Noneitem_code27Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.In all kinds of soils. Depth upto 1.50mCum508.2508.2135.0FalseNoneNoneFalseNoneFalse68607.00
3465120123597Noneitem_code28Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.90mm(weight of pipe -1.313 kg)6 Kg/m2Mtr270.9270.9400.0FalseNoneNoneFalseNoneFalse108360.00
3465121123597Noneitem_code29Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specificationsCum168.0168.0108.0FalseNoneNoneFalseNoneFalse18144.00
3465122123597Noneitem_code30Removing and restoring house connections (Labour Charges only)Each194.25194.2525.0FalseNoneNoneFalseNoneFalse4856.250
3465123123597Noneitem_code31Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6961.56961.53.15FalseNoneNoneFalseNoneFalse21928.7250
3465124123597Noneitem_code32Providing and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of Ductile Iron (DI) conforming ti IS-1865 with the latest amendments and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 with the latest amendments only. The stem sealing should be with toroidal sealing rings (minimum 2 " O " rings). Body and bonnet should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. For PN-10: (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) etc. complete For Suilce Valve of PN -10.0 and 80mmEach10912.6510912.652.0FalseNoneNoneFalseNoneFalse21825.30
3465125123597Noneitem_code33Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. etc. completeEach5552.45552.41.0FalseNoneNoneFalseNoneFalse5552.40
3465126123597Noneitem_code34Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)00 To 50.00MtrMtr388.5388.550.0FalseNoneNoneFalseNoneFalse19425.00
3465127123597Noneitem_code35Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)50.00 To 100.00Mtr DepthMtr487.2487.250.0FalseNoneNoneFalseNoneFalse24360.00
3465128123597Noneitem_code36Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)100 To150 Mtr DepthMtr517.65517.6510.0FalseNoneNoneFalseNoneFalse5176.50
3465129123597Noneitem_code37Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. 200mm6 Kg/m2(weight of pipe -6.233 kg)Mtr1015.351015.3512.0FalseNoneNoneFalseNoneFalse12184.20
3465130123597Noneitem_code38Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. 6.50 HP - 155 LPM @ 84 m = 10 STG Outlet Dia - 2.00"Each32312.732312.71.0FalseNoneNoneFalseNoneFalse32312.70
3465131123597Noneitem_code39Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x4 SqmMtr141.75141.7580.0FalseNoneNoneFalseNoneFalse11340.00
3465132123597Noneitem_code40Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 50 mmEach1312.51312.51.0FalseNoneNoneFalseNoneFalse1312.50
3465133123597Noneitem_code41Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete. 3 to 6 HP pumpsEach10027.510027.51.0FalseNoneNoneFalseNoneFalse10027.50
3465134123597Noneitem_code42Supply and delivery of galvanized mild steel tubes of 6mtr standard length heavy duty (C Class) as per IS 1239 (Part-I) 1990 with latest amendments with ISI Mark (one end fitted with Heavy Duty collar and other end fitted with protective cover) 50 mmEach3202.53202.512.0FalseNoneNoneFalseNoneFalse38430.00
3465135123597Noneitem_code43Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work.Job6825.06825.01.0FalseNoneNoneFalseNoneFalse6825.00
3465136123597Noneitem_code44Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work.Job1417.51417.51.0FalseNoneNoneFalseNoneFalse1417.50
3465137123597Noneitem_code45Labour charges for providing connection using insulated sheathed steel wire cable as per IS 1554/ 1988 with latest amendments from KPTCL pole to meter board unit, with all necessary materials ,tools and equipments,as per specificationswith testing of as per instructions of engineer incharge of work. 3 x 10 sqmm (suitable for over head mains)Mtr173.25173.2530.0FalseNoneNoneFalseNoneFalse5197.50
3465138123597Noneitem_code46Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum254.1254.12.778FalseNoneNoneFalseNoneFalse705.88980
3465139123597Noneitem_code47Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum5947.25947.20.796FalseNoneNoneFalseNoneFalse4733.97120
3465140123597Noneitem_code48Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum5891.555891.551.28FalseNoneNoneFalseNoneFalse7541.1840
3465141123597Noneitem_code49Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Basement in CM 5.6Cum6770.46770.41.536FalseNoneNoneFalseNoneFalse10399.33440
3465142123597Noneitem_code50Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6639.156639.150.796FalseNoneNoneFalseNoneFalse5284.76340
3465143123597Noneitem_code51Providing Flush / Ruled/ Struck or weathered pointing Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge.Sqm180.6180.63.6FalseNoneNoneFalseNoneFalse650.160
3465144123597Noneitem_code52Supply and erection of 2.50 mtr height ready made latrins/pumphouse/water cirsterns incluiding conveying the same carefully to work spot, loading and unloading at both destinations with all lead and lift etc complete.Each23372.023372.01.0FalseNoneNoneFalseNoneFalse23372.00
3465145123597Noneitem_code53Erection and positioning of RCC Hume pipe pump house/Cistern on size stone masory platform including transportation charges and handling,finishing with all necessary tools ,plants and materials etc.,complete as directed by the Engineer in charge of the work.Job1976.11976.11.0FalseNoneNoneFalseNoneFalse1976.10
3465146123597Noneitem_code54Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete.:Heavy Duty GI pipe of 32mm diaMtr449.4449.46.0FalseNoneNoneFalseNoneFalse2696.40
3465147123597Noneitem_code55Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS markFor 32 mm dia GM (Copper alloy) Gate valvesEach1404.91404.91.0FalseNoneNoneFalseNoneFalse1404.90
3465148123597Noneitem_code56Steel Bib CockEach186.44186.444.0FalseNoneNoneFalseNoneFalse745.760
3465149123597Noneitem_code57Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.In all kinds of soils. Depth upto 1.50mCum493.5493.525.3125FalseNoneNoneFalseNoneFalse12491.718750
3465150123597Noneitem_code58Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.90mm(weight of pipe -1.313 kg)6 Kg/m2Mtr270.9270.975.0FalseNoneNoneFalseNoneFalse20317.50
3465151123597Noneitem_code59Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specificationsCum128.1128.120.25FalseNoneNoneFalseNoneFalse2594.0250
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17202502580000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17202502580000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17202502580000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled CasteNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneValid PWD Contractor Registration CertificatePast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneTo qualify for award of this contract each tenderer in its name should have in the last five years in any one year Satisfactorily completed as prime contractor at least one any work such as of value not less than Rs.3.25 LakhsPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneValid GST Registration CertificateCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneTo qualify for award of this contract each tenderer in its name should have in the last five years i.e,2019-20 to 2023-24 achieved in at least one financial years minimum financial turnover of Rs 13.00 LakhsFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneLiquid assets and or availability of credit facilities of no less than Rs 3.90 Lakhs Credit lines/ letters of credit/ certificates from banks for meeting the fund requirement etc. (Banker Certificate is in prescribed format provided in bid document)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste reserved category as prescribed in the tender document.Othersreserved category
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- reserved category
NoneNoneNoneNoneUpload all documents as per Technical Criteria and Bid DocumentOthersTechnical Criteria and Bid Document
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Technical Criteria and Bid Document
NoneNoneNoneNoneContractors must submit the agreement with Approved Bore well agency holder with Form-7A CertificateOthersForm-7A Certificate
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Form-7A Certificate
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Upload all documents as per Technical Criteria and Bid DocumentTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone