1720419282000 | 1 | None | None | Water supply/sewage lines | Construction of 150KL MBT And Laying Of Pipe line T,Rampura ,Thondehal, Kuruvalli MVS Scheme In Kuruvalli Village In siruguppa taluk | 4811797.58 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3475234 | 124171 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 107.1 | 107.1 | 169.0 | False | None | None | False | None | False | 18099.9 | 0 | 3475235 | 124171 | None | code02 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6555.15 | 6555.15 | 7.84 | False | None | None | False | None | False | 51392.376 | 0 | 3475236 | 124171 | None | code03 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 131.63 | False | None | None | False | None | False | 36764.259 | 0 | 3475237 | 124171 | None | code04 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7028.66 | 7028.66 | 29.52 | False | None | None | False | None | False | 207486.0432 | 0 | 3475238 | 124171 | None | code05 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. for a level Upto 5 mts height | Cum | 12262.25 | 12262.25 | 8.1 | False | None | None | False | None | False | 99324.225 | 0 | 3475239 | 124171 | None | code06 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. for a levelfor a level Beyond 5 m upto 10 m | Cum | 13125.51 | 13125.51 | 8.1 | False | None | None | False | None | False | 106316.631 | 0 | 3475240 | 124171 | None | code07 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. for a levelfor a level Beyond for a level Beyond 10 m upto 15 m | Cum | 13228.51 | 13228.51 | 8.1 | False | None | None | False | None | False | 107150.931 | 0 | 3475241 | 124171 | None | code08 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. for a levelfor a level Beyond for a level Beyond 15 m upto 20 m | Cum | 13331.51 | 13331.51 | 2.27 | False | None | None | False | None | False | 30262.5277 | 0 | 3475242 | 124171 | None | code09 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. for a levelfor a level Beyond for a level Beyondfor a level Upto 5 mts height | Cum | 11771.76 | 11771.76 | 4.68 | False | None | None | False | None | False | 55091.8368 | 0 | 3475243 | 124171 | None | code10 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. for a levelfor a level Beyond for a level Beyondfor a levefor a level Beyond 5 m upto 10 m | Cum | 12301.48 | 12301.48 | 4.68 | False | None | None | False | None | False | 57570.9264 | 0 | 3475244 | 124171 | None | code11 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. for a levelfor a level Beyond for a level Beyondfor a levefor a level Beyondfor a level Beyond 10 m upto 15 m | Cum | 12389.77 | 12389.77 | 2.34 | False | None | None | False | None | False | 28992.0618 | 0 | 3475245 | 124171 | None | code12 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. for a levelfor a level Beyond for a level Beyondfor a levefor a level Beyondfor a level Beyond for a level Beyond 15 m upto 20 m | Cum | 12478.06 | 12478.06 | 7.81 | False | None | None | False | None | False | 97453.6486 | 0 | 3475246 | 124171 | None | code13 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. for a levelfor a level Beyond for a level Beyondfor a levefor a level Beyondfor a level Beyond for a level Beyond Conical wall Bottom dome 2xPxRxHxT | Cum | 13331.51 | 13331.51 | 14.39 | False | None | None | False | None | False | 191840.4289 | 0 | 3475247 | 124171 | None | code14 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. for a levelfor a level Beyond for a level Beyondfor a levefor a level Beyondfor a level Beyond for a level Beyond for a level Beyond 20 m upto 25 m | Cum | 12566.35 | 12566.35 | 20.91 | False | None | None | False | None | False | 262762.3785 | 0 | 3475248 | 124171 | None | code15 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. for a levelfor a level Beyond for a level Beyondfor a levefor a level Beyondfor a level Beyond for a level Beyond for a level BeyondTop dome 2XPxRxHxT | Cum | 13434.52 | 13434.52 | 5.86 | False | None | None | False | None | False | 78726.2872 | 0 | 3475249 | 124171 | None | code16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. for a levelfor a level Beyond for a level Beyondfor a levefor a level Beyondfor a level Beyond for a level Beyond for a level Beyond Fineal Columns | Cum | 13434.52 | 13434.52 | 0.05 | False | None | None | False | None | False | 671.726 | 0 | 3475250 | 124171 | None | code17 | Providing T.M.T steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid) including for OHT & reservoier, cost of materials, labour, HOM of machinery complete as per specifications. TMT bars Fe 500 | Tonne | 94510.5 | 94510.5 | 14.02 | False | None | None | False | None | False | 1325037.21 | 0 | 3475251 | 124171 | None | code18 | Providing and fixing RCC final and ventilators as per approved design and specifications with form works and protected with wire mesh. The plinth to be of RCC circular pillars and canopy with an ornamental finish at top. The first 22.5 cms height to be covered with RCC panelling as per detailed drawings etc.with all lead and lifts and excluding reinforcement steel. | Nos | 6732.6 | 6732.6 | 1.0 | False | None | None | False | None | False | 6732.6 | 0 | 3475252 | 124171 | None | code19 | Providing and fixing MS inspection door of size 60 cms x 60 cms, including MS frame made of 50x50x6mm angle, shutters made of 3mm thick MS sheets, with hinges, locking arrangements at top etc. including painting with anticorrosive approved paint etc. complete including all lead and lifts etc. | Nos | 2247.0 | 2247.0 | 1.0 | False | None | None | False | None | False | 2247.0 | 0 | 3475253 | 124171 | None | code20 | Providing and fixing gauge with iron sheet or enamelled guage plate of 3mm to 4mm thick, 0.23 M width with copper floats indicators and flexible nylone wires, painting figures with approved enamel paint etc.with all lead and lifts, complete for:MS Guage sheet for 2.5 m depth | Each | 6255.9 | 6255.9 | 1.0 | False | None | None | False | None | False | 6255.9 | 0 | 3475254 | 124171 | None | code21 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 93.45 | 93.45 | 608.25 | False | None | None | False | None | False | 56840.9625 | 0 | 3475255 | 124171 | None | code22 | Providing and Applying two component, water-based food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 300 of US FDA, having mixing Ratio Water) to be applied 0.35 Kg m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification | Sqm | 1756.65 | 1756.65 | 137.33 | False | None | None | False | None | False | 241240.7445 | 0 | 3475256 | 124171 | None | code23 | Providing and fixing lightening arrestor with aluminium strip 25mm x 3mm size including finial and grounding, aluminium strip to be embeded in one of the columns in and independent GI conduit of 40mm dia. pipe suitably jointed by collars with all specials with all lead and lifts etc. complete for Over Head Tanks upto 15 M staging | Nos | 14583.45 | 14583.45 | 1.0 | False | None | None | False | None | False | 14583.45 | 0 | 3475257 | 124171 | None | code24 | Providing and fixing MS ladder between landings, 45 cms wide using angle iron of specified sizes, 20mm MS bars at 25 cms. centre to centre, with necessary supports of same angle iron etc. as directed, including hand railing on both sides with 25mm dia. GI pipes with angle iron props at 2 mtrs. intervals and 0.5M heigh, including fixing in ground with CC 1:2:4 and two coats of anticorrosive bituminous paint etc. with all lead and lifts etc. complete with:MS angle of 65 x 65 x 10mm | Mtr | 5041.05 | 5041.05 | 23.0 | False | None | None | False | None | False | 115944.15 | 0 | 3475258 | 124171 | None | code25 | Ladder inside the container: Providing anodized aluminium ladder using 65mm x 32mm x 3.0mm ‘C’ section for ladder side channel x 25mm dia., flutal pipe for Rungs at 250mm c/c ladder fixed at an angle of 70 degrees to horizontal including necessary 25mm dia., G.I. shutters with necessary G.I. fasteners for bracing the ladders to the Tank walls to prevent buckling of the ladder with necessary (M-15) bed for embedding the ladder bottom complete aluminium ladder | Mtr | 5355.0 | 5355.0 | 5.0 | False | None | None | False | None | False | 26775.0 | 0 | 3475259 | 124171 | None | code26 | Providing and fixing 40mm dia. GI pipe medium duty pipes hand railing 3 rows fixed to RCC 1:2:4 vibrated post of 150x150mm at bottom and 100x150mm at top, placed at 2 Mtrs. intervals for a height of 750mm including curing, painting GI pipes with two coats of anticorrosive steel paint over a primer coat etc. with all lead lift etc. (The rate per meter is for 3 rows of GI pipes and RCC post) | Mtr | 1393.35 | 1393.35 | 92.35 | False | None | None | False | None | False | 128675.8725 | 0 | 3475260 | 124171 | None | code27 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 107.1 | 107.1 | 12.15 | False | None | None | False | None | False | 1301.265 | 0 | 3475261 | 124171 | None | code28 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 0.97 | False | None | None | False | None | False | 6099.7965 | 0 | 3475262 | 124171 | None | code29 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6789.96 | 6789.96 | 3.92 | False | None | None | False | None | False | 26616.6432 | 0 | 3475263 | 124171 | None | code30 | Providing and fixing MS inspection door of size 60 cms x 60 cms, including MS frame made of 50x50x6mm angle, shutters made of 3mm thick MS sheets, with hinges, locking arrangements at top etc. including painting with anticorrosive approved paint etc. complete including all lead and lifts etc. | No | 2247.0 | 2247.0 | 3.0 | False | None | None | False | None | False | 6741.0 | 0 | 3475264 | 124171 | None | code31 | Providing T.M.T steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid) including for OHT & reservoier, cost of materials, labour, HOM of machinery complete as per specifications. | Tonne | 82961.55 | 82961.55 | 0.294 | False | None | None | False | None | False | 24390.6957 | 0 | 3475265 | 124171 | None | code32 | Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | cm | 4.2 | 4.2 | 1500.0 | False | None | None | False | None | False | 6300.0 | 0 | 3475266 | 124171 | None | code33 | Providing and fixing board displaying information, such as 'Name of work, Tender cost, Name of Contractor, Work completion and liability period etc', having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of ize35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm ncluding, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge & MoRTH specification 804 | cm | 9450.0 | 9450.0 | 1.0 | False | None | None | False | None | False | 9450.0 | 0 | 3475267 | 124171 | None | code34 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. Consider 15% for Manual | Cum | 508.2 | 508.2 | 101.06 | False | None | None | False | None | False | 51358.692 | 0 | 3475268 | 124171 | None | code35 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata Consider 85% for Mechanical | Cum | 275.1 | 275.1 | 565.79 | False | None | None | False | None | False | 155648.829 | 0 | 3475269 | 124171 | None | code36 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata Consider Ordinary/soft rock (without requiring blasting) Depth upto 1.50 m - 10% | Cum | 476.7 | 476.7 | 56.58 | False | None | None | False | None | False | 26971.686 | 0 | 3475270 | 124171 | None | code37 | Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc - For Grade PE100 PN 10.0 110mm dia | Rmtr | 583.8 | 583.8 | 898.0 | False | None | None | False | None | False | 524252.4 | 0 | 3475271 | 124171 | None | code38 | Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc - For HDPE Grade PE100-PN10.0,160mm dia | Rmtr | 1212.75 | 1212.75 | 185.0 | False | None | None | False | None | False | 224358.75 | 0 | 3475272 | 124171 | None | code39 | Providing, Laying and Jointing Cast Iron (CI) double flanged pipes true to line / hoisting of DI flanged pipe in position and aligning to correct plumb, including cost of jointing materials, conveying to work spot with all lead and lifts etc.complete.For double flanged CI pipes of 100mm dia. For inlet pipe | Mtr | 3160.5 | 3160.5 | 24.0 | False | None | None | False | None | False | 75852.0 | 0 | 3475273 | 124171 | None | code40 | Providing, Laying and Jointing Cast Iron (CI) double flanged pipes true to line / hoisting of DI flanged pipe in position and aligning to correct plumb, including cost of jointing materials, conveying to work spot with all lead and lifts etc.complete.For double flanged For double flanged CI pipes of 150mm dia.For Outlet | Mtr | 5048.4 | 5048.4 | 21.0 | False | None | None | False | None | False | 106016.4 | 0 | 3475274 | 124171 | None | code41 | Providing, Laying and Jointing Cast Iron (CI) double flanged pipes true to line / hoisting of DI flanged pipe in position and aligning to correct plumb, including cost of jointing materials, conveying to work spot with all lead and lifts etc.complete.For double flanged CI pipes of 100mm dia. For Scour Pipe | Mtr | 3160.5 | 3160.5 | 21.0 | False | None | None | False | None | False | 66370.5 | 0 | 3475275 | 124171 | None | code42 | Providing, Laying and Jointing Cast Iron (CI) double flanged pipes true to line / hoisting of DI flanged pipe in position and aligning to correct plumb, including cost of jointing materials, conveying to work spot with all lead and lifts etc.complete.For double flanged For double flanged CI pipes of 100mm dia.For Over Flow | Mtr | 3160.5 | 3160.5 | 24.0 | False | None | None | False | None | False | 75852.0 | 0 | 3475276 | 124171 | None | code43 | Providing and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete .For DI/CI puddle flanges of100mm dia. | Each | 1954.05 | 1954.05 | 3.0 | False | None | None | False | None | False | 5862.15 | 0 | 3475277 | 124171 | None | code44 | Providing and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete .For DI/CI puddle flanges of150mm dia. | Each | 2487.45 | 2487.45 | 1.0 | False | None | None | False | None | False | 2487.45 | 0 | 3475278 | 124171 | None | code45 | Providing Ductile Iron Push on special confirming to IS 9523:2000 - All Double Socket Duck Foot DI Bends: 100 X 90 (Intlet, Overflow,Scour) | Each | 3216.15 | 3216.15 | 3.0 | False | None | None | False | None | False | 9648.45 | 0 | 3475279 | 124171 | None | code46 | Providing Ductile Iron Push on special confirming to IS 9523:2000 - All Double Socket Duck Foot DI Bends: 150 X 90 (Outlet) | Each | 5420.1 | 5420.1 | 1.0 | False | None | None | False | None | False | 5420.1 | 0 | 3475280 | 124171 | None | code47 | Providing and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of Ductile Iron (DI) conforming ti IS-1865 with the latest amendments and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 with the latest amendments only. The stem sealing should be with toroidal sealing rings (minimum 2 " O " rings). Body and bonnet should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. For PN-10: (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) etc. complete 100 mm dia (Intlet, Overflow,Scour and for future connection) | Each | 10884.0 | 10884.0 | 2.0 | False | None | None | False | None | False | 21768.0 | 0 | 3475281 | 124171 | None | code48 | Providing and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of Ductile Iron (DI) conforming ti IS-1865 with the latest amendments and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 with the latest amendments only. The stem sealing should be with toroidal sealing rings (minimum 2 " O " rings). Body and bonnet should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. For PN-10: (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) etc. complete 150 mm dia (Outlet) | Each | 17490.0 | 17490.0 | 1.0 | False | None | None | False | None | False | 17490.0 | 0 | 3475282 | 124171 | None | code49 | Labour charges for making flanged joints including cost of jointing materials comprising of rubber insertion, galvanised bolts and nuts including giving hydraulic test to the required pressure as per ISS with all lead & lift (contractor will make his own arrangement for procuring water for testing) etc. complete 100 mm dia (Intlet, Overflow,Scour ) | Nos | 218.4 | 218.4 | 23.0 | False | None | None | False | None | False | 5023.2 | 0 | 3475283 | 124171 | None | code50 | Labour charges for making flanged joints including cost of jointing materials comprising of rubber insertion, galvanised bolts and nuts including giving hydraulic test to the required pressure as per ISS with all lead & lift (contractor will make his own arrangement for procuring water for testing) etc. complete 150 mm dia (Outlet) | Nos | 325.5 | 325.5 | 7.0 | False | None | None | False | None | False | 2278.5 | 0 |
|