3477077 | 124250 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work | Cum | 417.45 | 417.45 | 63.09 | False | None | None | False | None | False | 26336.9205 | 0 |
3477078 | 124250 | None | code02 | KSRB 2.8 : Providing and Filling in foundation with granite / trap broken metal 100mm. and down size, with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift. complete as per specifications. specification. No. KBS | Cum | 3003.84 | 3003.84 | 7.69 | False | None | None | False | None | False | 23099.5296 | 0 |
3477079 | 124250 | None | code03 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical pecifications. (The cost of steel reinforcement & formwork shall be paid separately). Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6343.68 | 6343.68 | 9.01 | False | None | None | False | None | False | 57156.5568 | 0 |
3477080 | 124250 | None | code04 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7664.03 | 7664.03 | 13.56 | False | None | None | False | None | False | 103924.2468 | 0 |
3477081 | 124250 | None | code05 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesColumns | Cum | 12337.92 | 12337.92 | 0.34 | False | None | None | False | None | False | 4194.8928 | 0 |
3477082 | 124250 | None | code06 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesFor Plinth Beam | Cum | 10886.4 | 10886.4 | 2.3 | False | None | None | False | None | False | 25038.72 | 0 |
3477083 | 124250 | None | code07 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesFor Main Column | Cum | 13029.08 | 13029.08 | 2.24 | False | None | None | False | None | False | 29185.1392 | 0 |
3477084 | 124250 | None | code08 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesFoe Lintel | Cum | 12262.66 | 12262.66 | 4.88 | False | None | None | False | None | False | 59841.7808 | 0 |
3477085 | 124250 | None | code09 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesfor Slab /Chejja | Cum | 11496.24 | 11496.24 | 9.06 | False | None | None | False | None | False | 104155.9344 | 0 |
3477086 | 124250 | None | code10 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Kg | 100.2 | 100.2 | 2168.98 | False | None | None | False | None | False | 217331.796 | 0 |
3477087 | 124250 | None | code11 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6284.32 | 6284.32 | 11.55 | False | None | None | False | None | False | 72583.896 | 0 |
3477088 | 124250 | None | code12 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 297.92 | 297.92 | 17.12 | False | None | None | False | None | False | 5100.3904 | 0 |
3477089 | 124250 | None | code13 | KSRB 5.2-2 : Providing and constructing laterite size stone masonry inSuperstructure with cement mortar 1:6 (Cement 45kgs/M3) including cost and conveyance of all materials curing etc complete as per specification.I.S 3620/1979 having compressive strength not less then 3.5 N/mm2 for saturated dry samples | Cum | 7565.6 | 7565.6 | 13.95 | False | None | None | False | None | False | 105540.12 | 0 |
3477090 | 124250 | None | code14 | KSRB 7.9 : Providing and fixing M.S.grill work for windows and ventilators weighing 21kg/sqm using M.S. flats, or M.S. square rods, or combination of M.S. flats and square rods as per approved design, drawing including cutting steel sections and welding the same to required pattern with a coat of red lead primer, cost of materials, fixtures, labour and HOM of machinery complete as per specifications. Specification No. KBS 7.12 | Kg | 188.16 | 188.16 | 109.44 | False | None | None | False | None | False | 20592.2304 | 0 |
3477091 | 124250 | None | code15 | Providing Mathi / Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves ( excluding cost of cement concrete and side clamps ), but including cost of materials, labour,usage charges complete as per specifications. | Cum | 139106.24 | 139106.24 | 0.07 | False | None | None | False | None | False | 9737.4368 | 0 |
3477092 | 124250 | None | code16 | Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors, styles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and styles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour,usage charges complete as per specifications. ( excluding cost of fixtures) | Sqm | 7724.64 | 7724.64 | 1.8 | False | None | None | False | None | False | 13904.352 | 0 |
3477093 | 124250 | None | code17 | Fixing of door frame in an existing opening including embeeding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debries with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | No | 1137.92 | 1137.92 | 1.0 | False | None | None | False | None | False | 1137.92 | 0 |
3477094 | 124250 | None | code18 | Providing & fixing of 2track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm.Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P s shall not be made) | Sqm | 6036.8 | 6036.8 | 6.08 | False | None | None | False | None | False | 36703.744 | 0 |
3477095 | 124250 | None | code19 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 361.76 | 361.76 | 81.7 | False | None | None | False | None | False | 29555.792 | 0 |
3477096 | 124250 | None | code20 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 396.48 | 396.48 | 200.05 | False | None | None | False | None | False | 79315.824 | 0 |
3477097 | 124250 | None | code21 | Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). | Sqm | 1386.56 | 1386.56 | 52.97 | False | None | None | False | None | False | 73446.0832 | 0 |
3477098 | 124250 | None | code22 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. | Sqm | 995.68 | 995.68 | 2.25 | False | None | None | False | None | False | 2240.28 | 0 |
3477099 | 124250 | None | code23 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 153.44 | 153.44 | 182.9 | False | None | None | False | None | False | 28064.176 | 0 |
3477100 | 124250 | None | code24 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 176.96 | 176.96 | 106.73 | False | None | None | False | None | False | 18886.9408 | 0 |
3477101 | 124250 | None | code25 | Providing and applying painting two coats (excluding priming coat ) on new wood surface and / or wood based surface with enamel paint to give an even shade, cleaning the surface of all dirt, dust and foreign matter, sand papering including cost of materials, labour, complete as per specifications. | Sqm | 108.64 | 108.64 | 17.72 | False | None | None | False | None | False | 1925.1008 | 0 |
3477102 | 124250 | None | code26 | Sub-Estimate II Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. -32 mm dia 2.5 mm thick | m | 115.36 | 115.36 | 25.0 | False | None | None | False | None | False | 2884.0 | 0 |
3477103 | 124250 | None | code27 | Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. -32 mm dia 2.5 mm thickSupplying and fixing PVC/metal conduit Deep junction box 32 mm deep Junction box | No | 68.32 | 68.32 | 10.0 | False | None | None | False | None | False | 683.2 | 0 |
3477104 | 124250 | None | code28 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete. - 12 x 12 x 3 (300 x 300 x 76 mm) | No | 134.4 | 134.4 | 1.0 | False | None | None | False | None | False | 134.4 | 0 |
3477105 | 124250 | None | code29 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete. - 8 x 6 x 3 (203 x 152 x 76 mm) | No | 96.32 | 96.32 | 1.0 | False | None | None | False | None | False | 96.32 | 0 |
3477106 | 124250 | None | code30 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. upto 50 mm conduit in brick wall | m | 32.48 | 32.48 | 8.0 | False | None | None | False | None | False | 259.84 | 0 |
3477107 | 124250 | None | code31 | Supplying And Fixing Metal Fan Box with Round Hook. | No | 131.04 | 131.04 | 2.0 | False | None | None | False | None | False | 262.08 | 0 |
3477108 | 124250 | None | code32 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. | No | 301.28 | 301.28 | 3.0 | False | None | None | False | None | False | 903.84 | 0 |
3477109 | 124250 | None | code33 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Medium point above 3m upto 6m from tapping point to out let via switch box | No | 424.48 | 424.48 | 3.0 | False | None | None | False | None | False | 1273.44 | 0 |
3477110 | 124250 | None | code34 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Long point above 6m upto 10m from tapping point to out let via switch box | No | 621.6 | 621.6 | 3.0 | False | None | None | False | None | False | 1864.8 | 0 |
3477111 | 124250 | None | code35 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. -1.5 mm21.5Sqm | m | 29.12 | 29.12 | 15.0 | False | None | None | False | None | False | 436.8 | 0 |
3477112 | 124250 | None | code36 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. -2.5Sqm | m | 47.04 | 47.04 | 25.0 | False | None | None | False | None | False | 1176.0 | 0 |
3477113 | 124250 | None | code37 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. -4.0Sqm | m | 70.56 | 70.56 | 6.0 | False | None | None | False | None | False | 423.36 | 0 |
3477114 | 124250 | None | code38 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall- 4-5 Way4-5Ways | No | 198.24 | 198.24 | 1.0 | False | None | None | False | None | False | 198.24 | 0 |
3477115 | 124250 | None | code39 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall- 4-5 Way16-Ways | No | 406.56 | 406.56 | 1.0 | False | None | None | False | None | False | 406.56 | 0 |
3477116 | 124250 | None | code40 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box4 Module | No | 196.0 | 196.0 | 1.0 | False | None | None | False | None | False | 196.0 | 0 |
3477117 | 124250 | None | code41 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box16-Module | No | 444.64 | 444.64 | 1.0 | False | None | None | False | None | False | 444.64 | 0 |
3477118 | 124250 | None | code42 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A One Way Switch | No | 114.24 | 114.24 | 10.0 | False | None | None | False | None | False | 1142.4 | 0 |
3477119 | 124250 | None | code43 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Three Way socket | No | 191.52 | 191.52 | 2.0 | False | None | None | False | None | False | 383.04 | 0 |
3477120 | 124250 | None | code44 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Stepped Fan Regulator Two Module | No | 399.84 | 399.84 | 1.0 | False | None | None | False | None | False | 399.84 | 0 |
3477121 | 124250 | None | code45 | Supplying and fixing 32A security and energy saving DP switch with key tag suitable to operate on 230 V, 50Hz AC supply & completely wired on existing box. | No | 723.52 | 723.52 | 1.0 | False | None | None | False | None | False | 723.52 | 0 |
3477122 | 124250 | None | code46 | Extra for supplying 4 mm thick white plastic plate and covering for junction boxes of size ...... mm conduit using necessary machine screws. - 80 mm | No | 16.8 | 16.8 | 12.0 | False | None | None | False | None | False | 201.6 | 0 |
3477123 | 124250 | None | code47 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws. - 12 x 12 x 2 | No | 202.72 | 202.72 | 1.0 | False | None | None | False | None | False | 202.72 | 0 |
3477124 | 124250 | None | code48 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. - 32 A | No | 269.92 | 269.92 | 1.0 | False | None | None | False | None | False | 269.92 | 0 |
3477125 | 124250 | None | code49 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. -6-32 A SP | No | 464.8 | 464.8 | 1.0 | False | None | None | False | None | False | 464.8 | 0 |
3477126 | 124250 | None | code50 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. - 48 Sweep (1200 mm) Regular model | No | 3342.08 | 3342.08 | 2.0 | False | None | None | False | None | False | 6684.16 | 0 |
3477127 | 124250 | None | code51 | Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. - LED light fitting 1 x 4 - 36/40 W | No | 1421.28 | 1421.28 | 4.0 | False | None | None | False | None | False | 5685.12 | 0 |