createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1719471170658
version11
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee2920.00
emd200000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose26-07-2024 16:00:00
tenderQueryClose20-07-2024 17:30:00
technicalBidOpen29-07-2024 16:10:00
publishedDate08-07-2024 17:01:23
publishedByPostPWD_EE_DIV_GAD
publishedByUserKPE11642 - V N PATIL
bidValidityPeriod90
noOfCalls2
preBidMeetingDate10-07-2024 11:30:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnTrue
percentageRateTypeTextNone
contactPersonExecutive Engineer
splitEmdRequiredYnTrue
emdBankGuarantee100000.00
emdCash100000.00
bgValidityPeriod135
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08372238782
mobileNumberNone
tenderSupplierListNone
tenderSchedule
createdTs1719471170660
version14
createdDateNone
modifiedDateNone
tenderNumberPWD/2023-24/BD/WORK_INDENT6926/CALL-2
titleCONSTRUCTION OF SCHOOL BUILDING FOR KARNATAKA PUBLIC SCHOOL AT BANAHATTI VILLAGE,NARGUND TALUK,GADAG DISTRICT.
descriptionCONSTRUCTION OF SCHOOL BUILDING FOR KARNATAKA PUBLIC SCHOOL AT BANAHATTI VILLAGE,NARGUND TALUK,GADAG DISTRICT.
categoryWORKS
categoryTextWorks
ecv11677805.17
deptNamePublic Works Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location1682
locationNamePWD Division Office Gadaga
provisionalAmount14040000.0
groupOverheadTotal0.0
fileNumberPWD/NRD/BLD/KPSBAN/4202/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17194711710000NoneNoneBuildingsCONSTRUCTION OF SCHOOL BUILDING FOR KARNATAKA PUBLIC SCHOOL AT BANAHATTI VILLAGE,NARGUND TALUK,GADAG DISTRICT.GF7656237.21
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3375704118862NoneVolume 2 Page No 75 I.No 10.3Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.In cement mortar ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER1029.01029.0134.04FalseNoneNoneFalseNoneFalse137927.160
3375705118862NoneVolume 2 Page No 193 I.No 19.55Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground to the appropriate disposal area as per direction of Engineer-in-charge ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER37.037.0268.09FalseNoneNoneFalseNoneFalse9919.330
3375706118862NoneVolume 2 Page No 187 I.No 19.9.2Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineerin-charge. ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER1684.01684.055.63FalseNoneNoneFalseNoneFalse93680.920
3375707118862NoneVolume 2 Page No 188 I.No 19.12.1Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking to the appropriate disposal area as per directionof Engineerin-charge. ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER240.0240.0105.66FalseNoneNoneFalseNoneFalse25358.40
3375708118862NoneVolume 2 Page No 189 I.No 19.22.1Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-charge.For thickness of tiles 10 mm to 25 mm ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER37.037.0314.78FalseNoneNoneFalseNoneFalse11646.860
3375709118862NoneVolume 2 Page No 187 I.No 19.3Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER2426.02426.0140.64FalseNoneNoneFalseNoneFalse341192.640
3375710118862NoneVolume 2 Page No 190 I.No 19.30Dismantling tiled roofing with battens, boarding etc. complete including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER143.0143.0110.57FalseNoneNoneFalseNoneFalse15811.510
3375711118862NoneVolume 1 Page No 8 I.No 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER95.095.081.93FalseNoneNoneFalseNoneFalse7783.350
3375712118862NoneVolume 1 Page No 8 I.No 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER102.0102.0364.39FalseNoneNoneFalseNoneFalse37167.780
3375713118862NoneVolume 1 Page No 7 I.No 1.9Filling available excavated earth excluding rock in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5m ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER266.0266.0452.37FalseNoneNoneFalseNoneFalse120330.420
3375714118862NoneVolume 1 Page No 7 I.No 1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER474.0474.0131.49FalseNoneNoneFalseNoneFalse62326.260
3375715118862NoneVolume 1 Page No 11 I.No 1.23Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER2682.02682.078.82FalseNoneNoneFalseNoneFalse211395.240
3375716118862NoneVolume 1 Page No 18 I.No 2.10.aProviding and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M10 Grade ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER5866.05866.022.16FalseNoneNoneFalseNoneFalse129990.560
3375717118862NoneVolume 1 Page No 18 I.No 2.10.cProviding and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Isolated Footing ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER6219.06219.043.65FalseNoneNoneFalseNoneFalse271459.350
3375718118862NoneVolume 1 Page No 111 I.No 1.aFormwork, Centering & Scaffloding 8% For Isolated Footing ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER497.52497.5243.65FalseNoneNoneFalseNoneFalse21716.7480
3375719118862NoneVolume 1 Page No 18 I.No 2.10.cProviding and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Combined Footing ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER6219.06219.081.99FalseNoneNoneFalseNoneFalse509895.810
3375720118862NoneVolume 1 Page No 111 I.No 9Formwork, Centering & Scaffloding 3% For Combined Footing ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER186.57186.5781.9FalseNoneNoneFalseNoneFalse15280.0830
3375721118862NoneVolume 1 Page No 18 I.No 2.10.cProviding and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Curtain wall ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER6219.06219.05.8FalseNoneNoneFalseNoneFalse36070.20
3375722118862NoneVolume 1 Page No 111 I.No 9Formwork, Centering & Scaffloding 70% For Columns up to plinth ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER4353.34353.35.8FalseNoneNoneFalseNoneFalse25249.140
3375723118862NoneVolume 1 Page No 18 I.No 2.10.cProviding and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Columns ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER6219.06219.012.78FalseNoneNoneFalseNoneFalse79478.820
3375724118862NoneVolume 1 Page No 111 I.No 9Formwork, Centering & Scaffloding 70% For Columns ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER4353.34353.312.78FalseNoneNoneFalseNoneFalse55635.1740
3375725118862NoneVolume 1 Page No 18 I.No 2.10.cProviding and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Curtain wall ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER6219.06219.013.21FalseNoneNoneFalseNoneFalse82152.990
3375726118862NoneVolume 1 Page No 111 I.No 2Formwork, Centering & Scaffloding 10% For Curtain wall ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER621.9621.913.21FalseNoneNoneFalseNoneFalse8215.2990
3375727118862NoneVolume 1 Page No 18 I.No 2.10.cProviding and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Plinth beams ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER6219.06219.056.9FalseNoneNoneFalseNoneFalse353861.10
3375728118862NoneVolume 1 Page No 111 I.No 2Formwork, Centering & Scaffloding 50% For Plinth Beams ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER3109.53109.556.9FalseNoneNoneFalseNoneFalse176930.550
3375729118862NoneVolume 1 Page No 18 I.No 2.10.cProviding and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Beams ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER6219.06219.019.52FalseNoneNoneFalseNoneFalse121394.880
3375730118862NoneVolume 1 Page No 112 I.No 14Formwork, Centering & Scaffloding 60% For Beams ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER3731.43731.419.52FalseNoneNoneFalseNoneFalse72836.9280
3375731118862NoneVolume 1 Page No 18 I.No 2.10.cProviding and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Slab ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER6219.06219.047.08FalseNoneNoneFalseNoneFalse292790.520
3375732118862NoneVolume 1 Page No112 I.No 15Formwork, Centering & Scaffloding 50% For Roof Slab & Staircase ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER3109.53109.547.08FalseNoneNoneFalseNoneFalse146395.260
3375733118862NoneVolume 1 Page No18 I.No 2.10.cProviding and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Lintel ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER6219.06219.04.1FalseNoneNoneFalseNoneFalse25497.90
3375734118862NoneVolume 1 Page No 112 I.No 14Formwork, Centering & Scaffloding 60% For Lintel ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER3731.43731.44.1FalseNoneNoneFalseNoneFalse15298.740
3375735118862NoneVolume 1 Page No 18 I.No 2.10.cProviding and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Sill ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER6219.06219.02.4FalseNoneNoneFalseNoneFalse14925.60
3375736118862NoneVolume 1 Page No111 I.No 1.bFormwork, Centering & Scaffloding 3% For Sill ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER186.57186.572.4FalseNoneNoneFalseNoneFalse447.7680
3375737118862NoneVolume 1 Page No 18 I.No 2.10.cProviding and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. chejja ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER6219.06219.01.48FalseNoneNoneFalseNoneFalse9204.120
3375738118862NoneVolume 1 Page No 112 I.No 19Formwork, Centering & Scaffloding 45% For Chejja ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER2798.552798.551.48FalseNoneNoneFalseNoneFalse4141.8540
3375739118862NoneVolume 1 Page No 18 I.No 2.11.aSteel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings ---- Work should be carried out as per the direction of Engineer incharget89457.089457.023.1FalseNoneNoneFalseNoneFalse2066456.70
3375740118862NoneVolume 2 Page No 9 I.No 5.1.1Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER5611.05611.06.83FalseNoneNoneFalseNoneFalse38323.130
3375741118862NoneVolume 2 Page No 17 I.No 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- Work should be carried out as per the direction of Engineer inchargeSqm1310.01310.0286.67FalseNoneNoneFalseNoneFalse375537.70
3375742118862NoneVolume 2 Page No 17 I.No 6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- Work should be carried out as per the direction of Engineer inchargeSqm1104.01104.023.25FalseNoneNoneFalseNoneFalse25668.00
3375743118862NoneVolume2 Page No 77 I.No 11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- Work should be carried out as per the direction of Engineer inchargeSqm4242.04242.010.08FalseNoneNoneFalseNoneFalse42759.360
3375744118862NoneVolume 2 Page No 110 I.No 12.88Providing & fxing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour havingisolated drainage and reinforced with Galvanized Iron profle through-out the window frame. The outer frame having a overall size of 60mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fxing of glass shall be of size 20mm x 24mm. Windows shall be provided with 5mm plain foat glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2-2.5 mm. ---- Work should be carried out as per the direction of Engineer inchargeSqm5390.05390.036.36FalseNoneNoneFalseNoneFalse195980.40
3375745118862NoneVolume2 Page No 104 I.No 12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. ---- Work should be carried out as per the direction of Engineer inchargem318.0318.019.8FalseNoneNoneFalseNoneFalse6296.40
3375746118862NoneVolume 2 Page No 104 I.No 12.55.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges with both side prelam ---- Work should be carried out as per the direction of Engineer inchargeSqm2366.02366.06.3FalseNoneNoneFalseNoneFalse14905.80
3375747118862NoneVolume 2 Page No 110 I.No 12.88Providing & fixing of 2track x 2panel sliding door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour havingisolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having a overall size of 60mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2-2.5 mm. Maximum possible size 1819mm x 1819mm (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) ---- Work should be carried out as per the direction of Engineer inchargeSqm5390.05390.01.89FalseNoneNoneFalseNoneFalse10187.10
3375748118862NoneVolume2 Page No 41 I.No 8.1.2Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Work should be carried out as per the direction of Engineer inchargeSqm241.0241.0525.3FalseNoneNoneFalseNoneFalse126597.30
3375749118862NoneVolume 2 Page No 50 I.No 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- Work should be carried out as per the direction of Engineer inchargeSqm100.0100.0991.86FalseNoneNoneFalseNoneFalse99186.00
3375750118862NoneVolume 2 Page No41 I.No 8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Work should be carried out as per the direction of Engineer inchargeSqm279.0279.0331.73FalseNoneNoneFalseNoneFalse92552.670
3375751118862NoneVolume 2 Page No 61 I.No 9.17.2Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm ---- Work should be carried out as per the direction of Engineer inchargeSqm1175.01175.0215.12FalseNoneNoneFalseNoneFalse252766.00
3375752118862NoneVolume 2 Page No 59 I.No 9.2Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. ---- Work should be carried out as per the direction of Engineer inchargeSqm800.0800.039.42FalseNoneNoneFalseNoneFalse31536.00
3375753118862NoneVolume 2 Page No 64 I.No 9.34Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. ---- Work should be carried out as per the direction of Engineer inchargeSqm1545.01545.0141.58FalseNoneNoneFalseNoneFalse218741.10
3375754118862NoneVolume 2 Page No 60 I.No 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc.,complete. ---- Work should be carried out as per the direction of Engineer inchargeSqm889.0889.022.15FalseNoneNoneFalseNoneFalse19691.350
3375755118862NoneVolume 2 Page No 71 I.No 10.14Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. ---- Work should be carried out as per the direction of Engineer inchargeSqm1106.01106.040.82FalseNoneNoneFalseNoneFalse45146.920
3375756118862NoneVolume 2 Page No69 I.No 10.1.1Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. ---- Work should be carried out as per the direction of Engineer inchargeSqm4006.04006.010.08FalseNoneNoneFalseNoneFalse40380.480
3375757118862NoneVolume 2 Page No84 I.No 11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- Work should be carried out as per the direction of Engineer inchargeKg136.0136.0225.58FalseNoneNoneFalseNoneFalse30678.880
3375758118862NoneVolume 2 Page No 46 I.No 8.33.1Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Work should be carried out as per the direction of Engineer inchargeSqm158.0158.0991.84FalseNoneNoneFalseNoneFalse156710.720
3375759118862NoneVolume 2 Page No 46 I.No 8.30Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge ---- Work should be carried out as per the direction of Engineer inchargeSqm174.0174.0331.73FalseNoneNoneFalseNoneFalse57721.020
3375760118862NoneVolume 2 Page No 47 I.No 8.36.1Finishing with Epoxy paint (two coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Enginer-in-charge. ---- Work should be carried out as per the direction of Engineer inchargeSqm176.0176.046.44FalseNoneNoneFalseNoneFalse8173.440
3375761118862NoneVolume2 Page No 55 I.No 8.84Providing wall black boards in 12mm thick with CM 1:3 and applied with primer& two coats of acrylic emulsion black paint including fnishing etc.,complete. ---- Work should be carried out as per the direction of Engineer inchargeSqm475.0475.036.0FalseNoneNoneFalseNoneFalse17100.00
3375762118862NoneVolume 2 Page No 86 I.No 11.34BProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. ---- Work should be carried out as per the direction of Engineer inchargeKg183.0183.0763.56FalseNoneNoneFalseNoneFalse139731.480
17194711710001NoneNoneBuildingsCONSTRUCTION OF SCHOOL BUILDING FOR KARNATAKA PUBLIC SCHOOL AT BANAHATTI VILLAGE,NARGUND TALUK,GADAG DISTRICT.FF2623830.06
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3375763118863NoneVolume 1 Page No 18 I.No 2.10.cProviding and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Columns ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER6281.196281.1911.32FalseNoneNoneFalseNoneFalse71103.07080
3375764118863NoneVolume 1 Page No 111 I.No 9Formwork, Centering & Scaffloding 70% For Columns ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER4396.834396.8311.32FalseNoneNoneFalseNoneFalse49772.11560
3375765118863NoneVolume 1 Page No 18 I.No 2.10.cProviding and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Beams ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER6281.196281.1912.88FalseNoneNoneFalseNoneFalse80901.72720
3375766118863NoneVolume 1 Page No 112 I.No 14Formwork, Centering & Scaffloding 60% For Beams ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER3768.713768.7112.88FalseNoneNoneFalseNoneFalse48540.98480
3375767118863NoneVolume 1 Page No 18 I.No 2.10.cProviding and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Roof Slab ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER6281.196281.1930.02FalseNoneNoneFalseNoneFalse188561.32380
3375768118863NoneVolume 1 Page No 112 I.No 15Formwork, Centering & Scaffloding 50% For Roof Slab ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER3140.63140.630.02FalseNoneNoneFalseNoneFalse94280.8120
3375769118863NoneVolume 1 Page No 18 I.No 2.10.cProviding and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Staircase ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER6281.196281.192.66FalseNoneNoneFalseNoneFalse16707.96540
3375770118863NoneVolume 1 Page No 112 I.No 15Formwork, Centering & Scaffloding 50% For Roof Slab ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER3140.63140.62.66FalseNoneNoneFalseNoneFalse8353.9960
3375771118863NoneVolume 1 Page No 18 I.No 2.10.cProviding and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Lintel ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER6281.196281.192.53FalseNoneNoneFalseNoneFalse15891.41070
3375772118863NoneVolume 1 Page No 112 I.No 14Formwork, Centering & Scaffloding 60% For Lintel ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER3768.713768.712.53FalseNoneNoneFalseNoneFalse9534.83630
3375773118863NoneVolume 1 Page No 18 I.No 2.10.cProviding and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Sill ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER6281.196281.191.53FalseNoneNoneFalseNoneFalse9610.22070
3375774118863NoneVolume1 Page No 18 I.No 2.10.cProviding and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Chejja ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER6281.196281.190.98FalseNoneNoneFalseNoneFalse6155.56620
3375775118863NoneVolume 1 Page No 111 I.No 1bFormwork, Centering & Scaffloding 3% For Sill ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER188.44188.441.53FalseNoneNoneFalseNoneFalse288.31320
3375776118863NoneVolume 1 Page No 112 I.No 19Formwork, Centering & Scaffloding 45% For Chejja ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER2826.542826.540.98FalseNoneNoneFalseNoneFalse2770.00920
3375777118863NoneVolume 1 Page No 18 I.No 2.11.aSteel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings ---- Work should be carried out as per the direction of Engineer inchargeTonne90351.5790351.577.86FalseNoneNoneFalseNoneFalse710163.34020
3375778118863NoneVolume 2 Page No 17 I.No 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- Work should be carried out as per the direction of Engineer inchargeSqm1323.11323.1223.32FalseNoneNoneFalseNoneFalse295474.6920
3375779118863NoneVolume 2 Page No 17 I.No 6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- Work should be carried out as per the direction of Engineer inchargeSqm1115.041115.0412.15FalseNoneNoneFalseNoneFalse13547.7360
3375780118863NoneVolume 2 Page No 77 I.No 11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- Work should be carried out as per the direction of Engineer inchargeSqm4284.424284.425.04FalseNoneNoneFalseNoneFalse21593.47680
3375781118863NoneVolume 2 Page No 110 I.No 12.88Providing & fxing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour havingisolated drainage and reinforced with Galvanized Iron profle through-out the window frame. The outer frame having a overall size of 60mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fxing of glass shall be of size 20mm x 24mm. Windows shall be provided with 5mm plain foat glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2-2.5 mm. ---- Work should be carried out as per the direction of Engineer inchargeSqm5443.95443.920.52FalseNoneNoneFalseNoneFalse111708.8280
3375782118863NoneVolume 2 Page No 104 I.No 12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. ---- Work should be carried out as per the direction of Engineer inchargem321.18321.1820.05FalseNoneNoneFalseNoneFalse6439.6590
3375783118863NoneVolume 2 Page No 104 I.No 12.55.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges with both side prelam ---- Work should be carried out as per the direction of Engineer inchargeSqm2389.662389.666.82FalseNoneNoneFalseNoneFalse16297.48120
3375784118863NoneVolume 2 Page No 41 I.No 8.1.2Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charg ---- Work should be carried out as per the direction of Engineer inchargeSqm243.41243.41341.26FalseNoneNoneFalseNoneFalse83066.09660
3375785118863NoneVolume 2 Page No 50 I.No 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- Work should be carried out as per the direction of Engineer inchargeSqm101.0101.0651.56FalseNoneNoneFalseNoneFalse65807.560
3375786118863NoneVolume 2 Page No 41 I.No 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Work should be carried out as per the direction of Engineer inchargeSqm297.95297.95276.17FalseNoneNoneFalseNoneFalse82284.85150
3375787118863NoneVolume 2 Page No 61 I.No 9.17.2Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm ---- Work should be carried out as per the direction of Engineer inchargeSqm1186.751186.75111.04FalseNoneNoneFalseNoneFalse131776.720
3375788118863NoneVolume 2 Page No 64 I.No 9.34Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. ---- Work should be carried out as per the direction of Engineer inchargeSqm1560.451560.4572.79FalseNoneNoneFalseNoneFalse113585.15550
3375789118863NoneVolume 2 Page No 151 I.No 15.10Newly Constructed Bathroom/toilet/balcony/utility with Cementatius Waterproof coating - Below 300 m2: Providing and Applying CFTRI approved two component flexible polymer modified acrylic cementitious waterproofing coating with a mix ratio of (1 Liquid: 2 Powder), to the RCC surface like bathroom, toilet, balcony & utility area applied @ 1.7kg/m2 in 2 coats to achieve 1mm DFT, having Elongation at break 50% as per ASTM D 412, Tensile strength 1N/mm2 as per ASTM D 412, Adhesion strength: 0.80 N/mm2 as per ASTM D 4541, crack bridging upto 1mm as per ASTM C 836, Water penetration (5 bar pressure) as per BS EN 12390. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 45 gsm glass fibre mesh over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification. ---- Work should be carried out as per the direction of Engineer inchargeSqm370.67370.6732.57FalseNoneNoneFalseNoneFalse12072.72190
3375790118863NoneVolume 2 Page No 23 I.No 7.18Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slopecompacting, including cost of materials, labour, curing complete as per specifications. ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER2037.172037.1713.45FalseNoneNoneFalseNoneFalse27399.93650
3375791118863NoneVolume 2 Page No 60 I.No 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete ---- Work should be carried out as per the direction of Engineer inchargeSqm897.89897.8922.76FalseNoneNoneFalseNoneFalse20435.97640
3375792118863NoneVolume2 Page No 71 I.No 10.14Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. ---- Work should be carried out as per the direction of Engineer inchargeSqm1117.061117.0639.63FalseNoneNoneFalseNoneFalse44269.08780
3375793118863NoneVolume 2 Page No 84 I.No 11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- Work should be carried out as per the direction of Engineer inchargeKg137.36137.36148.36FalseNoneNoneFalseNoneFalse20378.72960
3375794118863NoneVolume 2 Page No46 I.No 8.33.1Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Work should be carried out as per the direction of Engineer inchargeSqm159.58159.58651.56FalseNoneNoneFalseNoneFalse103975.94480
3375795118863NoneVolume 2 Page No 46 I.No 8.30Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Work should be carried out as per the direction of Engineer inchargeSqm175.74175.74277.61FalseNoneNoneFalseNoneFalse48787.18140
3375796118863NoneVolume 2 Page No47 I.No 8.36.1Finishing with Epoxy paint (two coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Enginer-in-char ---- Work should be carried out as per the direction of Engineer inchargeSqm177.76177.7623.04FalseNoneNoneFalseNoneFalse4095.59040
3375797118863NoneVolume 2 Page No 55 I.No 8.84Providing wall black boards in 12mm thick with CM 1:3 and applied with primer& two coats of acrylic emulsion black paint including fnishing etc.,complete. ---- Work should be carried out as per the direction of Engineer inchargeSqm475.0475.018.0FalseNoneNoneFalseNoneFalse8550.00
3375798118863NoneVolume 2 Page No 86 I.No 11.34BProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. ---- Work should be carried out as per the direction of Engineer inchargeKg184.83184.83430.92FalseNoneNoneFalseNoneFalse79646.94360
17194711710000NoneNoneBuildingsCONSTRUCTION OF SCHOOL BUILDING FOR KARNATAKA PUBLIC SCHOOL AT BANAHATTI VILLAGE,NARGUND TALUK,GADAG DISTRICT.WS & S647756.6
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3375799118864NoneVolume 2 Page No 117 I.No 13.3.1Providing and fixing brass stop cock of approved quality :15 mm nominal bore ---- Work should be carried out as per the direction of Engineer inchargeNos299.0299.020.0FalseNoneNoneFalseNoneFalse5980.00
3375800118864NoneVolume 2 Page No 120 I.No 13.20.2Providing and fixing PTMT pillar cock of approved quality and colour. 15 mm nominal bore, 125 mm long foam flow, weighing not less than 120 gms ---- Work should be carried out as per the direction of Engineer inchargeNos314.0314.016.0FalseNoneNoneFalseNoneFalse5024.00
3375801118864NoneVolume 2 Page No 131 I.No 14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests ---- Work should be carried out as per the direction of Engineer inchargeNos4884.04884.04.0FalseNoneNoneFalseNoneFalse19536.00
3375802118864NoneVolume 2 Page No 131 I.No 14.2.1Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlleddevice (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid ---- Work should be carried out as per the direction of Engineer inchargeNos.4838.04838.01.0FalseNoneNoneFalseNoneFalse4838.00
3375803118864NoneVolume 2 Page No 131 I.No 14.4.3Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :Range of three urinal basins with 10litre white P.V.C. automatic flushing ---- Work should be carried out as per the direction of Engineer inchargeNos9455.09455.02.0FalseNoneNoneFalseNoneFalse18910.00
3375804118864NoneVolume 2 Page No 133 I.No 14.7.8White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow including operated levers ---- Work should be carried out as per the direction of Engineer inchargeNos4113.04113.014.0FalseNoneNoneFalseNoneFalse57582.00
3375805118864NoneVolume 2 Page No 133 I.No 14.8Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. ---- Work should be carried out as per the direction of Engineer inchargeNos1423.01423.014.0FalseNoneNoneFalseNoneFalse19922.00
3375806118864NoneVolume 2 Page No137 I.No 14.40.2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g ---- Work should be carried out as per the direction of Engineer inchargeEach496.0496.08.0FalseNoneNoneFalseNoneFalse3968.00
3375807118864NoneVolume 2 Page No 136 I.No 14.32.2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm ---- Work should be carried out as per the direction of Engineer inchargeNos1018.01018.014.0FalseNoneNoneFalseNoneFalse14252.00
3375808118864NoneVolume 2 Page No 122 I.No 13.31.2Providing & fixing Chorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction Engineer in Charge.Exposed on wall - 20mm nominal dia pipes ---- Work should be carried out as per the direction of Engineer inchargem242.0242.060.0FalseNoneNoneFalseNoneFalse14520.00
3375809118864NoneVolume 2 Page No 122 I.No 13.31.3Providing & fixing Chorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction Engineer in Charge.Exposed on wall - 25mm nominal dia pipes ---- Work should be carried out as per the direction of Engineer inchargem318.0318.060.0FalseNoneNoneFalseNoneFalse19080.00
3375810118864NoneVolume 2 Page No 122 I.No 13.31.4Providing & fixing Chorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction Engineer in Charge.Exposed on wall - 32mm nominal dia pipes ---- Work should be carried out as per the direction of Engineer inchargem400.0400.060.0FalseNoneNoneFalseNoneFalse24000.00
3375811118864NoneVolume 2 Page No 122 I.No 13.31.6Providing & fixing Chorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction Engineer in Charge.Exposed on wall - 50mm nominal dia pipes ---- Work should be carried out as per the direction of Engineer inchargem781.0781.0135.0FalseNoneNoneFalseNoneFalse105435.00
3375812118864NoneVolume 2 Page No 117 I.No 13.4.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :50 mm nominal bore ---- Work should be carried out as per the direction of Engineer inchargeNos855.0855.045.0FalseNoneNoneFalseNoneFalse38475.00
3375813118864NoneVolume 2 Page No 118 I.No 13.8.2.2Providing and fixing unplasticised PVC connection pipe with brass unions :45 cm length 20 mm nominal bore ---- Work should be carried out as per the direction of Engineer inchargeNos.110.0110.045.0FalseNoneNoneFalseNoneFalse4950.00
3375814118864NoneVolume 2 Page No 123 I.No 13.34Providing and placing on terrace, polyethylene water storage tanks as per IS 12701 : 1996 with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes but without fittings and the base support for tank ---- Work should be carried out as per the direction of Engineer inchargeLtr9.09.05000.0FalseNoneNoneFalseNoneFalse45000.00
3375815118864NoneVolume 5 Page No A-44 I.No 660PVC pipes of 8 Kg/cm2 for 140mm(3.097) ---- Work should be carried out as per the direction of Engineer inchargem456.0456.0150.4FalseNoneNoneFalseNoneFalse68582.40
3375816118864NoneVolume 5 Page No A-44 I.No 664PVC pipes of 10 Kg/cm2 for 200mm ---- Work should be carried out as per the direction of Engineer inchargem1155.01155.060.0FalseNoneNoneFalseNoneFalse69300.00
3375817118864NoneVolume 2 Page No 125 I.No 13Providing and fixing on wall face unplasticised Rigid PVC rain water pipes of 150mm dia conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes ---- Work should be carried out as per the direction of Engineer inchargem568.0568.030.4FalseNoneNoneFalseNoneFalse17267.20
3375818118864NoneVolume 5 Page No 208 I.No 61.60.1Providing PVC-U INDIVIDUAL U.G.D House service connection (which shall be laid from inside the customer property ) which includes: a) Supply of PVC-U pipe (b) providing and fixing of 315 mm dia the PE Inspection chambres with lid consisting of inlet & outlet arrangements with base, riser of min. 0.42 m depth which includes earth work, fixing in CC-1:2:4 with appurtenances., complete. (c) civil works like Earthwork excavation for the pipeline trenches for laying of PVC-U pipes for the house connections in all types of soils , disintegrated rock,soft rock, hard rock, including cutting of any road using , crossing drains, compound, Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, c.c. wood work, steel work, including T & P and scaffolding wherever necessary sorting the dismantled material, disposal of unserviceable and stacking the serviceable material with all lifts and lead , restoring the damaged portions inside or outside the property premises, refilling the portions of trenches that are dug open including linking to existing sewer network with appurtenances. complete. 110 mm dia ---- Work should be carried out as per the direction of Engineer inchargeNos8134.08134.02.0FalseNoneNoneFalseNoneFalse16268.00
3375819118864NoneVolume 5 Page No 192 I.No 16.15.1Providing and constructing “WIRE CUT BRICK MACHINEHOLE CHAMBERS” using Portland/Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber. Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Supplying and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Supplying and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, dewatering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm diaCirc. B M.HConstructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.0 M depth & SFRC cover & frame ---- Work should be carried out as per the direction of Engineer inchargeNos29047.029047.01.0FalseNoneNoneFalseNoneFalse29047.00
3375820118864NoneVolume 2 Page No 136 I.No 14.29Providing and fixing 100 mm sand cast Iron grating for gully trap. ---- Work should be carried out as per the direction of Engineer inchargeNos47.047.020.0FalseNoneNoneFalseNoneFalse940.00
3375821118864NoneVolume2 Page No 120 I.No 13.22.1.2Providing and fixing PTMT grating of approved quality and colour 125 mm nominal dia ---- Work should be carried out as per the direction of Engineer inchargeNos44.044.020.0FalseNoneNoneFalseNoneFalse880.00
3375822118864NoneVolume 5(WS&UGD) Page No 247 I.No 21.1.2.3Water purification plants: Supplying, Installation and Commissioning of automatic Water purification plant (RO+UF) with all accessories piping, product water tank on single phase power supply as per the enclosed detailed Technical Specifications including cost of material, loading and unloading and as directed by the Engineer in charge. (Ref- detailedspecification enclosed seperatly). Note:- 1.The above rates mentioned are only for the preparation of estimate purpose. 2. All items are to be of BSI /NFS standards,with BSI / NFS mark . 3. Tenders to be invited for procurement. 4. No direct payment should be made under any situation or condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge. Note : Refer the ANNEXURE : F for Detailed Specification of Each components For 50 LPH : Cabin Type ---- Work should be carried out as per the direction of Engineer inchargeEach44000.044000.01.0FalseNoneNoneFalseNoneFalse44000.00
17194711710000NoneNoneBuildingsCONSTRUCTION OF SCHOOL BUILDING FOR KARNATAKA PUBLIC SCHOOL AT BANAHATTI VILLAGE,NARGUND TALUK,GADAG DISTRICT. ELE749981.3
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3375823118865NoneVolume 6 I.No 1.2.1Supplying heavy gauge PVC conduit pipe mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary19/20 mm dia 2 mm thick ---- Work should be carried out as per the direction of Engineer inchargem66.066.0240.0FalseNoneNoneFalseNoneFalse15840.00
3375824118865NoneVolume 6 I.No 1.2.2Supplying heavy gauge PVC conduit pipe mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thick ---- Work should be carried out as per the direction of Engineer inchargem78.078.0180.0FalseNoneNoneFalseNoneFalse14040.00
3375825118865NoneVolume 6 I.No1.5.1Supplying and fixing PVC/metal conduit Deep junction box19/20 mm deep Junction box ---- Work should be carried out as per the direction of Engineer inchargeEach49.049.0190.0FalseNoneNoneFalseNoneFalse9310.00
3375826118865NoneVolume 6 I.No 1.5.2Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction box ---- Work should be carried out as per the direction of Engineer inchargeEach56.056.090.0FalseNoneNoneFalseNoneFalse5040.00
3375827118865NoneVolume 6 I.No 1.3.1Supplying heavy gauge PVC Conduit Pipe . dia mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.19/20 mm dia 2 mm thic ---- Work should be carried out as per the direction of Engineer inchargem68.068.0180.0FalseNoneNoneFalseNoneFalse12240.00
3375828118865NoneVolume 6 I.No 1.3.2Supplying heavy gauge PVC Conduit Pipe . dia mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25 mm dia 2 mm thick ---- Work should be carried out as per the direction of Engineer inchargem79.079.0120.0FalseNoneNoneFalseNoneFalse9480.00
3375829118865NoneVolume 6 I.No1.12Supplying And Fixing Metal Fan Box with Round Hook. ---- Work should be carried out as per the direction of Engineer inchargeNo160.0160.040.0FalseNoneNoneFalseNoneFalse6400.00
3375830118865NoneVolume 6 I.No 2.2.1Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3m from tapping point to out let via switch box ---- Work should be carried out as per the direction of Engineer inchargePoint269.0269.0120.0FalseNoneNoneFalseNoneFalse32280.00
3375831118865NoneVolume 6 I.No 2.2.2Point wiring using Copper wire without switchSupplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Medium point above 3m upto 6m from tapping point to out let via switch box ---- Work should be carried out as per the direction of Engineer inchargePoint379.0379.060.0FalseNoneNoneFalseNoneFalse22740.00
3375832118865NoneVolume 6 I.No 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall1-3 Way ---- Work should be carried out as per the direction of Engineer inchargeEach138.0138.060.0FalseNoneNoneFalseNoneFalse8280.00
3375833118865NoneVolume6 I.No 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ---- Work should be carried out as per the direction of Engineer inchargeEach177.0177.030.0FalseNoneNoneFalseNoneFalse5310.00
3375834118865NoneVolume 6 I.No 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6 Way ---- Work should be carried out as per the direction of Engineer inchargeEach220.0220.012.0FalseNoneNoneFalseNoneFalse2640.00
3375835118865NoneVolume 6 I.No 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ---- Work should be carried out as per the direction of Engineer inchargeEach261.0261.012.0FalseNoneNoneFalseNoneFalse3132.00
3375836118865NoneVolume 6 I.No 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.3 Module ---- Work should be carried out as per the direction of Engineer inchargeEach161.0161.012.0FalseNoneNoneFalseNoneFalse1932.00
3375837118865NoneVolume 6 I.No 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.4 Module ---- Work should be carried out as per the direction of Engineer inchargeEach175.0175.020.0FalseNoneNoneFalseNoneFalse3500.00
3375838118865NoneVolume6 I.No 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.6 Module ---- Work should be carried out as per the direction of Engineer inchargeEach234.0234.012.0FalseNoneNoneFalseNoneFalse2808.00
3375839118865NoneVolume 6 I.No3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.8 Module ---- Work should be carried out as per the direction of Engineer inchargeEach284.0284.020.0FalseNoneNoneFalseNoneFalse5680.00
3375840118865NoneVolume 6 I.No 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A One Way Switch ---- Work should be carried out as per the direction of Engineer inchargeEach102.0102.0120.0FalseNoneNoneFalseNoneFalse12240.00
3375841118865NoneVolume 6 I.No3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Two Way Switch ---- Work should be carried out as per the direction of Engineer inchargeEach166.0166.08.0FalseNoneNoneFalseNoneFalse1328.00
3375842118865NoneVolume 6 I.No 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Three Way socket ---- Work should be carried out as per the direction of Engineer inchargeEach171.0171.040.0FalseNoneNoneFalseNoneFalse6840.00
3375843118865NoneVolume 6 I.No 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Stepped Fan Regulator Two Module ---- Work should be carried out as per the direction of Engineer inchargeEach357.0357.040.0FalseNoneNoneFalseNoneFalse14280.00
3375844118865NoneVolume 6 I.No 3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Bell Push ---- Work should be carried out as per the direction of Engineer inchargeEach177.0177.04.0FalseNoneNoneFalseNoneFalse708.00
3375845118865NoneVolume 6 I.No3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.32A DP Switch ---- Work should be carried out as per the direction of Engineer inchargeEach326.0326.016.0FalseNoneNoneFalseNoneFalse5216.00
3375846118865NoneVolume 6 I.No 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6/16A Universal Socket ---- Work should be carried out as per the direction of Engineer inchargeEach236.0236.016.0FalseNoneNoneFalseNoneFalse3776.00
3375847118865NoneVolume 6 I.No 3.10.2Extra for supplying 4 mm thick white plastic plate and covering for junction boxes of size . mm conduit using necessary machine screws.80 mm ---- Work should be carried out as per the direction of Engineer inchargeNo15.015.080.0FalseNoneNoneFalseNoneFalse1200.00
3375848118865NoneVolume 6 I.No 3.10.3Extra for supplying 4 mm thick white plastic plate and covering for junction boxes of size . mm conduit using necessary machine screws.110 mm ---- Work should be carried out as per the direction of Engineer inchargeNo21.021.070.0FalseNoneNoneFalseNoneFalse1470.00
3375849118865NoneVolume6 I.No 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.1.5 mm2 ---- Work should be carried out as per the direction of Engineer inchargem26.026.0400.0FalseNoneNoneFalseNoneFalse10400.00
3375850118865NoneVolume 6 I.No2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.5 mm2 ---- Work should be carried out as per the direction of Engineer inchargem42.042.0400.0FalseNoneNoneFalseNoneFalse16800.00
3375851118865NoneVolume 6 I.No 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.4 mm2 ---- Work should be carried out as per the direction of Engineer inchargem63.063.0300.0FalseNoneNoneFalseNoneFalse18900.00
3375852118865NoneVolume 6 I.No 2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.6 mm2 ---- Work should be carried out as per the direction of Engineer inchargem92.092.0300.0FalseNoneNoneFalseNoneFalse27600.00
3375853118865NoneVolume6 I.No5.7.4Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.100 A ---- Work should be carried out as per the direction of Engineer inchargeEach691.0691.08.0FalseNoneNoneFalseNoneFalse5528.00
3375854118865NoneVolume 6 I.No 5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SP ---- Work should be carried out as per the direction of Engineer inchargeEach415.0415.012.0FalseNoneNoneFalseNoneFalse4980.00
3375855118865NoneVolume 6 I.No 5.18.4Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A DP ---- Work should be carried out as per the direction of Engineer inchargeEach739.0739.012.0FalseNoneNoneFalseNoneFalse8868.00
3375856118865NoneVolume 6 I.No 5.18.6Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.50-63 Amps DP ---- Work should be carried out as per the direction of Engineer inchargeEach1102.01102.010.0FalseNoneNoneFalseNoneFalse11020.00
3375857118865NoneVolume 6 I.No 5.18.7Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32Amps TPN ---- Work should be carried out as per the direction of Engineer inchargeEach1717.01717.04.0FalseNoneNoneFalseNoneFalse6868.00
3375858118865NoneVolume 6 I.No 5.19.7Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.II - Double Door6 Way SP & N ---- Work should be carried out as per the direction of Engineer inchargeEach1791.01791.04.0FalseNoneNoneFalseNoneFalse7164.00
3375859118865NoneVolume 6 I.No 5.19.13Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.III - Double Door8 Way TP & N ---- Work should be carried out as per the direction of Engineer inchargeEach6091.06091.04.0FalseNoneNoneFalseNoneFalse24364.00
3375860118865NoneVolume 6 I.No5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR Pole100 A 25 kA ---- Work should be carried out as per the direction of Engineer inchargeEach8487.08487.01.0FalseNoneNoneFalseNoneFalse8487.00
3375861118865NoneVolume 6 I.No5.15.11Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR Pole160 A 25 kA ---- Work should be carried out as per the direction of Engineer inchargeEach13447.013447.01.0FalseNoneNoneFalseNoneFalse13447.00
3375862118865NoneVolume6 I.No 5.20.1Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board.16-25 A 2 pole ---- Work should be carried out as per the direction of Engineer inchargeEach4277.04277.04.0FalseNoneNoneFalseNoneFalse17108.00
3375863118865NoneVolume 6 I.No 5.20.10Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board.63 A 4 pole ---- Work should be carried out as per the direction of Engineer inchargeEach5545.05545.04.0FalseNoneNoneFalseNoneFalse22180.00
3375864118865NoneVolume 6 I.No 5.12.1Supplying of on load change over switches 4 poles, AC 23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution) 63 A ---- Work should be carried out as per the direction of Engineer inchargeEach6881.06881.01.0FalseNoneNoneFalseNoneFalse6881.00
3375865118865NoneVolume 6 I.No 6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.48" Sweep (1200 mm) Regular model ---- Work should be carried out as per the direction of Engineer inchargeEach2984.02984.032.0FalseNoneNoneFalseNoneFalse95488.00
3375866118865NoneVolume 6 I.No 13.11Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clA and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. ---- Work should be carried out as per the direction of Engineer inchargeEach315.0315.032.0FalseNoneNoneFalseNoneFalse10080.00
3375867118865NoneVolume 6 I.No 13.12Extra length of GI pipe of class B 19mm dia for down rod. ---- Work should be carried out as per the direction of Engineer inchargeEach197.0197.032.0FalseNoneNoneFalseNoneFalse6304.00
3375868118865NoneVolume 6 I.No 11.3.1Supplying of .feet -PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 2 - 9/10 W ---- Work should be carried out as per the direction of Engineer inchargeEach551.0551.020.0FalseNoneNoneFalseNoneFalse11020.00
3375869118865NoneVolume 6 I.No 11.3.2Supplying of .feet -PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4 - 20/22 W ---- Work should be carried out as per the direction of Engineer inchargeEach690.0690.020.0FalseNoneNoneFalseNoneFalse13800.00
3375870118865NoneVolume 6 I.No 3.14.6Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board.6A Lamp Holder ---- Work should be carried out as per the direction of Engineer inchargeNo71.071.030.0FalseNoneNoneFalseNoneFalse2130.00
3375871118865NoneVolume6 I.No11.11.7Supplying & fixing of retrofit type - LED bulb . W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage. short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.18W,6500K ---- Work should be carried out as per the direction of Engineer inchargeEach426.0426.04.0FalseNoneNoneFalseNoneFalse1704.00
3375872118865NoneVolume 6 I.No 11.4.3Supplying of recess mounting non integrated type LED down light. W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clA, LED of Power/COB with CCT 6500 degree K, CRI70%. efficacy 100 lumen per W, 120degree beam spread, life25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.15-18W ---- Work should be carried out as per the direction of Engineer inchargeEach1671.01671.040.0FalseNoneNoneFalseNoneFalse66840.00
3375873118865NoneVolume 6 I.No13.7.1Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.On wall/ ceiling / Rafter / Girders ---- Work should be carried out as per the direction of Engineer inchargeEach122.0122.0116.0FalseNoneNoneFalseNoneFalse14152.00
3375874118865NoneVolume 6 I.No 11.8.4Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defectLED Streetlight 90 W ---- Work should be carried out as per the direction of Engineer inchargeNo8860.08860.02.0FalseNoneNoneFalseNoneFalse17720.00
3375875118865NoneVolume 6 I.No 13.2.1Supplying and Fixing.mm dia class A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clA, bolts, nuts and wiring using suitable capacity wires.Using 25mm dia G.I.Pipe ---- Work should be carried out as per the direction of Engineer inchargeEach1203.01203.02.0FalseNoneNoneFalseNoneFalse2406.00
3375876118865NoneVolume 6 I.No 5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. ---- Work should be carried out as per the direction of Engineer inchargeEach9255.09255.01.0FalseNoneNoneFalseNoneFalse9255.00
3375877118865NoneVolume 6 I.No 5.29Supplying, fixing and wiring 3 Phase Digital Ammeter /Voltmeter ---- Work should be carried out as per the direction of Engineer inchargeEach1425.01425.01.0FalseNoneNoneFalseNoneFalse1425.00
3375878118865NoneVolume 6 I.No 5.34Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound. ---- Work should be carried out as per the direction of Engineer inchargeEach562.0562.01.0FalseNoneNoneFalseNoneFalse562.00
3375879118865NoneVolume 6 I.No5.35Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 A three phase 4 wire whole current class-1 Accuracy Energy Meter. ---- Work should be carried out as per the direction of Engineer inchargeEach5705.05705.01.0FalseNoneNoneFalseNoneFalse5705.00
3375880118865NoneVolume 6I.No5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. ---- Work should be carried out as per the direction of Engineer inchargeEach515.0515.03.0FalseNoneNoneFalseNoneFalse1545.00
3375881118865NoneVolume 6 I.No 5.40.1Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete100 A 4 x 30 x 6 mm Aluminium Strips ---- Work should be carried out as per the direction of Engineer inchargem2465.02465.01.8FalseNoneNoneFalseNoneFalse4437.00
3375882118865NoneVolume 6 I.No 5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.16 SWG ---- Work should be carried out as per the direction of Engineer inchargeSq CM0.430.4318000.0FalseNoneNoneFalseNoneFalse7740.00
3375883118865NoneVolume6 I.No 32.111.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-397550 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm) ---- Work should be carried out as per the direction of Engineer inchargeKm178973.0178973.00.1FalseNoneNoneFalseNoneFalse17897.30
3375884118865NoneVolume 1 I.No 1.17.1Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. All kinds of soils. Depth upto 1.50 mIn Ordinary Soil ---- Work should be carried out as per the direction of Engineer inchargeCUBIC METER262.0262.060.0FalseNoneNoneFalseNoneFalse15720.00
3375885118865NoneVolume 6 I.No 5.41.1Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. Flat.with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.40 x 40 x 6 mm ---- Work should be carried out as per the direction of Engineer inchargem305.0305.06.0FalseNoneNoneFalseNoneFalse1830.00
3375886118865NoneVolume6 I.No 5.41.2Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. Flat.with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.50 x 50 x 6 mm ---- Work should be carried out as per the direction of Engineer inchargem395.0395.06.0FalseNoneNoneFalseNoneFalse2370.00
3375887118865NoneVolume6 I.No6.1Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- Work should be carried out as per the direction of Engineer inchargeEach1492.01492.04.0FalseNoneNoneFalseNoneFalse5968.00
3375888118865NoneVolume 6 I.No13.13Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- Work should be carried out as per the direction of Engineer inchargeEach707.0707.04.0FalseNoneNoneFalseNoneFalse2828.00
3375889118865NoneVolume 6 I.No 51.04Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified ---- Work should be carried out as per the direction of Engineer inchargeNo2172.02172.04.0FalseNoneNoneFalseNoneFalse8688.00
3375890118865NoneVolume 6 I.No 15.05Bentonite clay slurry for earthing in 50 Kg Bag ---- Work should be carried out as per the direction of Engineer inchargeBag368.0368.03.0FalseNoneNoneFalseNoneFalse1104.00
3375891118865NoneVolume 6 I.No 15.02Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each ---- Work should be carried out as per the direction of Engineer inchargeNo676.0676.03.0FalseNoneNoneFalseNoneFalse2028.00
3375892118865NoneVolume 6 I.No 15.03Good Quality Salt for grounding purposes packed in 50 Kg gunny bag ---- Work should be carried out as per the direction of Engineer inchargeBag310.0310.03.0FalseNoneNoneFalseNoneFalse930.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17194711710000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17194711710000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17194711710000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of kppp on or before the last date and time of bid submission.None
17194711710000NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of kppp portal due to internet connectivity issues and technical glitches at bidders endNone
17194711710000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidder.None
17194711710000NoneNoneELIGIBILITYTender invited only for eligible contractors registered under Karnataka Public Works DeptNone
17194711710000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17194711710000NoneNoneELIGIBILITYThe Tenderer shall obtain the workdone certificate in the prescribed format from the Competent Authority not below the rank of Executive Engineer(District Level Officer)and scan the Original Certificate and attach the scanned file to the Bid.None
17194711710000NoneNoneELIGIBILITYFinancial Year will be reckoned as the period between first day of April and Thiry first day of March of succeeding year(both days inclusive)None
17194711710000NoneNoneELIGIBILITYThe Tenderer shall scan the Original Ownership Documents/ Lease/ Hire committement Agreement for the Machinery and attach the scanned file to the Bid. The Original Documents shall be produced at the time of opening of technical Bids for physical verification.None
17194711710000NoneNoneELIGIBILITYThe tenderer shall note that the scanned Documents can also be uploaded in the tasks created under Document/Evidence Required from the BidderNone
17194711710000NoneNoneELIGIBILITYThe Employer reserves the right to Reject any or all Tenders without assigning any reasonNone
17194711710000NoneNoneELIGIBILITYThe Department is not responsible for any delay in accessing kpp portalNone
17194711710000NoneNoneELIGIBILITYTenderer shall note that the Tenders of those found Eligible as mentioned in Clause 3 - Qualification of the Tenderer in Section 2 : Instructions to Tenderers (ITT), will only be considered for evaluation.None
17194711710000NoneNoneELIGIBILITYAll materials required for the work shall be procured by the tenderer himself and should be got tested by the quality control authorities at his own cost before use on work.None
17194711710000NoneNoneELIGIBILITYThe items quoted shall include cost of Royalty charges on constructive materials and other taxes as per the rates prevailing Govt Orders at the time of execution and including all the cost and conveyance of all materials, curing, loading and unloading with all lead and lifts, labour, hire charges of machinary and equipments, etc., complete and all incidental charges. All the items shall be executed as directed by the Engineer in charge of the work.None
17194711710000NoneNoneELIGIBILITYPhysical quantities requirement to qualify the Tenderer is 80% of the estimated quantity as per Govt Order No. .PW/630/CRM/2014 Bangalore Dated: 17-11-2014None
17194711710000NoneNoneELIGIBILITYDepartment will not supply any materials.None
17194711710000NoneNoneELIGIBILITYThe cost of the Tender form shall not be refundable.None
17194711710000NoneNoneELIGIBILITYFurther particulars, if any, required by the Contractor can be had from the office of the Executive Engineer, PWD Division Gadag during office hours on all working days. It may be noted that if any of the dates mentioned above happened next working day will holds good in lieu of the dates mentioned.None
17194711710000NoneNoneELIGIBILITYEpayment Challan should be ScannedNone
17194711710000NoneNoneELIGIBILITYThe Tenderer must be present during opening of tender and submit uploaded documents duly attested by Gazzeted Officer not below the rank of Executive Engineer and also produce original documents for confirmation at the time of opening.None
17194711710000NoneNoneELIGIBILITYAs per Karnataka State Govt Order No:LD/300/LET/2006/Bangalore Dt: 1-1-2007 and Govt Ltr No:PW/134/BMS/2007, Dt: 27-7-2007, a sum amounting to 1% of the bill amount will be deducted towards Construction Labour Welfare fund.None
17194711710000NoneNoneELIGIBILITYTHE CONTRACTORS ARE INSTRUCTED TO SUBMIT ONLY RELEVENT INFORMATION WITH RECORDS AS REQUIRED AND SPECIFIED IN QUALIFICATION CRITERIA.ANY JUNK ,SURPLUS AND UNNECESARY DOCUMENTS IF UPLOADED WILL TREATED AS MISLEADING AND SUCH TENDERS ARE LIABLE TO BE REJECTION.None
17194711710000NoneNoneELIGIBILITYFinancial turnover of previous years shall be given a weight of 10% per year to bring them to the price level of the 2023-24 in the Technical Qualification Criteria mentioned in the next sectionNone
17194711710000NoneNoneELIGIBILITYThe item rates are excluding GST but inclusive of all other charges.None
17194711710000NoneNoneELIGIBILITYGST shall be paid to the tendered amount separately.None
17194711710000NoneNoneELIGIBILITYThe Increase in GST shall not be paid in the extended period of contract for which the contractor alone is responsible for delays as determined by the authority while granting the extension of time.None
17194711710000NoneNoneELIGIBILITYThe Item Rate quoted shall include the Royalty Charges on construction materials and other taxes (excluding GST) as per prevailing Government OrdersNone
17194711710000NoneNoneELIGIBILITYWork Completion/Execution Period : 11 MonthsNone
17194711710000NoneNoneELIGIBILITYThe Project Completion period is 11 months and the Tenderer should maintain work during the defect liability period, which is (1) one year after successful completion of the work.None
17194711710000NoneNoneELIGIBILITYStar rates are applicable, As per the Government Circular No. PWD 159 CRM 2009 Bangalore dated 30-9-2010None
17194711710000NoneNoneELIGIBILITYBidder Should Carry out the Electrical works As per instruction of Site Eng of PWD and HESCOM . The bidder Should get the necessary approvals required for execution of electrical works from HESCOM dept & electrical inspector. Any necessary deposits & supervision charges will be borne by the department, if paid by the bidder it will be reimbursed.None
17194711710000NoneNoneELIGIBILITYAll necessary arrangements shall be made and precaution taken to prevent completely or partially, damage to the structure or labours / employees during construction period. (As per recent Labour Act) Contractor shall be fully responsible for any damage to the structure during the construction and maintenance period.Any damage caused due to any reasons shall be rectified / replaced at his own cost as per the direction of Engineer in charge. Nothing shall be payable by the Department on account of inclusive of all such arrangements/ precautions work needed.None
17194871570000NoneNoneELIGIBILITYLOC should be preescribed formate-2, If not then the tender will not be acceptedNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneTo qualify for award of this contract, each Tenderer in its name should have in the last five years i.e.,2019-20,2020-21,2021-22,2022-23 and 2023-24 Satisfactorily completed as prime contractor, at least one similar work such as Construction of Building Works of value not less then Rs 58.39 lakhsPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work1)Earthwork-872.14 Cum 2)Concrete work (Including PCC/RCC)-297.61 Cum 3)Steel-24.77 Tonne 4)Solid concrete blocks/BBM/UCR/SSM-89.89 Cum 5)Plastering-685.62 Sqm 6) Flooring-343.80 SqmPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Quantity wise work done certificate
NoneNoneNoneNoneList of existing commitments and ongoing worksPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- List of existing commitments and ongoing works
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- on letter head
NoneNoneNoneNoneTenderers who meet the above specified minimum qualifying criteria, will only be qualified,if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under Assessed available tender capacity-( AxNx1.5-B )whereA-Maximum value of civil engineering works executed in any one year during the last five years (updated to 2024-25 price level) taking into account the completed as well as works in progress.N -Number of years prescribed for completion of the works for which tenders are invited -0.916 Year.B-Value at 2024-25 price level, of existing commitments and on-going works to be completed during the next 0.916 year (Period of completion of the works for which tenders are invited)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Calculation sheet on letter head
NoneNoneNoneNoneAssessed Tender Capacity shall be more than the Tendered AmountCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Assessment on the Letter Head of the Tenderer
NoneNoneNoneNone3.3 a Each Tenderer should further demonstrate :As per this note, each tenderer should demonstrate availability of few key equipments /machinery for execution of the work . However as per Govt circular no GO-FD/AE 263/EXP12-2022 dt-11-05-2022, this clause for owning key equipments for works costing up to Rs.3.00 crores is exempted. However it is obligatory for the contractor to use the following machineries for various activities involved in construction as per Morth specification.Sl No. Name of machinery 1)Excavator JCB / Hitachi 2)Tippers3)Concrete Batching Plant4)Water Tanker5)Shuttering Materials6)Transit Mixers7)Selfloading Moblie Concrete Batching Plant of min 2 cum capacityCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- list of machinery
NoneNoneNoneNoneTo qualify for award of this contract, each Tenderer in its name should have in the last five years i.e.,2019-20,2020-21,2021-22,2022-23 and 2023-24, (a) acheived in at least two financial years a minimum financial turnover of Rs. 233.55 lakhs (in all classes of civil engineering construction works only) 33.( As per GOVT Circuler No PW 60 CRM 2021 Bangaluru Dtd-08-11-2021)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneMaximum of Civil Engineering works executed in any one year during the last five years (updated to 2024-25 price level) taking into account the completed as well as works in progress. (Financial turnover of previous years shall be given a weight of 10% per year to bring them to the price level of the 2024-25)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Statement on the Letter head of the tenderer
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. 31.85 Lakhs (estimated cash flow for 3 months of peak construction period)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneThe EMD of Rs.2,00,000 shall be paid in full through e-payment or in two parts i.e,Part(1)Rs. 1,00,000.00 by e-payment part (2)1,00,000 in the form of BG to be upload.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- EMD Details
NoneNoneNoneNoneValue at 2024-25 price level, of existing commitments and on-going works to be executed during the next 12 months(Financial commitment of previous years shall be given a weight of 10% per year to bring them to the price level of the 2024-25), (Monthwise commitment shall be furnished).Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Statement on the Letter head of the tenderer
NoneNoneNoneNoneBanker Details for referenceOthersBanker Details for reference
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Banker Details for reference
NoneNoneNoneNoneInformation on litigation in which the Tender is involved.OthersInformation on litigation in which the Tender is involved.
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Information on litigation in which the Tender is involved.
NoneNoneNoneNoneInformation of the works for which Tender acceptance letters are received.OthersInformation of the works for which Tender acceptance letters are received.
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- New work
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Contractors PWD Registration CertificateTrueTechnical Bid
Quantity wise workdone certificateTrueTechnical Bid
Existing commitments & ongoing works listTrueTechnical Bid
LOC should be preescribed formate-2, If not then the tender will not be acceptedTrueTechnical Bid
Bid Capacity on Contractor Letter HeadTrueTechnical Bid
Similar Nature of workdone certificateTrueTechnical Bid
Other related documentsTrueTechnical Bid
Personal detailsTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1719833265000
version0
createdDateNone
modifiedDateNone
blockNumberExecutive engineer office pwd division Gadag
streetNone
cityGadag
stateKarnataka
pin582101
tenderRecallDTONone