1720523219000 | 0 | None | None | Buildings | GROUND FLOOR(CIVIL WORKS) | 20764505.08 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3497218 | 124918 | None | V-3 P.No 7 It.No 2.5A | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer In area of light jungle
| Sqm | 486.93 | 486.93 | 6.94 | False | None | None | False | None | False | 3379.2942 | 0 | 3497219 | 124918 | None | V-1 P.No 8 It.No 1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.
| Cum | 117.71 | 117.71 | 208.08 | False | None | None | False | None | False | 24493.0968 | 0 | 3497220 | 124918 | None | V-1 P.No 8 It.No 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m
| Cum | 126.38 | 126.38 | 444.12 | False | None | None | False | None | False | 56127.8856 | 0 | 3497221 | 124918 | None | V-1 P.No 8 It.No 1.15.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth
| Cum | 449.76 | 449.76 | 291.04 | False | None | None | False | None | False | 130898.1504 | 0 | 3497222 | 124918 | None | V-3 P.No 3 It.No 1.1A | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum
| Cum | 167.27 | 167.27 | 385.73 | False | None | None | False | None | False | 64521.0571 | 0 | 3497223 | 124918 | None | V-2 P.No 5 It.No 4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.
| Sqm | 146.2 | 146.2 | 624.4 | False | None | None | False | None | False | 91287.28 | 0 | 3497224 | 124918 | None | V-1 P.No 7 It.No 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
| Cum | 329.57 | 329.57 | 468.69 | False | None | None | False | None | False | 154466.1633 | 0 | 3497225 | 124918 | None | V-1 P.No 7 It.No 1.8 | Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.
| Cum | 587.29 | 587.29 | 407.88 | False | None | None | False | None | False | 239543.8452 | 0 | 3497226 | 124918 | None | V-1 P.No 15 It.No 2.1.3 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. Including FormWork
| Cum | 7420.37 | 7420.37 | 132.31 | False | None | None | False | None | False | 981789.1547 | 0 | 3497227 | 124918 | None | V-1 P.No 15 It.No 2.2.3 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including FormWorkFOOTINGS
| Cum | 8478.33 | 8478.33 | 147.29 | False | None | None | False | None | False | 1248773.2257 | 0 | 3497228 | 124918 | None | V-1 P.No 16 It.No 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork
COLUMNS
| Cum | 14413.41 | 14413.41 | 36.96 | False | None | None | False | None | False | 532719.6336 | 0 | 3497229 | 124918 | None | V-1 P.No 16 It.No 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork PLINTH BEAM
| Cum | 12717.72 | 12717.72 | 52.34 | False | None | None | False | None | False | 665645.4648 | 0 | 3497230 | 124918 | None | V-1 P.No 16 It.No 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork RCC BEAMS
| Cum | 12717.72 | 12717.72 | 29.99 | False | None | None | False | None | False | 381404.4228 | 0 | 3497231 | 124918 | None | V-1 P.No 16 It.No 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork
RCC SLAB
| Cum | 12717.72 | 12717.72 | 91.58 | False | None | None | False | None | False | 1164688.7976 | 0 | 3497232 | 124918 | None | V-1 P.No 16 It.No 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork
RCC STAIRCASE
| Cum | 12293.79 | 12293.79 | 6.1 | False | None | None | False | None | False | 74992.119 | 0 | 3497233 | 124918 | None | V-1 P.No 16 It.No 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork
LINTELS
| Cum | 13565.56 | 13565.56 | 10.7 | False | None | None | False | None | False | 145151.492 | 0 | 3497234 | 124918 | None | V-1 P.No 16 It.No 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork
| Cum | 9036.03 | 9036.03 | 7.83 | False | None | None | False | None | False | 70752.1149 | 0 | 3497235 | 124918 | None | V-2P43I8.16 a | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications. | Sqm | 1533.88 | 1533.88 | 5.58 | False | None | None | False | None | False | 8559.0504 | 0 | 3497236 | 124918 | None | V-1 P.No 18 It.No 2.11 a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.
| Tonne | 110837.22 | 110837.22 | 46.51 | False | None | None | False | None | False | 5155039.1022 | 0 | 3497237 | 124918 | None | 18-19 SR P.No 15 It.No 4.21 | Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications.
| Rmtr | 38.94 | 38.94 | 95.9 | False | None | None | False | None | False | 3734.346 | 0 | 3497238 | 124918 | None | Data Rate | Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge.
| Rmtr | 90.45 | 90.45 | 96.9 | False | None | None | False | None | False | 8764.605 | 0 | 3497239 | 124918 | None | V-2 P.No 9 It.No 5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)
| Cum | 7915.97 | 7915.97 | 14.35 | False | None | None | False | None | False | 113594.1695 | 0 | 3497240 | 124918 | None | V-2 P.No 14 It.No 6.80 | Providing Brick work with common burnt clay Non Modular bricks of
class designation 3.5 in superstructure above plinth level in all shapes andsizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost ofall materials, labour, scaffolding and usage charges of machinery & otherincidental charges complete as per the direction of engineer incharge ofwork. | Cum | 9873.59 | 9873.59 | 171.01 | False | None | None | False | None | False | 1688482.6259 | 0 | 3497241 | 124918 | None | V-2 P.No 14 It.No 6.12 | Providing Brick work with common burnt clay Non Modular bricks of
class designation 3.5 in superstructure above plinth level in all shapes andsizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost ofall materials, labour, scaffolding and usage charges of machinery & otherincidental charges complete as per the direction of engineer incharge ofwork. | Sqm | 1242.72 | 1242.72 | 143.9 | False | None | None | False | None | False | 178827.408 | 0 | 3497242 | 124918 | None | V-2 P.No 105 It.No 12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 35 mm thick both side Commercial
| Sqm | 4115.96 | 4115.96 | 34.23 | False | None | None | False | None | False | 140889.3108 | 0 | 3497243 | 124918 | None | V-2 P.No 100 It.No 12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.
| Cum | 122431.79 | 122431.79 | 0.79 | False | None | None | False | None | False | 96721.1141 | 0 | 3497244 | 124918 | None | V-2 P.No 105 It.No 12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.
| No | 1258.82 | 1258.82 | 15.0 | False | None | None | False | None | False | 18882.3 | 0 | 3497245 | 124918 | None | V-2 P.No 219 It.No 22.15.4 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm
| No | 464.63 | 464.63 | 15.0 | False | None | None | False | None | False | 6969.45 | 0 | 3497246 | 124918 | None | V-2 P.No 219 It.No 22.15.6 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm
| No | 185.85 | 185.85 | 30.0 | False | None | None | False | None | False | 5575.5 | 0 | 3497247 | 124918 | None | V-2 P.No 219 It.No 22.15.9 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm
| No | 86.73 | 86.73 | 60.0 | False | None | None | False | None | False | 5203.8 | 0 | 3497248 | 124918 | None | V-2 P.No 219 It.No 22.15.10 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm
| No | 123.9 | 123.9 | 15.0 | False | None | None | False | None | False | 1858.5 | 0 | 3497249 | 124918 | None | V-2 P.No 105 It.No 12.60 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
| No | 1303.43 | 1303.43 | 15.0 | False | None | None | False | None | False | 19551.45 | 0 | 3497250 | 124918 | None | V-2 P.No 69 It.No 10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm
| No | 74.34 | 74.34 | 90.0 | False | None | None | False | None | False | 6690.6 | 0 | 3497251 | 124918 | None | DATA RATE | Providing & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications. | Rmtr | 15.0 | 15.0 | 95.6 | False | None | None | False | None | False | 1434.0 | 0 | 3497252 | 124918 | None | V-2 P.No 110 It.No 12.90 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall
be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)
| Sqm | 8343.43 | 8343.43 | 53.4 | False | None | None | False | None | False | 445539.162 | 0 | 3497253 | 124918 | None | V-2 P.No 109 It.No 12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)
| Sqm | 7085.84 | 7085.84 | 4.86 | False | None | None | False | None | False | 34437.1824 | 0 | 3497254 | 124918 | None | V-2 P.No 86 It.No 11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding
| Kg | 208.15 | 208.15 | 1268.82 | False | None | None | False | None | False | 264104.883 | 0 | 3497255 | 124918 | None | V-2 P.No 111 It.No 12.93.1 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)Size 62 x 100mm
| Rmtr | 869.78 | 869.78 | 70.0 | False | None | None | False | None | False | 60884.6 | 0 | 3497256 | 124918 | None | V-2 P.No 112 It.No 12.94.1 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness
| Sqm | 4317.92 | 4317.92 | 23.52 | False | None | None | False | None | False | 101557.4784 | 0 | 3497257 | 124918 | None | V-2 P.No 107 It.No 12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
| No | 1380.25 | 1380.25 | 15.0 | False | None | None | False | None | False | 20703.75 | 0 | 3497258 | 124918 | None | V-2 P.No 109 It.No 11.25.2 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
| Kg | 168.5 | 168.5 | 86.4 | False | None | None | False | None | False | 14558.4 | 0 | 3497259 | 124918 | None | V-2 P.No 41 It.No 8.4.2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside)
| Sqm | 386.57 | 386.57 | 1559.25 | False | None | None | False | None | False | 602759.2725 | 0 | 3497260 | 124918 | None | V-2 P.No 43 It.No 8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 261.43 | 261.43 | 1071.99 | False | None | None | False | None | False | 280250.3457 | 0 | 3497261 | 124918 | None | V-2 P.No 50 It.No 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.
| Sqm | 123.9 | 123.9 | 2628.76 | False | None | None | False | None | False | 325703.364 | 0 | 3497262 | 124918 | None | V-2 P.No 42 It.No 8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside)
| Sqm | 432.41 | 432.41 | 458.28 | False | None | None | False | None | False | 198164.8548 | 0 | 3497263 | 124918 | None | V-2 P.No 41 It.No 8.3.1 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge.
| Sqm | 438.61 | 438.61 | 49.86 | False | None | None | False | None | False | 21869.0946 | 0 | 3497264 | 124918 | None | V-2 P.No 43 It.No 8.16.2 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide
| Rmtr | 47.08 | 47.08 | 841.9 | False | None | None | False | None | False | 39636.652 | 0 | 3497265 | 124918 | None | 18-19 SR P.No 69 It.No 10.5.2 | Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer.
| Sqm | 283.2 | 283.2 | 25.0 | False | None | None | False | None | False | 7080.0 | 0 | 3497266 | 124918 | None | V-2 P.No 54 It.No 8.79 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.
| Rmtr | 64.43 | 64.43 | 540.08 | False | None | None | False | None | False | 34797.3544 | 0 | 3497267 | 124918 | None | V-2 P.No 61 It.No 9.17.2 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm
| Sqm | 1455.83 | 1455.83 | 682.55 | False | None | None | False | None | False | 993676.7665 | 0 | 3497268 | 124918 | None | V-2 P.No 59 It.No 9.1 | Providing and laying Cement concrete flooring 40 mm thick with 20 mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete.
| Sqm | 558.79 | 558.79 | 28.28 | False | None | None | False | None | False | 15802.5812 | 0 | 3497269 | 124918 | None | V-2 P.No 62 It.No 9.22.2 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm
| Sqm | 1642.91 | 1642.91 | 455.1 | False | None | None | False | None | False | 747688.341 | 0 | 3497270 | 124918 | None | V-2 P.No 63 It.No 9.24 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.
| Sqm | 3533.63 | 3533.63 | 83.32 | False | None | None | False | None | False | 294422.0516 | 0 | 3497271 | 124918 | None | V-2 P.No 64 It.No 9.32 | Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. | Sqm | 3199.1 | 3199.1 | 34.56 | False | None | None | False | None | False | 110560.896 | 0 | 3497272 | 124918 | None | V-2 P.No 41 It.No 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 365.51 | 365.51 | 592.5 | False | None | None | False | None | False | 216564.675 | 0 | 3497273 | 124918 | None | V-2 P.No 150 It.No 15.7 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis)
| Sqm | 761.99 | 761.99 | 48.36 | False | None | None | False | None | False | 36849.8364 | 0 | 3497274 | 124918 | None | V-2 P.No 60 It.No 9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.
| Sqm | 1101.47 | 1101.47 | 27.51 | False | None | None | False | None | False | 30301.4397 | 0 | 3497275 | 124918 | None | V-2 P.No 65 It.No 9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.
| Sqm | 1795.31 | 1795.31 | 137.4 | False | None | None | False | None | False | 246675.594 | 0 | 3497276 | 124918 | None | V-2 P.No 85 It.No 11.28 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
| Kg | 700.04 | 700.04 | 360.9 | False | None | None | False | None | False | 252644.436 | 0 | 3497277 | 124918 | None | V-2 P.No 48 It.No 8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 157.35 | 157.35 | 2628.76 | False | None | None | False | None | False | 413635.386 | 0 | 3497278 | 124918 | None | V-2 P.No 46 It.No 8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 193.28 | 193.28 | 458.28 | False | None | None | False | None | False | 88576.3584 | 0 | 3497279 | 124918 | None | V-2 P.No 47 It.No 8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 61.95 | 61.95 | 57.36 | False | None | None | False | None | False | 3553.452 | 0 | 3497280 | 124918 | None | V-2 P.No 48 It.No 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 142.49 | 142.49 | 57.36 | False | None | None | False | None | False | 8173.2264 | 0 | 3497281 | 124918 | None | V-2 P.No 47 It.No 8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 65.67 | 65.67 | 139.97 | False | None | None | False | None | False | 9191.8299 | 0 | 3497282 | 124918 | None | V-2 P.No 54 It.No 8.82 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)"
| Sqm | 838.8 | 838.8 | 139.97 | False | None | None | False | None | False | 117406.836 | 0 | 3497283 | 124918 | None | V-2 P.No 181 It.no 18.1 | Providing and supplying aluminium extruded tubular and other alu- minium sections as per the architectural drawings and approved draw- ings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment.
| Kg | 504.27 | 504.27 | 304.2 | False | None | None | False | None | False | 153398.934 | 0 | 3497284 | 124918 | None | V-2 P.No 183 It.No 18.3 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. | Sqm | 3770.28 | 3770.28 | 40.2 | False | None | None | False | None | False | 151565.256 | 0 | 3497285 | 124918 | None | V-2P181I18.2 | Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:(a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum- smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality t design, within and all around the perimeter for holding glass.(d)Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.(e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete.This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-33010 testing method for a range upto 50 mm,.5. Seismic Movement Test (upto 30 mm) as per AAMA 501.409 testing method for Qualitative test, Tests to be conducted on site.6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml | Sqm | 3326.72 | 3326.72 | 40.2 | False | None | None | False | None | False | 133734.144 | 0 | 3497286 | 124918 | None | V-2 P.No 24 It.No 7.31 | Providing and fixing in position 12mm thick plaster of paris (Gypsum anhydrous) for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications. | Sqm | 1578.49 | 1578.49 | 104.1 | False | None | None | False | None | False | 164320.809 | 0 | 3497287 | 124918 | None | V-2 P.No 28 It.No 7.41 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per m2 including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge.
| Sqm | 2097.63 | 2097.63 | 156.11 | False | None | None | False | None | False | 327461.0193 | 0 | 3497288 | 124918 | None | V-2 P.No 63 It.No 9.29 | Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.
| Sqm | 5335.13 | 5335.13 | 4.776 | False | None | None | False | None | False | 25480.58088 | 0 | 3497289 | 124918 | None | Data rate | Providing and fixing aluminium coated and polyester based netted curtains complete. The work includes cost of all materials, labour charges, lead and lift, etc., complete.
| Rmtr | 2596.0 | 2596.0 | 20.0 | False | None | None | False | None | False | 51920.0 | 0 | 3497290 | 124918 | None | V-1 (CPWD) P.No 205 It.No 9.136 | Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to bepaid for separately).
| Rmtr | 1541.11 | 1541.11 | 30.0 | False | None | None | False | None | False | 46233.3 | 0 | 3497291 | 124918 | None | V-1 (CPWD) P.No 205 It.No 9.137 | Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge (panneling to be paid for separately).
| Sqm | 6790.22 | 6790.22 | 13.0 | False | None | None | False | None | False | 88272.86 | 0 | 3497292 | 124918 | None | V-2P72I10.19 | Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification. | Sqm | 4469.07 | 4469.07 | 12.0 | False | None | None | False | None | False | 53628.84 | 0 | 3497293 | 124918 | None | V-2 P.No 87 It.No 11.35.1.1 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in- charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications.
| Kg | 560.03 | 560.03 | 57.6 | False | None | None | False | None | False | 32257.728 | 0 | 3497294 | 124918 | None | V-2 P.No 89 It.No 11.37.1 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
| Sqm | 1224.13 | 1224.13 | 5.76 | False | None | None | False | None | False | 7050.9888 | 0 |
| 1720523219000 | 0 | None | None | Buildings | FIRST FLOOR(CIVIL WORKS) | 16859692.42 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3497295 | 124919 | None | V-1 P.No 16 It.No 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork COLUMNS
| Cum | 14557.55 | 14557.55 | 24.19 | False | None | None | False | None | False | 352147.1345 | 0 | 3497296 | 124919 | None | V-1 P.No 16 It.No 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork RCC BEAMS
| Cum | 13701.22 | 13701.22 | 28.98 | False | None | None | False | None | False | 397061.3556 | 0 | 3497297 | 124919 | None | V-1 P.No 16 It.No 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork RCC SLAB
| Cum | 12844.89 | 12844.89 | 92.58 | False | None | None | False | None | False | 1189179.9162 | 0 | 3497298 | 124919 | None | V-1 P.No 16 It.No 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork RCC STAIRCASE
| Cum | 12416.73 | 12416.73 | 5.84 | False | None | None | False | None | False | 72513.7032 | 0 | 3497299 | 124919 | None | V-1 P.No 16 It.No 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork LINTELS
| Cum | 13701.22 | 13701.22 | 13.27 | False | None | None | False | None | False | 181815.1894 | 0 | 3497300 | 124919 | None | V-1 P.No 16 It.No 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork
| Cum | 9126.39 | 9126.39 | 9.37 | False | None | None | False | None | False | 85514.2743 | 0 | 3497301 | 124919 | None | V-1 P.No 18 It.No 2.11 a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.
| Tonne | 111945.6 | 111945.6 | 25.51 | False | None | None | False | None | False | 2855732.256 | 0 | 3497302 | 124919 | None | 18-19 SR P.No 15 It.No 4.21 | Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No . KBS
| Rmtr | 38.94 | 38.94 | 108.6 | False | None | None | False | None | False | 4228.884 | 0 | 3497303 | 124919 | None | Data Rate | Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge.
| Rmtr | 86.14 | 86.14 | 108.6 | False | None | None | False | None | False | 9354.804 | 0 | 3497304 | 124919 | None | V-2 P.No 17 It.No 6.32 | roviding Brick work with common burnt clay Non Modular bricks of
class designation 3.5 in superstructure above plinth level in all shapes andsizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost ofall materials, labour, scaffolding and usage charges of machinery & otherincidental charges complete as per the direction of engineer incharge ofwork. | Cum | 9972.33 | 9972.33 | 225.93 | False | None | None | False | None | False | 2253048.5169 | 0 | 3497305 | 124919 | None | V-2 P.No 17 It.No 6.12 | Providing Half brick masonry with common burnt clay Non Modular bricksof class designation 3.5 in foundations and plinth in Cement mortar 1:3 (1cement : 3 coarse sand) including cost of all materials, labour, scaffoldingand usage charges of machinery & other incidental charges complete asper the direction of engineer incharge of work. | Sqm | 1255.14 | 1255.14 | 354.24 | False | None | None | False | None | False | 444620.7936 | 0 | 3497306 | 124919 | None | V-2 P.No 105 It.No 12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 35 mm thick both side Commercial
| Sqm | 4157.12 | 4157.12 | 39.9 | False | None | None | False | None | False | 165869.088 | 0 | 3497307 | 124919 | None | V-2 P.No 100 It.No 12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 123656.1 | 123656.1 | 0.97 | False | None | None | False | None | False | 119946.417 | 0 | 3497308 | 124919 | None | V-2 P.No 105 It.No 12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.
| No | 1271.41 | 1271.41 | 19.0 | False | None | None | False | None | False | 24156.79 | 0 | 3497309 | 124919 | None | V-2 P.No 218 It.No 22.15.2 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Handles 300mm
| No | 688.26 | 688.26 | 19.0 | False | None | None | False | None | False | 13076.94 | 0 | 3497310 | 124919 | None | V-2 P.No 219 It.No 22.15.4 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm
| No | 469.27 | 469.27 | 19.0 | False | None | None | False | None | False | 8916.13 | 0 | 3497311 | 124919 | None | V-2 P.No 219 It.No 22.15.6 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm
| No | 187.71 | 187.71 | 38.0 | False | None | None | False | None | False | 7132.98 | 0 | 3497312 | 124919 | None | V-2 P.No 219 It.No 22.15.9 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm
| No | 87.6 | 87.6 | 76.0 | False | None | None | False | None | False | 6657.6 | 0 | 3497313 | 124919 | None | V-2 P.No 219 It.No 22.15.10 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm
| No | 125.14 | 125.14 | 19.0 | False | None | None | False | None | False | 2377.66 | 0 | 3497314 | 124919 | None | V-2 P.No 105 It.No 12.60 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
| No | 1316.46 | 1316.46 | 19.0 | False | None | None | False | None | False | 25012.74 | 0 | 3497315 | 124919 | None | V-2 P.No 69 It.No 10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm
| No | 75.08 | 75.08 | 114.0 | False | None | None | False | None | False | 8559.12 | 0 | 3497316 | 124919 | None | DATA RATE | Providing & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications. | Rmtr | 15.0 | 15.0 | 117.8 | False | None | None | False | None | False | 1767.0 | 0 | 3497317 | 124919 | None | V-2 P.No 110 It.No 12.90 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall
be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)
| Sqm | 8426.86 | 8426.86 | 56.7 | False | None | None | False | None | False | 477802.962 | 0 | 3497318 | 124919 | None | V-2 P.No 109 It.No 12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)
| Sqm | 7156.7 | 7156.7 | 10.8 | False | None | None | False | None | False | 77292.36 | 0 | 3497319 | 124919 | None | V-2 P.No 86 It.No 11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding
| Kg | 210.23 | 210.23 | 1417.5 | False | None | None | False | None | False | 298001.025 | 0 | 3497320 | 124919 | None | V-2 P.No 111 It.No 12.93.1 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)Size 62 x 100mm
| Rmtr | 878.48 | 878.48 | 118.8 | False | None | None | False | None | False | 104363.424 | 0 | 3497321 | 124919 | None | V-2 P.No 112 It.No 12.94.1 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness
| Sqm | 4361.09 | 4361.09 | 37.8 | False | None | None | False | None | False | 164849.202 | 0 | 3497322 | 124919 | None | V-2 P.No 107 It.No 12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
| No | 1394.05 | 1394.05 | 19.0 | False | None | None | False | None | False | 26486.95 | 0 | 3497323 | 124919 | None | V-2 P.No 41 It.No 8.4.2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside)
| Sqm | 390.43 | 390.43 | 1715.31 | False | None | None | False | None | False | 669708.4833 | 0 | 3497324 | 124919 | None | V-2 P.No 43 It.No 8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 264.04 | 264.04 | 893.0 | False | None | None | False | None | False | 235787.72 | 0 | 3497325 | 124919 | None | V-2 P.No 50 It.No 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.
| Sqm | 103.87 | 103.87 | 2608.0 | False | None | None | False | None | False | 270892.96 | 0 | 3497326 | 124919 | None | V-2 P.No 42 It.No 8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside)
| Sqm | 436.74 | 436.74 | 634.14 | False | None | None | False | None | False | 276954.3036 | 0 | 3497327 | 124919 | None | V-2 P.No 41 It.No 8.3.1 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge.
| Sqm | 442.99 | 442.99 | 12.26 | False | None | None | False | None | False | 5431.0574 | 0 | 3497328 | 124919 | None | V-2 P.No 43 It.No 8.16.2 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide
| Rmtr | 47.55 | 47.55 | 841.9 | False | None | None | False | None | False | 40032.345 | 0 | 3497329 | 124919 | None | 18-19 SR P.No 69 It.No 10.5.2 | Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer.
| Sqm | 283.2 | 283.2 | 25.0 | False | None | None | False | None | False | 7080.0 | 0 | 3497330 | 124919 | None | V-2 P.No 54 It.no 8.79 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.
| Rmtr | 65.07 | 65.07 | 529.2 | False | None | None | False | None | False | 34435.044 | 0 | 3497331 | 124919 | None | V-2 P.No 61 It.No 9.17.2 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm
| Sqm | 1470.38 | 1470.38 | 340.0 | False | None | None | False | None | False | 499929.2 | 0 | 3497332 | 124919 | None | V-2 P.No 62 It.No 9.23 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye,
River Pink or equivalent. | Sqm | 3085.93 | 3085.93 | 310.59 | False | None | None | False | None | False | 958458.9987 | 0 | 3497333 | 124919 | None | V-2 P.No 64 It.No 9.30 | Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. | Sqm | 5388.49 | 5388.49 | 3.36 | False | None | None | False | None | False | 18105.3264 | 0 | 3497334 | 124919 | None | V-2 P.No 41 It.No 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 369.16 | 369.16 | 412.92 | False | None | None | False | None | False | 152433.5472 | 0 | 3497335 | 124919 | None | V-2 P.No 23 It.No 7.18 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.
| Cum | 2524.05 | 2524.05 | 24.7 | False | None | None | False | None | False | 62344.035 | 0 | 3497336 | 124919 | None | V-2 P.No 150 It.No 15.7 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis)
| Sqm | 769.6 | 769.6 | 138.66 | False | None | None | False | None | False | 106712.736 | 0 | 3497337 | 124919 | None | V-2 P.No 60 It.No 9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.
| Sqm | 1112.49 | 1112.49 | 82.32 | False | None | None | False | None | False | 91580.1768 | 0 | 3497338 | 124919 | None | V-2 P.No 65 It.No 9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.
| Sqm | 1813.26 | 1813.26 | 412.92 | False | None | None | False | None | False | 748731.3192 | 0 | 3497339 | 124919 | None | V-2 P.No 85 It.No 11.28 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
| Kg | 707.04 | 707.04 | 270.77 | False | None | None | False | None | False | 191445.2208 | 0 | 3497340 | 124919 | None | V-2 P.No 48 It.No 8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 158.93 | 158.93 | 2608.0 | False | None | None | False | None | False | 414489.44 | 0 | 3497341 | 124919 | None | V-2 P.No 46 It.No 8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 195.22 | 195.22 | 634.14 | False | None | None | False | None | False | 123796.8108 | 0 | 3497342 | 124919 | None | V-2 P.No 47 It.No 8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 62.57 | 62.57 | 67.5 | False | None | None | False | None | False | 4223.475 | 0 | 3497343 | 124919 | None | V-2 P.No 48 It.No 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 143.91 | 143.91 | 67.5 | False | None | None | False | None | False | 9713.925 | 0 | 3497344 | 124919 | None | V-2 P.No 47 It.No 8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 66.32 | 66.32 | 95.76 | False | None | None | False | None | False | 6350.8032 | 0 | 3497345 | 124919 | None | V-2 P.No 181 It.No 18.1 | Providing and supplying aluminium extruded tubular and other alu- minium sections as per the architectural drawings and approved draw- ings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment.
| Kg | 508.06 | 508.06 | 2340.0 | False | None | None | False | None | False | 1188860.4 | 0 | 3497346 | 124919 | None | V-2 P.No 183 It.No 18.3 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. | Sqm | 3807.98 | 3807.98 | 72.0 | False | None | None | False | None | False | 274174.56 | 0 | 3497347 | 124919 | None | V-2P181ITEM18.2 | Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:(a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum- smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect | Sqm | 3359.98 | 3359.98 | 72.0 | False | None | None | False | None | False | 241918.56 | 0 | 3497348 | 124919 | None | V-2P159ITM18.4 | Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge. | Sqm | 5203.28 | 5203.28 | 72.0 | False | None | None | False | None | False | 374636.16 | 0 | 3497349 | 124919 | None | V-2P159ITM18.50 | Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi -rigid, inorganic, non-combustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface 1 of the fibre glass insulation layer), of black non-woven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 g/m2,made of randomly oriented glass fibres distributed in a binder by a wet-lay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete | Sqm | 2426.45 | 2426.45 | 72.0 | False | None | None | False | None | False | 174704.4 | 0 | 3497350 | 124919 | None | V-2P84ITM11.25.2 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 170.19 | 170.19 | 761.4 | False | None | None | False | None | False | 129582.666 | 0 | 3497351 | 124919 | None | W.S & UGD SRP35ITM1201 | PVC pipes of 6 Kg/cm2 for 110mm(1.894) | Rmtr | 319.1 | 319.1 | 54.0 | False | None | None | False | None | False | 17231.4 | 0 | 3497352 | 124919 | None | V-2P61ITM9.14 | Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness. | Sqm | 441.74 | 441.74 | 345.14 | False | None | None | False | None | False | 152462.1436 | 0 |
| 1720523219000 | 0 | None | None | Buildings | WATER SUPPLY AND SANITARY WORKS | 1308144.11 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3497353 | 124920 | None | V-2P28ITM14.28 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
40mm dia pipes, From wash basin waste lines
| m | 270.1 | 270.1 | 45.0 | False | None | None | False | None | False | 12154.5 | 0 | 3497354 | 124920 | None | V-5P190ITM16.7.4 | Providing and fixing normal gauge polythene pipes of approved quality
with special flange compression type fittings of approved make including
trench excavation and refilling etc. for EXTERNAL WORKS with:"
50mm nominal bore pipes, From Sink & Urinal lines
| m | 172.22 | 172.22 | 35.0 | False | None | None | False | None | False | 6027.7 | 0 | 3497355 | 124920 | None | V-5P113ITM10.1.5 | Providing and fixing on wall face unplasticised Rigid PVC rain water
pipes conforming to IS : 13592 Type A, including jointing with seal ring
conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)
Single socketed pipes 100 mm diameter | m | 272.58 | 272.58 | 250.0 | False | None | None | False | None | False | 68145.0 | 0 | 3497356 | 124920 | None | V-5P125ITM13.48 | PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines | m | 509.23 | 509.23 | 175.0 | False | None | None | False | None | False | 89115.25 | 0 | 3497357 | 124920 | None | V-5ITM10.14.8 | Providing and installing at site of work P.V.C. pipes including cost of pipes
and specials and labour, including lowering into trenches, laying true
to line, level and perfect linking at joints leak proof including jointing
of approved type with all labour charges and all lift charges, handling
charges including encasing the pipe around to a depth not less than
15 cms with gravel or selected earth available from the excavation etc.
complete.110mm(weight of pipe -1.894 kg) | m | 360.55 | 360.55 | 100.0 | False | None | None | False | None | False | 36055.0 | 0 | 3497358 | 124920 | None | V-2P136ITM14.31 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. | Nos | 1511.58 | 1511.58 | 22.0 | False | None | None | False | None | False | 33254.76 | 0 | 3497359 | 124920 | None | V-2P118ITM13.9.2 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter | Nos | 345.68 | 345.68 | 18.0 | False | None | None | False | None | False | 6222.24 | 0 | 3497360 | 124920 | None | V-2P127ITM14.22B | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. | Nos | 6891.32 | 6891.32 | 18.0 | False | None | None | False | None | False | 124043.76 | 0 | 3497361 | 124920 | None | V-2P130ITM14.40.2 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. | Nos | 614.54 | 614.54 | 18.0 | False | None | None | False | None | False | 11061.72 | 0 | 3497362 | 124920 | None | CPWD SR, V-2,P370ITM17.78 | Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting,
of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. | Nos | 16152.29 | 16152.29 | 20.0 | False | None | None | False | None | False | 323045.8 | 0 | 3497363 | 124920 | None | V-2PA16I166 | C.P. Brass stop cock (concealed) 15 mm | Nos | 650.48 | 650.48 | 61.0 | False | None | None | False | None | False | 39679.28 | 0 | 3497364 | 124920 | None | V-2P132ITM14.7.1 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps | Nos | 3818.6 | 3818.6 | 22.0 | False | None | None | False | None | False | 84009.2 | 0 | 3497365 | 124920 | None | V-2P133ITM14.10.1.4 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mm | Nos | 5358.7 | 5358.7 | 1.0 | False | None | None | False | None | False | 5358.7 | 0 | 3497366 | 124920 | None | V-2P122ITM13.32.1 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
GROUND FLOOR
15 mm nominal dia Pipes
| m | 382.85 | 382.85 | 50.0 | False | None | None | False | None | False | 19142.5 | 0 | 3497367 | 124920 | None | V-2P122ITM13.32.1 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
15 mm nominal dia Pipes
| m | 382.85 | 382.85 | 50.0 | False | None | None | False | None | False | 19142.5 | 0 | 3497368 | 124920 | None | V-2P122ITM13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
20 mm nominal dia Pipes
| m | 469.58 | 469.58 | 360.0 | False | None | None | False | None | False | 169048.8 | 0 | 3497369 | 124920 | None | V-2P122ITM13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
25 mm nominal dia Pipes
| m | 591.0 | 591.0 | 50.0 | False | None | None | False | None | False | 29550.0 | 0 | 3497370 | 124920 | None | V-2P122ITM13.33 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)"
External & Shafts & Terrace
25 mm nominal dia Pipes
| m | 366.74 | 366.74 | 100.0 | False | None | None | False | None | False | 36674.0 | 0 | 3497371 | 124920 | None | CPWD SR, V-2,P377ITM1927 | Brass full way valve with C.I. wheel (screwed end) 25 mm dia | Each | 442.5 | 442.5 | 8.0 | False | None | None | False | None | False | 3540.0 | 0 | 3497372 | 124920 | None | V2P123ITM13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. | Ltr | 11.15 | 11.15 | 3500.0 | False | None | None | False | None | False | 39025.0 | 0 | 3497373 | 124920 | None | MARKET RATE | Providing, fixing, testing and commissioning of deep seal PVC multi inlet floor trap of self cleansing design moulded or fabricated with CP grating, rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste including making good the floors etc., complete as directed by the Engineer in charge & approved quality confirming to ISI or BIS Standards
Ground Toilet
10Cms X 7.5Cms
| Nos | 371.7 | 371.7 | 52.0 | False | None | None | False | None | False | 19328.4 | 0 | 3497374 | 124920 | None | MARKET RATE | Supplying, installing, testing and commissioning approved make Submersible Pump made of C.I Construction suitable for building application. Thequoted rate shall also include for auto lvl.controller with cabling between hePumps, control panel, UGR & OHT etc.,. complete.approx. Length of cable = 80. providing necessary safety devices viz. dry run protection, over load relays etc., complete working on 230V, 50Hz, 1Ph, with starter,.(1 no. working and 1no. Standby ) Sump To OHT (DOMESTIC)2.00 HP | Each | 41300.0 | 41300.0 | 2.0 | False | None | None | False | None | False | 82600.0 | 0 | 3497375 | 124920 | None | MARKET RATE | Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). | Nos | 2183.0 | 2183.0 | 20.0 | False | None | None | False | None | False | 43660.0 | 0 | 3497376 | 124920 | None | MARKET RATE | Supplying, installing, testing and commissioning approved make water level controller (RMG or equivalent )for the Underground Sump and overhead tank. The quoted rate shall include for necessary wiring in PVC conduit between the control panel, underground sump and overhead tank. (length of cable approx. 150 mts.) | Each | 8260.0 | 8260.0 | 1.0 | False | None | None | False | None | False | 8260.0 | 0 |
| 1720523219000 | 0 | None | None | Buildings | EXTERNAL WS AND SANITARY WORKS | 243908.92 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3497377 | 124921 | None | V-1P8ITM1.5.1 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage
& other appurtenances required to complete the work."
In ordinary/soft rock without blasting upto 1.5 m depth
For Sewer allround
| Cum | 449.76 | 449.76 | 68.0 | False | None | None | False | None | False | 30583.68 | 0 | 3497378 | 124921 | None | V-1P7ITM1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 329.57 | 329.57 | 68.0 | False | None | None | False | None | False | 22410.76 | 0 | 3497379 | 124921 | None | V-5P113ITM10.2.4 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Sanitary Work ).Pipes of SN4, 160mm dia. | m | 713.66 | 713.66 | 150.0 | False | None | None | False | None | False | 107049.0 | 0 | 3497380 | 124921 | None | V-5P189ITM16.9 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(INSPECTION CHAMBER)
| Nos | 6757.51 | 6757.51 | 12.0 | False | None | None | False | None | False | 81090.12 | 0 | 3497381 | 124921 | None | SR 2018-19ITM12.112.2 | Providing stoneware gully trap of approved quality and make fixing in M-15 and plastering with CM 1:3 wherever necessary.( Rate includes cost of all materials, fixtures and lead).15cms x 10cms | Nos | 346.92 | 346.92 | 8.0 | False | None | None | False | None | False | 2775.36 | 0 |
| 1720523219000 | 0 | None | None | Buildings | INTERNAL ELECTRICAL WORKS | 2730510.39 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3497382 | 124922 | None | V-6 PWD SR P.No 5 It.No 2.2.1 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet. Short point up to 3Mtr from tapping point to out let via switch | Point | 333.29 | 333.29 | 68.0 | False | None | None | False | None | False | 22663.72 | 0 | 3497383 | 124922 | None | V-6 PWD SR P.No 5 It.No 2.2.2 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch | Point | 469.58 | 469.58 | 100.0 | False | None | None | False | None | False | 46958.0 | 0 | 3497384 | 124922 | None | V-6 PWD SR P.No 5 It.No 2.2.3 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch | Point | 687.65 | 687.65 | 130.0 | False | None | None | False | None | False | 89394.5 | 0 | 3497385 | 124922 | None | V-6 PWD SR P.No 5 It.No 2.2.4 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches | Point | 838.8 | 838.8 | 25.0 | False | None | None | False | None | False | 20970.0 | 0 | 3497386 | 124922 | None | V-6 PWD SR P.No 8 It.No 3.4.1 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2Way | Each | 170.98 | 170.98 | 100.0 | False | None | None | False | None | False | 17098.0 | 0 | 3497387 | 124922 | None | V-6 PWD SR P.No 8 It.No 3.4.3 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way | Each | 219.3 | 219.3 | 15.0 | False | None | None | False | None | False | 3289.5 | 0 | 3497388 | 124922 | None | V-6 PWD SR P.No 8 It.No 3.4.4 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way | Each | 272.58 | 272.58 | 60.0 | False | None | None | False | None | False | 16354.8 | 0 | 3497389 | 124922 | None | V-6 PWD SR P.No 8 It.No 3.4.5 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way | Each | 323.38 | 323.38 | 20.0 | False | None | None | False | None | False | 6467.6 | 0 | 3497390 | 124922 | None | V-6 PWD SR P.No 8 It.No 3.4.6 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way | Each | 395.24 | 395.24 | 70.0 | False | None | None | False | None | False | 27666.8 | 0 | 3497391 | 124922 | None | V-6 PWD SR P.No 8 It.No 3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module | Each | 199.48 | 199.48 | 100.0 | False | None | None | False | None | False | 19948.0 | 0 | 3497392 | 124922 | None | V-6 PWD SR P.No 8 It.No 3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module | Each | 216.83 | 216.83 | 15.0 | False | None | None | False | None | False | 3252.45 | 0 | 3497393 | 124922 | None | V-6 PWD SR P.No 8 It.No 3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module | Each | 289.93 | 289.93 | 60.0 | False | None | None | False | None | False | 17395.8 | 0 | 3497394 | 124922 | None | V-6 PWD SR P.No 8 It.No 3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module | Each | 351.88 | 351.88 | 20.0 | False | None | None | False | None | False | 7037.6 | 0 | 3497395 | 124922 | None | V-6 PWD SR P.No 8 It.No 3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module | Each | 426.22 | 426.22 | 70.0 | False | None | None | False | None | False | 29835.4 | 0 | 3497396 | 124922 | None | V-6 PWD SR P.No 9 It.No 3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch | Each | 126.38 | 126.38 | 265.0 | False | None | None | False | None | False | 33490.7 | 0 | 3497397 | 124922 | None | V-6 PWD SR P.No 9 It.No 3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket | Each | 211.87 | 211.87 | 210.0 | False | None | None | False | None | False | 44492.7 | 0 | 3497398 | 124922 | None | V-6 PWD SR P.No 9 It.No 3.6.4 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. | Each | 442.32 | 442.32 | 62.0 | False | None | None | False | None | False | 27423.84 | 0 | 3497399 | 124922 | None | V-6 PWD SR P.No 9 It.No 3.6.9 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch | Each | 403.91 | 403.91 | 20.0 | False | None | None | False | None | False | 8078.2 | 0 | 3497400 | 124922 | None | V-6 PWD SR P.No 9 It.No 3.6.10 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket | Each | 292.4 | 292.4 | 25.0 | False | None | None | False | None | False | 7310.0 | 0 | 3497401 | 124922 | None | V-6 PWD SR P.No 9 It.No 3.6.7 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch | Each | 223.02 | 223.02 | 5.0 | False | None | None | False | None | False | 1115.1 | 0 | 3497402 | 124922 | None | V-6 PWD SR P.No 4 It.No 1.13 | Supplyin and Fixing Metal Fan Box with Round Hook. | No | 201.96 | 201.96 | 62.0 | False | None | None | False | None | False | 12521.52 | 0 | 3497403 | 124922 | None | V-6 PWD SR P.No 2 It.No 1.2.1 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 19/20mm dia 2mm thick | Rmtr | 81.77 | 81.77 | 2600.0 | False | None | None | False | None | False | 212602.0 | 0 | 3497404 | 124922 | None | V-6 PWD SR P.No 2 It.No 1.2.2 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick | Rmtr | 96.64 | 96.64 | 2500.0 | False | None | None | False | None | False | 241600.0 | 0 | 3497405 | 124922 | None | V-6 PWD SR P.No 2 It.No 1.2.3 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 32mm dia 2.5mm thick | Rmtr | 127.62 | 127.62 | 300.0 | False | None | None | False | None | False | 38286.0 | 0 | 3497406 | 124922 | None | V-6 PWD SR P.No 2 It.No 1.3.1 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick | Rmtr | 84.25 | 84.25 | 1300.0 | False | None | None | False | None | False | 109525.0 | 0 | 3497407 | 124922 | None | V-6 PWD SR P.No 2 It.No 1.3.2 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick | Rmtr | 97.88 | 97.88 | 1200.0 | False | None | None | False | None | False | 117456.0 | 0 | 3497408 | 124922 | None | V-6 PWD SR P.No 2 It.No 1.3.3 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick | Rmtr | 122.66 | 122.66 | 150.0 | False | None | None | False | None | False | 18399.0 | 0 | 3497409 | 124922 | None | V-6 PWD SR P.No 5 It.No 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 1.5 sqmm | Rmtr | 32.21 | 32.21 | 1400.0 | False | None | None | False | None | False | 45094.0 | 0 | 3497410 | 124922 | None | V-6 PWD SR P.No 5 It.No 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 2.5 sqmm | Rmtr | 52.04 | 52.04 | 2800.0 | False | None | None | False | None | False | 145712.0 | 0 | 3497411 | 124922 | None | V-6 PWD SR P.No 5 It.No 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 4 sqmm | Rmtr | 78.06 | 78.06 | 1000.0 | False | None | None | False | None | False | 78060.0 | 0 | 3497412 | 124922 | None | V-6 PWD SR P.No 5 It.No 2.3.5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 6 sqmm | Rmtr | 113.99 | 113.99 | 450.0 | False | None | None | False | None | False | 51295.5 | 0 | 3497413 | 124922 | None | V-6 PWD SR P.No 18 It.No 5.19.11 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 4 Way TP & N | Each | 5003.08 | 5003.08 | 4.0 | False | None | None | False | None | False | 20012.32 | 0 | 3497414 | 124922 | None | V-6 PWD SR P.No 18 It.No 5.19.12 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N | Each | 6120.66 | 6120.66 | 3.0 | False | None | None | False | None | False | 18361.98 | 0 | 3497415 | 124922 | None | V-6 PWD SR P.No 18 It.No 5.18.8 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3phase I single door with powder coated painting. Made out of 14 SWG MS enclosure | Each | 2297.11 | 2297.11 | 1.0 | False | None | None | False | None | False | 2297.11 | 0 | 3497416 | 124922 | None | V-6 PWD SR P.No 17 It.No 5.18.1 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP | Each | 514.19 | 514.19 | 108.0 | False | None | None | False | None | False | 55532.52 | 0 | 3497417 | 124922 | None | V-6 PWD SR P.No 17 It.No 5.18.9 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 | Each | 2127.36 | 2127.36 | 7.0 | False | None | None | False | None | False | 14891.52 | 0 | 3497418 | 124922 | None | V-6 PWD SR P.No 18 It.No 5.20.8 | Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 4 pole | Each | 6377.13 | 6377.13 | 7.0 | False | None | None | False | None | False | 44639.91 | 0 | 3497419 | 124922 | None | V-6 PWD SR P.No 18 It.No 5.20.1 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 pole
| Each | 5299.2 | 5299.2 | 1.0 | False | None | None | False | None | False | 5299.2 | 0 | 3497420 | 124922 | None | V-6 BSR P.No 13 It.No 32.05 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 16 sqmm | Km | 192613.7 | 192613.7 | 0.06 | False | None | None | False | None | False | 11556.822 | 0 | 3497421 | 124922 | None | V-6 BSR P.No 13 It.No 32.03 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 10sqmm | Km | 156042.14 | 156042.14 | 0.1 | False | None | None | False | None | False | 15604.214 | 0 | 3497422 | 124922 | None | V-6 BSR P.No 13 It.No 32.09 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm | Km | 219103.52 | 219103.52 | 0.08 | False | None | None | False | None | False | 17528.2816 | 0 | 3497423 | 124922 | None | V-6 BSR P.No 13 It.No 32.14 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 95 sqmm | Km | 539741.85 | 539741.85 | 0.1 | False | None | None | False | None | False | 53974.185 | 0 | 3497424 | 124922 | None | PWD SR 19-20 ITM 6.11.3 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia | Each | 151.16 | 151.16 | 4.0 | False | None | None | False | None | False | 604.64 | 0 | 3497425 | 124922 | None | PWD SR 19-20 ITM 6.11.4 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 45mm dia | Each | 240.37 | 240.37 | 6.0 | False | None | None | False | None | False | 1442.22 | 0 | 3497426 | 124922 | None | 31.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as
directed by the departmental staff"
2.5 sqmm to 25 sqmm
| Km | 20021.0 | 20021.0 | 0.16 | False | None | None | False | None | False | 3203.36 | 0 | 3497427 | 124922 | None | 31.06 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as
directed by the departmental staff"
35 sqmm to 95 sqmm
| Km | 29298.63 | 29298.63 | 0.18 | False | None | None | False | None | False | 5273.7534 | 0 | 3497428 | 124922 | None | V-6 PWD SR P 54 ITM 12.57 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C.
cutouts and other equipment's on the meter board using 40 mm dia
2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be
filled with equal proportion of salt and charcoal 150 mm all-round the
pipe to complete depth. The connection from the pipe to the conduit
etc., is to be established through GI wire of size as per lSI specification
7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts
etc., the pipe shall have 16 through holes of 12 mm dia | No | 5273.18 | 5273.18 | 8.0 | False | None | None | False | None | False | 42185.44 | 0 | 3497429 | 124922 | None | V-6 PWD SR P 54 Itm 12.58.2 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip | Rmtr | 101.6 | 101.6 | 50.0 | False | None | None | False | None | False | 5080.0 | 0 | 3497430 | 124922 | None | V-6 PWD SR P 55 ITM 12.58.3 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip 25x6mm GI strip
| Rmtr | 158.6 | 158.6 | 50.0 | False | None | None | False | None | False | 7930.0 | 0 | 3497431 | 124922 | None | V-6 PWD SR P 44 Itm 11.5.2 | Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W | Each | 1096.52 | 1096.52 | 55.0 | False | None | None | False | None | False | 60308.6 | 0 | 3497432 | 124922 | None | V-6 PWD SR P 43 Itm 11.3.2 | Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w | Each | 854.91 | 854.91 | 85.0 | False | None | None | False | None | False | 72667.35 | 0 | 3497433 | 124922 | None | V-6 PWD SR P 47 ITM 11.11.3 | Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K | Each | 184.61 | 184.61 | 5.0 | False | None | None | False | None | False | 923.05 | 0 | 3497434 | 124922 | None | V-6 PWD SR P 47 ITM 11.11.5 | Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K | Each | 333.29 | 333.29 | 40.0 | False | None | None | False | None | False | 13331.6 | 0 | 3497435 | 124922 | None | V-6 PWD SR P 45 ITM 11.6.3 | Supplying of recess mounting non integral type .LED . W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded fase ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, , THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' - 34 -36watt | Each | 5641.17 | 5641.17 | 2.0 | False | None | None | False | None | False | 11282.34 | 0 | 3497436 | 124922 | None | V-6 PWD SR P 46 ITM 11.8.2 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts | No | 4985.74 | 4985.74 | 4.0 | False | None | None | False | None | False | 19942.96 | 0 | 3497437 | 124922 | None | V-6 PWD SR P 30 ITM 6.1 | Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. | Each | 1848.59 | 1848.59 | 20.0 | False | None | None | False | None | False | 36971.8 | 0 | 3497438 | 124922 | None | V-6 PWD SR P 30 ITM 6.4.1 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm) | Each | 3697.18 | 3697.18 | 62.0 | False | None | None | False | None | False | 229225.16 | 0 | 3497439 | 124922 | None | V-6 PWD SR P 52 ITM 12.46 | Supplying & Fixing of 70-150 Watts lamp holder 2 Pin | Each | 78.06 | 78.06 | 95.0 | False | None | None | False | None | False | 7415.7 | 0 | 3497440 | 124922 | None | V-6 PWD SR P 56 ITM 13.7.1 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders | Each | 151.16 | 151.16 | 235.0 | False | None | None | False | None | False | 35522.6 | 0 | 3497441 | 124922 | None | V-6 PWD SR P 57 ITM 13.11 | Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size
wooden board and wired. | Each | 390.29 | 390.29 | 62.0 | False | None | None | False | None | False | 24197.98 | 0 | 3497442 | 124922 | None | V-6 PWD SR P 57 ITM 13.13 | Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. | Each | 875.97 | 875.97 | 20.0 | False | None | None | False | None | False | 17519.4 | 0 | 3497443 | 124922 | None | V-6 PWD SR P 56 ITM 13.4.1 | Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length | Each | 1810.18 | 1810.18 | 4.0 | False | None | None | False | None | False | 7240.72 | 0 | 3497444 | 124922 | None | V-6 PWD SR P 56 ITM 13.5 | Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. | Each | 200.72 | 200.72 | 4.0 | False | None | None | False | None | False | 802.88 | 0 | 3497445 | 124922 | None | V-6 PWD SR P 20 ITM 5.42.1 | Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete | Sq CM | 0.62 | 0.62 | 140000.0 | False | None | None | False | None | False | 86800.0 | 0 | 3497446 | 124922 | None | V-6 PWD SR P 20 ITM 5.40.2 | Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips | Rmtr | 4255.97 | 4255.97 | 8.0 | False | None | None | False | None | False | 34047.76 | 0 | 3497447 | 124922 | None | V-6 PWD SR P 20 ITM 5.41.1 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm | Rmtr | 377.9 | 377.9 | 12.0 | False | None | None | False | None | False | 4534.8 | 0 | 3497448 | 124922 | None | V-6 PWD SR P 20 ITM 5.41.4 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel | Rmtr | 936.68 | 936.68 | 12.0 | False | None | None | False | None | False | 11240.16 | 0 | 3497449 | 124922 | None | V-6 PWD SR P 16 ITM 5.15.9 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 100Amps 25kA | Each | 10515.39 | 10515.39 | 1.0 | False | None | None | False | None | False | 10515.39 | 0 | 3497450 | 124922 | None | V-6 PWD SR P 18 ITM 5.17.9 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898
50-63Amps TPN
| Each | 2972.36 | 2972.36 | 6.0 | False | None | None | False | None | False | 17834.16 | 0 | 3497451 | 124922 | None | V-6 PWD SR P 19 ITM 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C | Each | 638.09 | 638.09 | 12.0 | False | None | None | False | None | False | 7657.08 | 0 | 3497452 | 124922 | None | V-6 PWD SR P 19 ITM 5.34 | Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound | Each | 696.32 | 696.32 | 3.0 | False | None | None | False | None | False | 2088.96 | 0 | 3497453 | 124922 | None | 5.34 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery | Kvar | 594.72 | 594.72 | 20.0 | False | None | None | False | None | False | 11894.4 | 0 | 3497454 | 124922 | None | 5.31 | Supplying and fixing Trivector Meter suitable for operation LT operation and -CT operated meter in polycarbonate body in class 0.5 accuracy as per IS 14697 and completely wire | Each | 5439.21 | 5439.21 | 1.0 | False | None | None | False | None | False | 5439.21 | 0 | 3497455 | 124922 | None | 5.39 | Supplying, fixing and wiring Automatic Power Factor controller fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three place LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect I disconnect banks, with automatic recognition or with standard programs. | Each | 26811.96 | 26811.96 | 1.0 | False | None | None | False | None | False | 26811.96 | 0 | 3497456 | 124922 | None | 9.3.1 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, | Each | 18692.79 | 18692.79 | 1.0 | False | None | None | False | None | False | 18692.79 | 0 | 3497457 | 124922 | None | 9.5.9 | Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries.
150 AH capacity
| Each | 19693.91 | 19693.91 | 1.0 | False | None | None | False | None | False | 19693.91 | 0 | 3497458 | 124922 | None | 29.03 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr,Supplying and Displaying necessary Danger Boards and Lighting, Using sightRails and Sign Boards at every 100 Mtr wherever necessary as directed
In soil (hard)
| Cum | 481.97 | 481.97 | 80.0 | False | None | None | False | None | False | 38557.6 | 0 | 3497459 | 124922 | None | 13.4.1 | Single bracket 1.5 Mtr. Length | Each | 1810.18 | 1810.18 | 4.0 | False | None | None | False | None | False | 7240.72 | 0 | 3497460 | 124922 | None | V-6 PWD SR P 9 ITM 3.6.2 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch | Each | 205.67 | 205.67 | 8.0 | False | None | None | False | None | False | 1645.36 | 0 | 3497461 | 124922 | None | 31.06 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as
directed by the departmental staff"
35 sqmm to 95 sqmm
| Km | 29298.63 | 29298.63 | 0.18 | False | None | None | False | None | False | 5273.7534 | 0 | 3497462 | 124922 | None | 5.17.7 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898
32Amps TPN
| Each | 2201.7 | 2201.7 | 3.0 | False | None | None | False | None | False | 6605.1 | 0 | 3497463 | 124922 | None | 12.27 | Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply | No | 64.43 | 64.43 | 25.0 | False | None | None | False | None | False | 1610.75 | 0 | 3497464 | 124922 | None | 11.11.7 | Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffusercomprising of LED source with CCT 6500 degree K, CRI70efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should of lamp wattage.short circuit & open circuit protection to be integrated in the circuit, THD less than 20 Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABLCPRI accredited laboratory with 2 years Warranty against anymanufacturing defect working under standard electrical condition.
18 W,6500K | Each | 527.81 | 527.81 | 50.0 | False | None | None | False | None | False | 26390.5 | 0 | 3497465 | 124922 | None | 49.05 | Supplying and fixing of class A (medium duty) GI pipe of wall thick ness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV class.
50mm
| Mtr | 474.54 | 474.54 | 5.0 | False | None | None | False | None | False | 2372.7 | 0 |
| 1720523219000 | 0 | None | None | Buildings | SUMP TANK | 522012.61 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3497466 | 124923 | None | V-1P8ITM1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 126.38 | 126.38 | 55.46 | False | None | None | False | None | False | 7009.0348 | 0 | 3497467 | 124923 | None | V-1P8ITM1.15.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth
water sump Upto 3.0 mtrs depth
Consider 10% Qty as soft rock/ordinary rock
| Cum | 449.76 | 449.76 | 4.02 | False | None | None | False | None | False | 1808.0352 | 0 | 3497468 | 124923 | None | V-1P9ITM1.15.2 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Depth exceeding 1.5 m, but not exceeding 3 m
water sump Upto 3.0 mtrs depth
Consider 10% Qty as soft rock/ordinary rock
| Cum | 526.58 | 526.58 | 2.14 | False | None | None | False | None | False | 1126.8812 | 0 | 3497469 | 124923 | None | V-3P3ITMA | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km)
For 5 KM lead = 2.5 x 1.28 x 5 + loading and Unloading charges =68 = 84.00/cum
| Cum | 167.27 | 167.27 | 50.0 | False | None | None | False | None | False | 8363.5 | 0 | 3497470 | 124923 | None | V-1P7ITM1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Total E/W Qty. It no. 2 and 3 4
DeductFire fighting,raw water,treated water sump Rain water sump
| Cum | 329.57 | 329.57 | 11.39 | False | None | None | False | None | False | 3753.8023 | 0 | 3497471 | 124923 | None | V-1P15ITM2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates
water sump
| Cum | 7420.37 | 7420.37 | 2.18 | False | None | None | False | None | False | 16176.4066 | 0 | 3497472 | 124923 | None | V-1P15ITM2.4.2 | Providing and laying in position Cement Concrete for all Sub structures ofbuilding, Irrigation works, Sub structure works of bridges, Drain works &other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt
crushed graded coarse aggregates and fine aggregates as per relevant ISCodes machine mixed with super plasticisers, laid in layers, well compactedusing needle vibrators, providing weep holes wherever necessary, including
all lead & lifts, cost of all materials of quality, confirming to the requirementsof relevant IS codes, labour, Usage charges of machinery, curing and all other
appurtenances required to complete the work as per technical specifications 2 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates"
A. Raft
water sump
| Cum | 8069.22 | 8069.22 | 4.37 | False | None | None | False | None | False | 35262.4914 | 0 | 3497473 | 124923 | None | V-1P15ITM2.4.2 | Providing and laying in position Cement Concrete for all Sub structures ofbuilding, Irrigation works, Sub structure works of bridges, Drain works &other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt
crushed graded coarse aggregates and fine aggregates as per relevant ISCodes machine mixed with super plasticisers, laid in layers, well compactedusing needle vibrators, providing weep holes wherever necessary, including
all lead & lifts, cost of all materials of quality, confirming to the requirementsof relevant IS codes, labour, Usage charges of machinery, curing and all other
appurtenances required to complete the work as per technical specifications 2 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates"
sump tank-walls
Sump tank
| Cum | 13318.13 | 13318.13 | 8.28 | False | None | None | False | None | False | 110274.1164 | 0 | 3497474 | 124923 | None | V-1P15ITM2.4.2 | Providing and laying in position Cement Concrete for all Sub structures ofbuilding, Irrigation works, Sub structure works of bridges, Drain works &other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt
crushed graded coarse aggregates and fine aggregates as per relevant ISCodes machine mixed with super plasticisers, laid in layers, well compactedusing needle vibrators, providing weep holes wherever necessary, including
all lead & lifts, cost of all materials of quality, confirming to the requirementsof relevant IS codes, labour, Usage charges of machinery, curing and all other
appurtenances required to complete the work as per technical specifications 2 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates"
Sump tank
Cover slab
| Cum | 11751.3 | 11751.3 | 4.37 | False | None | None | False | None | False | 51353.181 | 0 | 3497475 | 124923 | None | V-1P18ITM2.11 a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.
Raft
Roof slabs
Sump Walls
| Tonne | 110837.22 | 110837.22 | 2.23 | False | None | None | False | None | False | 247167.0006 | 0 | 3497476 | 124923 | None | V-2P150ITM15.7 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis)
GROUND FLOOR
Sump
Sump Base
| Cum | 761.99 | 761.99 | 27.14 | False | None | None | False | None | False | 20680.4086 | 0 | 3497477 | 124923 | None | V-2P41ITM8.3.1 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge.
Inside Wall
Sump Wall
Base slab
| Cum | 438.61 | 438.61 | 27.14 | False | None | None | False | None | False | 11903.8754 | 0 | 3497478 | 124923 | None | V-2P41ITM8.4.2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
cover Slab
| Cum | 386.57 | 386.57 | 5.52 | False | None | None | False | None | False | 2133.8664 | 0 | 3497479 | 124923 | None | XXIV18-19 SR624 | C. I Manhole covers with frame 610 * 455mm size (38kgs)
| No | 2500.0 | 2500.0 | 2.0 | False | None | None | False | None | False | 5000.0 | 0 |
| 1720523219000 | 0 | None | None | Buildings | SEPTIC Tank | 831371.7 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3497480 | 124924 | None | V-3p7itm2.5A | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle
Septic tank
| Sqm | 486.93 | 486.93 | 36.06 | False | None | None | False | None | False | 17558.6958 | 0 | 3497481 | 124924 | None | V-1p8itm1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth
Septic tank
Soak pit
| Cum | 117.71 | 117.71 | 18.03 | False | None | None | False | None | False | 2122.3113 | 0 | 3497482 | 124924 | None | V-1p8itm1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m
0.00 Mtrs - 3.00 Mtrs do- Ordinary/Hard soil-Mechanical Means
Septic tank
Soak pit
| Cum | 126.38 | 126.38 | 97.36 | False | None | None | False | None | False | 12304.3568 | 0 | 3497483 | 124924 | None | V-1p8itm1.15.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth
Septic tank
| Cum | 449.76 | 449.76 | 5.41 | False | None | None | False | None | False | 2433.2016 | 0 | 3497484 | 124924 | None | V-1p9itm1.15.2 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Depth exceeding 1.5 m, but not exceeding 3 m
Septic tank
Soak pit
| Cum | 526.58 | 526.58 | 5.41 | False | None | None | False | None | False | 2848.7978 | 0 | 3497485 | 124924 | None | V-3p3itmA | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km)
For 10 KM lead = 2.5 x 1.28 x 10 + loading and Unloading charges =68 = 100.00
| Cum | 167.27 | 167.27 | 108.18 | False | None | None | False | None | False | 18095.2686 | 0 | 3497486 | 124924 | None | V-1P15ITM2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 3.08 | False | None | None | False | None | False | 22854.7396 | 0 | 3497487 | 124924 | None | V-1P15ITM2.4.2 | Providing and laying in position Cement Concrete for all Sub structures ofbuilding, Irrigation works, Sub structure works of bridges, Drain works &other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt
crushed graded coarse aggregates and fine aggregates as per relevant ISCodes machine mixed with super plasticisers, laid in layers, well compactedusing needle vibrators, providing weep holes wherever necessary, including
all lead & lifts, cost of all materials of quality, confirming to the requirementsof relevant IS codes, labour, Usage charges of machinery, curing and all other
appurtenances required to complete the work as per technical specifications 2 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates"
BOTTOM SLAB
| Cum | 8069.22 | 8069.22 | 4.11 | False | None | None | False | None | False | 33164.4942 | 0 | 3497488 | 124924 | None | V-1P15ITM2.4.2 | Providing and laying in position Cement Concrete for all Sub structures ofbuilding, Irrigation works, Sub structure works of bridges, Drain works &other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt
crushed graded coarse aggregates and fine aggregates as per relevant ISCodes machine mixed with super plasticisers, laid in layers, well compactedusing needle vibrators, providing weep holes wherever necessary, including
all lead & lifts, cost of all materials of quality, confirming to the requirementsof relevant IS codes, labour, Usage charges of machinery, curing and all other
appurtenances required to complete the work as per technical specifications 2 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates"
TOP SLAB
Septic tank
Soak pit
| Cum | 9401.04 | 9401.04 | 3.08 | False | None | None | False | None | False | 28955.2032 | 0 | 3497489 | 124924 | None | V-1P15ITM2.4.2 | Providing and laying in position Cement Concrete for all Sub structures ofbuilding, Irrigation works, Sub structure works of bridges, Drain works &other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt
crushed graded coarse aggregates and fine aggregates as per relevant ISCodes machine mixed with super plasticisers, laid in layers, well compactedusing needle vibrators, providing weep holes wherever necessary, including
all lead & lifts, cost of all materials of quality, confirming to the requirementsof relevant IS codes, labour, Usage charges of machinery, curing and all other
appurtenances required to complete the work as per technical specifications 2 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesRC WALL
Septic tank
Soak pit
Baffel wall
| Cum | 8617.62 | 8617.62 | 15.35 | False | None | None | False | None | False | 132280.467 | 0 | 3497490 | 124924 | None | V-1P18ITM2.11 a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.
Raft
Slab
RC wall
| Tonne | 110837.22 | 110837.22 | 3.54 | False | None | None | False | None | False | 392363.7588 | 0 | 3497491 | 124924 | None | V-2P150ITM15.7 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis)
RC WALL
Inside wall
Septic tank
Soak pit
BOTTOM SLAB
Septic tank
Soak pit
| Sqm | 761.99 | 761.99 | 101.56 | False | None | None | False | None | False | 77387.7044 | 0 | 3497492 | 124924 | None | V-2P41ITM8.4.2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
Top slab
Septic tank
Soak pit
| Sqm | 386.57 | 386.57 | 20.56 | False | None | None | False | None | False | 7947.8792 | 0 | 3497493 | 124924 | None | V-2P41ITM8.3.1 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge.
Inside Wall
Septic tank
Soak pit
outer wall
Septic tank
Soak pit
| Sqm | 438.61 | 438.61 | 162.0 | False | None | None | False | None | False | 71054.82 | 0 | 3497494 | 124924 | None | XXIV18-19 SRXXIV (624) | C. I Manhole covers 24" x 24" | Nos | 2500.0 | 2500.0 | 4.0 | False | None | None | False | None | False | 10000.0 | 0 |
| 1720523219000 | 0 | None | None | Buildings | EXTERNAL ELECTRICAL WORKS | 1142127.78 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3497495 | 124925 | None | BSR-CDS-15 | MATERIAL :RCC dp structure using 9mtr rcc pole with WL145kg
| Set | 25215.4 | 25215.4 | 1.0 | False | None | None | False | None | False | 25215.4 | 0 | 3497496 | 124925 | None | BSR-CDS-15 | MATERIAL:11KV 45KN Polymeric insulators | No | 238.36 | 238.36 | 6.0 | False | None | None | False | None | False | 1430.16 | 0 | 3497497 | 124925 | None | BSR-CDS-15 | Guy Set Complete with No.15 Strain Insulator & Concreting materials | No | 1426.62 | 1426.62 | 2.0 | False | None | None | False | None | False | 2853.24 | 0 | 3497498 | 124925 | None | BSR-CDS-15 | Spiral earth electrodes | No | 292.64 | 292.64 | 2.0 | False | None | None | False | None | False | 585.28 | 0 | 3497499 | 124925 | None | BSR-CDS-15 | Caution/danger board | No | 172.28 | 172.28 | 1.0 | False | None | None | False | None | False | 172.28 | 0 | 3497500 | 124925 | None | BSR-CDS-15 | Anticlimbing device(12mts/1kg GI barbed wire) | Kg | 109.74 | 109.74 | 4.0 | False | None | None | False | None | False | 438.96 | 0 | 3497501 | 124925 | None | BSR | 11KV 400amps D/B GOS | Set | 24223.0 | 24223.0 | 1.0 | False | None | None | False | None | False | 24223.0 | 0 | 3497502 | 124925 | None | BSR | H frame for mounting gos | Set | 4878.12 | 4878.12 | 1.0 | False | None | None | False | None | False | 4878.12 | 0 | 3497503 | 124925 | None | BSR | 11 KV Lightning arrestors metal oxide 9kv 5kvA | Set | 1575.3 | 1575.3 | 1.0 | False | None | None | False | None | False | 1575.3 | 0 | 3497504 | 124925 | None | BSR | DOLO cutout(set/3Nos) | Set | 5720.64 | 5720.64 | 1.0 | False | None | None | False | None | False | 5720.64 | 0 | 3497505 | 124925 | None | BSR | LABOUR CHARGES:RCC dp structure using 9mtr rcc pole with WL145kg
| Set | 4854.52 | 4854.52 | 1.0 | False | None | None | False | None | False | 4854.52 | 0 | 3497506 | 124925 | None | BSR | LABOUR CHARGES:Guyset complete
| Set | 528.64 | 528.64 | 2.0 | False | None | None | False | None | False | 1057.28 | 0 | 3497507 | 124925 | None | BSR | LABOUR CHARGES:Spiral earth electrodes
| No | 82.6 | 82.6 | 2.0 | False | None | None | False | None | False | 165.2 | 0 | 3497508 | 124925 | None | BSR | LABOUR CHARGES:Guy concreting with Boulders, Mud and Sand
| No | 236.0 | 236.0 | 2.0 | False | None | None | False | None | False | 472.0 | 0 | 3497509 | 124925 | None | BSR | LABOUR CHARGES:Caution/danger board
| No | 71.98 | 71.98 | 1.0 | False | None | None | False | None | False | 71.98 | 0 | 3497510 | 124925 | None | BSR | LABOUR CHARGES:Anticlimbing device(12mts/1kg GI barbed wire)
| Kg | 37.76 | 37.76 | 4.0 | False | None | None | False | None | False | 151.04 | 0 | 3497511 | 124925 | None | BSR | LABOUR CHARGES:11KV 400amps D/B GOS
| Set | 1054.92 | 1054.92 | 1.0 | False | None | None | False | None | False | 1054.92 | 0 | 3497512 | 124925 | None | BSR | LABOUR CHARGES:H frame for mounting gos
| Set | 285.56 | 285.56 | 1.0 | False | None | None | False | None | False | 285.56 | 0 | 3497513 | 124925 | None | BSR | LABOUR CHARGES:11 KV Lightning arrestors metal oxide 9kv 5kvA
| Set | 106.2 | 106.2 | 1.0 | False | None | None | False | None | False | 106.2 | 0 | 3497514 | 124925 | None | BSR | LABOUR CHARGES:DOLO cutout(set/3Nos)
| Set | 210.04 | 210.04 | 1.0 | False | None | None | False | None | False | 210.04 | 0 | 3497515 | 124925 | None | BSR | MATERIAL PORTION:RCC pole 9mt Long with WL145kg
| No | 8440.54 | 8440.54 | 15.0 | False | None | None | False | None | False | 126608.1 | 0 | 3497516 | 124925 | None | BSR | MATERIAL PORTION:11kv Horizontal Cross Arm with clamps, HTST
supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL"
| Set | 788.24 | 788.24 | 15.0 | False | None | None | False | None | False | 11823.6 | 0 | 3497517 | 124925 | None | BSR | MATERIAL PORTION:11KV-5KN Polyclinic pin insulator(24mm dia FRP Rod)
| No | 260.78 | 260.78 | 45.0 | False | None | None | False | None | False | 11735.1 | 0 | 3497518 | 124925 | None | BSR | MATERIAL PORTION:11KV 45KN Polyclinic insulators
| No | 238.36 | 238.36 | 45.0 | False | None | None | False | None | False | 10726.2 | 0 | 3497519 | 124925 | None | BSR | MATERIAL PORTION: Guy Set Complete with No. 15 Strain Insulator & Concreting materials
| Set | 1426.62 | 1426.62 | 10.0 | False | None | None | False | None | False | 14266.2 | 0 | 3497520 | 124925 | None | BSR | MATERIAL PORTION:Rabbit ACSR conductor at 1.5% sag
| Km | 72587.7 | 72587.7 | 1.5 | False | None | None | False | None | False | 108881.55 | 0 | 3497521 | 124925 | None | BSR | MATERIAL PORTION:PG clamps for rabbit to rabbit conductors
| No | 136.88 | 136.88 | 30.0 | False | None | None | False | None | False | 4106.4 | 0 | 3497522 | 124925 | None | BSR | MATERIAL PORTION:Spiral earth electrodes
| No | 292.64 | 292.64 | 15.0 | False | None | None | False | None | False | 4389.6 | 0 | 3497523 | 124925 | None | BSR | MATERIAL PORTION:GI strips with GI wire laying (set/2Nos)
| Set | 338.66 | 338.66 | 8.0 | False | None | None | False | None | False | 2709.28 | 0 | 3497524 | 124925 | None | BSR | MATERIAL PORTION:Caution /danger board
| No | 172.28 | 172.28 | 5.0 | False | None | None | False | None | False | 861.4 | 0 | 3497525 | 124925 | None | BSR | MATERIAL PORTION:Anti climbing device (10mts/kg GI barbed wire)
| Kg | 109.74 | 109.74 | 15.0 | False | None | None | False | None | False | 1646.1 | 0 | 3497526 | 124925 | None | BSR | MATERIAL PORTION:Road cross Guardings with 4pin cross arms,Bolts&units
| Span | 3531.74 | 3531.74 | 10.0 | False | None | None | False | None | False | 35317.4 | 0 | 3497527 | 124925 | None | BSR | MATERIAL PORTION:Painting of 9m RCC poles with material and labour
| No | 826.0 | 826.0 | 15.0 | False | None | None | False | None | False | 12390.0 | 0 | 3497528 | 124925 | None | BSR | MATERIAL PORTION:Special 3pin cross arms with clamps braces bolt nuts and washers
| Set | 1431.34 | 1431.34 | 15.0 | False | None | None | False | None | False | 21470.1 | 0 | 3497529 | 124925 | None | BSR | LABOUR PORTION:Erection of RCC pole 9mt Long with WL145kg
| No | 1582.38 | 1582.38 | 15.0 | False | None | None | False | None | False | 23735.7 | 0 | 3497530 | 124925 | None | BSR | LABOUR PORTION
"Fixing of 11kv Horizontal Cross Arm with clamps, HTST
supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL"
| Set | 143.96 | 143.96 | 15.0 | False | None | None | False | None | False | 2159.4 | 0 | 3497531 | 124925 | None | BSR | LABOUR PORTION:Fixing of Guy Set Complete with No. 15 Strain Insulator & Concreting materials
| Set | 528.64 | 528.64 | 10.0 | False | None | None | False | None | False | 5286.4 | 0 | 3497532 | 124925 | None | BSR | LABOUR PORTION;Fixing of Rabbit ACSR conductor at 1.5% sag
| Km | 3892.82 | 3892.82 | 1.5 | False | None | None | False | None | False | 5839.23 | 0 | 3497533 | 124925 | None | BSR | LABOUR PORTION;Fixing of Spiral earth electrodes
| No | 82.6 | 82.6 | 15.0 | False | None | None | False | None | False | 1239.0 | 0 | 3497534 | 124925 | None | BSR | LABOUR PORTION:Fixing of GI strips with GI wire laying (set/2Nos)
| Set | 147.5 | 147.5 | 8.0 | False | None | None | False | None | False | 1180.0 | 0 | 3497535 | 124925 | None | BSR | LABOUR PORTION:Concreting materials for guysets without cement
| No | 236.0 | 236.0 | 10.0 | False | None | None | False | None | False | 2360.0 | 0 | 3497536 | 124925 | None | BSR | LABOUR PORTION:Fixing of Caution /danger board
| No | 71.98 | 71.98 | 5.0 | False | None | None | False | None | False | 359.9 | 0 | 3497537 | 124925 | None | BSR | LABOUR PORTION:Fixing of Anti climbing device (10mts/kg GI barbed wire)
| Kg | 37.76 | 37.76 | 15.0 | False | None | None | False | None | False | 566.4 | 0 | 3497538 | 124925 | None | BSR | LABOUR PORTION:Fixing of Road cross Guardings with 4pin cross arms,Bolts&units
| Span | 711.54 | 711.54 | 10.0 | False | None | None | False | None | False | 7115.4 | 0 | 3497539 | 124925 | None | BSR | LABOUR PORTION:Fixing of Special 3pin cross arms with clamps braces bolt nuts and washers
| Set | 116.82 | 116.82 | 15.0 | False | None | None | False | None | False | 1752.3 | 0 | 3497540 | 124925 | None | BSR | Concreting for 9mt rcc pole
a) base concrete 1:4:8 500x650x150mm
| No | 322.14 | 322.14 | 15.0 | False | None | None | False | None | False | 4832.1 | 0 | 3497541 | 124925 | None | BSR | Concreting for 9mt rcc pole
b) Pole concrete 1:2:4 650x500x1700mm
| No | 3726.44 | 3726.44 | 15.0 | False | None | None | False | None | False | 55896.6 | 0 | 3497542 | 124925 | None | BSR | Concreting for 9mt rcc pole
c) Coping with CC 1:2:4
| No | 639.56 | 639.56 | 15.0 | False | None | None | False | None | False | 9593.4 | 0 | 3497543 | 124925 | None | BSR | Erection of 3phase, 11Kv/433Volts,100KVA BEE -5star rated distribution Transformer centre using DPTS:9mts RCC DP Transformer structure using 9mtrs RCC poles | No | 38412.5 | 38412.5 | 1.0 | False | None | None | False | None | False | 38412.5 | 0 | 3497544 | 124925 | None | BSR | 11KV-5KN Polyclinic pin insulator(24mm dia FRP Rod) | No | 260.78 | 260.78 | 3.0 | False | None | None | False | None | False | 782.34 | 0 | 3497545 | 124925 | None | BSR | MATERIAL PORTION;11KV 45KN Polyclinic insulators
| No | 238.36 | 238.36 | 3.0 | False | None | None | False | None | False | 715.08 | 0 | 3497546 | 124925 | None | BSR | MATERIAL PORTION:Fixing of Guy Set Complete with No. 15 Strain Insulator & Concreting materials
| Set | 1426.62 | 1426.62 | 4.0 | False | None | None | False | None | False | 5706.48 | 0 | 3497547 | 124925 | None | BSR | MATERIAL PORTION:11KV/433V,63KVA,3 phase,50 cycles Distribution Transformer BEE-5star Rated with oil.
| No | 207983.0 | 207983.0 | 1.0 | False | None | None | False | None | False | 207983.0 | 0 | 3497548 | 124925 | None | BSR | Earthing materials pipe type for grounding
| Quintal | 2092.14 | 2092.14 | 3.0 | False | None | None | False | None | False | 6276.42 | 0 | 3497549 | 124925 | None | BSR | Caution /danger board | No | 172.28 | 172.28 | 1.0 | False | None | None | False | None | False | 172.28 | 0 | 3497550 | 124925 | None | BSR | Anti climbing device (10mts/kg GI barbed wire) | Kg | 109.74 | 109.74 | 2.0 | False | None | None | False | None | False | 219.48 | 0 | 3497551 | 124925 | None | BSR | Concreting materials for guysets without cement | No | 236.0 | 236.0 | 4.0 | False | None | None | False | None | False | 944.0 | 0 | 3497552 | 124925 | None | BSR | GI wire 8 SWG | Kg | 91.86 | 91.86 | 5.0 | False | None | None | False | None | False | 459.3 | 0 | 3497553 | 124925 | None | BSR | Gey wire 7/10 SWGG | Kg | 94.54 | 94.54 | 10.0 | False | None | None | False | None | False | 945.4 | 0 | 3497554 | 124925 | None | BSR | 11 KV Lightning arrestors metal oxide 9kv 5kvA | Set | 2048.48 | 2048.48 | 1.0 | False | None | None | False | None | False | 2048.48 | 0 | 3497555 | 124925 | None | BSR | LT Distribution Base for 100KVA with MCCB | No | 20703.1 | 20703.1 | 1.0 | False | None | None | False | None | False | 20703.1 | 0 | 3497556 | 124925 | None | BSR | LT wiring kit (from DTC to LT line through metering box and LT Distribution Board. | Kit | 8951.48 | 8951.48 | 1.0 | False | None | None | False | None | False | 8951.48 | 0 | 3497557 | 124925 | None | BSR | LT metering Box with CT's and necessary wiring for housing ETV meter | No | 6582.04 | 6582.04 | 1.0 | False | None | None | False | None | False | 6582.04 | 0 | 3497558 | 124925 | None | BSR | L.T Electronic Tri-vector meter5 , class0.5/1.0 accuracy. | No | 3908.16 | 3908.16 | 1.0 | False | None | None | False | None | False | 3908.16 | 0 | 3497559 | 124925 | None | BSR | 11KV solid core type H.G fuse (set/3nos) | Set | 1217.76 | 1217.76 | 1.0 | False | None | None | False | None | False | 1217.76 | 0 | 3497560 | 124925 | None | BSR | 11KV 200Amps Single break GOS | Set | 10767.5 | 10767.5 | 1.0 | False | None | None | False | None | False | 10767.5 | 0 | 3497561 | 124925 | None | BSR | MATERIAL PORTION:H frame for mounting GOS
| No | 3519.94 | 3519.94 | 1.0 | False | None | None | False | None | False | 3519.94 | 0 | 3497562 | 124925 | None | BSR | 9mts RCC DP Transformer structure using 9mtrs RCC poles | No | 6141.9 | 6141.9 | 1.0 | False | None | None | False | None | False | 6141.9 | 0 | 3497563 | 124925 | None | BSR | LABOUR PORTION
Fixing of Guy Set Complete with No. 15 Strain Insulator & Concreting materials
| Set | 528.64 | 528.64 | 4.0 | False | None | None | False | None | False | 2114.56 | 0 | 3497564 | 124925 | None | BSR | LABOUR PORTION
11KV/433V,63KVA,3 phase,50 cycles Distribution Transformer BEE-5star Rated with oil.
| No | 1018.34 | 1018.34 | 1.0 | False | None | None | False | None | False | 1018.34 | 0 | 3497565 | 124925 | None | BSR | LABOUR PORTION
Earthing materials pipe type for grounding
| Set | 855.5 | 855.5 | 3.0 | False | None | None | False | None | False | 2566.5 | 0 | 3497566 | 124925 | None | BSR | LABOUR PORTION
Caution /danger board
| No | 71.98 | 71.98 | 1.0 | False | None | None | False | None | False | 71.98 | 0 | 3497567 | 124925 | None | BSR | LABOUR PORTION
Anti climbing device (10mts/kg GI barbed wire)
| Kg | 37.76 | 37.76 | 2.0 | False | None | None | False | None | False | 75.52 | 0 | 3497568 | 124925 | None | BSR | LABOUR PORTION
11 KV Lightning arrestors metal oxide 9kv 5kvA
| Set | 106.2 | 106.2 | 1.0 | False | None | None | False | None | False | 106.2 | 0 | 3497569 | 124925 | None | BSR | LABOUR PORTION
LT wiring kit (from DTC to LT line through metering box and LT Distribution Board.
| Kit | 848.42 | 848.42 | 2.0 | False | None | None | False | None | False | 1696.84 | 0 | 3497570 | 124925 | None | BSR | LABOUR PORTION
LT metering Box with CT's and necessary wiring for housing ETV meter
| No | 767.0 | 767.0 | 1.0 | False | None | None | False | None | False | 767.0 | 0 | 3497571 | 124925 | None | BSR | LABOUR PORTION
L.T Electronic Tri-vector meter5 , class0.5/1.0 accuracy.
| No | 941.64 | 941.64 | 1.0 | False | None | None | False | None | False | 941.64 | 0 | 3497572 | 124925 | None | BSR | LABOUR PORTION
11KV solid core type H.G fuse (set/3nos)
| Set | 210.04 | 210.04 | 1.0 | False | None | None | False | None | False | 210.04 | 0 | 3497573 | 124925 | None | BSR | LABOUR PORTION
11KV 200Amps Single break GOS
| Set | 949.9 | 949.9 | 1.0 | False | None | None | False | None | False | 949.9 | 0 | 3497574 | 124925 | None | BSR | LABOUR PORTION
H frame for mounting GOS
| No | 225.38 | 225.38 | 1.0 | False | None | None | False | None | False | 225.38 | 0 | 3497575 | 124925 | None | BSR | Concreting for 9mt rcc pole
a) base concrete 1:4:8 500x650x150mm
| No | 279.66 | 279.66 | 2.0 | False | None | None | False | None | False | 559.32 | 0 | 3497576 | 124925 | None | BSR | Concreting for 9mt rcc pole
b) Pole concrete 1:2:4 650x500x1700mm
| No | 3240.28 | 3240.28 | 2.0 | False | None | None | False | None | False | 6480.56 | 0 | 3497577 | 124925 | None | BSR | Concreting for 9mt rcc pole
c) Coping with CC 1:2:4
| No | 555.78 | 555.78 | 2.0 | False | None | None | False | None | False | 1111.56 | 0 | 3497578 | 124925 | None | BSR | 11kv class 3cx95sqmmxLPE ug cable (2run) | Km | 1316426.0 | 1316426.0 | 0.02 | False | None | None | False | None | False | 26328.52 | 0 | 3497579 | 124925 | None | BSR | Cable termination kit Indoor HS type suitable for above cable | Kit | 4679.88 | 4679.88 | 2.0 | False | None | None | False | None | False | 9359.76 | 0 | 3497580 | 124925 | None | BSR | Cable termination kit Indoor HS type suitable for above cable | Kit | 4308.18 | 4308.18 | 4.0 | False | None | None | False | None | False | 17232.72 | 0 | 3497581 | 124925 | None | BSR | Cable covering tiles 250x125x40mm | No | 11.8 | 11.8 | 200.0 | False | None | None | False | None | False | 2360.0 | 0 | 3497582 | 124925 | None | BSR | Sand | Sqm | 2006.0 | 2006.0 | 5.0 | False | None | None | False | None | False | 10030.0 | 0 | 3497583 | 124925 | None | BSR | Rcc hume pipes 2000mm long 150mm dia | No | 354.0 | 354.0 | 4.0 | False | None | None | False | None | False | 1416.0 | 0 | 3497584 | 124925 | None | BSR | Collars for rcc hume pipes | No | 94.4 | 94.4 | 2.0 | False | None | None | False | None | False | 188.8 | 0 | 3497585 | 124925 | None | BSR | GI pipe 100mm dia for cable raising drain crossing | Mtr | 1803.04 | 1803.04 | 2.0 | False | None | None | False | None | False | 3606.08 | 0 | 3497586 | 124925 | None | BSR | Route and joint indicating stones | No | 153.4 | 153.4 | 2.0 | False | None | None | False | None | False | 306.8 | 0 | 3497587 | 124925 | None | BSR | LABOUR PORTION
11kv class 3cx95sqmmxLPE ug cable (2run)
| Mtr | 53.43 | 53.43 | 20.0 | False | None | None | False | None | False | 1068.6 | 0 | 3497588 | 124925 | None | BSR | Cable termination kit outdoor HS type suitable for above cable | Kit | 2318.7 | 2318.7 | 6.0 | False | None | None | False | None | False | 13912.2 | 0 | 3497589 | 124925 | None | BSR | Rcc hume pipes 2000mm long 150mm dia | No | 60.18 | 60.18 | 4.0 | False | None | None | False | None | False | 240.72 | 0 | 3497590 | 124925 | None | BSR | GI pipe 100mm dia for cable raising drain crossing | Mtr | 68.44 | 68.44 | 2.0 | False | None | None | False | None | False | 136.88 | 0 | 3497591 | 124925 | None | BSR | Route and joint indicating stones | No | 101.48 | 101.48 | 2.0 | False | None | None | False | None | False | 202.96 | 0 | 3497592 | 124925 | None | BSR | Cable trench excavation 1000x0.6x1mt in ordinary soil | Cum | 266.68 | 266.68 | 10.0 | False | None | None | False | None | False | 2666.8 | 0 | 3497593 | 124925 | None | BSR | Refilling and consolidation | Cum | 59.0 | 59.0 | 10.0 | False | None | None | False | None | False | 590.0 | 0 | 3497594 | 124925 | None | BSR | Covering the cable with tiles | Km | 3378.34 | 3378.34 | 0.01 | False | None | None | False | None | False | 33.7834 | 0 | 3497595 | 124925 | None | BSR | Spreading sand and forming with sand around the cable | Km | 11872.0 | 11872.0 | 0.25 | False | None | None | False | None | False | 2968.0 | 0 | 3497596 | 124925 | None | BSR | PART E- Providing Chain link Fencing to HT Yard
Providing chain lin fencing 50mm size of 8gauge properly stretched between rectangular pole and fixed with suitable bolts and nuts the free end shall be welded to the pole and block pipe at top and bottom as required including cost of all materilas labour lead and lifts cutting bending wherever necessary wastage and lapping et complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint
| Sqm | 1164.66 | 1164.66 | 120.0 | False | None | None | False | None | False | 139759.2 | 0 |
| 1720523219000 | 0 | None | None | Buildings | DESIGN CONSULTANCY CHARGES | 400000.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3497597 | 124926 | None | DATA RATE | The Tenderer (agency) should arrange to obtain (get), detailed Architecturaldrawings and elevations, Structural designs and drawings including Soil exploration & proofchecking by IISC /IIT/NIT/any Engineering college only as decided by the Department and the same has to be furnished to the Department for approval and providing consultancy for Architectural designs & drawings, elevation, 3D view, Internal and External Electrical services including electrical infrastructure , Lifts, CCTV/Net working system interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project (This item is included in schedule B as a item) and 6 sets of as built drawings should be submitted to the employer. The Consultancy Fees which is included as an item in schedule B shall be paid on prorate basis of the main work or by negotiation with the employer. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge