tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1720517945000 | 1 | None | None | Buildings | Construction of Samuday Bhavan | 969477.13 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3496189 | 124850 | None | code01 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 470.0 | 470.0 | 34.15 | False | None | None | False | None | False | 16050.5 | 0 | 3496190 | 124850 | None | code02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 5554.0 | 5554.0 | 14.63 | False | None | None | False | None | False | 81255.02 | 0 | 3496191 | 124850 | None | code03 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 4750.0 | 4750.0 | 6.5 | False | None | None | False | None | False | 30875.0 | 0 | 3496192 | 124850 | None | code04 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 5352.0 | 5352.0 | 4.88 | False | None | None | False | None | False | 26117.76 | 0 | 3496193 | 124850 | None | code05 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 199.0 | 199.0 | 25.4 | False | None | None | False | None | False | 5054.6 | 0 | 3496194 | 124850 | None | code06 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 7178.4 | 7178.4 | 2.07 | False | None | None | False | None | False | 14859.288 | 0 | 3496195 | 124850 | None | code07 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 204.0 | 204.0 | 20.25 | False | None | None | False | None | False | 4131.0 | 0 | 3496196 | 124850 | None | code08 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 6457.32 | 6457.32 | 3.04 | False | None | None | False | None | False | 19630.2528 | 0 | 3496197 | 124850 | None | code09 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 6576.9 | 6576.9 | 0.92 | False | None | None | False | None | False | 6050.748 | 0 | 3496198 | 124850 | None | code10 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 6580.2 | 6580.2 | 1.84 | False | None | None | False | None | False | 12107.568 | 0 | 3496199 | 124850 | None | code11 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 7423.2 | 7423.2 | 12.04 | False | None | None | False | None | False | 89375.328 | 0 | 3496200 | 124850 | None | code12 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Kg | 96.0 | 96.0 | 1686.56 | False | None | None | False | None | False | 161909.76 | 0 | 3496201 | 124850 | None | code13 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 6696.0 | 6696.0 | 24.03 | False | None | None | False | None | False | 160904.88 | 0 | 3496202 | 124850 | None | code14 | Providing & fixing of 2-track x 2panel sliding windows made out of multi chambered UPVC (Matching to RAL9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with G reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8+-0.2 mm. Maximum possible size 1519mm 1519mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 5842.0 | 5842.0 | 5.76 | False | None | None | False | None | False | 33649.92 | 0 | 3496203 | 124850 | None | code15 | Providing and fixing M.S. grills of required pattern in frames of win dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Kg | 143.0 | 143.0 | 120.96 | False | None | None | False | None | False | 17297.28 | 0 | 3496204 | 124850 | None | code16 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 276.0 | 276.0 | 338.62 | False | None | None | False | None | False | 93459.12 | 0 | 3496205 | 124850 | None | code17 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye,
River Pink or equivalent. with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 1888.0 | 1888.0 | 64.35 | False | None | None | False | None | False | 121492.8 | 0 | 3496206 | 124850 | None | code18 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 118.0 | 118.0 | 138.72 | False | None | None | False | None | False | 16368.96 | 0 | 3496207 | 124850 | None | code19 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 118.0 | 118.0 | 122.39 | False | None | None | False | None | False | 14442.02 | 0 | 3496208 | 124850 | None | code20 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 83.0 | 83.0 | 261.11 | False | None | None | False | None | False | 21672.13 | 0 | 3496209 | 124850 | None | code21 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Nos | 1481.0 | 1481.0 | 2.0 | False | None | None | False | None | False | 2962.0 | 0 | 3496210 | 124850 | None | code22 | Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 3860.0 | 3860.0 | 4.62 | False | None | None | False | None | False | 17833.2 | 0 | 3496211 | 124850 | None | code23 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Nos | 82.0 | 82.0 | 2.0 | False | None | None | False | None | False | 164.0 | 0 | 3496212 | 124850 | None | code24 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Nos | 111.0 | 111.0 | 2.0 | False | None | None | False | None | False | 222.0 | 0 | 3496213 | 124850 | None | code25 | Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Nos | 621.0 | 621.0 | 2.0 | False | None | None | False | None | False | 1242.0 | 0 | 3496214 | 124850 | None | code26 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Nos | 175.0 | 175.0 | 2.0 | False | None | None | False | None | False | 350.0 | 0 |
| 1720517945000 | 0 | None | None | Buildings | ELECTRIFICATION | 39943.28 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3496215 | 124851 | None | code01 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box,elbows, screws at an interval of 300mm …. etc. as required. with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. 20 mm | Mtr | 22.0 | 22.0 | 10.0 | False | None | None | False | None | False | 220.0 | 0 | 3496216 | 124851 | None | code02 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box,elbows, screws at an interval of 300mm …. etc. as required. with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. 25 mm | Mtr | 24.0 | 24.0 | 5.0 | False | None | None | False | None | False | 120.0 | 0 | 3496217 | 124851 | None | code03 | Point wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. Short point upto 3Mtr from tapping point to out let via switch | Point | 200.0 | 200.0 | 6.0 | False | None | None | False | None | False | 1200.0 | 0 | 3496218 | 124851 | None | code04 | Point wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch | Point | 275.0 | 275.0 | 2.0 | False | None | None | False | None | False | 550.0 | 0 | 3496219 | 124851 | None | code05 | Point wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch | Point | 400.0 | 400.0 | 2.0 | False | None | None | False | None | False | 800.0 | 0 | 3496220 | 124851 | None | code06 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. 1.5 sqmm | Mtr | 20.5 | 20.5 | 120.0 | False | None | None | False | None | False | 2460.0 | 0 | 3496221 | 124851 | None | code07 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. 2.5 sqmm | Mtr | 32.0 | 32.0 | 200.0 | False | None | None | False | None | False | 6400.0 | 0 | 3496222 | 124851 | None | code08 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. 4 sqmm | Mtr | 45.0 | 45.0 | 100.0 | False | None | None | False | None | False | 4500.0 | 0 | 3496223 | 124851 | None | code09 | Supplying 6A flush type socket and 6 Amps flush type SP switch either surface/flush mounting in existing gang box in 4 mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work 6 Amps 3/5 Way | Each | 132.0 | 132.0 | 5.0 | False | None | None | False | None | False | 660.0 | 0 | 3496224 | 124851 | None | code10 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wal with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work 1-3Way | Each | 95.0 | 95.0 | 2.0 | False | None | None | False | None | False | 190.0 | 0 | 3496225 | 124851 | None | code11 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wal with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work 4-5Way | Each | 105.0 | 105.0 | 2.0 | False | None | None | False | None | False | 210.0 | 0 | 3496226 | 124851 | None | code12 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wal with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work 6 Way | Each | 125.0 | 125.0 | 3.0 | False | None | None | False | None | False | 375.0 | 0 | 3496227 | 124851 | None | code13 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work Stepped Fan Regulator | Each | 290.0 | 290.0 | 2.0 | False | None | None | False | None | False | 580.0 | 0 | 3496228 | 124851 | None | code14 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work 16Amps one way switch | Each | 115.0 | 115.0 | 1.0 | False | None | None | False | None | False | 115.0 | 0 | 3496229 | 124851 | None | code15 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work 6 Amps Bell Push | Each | 96.0 | 96.0 | 1.0 | False | None | None | False | None | False | 96.0 | 0 | 3496230 | 124851 | None | code16 | Supplying and fixing / replacing of 6/16/32 Amps electricals accessories on existing switch board with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work 6 Amps Backelite ceiling rose | No | 58.0 | 58.0 | 5.0 | False | None | None | False | None | False | 290.0 | 0 | 3496231 | 124851 | None | code17 | Supplying and fixing / replacing of 6/16/32 Amps electricals accessories on existing switch board with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work 6 Amps lamp holder | No | 58.0 | 58.0 | 5.0 | False | None | None | False | None | False | 290.0 | 0 | 3496232 | 124851 | None | code18 | Supplying and fixing / replacing of 6/16/32 Amps electricals accessories on existing switch board with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work 6 Amps bell buzzer | No | 114.0 | 114.0 | 1.0 | False | None | None | False | None | False | 114.0 | 0 | 3496233 | 124851 | None | code19 | Suppling of TPST with rewirabel porclain channels in SM enclosure. Made out of 14 SWG Powder coated paint approved colour with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work 32 Amps | Each | 1800.0 | 1800.0 | 1.0 | False | None | None | False | None | False | 1800.0 | 0 | 3496234 | 124851 | None | code20 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered iverted wooden plugs screws with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work 8"x6"x1.5" | Each | 70.0 | 70.0 | 1.0 | False | None | None | False | None | False | 70.0 | 0 | 3496235 | 124851 | None | code21 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered iverted wooden plugs screws with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work 10"x8"x1.5" | Each | 90.0 | 90.0 | 1.0 | False | None | None | False | None | False | 90.0 | 0 | 3496236 | 124851 | None | code22 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered iverted wooden plugs screws with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work 20"x20"x2.5" | Each | 292.0 | 292.0 | 1.0 | False | None | None | False | None | False | 292.0 | 0 | 3496237 | 124851 | None | code23 | Supplying & fixing of Porcelain fuse channel with cut out
on existing wooden/panel using necessary nuts, bolts and washers with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work 32 Amps | Each | 174.0 | 174.0 | 1.0 | False | None | None | False | None | False | 174.0 | 0 | 3496238 | 124851 | None | code24 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood / panel board using necessary phase separators, handle and wiring complete. Protection of Overload and Short Circuit with thermal Magnetic/Micro processor and Earth Fault as per IS-13947 (Icu=Ics) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work 100 Amps 25 kA | Each | 6400.0 | 6400.0 | 1.0 | False | None | None | False | None | False | 6400.0 | 0 | 3496239 | 124851 | None | code25 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work 6-32 Amps SP | Each | 434.0 | 434.0 | 5.0 | False | None | None | False | None | False | 2170.0 | 0 | 3496240 | 124851 | None | code26 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work I-Single Door 4 Way SP & N | Each | 777.0 | 777.0 | 1.0 | False | None | None | False | None | False | 777.0 | 0 | 3496241 | 124851 | None | code27 | Supplying fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 Amps three phase 4 wire whole current class-1 Accuracy Energy Meter with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work | Each | 4745.0 | 4745.0 | 1.0 | False | None | None | False | None | False | 4745.0 | 0 | 3496242 | 124851 | None | code28 | L.T.U.G. CABLES : Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts,
washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work | No | 2999.7 | 2999.7 | 1.0 | False | None | None | False | None | False | 2999.7 | 0 | 3496243 | 124851 | None | code29 | INSULATED CABLE ON MESSENGER WIRE : Using 2 single core wires for a single phase and 4 single core wires for 3 phase. Supplying and stringing PVC insulated and PVC sheathed 650/1100 V Class aluminium conductor of size supported by 3.15 mm (10 SWG) GI messenger wire with two break insulators, one at each end of the span with suspenders at intervals of 0.75 m. Each suspender shall be of porcelain reel insulator of suitable core through which insulated wire passes (single core or twin core as the case may be) and this reel insulator shall be fixed to the messenger wire using 2 mm (No. 14SWG) GI wire suitably bent and twisted. Seperate reel insulator shall be provided for each wire, the messenger wire shall be bed-ended on the clamp provided to the departmental pole wide item No. 4 above with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work Single Phase using 2 wire b) 6 Sqmm | Rmtr | 47.48 | 47.48 | 15.0 | False | None | None | False | None | False | 712.2 | 0 | 3496244 | 124851 | None | code30 | SHORT POLES : (Where clearance between Messenger wire and gound is inadequate) a) Supplying and fixing 40 mm dia 2.90 thick GI pipe 1.8m long complete with atleast 12 GI pipe 1.8m, long complete with atleast 2 Nos of through bolts 12 mm dia with MS back plate 100x100x6 mm dia with eye bolt fixed at top deadending messenger wire with masonry patch work etc., complete as per approved drawing (for single phase installations) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work | Each | 543.38 | 543.38 | 1.0 | False | None | None | False | None | False | 543.38 | 0 |
|
|
---|