createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1720529454104
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd32000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose18-07-2024 16:30:00
tenderQueryClose16-07-2024 16:30:00
technicalBidOpenNone
publishedDate09-07-2024 20:17:18
publishedByPostRWSSD_EE_DIV_RCR
publishedByUserKPE10084 - VINOD KUMAR GUPTA
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonBasavaraju AE
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9743813881
tenderSupplierListNone
tenderSchedule
createdTs1720529454144
version4
createdDateNone
modifiedDateNone
tenderNumberRWSSD/2024-25/WT/WORK_INDENT8238
titleConstruction of RO Plant at Pandurang Camp in Maski Constituency of Sindhnaur Taluka of Raichur District
descriptionConstruction of RO Plant at Pandurang Camp in Maski Constituency of Sindhnaur Taluka of Raichur District
categoryWORKS
categoryTextWorks
ecv1264332.91
deptNameRural Drinking Water and Sanitation Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location1280
locationNameRWSSD Division Office Raichur
provisionalAmount1500000.0
groupOverheadTotalNone
fileNumberRDWSSD/2023-24/RCR/KKRDB/WPP11
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17205294540000NoneNoneWater /sewage treatment tanksConstruction of RO Plant at Pandurang Camp in Maski Constituency of Sindhnaur Taluka of Raichur District1264332.91
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3499684125027Nonecode01Construction of RO Plant at Pandurang Camp in Maski Constituency of Sindhnaur Taluka of Raichur District :- PUMPING MACHINERY :-Providing, supplying to work site, fixing of Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034 3Phase, SS Bowl & Impeller with Low volt Motor and as per specifications, with testing, as per instructions of engineer incharge of work and latest amendmnents 5.00 HP - 300 LPM @ 39 m = 3 STG Outlet Dia - 2.50” etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of workEach26874.026874.01.0FalseNoneNoneFalseNoneFalse26874.00
3499685125027Nonecode02Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x2.5 m2 etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of workMtr89.2589.2515.0FalseNoneNoneFalseNoneFalse1338.750
3499686125027Nonecode03Supply and delivery at site of brand new best make pressure gauge bourdon type as per IS 778/1984 with ISI Mark and as per its latest amendments.Size 63 mm etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of workEach436.8436.81.0FalseNoneNoneFalseNoneFalse436.80
3499687125027Nonecode04Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 65 mm etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of workEach1522.51522.51.0FalseNoneNoneFalseNoneFalse1522.50
3499688125027Nonecode05Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 65 mm etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of workEach1627.51627.51.0FalseNoneNoneFalseNoneFalse1627.50
3499689125027Nonecode06Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box. etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of workEach1207.51207.51.0FalseNoneNoneFalseNoneFalse1207.50
3499690125027Nonecode07the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOLDirect Online Starter 2) S-D- Star Delta Starter Upto 6 HP pumps etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of workEach10027.510027.51.0FalseNoneNoneFalseNoneFalse10027.50
3499691125027Nonecode08Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets. etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of workEach577.5577.51.0FalseNoneNoneFalseNoneFalse577.50
3499692125027Nonecode09Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring, freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of workMtr577.5577.530.0FalseNoneNoneFalseNoneFalse17325.00
3499693125027Nonecode10Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of workJob1417.51417.51.0FalseNoneNoneFalseNoneFalse1417.50
3499694125027Nonecode11Providing main connection from pole PVC insulated sheathed steel wire cable in new trench as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit 3.5 x 10 sqmm etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of workMtr141.75141.7515.0FalseNoneNoneFalseNoneFalse2126.250
3499695125027Nonecode12CONSTRUCTION OF ROOM : Earth work excavation by manual means for drains,canals, waste weir,draft, approach channels, key trenches, foundation of bridges andsuch simillar works in all kinds of soils , as per drawing and technicalspecifications, including setting out, shoring, strutting, barricading,caution lights, removal of stumps and other deleterious matter,excavated surface leveled and sides neatly dressed disposing off theexcavated stuff or sorting & stacking the selected stuff for reuse in aradius of 50 m and lift upto 1.5 m including cost of labour, tools & otherappurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of workCum254.1254.118.32FalseNoneNoneFalseNoneFalse4655.1120
3499696125027Nonecode13Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately).Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of workCum5947.25947.23.76FalseNoneNoneFalseNoneFalse22361.4720
3499697125027Nonecode14Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of workCum5891.555891.554.78FalseNoneNoneFalseNoneFalse28161.6090
3499698125027Nonecode15Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of workCum6948.96948.92.26FalseNoneNoneFalseNoneFalse15704.5140
3499699125027Nonecode16Providing and laying in position Reinforced cement concrete for all Foundation works.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of workCum12256.0512256.058.1FalseNoneNoneFalseNoneFalse99274.0050
3499700125027Nonecode17Providing Thermo-Mechanically Treated bars of grade Fe-500D ormore Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including costof material, labour, usage charges complete as per specifications.(Thelaps and wastages shall not be measured separately) etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of workMT93929.8593929.850.891FalseNoneNoneFalseNoneFalse83691.496350
3499701125027Nonecode18Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of workSqm1375.51375.554.17FalseNoneNoneFalseNoneFalse74510.8350
3499702125027Nonecode19Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding.20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of workCum279.3279.317.11FalseNoneNoneFalseNoneFalse4778.8230
3499703125027Nonecode20Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of workSqm371.7371.7116.48FalseNoneNoneFalseNoneFalse43295.6160
3499704125027Nonecode21Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of workSqm933.45933.4519.25FalseNoneNoneFalseNoneFalse17968.91250
3499705125027Nonecode22Finishing walls with water proofing cement paint of required shade :Old work (one coats applied @ 2.20 kg/10 m²) over priming coat of primer applied @ 0.80 litrs/10 m² complete including cost of Priming coat including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of workSqm91.3591.35116.48FalseNoneNoneFalseNoneFalse10640.4480
3499706125027Nonecode23Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly.cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of workcm4.24.25500.0FalseNoneNoneFalseNoneFalse23100.00
3499707125027Nonecode24Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of workSqm2764.652764.653.78FalseNoneNoneFalseNoneFalse10450.3770
3499708125027Nonecode25Supplying Heavy Guage PVC Conduit pipe 19/20 Dia 2mm thick confirming to IS 2509 with suitable size bends metal /PVC junction boxes ,adhesive paste etc.., and running before concreting the slab.The conduite should be tied to the before reinforcement rods by using binding wires & unused ways of junction boxes and pipe ends should be covered using PVC end enclousees,run with 18SWG GI fishes wire wherever necessary etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of workMtr69.069.015.0FalseNoneNoneFalseNoneFalse1035.00
3499709125027Nonecode26Wiring for lighting/Power circute using one of FRLS PVC insulated 1100V Grade Multi Starded copper with low conducter Resistence single core wire is open or concealed system of wiring with Specified IS -694:1990 and Confirming to GTP of Group A 4 sqmm etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of workMtr63.063.015.0FalseNoneNoneFalseNoneFalse945.00
3499710125027Nonecode27Supplying & adopting Loop System of in Existing PVC Conductor/Casing ,Caping Using 1100 V Grade copper conductor Flexible multi strand FRLS PVC insulated 2x1 Sqmm able with low conducter Resistence single core wire is open or concealed system of wiring Confirming to GTP without swich the ohter end of wire shall be terminted with sufficent Loose length in a wood /PVC Round Block complete for Each outlet Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of workPoint394.0394.02.0FalseNoneNoneFalseNoneFalse788.00
3499711125027Nonecode28Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6Amps 3/5 Way etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of workPoint103.0103.02.0FalseNoneNoneFalseNoneFalse206.00
3499712125027Nonecode29Supplying & Fixing Superior Quality modular switch mounting poly corbonate plate with Necessary supporying Backplate with Required Nos of Machine Screws Bolts ,Nuts Etc., Complete on the Existing Metal /PVC Box 4 module etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of workPoint175.0175.04.0FalseNoneNoneFalseNoneFalse700.00
3499713125027Nonecode30Supplying & fixing of retrofit type LED bulb W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater 70 greater than efficacy greater than 80 lumen per W, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should lesser than 5 percentage of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20 percentage, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical conditionEach425.0425.02.0FalseNoneNoneFalseNoneFalse850.00
3499714125027Nonecode31Supplying& Fixing miniture circute breaker Existing MCB distribution Board using necessary fixing Material & C Type curve Indictor ON/OFF Energy cross-3 with short circute breaking capacity of 10K & complete wiring as required confirming IEC 60898 40-63Amps TPN etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of workEach3044.03044.01.0FalseNoneNoneFalseNoneFalse3044.00
3499715125027Nonecode32GESCOM Deposite Charges for RR NO.No9460.09460.01.0FalseNoneNoneFalseNoneFalse9460.00
3499716125027Nonecode33Supplying & Fixing Ceiling Fan etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of workNo2677.02677.01.0FalseNoneNoneFalseNoneFalse2677.00
3499717125027Nonecode34500 LPH PURE DRINKING WATER PLANT (RO, UF+UV) FRP SKID TYPE :Water purification plants: Supplying, Installation and Commissioning of automatic Water purification plant (RO+UF) with all accessories piping,product water tank on single phase power supply as per the encloseddetailed Technical Specifications including cost of material, loadingand unloading and as directed by the Engineer in charge. (Ref- detailed specification enclosed seperatly). Note:- 1.The above rates mentioned are only for the preparation of estimate purpose. 2. All items are to be of BSI /NFS standards,with BSI / NFS mark . 3. Tenders to beinvited for procurement. 4. No direct payment should be made under any situation or condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge. Note : Refer the ANNEXURE : F for Detailed Specification of Each components etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of workNo322350.0322350.01.0FalseNoneNoneFalseNoneFalse322350.00
3499718125027Nonecode35PIPELINE : Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50mCum508.2508.2299.7FalseNoneNoneFalseNoneFalse152307.540
3499719125027Nonecode36Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be usedetc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of work HDPE Grade PE100-PN6.0,110mm diaMtr432.6432.6490.0FalseNoneNoneFalseNoneFalse211974.00
3499720125027Nonecode37Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, layingtrue to line, level and perfect linking at joints leak proof includingjointing of approved type with all labour charges and all lift charges,handling charges including encasing the pipe around to a depth not lessthan 15 cms with gravel or selected earth available from the excavationetc. complete. PVC pipes 25mm dia, 10 kg/sqcm & class 5 etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of workMtr70.3570.3565.0FalseNoneNoneFalseNoneFalse4572.750
3499721125027Nonecode38Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of workCum168.0168.0299.7FalseNoneNoneFalseNoneFalse50349.60
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17205294550000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17205294550000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17205294550000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17205294550000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17205294550000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17205294550000NoneNoneELIGIBILITYDepartment Registration DetailsNone
17205294550000NoneNoneELIGIBILITYTotal value of civl engineering works executed and payments received in the last five years (year-wise)None
17205294550000NoneNoneELIGIBILITYList of existing commitments and ongoing workNone
17205294550000NoneNoneELIGIBILITYList of works for which tenders already submittedNone
17205294550000NoneNoneELIGIBILITYBanker DetailsNone
17205294630000NoneNoneELIGIBILITYThe Employer reserves the right to reject any or all Tenders without assigning any reason.None
17205294680000NoneNoneELIGIBILITYThe Department is not responsible for any delay in accessing KPPP portal.None
17205294750000NoneNoneELIGIBILITYIt is to be noted that any false documentation is found to be uploaded, the action may attract punitive measures such as blacklisting, cancellation of registration etc.,None
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Contractor Registration CertificateTrueTechnical Bid
Annual Turnover Certificate by CA for Five years for 2018-19 to 2022-23 along with UDIN NumberTrueTechnical Bid
Similar nature WPP Work Done Certificate of 50 percentage of Amount put to tenderTrueTechnical Bid
PAN & GST Registration CertificateTrueTechnical Bid
Income Tax Returns/Filed copiesTrueTechnical Bid
Assessed bid capacity as per Bid DocumentTrueTechnical Bid
Accurate postal address, Principal place of address, Mobil Number and email address Pan No, Tin No, should be mentioned clearlyTrueTechnical Bid
List of existing commitments and ongoing worksTrueTechnical Bid
List of works for which tenders already submittedTrueTechnical Bid
Tie Up Agreement with WPP Manufacturer or SupplierTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone