1720521115000 | 0 | None | None | Water supply/sewage lines | Construction of RO Plant at Komnur village in Lingasugur Taluka of Raichur District | 1264315.19 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3496664 | 124883 | None | code01 | Construction of RO Plant at Komnur village in Lingasugur Taluka of Raichur District :- DRILLING OF BORE WELL :- Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour for 0.00 Mtr to 50 Mtr. etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of work | Mtr | 388.5 | 388.5 | 100.0 | False | None | None | False | None | False | 38850.0 | 0 | 3496665 | 124883 | None | code02 | do-50.00 Mtr to 100 Mtr. etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of work | Mtr | 487.2 | 487.2 | 100.0 | False | None | None | False | None | False | 48720.0 | 0 | 3496666 | 124883 | None | code03 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. PVC pipes of 06 Kg/cm2 for 160mm etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of work | Mtr | 648.9 | 648.9 | 15.0 | False | None | None | False | None | False | 9733.5 | 0 | 3496667 | 124883 | None | code04 | PUMPING MACHINERY :-Providing, supplying to work site, fixing of Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034 3Phase, SS Bowl & Impeller with Low volt Motor and as per specifications, with testing, as per instructions of engineer incharge of work and latest amendmnents 5.00 HP - 300 LPM @ 39 m = 3 STG Outlet Dia - 2.50” etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of work | Each | 26874.0 | 26874.0 | 1.0 | False | None | None | False | None | False | 26874.0 | 0 | 3496668 | 124883 | None | code05 | Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x2.5 m2 etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of work | Mtr | 89.25 | 89.25 | 30.0 | False | None | None | False | None | False | 2677.5 | 0 | 3496669 | 124883 | None | code06 | Supply and delivery at site of brand new best make pressure gauge bourdon type as per IS 778/1984 with ISI Mark and as per its latest amendments.Size 63 mm etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of work | Each | 436.8 | 436.8 | 1.0 | False | None | None | False | None | False | 436.8 | 0 | 3496670 | 124883 | None | code07 | Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 65 mm etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of work | Each | 1522.5 | 1522.5 | 1.0 | False | None | None | False | None | False | 1522.5 | 0 | 3496671 | 124883 | None | code08 | Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 65 mm etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of work | Each | 1627.5 | 1627.5 | 1.0 | False | None | None | False | None | False | 1627.5 | 0 | 3496672 | 124883 | None | code09 | Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box. etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of work | Each | 1207.5 | 1207.5 | 1.0 | False | None | None | False | None | False | 1207.5 | 0 | 3496673 | 124883 | None | code10 | the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOLDirect Online Starter 2) S-D- Star Delta Starter Upto 6 HP pumps etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of work | Each | 10027.5 | 10027.5 | 1.0 | False | None | None | False | None | False | 10027.5 | 0 | 3496674 | 124883 | None | code11 | Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets. etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of work | Each | 577.5 | 577.5 | 1.0 | False | None | None | False | None | False | 577.5 | 0 | 3496675 | 124883 | None | code12 | Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring, freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of work | Mtr | 577.5 | 577.5 | 30.0 | False | None | None | False | None | False | 17325.0 | 0 | 3496676 | 124883 | None | code13 | Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of work | Job | 1417.5 | 1417.5 | 1.0 | False | None | None | False | None | False | 1417.5 | 0 | 3496677 | 124883 | None | code14 | Providing main connection from pole PVC insulated sheathed steel wire cable in new trench as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit 3.5 x 10 sqmm etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of work | Mtr | 141.75 | 141.75 | 20.0 | False | None | None | False | None | False | 2835.0 | 0 | 3496678 | 124883 | None | code15 | CONSTRUCTION OF ROOM : Earth work excavation by manual means for drains,canals, waste weir,draft, approach channels, key trenches, foundation of bridges andsuch simillar works in all kinds of soils , as per drawing and technicalspecifications, including setting out, shoring, strutting, barricading,caution lights, removal of stumps and other deleterious matter,excavated surface leveled and sides neatly dressed disposing off theexcavated stuff or sorting & stacking the selected stuff for reuse in aradius of 50 m and lift upto 1.5 m including cost of labour, tools & otherappurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of work | Cum | 254.1 | 254.1 | 18.32 | False | None | None | False | None | False | 4655.112 | 0 | 3496679 | 124883 | None | code16 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately).Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of work | Cum | 5947.2 | 5947.2 | 3.76 | False | None | None | False | None | False | 22361.472 | 0 | 3496680 | 124883 | None | code17 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of work | Cum | 5891.55 | 5891.55 | 4.78 | False | None | None | False | None | False | 28161.609 | 0 | 3496681 | 124883 | None | code18 | Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of work | Cum | 6948.9 | 6948.9 | 2.26 | False | None | None | False | None | False | 15704.514 | 0 | 3496682 | 124883 | None | code19 | Providing and laying in position Reinforced cement concrete for all Foundation works.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of work | Cum | 12256.05 | 12256.05 | 8.1 | False | None | None | False | None | False | 99274.005 | 0 | 3496683 | 124883 | None | code20 | Providing Thermo-Mechanically Treated bars of grade Fe-500D ormore Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including costof material, labour, usage charges complete as per specifications.(Thelaps and wastages shall not be measured separately) etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of work | MT | 93929.85 | 93929.85 | 0.891 | False | None | None | False | None | False | 83691.49635 | 0 | 3496684 | 124883 | None | code21 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of work | Sqm | 1375.5 | 1375.5 | 54.17 | False | None | None | False | None | False | 74510.835 | 0 | 3496685 | 124883 | None | code22 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding.20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of work | Cum | 279.3 | 279.3 | 17.11 | False | None | None | False | None | False | 4778.823 | 0 | 3496686 | 124883 | None | code23 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of work | Sqm | 371.7 | 371.7 | 116.48 | False | None | None | False | None | False | 43295.616 | 0 | 3496687 | 124883 | None | code24 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of work | Sqm | 933.45 | 933.45 | 19.25 | False | None | None | False | None | False | 17968.9125 | 0 | 3496688 | 124883 | None | code25 | Finishing walls with water proofing cement paint of required shade :Old work (one coats applied @ 2.20 kg/10 m²) over priming coat of primer applied @ 0.80 litrs/10 m² complete including cost of Priming coat including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of work | Sqm | 91.35 | 91.35 | 116.48 | False | None | None | False | None | False | 10640.448 | 0 | 3496689 | 124883 | None | code26 | Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly.cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of work | cm | 4.2 | 4.2 | 5500.0 | False | None | None | False | None | False | 23100.0 | 0 | 3496690 | 124883 | None | code27 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of work | Sqm | 2764.65 | 2764.65 | 3.78 | False | None | None | False | None | False | 10450.377 | 0 | 3496691 | 124883 | None | code28 | Supplying Heavy Guage PVC Conduit pipe 19/20 Dia 2mm thick confirming to IS 2509 with suitable size bends metal /PVC junction boxes ,adhesive paste etc.., and running before concreting the slab.The conduite should be tied to the before reinforcement rods by using binding wires & unused ways of junction boxes and pipe ends should be covered using PVC end enclousees,run with 18SWG GI fishes wire wherever necessary etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of work | Mtr | 69.0 | 69.0 | 15.0 | False | None | None | False | None | False | 1035.0 | 0 | 3496692 | 124883 | None | code29 | Wiring for lighting/Power circute using one of FRLS PVC insulated 1100V Grade Multi Starded copper with low conducter Resistence single core wire is open or concealed system of wiring with Specified IS -694:1990 and Confirming to GTP of Group A 4 sqmm etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of work | Mtr | 63.0 | 63.0 | 15.0 | False | None | None | False | None | False | 945.0 | 0 | 3496693 | 124883 | None | code30 | Supplying & adopting Loop System of in Existing PVC Conductor/Casing ,Caping Using 1100 V Grade copper conductor Flexible multi strand FRLS PVC insulated 2x1 Sqmm able with low conducter Resistence single core wire is open or concealed system of wiring Confirming to GTP without swich the ohter end of wire shall be terminted with sufficent Loose length in a wood /PVC Round Block complete for Each outlet Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of work | Point | 394.0 | 394.0 | 2.0 | False | None | None | False | None | False | 788.0 | 0 | 3496694 | 124883 | None | code31 | Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6Amps 3/5 Way etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of work | Point | 103.0 | 103.0 | 2.0 | False | None | None | False | None | False | 206.0 | 0 | 3496695 | 124883 | None | code32 | Supplying & Fixing Superior Quality modular switch mounting poly corbonate plate with Necessary supporying Backplate with Required Nos of Machine Screws Bolts ,Nuts Etc., Complete on the Existing Metal /PVC Box 4 module etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of work | Point | 175.0 | 175.0 | 4.0 | False | None | None | False | None | False | 700.0 | 0 | 3496696 | 124883 | None | code33 | Supplying & fixing of retrofit type LED bulb W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater 70 greater than efficacy greater than 80 lumen per W, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should lesser than 5 percentage of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20 percentage, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition | Each | 425.0 | 425.0 | 2.0 | False | None | None | False | None | False | 850.0 | 0 | 3496697 | 124883 | None | code34 | Supplying& Fixing miniture circute breaker Existing MCB distribution Board using necessary fixing Material & C Type curve Indictor ON/OFF Energy cross-3 with short circute breaking capacity of 10K & complete wiring as required confirming IEC 60898 40-63Amps TPN etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of work | Each | 3044.0 | 3044.0 | 1.0 | False | None | None | False | None | False | 3044.0 | 0 | 3496698 | 124883 | None | code35 | GESCOM Deposite Charges for RR NO. | No | 9460.0 | 9460.0 | 1.0 | False | None | None | False | None | False | 9460.0 | 0 | 3496699 | 124883 | None | code36 | Supplying & Fixing Ceiling Fan etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of work | No | 2677.0 | 2677.0 | 1.0 | False | None | None | False | None | False | 2677.0 | 0 | 3496700 | 124883 | None | code37 | 1000 LPH PURE DRINKING WATER PLANT (RO, UF+UV) SS SKID TYPE :Water purification plants: Supplying, Installation and Commissioning of automatic Water purification plant (RO+UF) with all accessories piping,product water tank on single phase power supply as per the encloseddetailed Technical Specifications including cost of material, loadingand unloading and as directed by the Engineer in charge. (Ref- detailed specification enclosed seperatly). Note:- 1.The above rates mentioned are only for the preparation of estimate purpose. 2. All items are to be of BSI /NFS standards,with BSI / NFS mark . 3. Tenders to beinvited for procurement. 4. No direct payment should be made under any situation or condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge. Note : Refer the ANNEXURE : F for Detailed Specification of Each components etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of work | No | 463050.0 | 463050.0 | 1.0 | False | None | None | False | None | False | 463050.0 | 0 | 3496701 | 124883 | None | code38 | PIPELINE : Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m | Cum | 508.2 | 508.2 | 166.68 | False | None | None | False | None | False | 84706.776 | 0 | 3496702 | 124883 | None | code39 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, layingtrue to line, level and perfect linking at joints leak proof includingjointing of approved type with all labour charges and all lift charges,handling charges including encasing the pipe around to a depth not lessthan 15 cms with gravel or selected earth available from the excavationetc. complete. PVC pipes 63mm dia., 6 kg/sqcm & class 3 etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of work | Mtr | 169.05 | 169.05 | 343.0 | False | None | None | False | None | False | 57984.15 | 0 | 3496703 | 124883 | None | code40 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, layingtrue to line, level and perfect linking at joints leak proof includingjointing of approved type with all labour charges and all lift charges,handling charges including encasing the pipe around to a depth not lessthan 15 cms with gravel or selected earth available from the excavationetc. complete. PVC pipes 25mm dia, 10 kg/sqcm & class 5 etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of work | Mtr | 70.35 | 70.35 | 120.0 | False | None | None | False | None | False | 8442.0 | 0 | 3496704 | 124883 | None | code41 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications etc., complete as per specification, design and drawings including cost of all material, labour charges and hirecharges of machineries with all lead and lift as directed by the Engineer-in-charge of work | Cum | 168.0 | 168.0 | 166.68 | False | None | None | False | None | False | 28002.24 | 0 |
|