createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1720003542696
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd470000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose18-07-2024 16:00:00
tenderQueryClose15-07-2024 16:00:00
technicalBidOpen20-07-2024 16:00:00
publishedDate09-07-2024 19:24:41
publishedByPostKHB_EE2_CO_BNG
publishedByUserKPE11678 - LOKESHBABU C G
bidValidityPeriod180
noOfCalls1
preBidMeetingDate16-07-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonLokesh Babu C G
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08022273511
mobileNumber8022273511
tenderSupplierListNone
tenderSchedule
createdTs1720003542717
version4
createdDateNone
modifiedDateNone
tenderNumberKHB/2024-25/BD/WORK_INDENT250
titleConstruction of Government First Grade College Building at Hoskote, Bengaluru Rural District under SCP/TSP 2023-24 Scheme
descriptionConstruction of Government First Grade College Building at Hoskote, Bengaluru Rural District under SCP/TSP 2023-24 Scheme
categoryWORKS
categoryTextWorks
ecv31214366.93
deptNameKarnataka Housing Board
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location5488
locationNameKHB Central Office Bengaluru
provisionalAmount31214367.0
groupOverheadTotalNone
fileNumber155/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17200035430000NoneNoneBuildingsConstruction of Government First Grade College Building at Hoskote, Bengaluru Rural District under SCP/TSP 2023-24 Scheme31214366.93
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3443382122276Nonecode01Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.Sqm404.79404.791.42FalseNoneNoneFalseNoneFalse574.80180
3443383122276Nonecode02Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m, as per drawing and technical specification, including setting out, shorting, barricading, caution lights, including dressing of excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including the cost of labour, tools, usage of machinery and other appurtenances required to complete the work in all kinds of soils Depth upto 3m. By II)Mechanical Means using Dozer A)In area of light junglePageCum105.06105.06216.94FalseNoneNoneFalseNoneFalse22791.71640
3443384122276Nonecode03Earthwork excavation for Foundation by mechanical means for all works & depths up to 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing of or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including the cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In ordinary/soft rock without blasting up to 1.5 m depth. sl.no-1.16 pg.no-6, volume-1.Cum373.89373.8924.1FalseNoneNoneFalseNoneFalse9010.7490
3443385122276Nonecode04Providing and Filling in foundation with granite/trap broken [metal100mm and down size with approved M-Sand including hand packing, ramming, watering including the cost of all materials and labour with all lead and lift complete as per specifications.Cum2762.462762.4620.57FalseNoneNoneFalseNoneFalse56823.80220
3443386122276Nonecode05Providing and laying in position plain cement concrete for leveling course for all works in the foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of [steel reinforcement & formwork shall be paid separately)-Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregatesCum6008.946008.9420.57FalseNoneNoneFalseNoneFalse123603.89580
3443387122276Nonecode06Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. Rate including cost of Formwork, Centering & Scaffolding. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for FootingsCum7048.177048.1744.62FalseNoneNoneFalseNoneFalse314489.34540
3443388122276Nonecode07Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. Rate including cost of Formwork, Centering & Scaffolding. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Plinth BeamCum11094.3411094.341.82FalseNoneNoneFalseNoneFalse20191.69880
3443389122276Nonecode08Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. Rate including cost of Formwork, Centering & Scaffolding. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates GROUND FLOOR PLINTH BEAMCum10572.4410572.4411.07FalseNoneNoneFalseNoneFalse117036.91080
3443390122276Nonecode09Filling available excavated earth (excluding rock) in trenches plinths, sides of foundations, and other similar works, etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum445.99445.99153.47FalseNoneNoneFalseNoneFalse68446.08530
3443391122276Nonecode10Providing Size Stone masonry with a hard stone in foundation & plinth with Cement mortar 1:6 (1 cement: 6 coarse sand)Cum6580.676580.679.36FalseNoneNoneFalseNoneFalse61595.07120
3443392122276Nonecode11Providing and laying in position plain cement concrete for leveling course for all works in the foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately, Rate including cost of Formwork, Centering & Scaffolding)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates.Cum6403.516403.515.21FalseNoneNoneFalseNoneFalse33362.28710
3443393122276Nonecode12Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For ColumnCum11982.0911982.093.59FalseNoneNoneFalseNoneFalse43015.70310
3443394122276Nonecode13Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For Column STAIRCASE COLUMN GROUND FLOOR TO FIRST FLOORCum12101.9112101.911.64FalseNoneNoneFalseNoneFalse19847.13240
3443395122276Nonecode14Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. FIRST FLOOR TO TERRACE FLOOR ( SUPER STR )Cum12101.9112101.919.93FalseNoneNoneFalseNoneFalse120171.96630
3443396122276Nonecode15Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. SECOND FLOOR TO TERRACE FLOORCum12221.7312221.7323.43FalseNoneNoneFalseNoneFalse286355.13390
3443397122276Nonecode16Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation [works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For BeamsCum11277.2611277.265.24FalseNoneNoneFalseNoneFalse59092.84240
3443398122276Nonecode17Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation [works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Beams For first floorCum11390.0411390.045.25FalseNoneNoneFalseNoneFalse59797.710
3443399122276Nonecode18Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation [works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Beams for BridgeCum11277.2611277.265.8FalseNoneNoneFalseNoneFalse65408.1080
3443400122276Nonecode19Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation [works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Beams For terrace floorCum11502.8111502.8121.27FalseNoneNoneFalseNoneFalse244664.76870
3443401122276Nonecode20Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation [works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Block - C For Beams For terrace floorCum11502.8111502.8161.7FalseNoneNoneFalseNoneFalse709723.3770
3443402122276Nonecode21Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, [Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For Lintle GROUND FLOOR - Staircase wall (BLOCK B)Cum11277.2611277.260.05FalseNoneNoneFalseNoneFalse563.8630
3443403122276Nonecode22Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, [Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For Lintle GROUND FLOOR - Staircase wall (BLOCK B)Cum11390.0411390.040.84FalseNoneNoneFalseNoneFalse9567.63360
3443404122276Nonecode23Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, [Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For Lintle GROUND FLOOR - Staircase wall (BLOCK B) TERRACE FLOOR (BLOCK B)Cum11502.8111502.810.1FalseNoneNoneFalseNoneFalse1150.2810
3443405122276Nonecode24Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, [Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For Lintle GROUND FLOOR - Toilet (BLOCK C)Cum11277.2611277.260.81FalseNoneNoneFalseNoneFalse9134.58060
3443406122276Nonecode25Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, [Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For Lintle FIRST FLOOR - Toilet (BLOCK C)Cum11390.0411390.040.81FalseNoneNoneFalseNoneFalse9225.93240
3443407122276Nonecode26Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, [Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For LintleCum11390.0411390.043.63FalseNoneNoneFalseNoneFalse41345.84520
3443408122276Nonecode27Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate Cill Concrete GROUND FLOOR - Staircase wall (BLOCK B)Cum11277.2611277.260.05FalseNoneNoneFalseNoneFalse563.8630
3443409122276Nonecode28Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate Cill Concrete FIRST FLOOR (BLOCK B)Cum11390.0411390.040.65FalseNoneNoneFalseNoneFalse7403.5260
3443410122276Nonecode29Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate Cill Concrete TERRACE FLOOR (BLOCK B)Cum11502.8111502.810.05FalseNoneNoneFalseNoneFalse575.14050
3443411122276Nonecode30Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate Cill Concrete GROUND FLOOR - Toilet (BLOCK C)Cum11277.2611277.260.41FalseNoneNoneFalseNoneFalse4623.67660
3443412122276Nonecode31Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate Cill Concrete FIRST FLOOR - Toilet (BLOCK C)Cum11390.0411390.040.41FalseNoneNoneFalseNoneFalse4669.91640
3443413122276Nonecode32Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate Cill Concrete SECOND FLOOR - Classrooms (BLOCK C)Cum11502.8111502.812.58FalseNoneNoneFalseNoneFalse29677.24980
3443414122276Nonecode33Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate GROUND FLOOR - Staircase wall (BLOCK B)Cum7048.297048.290.2FalseNoneNoneFalseNoneFalse1409.6580
3443415122276Nonecode34Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate FIRST FLOOR (BLOCK B)Cum7118.777118.771.82FalseNoneNoneFalseNoneFalse12956.16140
3443416122276Nonecode35Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate TERRACE FLOOR (BLOCK B)Cum7189.267189.260.2FalseNoneNoneFalseNoneFalse1437.8520
3443417122276Nonecode36Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate SECOND FLOOR - Classrooms (BLOCK C)Cum7189.267189.267.49FalseNoneNoneFalseNoneFalse53847.55740
3443418122276Nonecode37Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density of more than 1800kg/Cum and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - 1) 2005 and constructed with CM 1:4 as per IS 2572:2005 including the cost of all materials, labor, scaffolding, and curing, usage charges of machinery, etc complete as per specifications. Ground floorSqm1349.31349.348.14FalseNoneNoneFalseNoneFalse64955.3020
3443419122276Nonecode38Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density of more than 1800kg/Cum and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - 1) 2005 and constructed with CM 1:4 as per IS 2572:2005 including the cost of all materials, labor, scaffolding, and curing, usage charges of machinery, etc complete as per specifications. Total first floorSqm1362.791362.79393.21FalseNoneNoneFalseNoneFalse535862.65590
3443420122276Nonecode39Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density of more than 1800kg/Cum and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - 1) 2005 and constructed with CM 1:4 as per IS 2572:2005 including the cost of all materials, labor, scaffolding, and curing, usage charges of machinery, etc complete as per specifications. Total Terrace floorSqm1362.791362.79162.92FalseNoneNoneFalseNoneFalse222025.74680
3443421122276Nonecode40Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density of more than 1800kg/Cum and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - 1) 2005 and constructed with CM 1:4 as per IS 2572:2005 including the cost of all materials, labor, scaffolding, and curing, usage charges of machinery, etc complete as per specifications. Ground Floor Total QtySqm1349.31349.3199.5348FalseNoneNoneFalseNoneFalse269232.305640
3443422122276Nonecode41Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density of more than 1800kg/Cum and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - 1) 2005 and constructed with CM 1:4 as per IS 2572:2005 including the cost of all materials, labor, scaffolding, and curing, usage charges of machinery, etc complete as per specifications. First Floor Total QtySqm1362.791362.79200.59FalseNoneNoneFalseNoneFalse273362.04610
3443423122276Nonecode42Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density of more than 1800kg/Cum and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - 1) 2005 and constructed with CM 1:4 as per IS 2572:2005 including the cost of all materials, labor, scaffolding, and curing, usage charges of machinery, etc complete as per specifications. Second floor Total QtySqm1376.291376.291011.79FalseNoneNoneFalseNoneFalse1392516.45910
3443424122276Nonecode43Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density of more than 1800kg/Cum and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - 1) 2005 and constructed with CM 1:4 as per IS 2572:2005 including the cost of all materials, labor, scaffolding, and curing, usage charges of machinery, etc complete as per specifications. Parapet QtySqm1389.781389.78171.5FalseNoneNoneFalseNoneFalse238347.270
3443425122276Nonecode44Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. SlabCum10607.6810607.686.77FalseNoneNoneFalseNoneFalse71813.99360
3443426122276Nonecode45Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. First floor + mumty stair areaCum10607.6810607.689.04FalseNoneNoneFalseNoneFalse95893.42720
3443427122276Nonecode46Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Terrace slabCum10607.6810607.6846.72FalseNoneNoneFalseNoneFalse495590.80960
3443428122276Nonecode47Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Connecting CorridorCum10607.6810607.684.31FalseNoneNoneFalseNoneFalse45719.10080
3443429122276Nonecode48Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Bath RoofCum10607.6810607.6816.05FalseNoneNoneFalseNoneFalse170253.2640
3443430122276Nonecode49Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Terrace slabCum10607.6810607.68109.8FalseNoneNoneFalseNoneFalse1164723.2640
3443431122276Nonecode50Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates StaircaseCum10220.0210220.026.27FalseNoneNoneFalseNoneFalse64079.52540
3443432122276Nonecode51Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates StaircaseCum10322.2210322.226.27FalseNoneNoneFalseNoneFalse64720.31940
3443433122276Nonecode52Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates StaircaseCum10424.4210424.426.27FalseNoneNoneFalseNoneFalse65361.11340
3443434122276Nonecode53Providing Thermo-Mechanically Treated bars of gradeFe-550Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding, and anchoring to adjacent members wherever necessary complete as per Design including the cost of material, labor, and usage charges complete as per specifications. (The laps and wastages shall not be measured separately)Tonne92140.7192140.719.15FalseNoneNoneFalseNoneFalse843087.49650
3443435122276Nonecode54Providing Thermo-Mechanically Treated bars of gradeFe-550Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding, and anchoring to adjacent members wherever necessary complete as per Design including the cost of material, labor, and usage charges complete as per specifications. (The laps and wastages shall not be measured separately) First FloorTonne93062.1293062.1213.13FalseNoneNoneFalseNoneFalse1221905.63560
3443436122276Nonecode55Providing Thermo-Mechanically Treated bars of gradeFe-550Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding, and anchoring to adjacent members wherever necessary complete as per Design including the cost of material, labor, and usage charges complete as per specifications. (The laps and wastages shall not be measured separately) Second FloorTonne93062.1293062.1231.95FalseNoneNoneFalseNoneFalse2973334.7340
3443437122276Nonecode56Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications FIRST FLOOR (BLOCK B)Cum102797.24102797.240.47FalseNoneNoneFalseNoneFalse48314.70280
3443438122276Nonecode57Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications TERRACE FLOOR (BLOCK B)Cum103815.04103815.040.12FalseNoneNoneFalseNoneFalse12457.80480
3443439122276Nonecode58Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications GROUND FLOOR - Toilet (BLOCK C)Cum101779.45101779.451.23FalseNoneNoneFalseNoneFalse125188.72350
3443440122276Nonecode59Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications FIRST FLOOR - Toilet (BLOCK C)Cum102797.24102797.241.23FalseNoneNoneFalseNoneFalse126440.60520
3443441122276Nonecode60Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications SECOND FLOOR - Toilet (BLOCK C)Cum103815.04103815.041.23FalseNoneNoneFalseNoneFalse127692.49920
3443442122276Nonecode61Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications SECOND FLOOR - Classrooms (BLOCK C)Cum103815.04103815.041.62FalseNoneNoneFalseNoneFalse168180.36480
3443443122276Nonecode62Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TO2(Titanium Dioxide) at 6PHR with TE(Thermo Plastic Elastomer) and lead free, gaskets - grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOOR Staircase wall (BLOCK B)Sqm6936.026936.022.7FalseNoneNoneFalseNoneFalse18727.2540
3443444122276Nonecode63Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TO2(Titanium Dioxide) at 6PHR with TE(Thermo Plastic Elastomer) and lead free, gaskets - grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) FIRST FLOOR (BLOCK B)Sqm7005.387005.3824.3FalseNoneNoneFalseNoneFalse170230.7340
3443445122276Nonecode64Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TO2(Titanium Dioxide) at 6PHR with TE(Thermo Plastic Elastomer) and lead free, gaskets - grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) TERRACE FLOOR (BLOCK B)Sqm7074.747074.742.7FalseNoneNoneFalseNoneFalse19101.7980
3443446122276Nonecode65Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TO2(Titanium Dioxide) at 6PHR with TE(Thermo Plastic Elastomer) and lead free, gaskets - grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) SECOND FLOOR - Classrooms (BLOCK C)Sqm7144.17144.199.9FalseNoneNoneFalseNoneFalse713695.590
3443447122276Nonecode66Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE ( Thermo Plastic Elastomer) and lead free with gaskets grey color having isolated drainage and reinforced with Galvanized Iron profile through out the ventilator frame. The frame has an overall size of 39mm x 39mm with a Gi reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pinhead glass. The wall thickness of the frame shall be 2mm. Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for [minor T&Ps shall not be made) FIRST FLOOR Corridor (BLOCK B)Sqm5949.485949.483.24FalseNoneNoneFalseNoneFalse19276.31520
3443448122276Nonecode67Providing & fixing of louvered ventilator made out of multi-chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead-free with gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame has an overall size of 39mm x 39mm with a Gl reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pinhead glass. The wall thickness of the frame shall be 2mm. Maximum possible size - 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for [minor T&Ps shall not be made) FIRST FLOOR - Corridor (BLOCK B)Sqm5890.575890.575.88FalseNoneNoneFalseNoneFalse34636.55160
3443449122276Nonecode68Providing & fixing of louvered ventilator made out of multi-chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead-free with gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame has an overall size of 39mm x 39mm with a Gl reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white)will be used on the frame along with plastic parts for fixing the 4 mm pinhead glass. The wall thickness of the frame shall be 2mm. Maximum possible size - 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for [minor T&Ps shall not be made) FIRST FLOOR - Toilet (BLOCK C)Sqm5949.485949.485.88FalseNoneNoneFalseNoneFalse34982.94240
3443450122276Nonecode69Providing & fixing of louvered ventilator made out of multi-chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead-free with gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame has an overall size of 39mm x 39mm with a Gl reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pinhead glass. The wall thickness of the frame shall be 2mm. Maximum possible size - 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for [minor T&Ps shall not be made) SECOND FLOOR - Toilet (BLOCK C)Sqm6008.386008.385.88FalseNoneNoneFalseNoneFalse35329.27440
3443451122276Nonecode70Providing & fixing of louvered ventilator made out of multi-chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead-free with gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame has an overall size of 39mm x 39mm with a Gl reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white)will be used on the frame along with plastic parts for fixing the 4 mm pinhead glass. The wall thickness of the frame shall be 2mm. Maximum possible size - 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for [minor T&Ps shall not be made) SECOND FLOOR - Classrooms (BLOCK C)Sqm6008.386008.382.52FalseNoneNoneFalseNoneFalse15141.11760
3443452122276Nonecode71Providing and fixing flush door shutters made out of solid core block board type, well seasoned, chemically treated hardwood battens and internal frame with minimum 45 mm wide wooden frame around door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I)1991. from manufacturer complete as per spcification.-35 mm thick on both sides commercial FIRST FLOOR (BLOCK B)Sqm3455.883455.8814.4FalseNoneNoneFalseNoneFalse49764.6720
3443453122276Nonecode72Providing and fixing flush door shutters made out of solid core block board type, well seasoned, chemically treated hardwood battens and internal frame with minimum 45 mm wide wooden frame around door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I)1991. from manufacturer complete as per spcification.-35 mm thick on both sides commercial TERRACE FLOOR (BLOCK B)Sqm3490.093490.093.6FalseNoneNoneFalseNoneFalse12564.3240
3443454122276Nonecode73Providing and fixing flush door shutters made out of solid core block board type, well seasoned, chemically treated hardwood battens and internal frame with minimum 45 mm wide wooden frame around door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I)1991. from manufacturer complete as per spcification.-35 mm thick on both sides commercia GROUND FLOOR - Toilet (BLOCK C)Sqm3421.663421.6623.57FalseNoneNoneFalseNoneFalse80648.52620
3443455122276Nonecode74Providing and fixing flush door shutters made out of solid core block board type, well seasoned, chemically treated hardwood battens and internal frame with minimum 45 mm wide wooden frame around door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I)1991. from manufacturer complete as per spcification.-35 mm thick on both sides commercia FIRST FLOOR - Toilet (BLOCK C)Sqm3455.883455.8823.57FalseNoneNoneFalseNoneFalse81455.09160
3443456122276Nonecode75Providing and fixing flush door shutters made out of solid core block board type, well seasoned, chemically treated hardwood battens and internal frame with minimum 45 mm wide wooden frame around door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I)1991. from manufacturer complete as per spcification.-35 mm thick on both sides commercia SECOND FLOOR - Toilet (BLOCK C)Sqm3490.093490.0923.57FalseNoneNoneFalseNoneFalse82261.42130
3443457122276Nonecode76Providing and fixing flush door shutters made out of solid core block board type, well seasoned, chemically treated hardwood battens and internal frame with minimum 45 mm wide wooden frame around door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I)1991. from manufacturer complete as per spcification.-35 mm thick on both sides commercia SECOND FLOOR - Classrooms (BLOCK C)Sqm3490.093490.0943.01FalseNoneNoneFalseNoneFalse150108.77090
3443458122276Nonecode77Fixing of the door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of the frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including the cost of materials, and labour charges, complete as per specifications. sl.no-12.51, pg.no-104, volume-2.No1046.481046.4859.0FalseNoneNoneFalseNoneFalse61742.320
3443459122276Nonecode78Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. SL.NO-12.60, PG.NO-105, VOLUME-2.No1083.561083.5659.0FalseNoneNoneFalseNoneFalse63930.040
3443460122276Nonecode79Providing and fixing chromium-plated brass handles of 100/125 mm with necessary screws etc. complete. SL.NO-12.62, PG.NO 105, VOLUME-2.No244.11244.11144.0FalseNoneNoneFalseNoneFalse35151.840
3443461122276Nonecode80Providing and fixing bright finished brass butt hinges with necessary screws etc. complete :100x85x5.5mm. (heavy type)SI.no-12.75.3, pg.no-107,volume-2.No211.15211.15216.0FalseNoneNoneFalseNoneFalse45608.40
3443462122276Nonecode81Providing and fixing MS Hold fasts (SL. No 444, Page NoA-25, Basic Rate Rs. 50.00), volume-2.No51.551.5354.0FalseNoneNoneFalseNoneFalse18231.00
3443463122276Nonecode82Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingKg173.04173.0456.7FalseNoneNoneFalseNoneFalse9811.3680
3443464122276Nonecode83Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding FIRST FLOOR (BLOCK B)Kg174.77174.77510.3FalseNoneNoneFalseNoneFalse89185.1310
3443465122276Nonecode84Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding TERRACE FLOOR (BLOCK B)Kg176.5176.556.7FalseNoneNoneFalseNoneFalse10007.550
3443466122276Nonecode85Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding SECOND FLOOR - Classrooms (BLOCK C)Kg176.5176.52097.9FalseNoneNoneFalseNoneFalse370279.350
3443467122276Nonecode86Providing 12 mm cement plaster with Cement mortar 1:3 (1cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete. First floor + Mumty AreaSqm336.02336.0264.75FalseNoneNoneFalseNoneFalse21757.2950
3443468122276Nonecode87Providing 12 mm cement plaster with Cement mortar 1:3 (1cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete. First Floor RoofSqm336.02336.02358.19FalseNoneNoneFalseNoneFalse120359.00380
3443469122276Nonecode88Providing 12 mm cement plaster with Cement mortar 1:3 (1cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete. Back bath roofSqm339.34339.34115.03FalseNoneNoneFalseNoneFalse39034.28020
3443470122276Nonecode89Providing 12 mm cement plaster with Cement mortar 1:3 (1cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete. Second Floor RoofSqm339.34339.34841.8FalseNoneNoneFalseNoneFalse285656.4120
3443471122276Nonecode90Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. BLOCK BSqm376.98376.981268.95FalseNoneNoneFalseNoneFalse478368.7710
3443472122276Nonecode91Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. BLOCK CSqm376.98376.983327.39FalseNoneNoneFalseNoneFalse1254359.48220
3443473122276Nonecode92Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)- Mixn 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates.Cum6403.516403.5131.15FalseNoneNoneFalseNoneFalse199469.33650
3443474122276Nonecode93Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)- Mixn 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates.Cum6403.516403.5173.2FalseNoneNoneFalseNoneFalse468736.9320
3443475122276Nonecode94Providing and laying cinder concrete in cement 1:15 (1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. SI. No 7.18, Page No23, Volume-2.Cum2077.512077.5123.08FalseNoneNoneFalseNoneFalse47948.93080
3443476122276Nonecode95Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications.Sqm5487.845487.8429.73FalseNoneNoneFalseNoneFalse163153.48320
3443477122276Nonecode96Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications. First Floor to TERRACE FLOORSqm5542.725542.7229.73FalseNoneNoneFalseNoneFalse164785.06560
3443478122276Nonecode97Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications. Second to Terrace FloorSqm5597.65597.630.91FalseNoneNoneFalseNoneFalse173021.8160
3443479122276Nonecode98Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm. BLOCK BSqm1191.141191.14358.19FalseNoneNoneFalseNoneFalse426654.43660
3443480122276Nonecode99Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm. BLOCK CSqm1202.941202.94841.8FalseNoneNoneFalseNoneFalse1012634.8920
3443481122276Nonecode100Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. BLOCK CSqm1139.181139.18467.28FalseNoneNoneFalseNoneFalse532316.03040
3443482122276Nonecode101Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 It/10 m2 over and including one coat of Specialprimer applied @ 0.75 Itr /10 m with paint of approved quality to given even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR + MUMTY STAIR AREASqm164.37164.3764.75FalseNoneNoneFalseNoneFalse10642.95750
3443483122276Nonecode102Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 It/10 m2 over and including one coat of Specialprimer applied @ 0.75 Itr /10 m with paint of approved quality to given even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. First Floor Ceiling - Internal PaintSqm164.37164.37358.19FalseNoneNoneFalseNoneFalse58875.69030
3443484122276Nonecode103Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 It/10 m2 over and including one coat of Specialprimer applied @ 0.75 Itr /10 m with paint of approved quality to given even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Back bath roofSqm164.37164.37168.53FalseNoneNoneFalseNoneFalse27701.27610
3443485122276Nonecode104Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 It/10 m2 over and including one coat of Specialprimer applied @ 0.75 Itr /10 m with paint of approved quality to given even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. First Floor Ceiling - Internal PaintSqm164.37164.37841.8FalseNoneNoneFalseNoneFalse138366.6660
3443486122276Nonecode105Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications Two coats applied on walls @ 1.25 It/10 m over and including one coat of Specialprimer applied @ 0.75 Itr /10 m with paint of approved quality to given even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. BLOCK BSqm164.37164.371268.95FalseNoneNoneFalseNoneFalse208577.31150
3443487122276Nonecode106Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications Two coats applied on walls @ 1.25 It/10 m over and including one coat of Specialprimer applied @ 0.75 Itr /10 mwith paint of approved quality to given even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. BLOCK CSqm164.37164.373327.39FalseNoneNoneFalseNoneFalse546923.09430
3443488122276Nonecode107Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge. FIRST FLOOR (BLOCK B)Sqm58.2658.2614.4FalseNoneNoneFalseNoneFalse838.9440
3443489122276Nonecode108Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge.Sqm58.8358.833.6FalseNoneNoneFalseNoneFalse211.7880
3443490122276Nonecode109Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge GROUND FLOOR - Toilet (BLOCK C)Sqm57.6857.6823.57FalseNoneNoneFalseNoneFalse1359.51760
3443491122276Nonecode110Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge FIRST FLOOR - Toilet (BLOCK C)Sqm58.2658.2623.57FalseNoneNoneFalseNoneFalse1373.18820
3443492122276Nonecode111Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge SECOND FLOOR - Toilet (BLOCK C)Sqm58.8358.8323.57FalseNoneNoneFalseNoneFalse1386.62310
3443493122276Nonecode112Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge SECOND FLOOR - Classrooms (BLOCK C)Sqm58.8358.8343.01FalseNoneNoneFalseNoneFalse2530.27830
3443494122276Nonecode113Polishing on wood work with ready mixed wax polish of approved brand and manufacture: New work to give an even surface including preparing the surface after thorougly cleaning oil, grease dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. BLOCK BSqm140.44140.4486.4FalseNoneNoneFalseNoneFalse12134.0160
3443495122276Nonecode114Polishing on wood work with ready mixed wax polish of approved brand and manufacture: New work to give an even surface including preparing the surface after thorougly cleaning oil, grease dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. BLOCK CSqm140.44140.44545.81FalseNoneNoneFalseNoneFalse76653.55640
3443496122276Nonecode115Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge BLOCK BKg587.77587.7793.42FalseNoneNoneFalseNoneFalse54909.47340
3443497122276Nonecode116Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge BLOCK BKg593.59593.5993.42FalseNoneNoneFalseNoneFalse55453.17780
3443498122276Nonecode117Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge BLOCK CKg593.59593.5993.42FalseNoneNoneFalseNoneFalse55453.17780
3443499122276Nonecode118Providing and laying in position cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. BLOCK BCum9701.329701.3223.36FalseNoneNoneFalseNoneFalse226622.83520
3443500122276Nonecode119Providing and laying in position cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. BLOCK CCum9701.329701.3258.56FalseNoneNoneFalseNoneFalse568109.29920
3443501122276Nonecode120Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials labour, curing complete as per specifications and as per directions of Engineer-in-charge. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin-Charge. Terrace Floor (BLOCK BSqm380.75380.75311.47FalseNoneNoneFalseNoneFalse118592.20250
3443502122276Nonecode121Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials labour, curing complete as per specifications and as per directions of Engineer-in-charge. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin-Charge. Terrace Floor (BLOCK CSqm380.75380.75732.0FalseNoneNoneFalseNoneFalse278709.00
3443503122276Nonecode122Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. Terrace Floor (BLOCK B)Sqm849.93849.93311.47FalseNoneNoneFalseNoneFalse264727.69710
3443504122276Nonecode123Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. Terrace Floor (BLOCK C)Sqm849.93849.931098.0FalseNoneNoneFalseNoneFalse933223.140
3443505122276Nonecode124Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. Bath AreaSqm849.93849.9380.25FalseNoneNoneFalseNoneFalse68206.88250
3443506122276Nonecode125Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m, as per drawing and technical specification, including setting out, shorting, barricading, caution lights, including dressing of excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including the cost of labour, tools, usage of machinery and other appurtenances required to complete the work in all kinds of soils Depth upto 3m. Page No. 5, SI. No. 1.14,VOL-1Cum105.06105.06313.47FalseNoneNoneFalseNoneFalse32933.15820
3443507122276Nonecode126Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specificationsCum164.8164.8313.47FalseNoneNoneFalseNoneFalse51659.8560
3443508122276Nonecode127Providing and laying in position cement concrete of mix 1:3:6 with OPC cement @ 220kgs, with 20mm and down size graded granite metal coarse aggregates @0.84cum and fine aggregtes @ 0.56cum, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, plinth and cills, ncluding cost of all materials, labour, HOM of machinery, curing complete as per specifications. Specification No. I.No.2.1.3 vol-1Cum6168.676168.675.36FalseNoneNoneFalseNoneFalse33064.07120
3443509122276Nonecode128Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 100 mm nominal dia Pipes, VOL-II, I.NO.13.50.9m957.9957.9250.0FalseNoneNoneFalseNoneFalse239475.00
3443510122276Nonecode129Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm nominal dia Pipes External work VOL-II, I.NO.13.50.10m1640.791640.79528.0FalseNoneNoneFalseNoneFalse866337.120
3443511122276Nonecode130Providing and fixing white vitreous china water closet squatting pan (Indian type) : Orissa pattern W.C. pan of size 580x440 MM I.NO. 14.13.2 VOL.2Pan2400.932400.935.0FalseNoneNoneFalseNoneFalse12004.650
3443512122276Nonecode131Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid I.NO :14.3.1, VOL NO.IIEach6156.316156.3140.0FalseNoneNoneFalseNoneFalse246252.40
3443513122276Nonecode132Providing and fixing white vitreous china clay, flat back or half stall urinal basin of size 580x380x350mm with 5 litres P.V.C automatic flushing cistern, C.I / M.S brackets, standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps C.I dtrap with outlet grating and other couplings in C.P brass, painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete. Specification No. 11-9.1Each5124.255124.258.0FalseNoneNoneFalseNoneFalse40994.00
3443514122276Nonecode133Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. I.NO.14.23 VOL.1Each1188.621188.623.0FalseNoneNoneFalseNoneFalse3565.860
3443515122276Nonecode134Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps I.NO.14.7.1Each3174.463174.4630.0FalseNoneNoneFalseNoneFalse95233.80
3443516122276Nonecode135Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - 40 mm nominal dia Pipesm552.08552.0830.0FalseNoneNoneFalseNoneFalse16562.40
3443517122276Nonecode136Providing and fixing 100 mm sand cast Iron grating for gully trap. I.NO. 14.29 VOL-2Each48.4148.4135.0FalseNoneNoneFalseNoneFalse1694.350
3443518122276Nonecode137Providing and fixing brass bib cock of approved quality 15 mm nominal bore I.NO. 13.2.1 VOL-2Each195.7195.735.0FalseNoneNoneFalseNoneFalse6849.50
3443519122276Nonecode138Providing and fixing brass stop cock of approved quality 15 mm nominal boreNo307.97307.9735.0FalseNoneNoneFalseNoneFalse10778.950
3443520122276Nonecode139Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25 mm nominal boreNo565.47565.4735.0FalseNoneNoneFalseNoneFalse19791.450
3443521122276Nonecode140Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore I.NO.13.4.2Each615.94615.9435.0FalseNoneNoneFalseNoneFalse21557.90
3443522122276Nonecode141Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal dia Pipes I.NO.13.31.2 VOL-2m249.26249.261120.0FalseNoneNoneFalseNoneFalse279171.20
3443523122276Nonecode142Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes I.NO 13.31.3m327.54327.5476.0FalseNoneNoneFalseNoneFalse24893.040
3443524122276Nonecode143Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 32 mm nominal dia Pipes I.NO 13.31.4m412.0412.024.0FalseNoneNoneFalseNoneFalse9888.00
3443525122276Nonecode144Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 40 mm nominal dia Pipes I.NO 13.31.5m552.08552.08272.0FalseNoneNoneFalseNoneFalse150165.760
3443526122276Nonecode145Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 50 mm nominal dia Pipes I.NO 13.31.6m804.43804.4320.0FalseNoneNoneFalseNoneFalse16088.60
3443527122276Nonecode146Providing and constructing "WIRE CUT BRICK MACHINEHOLE CHAMBERS" using Portland/Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber. Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Providing and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Providing and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de-watering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm dia onstructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.0 M depth & SFRC cover & frameNo29918.4129918.414.0FalseNoneNoneFalseNoneFalse119673.640
3443528122276Nonecode147Constructing brick masonry circular type manhole 1.52 m internal dia at bottom 4.18m deep and 0.56m dia at top, with table moulded and non-modular bricks of class designation 50 in cement mortar 1:4, inside cement plaster 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 mixed using 40mm and down size granite metal and making necessary channel in cement concrete 1:2:4 mix with 20mm anddown size granite metal, finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diameter confirming to IS :12592, weight length of cover and frame to be not less than 182 kg, fixed in cement concrete M 15 20mm and down size broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. ( Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. 16.16.4No143549.04143549.042.0FalseNoneNoneFalseNoneFalse287098.080
3443529122276Nonecode148Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5No5811.265811.268.0FalseNoneNoneFalseNoneFalse46490.080
3443530122276Nonecode149constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 500X700 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets :With common burnt clay (non modular) bricks of class designation 3.5 13.54No6466.346466.344.0FalseNoneNoneFalseNoneFalse25865.360
3443531122276Nonecode150Extra for Item item no. KSRB 12-.8.1 depth beyound 450mm and brick masonry chamber with table moulded non modular bricks of class designation 50 in cement mortar 1:5 for every 150mm depth or part thereof including coat of materials, labour charges, curing complete as per specifications. Specification No. 0.45 to 0.6 & 0.6 to 0.75 the nos are 60 & 40No744.69744.698.0FalseNoneNoneFalseNoneFalse5957.520
3443532122276Nonecode151Providing and fixing in position 32mm nominal bore gun metal non-return valve horizontal type of approved make including cost of all materials, laboru and HOM of equipments with all leads complete as per specifications. Specification No. 13-6.2.1No833.27833.272.0FalseNoneNoneFalseNoneFalse1666.540
3443533122276Nonecode152Providing stoneware gully trap of approved quality and make fixing in M15 and plastering with CM 1:3 wherever necessary.( Rate includes cost of all materials, fixtures and lead). 15cms x 10cms. Specification No. 12.112.2No288.4288.48.0FalseNoneNoneFalseNoneFalse2307.20
3443534122276Nonecode153Making wall bore in stone masonry walls and Redoing upto 45cms thick. Specification No. 37.36.1No312.09312.0940.0FalseNoneNoneFalseNoneFalse12483.60
3443535122276Nonecode154Making wall bore in Brick masonry walls and Redoing 45cms thick. Specification No. 37.35No129.78129.7840.0FalseNoneNoneFalseNoneFalse5191.20
3443536122276Nonecode155Drilling holes of 2.50 cms dia (roof/chajja/stone). - - in slabs upto 10 cms thick. Specification No. 37.28.2No161.71161.714.0FalseNoneNoneFalseNoneFalse646.840
3443537122276Nonecode156Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.No9.279.274000.0FalseNoneNoneFalseNoneFalse37080.00
3443538122276Nonecode157Providing and fixing in position 50mm nominal bore gun metal non-return valve horizontal type of approved make including cost of all materials, Labour and HOM of equipments with all leads complete as per specifications.(Specifications No. KBS 13.2.10/13.13) Non return valves : Cimberio / RB / Itap. Specification No. 13.6.4.1No1401.831401.834.0FalseNoneNoneFalseNoneFalse5607.320
3443539122276Nonecode158Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. 2.2.1)Short point upto 3Mtr from tapping point to out let via switch boxNo277.07277.0735.0FalseNoneNoneFalseNoneFalse9697.450
3443540122276Nonecode159Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. 2.2.2)Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxNo390.37390.3750.0FalseNoneNoneFalseNoneFalse19518.50
3443541122276Nonecode160Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. 2.2.3)Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxNo571.65571.6515.0FalseNoneNoneFalseNoneFalse8574.750
3443542122276Nonecode161Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. 2.2.4)Two outlet in a row,above 3Mtr upto 6Mtr from tapping point to out let via switchesNo697.31697.3115.0FalseNoneNoneFalseNoneFalse10459.650
3443543122276Nonecode162Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. 2.2.5)Three outlet in a row, above 6Mts upto 10Mtr from tapping point to out let via switches boxNo1018.671018.6715.0FalseNoneNoneFalseNoneFalse15280.050
3443544122276Nonecode163Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.1) 1-2WayEach142.14142.1435.0FalseNoneNoneFalseNoneFalse4974.90
3443545122276Nonecode164Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.3)4-5WayEach182.31182.3116.0FalseNoneNoneFalseNoneFalse2916.960
3443546122276Nonecode165Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.4)6 WayEach226.6226.615.0FalseNoneNoneFalseNoneFalse3399.00
3443547122276Nonecode166Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.5)8WayEach268.83268.8316.0FalseNoneNoneFalseNoneFalse4301.280
3443548122276Nonecode167Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.6) 10-12WayEach328.57328.5712.0FalseNoneNoneFalseNoneFalse3942.840
3443549122276Nonecode168Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.7)16 WayEach373.89373.8920.0FalseNoneNoneFalseNoneFalse7477.80
3443550122276Nonecode169Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.8)18 WayEach417.15417.1525.0FalseNoneNoneFalseNoneFalse10428.750
3443551122276Nonecode170Suppling and fixing PVC/metal conduit deep juction boxes 1.5.1)19/20mm deep juction boxEach50.4750.4768.0FalseNoneNoneFalseNoneFalse3431.960
3443552122276Nonecode171Suppling and fixing PVC/metal conduit deep juction boxes 1.5.2) 25mm deep juction boxEach57.6857.6888.0FalseNoneNoneFalseNoneFalse5075.840
3443553122276Nonecode172Suppling and fixing PVC/metal conduit deep juction boxes 1.5.3) 32mm deep juction boxEach62.8362.8335.0FalseNoneNoneFalseNoneFalse2199.050
3443554122276Nonecode173Suppling and fixing PVC/metal conduit deep juction boxes 1.13)Suplay and fixing Metal Fan Box with Round HookEach120.51120.5165.0FalseNoneNoneFalseNoneFalse7833.150
3443555122276Nonecode174Supplying and mounting 2 nos of 2 way 6amps flush type switches either surface /flush mounted on exisinting gang box or in 4mm thick plastic sheet and mounted on a flush mounted wooden box and wiring as per IS 3854 . Page No. 5, Sl No 3.2Each175.1175.115.0FalseNoneNoneFalseNoneFalse2626.50
3443556122276Nonecode175Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.1)1 to 2 ModuleEach141.11141.1180.0FalseNoneNoneFalseNoneFalse11288.80
3443557122276Nonecode176Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.3) 4 ModuleEach180.25180.2555.0FalseNoneNoneFalseNoneFalse9913.750
3443558122276Nonecode177Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.4) 6 ModuleEach241.02241.0255.0FalseNoneNoneFalseNoneFalse13256.10
3443559122276Nonecode178Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.5)8 ModuleEach292.52292.5255.0FalseNoneNoneFalseNoneFalse16088.60
3443560122276Nonecode179Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.6)10-12 ModuleEach354.32354.3255.0FalseNoneNoneFalseNoneFalse19487.60
3443561122276Nonecode180Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.7)16 ModuleEach408.91408.9110.0FalseNoneNoneFalseNoneFalse4089.10
3443562122276Nonecode181Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.8)18 ModuleEach470.71470.7125.0FalseNoneNoneFalseNoneFalse11767.750
3443563122276Nonecode182Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.1) 6A one way switchEach105.06105.0675.0FalseNoneNoneFalseNoneFalse7879.50
3443564122276Nonecode183Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.3.6.2) 6A Two way switchEach170.98170.9825.0FalseNoneNoneFalseNoneFalse4274.50
3443565122276Nonecode184Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.3) 6A 3way socket.Each176.13176.1365.0FalseNoneNoneFalseNoneFalse11448.450
3443566122276Nonecode185Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.4) Stepped fan regulator two module.Each367.71367.7195.0FalseNoneNoneFalseNoneFalse34932.450
3443567122276Nonecode186Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.7) 16A one way switchEach185.4185.425.0FalseNoneNoneFalseNoneFalse4635.00
3443568122276Nonecode187Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.10) 6/16A universal socket.Each243.08243.0825.0FalseNoneNoneFalseNoneFalse6077.00
3443569122276Nonecode188Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.11) tv/telephone socketEach160.68160.6815.0FalseNoneNoneFalseNoneFalse2410.20
3443570122276Nonecode189Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.12) RJ 45/I.o outlet cat 6Each347.11347.1155.0FalseNoneNoneFalseNoneFalse19091.050
3443571122276Nonecode190Concealed Conduit System: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… and running before concreting th eslab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be convered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 1.2.1) 19/20mm dia 2mm thikm67.9867.982500.0FalseNoneNoneFalseNoneFalse169950.00
3443572122276Nonecode191Concealed Conduit System: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… and running before concreting th eslab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be convered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 1.2.2) 25mm dia 2mm thikm80.3480.341279.96FalseNoneNoneFalseNoneFalse102831.98640
3443573122276Nonecode192Concealed Conduit System: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… and running before concreting th eslab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be convered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 1.2.3) 32mm dia 2.5mm thikm106.09106.09550.0FalseNoneNoneFalseNoneFalse58349.50
3443574122276Nonecode193Groove cutting: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.1.3.1) 19/20mm dia 2mm thikm70.0470.04201.0FalseNoneNoneFalseNoneFalse14078.040
3443575122276Nonecode194Groove cutting: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 1.3.2) 25mm dia 2mm thikm81.3781.37650.0FalseNoneNoneFalseNoneFalse52890.50
3443576122276Nonecode195Groove cutting: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 1.3.3) 32mm dia 2.5mm thikm101.97101.97250.0FalseNoneNoneFalseNoneFalse25492.50
3443577122276Nonecode196Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010. 2.3.2) 1.5 sqmmm26.7826.78800.0FalseNoneNoneFalseNoneFalse21424.00
3443578122276Nonecode197Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010. 2.3.3) 2.5 sqmmm43.2643.26950.0FalseNoneNoneFalseNoneFalse41097.00
3443579122276Nonecode198Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010. 2.3.4) 4 sqmmm64.8964.89950.0FalseNoneNoneFalseNoneFalse61645.50
3443580122276Nonecode199Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010. 2.3.5) 6 sqmmm94.7694.76300.0FalseNoneNoneFalseNoneFalse28428.00
3443581122276Nonecode200Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 V as per IS-694:1990.e. 2.6.1)3C x 2.5 mm2m120.51120.5175.0FalseNoneNoneFalseNoneFalse9038.250
3443582122276Nonecode201Supplying and fixing regular MCB distribution boards on wall/ woodboard /flush mounting required clamps,bolts,nuts etc.. with provision for fixing suitable type capacity MCB's single phase /3 phase /single door with powder coated painting Madeoutof14SWGMS enclosure., complete. 6 Way TP & N double door ( SL No -5.19.12)Each5088.25088.29.0FalseNoneNoneFalseNoneFalse45793.80
3443583122276Nonecode202Supplying and fixing and wiring Residualcurrentcircuitbreaker(RCCB) 240/450V up 300mA sensitivity on exsiting wood/panel board 5.20.4)32-40 Amps 2 PoleEach4695.774695.778.0FalseNoneNoneFalseNoneFalse37566.160
3443584122276Nonecode203Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230/440 V 1/3 phase motor upto 5 HP. Sl No 5.1Each1984.811984.818.0FalseNoneNoneFalseNoneFalse15878.480
3443585122276Nonecode204Supplying&fixingminiaturecircuitbreakersonexistingMCBdistributionboardsusingnecessaryfixingmaterialsand'C'Typecurve,indicatorON/OFF,energycross- with Short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC60898 5.18.1)6-32Amps SPEach427.45427.4575.0FalseNoneNoneFalseNoneFalse32058.750
3443586122276Nonecode205Supplying&fixingminiaturecircuitbreakersonexistingMCBdistributionboardsusingnecessaryfixingmaterialsand'C'Typecurve,indicatorON/OFF,energycross- with Short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC60898 5.18.4)6-32Amps DPEach761.17761.178.0FalseNoneNoneFalseNoneFalse6089.360
3443587122276Nonecode206GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg. Page No. 22, Sl No. 51.01No683.29683.298.0FalseNoneNoneFalseNoneFalse5466.320
3443588122276Nonecode207Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each. Page No. 22, Sl No. 51.02No621.68621.688.0FalseNoneNoneFalseNoneFalse4973.440
3443589122276Nonecode208Good Quality Salt for grounding purposes packed in 50 Kg gunny bag. Page No. 22, Sl No. 51.03Each285.09285.098.0FalseNoneNoneFalseNoneFalse2280.720
3443590122276Nonecode209Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified. Page No. 23, Sl No. 51.04No1997.461997.468.0FalseNoneNoneFalseNoneFalse15979.680
3443591122276Nonecode210Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified. Page No. 23, Sl No. 51.05Each338.43338.438.0FalseNoneNoneFalseNoneFalse2707.440
3443592122276Nonecode211Digging of Pit for providing GI Pipe type Earthing. In Ordinary Soil. Page No. 43, Sl No. 1.6.1Each781.77781.776.0FalseNoneNoneFalseNoneFalse4690.620
3443593122276Nonecode212Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.. Guy Wire & GI Wire as per IS-2141. 8 SWG GI Wire (4.064 mm Dia), Std Wt: 125 Kg/KMTonne69010.069010.01.0FalseNoneNoneFalseNoneFalse69010.00
3443594122276Nonecode213Supply an fixing of …feet pvc batten with integrated led tube quality diffuser with life of 25000 burninng hours & 70% lumen maintance with CRI 80. power input :220-240V @ 50 hz & power factor .9 along with CE approved drivers. 2 years warranty. 11.3.1)LED light fitting 1x2' -9/10wEach567.53567.5355.0FalseNoneNoneFalseNoneFalse31214.150
3443595122276Nonecode214Supply an fixing of …feet pvc batten with integrated led tube quality diffuser with life of 25000 burninng hours & 70% lumen maintance with CRI 80. power input :220-240V @ 50 hz & power factor .9 along with CE approved drivers. 2 years warranty. 11.3.2)LED light fitting 1x4' -20/22wEach711.73711.73100.0FalseNoneNoneFalseNoneFalse71173.00
3443596122276Nonecode215Supplyofround /squarerecess/ surface mounted rolling type LED Downlight with......WGU10LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to main sconnector & hasswivelling unit of aluminium diecasteyeball & LED Lamp position retained by circular wirespring, with Life of 25000 burning hours & 70% lumenmaintenancewithCRI 80.PowerInput:220- 40V @50/60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition. 11.5.1)LED square or round down light 5-6WEach588.13588.1310.0FalseNoneNoneFalseNoneFalse5881.30
3443597122276Nonecode216Supplyofround /squarerecess/ surface mounted rolling type LED Downlight with......WGU10LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to main sconnector & hasswivelling unit of aluminium diecasteyeball & LED Lamp position retained by circular wirespring, with Life of 25000 burning hours & 70% lumenmaintenancewithCRI 80.PowerInput:220- 40V @50/60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition. 11.5.3)LED square or round down light 15-18WEach1363.721363.7225.0FalseNoneNoneFalseNoneFalse34093.00
3443598122276Nonecode217Supplying exhaust fan of 1440 RPM of 300 mm (12'') size with bracket blades complete for light duty suitable for operate of 230V 50Hz, AC Supply 12" Sweep (300 mm) sl no 6.2.1Each3058.073058.0730.0FalseNoneNoneFalseNoneFalse91742.10
3443599122276Nonecode218SupplyingofCeilingFanwithCapacitorratingAsperguidelineofBEE5starratingandIS:374/19andalsocomplywithIS:1709/1984withlatestamendment,Ratedvoltage220V/50Hz,Ratedpowerupto35W+/-10%,RatedcurrentAsperIS:374/19,Ratedpowerfactor0.9lagging(min),Ratedspeed350+/-10%RPM,Ratedairdelivery210+/-10%CubicMeterMinimum,Ratedservicevalue6.2CMM/W,ThreeBladesofbladeleaf1.05mmthickAluminiumAlloysheet,ClassBmotorinsulation,BearingTwoballbearings,Top6202,Bottom6201,asperISspecification,Motorwinding.TempriseShallnotexceed75degCoverandambientof400Cbyresistancemethodat245V,InsulationresistanceShallnotbelessthanTwoMegaOhms(2MOhms),LeakagecurrentShouldnotexceed210MicroAmp,Powerinput,W&current,AirDelivery&FanSpeedasperIS:374/2019withlatestamendment,2yearmanufacturerWarranty.(BLDC fans Regular model (Khaitan, Crompton Greaves, Orient, Polar, Bajaj, Usha, Havells, Almonard)Each2757.312757.3175.0FalseNoneNoneFalseNoneFalse206798.250
3443600122276Nonecode219Supplying of LT UG cable having aluminium conductor PVC insulated, sheathed, galvanised, steel wire/steel tap armoured cable with PVC outer sheathing 1.1 KV class .1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 I.Class 'A' PVC Cable 35 Sqmm, 3.5 Core, (14 GI Strips - 4 x 0.8 mm)Km141682.02141682.020.75FalseNoneNoneFalseNoneFalse106261.5150
3443601122276Nonecode220Supplying tinnd copper lugs and crimping and wiring to terminal point for wire of the following sizes. Heavy Duty Copper Terminal Long Barrel. 35 Sqmm Copper Terminal, Apprx Wt: 17 GmNo36.7936.798.0FalseNoneNoneFalseNoneFalse294.320
3443602122276Nonecode221Supplying and fixingof heavy duty cable glands suitable or UG cable o 1.1KV class (metal only). Page No. 28, Sl No. 63.02 32 mm diaNo87.3787.378.0FalseNoneNoneFalseNoneFalse698.960
3443603122276Nonecode222Supply & fixing of aution/Danger name board as per drawing( BESCOM SR . CDS-1) Page No. 32, Sl No. 68.17No137.95137.958.0FalseNoneNoneFalseNoneFalse1103.60
3443604122276Nonecode223Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. In ordinary. Page No. 8, Sl No. 29.02Cum267.8267.8787.5FalseNoneNoneFalseNoneFalse210892.50
3443605122276Nonecode224Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work In all kinds of soils. Depth upto 1.50m 1.6.1 vol-1Cum498.52498.52787.5FalseNoneNoneFalseNoneFalse392584.50
3443606122276Nonecode225PVC pipe-75mm dia (Page No 20of 40 Sl no:450). Page No. 15, Sl No. 48.07m147.14147.14100.0FalseNoneNoneFalseNoneFalse14714.00
3443607122276Nonecode226Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. Page No. 16, Sl No. 5.14Each10445.2310445.237.0FalseNoneNoneFalseNoneFalse73116.610
3443608122276Nonecode227Supplying of multi function digital meter with three line back light LCD type display for voltage,Current,frequency,Power,Powerfactor,KVA,KWH,KVARsuitable for 3 Phase,4 wire LT network with IP 54 degree of protection and completely wired as required wuth communication Port and Class 0.5s accuracy. a)Group AEach9594.459594.457.0FalseNoneNoneFalseNoneFalse67161.150
3443609122276Nonecode228Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.y FOUR Pole 5.14.7)100 A 25 kAEach8512.958512.957.0FalseNoneNoneFalseNoneFalse59590.650
3443610122276Nonecode229Supplying,fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based,digital readout of percentage leakage current,programable delay/auto/manual reset facility suitable to mount on DIN rail/flush munting on panel board. 5.17.9)50-63Amps TPNEach9532.659532.657.0FalseNoneNoneFalseNoneFalse66728.550
3443611122276Nonecode230Supplying, fixing and wiring 50/5A to 400/5A 5VA Burden class 1 Current Transformer. Page No. 19, Sl No. 5.34 a)Group AEach578.86578.867.0FalseNoneNoneFalseNoneFalse4052.020
3443612122276Nonecode231Supplying&fixingminiaturecircuitbreakersonexistingMCBdistributionboardsusingnecessaryfixingmaterialsand'C'Typecurve,indicatorON/OFF,energycross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirmingtoIEC60898.. 1 Group 'A' 5.18.8)40Amps TPNEach3135.323135.327.0FalseNoneNoneFalseNoneFalse21947.240
3443613122276Nonecode232Supplying&fixingminiaturecircuitbreakersonexistingMCBdistributionboardsusingnecessaryfixingmaterialsand'C'Typecurve,indicatorON/OFF,energycross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirmingtoIEC60898.. 1 Group 'A' 5.18.9)50-63Amps TPNEach3180.643180.645.0FalseNoneNoneFalseNoneFalse15903.20
3443614122276Nonecode233Supplying&fixingminiaturecircuitbreakersonexistingMCBdistributionboardsusingnecessaryfixingmaterialsand'C'Typecurve,indicatorON/OFF,energycross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirmingtoIEC60898.. 1 Group 'A' 5.18.5)40Amps DPEach1091.81091.85.0FalseNoneNoneFalseNoneFalse5459.00
3443615122276Nonecode234Supplying&fixingminiaturecircuitbreakersonexistingMCBdistributionboardsusingnecessaryfixingmaterialsand'C'Typecurve,indicatorON/OFF,energycross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirmingtoIEC60898.. 1 Group 'A' 5.18.4)6-32Amps DPEach761.17761.175.0FalseNoneNoneFalseNoneFalse3805.850
3443616122276Nonecode235Supplying …..amps rated 3phase with netural bus bar using required capacity electrolytic alluminium strips covered with heat shrinkable coloured PVC sleeve,mounted on phenolic/ERP/DMC insulator which are mounted on powder coated 40x6 mm M.S.flat frame work in existing panel board.The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts,nuts and washers etc.,complete. 5.40.1)100 A 4 x 30 x 6 mm Aluminium Stripsm2538.952538.958.0FalseNoneNoneFalseNoneFalse20311.60
3443617122276Nonecode236FabricatingsupplyingandmountingMSboxmadeout....SWGsuitableforfloor/wallmounting,fullyweatherproofwithprovisionforbetterheatdissipation,providedwithhingedfrontcover,equippedwithtamperprooflockingarrangements,withsuitablesizeclampswithnecessarycableentrypipewithglandandboxshouldbefinishedwith7tankstreatmentwithpowdercoatedpaintand finally finished with approved colour etc., complete. 5.42.1)14SWGSq CM0.520.5215000.0FalseNoneNoneFalseNoneFalse7800.00
3443618122276Nonecode237FabricatingsupplyingandmountingMSboxmadeout....SWGsuitableforfloor/wallmounting,fullyweatherproofwithprovisionforbetterheatdissipation,providedwithhingedfrontcover,equippedwithtamperprooflockingarrangements,withsuitablesizeclampswithnecessarycableentrypipewithglandandboxshouldbefinishedwith7tankstreatmentwithpowdercoatedpaintand finally finished with approved colour etc., complete. 5.42.2)16SWGSq CM0.440.4460000.0FalseNoneNoneFalseNoneFalse26400.00
3443619122276Nonecode238Supplying and fixing of LED type pannel board indicating lamp with reqired colour suitable for 230/440 V A.C.50 Hz 12/24v D.C. Page No. 19, Sl No. 5.38 a)Group AEach530.45530.4512.0FalseNoneNoneFalseNoneFalse6365.40
3443620122276Nonecode239Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.. Page No. 20, Sl No. 5.41 5.41.1)40 x 40 x 6 mmm314.15314.1510.0FalseNoneNoneFalseNoneFalse3141.50
3443621122276Nonecode240Supplying and drawing UTP-CAT 6E LAN cable. Page No. 36, Sl No. 8.1m39.1439.14950.0FalseNoneNoneFalseNoneFalse37183.00
3443622122276Nonecode241Supplying, erecting, testing & commissioning of OFF-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with all accessories complete and Excluding batteries and wiring complete...5KVA OFF LINE UPS Two Hour back up Excluding 6x 60Ah batteries. Page No. 38, Sl No. 9.2.5Each41094.9441094.945.0FalseNoneNoneFalseNoneFalse205474.70
3443623122276Nonecode24212 V 60 / 65 AH capacity CAPACTIY ACID BATTERY. Page No. 38, Sl No. 9.2.5Each41094.9441094.9415.0FalseNoneNoneFalseNoneFalse616424.10
3443624122276Nonecode243Arrange for the 1 energy metera, CHSCOM deposit, laisening work and including road cutting permission, etc. Page No. 28, ntLS20600.020600.06.0FalseNoneNoneFalseNoneFalse123600.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17200035440000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17200035440000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17200035440000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17200035440000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17200035440000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17200035490000NoneNoneELIGIBILITYThe tender document is part and parcel of the agreement.None
17200035650000NoneNoneELIGIBILITYThe contractor shall obtain insurance coverage for all the workers deployed for this work.None
17200035700000NoneNoneELIGIBILITYFurther details of the work or any clarifications can be obtained from the office of the Executive Engineer (Central office), KHB, Cauvery Bhavan, K.G. Road, Bangalore Ph: 080-22273511 ext-317,None
17200035740000NoneNoneELIGIBILITYThe intending bidders are requested to note that they should abide by the detailed instructions and conditions contained in the Tender documents and further modifications done if any.None
17200035780000NoneNoneELIGIBILITYCorrigendum/modification/corrections, if any, will be published in the e procurement Web sites only.None
17200035960000NoneNoneELIGIBILITYThe bidder shall study the Tender document Carefully and quote the ratesNone
17200036020000NoneNoneELIGIBILITYAll scanned documents to be uploaded shall be in original and are to be produced to the Executive Engineer to verify the documents within 3 days from the day of opening of Technical bid for verification, if required.None
17200036070000NoneNoneELIGIBILITYDrawings uploaded are only for Tender Purpose only.None
17200036100000NoneNoneELIGIBILITYGST shall be added separately in the estimate.None
17200036170000NoneNoneELIGIBILITYGST shall be paid to the tendered amount separately.None
17200036210000NoneNoneELIGIBILITYThe bidder should maintain register of laborers deployed and wages paid for the workers and shall produce the documents whenever called for by the competent authority. Remittance towards PF shall be commensurate with the labour component of the work involved.None
17200036240000NoneNoneELIGIBILITYThe bidder shall give an undertaking that they would abide by the provisions of employees provident fund and shall remit PF of labourers to the respective PF offices or else KHB have the right to deduct the PF amount from the work bills and remit the same to respective PF offices.None
17200036280000NoneNoneELIGIBILITYThe contractor shall quote his rates inclusive of PF as per the applicable rate as issued by the PF department from time to timeNone
17200036340000NoneNoneELIGIBILITYThe successful bidder shall give an under taking that they would abide by the provisions of the Employees Provident Fund Act.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneScanned Copy of documentary proof for having executed similar nature of work not less than 50% of tender amount as defined in Government order No.FD 480 EXP-12/2014,Bangalore dated:19.07.2014Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneScanned copy of Pre-qualification letter issued by Karnataka Housing Board.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned copy of Pre-qualification letter issued by Karnataka Housing Board.
NoneNoneNoneNoneAs per Tender Documents KW-4 clause 3.3 key & critical equipments available.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- As per Tender Documents KW-4 clause 3.3 key & critical equipments available.
NoneNoneNoneNoneExecuted in any one Financial year, the minimum quantities of work as mentioned in tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Executed in any one Financial year, the minimum quantities of work as mentioned in tender document
NoneNoneNoneNoneRequired valid electrical license for executing similar nature of work as per tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Required valid electrical license for executing similar nature of work as per tender document
NoneNoneNoneNoneThe Tenderer should have executed similar water supply/sanitary engineering works as per tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- The Tenderer should have executed similar water supply/sanitary engineering works as per tender document
NoneNoneNoneNoneIncome Tax returns & PANFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneITR Filed Copy (Mentioning PAN)
NoneNoneNoneNoneGST Registration CertificateFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneTo qualify for award of this contract , each tenderer in its name should have in the last five years achieved in at least two financial years a minimum financial turnover (In all classes of civil engineering construction works only)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneScanned copy of latest GST clearance certificate.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned copy of latest GST clearance certificate.
NoneNoneNoneNoneScanned copy of Credit lines/ letter of credit /Bankers certificate for at least 20% of amount put to tender in the current financial year on the name of work put to tender.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneAssessed Available Bid Capacity as per tender documentFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Assessed Available Bid Capacity as per tender document
NoneNoneNoneNoneCovering letter.OthersCovering letter.
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Covering letter.
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateFalseTechnical Bid
Reserved Category CertificateFalseTechnical Bid
Small Scale Industries CertificateFalseTechnical Bid
Work done certificateTrueTechnical Bid
key and critical equipment LISTTrueTechnical Bid
Income Tax returns & PAN no.TrueTechnical Bid
Pre-qualification certificate issued by KHBTrueTechnical Bid
GST clearance certificateTrueTechnical Bid
Credit lines/ letter of credit/Bankers certificateTrueTechnical Bid
Assessed available tender capacity calculationTrueTechnical Bid
Electrical licenseTrueTechnical Bid
Work done certificate with quantitiesTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1720532837000
version0
createdDateNone
modifiedDateNone
blockNumberCAUVERY BHAVAN 3RD FLOOR
streetNone
cityBengaluru
stateKarnataka
pin560009
tenderRecallDTONone