1720003543000 | 0 | None | None | Buildings | Construction of Government First Grade College Building at Hoskote, Bengaluru Rural District under SCP/TSP 2023-24 Scheme | 31214366.93 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3443382 | 122276 | None | code01 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. | Sqm | 404.79 | 404.79 | 1.42 | False | None | None | False | None | False | 574.8018 | 0 | 3443383 | 122276 | None | code02 | Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m, as per drawing and technical specification, including setting out, shorting, barricading, caution lights, including dressing of excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including the cost of labour, tools, usage of machinery and other appurtenances required to complete the work in all kinds of soils Depth upto 3m. By II)Mechanical Means using Dozer A)In area of light junglePage | Cum | 105.06 | 105.06 | 216.94 | False | None | None | False | None | False | 22791.7164 | 0 | 3443384 | 122276 | None | code03 | Earthwork excavation for Foundation by mechanical means for all works & depths up to 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing of or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including the cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In ordinary/soft rock without blasting up to 1.5 m depth. sl.no-1.16 pg.no-6, volume-1. | Cum | 373.89 | 373.89 | 24.1 | False | None | None | False | None | False | 9010.749 | 0 | 3443385 | 122276 | None | code04 | Providing and Filling in foundation with granite/trap broken [metal100mm and down size with approved M-Sand including hand packing, ramming, watering including the cost of all materials and labour with all lead and lift complete as per specifications. | Cum | 2762.46 | 2762.46 | 20.57 | False | None | None | False | None | False | 56823.8022 | 0 | 3443386 | 122276 | None | code05 | Providing and laying in position plain cement concrete for leveling course for all works in the foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of [steel reinforcement & formwork shall be paid separately)-Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6008.94 | 6008.94 | 20.57 | False | None | None | False | None | False | 123603.8958 | 0 | 3443387 | 122276 | None | code06 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. Rate including cost of Formwork,
Centering & Scaffolding. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Footings | Cum | 7048.17 | 7048.17 | 44.62 | False | None | None | False | None | False | 314489.3454 | 0 | 3443388 | 122276 | None | code07 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. Rate including cost of Formwork,
Centering & Scaffolding. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Plinth Beam | Cum | 11094.34 | 11094.34 | 1.82 | False | None | None | False | None | False | 20191.6988 | 0 | 3443389 | 122276 | None | code08 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. Rate including cost of Formwork,
Centering & Scaffolding. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
GROUND FLOOR PLINTH BEAM | Cum | 10572.44 | 10572.44 | 11.07 | False | None | None | False | None | False | 117036.9108 | 0 | 3443390 | 122276 | None | code09 | Filling available excavated earth (excluding rock) in trenches plinths, sides of foundations, and other similar works, etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 445.99 | 445.99 | 153.47 | False | None | None | False | None | False | 68446.0853 | 0 | 3443391 | 122276 | None | code10 | Providing Size Stone masonry with a hard stone in foundation & plinth with Cement mortar 1:6 (1 cement: 6 coarse sand) | Cum | 6580.67 | 6580.67 | 9.36 | False | None | None | False | None | False | 61595.0712 | 0 | 3443392 | 122276 | None | code11 | Providing and laying in position plain cement concrete for leveling course for all works in the foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately, Rate including cost of Formwork, Centering & Scaffolding)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 6403.51 | 6403.51 | 5.21 | False | None | None | False | None | False | 33362.2871 | 0 | 3443393 | 122276 | None | code12 | Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.
For Column | Cum | 11982.09 | 11982.09 | 3.59 | False | None | None | False | None | False | 43015.7031 | 0 | 3443394 | 122276 | None | code13 | Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.
For Column STAIRCASE COLUMN GROUND FLOOR TO FIRST FLOOR | Cum | 12101.91 | 12101.91 | 1.64 | False | None | None | False | None | False | 19847.1324 | 0 | 3443395 | 122276 | None | code14 | Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.
FIRST FLOOR TO TERRACE FLOOR ( SUPER STR ) | Cum | 12101.91 | 12101.91 | 9.93 | False | None | None | False | None | False | 120171.9663 | 0 | 3443396 | 122276 | None | code15 | Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. SECOND FLOOR TO TERRACE FLOOR | Cum | 12221.73 | 12221.73 | 23.43 | False | None | None | False | None | False | 286355.1339 | 0 | 3443397 | 122276 | None | code16 | Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation [works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
For Beams | Cum | 11277.26 | 11277.26 | 5.24 | False | None | None | False | None | False | 59092.8424 | 0 | 3443398 | 122276 | None | code17 | Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation [works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
For Beams For first floor | Cum | 11390.04 | 11390.04 | 5.25 | False | None | None | False | None | False | 59797.71 | 0 | 3443399 | 122276 | None | code18 | Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation [works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
For Beams for Bridge | Cum | 11277.26 | 11277.26 | 5.8 | False | None | None | False | None | False | 65408.108 | 0 | 3443400 | 122276 | None | code19 | Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation [works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
For Beams For terrace floor | Cum | 11502.81 | 11502.81 | 21.27 | False | None | None | False | None | False | 244664.7687 | 0 | 3443401 | 122276 | None | code20 | Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation [works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
Block - C For Beams For terrace floor | Cum | 11502.81 | 11502.81 | 61.7 | False | None | None | False | None | False | 709723.377 | 0 | 3443402 | 122276 | None | code21 | Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, [Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For Lintle GROUND FLOOR - Staircase wall (BLOCK B) | Cum | 11277.26 | 11277.26 | 0.05 | False | None | None | False | None | False | 563.863 | 0 | 3443403 | 122276 | None | code22 | Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, [Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For Lintle GROUND FLOOR - Staircase wall (BLOCK B) | Cum | 11390.04 | 11390.04 | 0.84 | False | None | None | False | None | False | 9567.6336 | 0 | 3443404 | 122276 | None | code23 | Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, [Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For Lintle GROUND FLOOR - Staircase wall (BLOCK B) TERRACE FLOOR (BLOCK B) | Cum | 11502.81 | 11502.81 | 0.1 | False | None | None | False | None | False | 1150.281 | 0 | 3443405 | 122276 | None | code24 | Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, [Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For Lintle GROUND FLOOR - Toilet (BLOCK C) | Cum | 11277.26 | 11277.26 | 0.81 | False | None | None | False | None | False | 9134.5806 | 0 | 3443406 | 122276 | None | code25 | Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, [Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For Lintle FIRST FLOOR - Toilet (BLOCK C) | Cum | 11390.04 | 11390.04 | 0.81 | False | None | None | False | None | False | 9225.9324 | 0 | 3443407 | 122276 | None | code26 | Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, [Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For Lintle | Cum | 11390.04 | 11390.04 | 3.63 | False | None | None | False | None | False | 41345.8452 | 0 | 3443408 | 122276 | None | code27 | Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate Cill Concrete GROUND FLOOR - Staircase wall (BLOCK B) | Cum | 11277.26 | 11277.26 | 0.05 | False | None | None | False | None | False | 563.863 | 0 | 3443409 | 122276 | None | code28 | Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate Cill Concrete FIRST FLOOR (BLOCK B) | Cum | 11390.04 | 11390.04 | 0.65 | False | None | None | False | None | False | 7403.526 | 0 | 3443410 | 122276 | None | code29 | Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate Cill Concrete TERRACE FLOOR (BLOCK B) | Cum | 11502.81 | 11502.81 | 0.05 | False | None | None | False | None | False | 575.1405 | 0 | 3443411 | 122276 | None | code30 | Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate Cill Concrete GROUND FLOOR - Toilet (BLOCK C) | Cum | 11277.26 | 11277.26 | 0.41 | False | None | None | False | None | False | 4623.6766 | 0 | 3443412 | 122276 | None | code31 | Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate Cill Concrete FIRST FLOOR - Toilet (BLOCK C) | Cum | 11390.04 | 11390.04 | 0.41 | False | None | None | False | None | False | 4669.9164 | 0 | 3443413 | 122276 | None | code32 | Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate Cill Concrete SECOND FLOOR - Classrooms (BLOCK C) | Cum | 11502.81 | 11502.81 | 2.58 | False | None | None | False | None | False | 29677.2498 | 0 | 3443414 | 122276 | None | code33 | Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate GROUND FLOOR - Staircase wall (BLOCK B) | Cum | 7048.29 | 7048.29 | 0.2 | False | None | None | False | None | False | 1409.658 | 0 | 3443415 | 122276 | None | code34 | Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate FIRST FLOOR (BLOCK B) | Cum | 7118.77 | 7118.77 | 1.82 | False | None | None | False | None | False | 12956.1614 | 0 | 3443416 | 122276 | None | code35 | Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate TERRACE FLOOR (BLOCK B) | Cum | 7189.26 | 7189.26 | 0.2 | False | None | None | False | None | False | 1437.852 | 0 | 3443417 | 122276 | None | code36 | Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate SECOND FLOOR - Classrooms (BLOCK C) | Cum | 7189.26 | 7189.26 | 7.49 | False | None | None | False | None | False | 53847.5574 | 0 | 3443418 | 122276 | None | code37 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density of more than 1800kg/Cum and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - 1) 2005 and constructed with CM 1:4 as per IS 2572:2005 including the cost of all materials, labor, scaffolding, and curing, usage charges of machinery, etc complete as per specifications. Ground floor | Sqm | 1349.3 | 1349.3 | 48.14 | False | None | None | False | None | False | 64955.302 | 0 | 3443419 | 122276 | None | code38 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density of more than 1800kg/Cum and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - 1) 2005 and constructed with CM 1:4 as per IS 2572:2005 including the cost of all materials, labor, scaffolding, and curing, usage charges of machinery, etc complete as per specifications. Total first floor | Sqm | 1362.79 | 1362.79 | 393.21 | False | None | None | False | None | False | 535862.6559 | 0 | 3443420 | 122276 | None | code39 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density of more than 1800kg/Cum and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - 1) 2005 and constructed with CM 1:4 as per IS 2572:2005 including the cost of all materials, labor, scaffolding, and curing, usage charges of machinery, etc complete as per specifications. Total Terrace floor | Sqm | 1362.79 | 1362.79 | 162.92 | False | None | None | False | None | False | 222025.7468 | 0 | 3443421 | 122276 | None | code40 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density of more than 1800kg/Cum and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - 1) 2005 and constructed with CM 1:4 as per IS 2572:2005 including the cost of all materials, labor, scaffolding, and curing, usage charges of machinery, etc complete as per specifications. Ground Floor Total Qty | Sqm | 1349.3 | 1349.3 | 199.5348 | False | None | None | False | None | False | 269232.30564 | 0 | 3443422 | 122276 | None | code41 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density of more than 1800kg/Cum and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - 1) 2005 and constructed with CM 1:4 as per IS 2572:2005 including the cost of all materials, labor, scaffolding, and curing, usage charges of machinery, etc complete as per specifications. First Floor Total Qty | Sqm | 1362.79 | 1362.79 | 200.59 | False | None | None | False | None | False | 273362.0461 | 0 | 3443423 | 122276 | None | code42 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density of more than 1800kg/Cum and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - 1) 2005 and constructed with CM 1:4 as per IS 2572:2005 including the cost of all materials, labor, scaffolding, and curing, usage charges of machinery, etc complete as per specifications. Second floor Total Qty | Sqm | 1376.29 | 1376.29 | 1011.79 | False | None | None | False | None | False | 1392516.4591 | 0 | 3443424 | 122276 | None | code43 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density of more than 1800kg/Cum and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - 1) 2005 and constructed with CM 1:4 as per IS 2572:2005 including the cost of all materials, labor, scaffolding, and curing, usage charges of machinery, etc complete as per specifications. Parapet Qty | Sqm | 1389.78 | 1389.78 | 171.5 | False | None | None | False | None | False | 238347.27 | 0 | 3443425 | 122276 | None | code44 | Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.
Slab | Cum | 10607.68 | 10607.68 | 6.77 | False | None | None | False | None | False | 71813.9936 | 0 | 3443426 | 122276 | None | code45 | Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. First floor + mumty stair area | Cum | 10607.68 | 10607.68 | 9.04 | False | None | None | False | None | False | 95893.4272 | 0 | 3443427 | 122276 | None | code46 | Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Terrace slab | Cum | 10607.68 | 10607.68 | 46.72 | False | None | None | False | None | False | 495590.8096 | 0 | 3443428 | 122276 | None | code47 | Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Connecting Corridor | Cum | 10607.68 | 10607.68 | 4.31 | False | None | None | False | None | False | 45719.1008 | 0 | 3443429 | 122276 | None | code48 | Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Bath Roof | Cum | 10607.68 | 10607.68 | 16.05 | False | None | None | False | None | False | 170253.264 | 0 | 3443430 | 122276 | None | code49 | Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Terrace slab | Cum | 10607.68 | 10607.68 | 109.8 | False | None | None | False | None | False | 1164723.264 | 0 | 3443431 | 122276 | None | code50 | Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
Staircase | Cum | 10220.02 | 10220.02 | 6.27 | False | None | None | False | None | False | 64079.5254 | 0 | 3443432 | 122276 | None | code51 | Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
Staircase | Cum | 10322.22 | 10322.22 | 6.27 | False | None | None | False | None | False | 64720.3194 | 0 | 3443433 | 122276 | None | code52 | Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
Staircase | Cum | 10424.42 | 10424.42 | 6.27 | False | None | None | False | None | False | 65361.1134 | 0 | 3443434 | 122276 | None | code53 | Providing Thermo-Mechanically Treated bars of gradeFe-550Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding, and anchoring to adjacent members wherever necessary complete as per Design including the cost of material, labor, and usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Tonne | 92140.71 | 92140.71 | 9.15 | False | None | None | False | None | False | 843087.4965 | 0 | 3443435 | 122276 | None | code54 | Providing Thermo-Mechanically Treated bars of gradeFe-550Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding, and anchoring to adjacent members wherever necessary complete as per Design including the cost of material, labor, and usage charges complete as per specifications. (The laps and wastages shall not be measured separately) First Floor | Tonne | 93062.12 | 93062.12 | 13.13 | False | None | None | False | None | False | 1221905.6356 | 0 | 3443436 | 122276 | None | code55 | Providing Thermo-Mechanically Treated bars of gradeFe-550Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding, and anchoring to adjacent members wherever necessary complete as per Design including the cost of material, labor, and usage charges complete as per specifications. (The laps and wastages shall not be measured separately) Second Floor | Tonne | 93062.12 | 93062.12 | 31.95 | False | None | None | False | None | False | 2973334.734 | 0 | 3443437 | 122276 | None | code56 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications FIRST FLOOR (BLOCK B) | Cum | 102797.24 | 102797.24 | 0.47 | False | None | None | False | None | False | 48314.7028 | 0 | 3443438 | 122276 | None | code57 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications TERRACE FLOOR (BLOCK B) | Cum | 103815.04 | 103815.04 | 0.12 | False | None | None | False | None | False | 12457.8048 | 0 | 3443439 | 122276 | None | code58 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications GROUND FLOOR - Toilet (BLOCK C) | Cum | 101779.45 | 101779.45 | 1.23 | False | None | None | False | None | False | 125188.7235 | 0 | 3443440 | 122276 | None | code59 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications FIRST FLOOR - Toilet (BLOCK C) | Cum | 102797.24 | 102797.24 | 1.23 | False | None | None | False | None | False | 126440.6052 | 0 | 3443441 | 122276 | None | code60 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications SECOND FLOOR - Toilet (BLOCK C) | Cum | 103815.04 | 103815.04 | 1.23 | False | None | None | False | None | False | 127692.4992 | 0 | 3443442 | 122276 | None | code61 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications SECOND FLOOR - Classrooms (BLOCK C) | Cum | 103815.04 | 103815.04 | 1.62 | False | None | None | False | None | False | 168180.3648 | 0 | 3443443 | 122276 | None | code62 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TO2(Titanium Dioxide) at 6PHR with TE(Thermo Plastic Elastomer) and lead free, gaskets - grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOOR Staircase wall (BLOCK B) | Sqm | 6936.02 | 6936.02 | 2.7 | False | None | None | False | None | False | 18727.254 | 0 | 3443444 | 122276 | None | code63 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TO2(Titanium Dioxide) at 6PHR with TE(Thermo Plastic Elastomer) and lead free, gaskets - grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) FIRST FLOOR (BLOCK B) | Sqm | 7005.38 | 7005.38 | 24.3 | False | None | None | False | None | False | 170230.734 | 0 | 3443445 | 122276 | None | code64 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TO2(Titanium Dioxide) at 6PHR with TE(Thermo Plastic Elastomer) and lead free, gaskets - grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) TERRACE FLOOR (BLOCK B) | Sqm | 7074.74 | 7074.74 | 2.7 | False | None | None | False | None | False | 19101.798 | 0 | 3443446 | 122276 | None | code65 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TO2(Titanium Dioxide) at 6PHR with TE(Thermo Plastic Elastomer) and lead free, gaskets - grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) SECOND FLOOR - Classrooms (BLOCK C) | Sqm | 7144.1 | 7144.1 | 99.9 | False | None | None | False | None | False | 713695.59 | 0 | 3443447 | 122276 | None | code66 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE ( Thermo Plastic Elastomer) and lead free with gaskets grey color having isolated drainage and reinforced with Galvanized Iron profile through out the ventilator frame. The frame has an overall size of 39mm x 39mm with a Gi reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pinhead glass. The wall thickness of the frame shall be 2mm. Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for [minor T&Ps shall not be made) FIRST FLOOR Corridor (BLOCK B) | Sqm | 5949.48 | 5949.48 | 3.24 | False | None | None | False | None | False | 19276.3152 | 0 | 3443448 | 122276 | None | code67 | Providing & fixing of louvered ventilator made out of multi-chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead-free with gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame has an overall size of 39mm x 39mm with a Gl reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pinhead glass. The wall thickness of the frame shall be 2mm. Maximum possible size - 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for [minor T&Ps shall not be made) FIRST FLOOR - Corridor (BLOCK B) | Sqm | 5890.57 | 5890.57 | 5.88 | False | None | None | False | None | False | 34636.5516 | 0 | 3443449 | 122276 | None | code68 | Providing & fixing of louvered ventilator made out of multi-chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead-free with gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame has an overall size of 39mm x 39mm with a Gl reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white)will be used on the frame along with plastic parts for fixing the 4 mm pinhead glass. The wall thickness of the frame shall be 2mm. Maximum possible size - 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for [minor T&Ps shall not be made) FIRST FLOOR - Toilet (BLOCK C) | Sqm | 5949.48 | 5949.48 | 5.88 | False | None | None | False | None | False | 34982.9424 | 0 | 3443450 | 122276 | None | code69 | Providing & fixing of louvered ventilator made out of multi-chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead-free with gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame has an overall size of 39mm x 39mm with a Gl reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pinhead glass. The wall thickness of the frame shall be 2mm. Maximum possible size - 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for [minor T&Ps shall not be made) SECOND FLOOR - Toilet (BLOCK C) | Sqm | 6008.38 | 6008.38 | 5.88 | False | None | None | False | None | False | 35329.2744 | 0 | 3443451 | 122276 | None | code70 | Providing & fixing of louvered ventilator made out of multi-chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead-free with gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame has an overall size of 39mm x 39mm with a Gl reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white)will be used on the frame along with plastic parts for fixing the 4 mm pinhead glass. The wall thickness of the frame shall be 2mm. Maximum possible size - 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for [minor T&Ps shall not be made) SECOND FLOOR - Classrooms (BLOCK C) | Sqm | 6008.38 | 6008.38 | 2.52 | False | None | None | False | None | False | 15141.1176 | 0 | 3443452 | 122276 | None | code71 | Providing and fixing flush door shutters made out of solid core block board type, well seasoned, chemically treated hardwood battens and internal frame with minimum 45 mm wide wooden frame around door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I)1991. from manufacturer complete as per spcification.-35 mm thick on both sides commercial FIRST FLOOR (BLOCK B) | Sqm | 3455.88 | 3455.88 | 14.4 | False | None | None | False | None | False | 49764.672 | 0 | 3443453 | 122276 | None | code72 | Providing and fixing flush door shutters made out of solid core block board type, well seasoned, chemically treated hardwood battens and internal frame with minimum 45 mm wide wooden frame around door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I)1991. from manufacturer complete as per spcification.-35 mm thick on both sides commercial TERRACE FLOOR (BLOCK B) | Sqm | 3490.09 | 3490.09 | 3.6 | False | None | None | False | None | False | 12564.324 | 0 | 3443454 | 122276 | None | code73 | Providing and fixing flush door shutters made out of solid core block board type, well seasoned, chemically treated hardwood battens and internal frame with minimum 45 mm wide wooden frame around door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I)1991. from manufacturer complete as per spcification.-35 mm thick on both sides commercia GROUND FLOOR - Toilet (BLOCK C) | Sqm | 3421.66 | 3421.66 | 23.57 | False | None | None | False | None | False | 80648.5262 | 0 | 3443455 | 122276 | None | code74 | Providing and fixing flush door shutters made out of solid core block board type, well seasoned, chemically treated hardwood battens and internal frame with minimum 45 mm wide wooden frame around door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I)1991. from manufacturer complete as per spcification.-35 mm thick on both sides commercia FIRST FLOOR - Toilet (BLOCK C) | Sqm | 3455.88 | 3455.88 | 23.57 | False | None | None | False | None | False | 81455.0916 | 0 | 3443456 | 122276 | None | code75 | Providing and fixing flush door shutters made out of solid core block board type, well seasoned, chemically treated hardwood battens and internal frame with minimum 45 mm wide wooden frame around door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I)1991. from manufacturer complete as per spcification.-35 mm thick on both sides commercia SECOND FLOOR - Toilet (BLOCK C) | Sqm | 3490.09 | 3490.09 | 23.57 | False | None | None | False | None | False | 82261.4213 | 0 | 3443457 | 122276 | None | code76 | Providing and fixing flush door shutters made out of solid core block board type, well seasoned, chemically treated hardwood battens and internal frame with minimum 45 mm wide wooden frame around door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I)1991. from manufacturer complete as per spcification.-35 mm thick on both sides commercia SECOND FLOOR - Classrooms (BLOCK C) | Sqm | 3490.09 | 3490.09 | 43.01 | False | None | None | False | None | False | 150108.7709 | 0 | 3443458 | 122276 | None | code77 | Fixing of the door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of the frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including the cost of materials, and labour charges, complete as per specifications. sl.no-12.51, pg.no-104, volume-2. | No | 1046.48 | 1046.48 | 59.0 | False | None | None | False | None | False | 61742.32 | 0 | 3443459 | 122276 | None | code78 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. SL.NO-12.60, PG.NO-105, VOLUME-2. | No | 1083.56 | 1083.56 | 59.0 | False | None | None | False | None | False | 63930.04 | 0 | 3443460 | 122276 | None | code79 | Providing and fixing chromium-plated brass handles of 100/125 mm with necessary screws etc. complete. SL.NO-12.62, PG.NO 105, VOLUME-2. | No | 244.11 | 244.11 | 144.0 | False | None | None | False | None | False | 35151.84 | 0 | 3443461 | 122276 | None | code80 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete :100x85x5.5mm. (heavy type)SI.no-12.75.3, pg.no-107,volume-2. | No | 211.15 | 211.15 | 216.0 | False | None | None | False | None | False | 45608.4 | 0 | 3443462 | 122276 | None | code81 | Providing and fixing MS Hold fasts (SL. No 444, Page NoA-25, Basic Rate Rs. 50.00), volume-2. | No | 51.5 | 51.5 | 354.0 | False | None | None | False | None | False | 18231.0 | 0 | 3443463 | 122276 | None | code82 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kg | 173.04 | 173.04 | 56.7 | False | None | None | False | None | False | 9811.368 | 0 | 3443464 | 122276 | None | code83 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding FIRST FLOOR (BLOCK B) | Kg | 174.77 | 174.77 | 510.3 | False | None | None | False | None | False | 89185.131 | 0 | 3443465 | 122276 | None | code84 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding TERRACE FLOOR (BLOCK B) | Kg | 176.5 | 176.5 | 56.7 | False | None | None | False | None | False | 10007.55 | 0 | 3443466 | 122276 | None | code85 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding SECOND FLOOR - Classrooms (BLOCK C) | Kg | 176.5 | 176.5 | 2097.9 | False | None | None | False | None | False | 370279.35 | 0 | 3443467 | 122276 | None | code86 | Providing 12 mm cement plaster with Cement mortar 1:3 (1cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete. First floor + Mumty Area | Sqm | 336.02 | 336.02 | 64.75 | False | None | None | False | None | False | 21757.295 | 0 | 3443468 | 122276 | None | code87 | Providing 12 mm cement plaster with Cement mortar 1:3 (1cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete. First Floor Roof | Sqm | 336.02 | 336.02 | 358.19 | False | None | None | False | None | False | 120359.0038 | 0 | 3443469 | 122276 | None | code88 | Providing 12 mm cement plaster with Cement mortar 1:3 (1cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete. Back bath roof | Sqm | 339.34 | 339.34 | 115.03 | False | None | None | False | None | False | 39034.2802 | 0 | 3443470 | 122276 | None | code89 | Providing 12 mm cement plaster with Cement mortar 1:3 (1cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete. Second Floor Roof | Sqm | 339.34 | 339.34 | 841.8 | False | None | None | False | None | False | 285656.412 | 0 | 3443471 | 122276 | None | code90 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. BLOCK B | Sqm | 376.98 | 376.98 | 1268.95 | False | None | None | False | None | False | 478368.771 | 0 | 3443472 | 122276 | None | code91 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. BLOCK C | Sqm | 376.98 | 376.98 | 3327.39 | False | None | None | False | None | False | 1254359.4822 | 0 | 3443473 | 122276 | None | code92 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)- Mixn 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 6403.51 | 6403.51 | 31.15 | False | None | None | False | None | False | 199469.3365 | 0 | 3443474 | 122276 | None | code93 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)- Mixn 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 6403.51 | 6403.51 | 73.2 | False | None | None | False | None | False | 468736.932 | 0 | 3443475 | 122276 | None | code94 | Providing and laying cinder concrete in cement 1:15 (1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. SI. No 7.18, Page No23, Volume-2. | Cum | 2077.51 | 2077.51 | 23.08 | False | None | None | False | None | False | 47948.9308 | 0 | 3443476 | 122276 | None | code95 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications. | Sqm | 5487.84 | 5487.84 | 29.73 | False | None | None | False | None | False | 163153.4832 | 0 | 3443477 | 122276 | None | code96 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications. First Floor to TERRACE FLOOR | Sqm | 5542.72 | 5542.72 | 29.73 | False | None | None | False | None | False | 164785.0656 | 0 | 3443478 | 122276 | None | code97 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications. Second to Terrace Floor | Sqm | 5597.6 | 5597.6 | 30.91 | False | None | None | False | None | False | 173021.816 | 0 | 3443479 | 122276 | None | code98 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm. BLOCK B | Sqm | 1191.14 | 1191.14 | 358.19 | False | None | None | False | None | False | 426654.4366 | 0 | 3443480 | 122276 | None | code99 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm. BLOCK C | Sqm | 1202.94 | 1202.94 | 841.8 | False | None | None | False | None | False | 1012634.892 | 0 | 3443481 | 122276 | None | code100 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. BLOCK C | Sqm | 1139.18 | 1139.18 | 467.28 | False | None | None | False | None | False | 532316.0304 | 0 | 3443482 | 122276 | None | code101 | Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 It/10 m2 over and including one coat of Specialprimer applied @ 0.75 Itr /10 m with paint of approved quality to given even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR + MUMTY STAIR AREA | Sqm | 164.37 | 164.37 | 64.75 | False | None | None | False | None | False | 10642.9575 | 0 | 3443483 | 122276 | None | code102 | Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 It/10 m2 over and including one coat of Specialprimer applied @ 0.75 Itr /10 m with paint of approved quality to given even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. First Floor Ceiling - Internal Paint | Sqm | 164.37 | 164.37 | 358.19 | False | None | None | False | None | False | 58875.6903 | 0 | 3443484 | 122276 | None | code103 | Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 It/10 m2 over and including one coat of Specialprimer applied @ 0.75 Itr /10 m with paint of approved quality to given even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Back bath roof | Sqm | 164.37 | 164.37 | 168.53 | False | None | None | False | None | False | 27701.2761 | 0 | 3443485 | 122276 | None | code104 | Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 It/10 m2 over and including one coat of Specialprimer applied @ 0.75 Itr /10 m with paint of approved quality to given even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. First Floor Ceiling - Internal Paint | Sqm | 164.37 | 164.37 | 841.8 | False | None | None | False | None | False | 138366.666 | 0 | 3443486 | 122276 | None | code105 | Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications Two coats applied on walls @ 1.25 It/10 m over and including one coat of Specialprimer applied @ 0.75 Itr /10 m with paint of approved quality to given even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. BLOCK B | Sqm | 164.37 | 164.37 | 1268.95 | False | None | None | False | None | False | 208577.3115 | 0 | 3443487 | 122276 | None | code106 | Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications Two coats applied on walls @ 1.25 It/10 m over and including one coat of Specialprimer applied @ 0.75 Itr /10 mwith paint of approved quality to given even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. BLOCK C | Sqm | 164.37 | 164.37 | 3327.39 | False | None | None | False | None | False | 546923.0943 | 0 | 3443488 | 122276 | None | code107 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge. FIRST FLOOR (BLOCK B) | Sqm | 58.26 | 58.26 | 14.4 | False | None | None | False | None | False | 838.944 | 0 | 3443489 | 122276 | None | code108 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge. | Sqm | 58.83 | 58.83 | 3.6 | False | None | None | False | None | False | 211.788 | 0 | 3443490 | 122276 | None | code109 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge GROUND FLOOR - Toilet (BLOCK C) | Sqm | 57.68 | 57.68 | 23.57 | False | None | None | False | None | False | 1359.5176 | 0 | 3443491 | 122276 | None | code110 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge FIRST FLOOR - Toilet (BLOCK C) | Sqm | 58.26 | 58.26 | 23.57 | False | None | None | False | None | False | 1373.1882 | 0 | 3443492 | 122276 | None | code111 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge SECOND FLOOR - Toilet (BLOCK C) | Sqm | 58.83 | 58.83 | 23.57 | False | None | None | False | None | False | 1386.6231 | 0 | 3443493 | 122276 | None | code112 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge SECOND FLOOR - Classrooms (BLOCK C) | Sqm | 58.83 | 58.83 | 43.01 | False | None | None | False | None | False | 2530.2783 | 0 | 3443494 | 122276 | None | code113 | Polishing on wood work with ready mixed wax polish of approved brand and manufacture: New work to give an even surface including preparing the surface after thorougly cleaning oil, grease dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. BLOCK B | Sqm | 140.44 | 140.44 | 86.4 | False | None | None | False | None | False | 12134.016 | 0 | 3443495 | 122276 | None | code114 | Polishing on wood work with ready mixed wax polish of approved brand and manufacture: New work to give an even surface including preparing the surface after thorougly cleaning oil, grease dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. BLOCK C | Sqm | 140.44 | 140.44 | 545.81 | False | None | None | False | None | False | 76653.5564 | 0 | 3443496 | 122276 | None | code115 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge BLOCK B | Kg | 587.77 | 587.77 | 93.42 | False | None | None | False | None | False | 54909.4734 | 0 | 3443497 | 122276 | None | code116 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge BLOCK B | Kg | 593.59 | 593.59 | 93.42 | False | None | None | False | None | False | 55453.1778 | 0 | 3443498 | 122276 | None | code117 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge BLOCK C | Kg | 593.59 | 593.59 | 93.42 | False | None | None | False | None | False | 55453.1778 | 0 | 3443499 | 122276 | None | code118 | Providing and laying in position cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. BLOCK B | Cum | 9701.32 | 9701.32 | 23.36 | False | None | None | False | None | False | 226622.8352 | 0 | 3443500 | 122276 | None | code119 | Providing and laying in position cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. BLOCK C | Cum | 9701.32 | 9701.32 | 58.56 | False | None | None | False | None | False | 568109.2992 | 0 | 3443501 | 122276 | None | code120 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials labour, curing complete as per specifications and as per directions of Engineer-in-charge. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin-Charge. Terrace Floor (BLOCK B | Sqm | 380.75 | 380.75 | 311.47 | False | None | None | False | None | False | 118592.2025 | 0 | 3443502 | 122276 | None | code121 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials labour, curing complete as per specifications and as per directions of Engineer-in-charge. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin-Charge. Terrace Floor (BLOCK C | Sqm | 380.75 | 380.75 | 732.0 | False | None | None | False | None | False | 278709.0 | 0 | 3443503 | 122276 | None | code122 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. Terrace Floor (BLOCK B) | Sqm | 849.93 | 849.93 | 311.47 | False | None | None | False | None | False | 264727.6971 | 0 | 3443504 | 122276 | None | code123 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. Terrace Floor (BLOCK C) | Sqm | 849.93 | 849.93 | 1098.0 | False | None | None | False | None | False | 933223.14 | 0 | 3443505 | 122276 | None | code124 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. Bath Area | Sqm | 849.93 | 849.93 | 80.25 | False | None | None | False | None | False | 68206.8825 | 0 | 3443506 | 122276 | None | code125 | Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m, as per drawing and technical specification, including setting out, shorting, barricading, caution lights, including dressing of excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including the cost of labour, tools, usage of machinery and other appurtenances required to complete the work in all kinds of soils Depth upto 3m. Page No. 5, SI. No. 1.14,VOL-1 | Cum | 105.06 | 105.06 | 313.47 | False | None | None | False | None | False | 32933.1582 | 0 | 3443507 | 122276 | None | code126 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications | Cum | 164.8 | 164.8 | 313.47 | False | None | None | False | None | False | 51659.856 | 0 | 3443508 | 122276 | None | code127 | Providing and laying in position cement concrete of mix 1:3:6 with OPC cement @ 220kgs, with 20mm and down size graded granite metal coarse aggregates @0.84cum and fine aggregtes @ 0.56cum, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, plinth and cills, ncluding cost of all materials, labour, HOM of machinery, curing complete as per specifications. Specification No. I.No.2.1.3 vol-1 | Cum | 6168.67 | 6168.67 | 5.36 | False | None | None | False | None | False | 33064.0712 | 0 | 3443509 | 122276 | None | code128 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 100 mm nominal dia Pipes, VOL-II, I.NO.13.50.9 | m | 957.9 | 957.9 | 250.0 | False | None | None | False | None | False | 239475.0 | 0 | 3443510 | 122276 | None | code129 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm nominal dia Pipes External work VOL-II, I.NO.13.50.10 | m | 1640.79 | 1640.79 | 528.0 | False | None | None | False | None | False | 866337.12 | 0 | 3443511 | 122276 | None | code130 | Providing and fixing white vitreous china water closet squatting pan (Indian type) : Orissa pattern W.C. pan of size 580x440 MM I.NO. 14.13.2 VOL.2 | Pan | 2400.93 | 2400.93 | 5.0 | False | None | None | False | None | False | 12004.65 | 0 | 3443512 | 122276 | None | code131 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid I.NO :14.3.1, VOL NO.II | Each | 6156.31 | 6156.31 | 40.0 | False | None | None | False | None | False | 246252.4 | 0 | 3443513 | 122276 | None | code132 | Providing and fixing white vitreous china clay, flat back or half stall urinal basin of size 580x380x350mm with 5 litres P.V.C automatic flushing cistern, C.I / M.S brackets, standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps C.I dtrap with outlet grating and other couplings in C.P brass, painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete. Specification No. 11-9.1 | Each | 5124.25 | 5124.25 | 8.0 | False | None | None | False | None | False | 40994.0 | 0 | 3443514 | 122276 | None | code133 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. I.NO.14.23 VOL.1 | Each | 1188.62 | 1188.62 | 3.0 | False | None | None | False | None | False | 3565.86 | 0 | 3443515 | 122276 | None | code134 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps I.NO.14.7.1 | Each | 3174.46 | 3174.46 | 30.0 | False | None | None | False | None | False | 95233.8 | 0 | 3443516 | 122276 | None | code135 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - 40 mm nominal dia Pipes | m | 552.08 | 552.08 | 30.0 | False | None | None | False | None | False | 16562.4 | 0 | 3443517 | 122276 | None | code136 | Providing and fixing 100 mm sand cast Iron grating for gully trap. I.NO. 14.29 VOL-2 | Each | 48.41 | 48.41 | 35.0 | False | None | None | False | None | False | 1694.35 | 0 | 3443518 | 122276 | None | code137 | Providing and fixing brass bib cock of approved quality 15 mm nominal bore I.NO. 13.2.1 VOL-2 | Each | 195.7 | 195.7 | 35.0 | False | None | None | False | None | False | 6849.5 | 0 | 3443519 | 122276 | None | code138 | Providing and fixing brass stop cock of approved quality 15 mm nominal bore | No | 307.97 | 307.97 | 35.0 | False | None | None | False | None | False | 10778.95 | 0 | 3443520 | 122276 | None | code139 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore | No | 565.47 | 565.47 | 35.0 | False | None | None | False | None | False | 19791.45 | 0 | 3443521 | 122276 | None | code140 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore I.NO.13.4.2 | Each | 615.94 | 615.94 | 35.0 | False | None | None | False | None | False | 21557.9 | 0 | 3443522 | 122276 | None | code141 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal dia Pipes I.NO.13.31.2 VOL-2 | m | 249.26 | 249.26 | 1120.0 | False | None | None | False | None | False | 279171.2 | 0 | 3443523 | 122276 | None | code142 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes I.NO 13.31.3 | m | 327.54 | 327.54 | 76.0 | False | None | None | False | None | False | 24893.04 | 0 | 3443524 | 122276 | None | code143 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 32 mm nominal dia Pipes I.NO 13.31.4 | m | 412.0 | 412.0 | 24.0 | False | None | None | False | None | False | 9888.0 | 0 | 3443525 | 122276 | None | code144 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 40 mm nominal dia Pipes I.NO 13.31.5 | m | 552.08 | 552.08 | 272.0 | False | None | None | False | None | False | 150165.76 | 0 | 3443526 | 122276 | None | code145 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 50 mm nominal dia Pipes I.NO 13.31.6 | m | 804.43 | 804.43 | 20.0 | False | None | None | False | None | False | 16088.6 | 0 | 3443527 | 122276 | None | code146 | Providing and constructing "WIRE CUT BRICK MACHINEHOLE CHAMBERS" using Portland/Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber. Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Providing and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Providing and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de-watering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm dia onstructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.0 M depth & SFRC cover & frame | No | 29918.41 | 29918.41 | 4.0 | False | None | None | False | None | False | 119673.64 | 0 | 3443528 | 122276 | None | code147 | Constructing brick masonry circular type manhole 1.52 m internal dia at bottom 4.18m deep and 0.56m dia at top, with table moulded and non-modular bricks of class designation 50 in cement mortar 1:4, inside cement plaster 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 mixed using 40mm and down size granite metal and making necessary channel in cement concrete 1:2:4 mix with 20mm anddown size granite metal, finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diameter confirming to IS :12592, weight length of cover and frame to be not less than 182 kg, fixed in cement concrete M 15 20mm and down size broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. ( Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. 16.16.4 | No | 143549.04 | 143549.04 | 2.0 | False | None | None | False | None | False | 287098.08 | 0 | 3443529 | 122276 | None | code148 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 | No | 5811.26 | 5811.26 | 8.0 | False | None | None | False | None | False | 46490.08 | 0 | 3443530 | 122276 | None | code149 | constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 500X700 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets :With common burnt clay (non modular) bricks of class designation 3.5 13.54 | No | 6466.34 | 6466.34 | 4.0 | False | None | None | False | None | False | 25865.36 | 0 | 3443531 | 122276 | None | code150 | Extra for Item item no. KSRB 12-.8.1 depth beyound 450mm and brick masonry chamber with table moulded non modular bricks of class designation 50 in cement mortar 1:5 for every 150mm depth or part thereof including coat of materials, labour charges, curing complete as per specifications. Specification No. 0.45 to 0.6 & 0.6 to 0.75 the nos are 60 & 40 | No | 744.69 | 744.69 | 8.0 | False | None | None | False | None | False | 5957.52 | 0 | 3443532 | 122276 | None | code151 | Providing and fixing in position 32mm nominal bore gun metal non-return valve horizontal type of approved make including cost of all materials, laboru and HOM of equipments with all leads complete as per specifications. Specification No. 13-6.2.1 | No | 833.27 | 833.27 | 2.0 | False | None | None | False | None | False | 1666.54 | 0 | 3443533 | 122276 | None | code152 | Providing stoneware gully trap of approved quality and make fixing in M15 and plastering with CM 1:3 wherever necessary.( Rate includes cost of all materials, fixtures and lead). 15cms x 10cms. Specification No. 12.112.2 | No | 288.4 | 288.4 | 8.0 | False | None | None | False | None | False | 2307.2 | 0 | 3443534 | 122276 | None | code153 | Making wall bore in stone masonry walls and Redoing upto 45cms thick. Specification No. 37.36.1 | No | 312.09 | 312.09 | 40.0 | False | None | None | False | None | False | 12483.6 | 0 | 3443535 | 122276 | None | code154 | Making wall bore in Brick masonry walls and Redoing 45cms thick. Specification No. 37.35 | No | 129.78 | 129.78 | 40.0 | False | None | None | False | None | False | 5191.2 | 0 | 3443536 | 122276 | None | code155 | Drilling holes of 2.50 cms dia (roof/chajja/stone). - - in slabs upto 10 cms thick. Specification No. 37.28.2 | No | 161.71 | 161.71 | 4.0 | False | None | None | False | None | False | 646.84 | 0 | 3443537 | 122276 | None | code156 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. | No | 9.27 | 9.27 | 4000.0 | False | None | None | False | None | False | 37080.0 | 0 | 3443538 | 122276 | None | code157 | Providing and fixing in position 50mm nominal bore gun metal non-return valve horizontal type of approved make including cost of all materials, Labour and HOM of equipments with all leads complete as per specifications.(Specifications No. KBS 13.2.10/13.13) Non return valves : Cimberio / RB / Itap. Specification No. 13.6.4.1 | No | 1401.83 | 1401.83 | 4.0 | False | None | None | False | None | False | 5607.32 | 0 | 3443539 | 122276 | None | code158 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. 2.2.1)Short point upto 3Mtr from tapping point to out let via switch box | No | 277.07 | 277.07 | 35.0 | False | None | None | False | None | False | 9697.45 | 0 | 3443540 | 122276 | None | code159 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. 2.2.2)Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box | No | 390.37 | 390.37 | 50.0 | False | None | None | False | None | False | 19518.5 | 0 | 3443541 | 122276 | None | code160 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. 2.2.3)Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box | No | 571.65 | 571.65 | 15.0 | False | None | None | False | None | False | 8574.75 | 0 | 3443542 | 122276 | None | code161 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. 2.2.4)Two outlet in a row,above 3Mtr upto 6Mtr from tapping point to out let via switches | No | 697.31 | 697.31 | 15.0 | False | None | None | False | None | False | 10459.65 | 0 | 3443543 | 122276 | None | code162 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. 2.2.5)Three outlet in a row, above 6Mts upto 10Mtr from tapping point to out let via switches box | No | 1018.67 | 1018.67 | 15.0 | False | None | None | False | None | False | 15280.05 | 0 | 3443544 | 122276 | None | code163 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.1) 1-2Way | Each | 142.14 | 142.14 | 35.0 | False | None | None | False | None | False | 4974.9 | 0 | 3443545 | 122276 | None | code164 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.3)4-5Way | Each | 182.31 | 182.31 | 16.0 | False | None | None | False | None | False | 2916.96 | 0 | 3443546 | 122276 | None | code165 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.4)6 Way | Each | 226.6 | 226.6 | 15.0 | False | None | None | False | None | False | 3399.0 | 0 | 3443547 | 122276 | None | code166 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.5)8Way | Each | 268.83 | 268.83 | 16.0 | False | None | None | False | None | False | 4301.28 | 0 | 3443548 | 122276 | None | code167 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.6) 10-12Way | Each | 328.57 | 328.57 | 12.0 | False | None | None | False | None | False | 3942.84 | 0 | 3443549 | 122276 | None | code168 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.7)16 Way | Each | 373.89 | 373.89 | 20.0 | False | None | None | False | None | False | 7477.8 | 0 | 3443550 | 122276 | None | code169 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.8)18 Way | Each | 417.15 | 417.15 | 25.0 | False | None | None | False | None | False | 10428.75 | 0 | 3443551 | 122276 | None | code170 | Suppling and fixing PVC/metal conduit deep juction boxes 1.5.1)19/20mm deep juction box | Each | 50.47 | 50.47 | 68.0 | False | None | None | False | None | False | 3431.96 | 0 | 3443552 | 122276 | None | code171 | Suppling and fixing PVC/metal conduit deep juction boxes 1.5.2) 25mm deep juction box | Each | 57.68 | 57.68 | 88.0 | False | None | None | False | None | False | 5075.84 | 0 | 3443553 | 122276 | None | code172 | Suppling and fixing PVC/metal conduit deep juction boxes 1.5.3) 32mm deep juction box | Each | 62.83 | 62.83 | 35.0 | False | None | None | False | None | False | 2199.05 | 0 | 3443554 | 122276 | None | code173 | Suppling and fixing PVC/metal conduit deep juction boxes 1.13)Suplay and fixing Metal Fan Box with Round Hook | Each | 120.51 | 120.51 | 65.0 | False | None | None | False | None | False | 7833.15 | 0 | 3443555 | 122276 | None | code174 | Supplying and mounting 2 nos of 2 way 6amps flush type switches either surface /flush mounted on exisinting gang box or in 4mm thick plastic sheet and mounted on a flush mounted wooden box and wiring as per IS 3854 . Page No. 5, Sl No 3.2 | Each | 175.1 | 175.1 | 15.0 | False | None | None | False | None | False | 2626.5 | 0 | 3443556 | 122276 | None | code175 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.1)1 to 2 Module | Each | 141.11 | 141.11 | 80.0 | False | None | None | False | None | False | 11288.8 | 0 | 3443557 | 122276 | None | code176 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.3) 4 Module | Each | 180.25 | 180.25 | 55.0 | False | None | None | False | None | False | 9913.75 | 0 | 3443558 | 122276 | None | code177 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.4) 6 Module | Each | 241.02 | 241.02 | 55.0 | False | None | None | False | None | False | 13256.1 | 0 | 3443559 | 122276 | None | code178 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.5)8 Module | Each | 292.52 | 292.52 | 55.0 | False | None | None | False | None | False | 16088.6 | 0 | 3443560 | 122276 | None | code179 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.6)10-12 Module | Each | 354.32 | 354.32 | 55.0 | False | None | None | False | None | False | 19487.6 | 0 | 3443561 | 122276 | None | code180 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.7)16 Module | Each | 408.91 | 408.91 | 10.0 | False | None | None | False | None | False | 4089.1 | 0 | 3443562 | 122276 | None | code181 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.8)18 Module | Each | 470.71 | 470.71 | 25.0 | False | None | None | False | None | False | 11767.75 | 0 | 3443563 | 122276 | None | code182 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.1) 6A one way switch | Each | 105.06 | 105.06 | 75.0 | False | None | None | False | None | False | 7879.5 | 0 | 3443564 | 122276 | None | code183 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.3.6.2) 6A Two way switch | Each | 170.98 | 170.98 | 25.0 | False | None | None | False | None | False | 4274.5 | 0 | 3443565 | 122276 | None | code184 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.3) 6A 3way socket. | Each | 176.13 | 176.13 | 65.0 | False | None | None | False | None | False | 11448.45 | 0 | 3443566 | 122276 | None | code185 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.4) Stepped fan regulator two module. | Each | 367.71 | 367.71 | 95.0 | False | None | None | False | None | False | 34932.45 | 0 | 3443567 | 122276 | None | code186 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.7) 16A one way switch | Each | 185.4 | 185.4 | 25.0 | False | None | None | False | None | False | 4635.0 | 0 | 3443568 | 122276 | None | code187 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.10) 6/16A universal socket. | Each | 243.08 | 243.08 | 25.0 | False | None | None | False | None | False | 6077.0 | 0 | 3443569 | 122276 | None | code188 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.11) tv/telephone socket | Each | 160.68 | 160.68 | 15.0 | False | None | None | False | None | False | 2410.2 | 0 | 3443570 | 122276 | None | code189 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.12) RJ 45/I.o outlet cat 6 | Each | 347.11 | 347.11 | 55.0 | False | None | None | False | None | False | 19091.05 | 0 | 3443571 | 122276 | None | code190 | Concealed Conduit System: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… and running before concreting th eslab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be convered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 1.2.1) 19/20mm dia 2mm thik | m | 67.98 | 67.98 | 2500.0 | False | None | None | False | None | False | 169950.0 | 0 | 3443572 | 122276 | None | code191 | Concealed Conduit System: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… and running before concreting th eslab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be convered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 1.2.2) 25mm dia 2mm thik | m | 80.34 | 80.34 | 1279.96 | False | None | None | False | None | False | 102831.9864 | 0 | 3443573 | 122276 | None | code192 | Concealed Conduit System: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… and running before concreting th eslab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be convered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 1.2.3) 32mm dia 2.5mm thik | m | 106.09 | 106.09 | 550.0 | False | None | None | False | None | False | 58349.5 | 0 | 3443574 | 122276 | None | code193 | Groove cutting: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.1.3.1) 19/20mm dia 2mm thik | m | 70.04 | 70.04 | 201.0 | False | None | None | False | None | False | 14078.04 | 0 | 3443575 | 122276 | None | code194 | Groove cutting: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 1.3.2) 25mm dia 2mm thik | m | 81.37 | 81.37 | 650.0 | False | None | None | False | None | False | 52890.5 | 0 | 3443576 | 122276 | None | code195 | Groove cutting: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 1.3.3) 32mm dia 2.5mm thik | m | 101.97 | 101.97 | 250.0 | False | None | None | False | None | False | 25492.5 | 0 | 3443577 | 122276 | None | code196 | Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010. 2.3.2) 1.5 sqmm | m | 26.78 | 26.78 | 800.0 | False | None | None | False | None | False | 21424.0 | 0 | 3443578 | 122276 | None | code197 | Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010. 2.3.3) 2.5 sqmm | m | 43.26 | 43.26 | 950.0 | False | None | None | False | None | False | 41097.0 | 0 | 3443579 | 122276 | None | code198 | Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010. 2.3.4) 4 sqmm | m | 64.89 | 64.89 | 950.0 | False | None | None | False | None | False | 61645.5 | 0 | 3443580 | 122276 | None | code199 | Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010. 2.3.5) 6 sqmm | m | 94.76 | 94.76 | 300.0 | False | None | None | False | None | False | 28428.0 | 0 | 3443581 | 122276 | None | code200 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 V as per IS-694:1990.e. 2.6.1)3C x 2.5 mm2 | m | 120.51 | 120.51 | 75.0 | False | None | None | False | None | False | 9038.25 | 0 | 3443582 | 122276 | None | code201 | Supplying and fixing regular MCB distribution boards on wall/ woodboard /flush mounting required clamps,bolts,nuts etc.. with provision for fixing suitable type capacity MCB's single phase /3 phase /single door with powder coated painting Madeoutof14SWGMS enclosure., complete. 6 Way TP & N double door ( SL No -5.19.12) | Each | 5088.2 | 5088.2 | 9.0 | False | None | None | False | None | False | 45793.8 | 0 | 3443583 | 122276 | None | code202 | Supplying and fixing and wiring Residualcurrentcircuitbreaker(RCCB) 240/450V up 300mA sensitivity on exsiting wood/panel board 5.20.4)32-40 Amps 2 Pole | Each | 4695.77 | 4695.77 | 8.0 | False | None | None | False | None | False | 37566.16 | 0 | 3443584 | 122276 | None | code203 | Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230/440 V 1/3 phase motor upto 5 HP. Sl No 5.1 | Each | 1984.81 | 1984.81 | 8.0 | False | None | None | False | None | False | 15878.48 | 0 | 3443585 | 122276 | None | code204 | Supplying&fixingminiaturecircuitbreakersonexistingMCBdistributionboardsusingnecessaryfixingmaterialsand'C'Typecurve,indicatorON/OFF,energycross- with Short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC60898 5.18.1)6-32Amps SP | Each | 427.45 | 427.45 | 75.0 | False | None | None | False | None | False | 32058.75 | 0 | 3443586 | 122276 | None | code205 | Supplying&fixingminiaturecircuitbreakersonexistingMCBdistributionboardsusingnecessaryfixingmaterialsand'C'Typecurve,indicatorON/OFF,energycross- with Short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC60898 5.18.4)6-32Amps DP | Each | 761.17 | 761.17 | 8.0 | False | None | None | False | None | False | 6089.36 | 0 | 3443587 | 122276 | None | code206 | GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg. Page No. 22, Sl No. 51.01 | No | 683.29 | 683.29 | 8.0 | False | None | None | False | None | False | 5466.32 | 0 | 3443588 | 122276 | None | code207 | Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each. Page No. 22, Sl No. 51.02 | No | 621.68 | 621.68 | 8.0 | False | None | None | False | None | False | 4973.44 | 0 | 3443589 | 122276 | None | code208 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag. Page No. 22, Sl No. 51.03 | Each | 285.09 | 285.09 | 8.0 | False | None | None | False | None | False | 2280.72 | 0 | 3443590 | 122276 | None | code209 | Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified. Page No. 23, Sl No. 51.04 | No | 1997.46 | 1997.46 | 8.0 | False | None | None | False | None | False | 15979.68 | 0 | 3443591 | 122276 | None | code210 | Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified. Page No. 23, Sl No. 51.05 | Each | 338.43 | 338.43 | 8.0 | False | None | None | False | None | False | 2707.44 | 0 | 3443592 | 122276 | None | code211 | Digging of Pit for providing GI Pipe type Earthing. In Ordinary Soil. Page No. 43, Sl No. 1.6.1 | Each | 781.77 | 781.77 | 6.0 | False | None | None | False | None | False | 4690.62 | 0 | 3443593 | 122276 | None | code212 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.. Guy Wire & GI Wire as per IS-2141. 8 SWG GI Wire (4.064 mm Dia), Std Wt: 125 Kg/KM | Tonne | 69010.0 | 69010.0 | 1.0 | False | None | None | False | None | False | 69010.0 | 0 | 3443594 | 122276 | None | code213 | Supply an fixing of …feet pvc batten with integrated led tube quality diffuser with life of 25000 burninng hours & 70% lumen maintance with CRI 80. power input :220-240V @ 50 hz & power factor .9 along with CE approved drivers. 2 years warranty. 11.3.1)LED light fitting 1x2' -9/10w | Each | 567.53 | 567.53 | 55.0 | False | None | None | False | None | False | 31214.15 | 0 | 3443595 | 122276 | None | code214 | Supply an fixing of …feet pvc batten with integrated led tube quality diffuser with life of 25000 burninng hours & 70% lumen maintance with CRI 80. power input :220-240V @ 50 hz & power factor .9 along with CE approved drivers. 2 years warranty. 11.3.2)LED light fitting 1x4' -20/22w | Each | 711.73 | 711.73 | 100.0 | False | None | None | False | None | False | 71173.0 | 0 | 3443596 | 122276 | None | code215 | Supplyofround /squarerecess/ surface mounted rolling type LED Downlight with......WGU10LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to main sconnector & hasswivelling unit of aluminium diecasteyeball & LED Lamp position retained by circular wirespring, with Life of 25000 burning hours & 70% lumenmaintenancewithCRI 80.PowerInput:220- 40V @50/60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition. 11.5.1)LED square or round down light 5-6W | Each | 588.13 | 588.13 | 10.0 | False | None | None | False | None | False | 5881.3 | 0 | 3443597 | 122276 | None | code216 | Supplyofround /squarerecess/ surface mounted rolling type LED Downlight with......WGU10LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to main sconnector & hasswivelling unit of aluminium diecasteyeball & LED Lamp position retained by circular wirespring, with Life of 25000 burning hours & 70% lumenmaintenancewithCRI 80.PowerInput:220- 40V @50/60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition. 11.5.3)LED square or round down light 15-18W | Each | 1363.72 | 1363.72 | 25.0 | False | None | None | False | None | False | 34093.0 | 0 | 3443598 | 122276 | None | code217 | Supplying exhaust fan of 1440 RPM of 300 mm (12'') size with bracket blades complete for light duty suitable for operate of 230V 50Hz, AC Supply 12" Sweep (300 mm) sl no 6.2.1 | Each | 3058.07 | 3058.07 | 30.0 | False | None | None | False | None | False | 91742.1 | 0 | 3443599 | 122276 | None | code218 | SupplyingofCeilingFanwithCapacitorratingAsperguidelineofBEE5starratingandIS:374/19andalsocomplywithIS:1709/1984withlatestamendment,Ratedvoltage220V/50Hz,Ratedpowerupto35W+/-10%,RatedcurrentAsperIS:374/19,Ratedpowerfactor0.9lagging(min),Ratedspeed350+/-10%RPM,Ratedairdelivery210+/-10%CubicMeterMinimum,Ratedservicevalue6.2CMM/W,ThreeBladesofbladeleaf1.05mmthickAluminiumAlloysheet,ClassBmotorinsulation,BearingTwoballbearings,Top6202,Bottom6201,asperISspecification,Motorwinding.TempriseShallnotexceed75degCoverandambientof400Cbyresistancemethodat245V,InsulationresistanceShallnotbelessthanTwoMegaOhms(2MOhms),LeakagecurrentShouldnotexceed210MicroAmp,Powerinput,W¤t,AirDelivery&FanSpeedasperIS:374/2019withlatestamendment,2yearmanufacturerWarranty.(BLDC fans Regular model (Khaitan, Crompton Greaves, Orient, Polar, Bajaj, Usha, Havells, Almonard) | Each | 2757.31 | 2757.31 | 75.0 | False | None | None | False | None | False | 206798.25 | 0 | 3443600 | 122276 | None | code219 | Supplying of LT UG cable having aluminium conductor PVC insulated, sheathed, galvanised, steel wire/steel tap armoured cable with PVC outer sheathing 1.1 KV class .1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 I.Class 'A' PVC Cable 35 Sqmm, 3.5 Core, (14 GI Strips - 4 x 0.8 mm) | Km | 141682.02 | 141682.02 | 0.75 | False | None | None | False | None | False | 106261.515 | 0 | 3443601 | 122276 | None | code220 | Supplying tinnd copper lugs and crimping and wiring to terminal point for wire of the following sizes. Heavy Duty Copper Terminal Long Barrel. 35 Sqmm Copper Terminal, Apprx Wt: 17 Gm | No | 36.79 | 36.79 | 8.0 | False | None | None | False | None | False | 294.32 | 0 | 3443602 | 122276 | None | code221 | Supplying and fixingof heavy duty cable glands suitable or UG cable o 1.1KV class (metal only). Page No. 28, Sl No. 63.02 32 mm dia | No | 87.37 | 87.37 | 8.0 | False | None | None | False | None | False | 698.96 | 0 | 3443603 | 122276 | None | code222 | Supply & fixing of aution/Danger name board as per drawing( BESCOM SR . CDS-1) Page No. 32, Sl No. 68.17 | No | 137.95 | 137.95 | 8.0 | False | None | None | False | None | False | 1103.6 | 0 | 3443604 | 122276 | None | code223 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. In ordinary. Page No. 8, Sl No. 29.02 | Cum | 267.8 | 267.8 | 787.5 | False | None | None | False | None | False | 210892.5 | 0 | 3443605 | 122276 | None | code224 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work In all kinds of soils. Depth upto 1.50m 1.6.1 vol-1 | Cum | 498.52 | 498.52 | 787.5 | False | None | None | False | None | False | 392584.5 | 0 | 3443606 | 122276 | None | code225 | PVC pipe-75mm dia (Page No 20of 40 Sl no:450). Page No. 15, Sl No. 48.07 | m | 147.14 | 147.14 | 100.0 | False | None | None | False | None | False | 14714.0 | 0 | 3443607 | 122276 | None | code226 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. Page No. 16, Sl No. 5.14 | Each | 10445.23 | 10445.23 | 7.0 | False | None | None | False | None | False | 73116.61 | 0 | 3443608 | 122276 | None | code227 | Supplying of multi function digital meter with three line back light LCD type display for voltage,Current,frequency,Power,Powerfactor,KVA,KWH,KVARsuitable for 3 Phase,4 wire LT network with IP 54 degree of protection and completely wired as required wuth communication Port and Class 0.5s accuracy. a)Group A | Each | 9594.45 | 9594.45 | 7.0 | False | None | None | False | None | False | 67161.15 | 0 | 3443609 | 122276 | None | code228 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.y FOUR Pole 5.14.7)100 A 25 kA | Each | 8512.95 | 8512.95 | 7.0 | False | None | None | False | None | False | 59590.65 | 0 | 3443610 | 122276 | None | code229 | Supplying,fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based,digital readout of percentage leakage current,programable delay/auto/manual reset facility suitable to mount on DIN rail/flush munting on panel board. 5.17.9)50-63Amps TPN | Each | 9532.65 | 9532.65 | 7.0 | False | None | None | False | None | False | 66728.55 | 0 | 3443611 | 122276 | None | code230 | Supplying, fixing and wiring 50/5A to 400/5A 5VA Burden class 1 Current Transformer. Page No. 19, Sl No. 5.34 a)Group A | Each | 578.86 | 578.86 | 7.0 | False | None | None | False | None | False | 4052.02 | 0 | 3443612 | 122276 | None | code231 | Supplying&fixingminiaturecircuitbreakersonexistingMCBdistributionboardsusingnecessaryfixingmaterialsand'C'Typecurve,indicatorON/OFF,energycross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirmingtoIEC60898.. 1 Group 'A' 5.18.8)40Amps TPN | Each | 3135.32 | 3135.32 | 7.0 | False | None | None | False | None | False | 21947.24 | 0 | 3443613 | 122276 | None | code232 | Supplying&fixingminiaturecircuitbreakersonexistingMCBdistributionboardsusingnecessaryfixingmaterialsand'C'Typecurve,indicatorON/OFF,energycross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirmingtoIEC60898.. 1 Group 'A' 5.18.9)50-63Amps TPN | Each | 3180.64 | 3180.64 | 5.0 | False | None | None | False | None | False | 15903.2 | 0 | 3443614 | 122276 | None | code233 | Supplying&fixingminiaturecircuitbreakersonexistingMCBdistributionboardsusingnecessaryfixingmaterialsand'C'Typecurve,indicatorON/OFF,energycross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirmingtoIEC60898.. 1 Group 'A' 5.18.5)40Amps DP | Each | 1091.8 | 1091.8 | 5.0 | False | None | None | False | None | False | 5459.0 | 0 | 3443615 | 122276 | None | code234 | Supplying&fixingminiaturecircuitbreakersonexistingMCBdistributionboardsusingnecessaryfixingmaterialsand'C'Typecurve,indicatorON/OFF,energycross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirmingtoIEC60898.. 1 Group 'A' 5.18.4)6-32Amps DP | Each | 761.17 | 761.17 | 5.0 | False | None | None | False | None | False | 3805.85 | 0 | 3443616 | 122276 | None | code235 | Supplying …..amps rated 3phase with netural bus bar using required capacity electrolytic alluminium strips covered with heat shrinkable coloured PVC sleeve,mounted on phenolic/ERP/DMC insulator which are mounted on powder coated 40x6 mm M.S.flat frame work in existing panel board.The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts,nuts and washers etc.,complete. 5.40.1)100 A 4 x 30 x 6 mm Aluminium Strips | m | 2538.95 | 2538.95 | 8.0 | False | None | None | False | None | False | 20311.6 | 0 | 3443617 | 122276 | None | code236 | FabricatingsupplyingandmountingMSboxmadeout....SWGsuitableforfloor/wallmounting,fullyweatherproofwithprovisionforbetterheatdissipation,providedwithhingedfrontcover,equippedwithtamperprooflockingarrangements,withsuitablesizeclampswithnecessarycableentrypipewithglandandboxshouldbefinishedwith7tankstreatmentwithpowdercoatedpaintand finally finished with approved colour etc., complete. 5.42.1)14SWG | Sq CM | 0.52 | 0.52 | 15000.0 | False | None | None | False | None | False | 7800.0 | 0 | 3443618 | 122276 | None | code237 | FabricatingsupplyingandmountingMSboxmadeout....SWGsuitableforfloor/wallmounting,fullyweatherproofwithprovisionforbetterheatdissipation,providedwithhingedfrontcover,equippedwithtamperprooflockingarrangements,withsuitablesizeclampswithnecessarycableentrypipewithglandandboxshouldbefinishedwith7tankstreatmentwithpowdercoatedpaintand finally finished with approved colour etc., complete. 5.42.2)16SWG | Sq CM | 0.44 | 0.44 | 60000.0 | False | None | None | False | None | False | 26400.0 | 0 | 3443619 | 122276 | None | code238 | Supplying and fixing of LED type pannel board indicating lamp with reqired colour suitable for 230/440 V A.C.50 Hz 12/24v D.C. Page No. 19, Sl No. 5.38 a)Group A | Each | 530.45 | 530.45 | 12.0 | False | None | None | False | None | False | 6365.4 | 0 | 3443620 | 122276 | None | code239 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.. Page No. 20, Sl No. 5.41 5.41.1)40 x 40 x 6 mm | m | 314.15 | 314.15 | 10.0 | False | None | None | False | None | False | 3141.5 | 0 | 3443621 | 122276 | None | code240 | Supplying and drawing UTP-CAT 6E LAN cable. Page No. 36, Sl No. 8.1 | m | 39.14 | 39.14 | 950.0 | False | None | None | False | None | False | 37183.0 | 0 | 3443622 | 122276 | None | code241 | Supplying, erecting, testing & commissioning of OFF-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with all accessories complete and Excluding batteries and wiring complete...5KVA OFF LINE UPS Two Hour back up Excluding 6x 60Ah batteries. Page No. 38, Sl No. 9.2.5 | Each | 41094.94 | 41094.94 | 5.0 | False | None | None | False | None | False | 205474.7 | 0 | 3443623 | 122276 | None | code242 | 12 V 60 / 65 AH capacity CAPACTIY ACID BATTERY. Page No. 38, Sl No. 9.2.5 | Each | 41094.94 | 41094.94 | 15.0 | False | None | None | False | None | False | 616424.1 | 0 | 3443624 | 122276 | None | code243 | Arrange for the 1 energy metera, CHSCOM deposit, laisening work and including road cutting permission, etc. Page No. 28, nt | LS | 20600.0 | 20600.0 | 6.0 | False | None | None | False | None | False | 123600.0 | 0 |
|