| 1720591776000 | 0 | None | None | Buildings | Construction of Dry Waste Collection Center in the solid waste disposal unit of Mulbagal Town | 1270336.56 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3501148 | 125141 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m [PWD SR 2023-24 Vol:1 P.NO.8 I.No:1.14.1] | Cum | 105.06 | 105.06 | 80.73 | False | None | None | False | None | False | 8481.4938 | 0 | | 3501149 | 125141 | None | code02 | PCC (1:4:8) Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates [PWD SR 2023-24 Vol:I P.NO.15 I.No:2.1.3] | Cum | 5833.92 | 5833.92 | 33.84 | False | None | None | False | None | False | 197419.8528 | 0 | | 3501150 | 125141 | None | code03 | RCC (M20) Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub-structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).M20 Design Mix Using 20 mm nominal size gradedcrushed coarse aggregates [PWD SR 2023-24 Vol:1 P.NO.16 I.No:2.4.2] For Plinth Beam considered 50% | Cum | 7815.23 | 7815.23 | 29.21 | False | None | None | False | None | False | 228282.8683 | 0 | | 3501151 | 125141 | None | code04 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification [PWD SR 2023-24 Vol:1 P.NO.18 I.No: 2.11a] | Tonne | 78667.28 | 78667.28 | 2.0 | False | None | None | False | None | False | 157334.56 | 0 | | 3501152 | 125141 | None | code05 | Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge.[PWD SR 2023-24 Vol:2 P.NO.77 I.No: 11.2] | Kg | 116.39 | 116.39 | 2697.2 | False | None | None | False | None | False | 313927.108 | 0 | | 3501153 | 125141 | None | code06 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(Page No17, Item No 6.4 Vol-2) PWD 2023-24 SR | Sq CM | 1267.93 | 1267.93 | 70.0 | False | None | None | False | None | False | 88755.1 | 0 | | 3501154 | 125141 | None | code07 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required nsmooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge(Page No41, Item No 8.3.1 Vol-2) PWD 2023-24 SR. | Sq CM | 364.62 | 364.62 | 150.0 | False | None | None | False | None | False | 54693.0 | 0 | | 3501155 | 125141 | None | code08 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life)[PWD SR 2023-24 Vol:2 P.NO.46 I.No: 8.33.1] | Sq CM | 162.74 | 162.74 | 150.0 | False | None | None | False | None | False | 24411.0 | 0 | | 3501156 | 125141 | None | code09 | Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and s.[PWD SR 2023-24 Vol:2 P.NO.77 I.No: 11.2]0.63 mm thick with zinc coating not less than 275 g/ m² | Sq CM | 905.37 | 905.37 | 175.2 | False | None | None | False | None | False | 158620.824 | 0 | | 3501157 | 125141 | None | code10 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3 orners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge[PWD SR 2023-24 Vol:2 P.NO.77I.No:11.51 ] | Sq CM | 4612.34 | 4612.34 | 5.0 | False | None | None | False | None | False | 23061.7 | 0 | | 3501158 | 125141 | None | code11 | Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thickconfirming to IS 2509 with suitable size bends, metal/PVC Junctionboxes, adhesive paste etc., and running before concreting the slab. Theconduit should be tied to the reinforcement rods by using bindingwires and unused ways of junction boxes and pipe ends should becovered using PVC end enclosures, run with 18SWG GI fish wirewherever necessary 25 mm dia 2 mm thick[PWD ELECTRICAL SR 2023-24 part-1 Vol:3 P.NO.46 I.No:14.03] | Mtr | 80.34 | 80.34 | 90.0 | False | None | None | False | None | False | 7230.6 | 0 | | 3501159 | 125141 | None | code12 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010 4mm 2[PWD ELECTRICAL SR 2023-24 part-1 Vol:3 P.NO.5 I.No:2.3.4] | Mtr | 64.89 | 64.89 | 90.0 | False | None | None | False | None | False | 5840.1 | 0 | | 3501160 | 125141 | None | code13 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. | Each | 123.6 | 123.6 | 3.0 | False | None | None | False | None | False | 370.8 | 0 | | 3501161 | 125141 | None | code14 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal / PVC box. 4 Module-75 x 75 x 65 mm | Each | 109.18 | 109.18 | 1.0 | False | None | None | False | None | False | 109.18 | 0 | | 3501162 | 125141 | None | code15 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal / PVC box. 4 Module-135 x 75 x 65 mm | Each | 143.17 | 143.17 | 2.0 | False | None | None | False | None | False | 286.34 | 0 | | 3501163 | 125141 | None | code16 | supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6/16A Universal Socket | Each | 250.29 | 250.29 | 3.0 | False | None | None | False | None | False | 750.87 | 0 | | 3501164 | 125141 | None | code17 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A DP | Each | 761.17 | 761.17 | 1.0 | False | None | None | False | None | False | 761.17 | 0 |
|