| 1720513934000 | 0 | None | None | Buildings | Construction of Community Toilet at Sunagar Oni in TP Limit of Kerur | 1268292.9 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3495646 | 124834 | None | 001 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work (Item No.1.14.1 page no.8 Vol.1 2023-24) | Cum | 105.06 | 105.06 | 81.86 | False | None | None | False | None | False | 8600.2116 | 0 | | 3495647 | 124834 | None | 002 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.(Item No.2.1.2 page no.15 Vol.1 2023-24)Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates
(Item No.2.1.2page no.15 Vol.1 2023-24) | Cum | 5833.92 | 5833.92 | 13.83 | False | None | None | False | None | False | 80683.1136 | 0 | | 3495648 | 124834 | None | 003 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
(Item No.2.3.1page no.15 Vol.1 2023-24) | Cum | 6828.84 | 6828.84 | 18.28 | False | None | None | False | None | False | 124831.1952 | 0 | | 3495649 | 124834 | None | 004 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.
(Item No.2.11page no.18Vol.1 2023-24) | Cum | 92.14 | 92.14 | 1645.64 | False | None | None | False | None | False | 151629.2696 | 0 | | 3495650 | 124834 | None | 005 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications (Item No.6.33page no.17Vol.2 2023-24) | Sqm | 1267.93 | 1267.93 | 165.19 | False | None | None | False | None | False | 209449.3567 | 0 | | 3495651 | 124834 | None | 006 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand)(Item No.5.11page no.9Vol.2 2023-24) | Cum | 5779.33 | 5779.33 | 1.08 | False | None | None | False | None | False | 6241.6764 | 0 | | 3495652 | 124834 | None | 007 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates (Item No.2.1.6page no.15 Vol.1 2023-24) | Cum | 6430.29 | 6430.29 | 5.0 | False | None | None | False | None | False | 32151.45 | 0 | | 3495653 | 124834 | None | 008 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Item No.8.2.1page no.41Vol.2 2023-24) | Sqm | 303.85 | 303.85 | 319.1 | False | None | None | False | None | False | 96958.535 | 0 | | 3495654 | 124834 | None | 009 | Providing and fixing 10 mm thick acid and/or alkali resistant tiles of ap- proved make and colour using acid and/or alkali resisting mortar bedding for Bathrooms: Toilet: Chemically exposed areas and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direc- tion of Engineer-in- Charge.In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) with Acid and alkali resistant tile
(Item No.9.7.1page no.59Vol.2 2023-24) | Sqm | 1283.38 | 1283.38 | 24.56 | False | None | None | False | None | False | 31519.8128 | 0 | | 3495655 | 124834 | None | 010 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.
Item No.9.3.8page no.65Vol.2 2023-24) | Sqm | 1433.76 | 1433.76 | 76.05 | False | None | None | False | None | False | 109037.448 | 0 | | 3495656 | 124834 | None | 011 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame Item No12.96page no.112Vol.2 2023-24) | Sqm | 662.29 | 662.29 | 57.0 | False | None | None | False | None | False | 37750.53 | 0 | | 3495657 | 124834 | None | 012 | Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.
(Item No12.96page no.112Vol.2 2023-24) | Sqm | 3300.12 | 3300.12 | 15.75 | False | None | None | False | None | False | 51976.89 | 0 | | 3495658 | 124834 | None | 013 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
Item No11.12page no.80Vol.2 2023-24) | Sqm | 110.21 | 110.21 | 108.0 | False | None | None | False | None | False | 11902.68 | 0 | | 3495659 | 124834 | None | 014 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
Item No11.12page no.80Vol.2 2023-24) | Each | 5030.52 | 5030.52 | 8.0 | False | None | None | False | None | False | 40244.16 | 0 | | 3495660 | 124834 | None | 015 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required ItemW.C. pan with ISI marked white solid plastic seat and lid
( Item No14.2.1page no.131Vol.2 2023-24) | Each | 4983.14 | 4983.14 | 1.0 | False | None | None | False | None | False | 4983.14 | 0 | | 3495661 | 124834 | None | 016 | Providing and fixing wash basin with C.I. brackets, 15 mm PTMT pillar cock, 32 mm PTMT waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm PTMT pillar cock.
( Item No14.7Apage no.133Vol.2 2023-24) | Each | 2364.88 | 2364.88 | 1.0 | False | None | None | False | None | False | 2364.88 | 0 | | 3495662 | 124834 | None | 017 | Providing and fixing P.V.C. waste pipe for sink or wash basin including
P.V.C. waste fittings completeFlexible pipe ( Item No14.28.2.1page no.136Vol.2 2023-24) | Each | 94.76 | 94.76 | 1.0 | False | None | None | False | None | False | 94.76 | 0 | | 3495663 | 124834 | None | 018 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand
: 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5
( Item No13.53.1page no.126Vol.2 2023-24) | Each | 5811.26 | 5811.26 | 11.0 | False | None | None | False | None | False | 63923.86 | 0 | | 3495664 | 124834 | None | 019 | Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete ( Item No13.59page no.127Vol.2 2023-24) | Each | 226.6 | 226.6 | 3.0 | False | None | None | False | None | False | 679.8 | 0 | | 3495665 | 124834 | None | 020 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
( Item No13.34page no.123Vol.2 2023-24) | Each | 9.27 | 9.27 | 2000.0 | False | None | None | False | None | False | 18540.0 | 0 | | 3495666 | 124834 | None | 021 | Providing and fixing PTMT bib cock of approved quality and colour.
( Item No13.17.1page no.120Vol.2 2023-24) | Each | 162.74 | 162.74 | 11.0 | False | None | None | False | None | False | 1790.14 | 0 | | 3495667 | 124834 | None | 022 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at
1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall15 mm nominal dia Pipes
( Item No13.31.1page no.120Vol.2 2023-24) | m | 187.46 | 187.46 | 40.0 | False | None | None | False | None | False | 7498.4 | 0 | | 3495668 | 124834 | None | 023 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at
1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work -25 mm nominal dia Pipes
( Item No13.31.3page no.120Vol.2 2023-24) | m | 327.54 | 327.54 | 25.0 | False | None | None | False | None | False | 8188.5 | 0 | | 3495669 | 124834 | None | 024 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at
1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work -40 mm nominal dia Pipes
( Item No13.31.5page no.120Vol.2 2023-24) | m | 552.08 | 552.08 | 50.0 | False | None | None | False | None | False | 27604.0 | 0 | | 3495670 | 124834 | None | 025 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work
-100 mm nominal dia Pipes
( Item No13.50.9page no.125Vol.2 2023-24) | m | 957.9 | 957.9 | 50.0 | False | None | None | False | None | False | 47895.0 | 0 | | 3495671 | 124834 | None | 026 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 75 mm diameter
( Item No13.479page no.125Vol.2 2023-24) | m | 202.91 | 202.91 | 13.5 | False | None | None | False | None | False | 2739.285 | 0 | | 3495672 | 124834 | None | 027 | Providing and laying brick bats for soak pit
( Sl No137page no.A-15Vol.2 2023-24) | Cum | 824.0 | 824.0 | 9.0 | False | None | None | False | None | False | 7416.0 | 0 | | 3495673 | 124834 | None | 028 | Providing and laying coarse sand for soak pit
( Sl No239page no.A-19Vol.2 2023-24) | Cum | 844.6 | 844.6 | 3.6 | False | None | None | False | None | False | 3040.56 | 0 | | 3495674 | 124834 | None | 029 | Providing and laying granular aggregates for soak pit
( Sl No7page no.A-38Vol.1 2023-24) | Cum | 1225.7 | 1225.7 | 7.65 | False | None | None | False | None | False | 9376.605 | 0 | | 3495675 | 124834 | None | 030 | Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work
Item no1.8page no.7Vol.1 2023-24) | Cum | 488.22 | 488.22 | 19.19 | False | None | None | False | None | False | 9368.9418 | 0 | | 3495676 | 124834 | None | 031 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.
Item no8.54.1page no.50Vol.2 2023-24) | Sqm | 75.19 | 75.19 | 150.0 | False | None | None | False | None | False | 11278.5 | 0 | | 3495677 | 124834 | None | 032 | Finishing walls with Premium Acrylic Smooth exterior paint of required shade : Old work (one coats applied @ 0.83 l/10 m²) including preparing the surface after thoroughly cleaning the surface to remove all dirt,dust and foreign matter , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
Item no8.75.2page no.53Vol.2 2023-24) | Sqm | 75.19 | 75.19 | 180.0 | False | None | None | False | None | False | 13534.2 | 0 | | 3495678 | 124834 | None | 033 | Internal electrifiction and hescom meter charges and external wiring/cabling upto electrical pole and commissioning of interior and exterior lighting | No | 35000.0 | 35000.0 | 1.0 | False | None | None | False | None | False | 35000.0 | 0 |
|