3511452 | 125805 | None | code01 | Construction Of 01 Class Rooms to Governement Higher Primary School in Bailuvaddigeri Village in, hospet Tq Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work Depth exceeding 1.5 m, but not exceeding 3 m | Cum | 654.15 | 654.15 | 1.73 | False | None | None | False | None | False | 1131.6795 | 0 |
3511453 | 125805 | None | code02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/ trap / basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6123.6 | 6123.6 | 10.46 | False | None | None | False | None | False | 64052.856 | 0 |
3511454 | 125805 | None | code03 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6941.24 | 6941.24 | 0.22 | False | None | None | False | None | False | 1527.0728 | 0 |
3511455 | 125805 | None | code04 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 12323.64 | 12323.64 | 5.5 | False | None | None | False | None | False | 67780.02 | 0 |
3511456 | 125805 | None | code05 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11598.72 | 11598.72 | 11.21 | False | None | None | False | None | False | 130021.6512 | 0 |
3511457 | 125805 | None | code06 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of
engineer incharge of work | Cum | 8621.55 | 8621.55 | 26.06 | False | None | None | False | None | False | 224677.593 | 0 |
3511458 | 125805 | None | code07 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 10095.7 | 10095.7 | 0.23 | False | None | None | False | None | False | 2322.011 | 0 |
3511459 | 125805 | None | code08 | Supplying, Fitting and Placing TMT Fe 500 & above Reinforcement in Foundation/Substructure/Superstructure complete as per Drawing and Technical Specifications. | Tonne | 93929.85 | 93929.85 | 1.83 | False | None | None | False | None | False | 171891.6255 | 0 |
3511460 | 125805 | None | code09 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications | Cum | 144977.7 | 144977.7 | 0.14 | False | None | None | False | None | False | 20296.878 | 0 |
3511461 | 125805 | None | code10 | Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) | Sqm | 7816.2 | 7816.2 | 5.04 | False | None | None | False | None | False | 39393.648 | 0 |
3511462 | 125805 | None | code11 | Providing and fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC Matching to RAL-9016) sections and with minimum TiO2 Titanium 6PHR with TPE Plastic and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass standard hardware Multi point locking system with touch lock. | Sqm | 7070.7 | 7070.7 | 4.32 | False | None | None | False | None | False | 30545.424 | 0 |
3511463 | 125805 | None | code12 | Providing and fixing hand rail of approved size by welding etc. to
steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 136.5 | 136.5 | 630.0 | False | None | None | False | None | False | 85995.0 | 0 |
3511464 | 125805 | None | code13 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 334.69 | 334.69 | 83.49 | False | None | None | False | None | False | 27943.2681 | 0 |
3511465 | 125805 | None | code14 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 423.94 | 423.94 | 240.89 | False | None | None | False | None | False | 102122.9066 | 0 |
3511466 | 125805 | None | code15 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete | Sqm | 1202.25 | 1202.25 | 84.74 | False | None | None | False | None | False | 101878.665 | 0 |
3511467 | 125805 | None | code16 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. | Sqm | 1993.95 | 1993.95 | 65.17 | False | None | None | False | None | False | 129945.7215 | 0 |
3511468 | 125805 | None | code17 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 172.62 | 172.62 | 272.44 | False | None | None | False | None | False | 47028.5928 | 0 |
3511469 | 125805 | None | code18 | Finishing walls with textured exterior paint of required shade : New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 356.58 | 356.58 | 326.13 | False | None | None | False | None | False | 116291.4354 | 0 |
3511470 | 125805 | None | code19 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 175.14 | 175.14 | 7.92 | False | None | None | False | None | False | 1387.1088 | 0 |
3511471 | 125805 | None | code20 | Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | cm | 4.2 | 4.2 | 2000.0 | False | None | None | False | None | False | 8400.0 | 0 |
3511472 | 125805 | None | code21 | Concealed Conduit System : Supplying 19/20 mm dia 2 mm 2.5 mm thick heavy gauge PVC conduit pipe with suitable size bends metal / PC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18 SWG GI fish wire wherever necessary. | Mtr | 66.0 | 66.0 | 50.0 | False | None | None | False | None | False | 3300.0 | 0 |
3511473 | 125805 | None | code22 | Point wiring using copper wire with switch Supplying and wiring adopting loop system in existing PVC Conduit /casing caping using copper PVC insulated multi strand 2x1.5Sqmm copper wire with a 6Amps flush type SP control switch shall be fixed on the exisiting plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet.Point wiring using class A Materials: for Short point upto 3Mtr from tapping point to out let via switch Item No. 2.1, Page No.5.and as per directed by Engineer Incharge of Work.a. Long point from 6mtr to 10 Mtr from tapping to via switch | Mtr | 394.0 | 394.0 | 3.0 | False | None | None | False | None | False | 1182.0 | 0 |
3511474 | 125805 | None | code23 | Wiring for lighting/power circuit using one of PVC insulated 1100v grade multis and Copper conductor single core cable in open or consealed system of wiring as per IS-694:1990 & confirming to GTP of Group-B . Group B Materials and as per directed by Engineer Incharge of Work.c.6 Sqmm | Mtr | 117.0 | 117.0 | 50.0 | False | None | None | False | None | False | 5850.0 | 0 |
3511475 | 125805 | None | code24 | Supplying Patti type Flourcent tube light fitting of 2' suitable for 14 watts flour cent tube fitting made out of M.S. Sheet and stove enameled with loss open construction copper wound ferromagnetic ballast starter locking type brass contract holders moulded on double fold type sheet base fully wired to use on 230 volts AC supply including T5 lamp. Item No.4.5, Page no.20.and as per directed by Engineer Incharge of Work. | Mtr | 1269.0 | 1269.0 | 2.0 | False | None | None | False | None | False | 2538.0 | 0 |
3511476 | 125805 | None | code25 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating andI S: 374/79 and alsocomply with IS: 1709/1984 with latest amendment Rated voltage220V/50 Hz, Rated power input 48W+/-10%,Rated current As per IS:374/79, Rated power factor 0.9l agging (min), Rated speed 350+/-10%RPM, Rated airdelivery 210+/-10% Cubic Meter Minimum, Rated service value 4.2 CMM /W,Three Blade sofblade leaf 1.05mm thick Aluminium Alloy sheet, Class B motor insulation ,210Micro Amp, Power input,W¤t, Air Delivery & Fan Speed asperIS:374/1979 with latest amendment, 2year manufacturerWarranty. | Each | 2677.0 | 2677.0 | 2.0 | False | None | None | False | None | False | 5354.0 | 0 |
3511477 | 125805 | None | code26 | Supplying and fixing PVC / metal conduit accessories Deep type junction box a) 19/20 mm dia 2 mm thick | Each | 49.0 | 49.0 | 1.0 | False | None | None | False | None | False | 49.0 | 0 |
3511478 | 125805 | None | code27 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, necessary masonry patch work complete a) 12"x12x3" (300x300x76 mm) | Each | 120.0 | 120.0 | 3.0 | False | None | None | False | None | False | 360.0 | 0 |
3511479 | 125805 | None | code28 | Point wiring using copper wire with switch Supplying and wiring adopting loop system in existing PVC conduit / casing caping using copper PVC insulated multi strand 2x1 5 sqmm copper wire with a 6 Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shaft be terminated with sufficient boose length in a wood / PVC round block complete for each outlet. a) Shoft point upto 3 Mtr from tapping point to outlet via switch | Each | 285.0 | 285.0 | 2.0 | False | None | None | False | None | False | 570.0 | 0 |
3511480 | 125805 | None | code29 | Point wiring using copper wire with switch Supplying and wiring adopting loop system in existing PVC conduit / casing caping using copper PVC insulated multi strand 2x1 5 sqmm copper wire with a 6 Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shaft be terminated with sufficient boose length in a wood / PVC round block complete for each outlet. b) Medium point upto 3 Mtr from tapping point to outlet via switch | Each | 379.0 | 379.0 | 2.0 | False | None | None | False | None | False | 758.0 | 0 |
3511481 | 125805 | None | code30 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator dimmer / telephone socket etc on existing modular switch plate. | Each | 102.0 | 102.0 | 2.0 | False | None | None | False | None | False | 204.0 | 0 |
3511482 | 125805 | None | code31 | Supplying and fixing 3 mm thick hylum plastic sheet etc complete with necessary nitches and screws etc complete. | Each | 0.41 | 0.41 | 276.0 | False | None | None | False | None | False | 113.16 | 0 |