createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1720358594805
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd11125.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose24-07-2024 11:00:00
tenderQueryClose23-07-2024 11:00:00
technicalBidOpen26-07-2024 11:00:00
publishedDate11-07-2024 19:00:20
publishedByPostTP_CO_CNCH
publishedByUserKPE13765 - VENKATSWAMI BALLARI
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonVenkatswami Ballari
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber8050458150
tenderSupplierListNone
tenderSchedule
createdTs1720358594839
version4
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/WS/WORK_INDENT20897
titleDrilling a new Borewell and installing a new motor pump set at near Sunil Kavale House Adjacent to Malwada Road in Ward No.08 and Constructing a cistern water tank and installing a pipeline Near Ningappa Kakhiguddi house. 2 Construction of Cistern water tank and installation of pipeline inWard No. 10 near Mallu Pirannavara, Aneela Dandapure, Santhosh Patila, houses
descriptionDrilling a new Borewell and installing a new motor pump set at near Sunil Kavale House Adjacent to Malwada Road in Ward No.08 and Constructing a cistern water tank and installing a pipeline Near Ningappa Kakhiguddi house. 2 Construction of Cistern water tank and installation of pipeline inWard No. 10 near Mallu Pirannavara, Aneela Dandapure, Santhosh Patila, houses
categoryWORKS
categoryTextWorks
ecv450000.00
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2513
locationNameDMA Town Panchayat Chinchali
provisionalAmount450000.0
groupOverheadTotal72087.14
fileNumberCHL/15thFC/2024-25/03
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17203585950000NoneNoneWater supply/sewage lines1 Drilling a new Borewell and installing a new motor pump set at near Sunil Kavale House Adjacent to Malwada Road in Ward No.08 and Constructing a cistern water tank and installing a pipeline Near Ningappa Kakhiguddi house. 2 Construction of Cistern water tank and installation of pipeline inWard No. 10 near Mallu Pirannavara, Aneela Dandapure, Santhosh Patila, houses377912.86
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3473150124029Nonecode01Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 0 to 50 Mtrs PWD CSR Water supply and sewerage works 2023-24 Volume 5 (P No: 139 I.No: 12.1.1) Rate 370.00+5%=388.50Mtr388.5388.550.0FalseNoneNoneFalseNoneFalse19425.00
3473151124029Nonecode02Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 50 to 100 Mtrs PWD CSR Water supply and sewerage works 2023-24 Volume 5 (P No: 139 I.No: 12.1.2) Rate 464.00+5%=487.20Mtr487.2487.250.0FalseNoneNoneFalseNoneFalse24360.00
3473152124029Nonecode03Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 100 to150 Mtrs PWD CSR Water supply and sewerage works 2023-24 Volume 5 (P No: 139 I.No: 12.1.3) Rate 493.00+5%=517.65Mtr517.65517.6520.0FalseNoneNoneFalseNoneFalse10353.00
3473153124029Nonecode04Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. etc. complete PWD CSR Water supply and sewerage works 2023-24 Volume 5 (P No: 141 I.No: 12.4) Rate 5288.00+5%=5552.40Each5552.45552.41.0FalseNoneNoneFalseNoneFalse5552.40
3473154124029Nonecode05Supply of ISI mark 175mm nominal bore, plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends. threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m. prices include Collar-Medium duty. PWD CSR Water supply and sewerage works 2023-24 Volume 5 (P No: 143 I.No: 12.32) Rate 1933.00+5%=2029.65Mtr2029.652029.656.0FalseNoneNoneFalseNoneFalse12177.90
3473155124029Nonecode06Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and collars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments PWD CSR Water supply and sewerage works 2023-24 Volume 5 (P No: 143 I.No: 12.33) Rate 150.00+5%=157.50Each157.5157.51.0FalseNoneNoneFalseNoneFalse157.50
3473156124029Nonecode07Providing and laying at site of work MS casing caps as per IS 1239 (part- II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge PWD CSR Water supply and sewerage works 2023-24 Volume 5 (P No: 143 I.No: 12.34) Rate 164.00+5%=172.20Each172.2172.21.0FalseNoneNoneFalseNoneFalse172.20
3473157124029Nonecode08Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary amendments and instructions of engineer incharge of work. For 3 HP etc. complete 3.00 HP - 135 LPM @ 56 m = 8 STG Outlet Dia - 2.00" PWD CSR Water supply and sewerage works 2023-24 Volume 5 (P No: 151 I.No: 13.11.3) Rate 25910.00+5%=27205.50Each27205.527205.51.0FalseNoneNoneFalseNoneFalse27205.50
3473158124029Nonecode09Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x2.5 m2 PWD CSR Water supply and sewerage works 2023-24 Volume 5 (P No: 154 I.No: 13.22.2) Rate 85.00+5%=89.25Mtr89.2589.2590.0FalseNoneNoneFalseNoneFalse8032.50
3473159124029Nonecode10Supply and delivery at site of brand new best make gate valve as per IS778/1984 with ISI Mark and as per its latest amendments Size 50 mm PWD CSR Water supply and sewerage works 2023-24 Volume 5 (P No: 154 I.No: 13.24.1) Rate 1250.00+5%=1312.50Each1312.51312.51.0FalseNoneNoneFalseNoneFalse1312.50
3473160124029Nonecode11Supply, installing, testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete. 3 to 6 HP pumps PWD CSR Water supply and sewerage works 2023-24 Volume 5 (P No: 151 I.No: 13.23.2) Rate 9550.00+5%=10027.5Each10027.510027.51.0FalseNoneNoneFalseNoneFalse10027.50
3473161124029Nonecode12Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box. PWD CSR Water supply and sewerage works 2023-24 Volume 5 (P No: 155 I.No: 13.26) Rate 1150.00+5%=1207.50Per 3 Poles1207.51207.51.0FalseNoneNoneFalseNoneFalse1207.50
3473162124029Nonecode13Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars, rubber profile ring, vibration control profile ring, freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments PWD CSR Water supply and sewerage works 2023-24 Volume 5 (P No: 155 I.No: 13.28) Rate 550.00+5%=577.50Mtr577.5577.580.0FalseNoneNoneFalseNoneFalse46200.00
3473163124029Nonecode14Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for UPVC Column pipes for Submersible pump sets PWD CSR Water supply and sewerage works 2023-24 Volume 5 (P No: 155 I.No: 13.29) Rate 1550.00+5%=1627.50Set1627.51627.51.0FalseNoneNoneFalseNoneFalse1627.50
3473164124029Nonecode15Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. PWD CSR Water supply and sewerage works 2023-24 Volume 5 (P No: 156 I.No: 13.32) Rate 6500.00+5%=6825.00Job6825.06825.01.0FalseNoneNoneFalseNoneFalse6825.00
3473165124029Nonecode16Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer incharge of work. PWD CSR Water supply and sewerage works 2023-24 Volume 5 (P No: 156 I.No: 13.34) Rate 1450.00+5%=1522.50Job1522.51522.51.0FalseNoneNoneFalseNoneFalse1522.50
3473166124029Nonecode17Providing, Supplying and fixing suitable for 1.1 KV class UG cable filled with necessary bitumen/insulating compound complete with terminals, clamps ,bolts, nuts and washers etc. with necessary materials and labour tools and equipments as per instructions of engineer in charge of work. 3x6 Sqm PWD CSR Water supply and sewerage works 2023-24 Volume 5 (P No: 156 I.No: 13.38.1) Rate 375.00+5%=393.75Each393.75393.751.0FalseNoneNoneFalseNoneFalse393.750
3473167124029Nonecode18Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia PWD CSR Water supply and sewerage works 2023-24 Volume 5 (P No: 156 I.No: 13.39) Rate 3750.00+5%=3937.50Job3937.53937.51.0FalseNoneNoneFalseNoneFalse3937.50
3473168124029Nonecode19Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m PWD common SR 2023-24 Volume 1 (P No: 5 I.No: 1.4.1) . Rate 242.00+5%=254.10Cum254.1254.146.7775FalseNoneNoneFalseNoneFalse11886.162750
3473169124029Nonecode20Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. M 10 Grade Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates PWD Common DSR 2023-24 Volume 1 (P No: 15 I.No:2.1.3 )Rate 5989.00 +5%=6288.45Cum6288.456288.450.9FalseNoneNoneFalseNoneFalse5659.6050
3473170124029Nonecode21Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) PWD building DSR 2023-24 Volume 2 (P No: 9 I.No:5.1.1 )Rate 5,611.00+5%=5891.55Cum5891.555891.558.8875FalseNoneNoneFalseNoneFalse52361.1506250
3473171124029Nonecode22Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD Common DSR 2023-24 Volume 1 (P No: 16 I.No:2.3.1) Rate 6323.00+5%=6639.15Cum6639.156639.150.928FalseNoneNoneFalseNoneFalse6161.13120
3473172124029Nonecode23Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. PWD building DSR 2023-24 Volume 2 (P No: 41 I.No:8.1.2 )Rate 241.00+5%=253.05Sqm253.05253.0510.8FalseNoneNoneFalseNoneFalse2732.940
3473173124029Nonecode24Providing S&S RCC SPUN / VIBRATED CAST PIPES (REINFORCED) pipes NP-3 Class conforming to IS:458-1988 with latest amendments using ordinary portland cement, for sanitary works and conveying to work site, rolling and lowering into trenches, laying true to line and level including loading and unloading at both destinations and jointing of pipes and specials, perfect linking of joints with jack to correct position including cost of jointing materials, i.e, rubber rings conforming to IS: 5382 for S&S RCC pipes, with all leads and lifts as directed and giving necessary hydraulic test as per ISS to the required pressure and commissioning etc. complete. (Contractor will make his own arrangements for procuring water for testing). Before the execution of the work, the contractor shall carry out the survey. RCC NP3 Class pipe of 1200 mm dia. PWD CSR Water supply and sewerage works 2023-24 Volume 5 (P No: 188 I.No: 16.3.13) Rate 9345.00+5%=9812.25Each9812.259812.254.0FalseNoneNoneFalseNoneFalse39249.00
3473174124029Nonecode25Erection and positioning of RCC Hume pipe pump house/Cistern on size stone masory platform including transportation charges and handling, finishing with all necessary tools ,plants and materials etc., complete as directed by the Engineer in charge of the work. PWD CSR Water supply and sewerage works 2023-24 Volume 5 (P No: 116 I.No: 10.7) Rate 1882.00+5%=1976.10Each1976.11976.14.0FalseNoneNoneFalseNoneFalse7904.40
3473175124029Nonecode26Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing)Medium Duty GI pipe of 50mm dia PWD CSR Water supply and sewerage works 2023-24 Volume 5 (P No: 127 I.No: 11.2.6) Rate 584.00+5%=613.20Mtr613.2613.23.599FalseNoneNoneFalseNoneFalse2206.90680
3473176124029Nonecode27Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing)Medium Duty GI pipe of 20mm dia PWD CSR Water supply and sewerage works 2023-24 Volume 5 (P No: 127 I.No: 11.2.2) Rate 245.00+5%=257.25Mtr257.25257.253.6FalseNoneNoneFalseNoneFalse926.10
3473177124029Nonecode28Providing wrought mild steel (galvanized) 20 mm dia GI collar confirming to IS 1239-II, 1991 with latest amendments if any.)For 20 mm dia GI collar:PWD CSR Water supply and sewerage works 2023-24 Volume 5 (P No: 129 I.No: 11.6.2) Rate 99.00+5%=103.95Each103.95103.958.0FalseNoneNoneFalseNoneFalse831.60
3473178124029Nonecode29Providing and fixing PTMT bib cock of approved quality and colour. 15mm nominal bore, 86 mm long, weighing not less than 88 g PWD Building DSR 2021-22 Volume 2 (P No: 118 I.No: 13.17.1)Rate 148.00+5%=155.40Each155.4155.48.0FalseNoneNoneFalseNoneFalse1243.20
3473179124029Nonecode30Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 63mm dia., 6 kg/sqcm & class 3 PWD CSR Water supply and sewerage works 2023-24 Volume 5 (P No: 113 I.No: 10.1.4) Rate 161.00+5%=169.05Mtr169.05169.05330.0FalseNoneNoneFalseNoneFalse55786.50
3473180124029Nonecode31Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications PWD common SR 2023-24Volume 1 (P No: 5 I.No: 1.4.1) . Rate 160.00+5%=168.00Cum168.0168.042.38FalseNoneNoneFalseNoneFalse7119.840
3473181124029Nonecode32Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thin able priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. PWD building DSR 2023-24 Volume 2 (P No: 45 I.No:8.25 )Rate 137.00+5%=143.85Sqm143.85143.8523.32FalseNoneNoneFalseNoneFalse3354.5820
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17203585970000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17203585970000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17203585970000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17203585970000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17203585970000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneContractor Civil LicenseCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneBankers CertificateCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneTurnover CertificateCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneWork done CertificateCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneGST CertificateCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateFalseTechnical Bid
Company Registration CertificateFalseTechnical Bid
Reserved Category CertificateFalseTechnical Bid
Small Scale Industries CertificateFalseTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone