1720505794000 | 1 | None | None | Buildings | CONSTRUCTION OF THREE CLASS ROOMS GOVT PRE-UNIVERSITY COLLEGE KALASA IN KALASA TALUK CHIKMAGALUR DIST | 5956474.35 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3494393 | 124758 | None | VOL-1,PG.NO-8,I.NO:1.14.1 | Earth work excavation for Foundation by mechanical means for all works &
depth upto 3 m, as per drawing and technical specifications, including setting
out, shoring, strutting, barricading, caution lights, including dressing of
excavated surfaces, disposing off or levelling the excavated earth or sorting
& stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5
m including cost of labour, tools, usage of machinery & other appurtenaces
required to complete the work
1.14.1 In all kinds of soils Depth upto 3 m ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Cum | 114.24 | 114.24 | 202.84 | False | None | None | False | None | False | 23172.4416 | 0 | 3494394 | 124758 | None | VOL-1,PG.NO:9,I.NO:1.15.2 | Earth work excavation for Foundation by mechanical means for all works &
depth upto 3 m, as per drawing and technical specifications, including setting
out, shoring, strutting, barricading, caution lights, including dressing of
excavated surfaces, disposing off or levelling the excavated earth or sorting
& stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5
m including cost of labour, tools, usage of machinery & other appurtenaces
required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth Depth exceeding 1.5 m, but not exceeding 3 m ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Cum | 476.0 | 476.0 | 50.71 | False | None | None | False | None | False | 24137.96 | 0 | 3494395 | 124758 | None | vol-2,pg.no:5,i.NO:4.1 | Providing and injecting chemical emulsion for Pre-constructional
Anti-Termite Treatment, creating continuous chemical barrier under
and around the column pits, walls, trenches, basement excavation, top
surface of the plinth filling, junction of wall and floor, along the external
perimeter of building, expansion joints, over the top surface of consolidated
earth on which apron is to be laid, surrounding of pipes and conduits with
Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2
including cost of
chemical, diluting in water to one percent concentration, labour, usage
charges of machinery, complete as per specifications. ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Sqm | 132.16 | 132.16 | 303.12 | False | None | None | False | None | False | 40060.3392 | 0 | 3494396 | 124758 | None | VOL-1,PG.NO:7.I.NO:1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of
foundations and other similar works etc. in layers not exceeding 20cm in depth,
consolidating each deposited layer by ramming and watering, lead up to 50 m
and lift upto 1.5 m. ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Cum | 297.92 | 297.92 | 202.84 | False | None | None | False | None | False | 60430.0928 | 0 | 3494397 | 124758 | None | VOL-1,PG.NO:7,I.NO:1.11 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations
and other similar works etc. in layers not exceeding 20cm in depth, consolidating
each deposited layer by ramming and watering, lead up to 50 m and lift upto
1.5 m ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Cum | 484.96 | 484.96 | 119.61 | False | None | None | False | None | False | 58006.0656 | 0 | 3494398 | 124758 | None | VOL-1,PG.NO:15,I.NO:2.1.3 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Cum | 6707.68 | 6707.68 | 64.75 | False | None | None | False | None | False | 434322.28 | 0 | 3494399 | 124758 | None | VOL-1,PG.NO:15,I.NO:2.2.3 | Providing and laying in position Cement Concrete for all Foundation works.
The granite/trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,
labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Cum | 7096.32 | 7096.32 | 42.45 | False | None | None | False | None | False | 301238.784 | 0 | 3494400 | 124758 | None | VL-1,PG.NO:111,I.NO:1a | Formwork, Centering & Scaffloding 8% For Isolated Footing ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Cum | 567.71 | 567.71 | 42.45 | False | None | None | False | None | False | 24099.2895 | 0 | 3494401 | 124758 | None | vol-1,pg.no:17,i.no:2.4.3 | Providing and laying in position Cement Concrete for all Sub structures of
building, Irrigation works, Sub structure works of bridges, Drain works &
other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt
crushed graded coarse aggregates and fine aggregates as per relevant IS
Codes machine mixed with super plasticisers, laid in layers, well compacted
using needle vibrators, providing weep holes wherever necessary, including
all lead & lifts, cost of all materials of quality, confirming to the requirements
of relevant IS codes, labour, Usage charges of machinery, curing and all other
appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Cum | 7096.32 | 7096.32 | 4.71 | False | None | None | False | None | False | 33423.6672 | 0 | 3494402 | 124758 | None | vol-1,pg.no:111,i.no:9 | Formwork, Centering & Scaffloding 70% For Columns up to plinth ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Cum | 4967.42 | 4967.42 | 4.71 | False | None | None | False | None | False | 23396.5482 | 0 | 3494403 | 124758 | None | vol-1,pg.no:16,i.no:2.5.2 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Cum | 7664.16 | 7664.16 | 10.69 | False | None | None | False | None | False | 81929.8704 | 0 | 3494404 | 124758 | None | vol-1,pg.no:111,i.no:9 | Formwork, Centering & Scaffloding 70% For Columns ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Cum | 5364.91 | 5364.91 | 10.69 | False | None | None | False | None | False | 57350.8879 | 0 | 3494405 | 124758 | None | vol-1,pg.no:16,i.no:2.4.3 | Providing and laying in position Cement Concrete for all Sub structures of
building, Irrigation works, Sub structure works of bridges, Drain works &
other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt
crushed graded coarse aggregates and fine aggregates as per relevant IS
Codes machine mixed with super plasticisers, laid in layers, well compacted
using needle vibrators, providing weep holes wherever necessary, including
all lead & lifts, cost of all materials of quality, confirming to the requirements
of relevant IS codes, labour, Usage charges of machinery, curing and all other
appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Cum | 7096.32 | 7096.32 | 20.65 | False | None | None | False | None | False | 146539.008 | 0 | 3494406 | 124758 | None | vol-1,pg.no:111,i.no:2 | Formwork, Centering & Scaffloding 50% For Plinth Beams & Curtain wall ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Cum | 3548.16 | 3548.16 | 20.65 | False | None | None | False | None | False | 73269.504 | 0 | 3494407 | 124758 | None | vol-1,pg.no:16,i.no:2.5.2 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Cum | 7664.16 | 7664.16 | 16.96 | False | None | None | False | None | False | 129984.1536 | 0 | 3494408 | 124758 | None | vol-1,pg.no:112,i.no:14 | Formwork, Centering & Scaffloding 60% For Beams & Lintel
---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Cum | 4598.5 | 4598.5 | 16.96 | False | None | None | False | None | False | 77990.56 | 0 | 3494409 | 124758 | None | vol-1,pg.no:16,i.no:2.5.2 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Cum | 7664.16 | 7664.16 | 40.74 | False | None | None | False | None | False | 312237.8784 | 0 | 3494410 | 124758 | None | vol-1,pg.no:112,i.no:15 | Formwork, Centering & Scaffloding 50% For Roof Slab & Staircase ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Cum | 3832.08 | 3832.08 | 40.74 | False | None | None | False | None | False | 156118.9392 | 0 | 3494411 | 124758 | None | vol-1,pg.no:16,i.no:2.5.2 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Cum | 7664.16 | 7664.16 | 1.61 | False | None | None | False | None | False | 12339.2976 | 0 | 3494412 | 124758 | None | vol-1,pg.no:112,i.no:14 | Formwork, Centering & Scaffloding 3% For Sill ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Cum | 229.92 | 229.92 | 1.61 | False | None | None | False | None | False | 370.1712 | 0 | 3494413 | 124758 | None | VOL-1,PG.NO:16,I.NO:2.5.2 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Cum | 7664.16 | 7664.16 | 0.65 | False | None | None | False | None | False | 4981.704 | 0 | 3494414 | 124758 | None | VOL-1,PG.NO:112,I.NO:19 | Formwork, Centering & Scaffloding 45% For Chejja ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Cum | 3448.87 | 3448.87 | 0.65 | False | None | None | False | None | False | 2241.7655 | 0 | 3494415 | 124758 | None | VOL-1,PG.NO:18,I.NO:2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and
technical specification.
a. Buildings ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | t | 100191.84 | 100191.84 | 13.93 | False | None | None | False | None | False | 1395672.3312 | 0 | 3494416 | 124758 | None | vol-2,pg.no:9,i.no:5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with
Cement mortar 1:6 (1 cement : 6 coarse sand) ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Cum | 7155.68 | 7155.68 | 4.8 | False | None | None | False | None | False | 34347.264 | 0 | 3494417 | 124758 | None | vol-2,PG.NO:17,I.NO:6.32 | Providing and constructing load bearing wall with Solid Concrete blocks
of size 400x200x200mm having block density more than 1800kg/m3
and minimum compressive strength of 4.00 N/mm2 conforming to IS
2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005
including cost of all materials, labour, scaffolding and curing, usage
charges of machinery etc complete as per specifications. ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Sqm | 1467.2 | 1467.2 | 278.63 | False | None | None | False | None | False | 408805.936 | 0 | 3494418 | 124758 | None | VOL-2,PG.NO:100,I.NO:12.13.1 | Providing Salwood frames of doors, windows, clerestory windows,
ventilators and other frames, wrought, framed or assembled including
making plaster groves (excluding cost of cement concrete and side clamps),
but including cost of materials, labour, usage charges complete as per
specifications ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Cum | 110672.8 | 110672.8 | 0.47 | False | None | None | False | None | False | 52016.216 | 0 | 3494419 | 124758 | None | VOL-2,PG.NO:105,I.NO:12.51 | Fixing of door frame in an existing opening including embedding frame in
floor and walls after cutting masonry for holdfasts for embedding holdfast
in cement concrete 1:3:6 of 20mm and down size granite metal painting
two coats of coal tar to sides of frame, making good the damages to walls
and floor as required and disposal of the debris with lead upto 50 m.
including cost of materials, labour charges, complete as per specifications. ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Nos | 1137.92 | 1137.92 | 6.0 | False | None | None | False | None | False | 6827.52 | 0 | 3494420 | 124758 | None | VOL-2,PG.NO:69,I.NO:10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of
bolt etc complete.Fastener with threaded dia 12 mm ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 67.2 | 67.2 | 36.0 | False | None | None | False | None | False | 2419.2 | 0 | 3494421 | 124758 | None | VOL-2,PG.NO:105,I.NO:12.57.3 | Providing and fixing flush door shutter made out of solid core block board
type, well seasoned , chemicaly treated hard wood battens and internal
frame with minimum 45 mm wide wooden frame alround door shutters
covered with cross bonded wooden sheets (core veneer) hot pressed and
fastened on both sides of the door useing liquid phenol formaldehyde
resin as per IS specifications 2202 (part-I) 1991. from manufacturer
complete as per spcification.-do- 30 mm thick both side commercial ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Sqm | 3365.6 | 3365.6 | 17.28 | False | None | None | False | None | False | 58157.568 | 0 | 3494422 | 124758 | None | VOL-2,PG.NO:110,I.NO:12.90 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi
chambered UPVC(Matching to RAL-9016) sections and with minimum
TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and
lead free, gaskets -grey colour having isolated drainage and reinforced with
Galvanized Iron profile through-out the window frame. The outer frame
having an overall size of 108mm width x 45mmheight with reinforcement
of 1mm thickness and Sash with overall size of 39mm x 75mm with GI
reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded
Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows
shall be provided with 6mm plain float glass, standard hardware& Multi
point locking system with touch lock. Wall thickness of frame & sash shall
be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The
cost is inclusive of all fixtures and separate charges for minor T&P's shall
not be made) ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Sqm | 7542.08 | 7542.08 | 21.6 | False | None | None | False | None | False | 162908.928 | 0 | 3494423 | 124758 | None | VOL-2,PG.NO:86,I.NO:11.34B | Providing and fixing M.S. grills of required pattern in frames of windows
etc. with M.S. flats, square or round bars etc. including priming coat with
approved steel primer all complete. Fixed to openings /wooden frames
with rawl plugs screws etc. ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Kg | 204.96 | 204.96 | 453.6 | False | None | None | False | None | False | 92969.856 | 0 | 3494424 | 124758 | None | VOL-2,PG.NO:41,I.NO:8.1.2 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement:
6 fine sand) including rounding off corners wherever required smooth
rendering, providing and removing scaffolding, including cost of materials,
labour, curing complete as per specifications and as per directions of
Engineer-in-charge. ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Sqm | 269.92 | 269.92 | 339.52 | False | None | None | False | None | False | 91643.2384 | 0 | 3494425 | 124758 | None | VOL-2,PG.NO:50,I.NO:8.51 | Providing and applying white cement based putty of average thickness
1 mm, of approved brand and manufacturer, over the plastered
wall surface to prepare the surface even and smooth complete as per
specifications and as per directions of Engineer in charge. ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Sqm | 112.0 | 112.0 | 729.63 | False | None | None | False | None | False | 81718.56 | 0 | 3494426 | 124758 | None | VOL-2,PG.NO:42,I.NO:8.8 | Providing 18 mm cement plaster in two coats under layer 12 mm thick
cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished
with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1
cement : 6 fine sand) to brick masonry including rounding off corners
wherever required smooth rendering, providing and removing scaffolding,
including cost of materials, labour, curing complete as per specifications
and as per directions of Engineer-in-charge. ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Sqm | 415.52 | 415.52 | 419.88 | False | None | None | False | None | False | 174468.5376 | 0 | 3494427 | 124758 | None | VOL-2,PG.NO:59,I.NO:9.2 | Providing and laying 52 mm thick cement concrete flooring with concrete
hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and
top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement
hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume,
hardening compound mixed @ 2 L per 50 kg of cement or as per direction
of Engineer incharge. ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Sqm | 896.0 | 896.0 | 49.14 | False | None | None | False | None | False | 44029.44 | 0 | 3494428 | 124758 | None | VOL-2,PG.NO:61,I.NO:9.17.2 | Providing and laying Vitrified tiles with thickness 9-10 mm in different
sizes with water absorption less than 0.08 % and conforming to I.S. 15622,
of approved make, in all colours & shade, over 12 mm thick bed of cement
mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry
@ 3.3 kg/ m2 including grouting the joint with white cement & matching
pigments etc. complete.Size of Tile 600x600 mm ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Sqm | 1316.0 | 1316.0 | 227.4 | False | None | None | False | None | False | 299258.4 | 0 | 3494429 | 124758 | None | VOL-2,PG.NO:63,I.NO:9.24 | Providing and laying Polished Granite stone flooring in required design
and patterns, in linear as well as curvilinear portions of the building all
complete as per the architectural drawings with 18 mm thick stone slab
over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4
coarse sand) laid and jointed with cement slurry and pointing with white
cement slurry admixed with pigment of matching shade including rubbing,
curing and polishing etc. all complete as specified and as directed by the
Engineer-in-Charge.
** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Sqm | 3194.24 | 3194.24 | 85.76 | False | None | None | False | None | False | 273938.0224 | 0 | 3494430 | 124758 | None | VOL-2,PG.NO:84,I.NO:11.25.2 | Providing and fixing Steel work welded in built up sections/ framed
work, including cutting, hoisting, fixing in position and applying a priming
coat of approved steel primer using structural steel etc. as required. In
gratings, frames, guard bar, ladder, railings, brackets, gates and similar
works including cost of materials, labour, usage charges of machinery
complete as per specifications and as per directions of the Engineer-inCharge ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Kg | 152.32 | 152.32 | 85.59 | False | None | None | False | None | False | 13037.0688 | 0 | 3494431 | 124758 | None | VOL-2,PG.NO:46,I.NO:8.33.1 | Finishing with Deluxe Multi surface paint system for interiors and exteriors
using Primer as per manufacturers specifications: Two coats applied on
walls @ 1.25 L/10 m² over and including one coat of Special primer applied
@ 0.75 L/10 m² with paint of approved quality to give an even shade, after
thoroughly brooming the surface to remove all dirt, dust, mortar drops
and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree
angle with 10 years life) ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Sqm | 176.96 | 176.96 | 729.6 | False | None | None | False | None | False | 129110.016 | 0 | 3494432 | 124758 | None | VOL-2,PG.NO:46,I.NO:8.30 | Finishing walls with Acrylic Smooth exterior paint of required shade :New
work (Two coat applied @ 1.67L/10 m² over and including priming coat of
exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality
to give an even shade, after thoroughly brooming the surface to remove all
dirt, dust, mortar drops and foreign matter including preparing the surface
even and sand paper smooth, cost of materials, labour complete as per
specifications and as per directions of Engineer-in-charge. ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Sqm | 194.88 | 194.88 | 419.88 | False | None | None | False | None | False | 81826.2144 | 0 | 3494433 | 124758 | None | VOL-2,PG.NO:47,I.NO:8.33.3 | Painting Steel work with Deluxe Multi Surface Paint to give an even
shade. Two coat applied @ 0.90L/10 m² over an under coat of primer
applied @ 0.80 L/10 m² of approved brand and manufacture including
preparing the surface after thorougly cleaning oil, grease, dirt and foreign
matter, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge. ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Sqm | 155.68 | 155.68 | 21.6 | False | None | None | False | None | False | 3362.688 | 0 | 3494434 | 124758 | None | VOL-2,PG.NO:149,I.NO:15.1 | Polyurethane based Single Component for New Surface
Providing and laying water proofing treatment to the Roof with PU based
single component elastomeric pure polyurethane based coating on New
terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing
membrane that is highly elastic with elongation greater than
400% and tensile strength greater than 2MPa as per ASTM D412. The
waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve
final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy
primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing
membrane. The finished cost to include surface preparation,
making coving at Junction, Bore Packing, treatment of construction joints
completely as per specification. ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Sqm | 915.04 | 915.04 | 303.12 | False | None | None | False | None | False | 277366.9248 | 0 | 3494435 | 124758 | None | VOL-2,PG.NO:125,I.NO:13.49 | Providing and fixing on wall face unplasticised Rigid PVC rain water
pipes of 150mm dia conforming to IS : 13592 Type A, including jointing
with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal
expansion, (i) Single socketed pipes. ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | m | 636.16 | 636.16 | 27.6 | False | None | None | False | None | False | 17558.016 | 0 | 3494436 | 124758 | None | VOL-3,PG.NO:26,I.NO:4.17 | Wet Mix Macadam (Plant Mix Method)
Providing, laying, spreading and compacting graded stone
aggregate to wet mix macadam specification including premixing
the Material with water at OMC in mechanical mix plant carriage
of mixed Material by tipper to site, laying in uniform layers with
paver/grader in sub-base / base course on well prepared surface
and compacting with vibratory roller to achieve the desired density. ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Cum | 2866.08 | 2866.08 | 15.0 | False | None | None | False | None | False | 42991.2 | 0 | 3494437 | 124758 | None | VOL-2,PG.NO:63,I.NO:9.25 | Providing and laying 60mm thick factory made cement concrete paver
block of approved shape and colour of M -30 grade made of C&D waste
by block making machine with vibratory compaction laid in required
pattern and including over 50mm thick compacted bed of coarse sand,
filling the joints with fine sand etc. all complete as per the direction of
Engineer-in-charge. ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Sqm | 896.0 | 896.0 | 150.0 | False | None | None | False | None | False | 134400.0 | 0 |
| 1720505794000 | 0 | None | None | Buildings | ELLECTRIFICATION WORK FOR CONSTRUCTION OF THREE CLASS ROOMS GOVT PRE-UNIVERSITY COLLEGE KALASA IN KALASA TALUK CHIKMAGALUR DIST | 356711.94 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3494438 | 124759 | None | ELLE SR 1.2, 1.2.1 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thick ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | m | 73.92 | 73.92 | 90.0 | False | None | None | False | None | False | 6652.8 | 0 | 3494439 | 124759 | None | ELLE SR 1.2, 1.2.2 | Supplying heavy gauge PVC conduit pipe mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thick ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | m | 87.36 | 87.36 | 60.0 | False | None | None | False | None | False | 5241.6 | 0 | 3494440 | 124759 | None | ELLE SR 1.5 1.5.1 | Supplying and fixing PVC/metal conduit Deep junction box 19/20 mm deep Junction box ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 54.88 | 54.88 | 60.0 | False | None | None | False | None | False | 3292.8 | 0 | 3494441 | 124759 | None | ELLE SR 1.5 1.5.2 | Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction box ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 62.72 | 62.72 | 30.0 | False | None | None | False | None | False | 1881.6 | 0 | 3494442 | 124759 | None | ELLE SR 1.3 1.3.1 | Supplying heavy gauge PVC Conduit Pipe .... dia mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20 mm dia 2 mm thick ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | m | 76.16 | 76.16 | 90.0 | False | None | None | False | None | False | 6854.4 | 0 | 3494443 | 124759 | None | ELLE SR 1.3 1.3.2 | Supplying heavy gauge PVC Conduit Pipe .... dia mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25 mm dia 2 mm thick ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | m | 88.48 | 88.48 | 60.0 | False | None | None | False | None | False | 5308.8 | 0 | 3494444 | 124759 | None | ELLE SR 1.13 | Supplying And Fixing Metal Fan Box with Round Hook. ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | No | 131.04 | 131.04 | 10.0 | False | None | None | False | None | False | 1310.4 | 0 | 3494445 | 124759 | None | ELLE SR 2.2 2.2.1 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3m from tapping point to out let via switch box ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Point | 301.28 | 301.28 | 15.0 | False | None | None | False | None | False | 4519.2 | 0 | 3494446 | 124759 | None | ELLE SR 2.2 2.2.2 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3m upto 6m from tapping point to out let
via switch box ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Point | 424.48 | 424.48 | 15.0 | False | None | None | False | None | False | 6367.2 | 0 | 3494447 | 124759 | None | ELLE SR 3.4 3.4.1 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3 Way ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 154.56 | 154.56 | 15.0 | False | None | None | False | None | False | 2318.4 | 0 | 3494448 | 124759 | None | ELLE SR 3.4 3.4.3 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5 Way ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 198.24 | 198.24 | 10.0 | False | None | None | False | None | False | 1982.4 | 0 | 3494449 | 124759 | None | ELLE SR 3.4 3.4.4 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6 Way ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 246.4 | 246.4 | 4.0 | False | None | None | False | None | False | 985.6 | 0 | 3494450 | 124759 | None | ELLE SR 3.4 3.4.5 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 292.32 | 292.32 | 4.0 | False | None | None | False | None | False | 1169.28 | 0 | 3494451 | 124759 | None | ELLE SR 3.5 3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 180.32 | 180.32 | 10.0 | False | None | None | False | None | False | 1803.2 | 0 | 3494452 | 124759 | None | ELLE SR 3.5 3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 196.0 | 196.0 | 4.0 | False | None | None | False | None | False | 784.0 | 0 | 3494453 | 124759 | None | ELLE SR 3.5 3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 262.08 | 262.08 | 4.0 | False | None | None | False | None | False | 1048.32 | 0 | 3494454 | 124759 | None | ELLE SR 3.5 3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 318.08 | 318.08 | 2.0 | False | None | None | False | None | False | 636.16 | 0 | 3494455 | 124759 | None | ELLE SR 3.6 3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 114.24 | 114.24 | 12.0 | False | None | None | False | None | False | 1370.88 | 0 | 3494456 | 124759 | None | ELLE SR 3.6 3.6.2 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Two Way Switch ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 185.92 | 185.92 | 6.0 | False | None | None | False | None | False | 1115.52 | 0 | 3494457 | 124759 | None | ELLE SR 3.6 3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Three Way socket ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 191.52 | 191.52 | 4.0 | False | None | None | False | None | False | 766.08 | 0 | 3494458 | 124759 | None | ELLE SR 3.6 3.6.4 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 399.84 | 399.84 | 6.0 | False | None | None | False | None | False | 2399.04 | 0 | 3494459 | 124759 | None | ELLE SR 3.6 3.6.8 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Bell Push ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 198.24 | 198.24 | 6.0 | False | None | None | False | None | False | 1189.44 | 0 | 3494460 | 124759 | None | ELLE SR 3.6 3.6.9 | 32A DP Switch ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 365.12 | 365.12 | 3.0 | False | None | None | False | None | False | 1095.36 | 0 | 3494461 | 124759 | None | ELLE SR 3.6 3.6.10 | 6/16A Universal Socket ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 264.32 | 264.32 | 2.0 | False | None | None | False | None | False | 528.64 | 0 | 3494462 | 124759 | None | ELLE SR 3.1 3.10.2 | Extra for supplying 4 mm thick white plastic plate and covering for junction boxes of size ...... mm conduit using
necessary machine screws. 80/90 mm ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | No | 16.8 | 16.8 | 60.0 | False | None | None | False | None | False | 1008.0 | 0 | 3494463 | 124759 | None | ELLE SR 3.1 3.10.3 | Extra for supplying 4 mm thick white plastic plate and covering for junction boxes of size ...... mm conduit using
necessary machine screws. 110 mm ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | No | 23.52 | 23.52 | 30.0 | False | None | None | False | None | False | 705.6 | 0 | 3494464 | 124759 | None | ELLE SR 2.3 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2 ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | m | 29.12 | 29.12 | 90.0 | False | None | None | False | None | False | 2620.8 | 0 | 3494465 | 124759 | None | ELLE SR 2.3 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2 ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | m | 47.04 | 47.04 | 90.0 | False | None | None | False | None | False | 4233.6 | 0 | 3494466 | 124759 | None | ELLE SR 2.3 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 mm2 ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | m | 70.56 | 70.56 | 60.0 | False | None | None | False | None | False | 4233.6 | 0 | 3494467 | 124759 | None | ELLE SR 2.3 2.3.5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 mm2 ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | m | 103.04 | 103.04 | 30.0 | False | None | None | False | None | False | 3091.2 | 0 | 3494468 | 124759 | None | ELLE SR 5.7 5.7.4 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 100 A ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 773.92 | 773.92 | 8.0 | False | None | None | False | None | False | 6191.36 | 0 | 3494469 | 124759 | None | ELLE SR 5.18 5.18.1 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 464.8 | 464.8 | 4.0 | False | None | None | False | None | False | 1859.2 | 0 | 3494470 | 124759 | None | ELLE SR 5.18 5.18.4 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A DP ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 827.68 | 827.68 | 2.0 | False | None | None | False | None | False | 1655.36 | 0 | 3494471 | 124759 | None | ELLE SR 5.18 5.18.6 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 Amps DP ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 1234.24 | 1234.24 | 2.0 | False | None | None | False | None | False | 2468.48 | 0 | 3494472 | 124759 | None | ELLE SR 5.18 5.18. 7 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32Amps TPN ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 1923.04 | 1923.04 | 2.0 | False | None | None | False | None | False | 3846.08 | 0 | 3494473 | 124759 | None | ELLE SR 5.19 5.19.7 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. II - Double Door 6 Way SP & N ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 2005.92 | 2005.92 | 4.0 | False | None | None | False | None | False | 8023.68 | 0 | 3494474 | 124759 | None | ELLE SR 5.19 5.19.13 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. III - Double Door 8 Way TP & N ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 6821.92 | 6821.92 | 4.0 | False | None | None | False | None | False | 27287.68 | 0 | 3494475 | 124759 | None | ELLE SR 5.15, 5.15.9 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=1012% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR Pole 100 A 25 kA ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 9505.44 | 9505.44 | 2.0 | False | None | None | False | None | False | 19010.88 | 0 | 3494476 | 124759 | None | ELLE SR 5.20 5.20.1 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V upto 300mA sensitivity on existing wood/panel board. 16-25 A 2 pole ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 4790.24 | 4790.24 | 2.0 | False | None | None | False | None | False | 9580.48 | 0 | 3494477 | 124759 | None | ELLE SR 5.20 5.20.10 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V upto 300mA sensitivity on existing wood/panel board. 63 A 4 pole ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 6210.4 | 6210.4 | 1.0 | False | None | None | False | None | False | 6210.4 | 0 | 3494478 | 124759 | None | ELLE SR 5.12 5.12.1 | Supplying of on load change over switches 4 poles, AC 23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM
Enclosure Sheet Metal Execution) 63 A ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 7706.72 | 7706.72 | 2.0 | False | None | None | False | None | False | 15413.44 | 0 | 3494479 | 124759 | None | ELLE SR 6.3 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular model ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 3342.08 | 3342.08 | 12.0 | False | None | None | False | None | False | 40104.96 | 0 | 3494480 | 124759 | None | ELLE SR 13.11 | Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clA and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 352.8 | 352.8 | 12.0 | False | None | None | False | None | False | 4233.6 | 0 | 3494481 | 124759 | None | ELLE SR 13.12 | Extra length of GI pipe of class B 19mm dia for down rod. ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | m | 220.64 | 220.64 | 12.0 | False | None | None | False | None | False | 2647.68 | 0 | 3494482 | 124759 | None | ELLE SR 11.3 11.3.1 | Supplying of ....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 712% lumen maintenance with CRI 80. Power Input: 220 240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' 9/10 W ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 617.12 | 617.12 | 10.0 | False | None | None | False | None | False | 6171.2 | 0 | 3494483 | 124759 | None | ELLE SR 11.3 11.3.2 | Supplying of .....feet PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 712% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 772.8 | 772.8 | 20.0 | False | None | None | False | None | False | 15456.0 | 0 | 3494484 | 124759 | None | ELLE SR 3.14 3.14.6 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A Lamp Holder ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | No | 79.52 | 79.52 | 6.0 | False | None | None | False | None | False | 477.12 | 0 | 3494485 | 124759 | None | ELLE SR 11.11, 11.11.7 | Supplying & fixing of retrofit type LED bulb . W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 712%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 212%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18W, 6500K ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 477.12 | 477.12 | 6.0 | False | None | None | False | None | False | 2862.72 | 0 | 3494486 | 124759 | None | ELLE SR 11.4,11.4.3 | Supplying of recess mounting non integrated type LED down light. W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clA, LED of Power/COB with CCT 6500 degree K, CRI 712%. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 212%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 15-18W ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 1871.52 | 1871.52 | 6.0 | False | None | None | False | None | False | 11229.12 | 0 | 3494487 | 124759 | None | ELLE SR 13.7, 13.7.1 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. On wall/ ceiling / Rafter / Girders ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 136.64 | 136.64 | 49.0 | False | None | None | False | None | False | 6695.36 | 0 | 3494488 | 124759 | None | ELLE SR 11.8, 11.8.4 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 712%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have inhouse facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect LED Streetlight 90 W ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | No. | 9923.2 | 9923.2 | 1.0 | False | None | None | False | None | False | 9923.2 | 0 | 3494489 | 124759 | None | ELLE SR 13.2, 13.2.1 | Supplying and Fixing.mm dia class A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clA, bolts, nuts and wiring using suitable capacity wires. Using 25mm dia G.I.Pipe ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 1347.36 | 1347.36 | 1.0 | False | None | None | False | None | False | 1347.36 | 0 | 3494490 | 124759 | None | ELLE SR 5.21 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 10365.6 | 10365.6 | 1.0 | False | None | None | False | None | False | 10365.6 | 0 | 3494491 | 124759 | None | ELLE SR 5.29 | Supplying, fixing and wiring 3 Phase Digital Ammeter /Voltmeter ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 1596.0 | 1596.0 | 1.0 | False | None | None | False | None | False | 1596.0 | 0 | 3494492 | 124759 | None | ELLE SR 5.34 | Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound. ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 629.44 | 629.44 | 1.0 | False | None | None | False | None | False | 629.44 | 0 | 3494493 | 124759 | None | ELLE SR 5.35 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 A three phase 4 wire whole current class-1 Accuracy
Energy Meter. ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 6389.6 | 6389.6 | 1.0 | False | None | None | False | None | False | 6389.6 | 0 | 3494494 | 124759 | None | ELLE SR 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Each | 576.8 | 576.8 | 2.0 | False | None | None | False | None | False | 1153.6 | 0 | 3494495 | 124759 | None | ELLE SR 5.40, 5.40.1 | Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 100 A 4 x 30 x 6 mm Aluminium Strips ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | m | 2760.8 | 2760.8 | 1.8 | False | None | None | False | None | False | 4969.44 | 0 | 3494496 | 124759 | None | ELLE SR 5.42 5.42.2 | Fabricating supplying and mounting MS box made out ...SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 16 SWG ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | cm | 0.48 | 0.48 | 12000.0 | False | None | None | False | None | False | 5760.0 | 0 | 3494497 | 124759 | None | ELLE SR 32 32.11 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm) ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Km | 200449.76 | 200449.76 | 0.15 | False | None | None | False | None | False | 30067.464 | 0 | 3494498 | 124759 | None | VOL-1, PG.NO-10,I.NO:1.17 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical
means as per drawing and technical specifications, including setting out,
construction of shoring, strutting, barricading, caution lights, bracing, using
sight rails & bonding rods at every 100 mm wherever necessary as directed,
removal of stumps and other deleterious matter, dressing of sides and levelling
the bottom of trench to the extent required , utilising the available excavated
earth locally for the work etc., and all other appurtenances complete in the
following strata.
1.17.1 All kinds of soils. Depth upto 1.50 m ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Cum | 293.44 | 293.44 | 30.0 | False | None | None | False | None | False | 8803.2 | 0 | 3494499 | 124759 | None | ELLE SR 5.41 5.41.1 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mm ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | m | 341.6 | 341.6 | 6.0 | False | None | None | False | None | False | 2049.6 | 0 | 3494500 | 124759 | None | ELLE SR 5.41 5.41.2 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 50 x 50 x 6 mm ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | m | 442.4 | 442.4 | 4.0 | False | None | None | False | None | False | 1769.6 | 0 | 3494501 | 124759 | None | ELLE SR 51.04 | Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | No | 2432.64 | 2432.64 | 1.0 | False | None | None | False | None | False | 2432.64 | 0 | 3494502 | 124759 | None | ELLE SR 51.05 | Bentonite clay slurry for earthing in 50 Kg Bag ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Bag | 412.16 | 412.16 | 1.0 | False | None | None | False | None | False | 412.16 | 0 | 3494503 | 124759 | None | ELLE SR 51.02 | Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | No | 757.12 | 757.12 | 1.0 | False | None | None | False | None | False | 757.12 | 0 | 3494504 | 124759 | None | ELLE SR 51.03 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag ---- Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipments with all lead and lifts, loading and unloading charges etc.. Complete as directed as per specification and direction of Engineer in-charge of the work. | Bag | 347.2 | 347.2 | 1.0 | False | None | None | False | None | False | 347.2 | 0 |
|
|
---|