tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1720765012000 | 0 | None | None | Buildings | civil work | 6174477.33 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3513133 | 125945 | None | code01 | Earth work in surface excavation for stripping, seating of bund, Road way, by
manual means for lowering and leveling the ground for all works other than
foundation and depth in all kinds of soil not exceeding 300mm as per drawing and
technical specifications, including setting out, shoring, strutting, barricading,
caution lights, removal of stumps and other deleterious matter including
dressing of excavated surfaces, disposing off or levelling the excavated earth or
sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto
1.5 m including cost of labour, tools, usage and other appurtenances required to
complete the work. | Cum | 95.55 | 95.55 | 66.96 | False | None | None | False | None | False | 6398.028 | 0 | 3513134 | 125945 | None | code02 | Earth work excavation by manual means for drains,canals, waste weir draft,
approach channels, key trench, foundation of Bridges and such similar works,
as per drawing and technical specifications, including setting out, shoring,
strutting, barricading, caution lights, excavated surface leveled and sides neatly
dressed disposing off or leveling the excavated stuff or sorting and stacking the
selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost
of labour, tools, usage and other appurtenances required to complete the work.
1.5.1 In ordinaryorsoft rock without blasting upto 1.5 m depth | Cum | 313.95 | 313.95 | 191.76 | False | None | None | False | None | False | 60203.052 | 0 | 3513135 | 125945 | None | code03 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The graniteortraporbasalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead and lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications.Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6527.85 | 6527.85 | 21.77 | False | None | None | False | None | False | 142111.2945 | 0 | 3513136 | 125945 | None | code04 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works and super structure works
of bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead and lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications.
2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7170.35 | 7170.35 | 18.16 | False | None | None | False | None | False | 130213.556 | 0 | 3513137 | 125945 | None | code05 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works and super structure works
of bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead and lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications.
2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11834.6 | 11834.6 | 5.68 | False | None | None | False | None | False | 67220.528 | 0 | 3513138 | 125945 | None | code06 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works and super structure works
of bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead and lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications.
2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11834.55 | 11834.55 | 12.44 | False | None | None | False | None | False | 147221.802 | 0 | 3513139 | 125945 | None | code07 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works and super structure works
of bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead and lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications.
2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10442.25 | 10442.25 | 7.82 | False | None | None | False | None | False | 81658.395 | 0 | 3513140 | 125945 | None | code08 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works and super structure works
of bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead and lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications.
2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11138.4 | 11138.4 | 19.1 | False | None | None | False | None | False | 212743.44 | 0 | 3513141 | 125945 | None | code09 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works and super structure works
of bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead and lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications.
2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10442.25 | 10442.25 | 56.57 | False | None | None | False | None | False | 590718.0825 | 0 | 3513142 | 125945 | None | code10 | Providing Random rubble masonry with hard stone in foundation and
plinth including levelling up with cement concrete 1:6:12 (1 cement : 6
coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth
level with :
5.1.1 Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5891.55 | 5891.55 | 79.71 | False | None | None | False | None | False | 469615.4505 | 0 | 3513143 | 125945 | None | code11 | Providing Coursed rubble masonry (second sort) with hard stone in
foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6515.25 | 6515.25 | 27.6 | False | None | None | False | None | False | 179820.9 | 0 | 3513144 | 125945 | None | code12 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of
foundations and other similar works etc. in layers not exceeding 20cm in depth,
consolidating each deposited layer by ramming and watering, lead up to 50 m
and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 227.46 | False | None | None | False | None | False | 63529.578 | 0 | 3513145 | 125945 | None | code13 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The graniteortraporbasalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead and lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications.Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6527.85 | 6527.85 | 30.33 | False | None | None | False | None | False | 197989.6905 | 0 | 3513146 | 125945 | None | code14 | Providing Honne wood frames of doors, windows, clerestory windows,
ventilators and other frames, wrought, framed or assembled including
making plaster groves (excluding cost of cement concrete and side clamps),
but including cost of materials, labour, usage charges complete as per
specifications | Cum | 144977.7 | 144977.7 | 0.694 | False | None | None | False | None | False | 100614.5238 | 0 | 3513147 | 125945 | None | code15 | Providing Brick work with common burnt clay modular bricks of class
designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement
: 4 coarse sand) including cost of all materials, labour, scaffolding and
usage charges of machinery and other incidental charges complete as per
the direction of engineer incharge of work. | Cum | 9317.7 | 9317.7 | 79.31 | False | None | None | False | None | False | 738986.787 | 0 | 3513148 | 125945 | None | code16 | Supplying, fitting and placing TMT FE 550 or 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, lapingorwelding joints, tying with binding wire or soft
annealed steel wire and other ancilary operations complete as per drawing and
technical specification.
a. Buildings | Tonne | 93929.85 | 93929.85 | 10.45 | False | None | None | False | None | False | 981566.9325 | 0 | 3513149 | 125945 | None | code17 | Providing 15 mm cement plaster on the rough side of single or half brick
wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners
wherever required smooth rendering, providing and removing scaffolding,
including cost of materials, labour, curing complete as per specifications
and as per directions of Engineer-in-charge. | Sqm | 309.75 | 309.75 | 670.7 | False | None | None | False | None | False | 207749.325 | 0 | 3513150 | 125945 | None | code18 | Providing 18 mm cement plaster in two coats under layer 12 mm thick
cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished
with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1
cement : 6 fine sand) to brick masonry including rounding off corners
wherever required smooth rendering, providing and removing scaffolding,
including cost of materials, labour, curing complete as per specifications
and as per directions of Engineer-in-charge. | Sqm | 389.55 | 389.55 | 475.48 | False | None | None | False | None | False | 185223.234 | 0 | 3513151 | 125945 | None | code19 | Providing and fixing M.S. grills of required pattern in frames of windows
etc. with M.S. flats, square or round bars etc. including priming coat with
approved steel primer all complete. Fixed to openings orwooden frames
with rawl plugs screws etc. | Kgs | 192.15 | 192.15 | 571.5 | False | None | None | False | None | False | 109813.725 | 0 | 3513152 | 125945 | None | code20 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi
chambered UPVC(Matching to RAL-9016) sections and with minimum
TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and
lead free, gaskets -grey color having isolated drainage and reinforced with
Galvanized Iron profile through-out the window frame. The outer frame
having an overall size of 44mm width x 40mmheight with reinforcement
of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC | Sqm | 5274.15 | 5274.15 | 38.1 | False | None | None | False | None | False | 200945.115 | 0 | 3513153 | 125945 | None | code21 | Providing and fixing in position fully panelled Honne wood shutters for
doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm
wide top rail and stiles 100mm wide as per drawing and panels of 25mm
thick including cost of materials, labour, usage charges complete as per
specifications. ( excluding cost of fixtures ) | Sqm | 7816.2 | 7816.2 | 17.22 | False | None | None | False | None | False | 134594.964 | 0 | 3513154 | 125945 | None | code22 | Distempering with oil bound washable distemper of approved brand
and manufacture to give an even shade :New work (two coats) over and in cluding water thinnable priming coat with cement primer after thoroughly
brooming the surface to remove all dirt, dust, mortar drops and foreign
matter including preparing the surface even and sand paper smooth, cost
of materials, labour complete as per specifications and as per directions
of Engineer-in-charge. | Sqm | 143.85 | 143.85 | 670.7 | False | None | None | False | None | False | 96480.195 | 0 | 3513155 | 125945 | None | code23 | Finishing walls with textured exterior paint of required shade :New work
(Two coats applied at 3.28 Lor10 sqm) over and including priming coat of
exterior primer applied at 2.20kgor10 sqm to give an even shade after
thoroughly brooming the surface to remove all dirt, dust, mortar drops
and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 297.15 | 297.15 | 475.48 | False | None | None | False | None | False | 141288.882 | 0 | 3513156 | 125945 | None | code24 | Providing and laying Polished Glazed Vitrified tiles with thickness 10
mm in floor with different sizes with water absorption less than 0.08percent
and conforming to IS:15622, of approved brand and manufacturer, in all
colours and shade, laid with cement based high polymer modified quick
set tile adhesive (water based) conforming to IS : 15477, in average 6 mm
thickness, including grouting of joints (Payment for grouting of joints to
be made separately). | Sqm | 1392.3 | 1392.3 | 315.41 | False | None | None | False | None | False | 439145.343 | 0 | 3513157 | 125945 | None | code25 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm
thick on 10mm thick cement plaster 1:3 and jointed with white cement
slurry over existing rough plaster surface using glazed tiles of approved
make and size including cost of materials, labour, complete as per
specifications. | Sqm | 1521.45 | 1521.45 | 15.7 | False | None | None | False | None | False | 23886.765 | 0 | 3513158 | 125945 | None | code26 | Painting wood work with Deluxe Multi Surface Paint of required shade.
Two coat applied at 0.90Lor10 sqm over an under coat of primer applied
at0.75 Lor10 sqm of approved brand and manufacture to give an even shade
including preparing the surface after thorougly cleaning oil, grease, dirt
and foreign matter, sand papering and knotting , cost of materials, labour
complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 144.9 | 144.9 | 38.75 | False | None | None | False | None | False | 5614.875 | 0 | 3513159 | 125945 | None | code27 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow
tubes, channels, plates etc., including welding, grinding, buffing, polishing
and making curvature (wherever required) and fitting the same with
necessary stainless steel nuts and bolts complete, iorc fixing the railing
with necessary accessories and stainless steel dash fasteners, stainless
steel bolts etc., of required size, on the top of the floor or the side of waist
slab with suitable arrangement as per approval of Engineer-in- charge,
(for payment purpose only weight of stainless steel members shall be
considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
including cost of materials, labour, usage charges of machinery complete
as per specifications and as per directions of the Engineer-in-Charge. | Kgs | 595.35 | 595.35 | 677.72 | False | None | None | False | None | False | 403480.602 | 0 | 3513160 | 125945 | None | code28 | Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013
with latest amendments ended with integral sockets with ISI mark and
conveying to worksite, rolling and lowering into trenches, laying true to
line and level and perfect linking at joints, testing and commissioning,
including loading and unloading at both destinations and cuts of pipes
wherever necessary including jointing of UPVC pipes (with cost of
elastomeric sealing rings) and specials (excluding cost of specials) with
jointing of approved type, with all labour, lead and lifts, including encasing
the pipes alround to a depth of not less than 15 cms. with soft gravel
or selected earth available from the excavation etc. complete and giving
necessary hydraulic test to the required pressure as per ISS (contractor
will make his own arrangements for procuring water for testing) etc.
complete for:
.110mm dia 6kgorsqcm | Mtr | 271.0 | 271.0 | 100.0 | False | None | None | False | None | False | 27100.0 | 0 | 3513161 | 125945 | None | code29 | Lettering with black Japan paint of approved brand and manufacture to give
an even shade including preparing the surface after thoroughly cleaning the
surface to remove all dirt, dust and foreign matter, cost of materials, labour
complete as per specifications and as per directions of Engineer-in-charge. | cm | 3.15 | 3.15 | 4500.0 | False | None | None | False | None | False | 14175.0 | 0 | 3513162 | 125945 | None | code30 | Providing and fixing precoated galvanised iron profile sheets (size, shape
and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+
0.05 percent) total coated thickness with zinc coating 120 gorm2
as per IS: 277,
in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet
and polyester top coat 15-18 microns. Sheet should have protective guard
film of 25 microns minimum to avoid scratches during transportation and
should be supplied in single length upto 12 m or as desired by Engineer in-charge. The sheet shall be fixed using self drillingorself tapping screws of
size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontalor
vertical or curved surfaces, excluding the cost of purlins, rafters and trusses
and including cutting to size and shape wherever required. | Sqm | 596.4 | 596.4 | 24.09 | False | None | None | False | None | False | 14367.276 | 0 |
| 1720765012000 | 0 | None | None | Buildings | ELECTRICAL | 145587.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3513163 | 125946 | None | code01 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm .... etc. as required.25mm | Mtr | 28.0 | 28.0 | 250.0 | False | None | None | False | None | False | 7000.0 | 0 | 3513164 | 125946 | None | code02 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete.4"x4"x3" ( 101x101x76mm) | Each | 69.0 | 69.0 | 30.0 | False | None | None | False | None | False | 2070.0 | 0 | 3513165 | 125946 | None | code03 | Supplying and wiring adopting loop system in existing PVCConduit orcasing capping using 2x1.5mm2 (Phase and Neutral)and 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulatedcopper wire (confirming to IS-694: and latest amendments) witha 6A flush type SP control switch shall be fixed on the existing plastic sheetor gang box, the other end of the wires shall be terminated with sufficient loose length in a woodorPVC round block. complete for each outlet.Using class A Materials b) Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch | Point | 386.0 | 386.0 | 15.0 | False | None | None | False | None | False | 5790.0 | 0 | 3513166 | 125946 | None | code04 | Supplying and wiring adopting loop system in existing PVCConduit orcasing capping using 2x1.5mm2 (Phase and Neutral)and 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulatedcopper wire (confirming to IS-694: and latest amendments) witha 6A flush type SP control switch shall be fixed on the existing plastic sheetor gang box, the other end of the wires shall be terminated with sufficient loose length in a woodorPVC round block. complete for each outlet.Using class A Materials b) Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch c) Long point above 6Mtr up to 10Mtr from tapping point to out let via switch | Point | 567.0 | 567.0 | 15.0 | False | None | None | False | None | False | 8505.0 | 0 | 3513167 | 125946 | None | code05 | Wiring for lightingorpower circuit using one of FRLS PVC
insulated 1100V grade, multi strand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 1.5 sqmm | Mtr | 26.0 | 26.0 | 350.0 | False | None | None | False | None | False | 9100.0 | 0 | 3513168 | 125946 | None | code06 | Wiring for lightingorpower circuit using one of FRLS PVC
insulated 1100V grade, multi strand copper wire with low2.5 sqm | Mtr | 40.0 | 40.0 | 60.0 | False | None | None | False | None | False | 2400.0 | 0 | 3513169 | 125946 | None | code07 | Wiring for lightingorpower circuit using one of FRLS PVC
insulated 1100V grade, multi strand copper wire with low4sqm | Mtr | 59.0 | 59.0 | 250.0 | False | None | None | False | None | False | 14750.0 | 0 | 3513170 | 125946 | None | code08 | Supplying and flush mounting powder coated or galvanized
metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 1-3Way | Each | 123.0 | 123.0 | 9.0 | False | None | None | False | None | False | 1107.0 | 0 | 3513171 | 125946 | None | code09 | Supplying and flush mounting powder coated or galvanized
metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 1-3Way8Way | Each | 250.0 | 250.0 | 3.0 | False | None | None | False | None | False | 750.0 | 0 | 3513172 | 125946 | None | code10 | Supplying and flush mounting powder coated or galvanized
metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 1-3Way10 12Way | Each | 325.0 | 325.0 | 15.0 | False | None | None | False | None | False | 4875.0 | 0 | 3513173 | 125946 | None | code11 | Supplying and flush mounting powder coated or galvanized
metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 1-3Way | Each | 152.0 | 152.0 | 9.0 | False | None | None | False | None | False | 1368.0 | 0 | 3513174 | 125946 | None | code12 | Supplying and flush mounting powder coated or galvanized
metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 1-3Way8Moudule | Each | 302.0 | 302.0 | 3.0 | False | None | None | False | None | False | 906.0 | 0 | 3513175 | 125946 | None | code13 | Supplying and flush mounting powder coated or galvanized
metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 1-3Way12Moudule | Each | 403.0 | 403.0 | 6.0 | False | None | None | False | None | False | 2418.0 | 0 | 3513176 | 125946 | None | code14 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Using Group "A" materials 6Amps one way. | Each | 88.0 | 88.0 | 48.0 | False | None | None | False | None | False | 4224.0 | 0 | 3513177 | 125946 | None | code15 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Using Group "A" materials 6Amps one way. Stepped Fan Regulator. | Each | 313.0 | 313.0 | 12.0 | False | None | None | False | None | False | 3756.0 | 0 | 3513178 | 125946 | None | code16 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Using Group "A" materials 6Amps one way. 16Amps one way switch | Each | 249.0 | 249.0 | 18.0 | False | None | None | False | None | False | 4482.0 | 0 | 3513179 | 125946 | None | code17 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Using Group "A" materials 6Amps one way. 32Amps DP switch | Each | 375.0 | 375.0 | 6.0 | False | None | None | False | None | False | 2250.0 | 0 | 3513180 | 125946 | None | code18 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Using Group "A" materials 6Amps one way. 6or16Amps universal socket | Each | 249.0 | 249.0 | 12.0 | False | None | None | False | None | False | 2988.0 | 0 | 3513181 | 125946 | None | code19 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Using Group "A" materials 6Amps one way. 6Amps 3way socket. | Each | 162.0 | 162.0 | 12.0 | False | None | None | False | None | False | 1944.0 | 0 | 3513182 | 125946 | None | code20 | Supplying of feet PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours and 70percent lumen maintenance with CRI greater than 80. Power Input: 220-240Vat 50or60Hz and Power factor greater than0.9 along with CE approved. years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4'- 20or22 w Each. LED light fitting 1 x 4'- 20 or 22 w Each
| Each | 740.0 | 740.0 | 20.0 | False | None | None | False | None | False | 14800.0 | 0 | 3513183 | 125946 | None | code21 | Supplying and fixing of Porcelain fuse channel with cut out on existing woodenorpanel using necessary nuts,bolts and
washers.32Amps | Each | 200.0 | 200.0 | 3.0 | False | None | None | False | None | False | 600.0 | 0 | 3513184 | 125946 | None | code22 | Supplying and fixing regular MCB distribution boards on
wallorood board or flush mounting using required clA, bolts,
nuts etc., with provision for fixing suitable type capacity
MCB's single phaseor3 phaseorsingle door with powder coated painting Made out of 14 SWG MS enclosure.a) 6-32Amps SP Group 'A' | Each | 523.0 | 523.0 | 3.0 | False | None | None | False | None | False | 1569.0 | 0 | 3513185 | 125946 | None | code23 | Supplying and fixing regular MCB distribution boards on
wallorood board or flush mounting using required clA, bolts,
nuts etc., with provision for fixing suitable type capacity
MCB's single phaseor3 phaseorsingle door with powder coated painting Made out of 14 SWG MS enclosure.a) 6-32Amps SP Group 'A'6-32 Amps DP Group 'A' | Each | 1103.0 | 1103.0 | 3.0 | False | None | None | False | None | False | 3309.0 | 0 | 3513186 | 125946 | None | code24 | Supplying and fixing regular MCB distribution boards on wall or wood board or flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase or 3 phase or single door with powder coated painting. Made out of 14 SWG MS enclosure.II - Double Door a) 4Way SP andN | Each | 1368.0 | 1368.0 | 3.0 | False | None | None | False | None | False | 4104.0 | 0 | 3513187 | 125946 | None | code25 | GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long,3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg | No | 770.0 | 770.0 | 3.0 | False | None | None | False | None | False | 2310.0 | 0 | 3513188 | 125946 | None | code26 | Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each | No | 660.0 | 660.0 | 3.0 | False | None | None | False | None | False | 1980.0 | 0 | 3513189 | 125946 | None | code27 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag | Bag | 303.0 | 303.0 | 3.0 | False | None | None | False | None | False | 909.0 | 0 | 3513190 | 125946 | None | code28 | Digging of Pit for providing GI Pipe type Earthing LABOUR RATE | Per Pit | 2267.0 | 2267.0 | 3.0 | False | None | None | False | None | False | 6801.0 | 0 | 3513191 | 125946 | None | code29 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system and as per technical data approved.48" Sweep (1200mm) Regular model | Each | 2085.0 | 2085.0 | 12.0 | False | None | None | False | None | False | 25020.0 | 0 | 3513192 | 125946 | None | code30 | Supply and fixing polished wood board made of not less
than 15mm thick plank on both sides of not more than 2
pieces and fixing the same to the wall using tapered inverted wooden plugs screws.8"x6"1.5" | Each | 76.0 | 76.0 | 3.0 | False | None | None | False | None | False | 228.0 | 0 | 3513193 | 125946 | None | code31 | Supply and fixing polished wood board made of not less
than 15mm thick plank on both sides of not more than 2
pieces and fixing the same to the wall using tapered inverted wooden plugs screws.8"x6"1.5"12"x12"2" | Each | 162.0 | 162.0 | 3.0 | False | None | None | False | None | False | 486.0 | 0 | 3513194 | 125946 | None | code32 | Fixing all types and all capacities of fluorescent orfalse ceiling orspot light or CFL or LED fittings indoor on the wallor ceiling orrafters or girders using 23or0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.On wall or ceiling or Rafter or Girders | Each | 119.0 | 119.0 | 8.0 | False | None | None | False | None | False | 952.0 | 0 | 3513195 | 125946 | None | code33 | Fixing a ceiling orwall mounting fan of all capacities and all
types, with necessary clA and 'S' hook made out of 15mm dia
MS rod, with 5 A. ceiling rose of approved quality with
necessary length of 23or0.0076 inch PVC insulated twin twisted
wire of approved quality, mounted on a suitable size wooden
board and wired. | Each | 281.0 | 281.0 | 6.0 | False | None | None | False | None | False | 1686.0 | 0 | 3513196 | 125946 | None | code34 | Supplying PVCorGI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely 20mm | Mtr | 25.0 | 25.0 | 6.0 | False | None | None | False | None | False | 150.0 | 0 |
|
|
---|