| 1720779402000 | 0 | None | None | Bridges/Culverts | Construction Of RCC Culverts in Bettadasanapura Main Rod And 3rd cross to 9th Cross In Bettadasanapura Main Road And EXTENTION OF UGD LineIn TP Dodda Thoguru Panchayath LIMIT. | 1261029.7 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3515514 | 126099 | None | pwd 1 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing of the excavated stuff or sorting & stacking the selected stuff for reuse lin a radius of 50 m and lift up to 1.5 m including cost of labour, tools & other appurtenances required to complete the work ---- PWD LICENCE | Cum | 249.26 | 249.26 | 75.6 | False | None | None | False | None | False | 18844.056 | 0 | | 3515515 | 126099 | None | pwd 2 | Removal of Unserviceable Soil with Disposal upto suitable distance as directed by the Engineer incharge of work ---- PWD LICENCE | Cum | 87.55 | 87.55 | 75.6 | False | None | None | False | None | False | 6618.78 | 0 | | 3515516 | 126099 | None | pwd 3 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications ---- PWD LICENCE | Cum | 6168.67 | 6168.67 | 13.0 | False | None | None | False | None | False | 80192.71 | 0 | | 3515517 | 126099 | None | pwd 4 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation lworks, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges lof machinery, curing and all other appurtenances required to complete the work as per technical specifications. ---- PWD LICENCE | Cum | 8792.13 | 8792.13 | 55.44 | False | None | None | False | None | False | 487435.6872 | 0 | | 3515518 | 126099 | None | pwd 5 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire l soft annealed steel wire and other ancilary operations complete as per drawing and technical specification ---- PWD LICENCE | Cum | 81381.33 | 81381.33 | 5.54 | False | None | None | False | None | False | 450852.5682 | 0 | | 3515519 | 126099 | None | pwd 6 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavat ed surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m in cluding cost of labour, tools, usage& other appurtenances required to complete the work. ---- PWD LICENCE | Cum | 498.52 | 498.52 | 70.0 | False | None | None | False | None | False | 34896.4 | 0 | | 3515520 | 126099 | None | pwd 7 | Supplying lowering laying, jointing, testing and commissioning of following diameters glazed stone ware pipes, conforming to IS 651:1992, (with 5th revision) in all respects jointing with EPDM rubber rings (seals according to EN 681 & ASPM 425) The rubber seals joints pipe will have groves in interior of socket and exterior of the spigot. The rubber gasket shall be prefixed at the factory by the manufacture rigidly with approved glue to have leak proof joint including conveying of pipe to work site and rolling and lowering into trenches, laying true to line, level and perfect linking at joints testing and commissoning including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of GSW pipes and specials, with rubber gaskets conforming to EN 681 and ASTM C-425 including cleaning the socket and spigot with soap solution and applying talcum powder for detecting crack, then applying glue and before inserting of rubber gaskets, jacking and fixing in perfect condition including the cost of soap solution, talcum powder and glue etc. and giving necessary hydraulic test to the required pressure of water head with all lead and lifts including costing of jointing materials and all necessary survey works for laying of sewers etc., and disposal of debris as directed etc., complete ---- PWD LICENCE | Mtr | 908.46 | 908.46 | 70.0 | False | None | None | False | None | False | 63592.2 | 0 | | 3515521 | 126099 | None | pwd 8 | Providing and constructing of Machinehole chambers conical in shape at top with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15m alround the chamber and brick masonry in C.M 1:4 plaster with bricks of approved quality and CM plaster 1:3 proportion 12mm thick inside and outside except for the conical surface outside where the thickness of plaster shall be 20 mm thick, with 1 to 6 slope in the concrete towards the central drain, finished smooth and fixing of pipes in CC 1:2:4 with graded metal of 20 mm and down size including Providing and fixing SFRC Machinehole frame and cover confoming to IS 12592(Part-I): 1988 & IS 12592(Part-II) :1991 with latest amendments in CC 1:2:4, Providing and fixing of plastic foot steps staggered at 30cms apart as directed, watering, curing,barricading, danger lighting, pouring tar over M.H. frame and cover, cost of tar, shoring, strutting, dewatering, engraving Machinehole No. on the inner and outer conical surface etc. as per the drawing with all lead and lift for various diameters and depths noted below. With Laterite Bricks & Medium Duty cover and frame.For 16.42.2 Constructing Table Moulded Bricks Machinehole ---- PWD LICENCE | Nos | 39532.43 | 39532.43 | 3.0 | False | None | None | False | None | False | 118597.29 | 0 |
|