createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1720450244838
version10
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd760000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose05-08-2024 16:00:00
tenderQueryClose01-08-2024 17:30:00
technicalBidOpen07-08-2024 16:30:00
publishedDate16-07-2024 10:30:45
publishedByPostPWD_EE_DIV_KLB
publishedByUserKPE14204 - SUBHASH L SHIXNAKAR
bidValidityPeriod90
noOfCalls1
preBidMeetingDate22-07-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonExecutive Engineer PWD Division Kalaburagi
splitEmdRequiredYnTrue
emdBankGuarantee660000.00
emdCash100000.00
bgValidityPeriod135
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber0847225652
mobileNumber9448652632
tenderSupplierListNone
tenderSchedule
createdTs1720450244876
version9
createdDateNone
modifiedDateNone
tenderNumberPWD/2024-25/BD/WORK_INDENT11086
titleConstruction of Freedom Fighter s Bhavan (Continuation Work) in Kalaburagi City for the Year 2023-24
descriptionConstruction of Freedom Fighter s Bhavan (Continuation Work) in Kalaburagi City for the Year 2023-24
categoryWORKS
categoryTextWorks
ecv50422718.43
deptNamePublic Works Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location1689
locationNamePWD Division Office Kalaburagi
provisionalAmount59500000.0
groupOverheadTotal0.0
fileNumber2024-25-EST-KALB-YAMPURE-09
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17204502450001NoneNoneBuildingsCivil Work40340014.74
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3486751124663NoneDSR It. No. 6.8 Vol-2 Pg. No. 14Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Sqm8367.458367.45158.45FalseNoneNoneFalseNoneFalse1325822.45250
3486752124663NoneDSR It. No.7.38 Vol-2 Pg. No. 26Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin- charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. Sqm596.4596.4184.8FalseNoneNoneFalseNoneFalse110214.720
3486753124663NoneDSR It. No. 8.1.1 Vol-2 Pg. No. 41Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of ngineer-in-charge.Sqm267.75267.751302.43FalseNoneNoneFalseNoneFalse348725.63250
3486754124663NoneDSR It. No. 2.1.4 Vol-1 Pg. No. 59Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse ggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm and down size graded crushed coarse aggregates Cum6527.856527.8592.47FalseNoneNoneFalseNoneFalse603630.28950
3486755124663NoneDSR It No.15.9 Vol-2 Pg No.151Providing and Applying Polyurethane hybrid liquid applied GRIHA certified Waterproofing coating with flutyne protection technology, single component, cold applied, water based acrylic and UV resistant water proofing treatment to the Existing Roof having Tile or any non-porous surface applied 1.5 l m2 in 2 coats to achieve 1mm DFT, having tensile strength with 45 gsm glass fibre mesh 4N.mm2 confirming to ASTM D412 Elongation at break 300 and Crack bridging ability up to 3mm, SRI Index 106 as per ASTM E 1980-01, Water permeability 5 bar Nil as per EN12390 - 8:2019, including surface preparation, priming the surface with single component high-performance waterborne tile primer which is suitable for non - porous surface at a rate of 0.083 L/m2 and spreading 45 gsm glass fibre mesh of 2.5 mm x 2.5 mm sandwiched between the first and second coat completely as per specification. The finished cost to include surface preparation, making coving at Junction, treatment of cracks completely as per specifispecificationSqm1009.051009.05650.04FalseNoneNoneFalseNoneFalse655922.8620
3486756124663NoneDSR It. No. 13.49 Vol-2 Pg. No. 125Providing and fixing on wall face unplasticised Rigid PVC rain water pipes of 150mm dia conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes Mtr596.4596.4448.0FalseNoneNoneFalseNoneFalse267187.20
3486757124663NoneDSR It. No. 13.37 Vol-2 Pg. No. 123Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.Nos328.65328.6556.0FalseNoneNoneFalseNoneFalse18404.40
3486758124663NoneDSR It. No. 12.12 Vol-2 Pg. No. 99Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications Cum130412.1130412.10.16FalseNoneNoneFalseNoneFalse20865.9360
3486759124663NoneDSR It. No. 12.18 Vol-2 Pg. No.100Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with, stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures ) Sqm6904.86904.86.72FalseNoneNoneFalseNoneFalse46400.2560
3486760124663NoneDSR It. No.12.13.2 Vol-2 Pg. No. 100Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. Cum104580.0104580.09.98FalseNoneNoneFalseNoneFalse1043708.40
3486761124663NoneDSR It. No. 20.21 Vol-2 Pg. No. 199Providing and fixing Teak wood plain jaffri door and window shutters including bright or/and black enamelled M.S. butt hinges with necessary screws 35x10 mm laths placed 35 mm apart (frames to be paid separately), including fixing 50x12 mm beading complete with : Sqm4320.754320.7547.91FalseNoneNoneFalseNoneFalse207007.13250
3486762124663NoneDSR It. No.11.30.2 Vol-2 Pg. No.85Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 5.5 mm thick glass panes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. Sqm1320.91320.9450.9FalseNoneNoneFalseNoneFalse595593.810
3486763124663NoneDSR It. No.11.52 Vol-2 Pg. No.94Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc. to be paid separately) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm4958.14958.112.81FalseNoneNoneFalseNoneFalse63513.2610
3486764124663NoneDSR It. No.8.34.1 Vol-2 Pg. No.47Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm55.6555.652638.94FalseNoneNoneFalseNoneFalse146857.0110
3486765124663NoneDSR It. No. 8.33.2 Vol-2 Pg. No. 46Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @0.75 L/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm144.9144.92655.74FalseNoneNoneFalseNoneFalse384816.7260
3486766124663NoneDSR It. No.3.2 Vol-1 Pg. No. 23Providing Cement mortar 1:2 (1 cement : 2 fine sand) including cost of all materials, labour and usage charges of machinery complete as per the direction of engineer incharge of work. Cum8422.658422.6551.46FalseNoneNoneFalseNoneFalse433429.5690
3486767124663NoneDSR It. No. 8.27 Vol-2 Pg. No. 45Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm55.6555.65558.25FalseNoneNoneFalseNoneFalse31066.61250
3486768124663NoneDSR It. No. 8.27 Vol-2 Pg. No. 45Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm55.6555.65492.25FalseNoneNoneFalseNoneFalse27393.71250
3486769124663NoneDSR It. No. 8.27 Vol-2 Pg. No. 45Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm66.2566.251884.1FalseNoneNoneFalseNoneFalse124821.6250
3486770124663NoneDSR It. No. 20.50 Vol-2 Pg. No. 203Removing white wash or colour wash by steel brushing and / or scraping, sand papering and preparing wall surface smooth including repairs to scraches including cost of labour, material complete as per specifications. Sqm13.6513.652947.26FalseNoneNoneFalseNoneFalse40230.0990
3486771124663NoneDSR It. No. 20.50 Vol-2 Pg. No. 203Removing white wash or colour wash by steel brushing and / or scraping, sand papering and preparing wall surface smooth including repairs to scraches including cost of labour, material complete as per specifications. Sqm13.6513.652148.01FalseNoneNoneFalseNoneFalse29320.33650
3486772124663NoneDSR It. No. 20.50 Vol-2 Pg. No. 203Removing white wash or colour wash by steel brushing and / or scraping, sand papering and preparing wall surface smooth including repairs to scraches including cost of labour, material complete as per specifications. Sqm16.2516.25458.37FalseNoneNoneFalseNoneFalse7448.51250
3486773124663NoneDSR It. No. 8.33.1 Vol-2 Pg. No. 46Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life) Sqm165.9165.92947.26FalseNoneNoneFalseNoneFalse488950.4340
3486774124663NoneDSR It. No. 8.33.1 Vol-2 Pg. No. 46Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life) Sqm165.9165.92148.01FalseNoneNoneFalseNoneFalse356354.8590
3486775124663NoneDSR It. No. 8.33.1 Vol-2 Pg. No. 46Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life) Sqm197.5197.5458.37FalseNoneNoneFalseNoneFalse90528.0750
3486776124663NoneDSR It. No. 8.29 Vol-2 Pg. No. 45Finishing walls with textured exterior paint of required shade :New work(Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm297.15297.15843.26FalseNoneNoneFalseNoneFalse250574.7090
3486777124663NoneDSR It. No. 8.29 Vol-2 Pg. No. 45Finishing walls with textured exterior paint of required shade :New work(Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm297.15297.151201.61FalseNoneNoneFalseNoneFalse357058.41150
3486778124663NoneDSR It. No. 8.29 Vol-2 Pg. No. 45Finishing walls with textured exterior paint of required shade :New work(Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm353.75353.752717.68FalseNoneNoneFalseNoneFalse961379.30
3486779124663NoneDSR It. No. 11.26.2 Vol-2 Pg. No. 84Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. E.R.W. tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kgs136.5136.53742.2FalseNoneNoneFalseNoneFalse510810.30
3486780124663NoneDSR It. No. 8.33.3 Vol-2 Pg. No. 47Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm145.95145.952566.08FalseNoneNoneFalseNoneFalse374519.3760
3486781124663NoneDSR It. No. 11.31 Vol-2 Pg. No. 86Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge including cost of materials, labour, usage charges of machinery complete as per specifications. Kgs118.65118.653035.21FalseNoneNoneFalseNoneFalse360127.66650
3486782124663NoneDSR It. No. 7.66 Vol-2 Pg. No. 37Providing & Fixing of High Acoustical False Ceiling having NRC (Noise Reduction Coefficient) 0.90 (minimum) using Integral Densified edged Eco Friendly Fully Perforated Lightweight Calcium Silicate False Ceiling Tiles with Suitable to Modular Grid Size of 600x600mm with PPGI Slimline profile Balck/White reveal T 15 Grid system for Auditoriums, Community halls, Lecture Halls, Airports, Offices, Factories and All other High Acoustics required buildings.The Fully Perforated Lightweight Calcium Silicate False Ceiling tiles shall be made from Non Cementitious Hydrated Calcium Silicate Slurry/Mixture, Reinforced recycled material with fibers and natural fillers. Free from Formaldehyde and other harmful materials. Doesn't contain any toxic ingrediants. The thickness of tiles should be 15mm at all around the edge resting portion with integral densified edge and 10mm thick at the quadrant. The tiles should have fiber glass fleece on rear side along with backing of 50mm thick rockwool slabs of density 48kg/m3 to achieve NRC 0.90 (Minimum). The tiles should have Humidity Resistance (RH) of 100%, Water Resistance, Non Combustible as per BS:476 Part-4, Fire Performance: Fire Propagation as per BS:476 Part-6, Class-1 for Surface Spread of Flame as per BS:476 Part7, Class A or Class 1 as per ASTM E 84, Thermal Conductivity K= 0.048 to0.052 w/m K as per ECBC code 2007, Size of the tile is 595x595mm, Density of tile should be 450 kg/m3 density all around on edge resting portion and 350kg/m3 density at the Quadrant, Light Reflectance 85%, Weight of the tile is 5-5.5 kg/m2 and Suitable for Green Building application with InOrganic Recycled content of 50% and meets the GRIHA norms under the categories: GRIHA V.2015 criterion:11&12, GRIHA V.3 criterion: 17&29 and SVAGRIHA criterion:12. The tiles Shall be laid on 15mm wide Polyester Powder Coated Galvanized Iron (PPGI) Slimline Profile Black/White reveal T-Sections Flanges colour white having rotary stitching double webbed on all T sections. The framework shall comprise of Main T runner with a web height of 38mm and 1200mm & 600mm Cross Tees with a web height of 38mm having sheet thickness of 0.4mm. The T sections should have Galvanizing of 120 g/m2 and need to be installed with Suspension system consisting of 12x50mm long dash fastners, Z cleat 25x37x25x1.6mm with pre cut hole on both 25mm flange to accomdate the 6mm dia bolt of the fasterner on one flange and 6mm fully threaded hanger rod uptom 1000mm length on the other. L-shape level adjuster of size 76x25x1.6mm to be fixed with T grid main runner. The entire grid rests on the perphery on a pre coated GI wall angle of size 15x20mm of sheet thickness 0.40mm of length 3000mm to be fixed on periphery wall/partition with the help of plastic rawl plugs at 450mm center to centerand 40mm long s.s screws. The work shall be carried out as per specifications, drawings and asper direction of Engineer in ChargESqm2784.152784.151743.04FalseNoneNoneFalseNoneFalse4852884.8160
3486783124663NoneDSR It. No. 10.13.2 Vol-2 Pg. No. 70Providing and fixing skirting with teak shade pre-laminated (one side decorative and other side balancing lamination) flat pressed 3 layer or graded particle board (medium density) Grade I, Type II, IS :12823 marked, with necessary fixing arrangements and screws, including drilling necessary holes for rawl plugs etc. and priming coat on unexposed surface complete :25 mm thick Sqm2096.852096.85312.6FalseNoneNoneFalseNoneFalse655475.310
3486784124663NoneDSR It. No. 7.58 Vol-2 Pg. No. 35d1 Providing and supplying 'Acoustical Wall Paneling' with square edges made of fibre glass substrate 25mm thick and wrapped on the front side with an acoustically transparent and classified for Fire reaction Class A, as per ASTM E-84, fabric with option of colors - as per the choice of the architect/Engineer incharge of the size 600x600mm, 600x1200mm & 600x1800mm providing a minimum sound absorption level of 0.85 NRC to be affixed to wall using Wall panel lmpaler sand construction adhesives as per the instructions laid down by the certified manufacturer. Sqm6013.356013.35471.97FalseNoneNoneFalseNoneFalse2838120.79950
3486785124663NoneDSR It. No. 22.28 Vol-2 Pg. No.220Providing & supplying Carpet/Mat of 800+ gsm with stain proof, flexible and super absorbent fibre of good quality as per direction of Engineer in charge. Sqm1470.01470.01755.23FalseNoneNoneFalseNoneFalse2580188.10
3486786124663NoneDSR It. No. 11.3 Vol-2 Pg. No.77Seating Supplying & Installing amest cladding layered fabric Floor mounted seat with auto tip up mechanism with push back feature Moulded PU with integrated MS structure made up of 25mm dia pipe of 2mm thickness HRCA 2mm thick MS tubular framework (conforming to IS:1079/1994 type O)welded together with continuous mig welding.single footrest 80mmX40mmX2mm mounting C frame 3mm thick MS for seat tip up seat width 10mm 480 millimeter seat depth 10mm 460mm Seat thickness(including cushion)10mm 130mm Backrest width 10mm 450mm Backrest height 10mm 750mm Both sides Armrest mounted on 8mm thick fabricated arm duly fitted with PPCP Box covered by fabric laminated foam Fabric cladded PPCP box type common armrest(with option for integrating conforming system) Complete as per specification and directions of the engineer incharge.Nos16800.016800.0800.0FalseNoneNoneFalseNoneFalse13440000.00
3486787124663NoneDSR It. No. 11.3 Vol-2 Pg. No.77Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Sqm8689.88689.89.0FalseNoneNoneFalseNoneFalse78208.20
3486788124663NoneDSR It. No. 12.75.3 Vol-2 Pg. No.107Providing and fixing bright finished brass butt hinges with necessary screws etc. complete :100x85x5.5 mm (heavy type) Nos215.25215.2578.0FalseNoneNoneFalseNoneFalse16789.50
3486789124663NoneDSR It. No. 12.76.2 Vol-2 Pg. No.107Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete 200x10mm Each367.5367.552.0FalseNoneNoneFalseNoneFalse19110.00
3486790124663NoneDSR It. No. 12.79.1 Vol-2 Pg. No.108Providing and fixing bright finished brass handles with screws etc. complete:Brass handles 125 mm with plate 175x32 mm Each261.45261.4552.0FalseNoneNoneFalseNoneFalse13595.40
3486791124663NoneDSR It. No. 12.80.1 Vol-2 Pg. No.108Providing and fixing door latch with necessary screws etc complete.Bright finished brass latch Each299.25299.2552.0FalseNoneNoneFalseNoneFalse15561.00
3486792124663NoneDSR It. No. 1.2 Vol-1 Pg. No.5Earth work in surface excavation for stripping, seating of bund, Road way by manual means for lowering & levelling the ground for all works other than foundation & depth in Ordinary rock and soft rock upto 300mm depth as per drawing and technical specifications, including setting out, barricading, aution lights, including dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. Cum603.75603.75640.58FalseNoneNoneFalseNoneFalse386750.1750
3486793124663NoneDSR It. No. 4.17 Vol-3 Pg. No.26Wet Mix Macadam (Plant Mix Method) Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. Cum2686.952686.95412.2FalseNoneNoneFalseNoneFalse1107560.790
3486794124663NoneDSR It. No. 2.1.4 Vol-1 Pg. No.15Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates Cum6527.856527.855.25FalseNoneNoneFalseNoneFalse34271.21250
3486795124663NoneDSR It. No. 9.25 Vol-2 Pg. No.63Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse and, filling the joints with fine sand etc. all omplete as per the direction of Engineer-in-charge. Sqm840.0840.01441.0FalseNoneNoneFalseNoneFalse1210440.00
3486796124663NoneDSR It. No. 9.35 Vol-2 Pg. No.64Flooring with 25mm thick polished shahabad slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. Sqm1717.81717.8620.0FalseNoneNoneFalseNoneFalse1065036.00
3486797124663NoneDSR It. No. 8.42.3 Vol-3 Pg. No.74Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge.(The cost of PCC shall be paid extra) 600 x 300 x 150 mm size Mtr486.15486.15178.0FalseNoneNoneFalseNoneFalse86534.70
3486798124663NoneDSR It. No. 19.2.1 Vol-2 Pg. No.187Modification of Stage Step Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge. Cum1746.151746.150.65FalseNoneNoneFalseNoneFalse1134.99750
3486799124663NoneDSR It. No. 6.4 Vol-2 Pg. No.13Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work Cum9094.059094.052.05FalseNoneNoneFalseNoneFalse18642.80250
3486800124663NoneDSR It. No.1.8 Vol-1 Pg. No.33Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage & all other appurtenaces required to complete the work. Cum497.7497.72.05FalseNoneNoneFalseNoneFalse1020.2850
3486801124663NoneDSR It. No. 2.1.4 Vol-1 Pg. No.15Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates Cum6527.856527.854.64FalseNoneNoneFalseNoneFalse30289.2240
3486802124663NoneDSR It. No. 8.6.2 Vol-2 Pg. No. 42Providing 20 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/ stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm450.45450.458.0FalseNoneNoneFalseNoneFalse3603.60
3486803124663NoneDSR It. No. 11.28 Vol-2 Pg. No. 85Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Kg593.25593.25155.0FalseNoneNoneFalseNoneFalse91953.750
3486804124663NoneDSR It. No. 3.5 Vol-3 Pg. No. 17Scarifying the existing bituminous road surface to a depth of 50 mm and disposal of scarified material by Mechanical Means using Hydraulic excavator with in all lifts and lead Sqm6.36.3671.0FalseNoneNoneFalseNoneFalse4227.30
3486805124663NoneDSR It. No. 3.7 Vol-3 Pg. No. 17Compacting original ground supporting embankment:Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry ensity as given in Table 300-2 for embankment construction. Cum110.25110.25100.65FalseNoneNoneFalseNoneFalse11096.66250
3486806124663NoneDSR It. No. 4.1.A (V) Vol-3 Pg. No. 23Plant Mix Method Construction of Granular Sub-Base of required grading as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired ensity, complete as per clause 401 For Grading -V Material Cum2611.352611.3550.32FalseNoneNoneFalseNoneFalse131403.1320
3486807124663NoneDSR It. No. 4.7 Vol-3 Pg. No. 26Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well repared surface and compacting with vibratory roller to achieve the desired density Cum2686.952686.95100.65FalseNoneNoneFalseNoneFalse270441.51750
3486808124663NoneDSR It. No. 5.1.A(i) Vol-3 Pg. No. 31Providing and applying primer coat with SS1 grade Bitumen Emulsion on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70 kg/m2 using mechanical means. Cum43.0543.05671.0FalseNoneNoneFalseNoneFalse28886.550
3486809124663NoneDSR It. No. 5.6.i(C) Vol-3 Pg. No. 32Providing and laying Bituminous Macadam with 40/60 tph capacity hot mix plant using crushed aggregates of specified grading premixed with bituminous binder VG-30 @ 3.3% by weight of mix, transported to site, laid over a previously prepared surface with mechanical paver finisher to the required rade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction Cum7835.17835.133.55FalseNoneNoneFalseNoneFalse262867.6050
3486810124663NoneDSR It. No. 5.31 Vol-3 Pg. No. 43Providing and laying Semi Dense Bituminous Concrete with 40/60 TPH capacity hot mix plant batch type using crushed aggregates of specified grading premixed with bituminous binder VG-30 @ 5% by weight of mix and filler, transported to site, laid over a previously prepared surface with mechanical aver finisher to the required grade, level and alignment and rolled as per MoRTH V revision. Cum10659.610659.616.78FalseNoneNoneFalseNoneFalse178868.0880
3486811124663NoneDSR It. No. 2.5.1 Vol-1 Pg. No. 16Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine ixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per echnical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Cum10276.510276.55.25FalseNoneNoneFalseNoneFalse53951.6250
3486812124663NoneDSR It. No. 2.5.1 Vol-1 Pg. No. 16Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings Tonne93929.8593929.850.42FalseNoneNoneFalseNoneFalse39450.5370
3486813124663NoneDSR It. No. 9.19 Vol-2 Pg. No. 61Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser, treads of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints as per direction of Engineer in charge. Sqm1231.651231.65323.12FalseNoneNoneFalseNoneFalse397970.7480
3486814124663NoneDSR It. No.10.1.2 Vol-2 Pg. No. 69Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2 Sqm4133.854133.857.87FalseNoneNoneFalseNoneFalse32533.39950
3486815124663NoneDSR It. No.14.10.1.1 Vol-2 Pg.No. 133Providing and fixing Stainless Steel A ISI 04 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 510x1040 mm bowl depth 250 mm No5898.95898.91.0FalseNoneNoneFalseNoneFalse5898.90
3486816124663NoneDSR It. No.12.66.2 Vol-2 Pg.No. 106Providing and fixing chromium plated brass curtain rod with ISI mark having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete 20mm dia m685.65685.6512.0FalseNoneNoneFalseNoneFalse8227.80
3486817124663NoneDSR It. No.22.24 Vol-2 Pg.No. 219Providing & fixing 100% Polyester Curtains with specification of regular wash as per direction of Engineer in charge Sqm1260.01260.048.0FalseNoneNoneFalseNoneFalse60480.00
3486818124663NoneDSR It. No.9.36 Vol-2 Pg. No. 64Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, olishing complete as per specifications. Sqm1732.51732.513.77FalseNoneNoneFalseNoneFalse23856.5250
17204502450000NoneNoneBuildingsWaterSupply & Sanitary Works644795.54
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3486819124664NoneDSR It. No.12.4 Vol-5 Pg. No.140BOREWELL "Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield tes" Each5552.45552.42.0FalseNoneNoneFalseNoneFalse11104.80
3486820124664NoneDSR It. No.12.1.1 Vol-5 Pg. No.139Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) Borewell depth 0.0 to 50 mtr (Above 450m of drilling add 10% for every 50m depth) Mtr388.5388.550.0FalseNoneNoneFalseNoneFalse19425.00
3486821124664NoneDSR It. No.12.1.2 Vol-5 Pg. No.139Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) Borewell depth of 50 to 100 Mtrs (Above 450m of drilling add 10% for every 50m depth) Mtr487.2487.250.0FalseNoneNoneFalseNoneFalse24360.00
3486822124664NoneDSR It. No.12.1.2 Vol-5 Pg. No.139Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) Borewell depth of 100 to 150 Mtrs (Above 450m of drilling add 10% for every 50m depth) Mtr517.65517.6525.0FalseNoneNoneFalseNoneFalse12941.250
3486823124664NoneDSR It. No.17.6.3 Vol-2 Pg. No.175Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270,of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. Mtr1970.851970.856.0FalseNoneNoneFalseNoneFalse11825.10
3486824124664NoneDSR It. No.17.9.3 Vol-2 Pg. No.176Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of 200 mm dia Each266.7266.71.0FalseNoneNoneFalseNoneFalse266.70
3486825124664NoneDSR It. No.10.2.4 Vol-5 Pg. No.114Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc.Complete for Pipes of SN4, 160mm dia. Mtr604.8604.8125.0FalseNoneNoneFalseNoneFalse75600.00
3486826124664NoneDSR It. No.13.9.2 Vol-5 Pg. No.150Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc complete 3.00 HP/2.2KW 15 STGEach22606.522606.51.0FalseNoneNoneFalseNoneFalse22606.50
3486827124664NoneDSR It. No.13.22.2 Vol-5 Pg. No.154Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments.1x3x2.5 Sqm Mtr89.2589.25140.0FalseNoneNoneFalseNoneFalse12495.00
3486828124664NoneDSR It. No.13.31 Vol-5 Pg. No.155Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. Mtr42.042.0128.0FalseNoneNoneFalseNoneFalse5376.00
3486829124664NoneDSR It. No.13.32 Vol-5 Pg. No.156Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. Job6825.06825.01.0FalseNoneNoneFalseNoneFalse6825.00
3486830124664NoneDSR It. No.9.1.1 Vol-5 Pg. No.95Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0HDPE Grade PE80-PN6.0, 63mm dia Mtr198.45198.45125.0FalseNoneNoneFalseNoneFalse24806.250
3486831124664NoneDSR It. No.13.25 Vol-5 Pg. No.154Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments . Each1312.51312.51.0FalseNoneNoneFalseNoneFalse1312.50
3486832124664NoneDSR It. No.13.24.1 Vol-5 Pg. No.155Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete.Upto 3 HP pumps Job7875.07875.01.0FalseNoneNoneFalseNoneFalse7875.00
3486833124664NoneDSR It. No.13.34 Vol-5 Pg. No.156Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer incharge of work. Job1522.51522.51.0FalseNoneNoneFalseNoneFalse1522.50
3486834124664NoneDSR It. No.13.25 Vol-5 Pg. No.155Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets. Kvar577.5577.51.0FalseNoneNoneFalseNoneFalse577.50
3486835124664NoneDSR It. No.13.26 Vol-5 Pg. No.155Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box. Per 3 Poles1207.51207.51.0FalseNoneNoneFalseNoneFalse1207.50
3486836124664NoneDSR It. No.13.35.2 Vol-5 Pg. No.156Labour charges for providing connection using insulated sheathed steel wire cable as per IS 1554/ 1988 with latest amendments from KPTCL pole to meter board unit, with all necessary materials ,tools and equipments,as per specificationswith testing of as per instructions of engineer incharge of work. 3.5 x 16 sqmm (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.35.2 page no.156)Mtr168.0168.065.0FalseNoneNoneFalseNoneFalse10920.00
3486837124664NoneDSR It. No.11.2.6 Vol-5 Pg. No.127Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) Medium Duty GI pipe of 50mm dia. Mtr613.2613.265.0FalseNoneNoneFalseNoneFalse39858.00
3486838124664NoneDSR It. No.13.39 Vol-5 Pg. No.157Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.39 page no.157) Job3937.53937.51.0FalseNoneNoneFalseNoneFalse3937.50
3486839124664NoneDSR It. No.10.1.1 Vol-5 Pg. No.113Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. PVC pipes 25mm dia, 10 kg/sqcm & class 5 Mtr50.450.4410.0FalseNoneNoneFalseNoneFalse20664.00
3486840124664NoneDSR It. No.13.4.1 Vol-2 Pg. No.117Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :25 mm nominal bore Nos576.45576.458.0FalseNoneNoneFalseNoneFalse4611.60
3486841124664NoneDSR It. No.13.2.2 Vol-2 Pg. No.117Providing and fixing brass bib cock of approved quality :20 mm nominal bore Nos320.25320.2540.0FalseNoneNoneFalseNoneFalse12810.00
3486842124664NoneDSR It. No.14.4.1 Vol-2 Pg. No.131Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern Nos4676.74676.713.0FalseNoneNoneFalseNoneFalse60797.10
3486843124664NoneDSR It. No.14.2.1 Vol-2 Pg. No.131Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid Nos5079.95079.94.0FalseNoneNoneFalseNoneFalse20319.60
3486844124664NoneDSR It. No.14.1.1 Vol-2 Pg. No.131Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixturescomplete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests Nos5079.95079.96.0FalseNoneNoneFalseNoneFalse30479.40
3486845124664NoneDSR It. No.13.55 Vol-2 Pg. No.127Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 600X850 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc.complete as per standard design: Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets : With common burnt clay (non modular) bricks of class designation 3.5 Nos7771.057771.054.0FalseNoneNoneFalseNoneFalse31084.20
3486846124664NoneDSR It. No.10.1.9 Vol-5 Pg. No.113Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc.PVC pipes 160mm dai,kg/sqcm & class-3 Mtr648.9648.975.0FalseNoneNoneFalseNoneFalse48667.50
3486847124664NoneDSR It. No.13.34 Vol-2 Pg. No.123Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Ltr9.459.456000.0FalseNoneNoneFalseNoneFalse56700.00
3486848124664NoneDSR It. No.14.7A Vol-2 Pg. No.133Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer Nos4327.054327.056.0FalseNoneNoneFalseNoneFalse25962.30
3486849124664NoneDSR It. No.16.36 Vol-5 Pg. No.200Clearing and grubbing land including uprooting rank vegetable grass,b bushes, shrubs, saplings and trees upto 300mm girth by manual means, in areas of light jungle, removal of stumps, disposal of unserviceable materials, stacking of serviceable materials from road boundary etc. including cost of labour charges, all lead and lifts, etc. complete as directed by the Engineer in Charge. Sqm18.918.91380.0FalseNoneNoneFalseNoneFalse26082.00
3486850124664NoneDSR It. No.20.96 Vol-2 Pg. No.207Cleaning of office floors, toilet floors, corridors, lobbies, partitions, storage units, furnitures,electrical & electronic equipments, doors, windows, curtains, blinds etc., including cleaning of dust, etc., using suitable bombay broom stick, squezers Sqm3.153.153738.33FalseNoneNoneFalseNoneFalse11775.73950
17204502450000NoneNoneBuildingsElectrification Work7123242.6
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3486851124665NoneDSR It. No.1.1.1 Vol-6 Pg. No.2Open Conduit System,Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws 19/20 mm dia 2 mm thick Per Mtr72.4572.452017.0FalseNoneNoneFalseNoneFalse146131.650
3486852124665NoneDSR It. No.1.7.1 Vol-6 Pg. No.3Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. upto 50 mm conduit in brick wall Per Mtr30.4530.45150.0FalseNoneNoneFalseNoneFalse4567.50
3486853124665NoneDSR It. No.1.1.2 Vol-6 Pg. No.2Open Conduit System,Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws 25 mm dia 2 mm thick Per Mtr85.0585.05980.0FalseNoneNoneFalseNoneFalse83349.00
3486854124665NoneDSR It. No.1.10.1 Vol-6 Pg. No.3Supplying Galvanized steel flexible conduit pipe . mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy auge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely.20 mm diaPer Mtr55.6555.65100.0FalseNoneNoneFalseNoneFalse5565.00
3486855124665NoneDSR It. No.1.10.2 Vol-6 Pg. No.3Supplying Galvanized steel flexible conduit pipe . mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy auge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely.25 mm diaPer Mtr75.675.6300.0FalseNoneNoneFalseNoneFalse22680.00
3486856124665NoneDSR It. No.3.3.2 Vol-6 Pg. No.8Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for ounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.3 Way Each130.2130.214.0FalseNoneNoneFalseNoneFalse1822.80
3486857124665NoneDSR It. No.3.3.5 Vol-6 Pg. No.8Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for ounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.8 Way Each229.95229.9584.0FalseNoneNoneFalseNoneFalse19315.80
3486858124665NoneDSR It. No.3.3.6 Vol-6 Pg. No.8Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for ounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.10-12 Way Each274.05274.0547.0FalseNoneNoneFalseNoneFalse12880.350
3486859124665NoneDSR It. No.3.3.7 Vol-6 Pg. No.8Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for ounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.16 Way Each308.7308.726.0FalseNoneNoneFalseNoneFalse8026.20
3486860124665NoneDSR It. No.3.9 Vol-6 Pg. No.9Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N. F. screws. Sq CM0.370.3760000.0FalseNoneNoneFalseNoneFalse22200.00
3486861124665NoneDSR It. No.3.10.2 Vol-6 Pg. No.9Supplying 4 mm thick white plastic plate and covering for junction boxes of size . mm conduit using necessary machine screws.80mm Each15.7515.756.0FalseNoneNoneFalseNoneFalse94.50
3486862124665NoneDSR It. No.3.10.3 Vol-6 Pg. No.9Supplying 4 mm thick white plastic plate and covering for junction boxes of size . mm conduit using necessary machine screws.110 mm Each22.0522.05200.0FalseNoneNoneFalseNoneFalse4410.00
3486863124665NoneDSR It. No.2.1.1 Vol-6 Pg. No.5Point wiring using Copper wire with switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be erminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch Each299.25299.25165.0FalseNoneNoneFalseNoneFalse49376.250
3486864124665NoneDSR It. No.2.1.1 Vol-6 Pg. No.5Point wiring using Copper wire with switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be erminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switchEach299.25299.25217.0FalseNoneNoneFalseNoneFalse64937.250
3486865124665NoneDSR It. No.2.1.3 Vol-6 Pg. No.5Point wiring using Copper wire with switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be erminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch Each598.5598.5258.0FalseNoneNoneFalseNoneFalse154413.00
3486866124665NoneDSR It. No.3.6.7 Vol-6 Pg. No.5Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A Three Way socket. Each179.55179.55145.0FalseNoneNoneFalseNoneFalse26034.750
3486867124665NoneDSR It. No.12.47 Vol-6 Pg. No.52Supplying & Fixing of 230 V 20/40 W Fluorescent Lamp holder Supplying & Fixing of 70-150 W lamp holder 4 Pin Each155.4155.4654.0FalseNoneNoneFalseNoneFalse101631.60
3486868124665NoneDSR It. No.11.3.2 Vol-6 Pg. No.43Supplying of .feet -PVC Batten with integrated LED tube . W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4' - 20/22 WEach724.5724.5142.0FalseNoneNoneFalseNoneFalse102879.00
3486869124665NoneDSR It. No.11.6.5 Vol-6 Pg. No.45Supplying of recess mounting non integral type . LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 1'x4' 34-36WEach6192.96192.9120.0FalseNoneNoneFalseNoneFalse743148.00
3486870124665NoneDSR It. No.11.8.6 Vol-6 Pg. No.46Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/Lumileds/Osram make LED Source.LED Streetlight 150 WEach15440.2515440.2520.0FalseNoneNoneFalseNoneFalse308805.00
3486871124665NoneDSR It. No.6.5.2 Vol-6 Pg. No.30Supplying wall mounting fan suitable to operate at single- phase 230v AC. supply. 400 mm Sweep Each3372.63372.626.0FalseNoneNoneFalseNoneFalse87687.60
3486872124665NoneDSR It. No.13.7.1 Vol-6 Pg. No.56Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps On wall/ ceiling / Rafter / Girders Each128.1128.1317.0FalseNoneNoneFalseNoneFalse40607.70
3486873124665NoneDSR It. No.13.1.2 Vol-6 Pg. No.56Supplying and Fixing of.mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and ixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable apacity wires.Using 32mm dia G.I.Pipe Each1097.251097.2520.0FalseNoneNoneFalseNoneFalse21945.00
3486874124665NoneDSR It. No.6.3.2 Vol-6 Pg. No.30Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for peration on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.56" Sweep (1400 mm) Regular model Each3182.553182.55117.0FalseNoneNoneFalseNoneFalse372358.350
3486875124665NoneDSR It. No.13.10 Vol-6 Pg. No.57Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan egulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. Each179.55179.55117.0FalseNoneNoneFalseNoneFalse21007.350
3486876124665NoneDSR It. No.6.1 Vol-6 Pg. No.30Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply Each1566.61566.611.0FalseNoneNoneFalseNoneFalse17232.60
3486877124665NoneDSR It. No.13.13 Vol-6 Pg. No.57Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and olouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame Each742.35742.3511.0FalseNoneNoneFalseNoneFalse8165.850
3486878124665NoneDSR It. No.2.3.1 Vol-6 Pg. No.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.sqmm Mtr19.9519.954600.0FalseNoneNoneFalseNoneFalse91770.00
3486879124665NoneDSR It. No.2.3.2 Vol-6 Pg. No.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 sqmm Mtr27.327.32450.0FalseNoneNoneFalseNoneFalse66885.00
3486880124665NoneDSR It. No.2.3.3 Vol-6 Pg. No.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mm2 Mtr44.144.14600.0FalseNoneNoneFalseNoneFalse202860.00
3486881124665NoneDSR It. No.2.3.4 Vol-6 Pg. No.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 mm2 Mtr66.1566.152069.0FalseNoneNoneFalseNoneFalse136864.350
3486882124665NoneDSR It. No.3.6.1 Vol-6 Pg. No.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch Each107.1107.1785.0FalseNoneNoneFalseNoneFalse84073.50
3486883124665NoneDSR It. No.3.6.10 Vol-6 Pg. No.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal Socket Each247.8247.847.0FalseNoneNoneFalseNoneFalse11646.60
3486884124665NoneDSR It. No.3.14.5 Vol-6 Pg. No.10Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board.6A Bakelite Ceiling Rose No81.981.9131.0FalseNoneNoneFalseNoneFalse10728.90
3486885124665NoneDSR It. No.3.6.4 Vol-6 Pg. No.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module No374.85374.85131.0FalseNoneNoneFalseNoneFalse49105.350
3486886124665NoneDSR It. No.5.18.8 Vol-6 Pg. No.17Supplying & fixing miniature circuit breaker sonexisting MCB distribution board susingnecessary fixing material sand'C'Type curve,indicator ON/OFF,energy cross 3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC60898.40 A TPN Each3196.23196.2131.0FalseNoneNoneFalseNoneFalse418702.20
3486887124665NoneDSR It. No.5.18.1 Vol-6 Pg. No.17Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SP Each435.75435.75100.0FalseNoneNoneFalseNoneFalse43575.00
3486888124665NoneDSR It. No.5.18.4 Vol-6 Pg. No.17Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A DP Each775.95775.9538.0FalseNoneNoneFalseNoneFalse29486.10
3486889124665NoneDSR It. No.5.7.5 Vol-6 Pg. No.14Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.200 A Each1500.451500.453.0FalseNoneNoneFalseNoneFalse4501.350
3486890124665NoneDSR It. No.541.2 Vol-6 Pg. No.20Supplying and fixing angle iron frame work fabricated out of M.S.angle iron.and M.S.Flat.with bolts, washer setc.,and painted with 2 coats of red oxide and then two coats of approved paint.50 x 50 x 6 mm Mtr414.75414.758.0FalseNoneNoneFalseNoneFalse3318.00
3486891124665NoneDSR It. No.5.38 Vol-6 Pg. No.19Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. Each540.75540.753.0FalseNoneNoneFalseNoneFalse1622.250
3486892124665NoneDSR It. No.32.14 Vol-6 Pg. No.131.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 95 Sqmm, 3.5 Core, (21 GI Strips - 4 x 0.8 mm) Km391875.75391875.750.2FalseNoneNoneFalseNoneFalse78375.150
3486893124665NoneDSR It. No.3.6.9 Vol-6 Pg. No.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.32A DP Switch Each342.3342.329.0FalseNoneNoneFalseNoneFalse9926.70
3486894124665NoneDSR It. No.5.21 Vol-6 Pg. No.18Supplying, fixing and wiring earth leakage relay with corebalanced current transformer suitable for single phase 50HzAC with latest micro controller based, digital read out of percentage leakage current, programmable delay/auto/manual resetfacility suitable to mounton DIN rail/ flush mounting on panel board. Each9717.759717.751.0FalseNoneNoneFalseNoneFalse9717.750
3486895124665NoneDSR It. No.5.18.9 Vol-6 Pg. No.18Supplying & fixing miniature circuit breaker sonexisting MCB distribution board susingnecessary fixing material sand'C'Type curve, indicator ON/OFF,energycross- with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC60898. 50-63 A TPN Each3242.43242.410.0FalseNoneNoneFalseNoneFalse32424.00
3486896124665NoneDSR It. No.5.14.10 Vol-6 Pg. No.16Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947 200 A Each41073.941073.91.0FalseNoneNoneFalseNoneFalse41073.90
3486897124665NoneDSR It. No.5.12.4 Vol-6 Pg. No.15Supplying of on load change over switches 4poles,AC-23A Duty,415V,50Hz,AC Supply.With all accessories.(SM Enclosure Sheet Metal Execution) 200 A Each16011.4516011.451.0FalseNoneNoneFalseNoneFalse16011.450
3486898124665NoneDSR It. No.5.40.2 Vol-6 Pg. No.20Supplying.Arated 3phase with neutral busbarusing required capacity electrolyticaluminium strips covered with heat shrinkable coloured PVC sleeve,mounted on phenolic/FRP/DMC insulator which are mounted onpowder coated 40x6mm M.S.flat framework in existing panel board. The busbarshall have suitable holes for termination ofincomingandoutgoingcablesasperISspecification with necessary bolts, nuts and washers etc., complete 250 A 4 x 30 x 10 mm Aluminium Strips Rmtr3606.753606.756.0FalseNoneNoneFalseNoneFalse21640.50
3486899124665NoneDSR It. No.5.23 Vol-6 Pg. No.18Supplying,fixingandwiring0to30VDirectReadingDCVoltmeter/Ammeter. Each724.5724.51.0FalseNoneNoneFalseNoneFalse724.50
3486900124665NoneDSR It. No.5.36 Vol-6 Pg. No.19Supplying, fixing and wiring 1000/5A to1600/5A 15VA Burdenclass 1 Current Transformer Each882.0882.04.0FalseNoneNoneFalseNoneFalse3528.00
3486901124665NoneDSR It. No.5.42.2 Vol-6 Pg. No.20Fabricating supplying and mounting MS box made out.SWG suitable for floor/wall mounting, fully weather proof with provision for better heat dissipation,provided withhinged front cover,equipped with tamperprooflocking arrangements,with suitable size clamps with necessary cable entry pipe with glandand box should be finished with 7tanks treatment with powdercoated paintand finally finished with approved colour etc., complete.16 SWG Sq CM0.450.45150000.0FalseNoneNoneFalseNoneFalse67500.00
3486902124665NoneDSR It. No.5.35 Vol-6 Pg. No.19Supplying, fixing and wiring ElectronicTrivector Meter (ETV) 5to32/63 A three phase 4 wire whole current class-1Accuracy Energy Meter. Each5990.255990.251.0FalseNoneNoneFalseNoneFalse5990.250
3486903124665NoneDSR It. No.5.20.10 Vol-6 Pg. No.18Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 63 A 4 pole Each5822.255822.251.0FalseNoneNoneFalseNoneFalse5822.250
3486904124665NoneDSR It. No.5.13.4 Vol-6 Pg. No.16Supply and fixing of 3 pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts,nuts,washer sand wiring etc., complete with AC-3 Rating and as per IS-13947. 100 A Each9476.259476.255.0FalseNoneNoneFalseNoneFalse47381.250
3486905124665NoneDSR It. No.12.58.4 Vol-6 Pg. No.54GI/Copper strips for grounding connections,using necessary fixing materials as required.40 x 6 mm GI strip Mtr190.05190.0518.0FalseNoneNoneFalseNoneFalse3420.90
3486906124665NoneDSR It. No.3.5.1 Vol-6 Pg. No.8Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting backplate with required nos.of machine screws,bolts nuts etc.,complete on the existing metal/PVC box. 1 to 2 Module Each143.85143.8556.0FalseNoneNoneFalseNoneFalse8055.60
3486907124665NoneDSR It. No.3.5.5 Vol-6 Pg. No.8Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting backplate with required nos.of machine screws,bolts nuts etc.,complete on the existing metal/PVC box. 8 Module Each298.2298.284.0FalseNoneNoneFalseNoneFalse25048.80
3486908124665NoneDSR It. No.3.5.6 Vol-6 Pg. No.8Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting backplate with required nos.of machine screws,bolts nuts etc.,complete on the existing metal/PVC box. 10-12 Module Each361.2361.247.0FalseNoneNoneFalseNoneFalse16976.40
3486909124665NoneDSR It. No.3.5.7 Vol-6 Pg. No.8Supplying and fixing superior quality modulars witch mounting polycarbonate plate with necessary supporting back plate with required nos.of machine screws,bolts nuts etc.,complete on the existing metal/PVC box. 16 Module Each416.85416.8528.0FalseNoneNoneFalseNoneFalse11671.80
3486910124665NoneDSR It. No.12.57 Vol-6 Pg. No.54Supplying fixing and wiring earth electrode for grounding of lifts,transformers,DGsets etc.using 40 mm dia2.9 mm thick 2.5 m long GI pipe with GI funnel with mesh and suitablesize reducer fixed on the top of the earth electrode.The funnel should been closed in a CC chamber of 400x400x400mm with a cast iron cover.Theearthelectrode shall have staggered holes of 12mm dia and theelectrode should be covered 150 mm allround with alternate layers of saltandcharcoal from the bottom of the CC chamber.The connection from the electrode is to be established through GI strip using GI bolts and nuts. No4468.84468.84.0FalseNoneNoneFalseNoneFalse17875.20
3486911124665NoneDSR It. No.6.8.6 Vol-6 Pg. No.31Supplying of.TR Invertor type split Airconditioners suitable for operation on A/C supply single phase 50Hz230V with hermeticallysealedinverter compressor with air cooled condenser,latest R410A/R-32 refrigerant fan motor,start & run capacitors,relay & over load protectorinternalunit,with one in door & one out door unit The condenserunit will be placed out side the room avoid noise in cluding standard length of suitable size copper tubing covered with nitrilerubberinsulationtube.suitable capacity 3coresheathed/PVC copper cable and a battery operated wireless remote unit. 5 star 2 Ton capacity Each70768.9570768.9530.0FalseNoneNoneFalseNoneFalse2123068.50
3486912124665NoneDSR It. No.6.12 Vol-6 Pg. No.32Installation charges for splitty pe air conditioner with allied works for one indoor and one outdoor unitis to be mounted onsuitableAngleIron support upto 3.0 Ton split/cassette type A/C. Each3333.753333.7530.0FalseNoneNoneFalseNoneFalse100012.50
3486913124665NoneDSR It. No.9.1.3 Vol-6 Pg. No.38Supplying, erecting, testing and commissioning of voltage stabilizer suitable for170to270 vinputand load variation from no load to full load,with over load protection,spike suppression,operatingat 00Cto 400 C. Range etc., complete. 5kVA Capacity Each10149.310149.330.0FalseNoneNoneFalseNoneFalse304479.00
3486914124665NoneDSR It. No.6.22 Vol-6 Pg. No.32Extra for Fabrication supply and fixing of Stand fabricated usings lot tedangle/Langle of size 6mmx50mm form ounting outdoor /indoor A.C. unit/ Batteries. Each5047.355047.3530.0FalseNoneNoneFalseNoneFalse151420.50
3486915124665NoneDSR It. No.5.19.4 Vol-6 Pg. No.18Supplying and fixing regular MCB distribution boards on wall/oodboard/flush mounting using required clamps,bolts,nutsetc.,with provision for fixing suitable type capacity MCB's single phase/3phase/single door with powder coated painting Made out of 14 SWGMS enclosure. 12 Way SP & N Each1956.151956.154.0FalseNoneNoneFalseNoneFalse7824.60
3486916124665NoneDSR It. No.5.18.4 Vol-6 Pg. No.17Supplying & fixing miniature circuit breaker son existing MCB distribution boards using necessary fixing material sand'C'Type curve,indicator ON/OFF,energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC60898.6-32 A DP Each775.95775.9530.0FalseNoneNoneFalseNoneFalse23278.50
3486917124665NoneDSR It. No.5.18.6 Vol-6 Pg. No.17Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing material sand'C'Type curve,indicator ON/OFF,energy cross-3with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC60898.50-63 A DP Each1157.11157.14.0FalseNoneNoneFalseNoneFalse4628.40
3486918124665NoneDSR It. No.1.1.4 Vol-6 Pg. No.2Supplying heavy gauge PVC conduit pipe.dia.mm thick confirming to IS2509 with suitable size bends,junction boxes,adhesive pasteetc,and fixing using inverted wood plugs in case of RCC ceiling and RCCwall/stone structure or rawl plugs in case of brick walls and cement plaster in g the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 40 mm dia 2.5 mm thick Mtr156.45156.45430.0FalseNoneNoneFalseNoneFalse67273.50
3486919124665NoneDSR It. No.32.03 Vol-6 Pg. No.131.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm) Km123904.2123904.22.5FalseNoneNoneFalseNoneFalse309760.50
3486920124665NoneDSR It. No.5.41.1 Vol-6 Pg. No.20Supplying and fixing angle iron frame work fabricated out of M.S. angle iron .and M.S. Flat.with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint.40 x 40 x 6 mm Each320.25320.256.0FalseNoneNoneFalseNoneFalse1921.50
17204502450000NoneNoneBuildingsDG Set1164440.55
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3486921124666NoneDSR It. No.55.2 Vol-6 Pg. No.75DG Set : 50 kW/62.5 kVA Diesel Generator set rated at 50 kW/62.5 kVA, 415 V, 0.8 pf mounted on a base frame, complete with inbuilt fuel tank and battery 1 no. 12 V & inbuilt standard manual Control Panel with acoustic enclosure : NAL Approved D.G. Set 62.5 kVA capacity with AMF panel as per technical specificationNo1145124.751145124.751.0FalseNoneNoneFalseNoneFalse1145124.750
3486922124666NoneDSR It. No.12.57 Vol-6 Pg. No.54Supplying fixing and wiring earth electrode for grounding of lifts,trans formers,DG sets etc.using 40mm dia 2.9mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the to p of the earth electrode.The funnel should been close dina CC chamber of 400x400x400mm with a cast iron cover.The earth electrode shall have stagge red holes of 12 mm dia and the electrode should be covered 150mm all-round with alternate layers of saltandcharcoalfromthebottomoftheCCchamber.Theconnectionfromtheelectrode is to be established through GI strip using GI bolts and nuts. No4468.84468.81.0FalseNoneNoneFalseNoneFalse4468.80
3486923124666NoneDSR It. No.12.58.2 Vol-6 Pg. No.54GI/Copper strips for grounding connections, using necessary fixing materials as required.25 x 3 mm GI strip Mtr86.186.140.0FalseNoneNoneFalseNoneFalse3444.00
3486924124666NoneDSR It. No.12.58.4 Vol-6 Pg. No.54GI/Copper strips for grounding connections, using necessary fixing materials as required. 40 x 6 mm GI strip Mtr190.05190.0560.0FalseNoneNoneFalseNoneFalse11403.00
17204502450000NoneNoneBuildingsSound System1150225.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3486925124667NoneMarket RateSound System Fire 57 - 2-Way, 1300W RMS Dual Speaker with 2x1.5"LF & HF,Max SPL 133dB, 8 ohms No69000.069000.02.0FalseNoneNoneFalseNoneFalse138000.00
3486926124667NoneMarket RateStudiomaster Professional Power amplifier PA 4.5 1600 WATTS AT 4 OHMS STEREO AMPNo65000.065000.01.0FalseNoneNoneFalseNoneFalse65000.00
3486927124667NoneMarket RateS 8028 - 2x18", 3000W RMS Dual SUBWOOFER with RCF drivers Max SPL 134dB, 8 ohms No110000.0110000.02.0FalseNoneNoneFalseNoneFalse220000.00
3486928124667NoneMarket RateStudiomaster Professional Power amplifier PA 10.0 3100 WATTS AT 4 OHMS STEREO AMP No89000.089000.01.0FalseNoneNoneFalseNoneFalse89000.00
3486929124667NoneMarket RateClio 156 Studiomaster Stage moniters 1000 watts Active and distribution speaker No33000.033000.06.0FalseNoneNoneFalseNoneFalse198000.00
3486930124667NoneMarket RateXLR to XLR mic cable 10 mtrs No2125.02125.08.0FalseNoneNoneFalseNoneFalse17000.00
3486931124667NoneMarket RateJack to Jack instrument cable 10 mtrs No1200.01200.04.0FalseNoneNoneFalseNoneFalse4800.00
3486932124667NoneMarket RateSm 650 Xlr Studiomaster Dynamic super cordoid vocal mic No5400.05400.05.0FalseNoneNoneFalseNoneFalse27000.00
3486933124667NoneMarket RateBMS 101 Boom Mic Stand No1605.01605.05.0FalseNoneNoneFalseNoneFalse8025.00
3486934124667NoneMarket RateAWB 30 Wall speaker Stand No2100.02100.04.0FalseNoneNoneFalseNoneFalse8400.00
3486935124667NoneMarket RateProcessor for top and subwoofer No34000.034000.01.0FalseNoneNoneFalseNoneFalse34000.00
3486936124667NoneMarket RateXR 100 4H Studiomaster 4 handheld, UHF wireless mic No24000.024000.01.0FalseNoneNoneFalseNoneFalse24000.00
3486937124667NoneMarket RateORB 2442 Stuidomaster Channel mixer 24 Mic /28 lines input Channel Mixer with Dual digital efx USB and blue tooth media player with recording and soundcard inbuilt No66000.066000.01.0FalseNoneNoneFalseNoneFalse66000.00
3486938124667NoneMarket RateSVC 15000 Stuidomaster 15kva Servo stabilizer No44000.044000.01.0FalseNoneNoneFalseNoneFalse44000.00
3486939124667NoneMarket RateSnake cable 24 channel 40 mtrs with connectors & stage box No43000.043000.01.0FalseNoneNoneFalseNoneFalse43000.00
3486940124667NoneMarket RateSpeaker cable 2.5 sq mm 80/2 ATC round 14awg (100 mts) Coil14000.014000.03.0FalseNoneNoneFalseNoneFalse42000.00
3486941124667NoneMarket Rate19 pre wired 16u rack with weels, fans, sockets & doorsNo22000.022000.01.0FalseNoneNoneFalseNoneFalse22000.00
3486942124667NoneMarket RateInstallation Testing and commissioning Job100000.0100000.01.0FalseNoneNoneFalseNoneFalse100000.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17204502480000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17204502480000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17204502480001NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of e-Procurement portal due to internet connectivity issues and technical glitches at bidders endNone
17204502480000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17204502480000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17205051300000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidder.None
17205051450000NoneNoneELIGIBILITYAs per Karnataka State Government order No.LD/300/LET/2006 Bangalore Dated 01.01.2007 and Government Letter No.PW/134/BMS/2007 Dated 27.7.2007, a sum amounting to 1%of the bill amount will be deducted towards Construction Labour Welfare fund.None
17205051600000NoneNoneELIGIBILITYThe Item Rate quoted shall include the Royalty Charges on construction materials and other taxes as per prevailing Government Orders.None
17205051770000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17205051900000NoneNoneELIGIBILITYThe Tenderer shall obtain the workdone certificate in the prescribed format from the Competent Authority not below the rank of Executive Engineer (District Level Officer) and scan the Original Certificate and attach the scanned file to the Bid. The Original Certificate/Certificates shall be produced at the time of opening of technical Bids for physical verification.None
17205052060000NoneNoneELIGIBILITYFinancial Year will be reckoned as the period between first day of April and Thirty first day of March of succeeding year(both days inclusive).None
17205052210000NoneNoneELIGIBILITYThe Tenderer shall scan the Original Ownership Documents/ Lease/ Hire commitment Agreement for the Machinery and attach the scanned file to the Bid. The Original Documents shall be produced at the time of opening of technical Bids for physical verification.None
17205052390000NoneNoneELIGIBILITYThe tenderer shall note that the scanned Documents can also be uploaded in the tasks created under Document/Evidence Required from the BidderNone
17205052510000NoneNoneELIGIBILITYThe Employer reserves the right to Reject any or all Tenders without assigning any reason.None
17205052650000NoneNoneELIGIBILITYThe defect liability period for this work is 365 daysNone
17205052820000NoneNoneELIGIBILITYThe Department is not responsible for any delay in accessing kppp portal.None
17205052940000NoneNoneELIGIBILITYThe rates of all the items appeared in Bill of Quantities are inclusive of all leads and liftsNone
17205053110000NoneNoneELIGIBILITYThe contractor shall bound to comply the prevailing rules and regulations with regard to the EPF rules and any modifications before and after execution of agreementNone
17205053250000NoneNoneELIGIBILITYAfter the award of the contract, the contractor has to furnish the details in respect of labour employed and the EPF details for this work in every RA bill.None
17205053380000NoneNoneELIGIBILITYBidders are advised to note that , 18% GST will be added to the contract amount.None
17205053610000NoneNoneELIGIBILITYFinancial turnover of previous years shall be given a weight of 10% per year to bring them to the price level of the 2024-25 in the Technical Qualification Criteria mentioned in the next section.None
17205053740000NoneNoneELIGIBILITYThe bidder should mention the UDIN No on the turnover certificate, failing which bid is rejected.None
17205053940000NoneNoneELIGIBILITYIf the bidder uploaded the false document while participating in the tender, the bidder will be responsible and action will be initiated as per the tender clause.None
17205054080000NoneNoneELIGIBILITYThe work should be completed in 11 (Eleven) Months ( including monsoon)None
17207853260000NoneNoneELIGIBILITYEMD of Rs 7,60,000.00 is to be paid in full through e payment Rs. 1,00,000/-on e payment and Rs. 6,60,000/- shall be in favour of the Executive Engineer, PWD Division, Kalaburagi and may be in the form of Bankers Cheque/Demand Draft/ Pay Order in favour of Executive Engineer, PWD Division, Kalaburagi payable at Kalaburagi pledges to the Executive Engineer, PWD Division, Kalaburagi, or Bank Guarantee in the prescribed format obtained from any nationalised / Scheduled BankNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneTo qualify for award of this contract, each Tenderer in his name should have in the last five years i.e., 2019-20, 2020-21, 2021-22, 2022-23 & 2023-24 & a)Achieved in at least two financial years a minimum financial turnover (in all classes of civil engineering construction works only) of Rs. 1008.45 LakhsPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneTo qualify for award of this contract, each Tenderer in his name should have in the last five years i.e., 2019-20, 2020-21, 2021-22, 2022-23 & 2023-24 b) Satisfactorily completed, as prime contractor, at least one similar work such as Building Work of value not less than Rs. 252.11 LakhsPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneTo qualify for award of this contract, each Tenderer in his name should have in the last five years i.e., 2019-20, 2020-21, 2021-22, 2022-23 & 2023-24 c) Executed in any one year, the following minimum quantities of work: 1)Earthwork in both excavation and filling (Combined quantities):512.46Cum (2)PCC/RCC:86.09Cum (3)BBM: 128.58 Sqm (4)Steel:0.34Tonne (5)Plastering:1048.34Sqm (6)PAINTING: 12430.41Sqm (7)Flooring:765.51Sqm (8)MSGrill:2428.17kgs (9)Falseceiling:1394.43Sqm (10)Waterproofing:520.03Sqm (11)SSRailing:124Kgs (12)BM/SDBC:40.26Cum (13)GSB:40.26Cum (14)WMM:410.28Cum (15)Seating Supplying & Installing amest cladding layered fabric Floor mounted seat:640 NosPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneMaximum of Civil Engineering works executed in any one year during the last five years (updated to 2024-25 price level) taking into account the completed as well as works in progress. (Financial turn over of previous years shall be given a weight of 10% per year to bring them to the price level of the 2024-25)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Statement on the Letter Head of the Tenderer
NoneNoneNoneNoneTotal value of civil engineering construction works executed and payments received in the last five years 2019-20, 2020-21, 2021-22, 2022-23 & 2023-24Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneQualification and experience of the key technical and Management personnel in permanent employment with the Tenderer and those that are proposed to be deployed on this work, if work is awarded.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Biodata of the personnel
NoneNoneNoneNoneEach Tenderer should further demonstrate: Availability by owning Lease/Hire/basis the following key and critical equipment for this work For Lease/Hire basis relevant documents commitment agreements etc shall be scanned and uploaded- 1)Concrete Batch Mix Plant/ Rotavator of suitable specification 1 No lease/Hire, 2) Transit Mixer 1 No own 1 no lease, 3) Tipper 1 No own 1 no lease, 4) Shuttering Materials 500sqm own 500sqm lease 5) Excavator viz JCB / Hitachi 1 No own 1 no lease, 6) Pin/Plate vibrators Pin/Plate vibrators 2 No own 2 no lease 7) Water Tanker 1 No own 1 no leaseCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Information in Format-8 and scanned copies of the owership Documents & Hire commitment Agreements
NoneNoneNoneNoneLiquid Assets and /or availability of credit facilities of no less than Rs. 137.52 lakhs (Credit Lines/letter of credit/ certificates from the banks for meeting the fund requirement etcFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneReport on the financial standing of the Tenderer, such as profit and loss statements and auditors report for the last five years.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneITR Filed Copy (Mentioning PAN)
NoneNoneNoneNoneLatest Income Tax Clearance CertificateFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneITR Filed Copy (Mentioning PAN)
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)OthersConstitutional or Legal Status of the Tenderer
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneInformation in Format-6 and Letter of AcceptanceOthersInformation of the works for which Tender acceptance letters are received.
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Information in Format-6 and Letter of Acceptance
NoneNoneNoneNoneInformation in Format-7OthersInformation of the works for which Tenderer has submitted Tender.
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Information in Format-7
NoneNoneNoneNoneThe proposed methodology and program of construction, backed with equipment planning and deployment, duly supported with broad calculations and quality control procedures proposed to be adopted, justifying their capability of execution and completion of the work as per technical specifications within the stipulated period of completion.OthersCPM/PERT Chart
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- CPM/PERT Chart
NoneNoneNoneNoneValue at 2024-25 price level, of existing commitments and on-going works to be executed during the next 11 months(Financial commitment of previous years shall be given a weight of 10% per year to bring them to the price level of the 2024-25), (Monthwise commitment shall be furnished).OthersExisting commitments and on-going works
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Statement on the Letter head of the tenderer
NoneNoneNoneNoneAssessed Tender Capacity shall be more than the Tendered AmountOthersAssessed Tender Capacity shall be more than the Tendered Amount
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Assessement on the Letter Head of the Tenderer
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover Certificate having UDINTrueTechnical Bid
PWD Contractor Registration certificateTrueTechnical Bid
Similar Nature of work doneTrueTechnical Bid
Line of creditTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1720786196000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of the Executive Engineer, PWD Bhavan, Old Jewargi Road
streetNone
cityKalaburagi
stateKarnataka
pin585102
tenderRecallDTONone