createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1720692734817
version6
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee2500.00
emd169300.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose24-07-2024 17:00:00
tenderQueryClose18-07-2024 17:00:00
technicalBidOpen26-07-2024 11:00:00
publishedDate15-07-2024 22:11:38
publishedByPostCMC_MCOM_HSK
publishedByUserKPE13600 - ZAHEER ABBAS S
bidValidityPeriod90
noOfCalls2
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnTrue
percentageRateTypeTextNone
contactPersonAEE ENVIROMENT ENGINEER
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08027931221
mobileNumber9035713489
tenderSupplierListNone
tenderSchedule
createdTs1720692734819
version11
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/BD/WORK_INDENT18793/CALL-2
titleCONSTRUCTION OF MATERIAL RECOVERY FACILITY AT SWM SITE HOSAKOTE
descriptionCONSTRUCTION OF MATERIAL RECOVERY FACILITY AT SWM SITE HOSAKOTE
categoryWORKS
categoryTextWorks
ecv9990000.00
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2263
locationNameDMA City Municipal Council Hosakote
provisionalAmount9990000.0
groupOverheadTotal1525507.45
fileNumberHSKCMC/SWM/MRF/001/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17206927350000NoneNoneBuildingsCONSTRUCTION OF MATERIAL RECOVERY FACILITY AT SWM SITE HOSAKOTE8464492.55
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3508747125636NoneMRF01Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. (Item No. 1.14.1 Page No. 8 Vol.1 PWD SR)Cum105.06105.0692.0FalseNoneNoneFalseNoneFalse9665.520
3508748125636NoneMRF02Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement & formwork shall be paid separately. Specification No. KBS 2.1, (Item No. 2.1.2 Page No. 15 Vol.1 PWD SR)Cum5833.925833.9290.01FalseNoneNoneFalseNoneFalse525111.13920
3508749125636NoneMRF03AProviding and laying in position cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes ,labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115) Footing, hall grade slab, Ramp-1 Cum7192.87192.8130.37FalseNoneNoneFalseNoneFalse937725.3360
3508750125636NoneMRF03BProviding and laying in position cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes ,labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115) Column baseCum11210.411210.49.21FalseNoneNoneFalseNoneFalse103247.7840
3508751125636NoneMRF04Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No. 2.2.3 Page No. 15 Vol.1 PWD SR & Appendix I page No.115)Cum9694.089694.0810.71FalseNoneNoneFalseNoneFalse103823.59680
3508752125636NoneMRF05Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification .(Item No. 2.11 Page No. 18 Vol.1 PWD SR)Kg92140.7192140.718.7568FalseNoneNoneFalseNoneFalse806857.7693280
3508753125636NoneMRF06Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) . (Item No. 5.4 Page No. 9 Vol.2 PWD SR)Cum6580.676580.6741.7939FalseNoneNoneFalseNoneFalse275031.8639130
3508754125636NoneMRF07Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,allmaterials,usage& all other appurtenaces required to complete the work (Item No. 1.8 Page No. 7 Vol.1 PWD SR)Cum488.22488.22523.121FalseNoneNoneFalseNoneFalse255398.134620
3508755125636NoneMRF08Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Item No. 6.33 Page No. 17 Vol.2 PWD SR)Sqm1267.931267.93274.416FalseNoneNoneFalseNoneFalse347940.278880
3508756125636NoneMRF09Providing 15mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.2.1, Page No. 41, Vol.2)Sqm303.85303.85597.2052FalseNoneNoneFalseNoneFalse181460.800020
3508757125636NoneMRF10Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. (Item No. 11.2, Page No. 77, Vol.2)Kg116.39116.3927260.0FalseNoneNoneFalseNoneFalse3172791.40
3508758125636NoneMRF11Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Item No. 7.38, Page No. 26, Vol.2)Sqm585.04585.041623.508FalseNoneNoneFalseNoneFalse949817.120320
3508759125636NoneMRF12Finishing with Deluxe Multi surface paint system for interiors and exteriors using pirmer as per manufactures specifications: Two coats applied on walls @1.25L/10sqm over and including one coat of special primer applied @0.75L/10sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge (The gloss should be 50% @ 60 degree angle with 10 years life) (I.no:8.33.1, Pg.no:46, Vol-2)Sqm162.74162.74599.37FalseNoneNoneFalseNoneFalse97541.47380
3508760125636NoneMRF13Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Item No. 11.6.1, Page No. 76, Vol.2)Sqm2711.992711.9933.75FalseNoneNoneFalseNoneFalse91529.66250
3508761125636NoneMRF14Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Item No. 11.8.4, Page No. 79, Vol.2)No25426.5825426.582.0FalseNoneNoneFalseNoneFalse50853.160
3508762125636NoneMRF15Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications.(Item No. 11.35.1.1, Page No. 87, Vol.2)Kg465.56465.56480.0FalseNoneNoneFalseNoneFalse223468.80
3508763125636NoneMRF16Painting steel work with Deluxe Multi surface paint to give an even shade. Two cot applied @ 0.9L/10sqm over an under coat of primer applie @0.80L/10sqm of approved brand and manufacture including preparing the surface after throughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge (I.N0:8.33.3, Pg.no:47, Vol-2)Sqm143.17143.1774.25FalseNoneNoneFalseNoneFalse10630.37250
3508764125636NoneMRF17ASupplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Overload and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947-2. (Icu=100%lcs).In 4P MCCB,all Poles should have protection for Short-Cicrcuit/OverLoad.For Microprocessor MCCB S Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open).Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. (P.No.17, I.No.5.15.1 in CSR Electrical SR Volume-6 2023-24) Three Pole- 100 A 25 kA (P.No.17, I.No.5.15.1 in CSR Electrical SR Volume-6 2023-24)Each6268.586268.583.0FalseNoneNoneFalseNoneFalse18805.740
3508765125636NoneMRF17BFour Pole-100 A 25 kA (P.No.17, I.No.5.15.9 in CSR Electrical SR Volume-6 2023-24)No8741.618741.611.0FalseNoneNoneFalseNoneFalse8741.610
3508766125636NoneMRF18ASupplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA.(P.No.21, I.No.5.46.1 & 5.46.6 in CSR Electrical SR Volume-6 2023-24) 16-32 A SP (P.No.21, I.No.5.46.1 in CSR Electrical SR Volume-6 2023-24)Each216.3216.36.0FalseNoneNoneFalseNoneFalse1297.80
3508767125636NoneMRF18B63 A TP (P.No.21, I.No. 5.46.6 in CSR Electrical SR Volume-6 2023-24)Each1230.851230.858.0FalseNoneNoneFalseNoneFalse9846.80
3508768125636NoneMRF19Supplying.A rated 3 phase with neutral busbar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve,mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board.The busbar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.(P.No.20, I.No.5.40.1 in CSR Electrical SR Volume-6 2023-24)Mtr2538.952538.9510.0FalseNoneNoneFalseNoneFalse25389.50
3508769125636NoneMRF20SupplyingandfixingangleironframeworkfabricatedoutofM.S.angleiron.andM.S.Flat.withbolts,washersetc.,andpaintedwith 2 coats of red oxide and then two coats of approved paint.(P.No.20, I.No.5.41.1 in CSR Electrical SR Volume-6 2023-24)Mtr314.15314.156.0FalseNoneNoneFalseNoneFalse1884.90
3508770125636NoneMRF21Fabricating supplying and mounting MS box made out.SWG suitable for floor/wall mounting,fully weather proof with provision for better heat dissipation,provided with hinged front cover,equipped with tamper proof locking arrangements,with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7 tanks treatment with powder coated paint and finally finished with approved colour etc., complete.(P.No.20, I.No.5.42.1 in CSR Electrical SR Volume-6 2023-24)Sq CM0.510.5135000.0FalseNoneNoneFalseNoneFalse17850.00
3508771125636NoneMRF22Supply and fixing of 3pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts,nuts,washers and wiring etc., complete with AC-3 Rating and as per IS-13947.(P.No.20, I.No.5.13.1 in CSR Electrical SR Volume-6 2023-24)Each1328.71328.79.0FalseNoneNoneFalseNoneFalse11958.30
3508772125636NoneMRF23Supplying and fixing Micro processor Based Astro nomical timer Switch with using necessary bolts, nuts and washers.(P.No.21, I.No.5.48 in CSR Electrical SR Volume-6 2023-24)Each4988.294988.293.0FalseNoneNoneFalseNoneFalse14964.870
3508773125636NoneMRF24Supply and fixing of Auxiliary contactor relay with 2 NO and 2 NC contact and operating coil voltage of 220V to 260V. fixed on existing wood/panel board using necessary bolts, nuts, washers and wiring etc.,(P.No.22, I.No.5.53 in CSR Electrical SR Volume-6 2023-24)Each1369.91369.93.0FalseNoneNoneFalseNoneFalse4109.70
3508774125636NoneMRF25ASupplying and fixing of metal clad industrial plugs and sockets. (P.No.22, I.No.5.53 in CSR Electrical SR Volume-6 2023-24) 16 Amps (P.No.9, I.No.3.13.3 in CSR Electrical SR Volume-6 2023-24)Each465.69465.692.0FalseNoneNoneFalseNoneFalse931.380
3508775125636NoneMRF25B32 Amps (P.No.9, I.No.3.13.4 in CSR Electrical SR Volume-6 2023-24)Each628.16628.162.0FalseNoneNoneFalseNoneFalse1256.320
3508776125636NoneMRF26Supplying, fixing and wiring 0to30 A Direct Reading AC analog type Ammeter.(P.No.18, I.No.5.24 in CSR Electrical SR Volume-6 2023-24)Each478.95478.954.0FalseNoneNoneFalseNoneFalse1915.80
3508777125636NoneMRF27Supplying,fixing and wiring 0 to 600 V 96x96mm AC Voltmeter on existing panel/wood board.(P.No.18, I.No.5.22 in CSR Electrical SR Volume-6 2023-24)Each465.56465.561.0FalseNoneNoneFalseNoneFalse465.560
3508778125636NoneMRF28Supplying, fixing and wiring rotary selector switch suitable for Ammeter.(P.No.19, I.No.5.27 in CSR Electrical SR Volume-6 2023-24)Each206.0206.04.0FalseNoneNoneFalseNoneFalse824.00
3508779125636NoneMRF29Supplying, fixing and wiring rotary selector switch suitable for Voltmeter.(P.No.19, I.No.5.28 in CSR Electrical SR Volume-6 2023-24)Each164.8164.81.0FalseNoneNoneFalseNoneFalse164.80
3508780125636NoneMRF30Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound.(P.No.19, I.No.5.34 in CSR Electrical SR Volume-6 2023-24)Each578.86578.864.0FalseNoneNoneFalseNoneFalse2315.440
3508781125636NoneMRF31Supplying and fixing digital frequency meter with latest micro controller technology,ultra bright 4digit LED display,from 30-500VAC and optional or relay output for high/low frequency and wiringcomplete.(P.No.19, I.No.5.32 in CSR Electrical SR Volume-6 2023-24) Each1004.251004.251.0FalseNoneNoneFalseNoneFalse1004.250
3508782125636NoneMRF32Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS2834.3 phase,400/440V grade,for power factor improvement of rotating machineries like induction motor.(P.No.19, I.No.5.37 in CSR Electrical SR Volume-6 2023-24)Kvar494.4494.45.0FalseNoneNoneFalseNoneFalse2472.00
3508783125636NoneMRF33A1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. ESCOM SR 2023-24 I No. 32.11 Pg.13 3.5Cx50 Sqmm Al Ar cable ESCOM SR 2023-24 I No. 32.11 Pg.13Km184342.19184342.190.03FalseNoneNoneFalseNoneFalse5530.26570
3508784125636NoneMRF33B4Cx25 Sq mm Al Ar cable. ESCOM SR 2023-24 I No. 32.08 Pg.13Km185239.32185239.320.02FalseNoneNoneFalseNoneFalse3704.78640
3508785125636NoneMRF33C4Cx16 Sq mm Al Ar cable ESCOM SR 2023-24 I No. 32.05 Pg.13Km146097.26146097.260.02FalseNoneNoneFalseNoneFalse2921.94520
3508786125636NoneMRF33D4Cx10 Sq mm Cu Ar cable. ESCOM SR 2023-24 I No. 32.03 Pg.13Km121544.12121544.120.02FalseNoneNoneFalseNoneFalse2430.88240
3508787125636NoneMRF34ALaying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 to 25 sqmm ESCOM SR 2023-24 I No. 21.05 Pg.52Km21512.5821512.580.06FalseNoneNoneFalseNoneFalse1290.75480
3508788125636NoneMRF34B35 to 95 Sqmm .ESCOM SR 2023-24 I No. 21.06 Pg.52Km32073.1732073.170.03FalseNoneNoneFalseNoneFalse962.19510
3508789125636NoneMRF35Earth Work Excavation for pipeline/cables by manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shorting, strutting,barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a redius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth sides of foundations etc. in layers not exceeding 20 cm in depth, consolidated each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.(P.No.06, I.No 1.6.1 in KPWD CSR volume-1, 2023-24Cum498.52498.526.75FalseNoneNoneFalseNoneFalse3365.010
3508790125636NoneMRF36ACable Joint and wiring (for HT & LT UG Cable). LT UG Cable. Heat shrinkable Type Terminations ESCOM SR 2023-24 I No. 22.13 Pg.53 35 to 95 Sqmm .ESCOM SR 2023-24 I No. 22.14 Pg.53Set195.7195.72.0FalseNoneNoneFalseNoneFalse391.40
3508791125636NoneMRF36B2.5 to 25 Sqmm .ESCOM SR 2023-24 I No. 22.13 Pg.53Set96.8296.8212.0FalseNoneNoneFalseNoneFalse1161.840
3508792125636NoneMRF37ASupplying & Fixing heavy guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws. PWD Electrical SR-2023-24, ITEM NO:1.1 ,CH-1, PAGE NO-2 19/20mm dia PVC 2mm thick conduit.PWD Electrical SR-2023-24, ITEM NO:1.1.1 ,CH-1, PAGE NO-2Mtr71.0771.0725.0FalseNoneNoneFalseNoneFalse1776.750
3508793125636NoneMRF37B25mm dia PVC 2mm thick conduit.PWD Electrical SR-2023-24, ITEM NO:1.1.2 ,CH-1, PAGE NO-2Mtr83.4383.4325.0FalseNoneNoneFalseNoneFalse2085.750
3508794125636NoneMRF37C32mm dia PVC 2.5mm thick conduit.PWD Electrical SR-2023-24, ITEM NO:1.1.3 ,CH-1, PAGE NO-2Mtr109.18109.1820.0FalseNoneNoneFalseNoneFalse2183.60
3508795125636NoneMRF37D40mm dia PVC 2.5mm thick conduit.PWD Electrical SR-2023-24, ITEM NO:1.1.4 ,CH-1, PAGE NO-2Mtr153.47153.4720.0FalseNoneNoneFalseNoneFalse3069.40
3508796125636NoneMRF38ASupplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5 Sqmm (Phase&Neutral) & 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gangbox, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Electrical SR-2023-24, ITEM NO:2.1,CH-1, PAGE NO-5 PNos293.55293.5510.0FalseNoneNoneFalseNoneFalse2935.50
3508797125636NoneMRF38BMedium point above 3Mtr upto 6Mtr from tapping point to outlet via switch .PWD Electrical SR-2023-24, ITEM NO:2.1.2 ,CH-1, PAGE NO-5Nos405.82405.8210.0FalseNoneNoneFalseNoneFalse4058.20
3508798125636NoneMRF38CLong point above 6Mtr upto 10Mtr from tapping point to out let via switch.PWD Electrical SR-2023-24, ITEM NO:2.1.3 ,CH-1, PAGE NO-5 Nos587.1587.16.0FalseNoneNoneFalseNoneFalse3522.60
3508799125636NoneMRF38DTwo outlet in a row, above 3Mtr upto 6Mtr from tapping point to outlet via switches.PWD Electrical SR-2023-24, ITEM NO:2.1.4 ,CH-1, PAGE NO-5Nos729.24729.245.0FalseNoneNoneFalseNoneFalse3646.20
3508800125636NoneMRF38EThree outlet in a row, above 6Mts upto 10Mtr from tapping point to out let via switches.PWD Electrical SR-2023-24, ITEM NO:2.1.5 ,CH-1, PAGE NO-5Nos1066.051066.054.0FalseNoneNoneFalseNoneFalse4264.20
3508801125636NoneMRF39AWiring for lighting /power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010. PWD Electrical SR-2023-24, ITEM NO:2.3 ,CH-1, PAGE NO-5 1.0 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.1 ,CH-1, PAGE NO-5Mtr19.5719.57200.0FalseNoneNoneFalseNoneFalse3914.00
3508802125636NoneMRF39B1.5 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.2 ,CH-1, PAGE NO-5Mtr26.7826.78100.0FalseNoneNoneFalseNoneFalse2678.00
3508803125636NoneMRC39C2.5 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.3 ,CH-1, PAGE NO-5Mtr43.2643.26150.0FalseNoneNoneFalseNoneFalse6489.00
3508804125636NoneMRF39D4.0 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.4 ,CH-1, PAGE NO-5Mtr64.8964.8975.0FalseNoneNoneFalseNoneFalse4866.750
3508805125636NoneMRF39E6.0 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.5 ,CH-1, PAGE NO-5Mtr94.7694.7650.0FalseNoneNoneFalseNoneFalse4738.00
3508806125636NoneMRF40ASupplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos.of machine screws, bolts nuts etc.,complete on the existing metal/PVC box. 10 - 12 Module Polycarbonate switch box plate.PWD Electrical SR-2023-24, ITEM NO:3.5.6 ,CH-3, PAGE NO-8 Nos354.32354.325.0FalseNoneNoneFalseNoneFalse1771.60
3508807125636NoneMRF40B3 Module Polycarbonate switch box plate.PWD Electrical SR-2023-24, ITEM NO:3.5.2 ,CH-3, PAGE NO-5Nos165.83165.834.0FalseNoneNoneFalseNoneFalse663.320
3508808125636NoneMRF41ASupplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cuttingin Brick/C.C wall, including necessary rawl plugs,Machine/NF screws etc., complete. 3 Way PWD Electrical SR-2023-24, ITEM NO:3.3.2 ,CH-3, PAGE NO-8 Nos127.72127.725.0FalseNoneNoneFalseNoneFalse638.60
3508809125636NoneMRF41B10-12 Way PWD Electrical SR-2023-24, ITEM NO:3.3.6 ,CH-3, PAGE NO-8Nos268.83268.835.0FalseNoneNoneFalseNoneFalse1344.150
3508810125636NoneMRF42ASupplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Switches & sockets outlets in Existing modular box. PWD Electrical SR-2023-24, ITEM NO:3.6 ,CH-3, PAGE NO-9 6A one way switch.PWD Electrical SR-2023-24, ITEM NO:3.6.1 ,CH-3, PAGE NO-9Nos105.06105.064.0FalseNoneNoneFalseNoneFalse420.240
3508811125636NoneMRF42B6A 3 way socket.PWD Electrical SR-2023-24, ITEM NO:3.6.3 ,CH-3, PAGE NO-9 Nos176.13176.134.0FalseNoneNoneFalseNoneFalse704.520
3508812125636NoneMRF42C6/16A Universal socket.PWD Electrical SR-2023-24, ITEM NO:3.6.10 ,CH-3, PAGE NO-9Nos243.08243.082.0FalseNoneNoneFalseNoneFalse486.160
3508813125636NoneMRF42Supply & fixi ng of LED flood light 100WSpecification as per PWD Electrical SR-2023-24, ITEM NO:11.9.2, PAGE NO-46Nos9770.589770.5810.0FalseNoneNoneFalseNoneFalse97705.80
3508814125636NoneMRF44GI/Copper strips for grounding connections, using necessary fixing materials as required.25x3mm GI Strip.PWD Electrical SR-2023-24, ITEM NO:12.58.2 ,CH-12, PAGE NO-54 Mtr84.4684.4640.0FalseNoneNoneFalseNoneFalse3378.40
3508815125636NoneMRF452 mm thick perforated cable GI tray with one xisting MS angle support using necessary GI bolts/nuts and washer or welding as required.(PWD Electrical SR-2023-24, ITEM NO:12.59.2 ,CH-12, PAGE NO-55 Mtr604.61604.6115.0FalseNoneNoneFalseNoneFalse9069.150
3508816125636NoneMRF46Supplying,fixing,wiring,earth electrode for grounding conduits,I.C.cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5m long buried in a pit.The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth.The connection from the pipe to the conduit etc.,is to be established through GIwire of size asper lSI specification 7.3.3.of IS 732 using 12mm dia bolts,nuts,washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia.PWD Electrical SR-2023-24, ITEM NO:12.56,CH-12, PAGE NO-54 Nos3615.33615.32.0FalseNoneNoneFalseNoneFalse7230.60
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17206927350000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17206927350000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued governmentNone
17206927350000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17206927350000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17206927350000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17206927350000NoneNoneELIGIBILITYTenders from joint ventures are not acceptableNone
17206927350000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practice issued government of karnatakaNone
17206927350000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17206927350000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17206927350000NoneNoneELIGIBILITYAll Terms & conditions are as per Tender documentsNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneSatisfactory completed, at least one Building works of value not less than Rs. 49.95 Lakhs as prime contractor In support of the above, work done certificate has to be duly certified by an officer not below the rank of Executive Engineer with indent number.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneExecuted in one year the following minimum quantities of work signed by officer not below the rank of Executive Engineer 1.Earth work excavation/Embankment:497.49Cum, Cement concrete/RCC:192.24 cum, Size stone masonry:33.43cum, Concrete solid blocks:219.54 sqm, TMT steel:7.01 MT and structural steel:21808.00 kgs.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneSatisfactory Performance Certificate
NoneNoneNoneNoneThe tenderer in its name should have in the last five years i.e., 2019-20 to 2023-24 Achieved in at least two financial years a minimum annual financial turnover of Rs.99.90 Lakhs Turnover certificate from CA with valid UDIN No. to be furnished along with necessary documents.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneLiquid assets and or availability of credit facilities of not less than Rs. 25.40 Lakhs Credit lines/ letters of credit/ certificates from banks for meeting the fund requirement etc from nationalized/schedule bank.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneGST RegistrationFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneValid PWD CLASS III and above Contractor Registration certificate shall be furnished. not below the rank of SE.OthersPWD Registration class3 and above
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
PWD Registration class3 and aboveTrueTechnical Bid
Annual turnover certificate for past 5 financial yearsTrueTechnical Bid
Similar work done certificate as per tender documentTrueTechnical Bid
GST CERTIFICATETrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone