| 1721037050000 | 0 | None | None | Buildings | Construction of Septic Tank and Soak pit and electrical works wiring and electrical fixtures for aspirational public toilet near old tehsildar office within yellapur town panchayat | 303622.27 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3526019 | 126730 | None | code01 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.(CSR VOL I for the year 2023-24. I. No.1.4.page no-5) | Each | 256.48 | 256.48 | 26.95 | False | None | None | False | None | False | 6912.136 | 0 | | 3526020 | 126730 | None | code02 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. (Item No2.1.5, Page No.15, V1 P.W.D.C S.R. 2023-24 ) | Cum | 6894.72 | 6894.72 | 2.45 | False | None | None | False | None | False | 16892.064 | 0 | | 3526021 | 126730 | None | code03 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers not exceeding 150 mm thickness, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates(CSR Vol-I, Item no 2.3.1,2023-24, P.No-16) | Mtr | 7789.94 | 7789.94 | 6.092 | False | None | None | False | None | False | 47456.31448 | 0 | | 3526022 | 126730 | None | code04 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ( CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 17) | Cum | 11496.24 | 11496.24 | 1.62 | False | None | None | False | None | False | 18623.9088 | 0 | | 3526023 | 126730 | None | code05 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, ping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Canal & Allied Works (Item No2.11.f, Page No.18, V1 P.W.D.C S.R. 2023-24 ) | t | 100811.2 | 100811.2 | 0.66 | False | None | None | False | None | False | 66535.392 | 0 | | 3526024 | 126730 | None | code06 | Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.(CSR VoII-Item no6.3,2023-24 page no-13) | No | 9938.88 | 9938.88 | 1.52 | False | None | None | False | None | False | 15107.0976 | 0 | | 3526025 | 126730 | None | code07 | Filling of dry waste brick in soak pit (Lum sum) | Mtr | 3360.0 | 3360.0 | 1.3 | False | None | None | False | None | False | 4368.0 | 0 | | 3526026 | 126730 | None | code08 | Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary ( CSR 2023-24 VOI 5/Page No. 2 Item No. 1.2.2 ) | Mtr | 87.36 | 87.36 | 5.0 | False | None | None | False | None | False | 436.8 | 0 | | 3526027 | 126730 | None | code09 | Supplying heavy gauge PVC conduit pipe ……mm dia ....... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary (Page No.3 Item No. 1.2.1) | Each | 73.92 | 73.92 | 15.0 | False | None | None | False | None | False | 1108.8 | 0 | | 3526028 | 126730 | None | code10 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A. (Page No. 5 Item No.2.1.1) | Point | 319.2 | 319.2 | 5.0 | False | None | None | False | None | False | 1596.0 | 0 | | 3526029 | 126730 | None | code11 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A. (Page No. 5 Item No.2.1.2) | Point | 441.28 | 441.28 | 8.0 | False | None | None | False | None | False | 3530.24 | 0 | | 3526030 | 126730 | None | code12 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A. (Page No. 5 Item No.2.1.3) | Point | 635.04 | 635.04 | 1.0 | False | None | None | False | None | False | 635.04 | 0 | | 3526031 | 126730 | None | code13 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A. (Page No. 6 Item No.2.3.2) | Mtr | 29.12 | 29.12 | 200.0 | False | None | None | False | None | False | 5824.0 | 0 | | 3526032 | 126730 | None | code14 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A.(Page No.5& 6 Item No.2.3.3) | Mtr | 44.8 | 44.8 | 90.0 | False | None | None | False | None | False | 4032.0 | 0 | | 3526033 | 126730 | None | code15 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.(Page No. 9 Item No.3.5.4) | Each | 246.4 | 246.4 | 1.0 | False | None | None | False | None | False | 246.4 | 0 | | 3526034 | 126730 | None | code16 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.(Item No.3.5.5) | Each | 338.24 | 338.24 | 1.0 | False | None | None | False | None | False | 338.24 | 0 | | 3526035 | 126730 | None | code17 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (Page No. 9 Item No. 3.6.1) | Each | 114.24 | 114.24 | 11.0 | False | None | None | False | None | False | 1256.64 | 0 | | 3526036 | 126730 | None | code18 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (Page No. 9 Item No. 3.6.3) | Each | 191.52 | 191.52 | 1.0 | False | None | None | False | None | False | 191.52 | 0 | | 3526037 | 126730 | None | code19 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. ( Item No. 3.6.9 page no 9) | Each | 365.12 | 365.12 | 2.0 | False | None | None | False | None | False | 730.24 | 0 | | 3526038 | 126730 | None | code20 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. (Item no 5.18.6 page no 9 ) | Each | 1234.24 | 1234.24 | 1.0 | False | None | None | False | None | False | 1234.24 | 0 | | 3526039 | 126730 | None | code21 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.( CSR V6/ Item no 12.57 page no 54) | Each | 4766.72 | 4766.72 | 1.0 | False | None | None | False | None | False | 4766.72 | 0 | | 3526040 | 126730 | None | code22 | Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500degree K, CRI more than 70%. efficacy more than 80 lumen per W, life more than 25000burning hours and Compliance to IS 10322/IEC 60598, LM 79& LM 80. The LED are driven by HF electronic driver ntegrated in the system, with PF more than 0.95, power loss should less than 5% of lamp Wage., short circuit & open circuit protection to be integratedin the circuit, THD less than 20%, Life as per LM 79. Theoperating input voltage should be between 130 to 275 V. BISApproved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.(CSR V-6/Item11.11.3 page no 47 | Each | 166.88 | 166.88 | 9.0 | False | None | None | False | None | False | 1501.92 | 0 | | 3526041 | 126730 | None | code23 | Supply of round/square recess/surface mounted rollingtype LED Down light with ...... W GU 10 LED Lamp RibFabricated from diecast aluminium with white powdercoated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained bycircular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI more than 80. Power Input: 220-240V@50/60Hz & Power factor more than 0.9 along with CE approved. 2years Warranty against any nufacturing defect working understandard electrical condition.(CSR V-6/Item11.11.5 page no 47 | Each | 935.2 | 935.2 | 2.0 | False | None | None | False | None | False | 1870.4 | 0 | | 3526042 | 126730 | None | code24 | Providing and errection of Napkin pad burning incinator in toilet as per instruction of Engineering incharge | Each | 75000.0 | 75000.0 | 1.0 | False | None | None | False | None | False | 75000.0 | 0 | | 3526043 | 126730 | None | code25 | Supplying capacitor type ceiling fan complete with down rod blades,shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.( CSR V6/ Item no 6.3.2 page no 30) | Each | 3394.72 | 3394.72 | 1.0 | False | None | None | False | None | False | 3394.72 | 0 | | 3526044 | 126730 | None | code26 | Supplying.....litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate. 2kW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall ompletely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer ontainer provided with heavy gauge brackets for wall mounting.( CSR V6/ Item no 7.1.2 page no 34) | Each | 9816.8 | 9816.8 | 1.0 | False | None | None | False | None | False | 9816.8 | 0 | | 3526045 | 126730 | None | code27 | White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap( CSR V2/ Item no 14.7.2 page no 132) | Each | 2868.32 | 2868.32 | 2.0 | False | None | None | False | None | False | 5736.64 | 0 | | 3526046 | 126730 | None | code28 | Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | cm | 4.48 | 4.48 | 1000.0 | False | None | None | False | None | False | 4480.0 | 0 |
|