tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1720599939000 | 0 | None | None | Buildings | Construction of Health and Wellness Centre at Murakibavi in Bailhongal Taluk, Belagavi District (Civil GF Work) | 3606159.69 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3503517 | 125274 | None | Common PWD SR 23-24 V-1 pg no 8 item no 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m | Cum | 120.36 | 120.36 | 144.97 | False | None | None | False | None | False | 17448.5892 | 0 | 3503518 | 125274 | None | Common PWD SR 23-24 V-1 pg no 15 item no 2.1.3 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7067.02 | 7067.02 | 18.38 | False | None | None | False | None | False | 129891.8276 | 0 | 3503519 | 125274 | None | Common PWD SR 23-24 V-1 pg no 15 item no 2.2.1 | Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Including Formwork) for FOOTINGS | Cum | 8012.15 | 8012.15 | 14.89 | False | None | None | False | None | False | 119300.9135 | 0 | 3503520 | 125274 | None | Common PWD SR 23-24 V-1 pg no 15 item no 2.2.1 | Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Including Formwork) for PEDESTALS | Cum | 8160.53 | 8160.53 | 1.79 | False | None | None | False | None | False | 14607.3487 | 0 | 3503521 | 125274 | None | Common PWD SR 23-24 V-1 pg no 16 item no 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Including Formwork) for COLUMNS-GROUND FLOOR | Cum | 13299.78 | 13299.78 | 7.14 | False | None | None | False | None | False | 94960.4292 | 0 | 3503522 | 125274 | None | Common PWD SR 23-24 V-1 pg no 16 item no 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Including Formwork) for PLINTH BEAM, SLAB & STAIRCASE-GROUND FLOOR | Cum | 11735.1 | 11735.1 | 30.15 | False | None | None | False | None | False | 353813.265 | 0 | 3503523 | 125274 | None | Common PWD SR 23-24 V-1 pg no 16 item no 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Including Formwork) for RCC BEAMS & LINTEL-GROUND ROOF | Cum | 12517.44 | 12517.44 | 11.59 | False | None | None | False | None | False | 145077.1296 | 0 | 3503524 | 125274 | None | Common PWD SR 23-24 V-1 pg no 7 item no 1.9 | 1.9 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 313.88 | 313.88 | 180.15 | False | None | None | False | None | False | 56545.482 | 0 | 3503525 | 125274 | None | Common PWD SR 23-24 V-1 pg no 15 item no 2.1.4 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7336.06 | 7336.06 | 3.02 | False | None | None | False | None | False | 22154.9012 | 0 | 3503526 | 125274 | None | Common PWD SR 23-24 V-1 pg no 16 item no 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Including Formwork) for Chajja | Cum | 11343.93 | 11343.93 | 0.39 | False | None | None | False | None | False | 4424.1327 | 0 | 3503527 | 125274 | None | Common PWD SR 23-24 V-1 pg no 18 item no 2.11 a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings | Tonne | 105559.26 | 105559.26 | 5.61 | False | None | None | False | None | False | 592187.4486 | 0 | 3503528 | 125274 | None | Common PWD SR 23-24 V-2 pg no 9 item no 5.1.1 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6620.98 | 6620.98 | 8.06 | False | None | None | False | None | False | 53365.0988 | 0 | 3503529 | 125274 | None | Common PWD SR 23-24 V-2 pg no 13 item no 6.3 | Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 10471.32 | 10471.32 | 39.87 | False | None | None | False | None | False | 417491.5284 | 0 | 3503530 | 125274 | None | Common PWD SR 23-24 V-2 pg no 14 item no 6.15 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Sqm | 1218.94 | 1218.94 | 43.65 | False | None | None | False | None | False | 53206.731 | 0 | 3503531 | 125274 | None | Common PWD SR 23-24 V-2 pg no 100 item no 12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 116601.7 | 116601.7 | 0.47 | False | None | None | False | None | False | 54802.799 | 0 | 3503532 | 125274 | None | Common PWD SR 23-24 V-2 pg no 104 item no 12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m.including cost of materials, labour charges, complete as per specifications. | No | 1198.88 | 1198.88 | 7.0 | False | None | None | False | None | False | 8392.16 | 0 | 3503533 | 125274 | None | Common PWD SR 23-24 V-2 pg no A-25 item no 444 | Hold fasts | No | 59.0 | 59.0 | 36.0 | False | None | None | False | None | False | 2124.0 | 0 | 3503534 | 125274 | None | Common PWD SR 23-24 V-2 pg no 105 item no 12.57.5 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.35 mm thick one side teak and one side commercial | Sqm | 4598.46 | 4598.46 | 17.01 | False | None | None | False | None | False | 78219.8046 | 0 | 3503535 | 125274 | None | Common PWD SR 23-24 V-2 pg no 110 item no 12.9 | 12.90 Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 7946.12 | 7946.12 | 12.65 | False | None | None | False | None | False | 100518.418 | 0 | 3503536 | 125274 | None | Common PWD SR 23-24 V-2 pg no 109 item no 12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead freewith gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness.Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 6748.42 | 6748.42 | 1.32 | False | None | None | False | None | False | 8907.9144 | 0 | 3503537 | 125274 | None | Common PWD SR 23-24 V-2 pg no 86 item no 11.34A | 11.34A Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kg | 198.24 | 198.24 | 293.27 | False | None | None | False | None | False | 58137.8448 | 0 | 3503538 | 125274 | None | Common PWD SR 23-24 V-2 pg no 104 item no 12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. | m | 375.24 | 375.24 | 19.8 | False | None | None | False | None | False | 7429.752 | 0 | 3503539 | 125274 | None | Common PWD SR 23-24 V-2 pg no 104 item no 12.55.2 | Solid panel prelam pvc door shutter. Providing and fixing 30mm thick factory made rigid foam Prelam panelled Door Shutters made from M.S. Tube of 19x19mm, 19 guage for styles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form styles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the styles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm. Aluminium hinges. with one side prelam | Sqm | 2407.2 | 2407.2 | 6.3 | False | None | None | False | None | False | 15165.36 | 0 | 3503540 | 125274 | None | Common PWD SR 23-24 V-2 pg no 41 item no 8.4.1 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. for ceiling | Sqm | 323.32 | 323.32 | 85.98 | False | None | None | False | None | False | 27799.0536 | 0 | 3503541 | 125274 | None | Common PWD SR 23-24 V-2 pg no 42 item no 8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 411.82 | 411.82 | 440.24 | False | None | None | False | None | False | 181299.6368 | 0 | 3503542 | 125274 | None | Common PWD SR 23-24 V-2 pg no 50 item no 8.51 | 8.51 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 118.0 | 118.0 | 526.22 | False | None | None | False | None | False | 62093.96 | 0 | 3503543 | 125274 | None | Common PWD SR 23-24 V-2 pg no 42 item no 8.8 | 8.8 Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing caffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Out side) | Sqm | 437.78 | 437.78 | 297.7 | False | None | None | False | None | False | 130327.106 | 0 | 3503544 | 125274 | None | Common PWD SR 23-24 V-2 pg no 41 item no 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 348.1 | 348.1 | 38.41 | False | None | None | False | None | False | 13370.521 | 0 | 3503545 | 125274 | None | Common PWD SR 23-24 V-2 pg no 149 item no 15.1 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. | Sqm | 964.06 | 964.06 | 37.58 | False | None | None | False | None | False | 36229.3748 | 0 | 3503546 | 125274 | None | Common PWD SR 23-24 V-2 pg no 60 item no 9.12.2 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm | Sqm | 1351.1 | 1351.1 | 87.58 | False | None | None | False | None | False | 118329.338 | 0 | 3503547 | 125274 | None | Common PWD SR 23-24 V-2 pg no 63 item no 9.23 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. | Sqm | 2909.88 | 2909.88 | 23.96 | False | None | None | False | None | False | 69720.7248 | 0 | 3503548 | 125274 | None | Common PWD SR 23-24 V-2 pg no 60 item no 9.11 | 9.11 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. | Sqm | 1049.02 | 1049.02 | 13.06 | False | None | None | False | None | False | 13700.2012 | 0 | 3503549 | 125274 | None | Common PWD SR 23-24 V-2 pg no 65 item no 9.38 | 9.38 Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. | Sqm | 1642.56 | 1642.56 | 38.41 | False | None | None | False | None | False | 63090.7296 | 0 | 3503550 | 125274 | None | Common PWD SR 23-24 V-2 pg no 64 item no 9.36 | Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. | Sqm | 1947.0 | 1947.0 | 5.65 | False | None | None | False | None | False | 11000.55 | 0 | 3503551 | 125274 | None | Common PWD SR 23-24 V-2 pg no 63 item no 9.29 | Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. | Sqm | 5081.08 | 5081.08 | 9.16 | False | None | None | False | None | False | 46542.6928 | 0 | 3503552 | 125274 | None | Common PWD SR 23-24 V-2 pg no 83 item no 11.28 | 11.28 Providing and fixing 304 - grade stainless steel hand rails of 14-gauge pipes for Ramps or Staircase are made out of stainless steel hallow pipes, using 50mm dia for verticals @1.60 mtr c/c are fixed to the ramps or steps by drilling with bolts and 100mm dia MS base plates 10mm gauge for fixing of Vertical pipes 4 - Nos anchor bolts & 40mm dia pipes are fixed horizontally for 2-rows top, one pipes are fixed with vertical pipes another one are fixed with elbows and 25mm dia pipes are fixed horizontally for 2-rows below top measure @ equal intervals including cutting, welding, bending wherever necessary with suitable caps @ tops, bottoms & corners finishing with mat / shining etc., complete including cost and conveyance of all materials, labour for all items of work, HOM of equipment with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. Ramps or Staircase for physically challenged. | Kg | 666.7 | 666.7 | 160.0 | False | None | None | False | None | False | 106672.0 | 0 | 3503553 | 125274 | None | Common PWD SR 23-24 V-2 pg no 48 item no 8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 149.86 | 149.86 | 440.24 | False | None | None | False | None | False | 65974.3664 | 0 | 3503554 | 125274 | None | Common PWD SR 23-24 V-2 pg no 46 item no 8.3 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in- charge. | Sqm | 205.32 | 205.32 | 267.93 | False | None | None | False | None | False | 55011.3876 | 0 | 3503555 | 125274 | None | Common PWD SR 23-24 V-2 pg no 47 item no 8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 59.0 | 59.0 | 13.97 | False | None | None | False | None | False | 824.23 | 0 | 3503556 | 125274 | None | Common PWD SR 23-24 V-2 pg no 48 item no 8.4 | 8.4 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 135.7 | 135.7 | 13.97 | False | None | None | False | None | False | 1895.729 | 0 | 3503557 | 125274 | None | Common PWD SR 23-24 V-2 pg no 47 item no 8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 62.54 | 62.54 | 77.18 | False | None | None | False | None | False | 4826.8372 | 0 | 3503558 | 125274 | None | Common PWD SR 23-24 V-2 pg no 105 item no 12.62 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete | No | 279.66 | 279.66 | 26.0 | False | None | None | False | None | False | 7271.16 | 0 | 3503559 | 125274 | None | Common PWD SR 23-24 V-2 pg no 105 item no 12.58 | Providing and fixing bright finished brass hanging type floor door stopper
with necessary screws, etc. complete | No | 141.6 | 141.6 | 13.0 | False | None | None | False | None | False | 1840.8 | 0 | 3503560 | 125274 | None | Common PWD SR 23-24 V-2 pg no 105 item no 12.6 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. | No | 1241.36 | 1241.36 | 26.0 | False | None | None | False | None | False | 32275.36 | 0 | 3503561 | 125274 | None | Common PWD SR 23-24 V-2 pg no 105 item no 12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete | No | 153.4 | 153.4 | 26.0 | False | None | None | False | None | False | 3988.4 | 0 | 3503562 | 125274 | None | Common PWD SR 23-24 V-1 pg no 9 item no 1.15.2 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting Depth exceeding 1.5 m, but not exceeding 3 m | Cum | 501.5 | 501.5 | 8.06 | False | None | None | False | None | False | 4042.09 | 0 | 3503563 | 125274 | None | Common PWD SR 23-24 V-1 pg no 17 item no 2.5.1 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 20% for Centering and Shuttering. (Including Formwork) | Cum | 9388.08 | 9388.08 | 6.05 | False | None | None | False | None | False | 56797.884 | 0 | 3503564 | 125274 | None | Common PWD SR 23-24 vol-2 pg no 41 item no 8.1.2 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in- charge. | Sqm | 284.38 | 284.38 | 6.0 | False | None | None | False | None | False | 1706.28 | 0 | 3503565 | 125274 | None | Common PWD SR 23-24 vol-2 pg no 41 item no 8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 300.9 | 300.9 | 30.0 | False | None | None | False | None | False | 9027.0 | 0 | 3503566 | 125274 | None | Common PWD SR 23-24 vol-2 pg no 136 item no 15.6 | Providing and laying water proofing treatment to the Water tanks & Liquid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50% applied @ 1.5 kg/m2 for internal side waterproofing in two layers with waiting period of 4- 6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 598.26 | 598.26 | 30.0 | False | None | None | False | None | False | 17947.8 | 0 | 3503567 | 125274 | None | Common PWD SR 23-24 vol-5 pg no 221 item no 18.3 | Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. | No | 2315.16 | 2315.16 | 2.0 | False | None | None | False | None | False | 4630.32 | 0 | 3503568 | 125274 | None | Common PWD SR 23-24 V-2 pg no 188 item no 19.10.2 | Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually/ by mechanical means including stacking of serviceable and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.In cement mortar | Cum | 1181.18 | 1181.18 | 42.12 | False | None | None | False | None | False | 49751.3016 | 0 |
| 1720599939000 | 0 | None | None | Buildings | Construction of Health and Wellness Centre at Murakibavi in Bailhongal Taluk, Belagavi District (Civil FF) | 1768323.41 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3503569 | 125275 | None | Common PWD SR 23-24 V-1 pg no 16 item no 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Including Formwork) for COLUMNS-FIRST FLOOR | Cum | 13432.78 | 13432.78 | 4.22 | False | None | None | False | None | False | 56686.3316 | 0 | 3503570 | 125275 | None | Common PWD SR 23-24 V-1 pg no 16 item no 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Including Formwork) for RCC BEAMS & LINTEL-FIRST FLOOR | Cum | 12642.61 | 12642.61 | 8.11 | False | None | None | False | None | False | 102531.5671 | 0 | 3503571 | 125275 | None | Common PWD SR 23-24 V-1 pg no 16 item no 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Including Formwork) for RCC SLAB-FIRST FLOOR | Cum | 11852.45 | 11852.45 | 6.82 | False | None | None | False | None | False | 80833.709 | 0 | 3503572 | 125275 | None | Common PWD SR 23-24 V-1 pg no 15 item no 2.1.4 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 using 20 mm nominal size graded crushed coarse aggregates. | Cum | 7409.42 | 7409.42 | 1.03 | False | None | None | False | None | False | 7631.7026 | 0 | 3503573 | 125275 | None | Common PWD SR 23-24 V-1 pg no 16 item no 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Including Formwork) for Chajja | Cum | 11457.37 | 11457.37 | 0.46 | False | None | None | False | None | False | 5270.3902 | 0 | 3503574 | 125275 | None | Common PWD SR 23-24 V-1 pg no 18 item no 2.11 (a) | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings | Tonne | 106614.85 | 106614.85 | 1.63 | False | None | None | False | None | False | 173782.2055 | 0 | 3503575 | 125275 | None | Common PWD SR 23-24 V-2 pg no 13 item no 6.3 | Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Sqm | 12356.16 | 12356.16 | 35.16 | False | None | None | False | None | False | 434442.5856 | 0 | 3503576 | 125275 | None | Common PWD SR 23-24 V-2 pg no 14 item no 6.15 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Sqm | 1438.35 | 1438.35 | 42.38 | False | None | None | False | None | False | 60957.273 | 0 | 3503577 | 125275 | None | Common PWD SR 23-24 V-2 pg no 100 item no 12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 117767.72 | 117767.72 | 0.21 | False | None | None | False | None | False | 24731.2212 | 0 | 3503578 | 125275 | None | Common PWD SR 23-24 V-2 pg no 104 item no 12.51 | 12.51 Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | No | 1210.87 | 1210.87 | 4.0 | False | None | None | False | None | False | 4843.48 | 0 | 3503579 | 125275 | None | Common PWD SR 23-24 V-2 pg no A-25 item no 444 | Hold fasts | No | 59.6 | 59.6 | 24.0 | False | None | None | False | None | False | 1430.4 | 0 | 3503580 | 125275 | None | Common PWD SR 23-24 V-2 pg no 105 item no 12.57.5 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.35 mm thick one side teak and one side commercial | Sqm | 4644.44 | 4644.44 | 9.12 | False | None | None | False | None | False | 42357.2928 | 0 | 3503581 | 125275 | None | Common PWD SR 23-24 V-2 pg no 110 item no 12.9 | 12.90 Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 8025.58 | 8025.58 | 10.55 | False | None | None | False | None | False | 84669.869 | 0 | 3503582 | 125275 | None | Common PWD SR 23-24 V-2 pg no 110 item no 12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 6815.9 | 6815.9 | 0.72 | False | None | None | False | None | False | 4907.448 | 0 | 3503583 | 125275 | None | Common PWD SR 23-24 V-2 pg no 86 item no 11.34A | 11.34A Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. | Kg | 200.22 | 200.22 | 236.57 | False | None | None | False | None | False | 47366.0454 | 0 | 3503584 | 125275 | None | Common PWD SR 23-24 V-2 pg no 104 item no 12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. | m | 378.99 | 378.99 | 9.9 | False | None | None | False | None | False | 3752.001 | 0 | 3503585 | 125275 | None | Common PWD SR 23-24 V-2 pg no 104 item no 12.55.2 | Solid panel prelam pvc door shutter. Providing and fixing 30mm thick factory made rigid foam Prelam panelled Door Shutters made from M.S. Tube of 19x19mm, 19 guage for styles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form styles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the styles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm. Aluminium hinges. with one side prelam | Sqm | 2436.04 | 2436.04 | 3.15 | False | None | None | False | None | False | 7673.526 | 0 | 3503586 | 125275 | None | Common PWD SR 23-24 V-2 pg no 41 item no 8.4.1 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 384.95 | 384.95 | 68.7 | False | None | None | False | None | False | 26446.065 | 0 | 3503587 | 125275 | None | Common PWD SR 23-24 V-2 pg no 42 item no 8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 415.94 | 415.94 | 240.55 | False | None | None | False | None | False | 100054.367 | 0 | 3503588 | 125275 | None | Common PWD SR 23-24 V-2 pg no 50 item no 8.51 | 8.51 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 119.18 | 119.18 | 309.26 | False | None | None | False | None | False | 36857.6068 | 0 | 3503589 | 125275 | None | Common PWD SR 23-24 V-2 pg no 42 item no 8.8 | 8.8 Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing caffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Out side) | Sqm | 442.16 | 442.16 | 204.47 | False | None | None | False | None | False | 90408.4552 | 0 | 3503590 | 125275 | None | Common PWD SR 23-24 V-2 pg no 41 item no 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 351.58 | 351.58 | 27.87 | False | None | None | False | None | False | 9798.5346 | 0 | 3503591 | 125275 | None | Common PWD SR 23-24 V-2 pg no 149 item no 15.1 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. | Sqm | 973.7 | 973.7 | 76.26 | False | None | None | False | None | False | 74254.362 | 0 | 3503592 | 125275 | None | Common PWD SR 23-24 V-2 pg no 60 item no 9.12.2 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm | Sqm | 1364.61 | 1364.61 | 55.67 | False | None | None | False | None | False | 75967.8387 | 0 | 3503593 | 125275 | None | Common PWD SR 23-24 V-2 pg no 60 item no 9.11 | 9.11 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. | Sqm | 1059.51 | 1059.51 | 5.98 | False | None | None | False | None | False | 6335.8698 | 0 | 3503594 | 125275 | None | Common PWD SR 23-24 V-2 pg no 65 item no 9.38 | 9.38 Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. | Sqm | 1658.99 | 1658.99 | 27.87 | False | None | None | False | None | False | 46236.0513 | 0 | 3503595 | 125275 | None | Common PWD SR 23-24 V-2 pg no 65 item no 9.36 | Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. | Sqm | 1966.47 | 1966.47 | 5.65 | False | None | None | False | None | False | 11110.5555 | 0 | 3503596 | 125275 | None | Common PWD SR 23-24 V-2 pg no 64 item no 9.29 | Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specification. | Sqm | 5131.9 | 5131.9 | 9.8 | False | None | None | False | None | False | 50292.62 | 0 | 3503597 | 125275 | None | Common PWD SR 23-24 V-2 pg no 48 item no 8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 151.36 | 151.36 | 240.55 | False | None | None | False | None | False | 36409.648 | 0 | 3503598 | 125275 | None | Common PWD SR 23-24 V-2 pg no 46 item no 8.3 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in- charge. | Sqm | 207.37 | 207.37 | 184.02 | False | None | None | False | None | False | 38160.2274 | 0 | 3503599 | 125275 | None | Common PWD SR 23-24 V-2 pg no 45 item no 8.29 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 337.28 | 337.28 | 21.25 | False | None | None | False | None | False | 7167.2 | 0 | 3503600 | 125275 | None | Common PWD SR 23-24 V-2 pg no 47 item no 8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 59.59 | 59.59 | 11.27 | False | None | None | False | None | False | 671.5793 | 0 | 3503601 | 125275 | None | Common PWD SR 23-24 V-2 pg no 48 item no 8.4 | 8.4 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 137.06 | 137.06 | 11.27 | False | None | None | False | None | False | 1544.6662 | 0 | 3503602 | 125275 | None | Common PWD SR 23-24 V-2 pg no 47 item no 8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 63.17 | 63.17 | 21.89 | False | None | None | False | None | False | 1382.7913 | 0 | 3503603 | 125275 | None | Common PWD SR 23-24 V-2 pg no 105 item no 12.62 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete | No | 282.46 | 282.46 | 10.0 | False | None | None | False | None | False | 2824.6 | 0 | 3503604 | 125275 | None | Common PWD SR 23-24 V-2 pg no 105 item no 12.58 | Providing and fixing bright finished brass hanging type floor door stopper
with necessary screws, etc. complete | No | 143.02 | 143.02 | 5.0 | False | None | None | False | None | False | 715.1 | 0 | 3503605 | 125275 | None | Common PWD SR 23-24 V-2 pg no 105 item no 12.6 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. | No | 1253.78 | 1253.78 | 5.0 | False | None | None | False | None | False | 6268.9 | 0 | 3503606 | 125275 | None | Common PWD SR 23-24 V-2 pg no 105 item no 12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete | No | 154.93 | 154.93 | 10.0 | False | None | None | False | None | False | 1549.3 | 0 |
| 1720599939000 | 0 | None | None | Buildings | Construction of Health and Wellness Centre at Murakibavi in Bailhongal Taluk, Belagavi District (Water supply work) | 233651.8 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3503607 | 125276 | None | Common PWD SR 23-24 V-2 pg no 131 item no 14.3.1 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid | Each | 7052.86 | 7052.86 | 2.0 | False | None | None | False | None | False | 14105.72 | 0 | 3503608 | 125276 | None | Common PWD SR 23-24 V-2 pg no 131 item no 14.1.1 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests | Each | 5763.12 | 5763.12 | 2.0 | False | None | None | False | None | False | 11526.24 | 0 | 3503609 | 125276 | None | Common PWD SR 23-24 V-2 pg no 133 item no 14.7.8 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow including operated levers | Each | 4853.34 | 4853.34 | 2.0 | False | None | None | False | None | False | 9706.68 | 0 | 3503610 | 125276 | None | Common PWD SR 23-24 V-2 pg no 135 item no 14.22A | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. | Each | 955.8 | 955.8 | 2.0 | False | None | None | False | None | False | 1911.6 | 0 | 3503611 | 125276 | None | Common PWD SR 23-24 V-2 pg no 135 item no 14.22B | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic
wall mixer of quality & make as approved by Engineer in charge. | Each | 6563.16 | 6563.16 | 2.0 | False | None | None | False | None | False | 13126.32 | 0 | 3503612 | 125276 | None | CommonPWD SR 23-24 V-2 pg no 133 item no 14.10.1.2 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 510x1040 mm bowl depth 225 mm | Each | 6363.74 | 6363.74 | 1.0 | False | None | None | False | None | False | 6363.74 | 0 | 3503613 | 125276 | None | Common PWD SR 23-24 V-2 pg no 136 item no 14.29 | Providing and fixing 100 mm sand cast Iron grating for gully trap. | Each | 55.46 | 55.46 | 7.0 | False | None | None | False | None | False | 388.22 | 0 | 3503614 | 125276 | None | Common PWD SR 23-24 V-2 pg no 127 item no 13.59 | Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete | Each | 259.6 | 259.6 | 5.0 | False | None | None | False | None | False | 1298.0 | 0 | 3503615 | 125276 | None | Common PWD SR 23-24 V-2 pg no 137 item no 14.36.2 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour: Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 g | Each | 109.74 | 109.74 | 5.0 | False | None | None | False | None | False | 548.7 | 0 | 3503616 | 125276 | None | Common PWD SR 23-24 V-2 pg no 137 item no 14.40.1 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour:450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 g. | Each | 564.04 | 564.04 | 2.0 | False | None | None | False | None | False | 1128.08 | 0 | 3503617 | 125276 | None | Common PWD SR 23-24 V-2 pg no 121 item no 13.25 | Providing and fixing PTMT swivelling shower, 15 mm nominal bore,
weighing not less than 40 gms | No | 172.28 | 172.28 | 2.0 | False | None | None | False | None | False | 344.56 | 0 | 3503618 | 125276 | None | Common PWD SR 23-24 V-5 pg no 113 item no 10.1.5 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: 75 mm dia, 6 kg/sqcm & class 3 | m | 259.6 | 259.6 | 15.0 | False | None | None | False | None | False | 3894.0 | 0 | 3503619 | 125276 | None | Common PWD SR 23-24 V-5 pg no 113 item no 10.1.6 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: 90 mm dia,6 kg/sqcm & class 3 | m | 346.92 | 346.92 | 10.0 | False | None | None | False | None | False | 3469.2 | 0 | 3503620 | 125276 | None | Common PWD SR 23-24 V-5 pg no 113 item no 10.1.7 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: 110mm dia,6 kg/sqcm & class 3 | m | 484.98 | 484.98 | 8.0 | False | None | None | False | None | False | 3879.84 | 0 | 3503621 | 125276 | None | Common PWD SR 23-24 V-5 pg no 113 item no 10.1.8 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: 140mm dia,6 kg/sqcm & class 3 | m | 689.12 | 689.12 | 18.0 | False | None | None | False | None | False | 12404.16 | 0 | 3503622 | 125276 | None | Common PWD SR 23-24 V-2 pg no 122 item no 13.32.1 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm dia | m | 364.62 | 364.62 | 20.0 | False | None | None | False | None | False | 7292.4 | 0 | 3503623 | 125276 | None | Common PWD SR 23-24 V-2 pg no 122 item no 13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20mm dia | m | 447.22 | 447.22 | 15.0 | False | None | None | False | None | False | 6708.3 | 0 | 3503624 | 125276 | None | Common PWD SR 23-24 V-2 pg no 122 item no 13.33.1 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 15 mm dia | m | 195.88 | 195.88 | 35.0 | False | None | None | False | None | False | 6855.8 | 0 | 3503625 | 125276 | None | Common PWD SR 23-24 V-2 pg no 122 item no 13.33.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 25 mm dia | m | 349.28 | 349.28 | 30.0 | False | None | None | False | None | False | 10478.4 | 0 | 3503626 | 125276 | None | Common PWD SR 23-24 V-2 pg no 123 item no 13.33.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work.40 mm dia | m | 562.86 | 562.86 | 20.0 | False | None | None | False | None | False | 11257.2 | 0 | 3503627 | 125276 | None | Common PWD SR 23-24 V-2 pg no 125 item no 13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter | m | 343.38 | 343.38 | 40.0 | False | None | None | False | None | False | 13735.2 | 0 | 3503628 | 125276 | None | Common PWD SR 23-24 V-2 pg no 120 item no 13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. | l | 10.62 | 10.62 | 4500.0 | False | None | None | False | None | False | 47790.0 | 0 | 3503629 | 125276 | None | Common PWD SR 23-24 V-5 pg no 191 item no 16.9 | Constructing brick masonry chamber of internal dimension 600x600mmand depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. | Each | 6435.72 | 6435.72 | 3.0 | False | None | None | False | None | False | 19307.16 | 0 | 3503630 | 125276 | None | Common PWD SR 23-24 V-2 pg no A-16 item no 166 | C.P. Brass stop cock (concealed) 15 mm | No | 619.5 | 619.5 | 12.0 | False | None | None | False | None | False | 7434.0 | 0 | 3503631 | 125276 | None | Common PWD SR 23-24 V-2 pg no A-15 item no 109 | Brass full way valve with C.I. wheel (screwed end) 25 mm dia | No | 442.5 | 442.5 | 2.0 | False | None | None | False | None | False | 885.0 | 0 | 3503632 | 125276 | None | Common PWD SR 23-24 V-2 pg no 116 item no 13.2.1 | Brass bib-cock 15 mm dia | Each | 337.48 | 337.48 | 3.0 | False | None | None | False | None | False | 1012.44 | 0 | 3503633 | 125276 | None | CommonPWD SR 23-24 V-2 pg no 136 item no 14.28.2.2 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines 40mm dia pipes, From wash basin waste lines | m | 108.56 | 108.56 | 15.0 | False | None | None | False | None | False | 1628.4 | 0 | 3503634 | 125276 | None | Common PWD SR 23-24 V-2 pg no 121 item no 13.23.5 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 50 mm nominal bore, 242mm long, weighing not less than 1240 g | No | 1585.92 | 1585.92 | 2.0 | False | None | None | False | None | False | 3171.84 | 0 | 3503635 | 125276 | None | Common PWD SR 23-24 V-5 pg no 149 item no 13.4.1 | Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc complete,. 0.50 HP/0.37kW - 5 STG stage | Each | 12000.6 | 12000.6 | 1.0 | False | None | None | False | None | False | 12000.6 | 0 |
| 1720599939000 | 0 | None | None | Buildings | Construction of Health and Wellness Centre at Murakibavi in Bailhongal Taluk, Belagavi District (Electrical work) | 366131.32 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3503636 | 125277 | None | Common PWD SR 23-24 V-6 pg no 5 item no 2.2.1 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch | Point | 317.42 | 317.42 | 18.0 | False | None | None | False | None | False | 5713.56 | 0 | 3503637 | 125277 | None | Common PWD SR 23-24 V-6 pg no 5 item no 2.2.2 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch | Point | 447.22 | 447.22 | 30.0 | False | None | None | False | None | False | 13416.6 | 0 | 3503638 | 125277 | None | Common PWD SR 23-24 V-6 pg no 5 item no 2.2.3 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch | Point | 654.9 | 654.9 | 15.0 | False | None | None | False | None | False | 9823.5 | 0 | 3503639 | 125277 | None | Common PWD SR 23-24 V-6 pg no 8 item no 3.4.1 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 1-2Way | Each | 162.84 | 162.84 | 6.0 | False | None | None | False | None | False | 977.04 | 0 | 3503640 | 125277 | None | Common PWD SR 23-24 V-6 pg no 8 item no 3.4.2 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 3 way | Each | 187.62 | 187.62 | 2.0 | False | None | None | False | None | False | 375.24 | 0 | 3503641 | 125277 | None | Common PWD SR 23-24 V-6 pg no 8 item no 3.4.3 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 4-5Way | Each | 208.86 | 208.86 | 2.0 | False | None | None | False | None | False | 417.72 | 0 | 3503642 | 125277 | None | Common PWD SR 23-24 V-6 pg no 8 item no 3.4.4 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 6Way | Each | 259.6 | 259.6 | 10.0 | False | None | None | False | None | False | 2596.0 | 0 | 3503643 | 125277 | None | Common PWD SR 23-24 V-6 pg no 8 item no 3.4.5 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 8 Way | Each | 307.98 | 307.98 | 6.0 | False | None | None | False | None | False | 1847.88 | 0 | 3503644 | 125277 | None | Common PWD SR 23-24 V-6 pg no 8 item no 3.4.6 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 10-12Way | Each | 376.42 | 376.42 | 2.0 | False | None | None | False | None | False | 752.84 | 0 | 3503645 | 125277 | None | Common PWD SR 23-24 V-6 pg no 8 item no 3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1-2 Module | Each | 161.66 | 161.66 | 6.0 | False | None | None | False | None | False | 969.96 | 0 | 3503646 | 125277 | None | Common PWD SR 23-24 V-6 pg no 8 item no 3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.3 Module | Each | 189.98 | 189.98 | 2.0 | False | None | None | False | None | False | 379.96 | 0 | 3503647 | 125277 | None | Common PWD SR 23-24 V-6 pg no 8 item no 3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4Module | Each | 206.5 | 206.5 | 2.0 | False | None | None | False | None | False | 413.0 | 0 | 3503648 | 125277 | None | Common PWD SR 23-24 V-6 pg no 8 item no 3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6Module | Each | 276.12 | 276.12 | 10.0 | False | None | None | False | None | False | 2761.2 | 0 | 3503649 | 125277 | None | Common PWD SR 23-24 V-6 pg no 8 item no 3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module | Each | 335.12 | 335.12 | 6.0 | False | None | None | False | None | False | 2010.72 | 0 | 3503650 | 125277 | None | Common PWD SR 23-24 V-6 pg no 8 item no 3.5.6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.10-12Module | Each | 405.92 | 405.92 | 2.0 | False | None | None | False | None | False | 811.84 | 0 | 3503651 | 125277 | None | Common PWD SR 23-24 V-6 pg no 9 item no 3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch | Each | 120.36 | 120.36 | 50.0 | False | None | None | False | None | False | 6018.0 | 0 | 3503652 | 125277 | None | Common PWD SR 23-24 V-6 pg no 9 item no 3.6.2 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps Two way Switch | Each | 195.88 | 195.88 | 6.0 | False | None | None | False | None | False | 1175.28 | 0 | 3503653 | 125277 | None | Common PWD SR 23-24 V-6 pg no 9 item no 3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps 3way socket | Each | 201.78 | 201.78 | 10.0 | False | None | None | False | None | False | 2017.8 | 0 | 3503654 | 125277 | None | Common PWD SR 23-24 V-6 pg no 9 item no 3.6.8 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Bell push | Each | 208.86 | 208.86 | 2.0 | False | None | None | False | None | False | 417.72 | 0 | 3503655 | 125277 | None | Common PWD SR 23-24 V-6 pg no 9 item no 3.6.4 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. | Each | 421.26 | 421.26 | 12.0 | False | None | None | False | None | False | 5055.12 | 0 | 3503656 | 125277 | None | Common PWD SR 23-24 V-6 pg no 9 item no 3.6.9 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch | Each | 384.68 | 384.68 | 6.0 | False | None | None | False | None | False | 2308.08 | 0 | 3503657 | 125277 | None | Common PWD SR 23-24 V-6 pg no 9 item no 3.6.10 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket | Each | 278.48 | 278.48 | 6.0 | False | None | None | False | None | False | 1670.88 | 0 | 3503658 | 125277 | None | Common PWD SR 23-24 V-6 pg no 9 item no 3.6.11 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.TV/Telephone socket | Each | 184.08 | 184.08 | 2.0 | False | None | None | False | None | False | 368.16 | 0 | 3503659 | 125277 | None | Common PWD SR 23-24 V-6 pg no 48 item no 12.2.1 | Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell | Each | 290.28 | 290.28 | 1.0 | False | None | None | False | None | False | 290.28 | 0 | 3503660 | 125277 | None | Common PWD SR 23-24 V-6 pg no 4 item no 1.13 | Supplying and Fixing Metal Fan Box with Round Hook. | Each | 138.06 | 138.06 | 12.0 | False | None | None | False | None | False | 1656.72 | 0 | 3503661 | 125277 | None | Common PWD SR 23-24 V-6 pg no 2 item no 1.2.1 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2). 19/20mm dia 2mm thick | m | 77.88 | 77.88 | 165.0 | False | None | None | False | None | False | 12850.2 | 0 | 3503662 | 125277 | None | Common PWD SR 23-24 V-6 pg no 2 item no 1.2.2 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2).25mm dia 2mm thick | m | 92.04 | 92.04 | 120.0 | False | None | None | False | None | False | 11044.8 | 0 | 3503663 | 125277 | None | Common PWD SR 23-24 V-6 pg no 2 item no 1.3.1 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.19/20mm dia 2mm thick | m | 80.24 | 80.24 | 165.0 | False | None | None | False | None | False | 13239.6 | 0 | 3503664 | 125277 | None | Common PWD SR 23-24 V-6 pg no 2 item no 1.3.2 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.25mm dia 2mm thick | m | 93.22 | 93.22 | 120.0 | False | None | None | False | None | False | 11186.4 | 0 | 3503665 | 125277 | None | Common PWD SR 23-24 V-6 pg no 5 item no 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latestamendments.1.5 sqmm | m | 30.68 | 30.68 | 350.0 | False | None | None | False | None | False | 10738.0 | 0 | 3503666 | 125277 | None | Common PWD SR 23-24 V-6 pg no 5 item no 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latestamendments. 2.5 sqmm | m | 49.56 | 49.56 | 450.0 | False | None | None | False | None | False | 22302.0 | 0 | 3503667 | 125277 | None | Common PWD SR 23-24 V-6 pg no 5 item no 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latestamendments. 4 sqmm | m | 74.34 | 74.34 | 190.0 | False | None | None | False | None | False | 14124.6 | 0 | 3503668 | 125277 | None | Common PWD SR 23-24 V-6 pg no 18 item no 5.19.9 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure.II - Double Door12 Way SP & N | Each | 2748.22 | 2748.22 | 2.0 | False | None | None | False | None | False | 5496.44 | 0 | 3503669 | 125277 | None | Common PWD SR 23-24 V-6 pg no 17 item no 5.18.1 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32Amps SP | Each | 489.7 | 489.7 | 12.0 | False | None | None | False | None | False | 5876.4 | 0 | 3503670 | 125277 | None | Common PWD SR 23-24 V-6 pg no 18 item no 5.20.1 | Supplying,fixingandwiringResidualcurrentcircuitbreaker(RCCB)240/450V upto 300mA sensitivity on existing wood/ panel board. Board. 16-25 Amps 2 pole | Each | 5046.86 | 5046.86 | 2.0 | False | None | None | False | None | False | 10093.72 | 0 | 3503671 | 125277 | None | Common PWD SR 23-24 V-6 pg no 43 item no 11.3.2 | Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fighting 1 x4'- 20/22 w | Each | 814.2 | 814.2 | 15.0 | False | None | None | False | None | False | 12213.0 | 0 | 3503672 | 125277 | None | Common PWD SR 23-24 V-6 pg no 47 item no 11.11.3 | Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per watt, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K | Each | 175.82 | 175.82 | 4.0 | False | None | None | False | None | False | 703.28 | 0 | 3503673 | 125277 | None | Common PWD SR 23-24 V-6 pg no 47 item no 11.11.7 | Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per watt, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.18 W, 6500K | Each | 502.68 | 502.68 | 6.0 | False | None | None | False | None | False | 3016.08 | 0 | 3503674 | 125277 | None | Common PWD SR 23-24 V-6 pg no 50 item no 12.27 | Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply | No | 61.36 | 61.36 | 2.0 | False | None | None | False | None | False | 122.72 | 0 | 3503675 | 125277 | None | Common PWD SR 23-24 V-6 pg no 30 item no 6.1 | Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. | Each | 1760.56 | 1760.56 | 4.0 | False | None | None | False | None | False | 7042.24 | 0 | 3503676 | 125277 | None | Common PWD SR 23-24 V-6 pg no 30 item no 6.3.1 | Supplying capacitor type ceiling fan complete with down rodblades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model | Each | 3521.12 | 3521.12 | 12.0 | False | None | None | False | None | False | 42253.44 | 0 | 3503677 | 125277 | None | Common PWD SR 23-24 V-6 pg no 52 item no 12.46 | Supplying & Fixing of 70-150 Watts lamp holder 2 Pin | Each | 74.34 | 74.34 | 22.0 | False | None | None | False | None | False | 1635.48 | 0 | 3503678 | 125277 | None | Common PWD SR 23-24 V-6 pg no 56 item no 13.7.1 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders | Each | 143.96 | 143.96 | 28.0 | False | None | None | False | None | False | 4030.88 | 0 | 3503679 | 125277 | None | Common PWD SR 23-24 V-6 pg no 57 item no 13.11 | Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. | Each | 371.7 | 371.7 | 12.0 | False | None | None | False | None | False | 4460.4 | 0 | 3503680 | 125277 | None | Common PWD SR 23-24 V-6 pg no 57 item no 13.13 | Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. | Each | 834.26 | 834.26 | 3.0 | False | None | None | False | None | False | 2502.78 | 0 | 3503681 | 125277 | None | Common PWD SR 23-24 V-6 pg no 56 item no 13.4.1 | Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length | Each | 1723.98 | 1723.98 | 2.0 | False | None | None | False | None | False | 3447.96 | 0 | 3503682 | 125277 | None | Common PWD SR 23-24 V-6 pg no 13 item no 32.07 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 3.5 core 25 sqmm ( 12 GI Strips -4 X 0.8 mm) | Km | 164667.82 | 164667.82 | 0.065 | False | None | None | False | None | False | 10703.4083 | 0 | 3503683 | 125277 | None | Common PWD SR 23-24 V-6 pg no 52 item no 21.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff | Km | 24645.48 | 24645.48 | 0.065 | False | None | None | False | None | False | 1601.9562 | 0 | 3503684 | 125277 | None | 19-20 SR item no 6.11.3 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 19-20 SR | Each | 143.96 | 143.96 | 10.0 | False | None | None | False | None | False | 1439.6 | 0 | 3503685 | 125277 | None | 19-20 SR item no 6.17.5 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes .10 sqmm | Each | 9.44 | 9.44 | 8.0 | False | None | None | False | None | False | 75.52 | 0 | 3503686 | 125277 | None | 21-22 SR BSR item no 29.03 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr,Supplying and Displaying necessary Danger Boards and Lighting, Using sightRails and Sign Boards at every 100 Mtr wherever necessary as directed-In ordinary soil | cm | 306.8 | 306.8 | 30.0 | False | None | None | False | None | False | 9204.0 | 0 | 3503687 | 125277 | None | Common PWD SR 23-24 V-6 pg no 20 item no 5.42.1 | Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete.14SWG | Sq CM | 0.59 | 0.59 | 60000.0 | False | None | None | False | None | False | 35400.0 | 0 | 3503688 | 125277 | None | Common PWD SR 23-24 V-6 pg no 20 item no 5.40.3 | Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolici FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.400 A 4 x 50 x 10 mm Aluminium Strips | m | 5245.1 | 5245.1 | 1.5 | False | None | None | False | None | False | 7867.65 | 0 | 3503689 | 125277 | None | Common PWD SR 23-24 V-6 pg no 20 item no 5.41.3 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint.75x75x6mm | m | 654.9 | 654.9 | 5.0 | False | None | None | False | None | False | 3274.5 | 0 | 3503690 | 125277 | None | Common PWD SR 23-24 V-6 pg no 56 item no 13.5 | Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. | Each | 191.16 | 191.16 | 2.0 | False | None | None | False | None | False | 382.32 | 0 | 3503691 | 125277 | None | Common PWD SR 23-24 V-6 pg no 20 item no 5.40.1 | Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips | m | 2908.7 | 2908.7 | 2.0 | False | None | None | False | None | False | 5817.4 | 0 | 3503692 | 125277 | None | Common PWD SR 23-24 V-6 pg no 20 item no 5.41.4 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel | m | 892.08 | 892.08 | 2.0 | False | None | None | False | None | False | 1784.16 | 0 | 3503693 | 125277 | None | Common PWD SR 23-24 V-6 pg no 17 item no 5.18.4 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DP | Each | 872.02 | 872.02 | 3.0 | False | None | None | False | None | False | 2616.06 | 0 | 3503694 | 125277 | None | Common PWD SR 23-24 V-6 pg no 18 item no 5.18.9 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN | Each | 3643.84 | 3643.84 | 1.0 | False | None | None | False | None | False | 3643.84 | 0 | 3503695 | 125277 | None | Common PWD SR 23-24 V-6 pg no 14 item no 5.7.2 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers 32Amps | Each | 284.38 | 284.38 | 3.0 | False | None | None | False | None | False | 853.14 | 0 | 3503696 | 125277 | None | Common PWD SR 23-24 V-6 pg no 14 item no 5.7.3 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers 63Amps | Each | 473.18 | 473.18 | 1.0 | False | None | None | False | None | False | 473.18 | 0 | 3503697 | 125277 | None | Common PWD SR 23-24 V-6 pg no 15 item no 5.12.1 | Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution)63Amps | Each | 8119.58 | 8119.58 | 1.0 | False | None | None | False | None | False | 8119.58 | 0 | 3503698 | 125277 | None | Common PWD SR 23-24 V-6 pg no 19 item no 5.27 | Supplying, fixing and wiring rotary selector switch suitable for Ammeter | Each | 236.0 | 236.0 | 1.0 | False | None | None | False | None | False | 236.0 | 0 | 3503699 | 125277 | None | Common PWD SR 23-24 V-6 pg no 19 item no 5.28 | Supplying, fixing and wiring rotary selector switch suitable for Voltmeter | Each | 188.8 | 188.8 | 1.0 | False | None | None | False | None | False | 188.8 | 0 | 3503700 | 125277 | None | Common PWD SR 23-24 V-6 pg no 19 item no 5.29 | Supplying, fixing and wiring 3 Phase Digital Ammeter | Each | 1681.5 | 1681.5 | 2.0 | False | None | None | False | None | False | 3363.0 | 0 | 3503701 | 125277 | None | Common PWD SR 23-24 V-6 pg no 19 item no 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C | Each | 607.7 | 607.7 | 2.0 | False | None | None | False | None | False | 1215.4 | 0 | 3503702 | 125277 | None | Common PWD SR 23-24 V-6 pg no 19 item no 5.34 | Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound (48/6.32) | Each | 663.16 | 663.16 | 3.0 | False | None | None | False | None | False | 1989.48 | 0 | 3503703 | 125277 | None | Common PWD SR 23-24 V-6 pg no 19 item no 5.3 | Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter | Each | 1628.4 | 1628.4 | 2.0 | False | None | None | False | None | False | 3256.8 | 0 |
|
|
---|