createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1720773668170
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyRESERVED
invitingStrategyTextReserved
taxTypeINCLUSIVE_TAX
tenderFee1630.00
emd65000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose23-07-2024 16:00:00
tenderQueryClose20-07-2024 16:00:00
technicalBidOpen24-07-2024 16:30:00
publishedDate15-07-2024 17:27:43
publishedByPostEWHFWD_EE_EEOFF_DWD
publishedByUserKPE13493 - SURESH S N
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonM M Kattimani
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08362955800
mobileNumber9740775411
tenderSupplierListNone
tenderSchedule
createdTs1720773668197
version6
createdDateNone
modifiedDateNone
tenderNumberEWHFWD/2024-25/BD/WORK_INDENT479
titleConstruction of Health and Wellness Center at Albal in Jamkhandi Taluk, Bagalkote District.
descriptionConstruction of Health and Wellness Center at Albal in Jamkhandi Taluk, Bagalkote District.
categoryWORKS
categoryTextWorks
ecv6493899.92
deptNameEngineering Wing of Health and Family Welfare Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3524
locationNameEWHFWD Executive Engineer Office Dharwad
provisionalAmount6500000.0
groupOverheadTotalNone
fileNumberaee/hfwd/sd/vjp/Albal/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17207736680000NoneNoneBuildingsConstruction of Health and Wellness Center at Albal in Jamkhandi Taluk, Bagalkote District. (GF Civil Wrok)3787007.71
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3514495126033None2.5iiAV3Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer. In area of light jungle. (for GF)100 Sqm477.65477.652.16FalseNoneNoneFalseNoneFalse1031.7240
3514496126033None1.12V1Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth. (for GF)Cum115.46115.4643.2FalseNoneNoneFalseNoneFalse4987.8720
3514497126033None1.14.1V1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m. (for GF)Cum123.97123.97140.05FalseNoneNoneFalseNoneFalse17361.99850
3514498126033None1.15.1V1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth. (for GF)Cum441.19441.19161.16FalseNoneNoneFalseNoneFalse71102.18040
3514499126033None2.1.4V1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates. (for GF)Cum7556.147556.1433.39FalseNoneNoneFalseNoneFalse252299.51460
3514500126033None2.2.3V1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including FormWork. (for GF Footing) (for GF)Cum8316.848316.8429.07FalseNoneNoneFalseNoneFalse241770.53880
3514501126033None2.2.3V1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (for GF PEDESTALS)Cum8470.858470.851.67FalseNoneNoneFalseNoneFalse14146.31950
3514502126033None2.2.3V1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ((for GF PLINTH BEAM)Cum11551.1611551.1619.96FalseNoneNoneFalseNoneFalse230561.15360
3514503126033None2.5.2V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. (for GF COLUMNS)Cum14138.8714138.879.42FalseNoneNoneFalseNoneFalse133188.15540
3514504126033None2.5.2V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. (for GF RCC BEAMS & LINTELS)Cum13307.1713307.1714.73FalseNoneNoneFalseNoneFalse196014.61410
3514505126033None2.5.2V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. (for GF RCC SLAB & RCC STAIRCASE)Cum12475.4712475.4710.85FalseNoneNoneFalseNoneFalse135358.84950
3514506126033None2.5.2V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. (for GF RCC For Chajja)Cum12059.6212059.620.39FalseNoneNoneFalseNoneFalse4703.25180
3514507126033None1.9V1Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (for GF)Cum323.3323.3227.07FalseNoneNoneFalseNoneFalse73411.7310
3514508126033None2.11aV1Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire/soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings. (for GF)Tonne108726.04108726.046.09FalseNoneNoneFalseNoneFalse662141.58360
3514509126033None5.1.1V2Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) (for GF)Cum6819.616819.618.06FalseNoneNoneFalseNoneFalse54966.05660
3514510126033None6.8V2Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (for GF)Cum9685.529685.5239.87FalseNoneNoneFalseNoneFalse386161.68240
3514511126033None6.15V2Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (for GF)Sqm1255.511255.5143.65FalseNoneNoneFalseNoneFalse54803.01150
3514512126033None12.13.1V2Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (for GF)Cum120099.75120099.750.41FalseNoneNoneFalseNoneFalse49240.89750
3514513126033None12.51V2Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. (for GF)Nos1234.851234.856.0FalseNoneNoneFalseNoneFalse7409.10
3514514126033NoneData RateProviding and fixing Aluminium fixtures like Aldrops of size 300 x 16 mm, Tower bolts of size 200 x 12 mm, Latches of size 250 x12 mm, 100 mm length oxidized Iron Hinges, Handles of size 150 mm, Door Stopper & Door Bush of approved make and quality including cost and conveyance of all materials and as per the direction of EIC of work with all lead and lift and as directed by the Engineer in charge of works. Single Shutter. (Locking Arrangements) (for GF)Nos5226.225226.226.0FalseNoneNoneFalseNoneFalse31357.320
3514515126033None10.6.3V2Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm. (for GF)Nos72.9272.9236.0FalseNoneNoneFalseNoneFalse2625.120
3514516126033None12.57.5V2Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick one side teak and one side commercial. (for GF)Sqm4736.414736.4116.8FalseNoneNoneFalseNoneFalse79571.6880
3514517126033None11.44V2Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (for GF)Sqm5280.915280.9112.12FalseNoneNoneFalseNoneFalse64004.62920
3514518126033None11.34BV2Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. (for GF)Kg204.19204.19254.52FalseNoneNoneFalseNoneFalse51970.43880
3514519126033None12.54V2Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. (for GF)m386.5386.519.8FalseNoneNoneFalseNoneFalse7652.70
3514520126033None12.53V2Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm Aluminium hinges. (for GF)Sqm1930.061930.066.3FalseNoneNoneFalseNoneFalse12159.3780
3514521126033None8.10V2Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (ceiling) (for GF)Sqm256.45256.45119.52FalseNoneNoneFalseNoneFalse30650.9040
3514522126033None8.5.2V2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Inside) (for GF)Sqm424.17424.17335.18FalseNoneNoneFalseNoneFalse142173.30060
3514523126033None8.51V2Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (for GF)Sqm121.54121.54391.78FalseNoneNoneFalseNoneFalse47616.94120
3514524126033None8.8V2Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (outside) (for GF)Sqm450.91450.91172.92FalseNoneNoneFalseNoneFalse77971.35720
3514525126033None8.2.1V2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (for GF)Sqm358.54358.5438.41FalseNoneNoneFalseNoneFalse13771.52140
3514526126033None15.1V2Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU wa terproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. (for GF)Sqm992.98992.9812.24FalseNoneNoneFalseNoneFalse12154.07520
3514527126033None9.21.2V2Providing and laying Vitrified tiles with thickness 9-10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm. (for GF)Sqm1504.671504.6772.88FalseNoneNoneFalseNoneFalse109660.34960
3514528126033None9.23V2Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rub bing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent. (for GF)Sqm2997.182997.1840.53FalseNoneNoneFalseNoneFalse121475.70540
3514529126033None9.11V2Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. (for GF)Sqm1080.491080.4913.06FalseNoneNoneFalseNoneFalse14111.19940
3514530126033None9.38V2Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (for GF)Sqm1691.841691.8438.41FalseNoneNoneFalseNoneFalse64983.57440
3514531126033None9.36V2Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. (for GF)Sqm2005.412005.415.65FalseNoneNoneFalseNoneFalse11330.56650
3514532126033None9.29V2Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. (for GF)Sqm5233.515233.519.84FalseNoneNoneFalseNoneFalse51497.73840
3514533126033None11.28V2Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (for GF)Kg686.7686.743.2FalseNoneNoneFalseNoneFalse29665.440
3514534126033None8.39V2Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (for GF)Sqm154.36154.36479.32FalseNoneNoneFalseNoneFalse73987.83520
3514535126033None8.30V2Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (for GF)Sqm211.48211.48172.92FalseNoneNoneFalseNoneFalse36569.12160
3514536126033None8.34.3V2Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (for GF)Sqm60.7760.7712.12FalseNoneNoneFalseNoneFalse736.53240
3514537126033None8.40V2Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (for GF)Sqm139.77139.7712.12FalseNoneNoneFalseNoneFalse1694.01240
3514538126033None8.55.1V2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge. (for GF)Sqm68.0668.0620.74FalseNoneNoneFalseNoneFalse1411.56440
3514539126033None8.68V2Polishing on wood work with readymade wax polish of approved brand and manufacture : Old work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (for GF)Sqm82.6582.6520.74FalseNoneNoneFalseNoneFalse1714.1610
3514540126033None12.62V2Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete.(for GF)No288.05288.0524.0FalseNoneNoneFalseNoneFalse6913.20
3514541126033None12.58V2Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. (for GF)No145.85145.8512.0FalseNoneNoneFalseNoneFalse1750.20
3514542126033None12.60V2Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. (for GF)No1278.61278.624.0FalseNoneNoneFalseNoneFalse30686.40
3514543126033None12.63V2Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete. (for GF)No158.0158.024.0FalseNoneNoneFalseNoneFalse3792.00
3514544126033None804V2Providing and fixing SS Screws of sizes for structural glazing /ACP Cladding. (for GF)No2.432.43650.0FalseNoneNoneFalseNoneFalse1579.50
3514545126033None8.16.2V2Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment. Plaster mesh 150mm wide. (for GF)m46.1946.19308.92FalseNoneNoneFalseNoneFalse14269.01480
3514546126033NoneData RatePreparation of detailed Structural designs and drawings including Soil exploration & proof checking and Providing consultancy for Architectural design and drawings floor wise. , 3D view, MFP design and drawings. Electrical services,HVAC Lift, RO plant, Medical gas pipe line with manifold room, interior layout and Providing consultancy services for water supply & sanitary, electrical drawings & any other related drawings to this work and liaison with other department and approval of pollution control board and allied works etc., ---- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. (for GF)Job44840.044840.01.0FalseNoneNoneFalseNoneFalse44840.00
17207736680000NoneNoneBuildingsConstruction of Health and Wellness Center at Albal in Jamkhandi Taluk, Bagalkote District. (FF Civil Wrok)1789626.14
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3514547126034None2.5.2V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. (for FF COLUMNS)Cum14280.2614280.264.33FalseNoneNoneFalseNoneFalse61833.52580
3514548126034None2.5.2V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. (for FF RCC BEAMS & LINTELS)Cum13440.2413440.2410.26FalseNoneNoneFalseNoneFalse137896.86240
3514549126034None2.5.2V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. (for FF RCC SLAB)Cum12600.2312600.236.82FalseNoneNoneFalseNoneFalse85933.56860
3514550126034None2.5.2V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. (for FF Chejja)Cum12180.2212180.220.42FalseNoneNoneFalseNoneFalse5115.69240
3514551126034None2.1.4V1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregatesCum7631.77631.71.38FalseNoneNoneFalseNoneFalse10531.7460
3514552126034None2.11aV1Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire/soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. BuildingsTonne109813.3109813.31.53FalseNoneNoneFalseNoneFalse168014.3490
3514553126034None6.8V2Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum9782.389782.3836.41FalseNoneNoneFalseNoneFalse356176.45580
3514554126034None6.15V2Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Sqm1268.061268.0653.77FalseNoneNoneFalseNoneFalse68183.58620
3514555126034None12.13.1V2Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specificationsCum121300.75121300.750.21FalseNoneNoneFalseNoneFalse25473.15750
3514556126034None12.51V2Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.No1247.191247.194.0FalseNoneNoneFalseNoneFalse4988.760
3514557126034NoneData RateProviding and fixing Aluminium fixtures like Aldrops of size 300 x 16 mm, Tower bolts of size 200 x 12 mm, Latches of size 250 x12 mm, 100 mm length oxidized Iron Hinges, Handles of size 150 mm, Door Stopper & Door Bush of approved make and quality including cost and conveyance of all materials and as per the direction of EIC of work with all lead and lift and as directed by the Engineer in charge of works. Single Shutter. (Locking Arrangements)Nos5278.485278.484.0FalseNoneNoneFalseNoneFalse21113.920
3514558126034None10.6.3V2Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmNos73.6573.6524.0FalseNoneNoneFalseNoneFalse1767.60
3514559126034None12.57.5V2Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick one side teak and one side commercialSqm4783.784783.789.12FalseNoneNoneFalseNoneFalse43628.07360
3514560126034None11.44V2Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm5333.725333.7210.32FalseNoneNoneFalseNoneFalse55043.99040
3514561126034None11.34B V2Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingKg206.23206.23216.72FalseNoneNoneFalseNoneFalse44694.16560
3514562126034None12.54V2Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.m390.36390.369.9FalseNoneNoneFalseNoneFalse3864.5640
3514563126034None12.53V2Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm Aluminium hinges.Sqm1949.361949.363.15FalseNoneNoneFalseNoneFalse6140.4840
3514564126034None8.5.2V2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Inside)Sqm428.42428.42252.34FalseNoneNoneFalseNoneFalse108107.50280
3514565126034None8.51V2Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in chargeSqm122.76122.76321.05FalseNoneNoneFalseNoneFalse39412.0980
3514566126034None8.8V2Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (outside)Sqm455.42455.42212.51FalseNoneNoneFalseNoneFalse96781.30420
3514567126034None8.2.1V2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm362.13362.1327.87FalseNoneNoneFalseNoneFalse10092.56310
3514568126034None7.18V2Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.Cum2475.982475.981.2FalseNoneNoneFalseNoneFalse2971.1760
3514569126034None15.1V2Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU wa terproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the wa terproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.Sqm1002.911002.91109.54FalseNoneNoneFalseNoneFalse109858.76140
3514570126034None9.21.2V2Providing and laying Vitrified tiles with thickness 9-10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mmSqm1519.711519.7155.67FalseNoneNoneFalseNoneFalse84602.25570
3514571126034None9.11V2Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.Sqm1091.31091.35.98FalseNoneNoneFalseNoneFalse6525.9740
3514572126034None9.38V2Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.Sqm1708.761708.7627.87FalseNoneNoneFalseNoneFalse47623.14120
3514573126034None9.36V2Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications.Sqm2025.462025.465.65FalseNoneNoneFalseNoneFalse11443.8490
3514574126034None9.29V2Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.Sqm5285.855285.859.8FalseNoneNoneFalseNoneFalse51801.330
3514575126034None8.39V2Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm155.9155.9396.48FalseNoneNoneFalseNoneFalse61811.2320
3514576126034None8.30V2Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm213.59213.59212.51FalseNoneNoneFalseNoneFalse45390.01090
3514577126034None8.29V2Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm347.4347.421.25FalseNoneNoneFalseNoneFalse7382.250
3514578126034None8.34.3V2Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm61.3861.3810.32FalseNoneNoneFalseNoneFalse633.44160
3514579126034None8.40V2Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm141.17141.1710.32FalseNoneNoneFalseNoneFalse1456.87440
3514580126034None8.55.1V2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge.Sqm68.7468.7421.89FalseNoneNoneFalseNoneFalse1504.71860
3514581126034None8.68V2Polishing on wood work with readymade wax polish of approved brand and manufacture : Old work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm83.4783.4721.89FalseNoneNoneFalseNoneFalse1827.15830
17207736680000NoneNoneBuildingsConstruction of Health and Wellness Center at Albal in Jamkhandi Taluk, Bagalkote District. (WS Wrok)366763.82
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3514582126035None14.3.1V2Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lidEach6083.086083.082.0FalseNoneNoneFalseNoneFalse12166.160
3514583126035None14.1.1V2Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot restsEach5936.015936.013.0FalseNoneNoneFalseNoneFalse17808.030
3514584126035None14.7.1V2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous hina Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar tapsEach3745.863745.866.0FalseNoneNoneFalseNoneFalse22475.160
3514585126035None14.22AV2Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer in-charge.Each984.47984.4712.0FalseNoneNoneFalseNoneFalse11813.640
3514586126035None14.22BV2Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.Each6760.056760.051.0FalseNoneNoneFalseNoneFalse6760.050
3514587126035None14.10.1.2V2Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 510x1040 mm bowl depth 225 mmEach6554.656554.651.0FalseNoneNoneFalseNoneFalse6554.650
3514588126035None14.29V2Providing and fixing 100 mm sand cast Iron grating for gully trap.Each57.1257.125.0FalseNoneNoneFalseNoneFalse285.60
3514589126035None13.59V2Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories completeEach275.18275.186.0FalseNoneNoneFalseNoneFalse1651.080
3514590126035None14.36.2V2Providing and fixing PTMT Waste Coupling for wash basin and sink, of pproved quality and colour. Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gEach113.03113.035.0FalseNoneNoneFalseNoneFalse565.150
3514591126035None14.40.1V2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 g.Each580.96580.965.0FalseNoneNoneFalseNoneFalse2904.80
3514592126035None13.25V2Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gmsNo177.45177.452.0FalseNoneNoneFalseNoneFalse354.90
3514593126035None10.1.3V2Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc., complete For: PVC pipes 50mm dia., 6 kg/sqcm & class 5m126.33126.3325.0FalseNoneNoneFalseNoneFalse3158.250
3514594126035None10.1.5V2Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc., complete For: PVC pipes 75mm dia., 6 kg/sqcm & class 5m275.18275.1825.0FalseNoneNoneFalseNoneFalse6879.50
3514595126035None10.1.7V2Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc., complete For: PVC pipes 110mm dia., 6 kg/sqcm & class 5m514.08514.0870.0FalseNoneNoneFalseNoneFalse35985.60
3514596126035None13.32.1V2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia pipesm375.56375.5645.0FalseNoneNoneFalseNoneFalse16900.20
3514597126035None13.32.2V2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipesm460.64460.6490.0FalseNoneNoneFalseNoneFalse41457.60
3514598126035None13.32.3V2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipesm579.75579.7520.0FalseNoneNoneFalseNoneFalse11595.00
3514599126035None13.34V2Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.l10.9410.942000.0FalseNoneNoneFalseNoneFalse21880.00
3514600126035None7.4.2V6Supplying, installation, testing and commissioning of solar hot water heater comprising of high quality Evacuated Glass Tube (EGT) with absorber coating collector of size 58 x 1800 mm. Inner tank Material Stainless steel 304-L Grade with Aluminium Stucco cladding made of High quality PUF insulation to minimizes heat loss and hold water Temperature upto 72 Hrs...with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. Fitted with Sacrificial Anode. 200 L- 20 nos TubesEach52532.0252532.021.0FalseNoneNoneFalseNoneFalse52532.020
3514601126035None13.54V2Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 500X700 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets :With common burnt clay (non modular) bricks of class designation 3.5Each7630.287630.282.0FalseNoneNoneFalseNoneFalse15260.560
3514602126035None11.16.3V2Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeKg148.28148.28120.0FalseNoneNoneFalseNoneFalse17793.60
3514603126035None13.33.2V2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. External & Shafts & Terrace. 20 mm nominal dia Pipesm263.74263.7430.0FalseNoneNoneFalseNoneFalse7912.20
3514604126035None13.33.3V2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. External & Shafts & Terrace. 25 mm nominal dia Pipesm359.76359.7640.0FalseNoneNoneFalseNoneFalse14390.40
3514605126035None14.11.2V2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mmNos6176.666176.661.0FalseNoneNoneFalseNoneFalse6176.660
3514606126035None14.31V2Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.Each1482.781482.785.0FalseNoneNoneFalseNoneFalse7413.90
3514607126035None13.47V2Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 75 mm diameterm239.43239.4330.0FalseNoneNoneFalseNoneFalse7182.90
3514608126035None13.7.1V5Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc. complete 1.50 HP/1.1KW. 7 STGEach16906.2116906.211.0FalseNoneNoneFalseNoneFalse16906.210
17207736680000NoneNoneBuildingsConstruction of Health and Wellness Center at Albal in Jamkhandi Taluk, Bagalkote District. (Electrical Wrok)358274.69
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3514609126036None2.2.1V6SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingcasingcappingusing2x1.5Sqmm(Phase&Neutral) &1x1.0 sqmm(Earthwire)FRLSmulti strandPVCinsulated copperwire(confirmingtoIS-694: andlatest amendments)without control switchshallbefixedontheexistingplasticsheet/gangbox, theother endof thewires shall be terminatedwith sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxPoint326.94326.9435.0FalseNoneNoneFalseNoneFalse11442.90
3514610126036None2.2.2V6SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingcasingcappingusing2x1.5Sqmm(Phase&Neutral) &1x1.0 sqmm(Earthwire)FRLSmulti strandPVCinsulated copperwire(confirmingtoIS-694: andlatest amendments)without control switchshallbefixedontheexistingplasticsheet/gangbox, theother endof thewires shall be terminatedwith sufficient loose length in a wood/PVC round block. complete for each outlet. Mediumpointabove3Mtrupto6Mtrfromtappingpoint toout letvia switch boxPoint460.64460.6425.0FalseNoneNoneFalseNoneFalse11516.00
3514611126036None2.2.3V6SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingcasingcappingusing2x1.5Sqmm(Phase&Neutral) &1x1.0 sqmm(Earthwire)FRLSmulti strandPVCinsulated copperwire(confirmingtoIS-694: andlatest amendments)without control switchshallbefixedontheexistingplasticsheet/gangbox, theother endof thewires shall be terminatedwith sufficient loose length in a wood/PVC round block. complete for each outlet. Longpoint above6Mtrupto10Mtr fromtappingpoint toout letvia switch boxPoint674.55674.5520.0FalseNoneNoneFalseNoneFalse13491.00
3514612126036None3.4.1V6Supplyingandflushmountingpowdercoated/galvanizedmetalboxsuitableformountingmodularswitchplates.Theboxshouldbefirmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 1-2 WayEach167.73167.7315.0FalseNoneNoneFalseNoneFalse2515.950
3514613126036None3.4.2V6Supplyingandflushmountingpowdercoated/galvanizedmetalboxsuitableformountingmodularswitchplates.Theboxshouldbefirmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 3 WayEach193.25193.258.0FalseNoneNoneFalseNoneFalse1546.00
3514614126036None3.4.3V6Supplyingandflushmountingpowdercoated/galvanizedmetalboxsuitableformountingmodularswitchplates.Theboxshouldbefirmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 4-5 WayEach215.13215.134.0FalseNoneNoneFalseNoneFalse860.520
3514615126036None3.4.4V6Supplyingandflushmountingpowdercoated/galvanizedmetalboxsuitableformountingmodularswitchplates.Theboxshouldbefirmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 6 WayEach267.39267.3910.0FalseNoneNoneFalseNoneFalse2673.90
3514616126036None3.4.5V6Supplyingandflushmountingpowdercoated/galvanizedmetalboxsuitableformountingmodularswitchplates.Theboxshouldbefirmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 8 WayEach317.22317.226.0FalseNoneNoneFalseNoneFalse1903.320
3514617126036None3.5.1V6Supplying and fixing superior quality modular switch mounting polycarbonateplatewithnecessarysupportingbackplatewithrequired nos. ofmachine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 ModuleEach166.51166.5115.0FalseNoneNoneFalseNoneFalse2497.650
3514618126036None3.5.2V6Supplying and fixing superior quality modular switch mounting polycarbonateplatewithnecessarysupportingbackplatewithrequired nos. ofmachine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 ModuleEach195.68195.688.0FalseNoneNoneFalseNoneFalse1565.440
3514619126036None3.5.3V6Supplying and fixing superior quality modular switch mounting polycarbonateplatewithnecessarysupportingbackplatewithrequired nos. ofmachine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 ModuleEach212.7212.74.0FalseNoneNoneFalseNoneFalse850.80
3514620126036None3.5.4V6Supplying and fixing superior quality modular switch mounting polycarbonateplatewithnecessarysupportingbackplatewithrequired nos. ofmachine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 ModuleEach284.4284.410.0FalseNoneNoneFalseNoneFalse2844.00
3514621126036None3.5.5V6Supplying and fixing superior quality modular switch mounting polycarbonateplatewithnecessarysupportingbackplatewithrequired nos. ofmachine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 ModuleEach345.17345.176.0FalseNoneNoneFalseNoneFalse2071.020
3514622126036None3.6.1V6Supplyingandfixingofmodular switch&connectedaccessorieson existing modular switch plate as per IS 3854 and IS 1293. 6A One Way SwitchEach123.97123.9740.0FalseNoneNoneFalseNoneFalse4958.80
3514623126036None3.6.2V6Supplyingandfixingofmodular switch&connectedaccessorieson existing modular switch plate as per IS 3854 and IS 1293. 6A Two Way SwitchEach201.76201.768.0FalseNoneNoneFalseNoneFalse1614.080
3514624126036None3.6.3V6Supplyingandfixingofmodular switch&connectedaccessorieson existing modular switch plate as per IS 3854 and IS 1293. 6A Three Way socketEach207.83207.8330.0FalseNoneNoneFalseNoneFalse6234.90
3514625126036None3.6.8V6Supplyingandfixingofmodular switch&connectedaccessorieson existing modular switch plate as per IS 3854 and IS 1293. 6A Bell PushEach215.13215.133.0FalseNoneNoneFalseNoneFalse645.390
3514626126036None3.6.4V6Supplyingandfixingofmodular switch&connectedaccessorieson existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two ModuleEach433.9433.912.0FalseNoneNoneFalseNoneFalse5206.80
3514627126036None3.6.9V6Supplyingandfixingofmodular switch&connectedaccessorieson existing modular switch plate as per IS 3854 and IS 1293. 32A DP SwitchEach396.22396.2211.0FalseNoneNoneFalseNoneFalse4358.420
3514628126036None3.6.10V6Supplyingandfixingofmodular switch&connectedaccessorieson existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal SocketEach286.83286.8311.0FalseNoneNoneFalseNoneFalse3155.130
3514629126036None3.6.11V6Supplyingandfixingofmodular switch&connectedaccessorieson existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone SocketEach189.6189.66.0FalseNoneNoneFalseNoneFalse1137.60
3514630126036None12.2.1V6Supplyingandfixingoneof230VDingdongbellandaflushtypebell pushwithgangboxfixedonnecessarywoodenorrawlplugsusingNF screws with Remote. Ding Dong BellEach298.99298.993.0FalseNoneNoneFalseNoneFalse896.970
3514631126036None1.13V6SSupplying And Fixing Metal Fan Box with Round Hook.No142.2142.212.0FalseNoneNoneFalseNoneFalse1706.40
3514632126036None1.2.1V6Supplying heavygaugePVCconduitpipe......mmdia..........mmthick confirming toIS2509withsuitablesizebends,metal/PVCJunction boxes, adhesivepasteetc.,andrunningbeforeconcretingtheslab. The conduit shouldbe tied to the reinforcement rods byusingbinding wiresandunusedwaysof junction boxesandpipeends should be covered usingPVCendenclosures, runwith18SWGGI fishwire wherever necessary 19/20 mm dia 2 mm thickm80.2280.22120.0FalseNoneNoneFalseNoneFalse9626.40
3514633126036None1.2.2V6Supplying heavygaugePVCconduitpipe......mmdia..........mmthick confirming toIS2509withsuitablesizebends,metal/PVCJunction boxes, adhesivepasteetc.,andrunningbeforeconcretingtheslab. The conduit shouldbe tied to the reinforcement rods byusingbinding wiresandunusedwaysof junction boxesandpipeends should be covered usingPVCendenclosures, runwith18SWGGI fishwire wherever necessary 25 mm dia 2 mm thickm94.894.8100.0FalseNoneNoneFalseNoneFalse9480.00
3514634126036None1.3.1V6Supplying heavy gauge PVCConduit Pipe .... dia .......mmthick withsuitablesizebends,metal junctionboxesadhesivepasteetc.,by groovecuttinginthewall andfixing bybracingUor Jhooks and cementplasteringuptothewallsurfaceandrunwith18SWGGIfish wire run throughout the conduit wherever necessary. 19/20 mm dia 2 mm thickm82.6582.6580.0FalseNoneNoneFalseNoneFalse6612.00
3514635126036None1.3.2V6Supplying heavy gauge PVCConduit Pipe .... dia .......mmthick withsuitablesizebends,metal junctionboxesadhesivepasteetc.,by groovecuttinginthewall andfixing bybracingUor Jhooks and cementplasteringuptothewallsurfaceandrunwith18SWGGIfish wire run throughout the conduit wherever necessary. 25 mm dia 2 mm thickm96.0296.0260.0FalseNoneNoneFalseNoneFalse5761.20
3514636126036None2.3.2V6Wiringfor lighting/powercircuitusingoneof FRLSPVCinsulated 1100Vgrade,multistrandcopperwirewithlowconductor resistance singlecore inopenorconcealedsystemofwiringwithspecifiedIS 694:2010 1.5 mm2Mtr31.631.6135.0FalseNoneNoneFalseNoneFalse4266.00
3514637126036None2.3.3V6Wiringfor lighting/powercircuitusingoneof FRLSPVCinsulated 1100Vgrade,multistrandcopperwirewithlowconductor resistance singlecore inopenorconcealedsystemofwiringwithspecifiedIS 694:2010 2.5 mm2Mtr51.0551.05200.0FalseNoneNoneFalseNoneFalse10210.00
3514638126036None2.3.4V6Wiringfor lighting/powercircuitusingoneof FRLSPVCinsulated 1100Vgrade,multistrandcopperwirewithlowconductor resistance singlecore inopenorconcealedsystemofwiringwithspecifiedIS 694:2010 4 mm2Mtr76.5776.57200.0FalseNoneNoneFalseNoneFalse15314.00
3514639126036None5.19.4V6Supplyingand fixing regularMCBdistributionboards onwall/ood board/ flushmountingusingrequiredclamps, bolts, nuts etc.,with provision for fixing suitable type capacityMCB's single phase/3 phase/singledoorwith powdercoatedpaintingMadeoutof14SWG MS enclosure. I- Double Door. 12 Way SP & NEach2264.292264.292.0FalseNoneNoneFalseNoneFalse4528.580
3514640126036None5.18.1V6Supplying&fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materials and 'C' Type curve, indicatorON/OFF, energycross-3 withShort circuitbreaking capacityof10Kandcomplete wiringas requiredconfirmingtoIEC 60898. 6-32 A SPEach504.39504.3916.0FalseNoneNoneFalseNoneFalse8070.240
3514641126036None5.20.1V6Supplying, fixing andwiringResidualcurrentcircuitbreaker(RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 16A-25A 2 poleEach5198.275198.272.0FalseNoneNoneFalseNoneFalse10396.540
3514642126036None11.3.2V6Supplyingof .....feet-PVCBattenwith integratedLEDtube ....W withhigh quality diffuserwithLifeof25000 burninghours&70% lumen maintenance with CRI greater than 80. Power Input: 220-240V@ 50/60Hz&Power factor greater than 0.9 alongwithCE approved. 2 years Warrantyagainst anymanufacturingdefectworkingunder standard electrical condition. LED light fitting 1 x 4' - 20/22 WEach838.63838.6322.0FalseNoneNoneFalseNoneFalse18449.860
3514643126036None11.5.2V6Supply of round/square recess/surface mounted rolling type LEDDown light with ......WGU10 LEDLampRibFabricated from diecast aluminium with white powder coatedprewired to mainsconnector&hasswivellingunitofaluminiumdiecasteyeball LEDLamppositionretainedbycircularwirespring,withLifeof 25000 burning hours&70%lumenmaintenance withCRI greater than 80. PowerInput:220-240V@50/60Hz&Powerfactor greater than0.9alongwithCE approved. 2yearsWarrantyagainstanymanufacturingdefectworking under standard electrical condition. LED square or round down light 10-12WEach1075.631075.632.0FalseNoneNoneFalseNoneFalse2151.260
3514644126036None11.11.3V6Supplying&fixingof retrofit type-LEDbulb......WwithOPALacrylic diffusercomprising ofLEDsourcewithCCT6500degree K,CRI greater than 70%. efficacy greater than 80 lumen perW,life greater than25000burninghoursandCompliance toIS 10322/IEC60598,LM79&LM80.TheLEDaredrivenbyHFelectronic driver integratedinthesystem,withPF greater than 0.95,power lossshould greater than 5%of lampWage., short circuit&opencircuitprotectiontobe integrated inthe circuit,THDless than20%,LifeasperLM79.Theoperatinginputvoltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7W, 6500KEach181.09181.095.0FalseNoneNoneFalseNoneFalse905.450
3514645126036None11.11.7V6Supplying&fixingof retrofit type-LEDbulb......WwithOPALacrylic diffusercomprising ofLEDsourcewithCCT6500degree K,CRI greater than70%. efficacy greater than80 lumen perW,life greater than 25000burninghoursandCompliance toIS 10322/IEC60598,LM79&LM80.TheLEDaredrivenbyHFelectronic driver integratedinthesystem,withPF greater than0.95,power lossshould greater than 5%of lampWage., short circuit&opencircuitprotectiontobe integrated inthe circuit,THDless than20%,LifeasperLM79.Theoperatinginputvoltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18W, 6500KEach517.76517.7612.0FalseNoneNoneFalseNoneFalse6213.120
3514646126036None11.8.2V6SSupplyofLEDStreetlight luminairewithpressurediecastaluminium housing body for optimal thermal dissipation.Lamp compartment comprising ofanti glare clear diffuserwith Injectionmouldedpolycarbonatematerial, delivering superior light output Rated life Burning Hrs 50000 hr @Lumen Maintenanceof70%, maximumlightintensityshouldbebetween 60degrees to 70degrees. CCT greater than5500K, IP66optical andelectrical compartment &impact resistanceof complete luminaire greater than IK08. Power Factor greater than0.9 withmains, SurgeProtection-Min5KValongwithOver voltage/Overload, short circuit/ miss-wiring protection. Compatibleforpolemountingwithouterdiaof40mmto 50mm.UniversalVoltagedriver tooperatewidevoltage range from100Vto 270V50/60Hz application. Compliance to IS 10322/IEC60598,LM79& LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site locationwith minimized minimal tools. LED Light fixture with ........WSystem Power consumption. LED Efficiencygreater than1301m/w, nominal CRI greater than75. Luminaire manufacturer should have in-house facilityaccredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO9001:2008. Housingwith supplierwordmark/name shallbe Engraved /Embossing on thediecast housing/ Bodypart.Warrantyof2Years againstanymanufacturing defectworkingunderstandardelectricalconditionsas mentioned above should be given by LEDmanufacturer &Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40WEach4890.774890.772.0FalseNoneNoneFalseNoneFalse9781.540
3514647126036None12.27V6Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power SupplyNo63.263.22.0FalseNoneNoneFalseNoneFalse126.40
3514648126036None6.1V6Supplying exhaust fan of 1440 RPMof 300mm(12") sizewith bracket blades complete for light duty suitable tooperateon230V 50Hz, AC Supply.Each1813.381813.385.0FalseNoneNoneFalseNoneFalse9066.90
3514649126036None6.3.1V6Supplyingcapacitor typeceilingfancompletewithdownrodblades, shackle,canopiesetc,foroperationon230V,50cycles. Singlephase ACsupplyconforming toISS-374-1979andwithdoubleballbearing system. 48" Sweep (1200mm) Regular modelEach3626.753626.7512.0FalseNoneNoneFalseNoneFalse43521.00
3514650126036None12.46V6Supplying & Fixing of 70-150 W lamp holder 2 PinEach76.5776.5719.0FalseNoneNoneFalseNoneFalse1454.830
3514651126036None13.7.1V6Fixingall typesandall capacitiesof fluorescent /falseceiling/ spot light/CFL/LEDfittingsindooronthewall/ceiling/rafters/girders using 23/0.0076" twintwistedPVCinsulatedwires, requiredNosof round blocks and clamps. On wall/ ceiling / Rafter / GirdersEach148.28148.2828.0FalseNoneNoneFalseNoneFalse4151.840
3514652126036None13.11V6Fixingaceiling /wallmounting fanof all capacities andall types, withnecessaryclampsand 'S' hookmadeoutof15mmdiaMSrod, with5A. ceiling roseofapproved qualitywithnecessarylengthof 23/0.0076inchPVCinsulatedtwintwistedwireofapprovedquality, mounted on a suitable size wooden board and wired.Each382.85382.8512.0FalseNoneNoneFalseNoneFalse4594.20
3514653126036None13.13V6Fixingoneexhaust fanaftermaking asuitable notchinthewalland finishingwithcementmortarandcolouringtomatchtheexistingwall or brackets, with bolts and nuts and a 5A, ceiling rosewith sufficient lengthof23/0.0076inchPVCinsulated twincorewire of approved make with wire mesh and wooden frame.Each859.29859.295.0FalseNoneNoneFalseNoneFalse4296.450
3514654126036None13.4.1V6Supplying andfixing telescopic M.S. bracket fabricated byusing 0.5m length 4" dia telescopic M. S. pipe, with 2" dia1.5m long M.S.Bracketandareweldedwithsuitableangle,using6mmthickM. S.sheet,gripbolts&nuts,asrequired, suitablefor9to12ms.M.S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 m. LengthEach1775.71775.72.0FalseNoneNoneFalseNoneFalse3551.40
3514655126036None13.5V6Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existingpole /wall ceilingincluding clamps, bolts, nutsandwiring using suitable capacity wires.Each196.89196.892.0FalseNoneNoneFalseNoneFalse393.780
3514656126036None5.42.1V6Fabricating supplying and mounting MSboxmade out ....SWG suitableforfloor /wallmounting, fullyweather proofwith provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof lockingarrangements, with suitable size clamps with necessarycable entry pipe with gland and box should be finishedwith7tanks treatment withpowder coatedpaint and finally finished with approved colour etc., complete. 14 SWGSq CM0.610.6145000.0FalseNoneNoneFalseNoneFalse27450.00
3514657126036None5.40.1V6Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which aremounted on powder coated 40x6mmM.S.flat framework inexistingpanel board.Thebusbar shall havesuitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100 A 4 x 30 x 6 mm Aluminium Stripsm2995.962995.963.0FalseNoneNoneFalseNoneFalse8987.880
3514658126036None5.41.1V6Supplyingand fixingangle iron framework fabricatedout ofM.S. angle iron.. andM.S. Flat......withbolts,washers etc., andpainted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mmm370.7370.73.0FalseNoneNoneFalseNoneFalse1112.10
3514659126036None5.41.4V6Supplyingand fixingangle iron framework fabricatedout ofM.S. angle iron.. andM.S. Flat......withbolts,washers etc., andpainted with 2 coats of red oxide and then two coats of approved paint. 50 x 100 x 50 x 6 mm C channelm918.84918.843.0FalseNoneNoneFalseNoneFalse2756.520
3514660126036None5.14.9V6SupplyingandfixingMouldedCaseCircuitBreaker(MCCB)overthe existing wood/panel board using necessary screws, bolts, nuts, necessaryphaseseparators,handleandwiringcomplete.Protectionof OverloadandShort circuitwithadjustable thermalmagnetic release, MicroprocessorreleaseshallhaveEarthFaultasperIS/IEC60947-2. (Icu=100%lcs). In4PMCCB, all Poles shouldhaveprotection for Short-Cicrcuit/OverLoad. ForMicroprocessorMCCBS Facility for segregatingPriorityandNon-Priority loadsmust beavailable in the MCCB.MCCBshall beprovidedwithdouble insulation (insulation betweenfrontcoverandinternalpowercircuitstoavoidanyaccidental contactwith live current carryingpathwith the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE. 100 A 25 kAEach10315.110315.11.0FalseNoneNoneFalseNoneFalse10315.10
3514661126036None5.18.4V6Supplying&fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materials and 'C' Type curve, indicatorON/OFF, energycross-3 withShort circuitbreaking capacityof10Kandcomplete wiringas requiredconfirmingtoIEC 60898. 6-32 A DPEach898.18898.183.0FalseNoneNoneFalseNoneFalse2694.540
3514662126036None5.18.9V6Supplying&fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materials and 'C' Type curve, indicatorON/OFF, energycross-3 withShort circuitbreaking capacityof10Kandcomplete wiringas requiredconfirmingtoIEC 60898. 50-63 A TPNEach3753.163753.161.0FalseNoneNoneFalseNoneFalse3753.160
3514663126036None5.7.2V6Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 32 AEach292.91292.913.0FalseNoneNoneFalseNoneFalse878.730
3514664126036None5.7.3V6Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 63 AEach487.38487.381.0FalseNoneNoneFalseNoneFalse487.380
3514665126036None5.12.1Supplying of on load change over switches 4 poles,AC-23A Duty,415V,50Hz,ACSupply. Withallaccessories. (SMEnclosure Sheet Metal Execution). 63 AEach8363.178363.171.0FalseNoneNoneFalseNoneFalse8363.170
3514666126036None5.27V6Supplying, fixing andwiring rotary selector switch suitable for AmmeterEach243.08243.081.0FalseNoneNoneFalseNoneFalse243.080
3514667126036None5.28V6Supplying, fixing andwiring rotary selector switch suitable for VoltmeterEach194.46194.461.0FalseNoneNoneFalseNoneFalse194.460
3514668126036None5.29V6Supplying, fixing and wiring 3 Phase Digital Ammeter / VoltmeterEach1731.951731.952.0FalseNoneNoneFalseNoneFalse3463.90
3514669126036None5.38V6Supplying and fixing of LEDtype panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each625.93625.933.0FalseNoneNoneFalseNoneFalse1877.790
3514670126036None5.34V6Supplying, fixingandwiring50/5 to400/5A5VAburdenCurrent Transformer Class 0.5 accuracy with Tape Wound.Each683.05683.053.0FalseNoneNoneFalseNoneFalse2049.150
3514671126036None5.30V6Supplying, fixingandwiringElectronicTrivectorMeter (ETV) 5 to 20A single phase Class-1 Accuracy withTemper Proof Energy Meter.Each1677.251677.253.0FalseNoneNoneFalseNoneFalse5031.750
17207736680000NoneNoneBuildingsConstruction of Health and Wellness Center at Albal in Jamkhandi Taluk, Bagalkote District. (Sump & Septic Tank Wrok)192227.56
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3514672126037None2.5.1V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum12087.1512087.1512.375FalseNoneNoneFalseNoneFalse149578.481250
3514673126037None8.1.2V2Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm292.91292.9159.0FalseNoneNoneFalseNoneFalse17281.690
3514674126037None15.6V2Providing and laying water proofing treatment to the Water tanks & Liquid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50% applied @ 1.5 kg/m2 for internal side waterproofing in two layers with waiting period of 4-6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specification.Sqm616.21616.2129.0FalseNoneNoneFalseNoneFalse17870.090
3514675126037NoneData RateC.I Manhole cover with frame 610x455mm size.(38 Kgs) XXIVNo2499.12499.13.0FalseNoneNoneFalseNoneFalse7497.30
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17207736690000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17207736690000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17207736690001NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste as prescribed in the tender document.None
17207736690000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17207736690000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17207737050000NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of Karnataka public Procurement portal due to internet connectivity issues and technical glitches at bidders endNone
17207737150000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidderNone
17207737250000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costsNone
17207737360000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17207737450000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete mannerNone
17207738080000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to time.None
17207738250000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejected.None
17207738440000NoneNoneELIGIBILITYEarnest Money Deposit will have to be in any one of the forms as per the instructions in the financial bid document and shall have to be valid for 45 days beyond the validity of the tender.None
17207738540000NoneNoneELIGIBILITYAll formats prescribed in the bid documents shall be filled in complete manner (section 2 & of the bid document)and shall be uploaded properly, signed by tenderer. Necessary certificates shall be uploaded along with the formats wherever required. General documents section can be used for this purposeNone
17207738650000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bidNone
17207738770000NoneNoneELIGIBILITYIf the tenderer quotes bid price below the estimated contract value (Amount put to tender) then the tenderer has to submit the additional security deposit equal to the difference in cost and the additional security deposit should have a validity for the period of execution.None
17207738970000NoneNoneELIGIBILITYIf the numbers of page to be attached in one particular attachment is more, then all the pages can be put into one folder, zipped and then attached or else all the pages can be pasted in one word file and then this word file could be converted to PDF (portable documents format) format and then attached. (Please contract help desk from 9.00 AM to 9.00 PM ( Monday to Saturday) Ph No: 91-8046010000 and 91-8068948777 or send query through Karnataka public procurement portal through query option on or before specified time.None
17207739090000NoneNoneELIGIBILITYThe Contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoid damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operation.None
17207739180000NoneNoneELIGIBILITYMaterials like, steel (primary), cement, bitumen etc., required for the work shall be procured by the tenderer themselves and should be got tested positive by the quality control authority before use on the work.None
17207739270000NoneNoneELIGIBILITYTenderer should have latest GST Registration and latest clearance certificate in their nameNone
17207739380000NoneNoneELIGIBILITYThe Rates quoted by the tenderer shall be inclusive of GST.None
17207739450000NoneNoneELIGIBILITYSpecial Instructions to tenderers - as per bid document.None
17207739520000NoneNoneELIGIBILITYThe Defects Liability Period is 1 year from the date of completion of the work.None
17207739620000NoneNoneELIGIBILITYTotal value of Civil Engineering Construction works executed in the and payments received in the last five year i.e., 2019-20, 2020-21 2021-22, 2022-23 & 2023-24.None
17207739700000NoneNoneELIGIBILITYThe Tenderers are bound to furnish the original certified documents to the employer within 3 days from the day of opening of technical bid for verification, failing which the bid of tenderer will be considered as technically non responsive.None
17207739780000NoneNoneELIGIBILITYThe Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (b)(c)(d)and (e).None
17207739870000NoneNoneELIGIBILITYAs per GO No:FD-CAM/16/2022 (P-2) dated 22nd August 2022 , Banker Certificate / Line of credit shall be uploaded in the format mentioned in the SECTION -11 as per bid documentNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneClause ITT 3.2(a): To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24) The tenderer should have been achieved in at least one financial years a minimum annual financial turnover (in all classes of civil Engineering construction works only) of Rs. 64.94 Lakhs. Note : a) For Clause 3.2 (a) the certificate duly certified by the charted accountant is to be submittedPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneClause ITT 3.2(b)To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24) The tenderer should have been Satisfactorily completed at least any construction work of value not less than Rs. 16.24 Lakhs as prime contractor. Note : The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (b).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(d) The tenderer or his identified sub contractor should possess required valid electrical license for executing building electrification works issued by KPWD/ Government electrical Inspectorate and should have executed similar Building electrical works totaling Rs. 1.70 Lakhs in any one year (2019-20 to 2023-24) .Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (d). The letter of willingness of the sub contractor to be engaged for electrical works should be obtained and uploaded in the e-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause ITT 3.2(e)The Tenderer or his identified sub-contractor should possess valid license for executing water supply/sanitary engineering works issued by BWSSB/ KUWS&DB and should have executed similar building water supply/sanitary engineering works totaling Rs. 1.80 Lakhs in any one year (2019-20 to 2023-24). Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (e). The letter of willingness of the sub contractor to be engaged for water Supply works should be obtained and uploaded in the e-portalPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(c) To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24). Executed in any one year, the following minimum quantities of work Sl. No Description of key items of works Quantity 1 PCC/RCC 124.00 Cum 2 TMT Steel 6.10 T, 3 Painting 1078.00 Sqm, 4 Flooring 175.00 Sqm, 5 Plastering 1078.00 Sqm. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (c)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneKPWD Class-III & above Registration Certificate.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- KPWD Class III & above Registration certificate
NoneNoneNoneNoneClause 3.3(b)Liquid assets and /or availability of credit facilities of not less than Rs. 19.50 Lakhs (Credit lines / letter of credit/ certificates from banks for meeting the fund requirement etc.(As per the prescribed format in clause 1.10 of SECTION 3, QUALIFICATION INFORMATION of this document.) as prime Contractor.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
KPWD Class III & above Registration CertificateTrueTechnical Bid
SC Reserved Category CertificateTrueTechnical Bid
GST RegistrationTrueTechnical Bid
Work done certificateTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone