createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1720779433431
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyRESERVED
invitingStrategyTextReserved
taxTypeINCLUSIVE_TAX
tenderFee1250.00
emd50000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose23-07-2024 16:00:00
tenderQueryClose20-07-2024 16:00:00
technicalBidOpen24-07-2024 16:30:00
publishedDate16-07-2024 15:51:37
publishedByPostEWHFWD_EE_EEOFF_DWD
publishedByUserKPE13493 - SURESH S N
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonMayum Honnyal
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08362955800
mobileNumber9480036884
tenderSupplierListNone
tenderSchedule
createdTs1720779433460
version8
createdDateNone
modifiedDateNone
tenderNumberEWHFWD/2024-25/BD/WORK_INDENT446
titleCONSTRUCTION OF BLOCK LEVEL PUBLIC HEALTH UNIT AT TLH Bhatkal TALUK HOSPITAL IN UTTARA KANNADA DISTRICT
descriptionCONSTRUCTION OF BLOCK LEVEL PUBLIC HEALTH UNIT AT TLH Bhatkal TALUK HOSPITAL IN UTTARA KANNADA DISTRICT.
categoryWORKS
categoryTextWorks
ecv4962958.74
deptNameEngineering Wing of Health and Family Welfare Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3524
locationNameEWHFWD Executive Engineer Office Dharwad
provisionalAmount5000000.0
groupOverheadTotal0.0
fileNumberHFWE/AEE/HVR/BPHU/BHATKAL/15F/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17207794330000NoneNoneBuildingsCONSTRUCTION OF BLOCK LEVEL PUBLIC HEALTH UNIT AT Bhatkal TALUK HOSPITAL IN UTTARA KANNADA DISTRICT 14365941.25
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3515522126100NoneI-2.5(ii)A P-9 V-3Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle100 Sqm519.39519.392.17FalseNoneNoneFalseNoneFalse1127.07630
3515523126100NoneI-1.12 P-8 V-1Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depthCum125.55125.5587.0FalseNoneNoneFalseNoneFalse10922.850
3515524126100NoneI-1.14.1 P-8 V-1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 mCum134.8134.883.96FalseNoneNoneFalseNoneFalse11317.8080
3515525126100NoneI-1.15.1 P-8 V-1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depthCum479.74479.7435.84FalseNoneNoneFalseNoneFalse17193.88160
3515526126100NoneI-1.9 P-7 V-1Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum351.55351.5548.12FalseNoneNoneFalseNoneFalse16916.5860
3515527126100NoneI-1.8 P-7 V-1Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum626.44626.4495.75FalseNoneNoneFalseNoneFalse59981.630
3515528126100NoneI-2.1.3 P-15 V-1Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7915.067915.0614.15FalseNoneNoneFalseNoneFalse111998.0990
3515529126100NoneI-2.2.3 P-15 V-1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Formwork included) FootingsCum8624.878624.8717.25FalseNoneNoneFalseNoneFalse148779.00750
3515530126100NoneI-2.2.3 P-15 V-1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Formwork included) PEDESTALSCum9211.029211.022.59FalseNoneNoneFalseNoneFalse23856.54180
3515531126100NoneI-2.5.2 P-16 V-1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Formwork included) Columns GFCum15374.315374.39.0FalseNoneNoneFalseNoneFalse138368.70
3515532126100NoneI-2.5.2 P-16 V-1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Formwork included) PLINTH BEAM, RCC SLAB GFCum13565.5613565.5637.61FalseNoneNoneFalseNoneFalse510200.71160
3515533126100NoneI-2.5.2 P-16 V-1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Formwork included) RCC BEAMS, LINTELS GFCum14469.9314469.9313.17FalseNoneNoneFalseNoneFalse190568.97810
3515534126100NoneI-2.1.4 P-15 V-1Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates Cill concrete GFCum9038.039038.032.84FalseNoneNoneFalseNoneFalse25668.00520
3515535126100NoneI-15.4 P-135 V-3Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy GFNo.269.61269.6110.0FalseNoneNoneFalseNoneFalse2696.10
3515536126100NoneI-8.16a P-44 V-2KSRB 4-5 :Providing Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification.Sqm1636.141636.144.5FalseNoneNoneFalseNoneFalse7362.630
3515537126100NoneI-2.11 a P-84 V-1Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification GFTonne118226.37118226.376.65FalseNoneNoneFalseNoneFalse786205.36050
3515538126100NoneI-4.21 P-15 S.R 2018-19KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No . KBSRmtr38.9438.9454.0FalseNoneNoneFalseNoneFalse2102.760
3515539126100NoneA.RProviding throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. GFRmtr86.1486.1454.0FalseNoneNoneFalseNoneFalse4651.560
3515540126100NoneI-10.21 P-72 V-2Providing and fixing of Laterite cladding tiles of size 230x75x10mm thick on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with Adhesive over rough plaster surface excluding cost of rough plastered surface. The work includes cost of all materials, labour charges for all items of work, usage charges for equipment, etc., complete as per specificationCum2878.442878.441.62FalseNoneNoneFalseNoneFalse4663.07280
3515541126100NoneI-6.33 P-17 V-2Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. GFSqm1731.31731.3203.84FalseNoneNoneFalseNoneFalse352908.1920
3515542126100NoneI-6.34 P-17 V-2Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. GFSqm1459.051459.0567.33FalseNoneNoneFalseNoneFalse98237.83650
3515543126100NoneI-12.93.2 P-111 V-2Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) - Size 62 x 125mm GFm1009.71009.770.8FalseNoneNoneFalseNoneFalse71486.760
3515544126100NoneI-12.60 P-105 V-2Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. GFNos1390.321390.3212.0FalseNoneNoneFalseNoneFalse16683.840
3515545126100NoneI-12.61 P-105 V-2Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. GFNos1308.381308.3812.0FalseNoneNoneFalseNoneFalse15700.560
3515546126100NoneI-12.62 P-105 V-2Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete GFNos313.22313.2224.0FalseNoneNoneFalseNoneFalse7517.280
3515547126100NoneI-12.63 P-105 V-2Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete GFNos171.81171.8124.0FalseNoneNoneFalseNoneFalse4123.440
3515548126100NoneI-12.64 P-105 V-2Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms GFNos72.6972.6912.0FalseNoneNoneFalseNoneFalse872.280
3515549126100NoneI-12.75.1 P-108 V-2Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) GFNos363.44363.4424.0FalseNoneNoneFalseNoneFalse8722.560
3515550126100NoneI-10.6.3 P-69 V-2Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm GFNos79.379.372.0FalseNoneNoneFalseNoneFalse5709.60
3515551126100NoneI-309 (0115) P-XI S.R 2018-19Providing & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications. GFRmtr16.816.880.4FalseNoneNoneFalseNoneFalse1350.720
3515552126100NoneI-12.94.2 P-111 V-2Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum oxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 35mm thickness GFSqm5340.595340.5931.5FalseNoneNoneFalseNoneFalse168228.5850
3515553126100NoneI-12.88 P-110 V-2Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having a overall size of 60mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24mm. Windows shall be provided with 5mm plain float glass, standard hardware & single point locking system with touch lock. Wall thickness of frame & sash shall be of 2-2.5 mm. Maximum possible size 1819mm x 1819mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GFSqm7123.427123.4227.0FalseNoneNoneFalseNoneFalse192332.340
3515554126100NoneI-12.85 P-109 V-2Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GFSqm7558.237558.231.44FalseNoneNoneFalseNoneFalse10883.85120
3515555126100NoneI-11.34A P-86 V-2Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding GFKg222.03222.03597.24FalseNoneNoneFalseNoneFalse132605.19720
3515556126100NoneI-12.93.1 P-112 V-2Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)12.93.1 Size 62 x 100mm GFm927.76927.7619.8FalseNoneNoneFalseNoneFalse18369.6480
3515557126100NoneI-12.94.1 P-112 V-2Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 12.94.130 mm thickness GFSqm4605.784605.786.3FalseNoneNoneFalseNoneFalse29016.4140
3515558126100NoneI-12.59 P-105 V-2Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. GFNos1472.261472.2612.0FalseNoneNoneFalseNoneFalse17667.120
3515559126100NoneI-8.4.2 P-41 V-2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) GFSqm412.34412.34408.83FalseNoneNoneFalseNoneFalse168576.96220
3515560126100NoneI-8.51 P-50 V-2Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. GFSqm132.16132.16679.91FalseNoneNoneFalseNoneFalse89856.90560
3515561126100NoneI-8.5.2 P-42 V-2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) GFSqm520.71520.71280.26FalseNoneNoneFalseNoneFalse145934.18460
3515562126100NoneI-15.36 P-118 S.R 2018-19KSRB 15.8.3 Providing and fixing plaster mesh 200mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per Sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment ) GFRmtr42.4842.48807.0FalseNoneNoneFalseNoneFalse34281.360
3515563126100NoneI-10.5.2 P-70 S.R 2018-19Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer.Sqm283.2283.210.0FalseNoneNoneFalseNoneFalse2832.00
3515564126100NoneI-8.79 P-54 V-2Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. GFRmtr68.7268.72256.0FalseNoneNoneFalseNoneFalse17592.320
3515565126100NoneI-9.17.2 P-61 V-2Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete..Size of Tile 600x600 mm GFSqm1552.881552.88168.8FalseNoneNoneFalseNoneFalse262126.1440
3515566126100NoneI-8.2.1 P-41 V-2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GFSqm389.87389.8742.84FalseNoneNoneFalseNoneFalse16702.03080
3515567126100NoneI-9.23 P-63 V-2Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. GFSqm3259.073259.0735.27FalseNoneNoneFalseNoneFalse114947.39890
3515568126100NoneI-15.7 P-150 V-2Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) GFSqm812.78812.788.34FalseNoneNoneFalseNoneFalse6778.58520
3515569126100NoneI-9.11 P-60 V-2Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. GFSqm1174.91174.98.34FalseNoneNoneFalseNoneFalse9798.6660
3515570126100NoneI-9.39 P-65 V-2Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. GFSqm1915.01915.042.84FalseNoneNoneFalseNoneFalse82038.60
3515571126100NoneI-8.39 P-48 V-2Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GFSqm167.84167.84679.91FalseNoneNoneFalseNoneFalse114116.09440
3515572126100NoneI-8.32 P-45 V-2Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GFSqm206.17206.17280.26FalseNoneNoneFalseNoneFalse57781.20420
3515573126100NoneI-8.34.3 P-47 V-2Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GFSqm66.0866.0828.44FalseNoneNoneFalseNoneFalse1879.31520
3515574126100NoneI-8.40 P-48 V-2Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GFSqm151.98151.9828.44FalseNoneNoneFalseNoneFalse4322.31120
3515575126100NoneI-8.34.1 P-47 V-2Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GFSqm70.0470.0475.6FalseNoneNoneFalseNoneFalse5295.0240
3515576126100NoneI-647 P-A44 V-5PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary linesRmtr340.38340.3812.0FalseNoneNoneFalseNoneFalse4084.560
17207794330000NoneNoneBuildingsCONSTRUCTION OF BLOCK LEVEL PUBLIC HEALTH UNIT AT Bhatkal TALUK HOSPITAL IN UTTARA KANNADA DISTRICT- Internal water supply & sanitary works 2170329.03
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3515577126101NoneI-14.28.2.2 P-136 V-2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines GFEach121.59121.598.0FalseNoneNoneFalseNoneFalse972.720
3515578126101NoneI-16.7.4 P-191 V-5Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with: 50mm nominal bore pipes GFm183.7183.715.0FalseNoneNoneFalseNoneFalse2755.50
3515579126101NoneI-657 P-A44 V-5PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines GFm162.56162.5640.0FalseNoneNoneFalseNoneFalse6502.40
3515580126101NoneI-647 P-A44 V-5PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines GFm337.01337.0135.0FalseNoneNoneFalseNoneFalse11795.350
3515581126101NoneI-13.47 P-125 V-2Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter GFm260.36260.3620.0FalseNoneNoneFalseNoneFalse5207.20
3515582126101NoneI-14.31 P-136 V-2Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. GFEach1612.351612.354.0FalseNoneNoneFalseNoneFalse6449.40
3515583126101NoneI-14.3.1 P-131 V-2Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous chinaflushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mmflush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete,including painting of fittings and brackets, cutting and making goodthe walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid GFEach7899.27899.24.0FalseNoneNoneFalseNoneFalse31596.80
3515584126101NoneI-14.11.2 P-126 V-2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm GFNos.6716.376716.372.0FalseNoneNoneFalseNoneFalse13432.740
3515585126101NoneI-13.15 P-119 V-2Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. GFEach958.16958.164.0FalseNoneNoneFalseNoneFalse3832.640
3515586126101NoneI-14.7.1 P-124 V-2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps GFEach4073.174073.174.0FalseNoneNoneFalseNoneFalse16292.680
3515587126101NoneI-13.32.1 P-120 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes GFm408.37408.375.0FalseNoneNoneFalseNoneFalse2041.850
3515588126101NoneI-13.32.2 P-120 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes GFm500.89500.8945.0FalseNoneNoneFalseNoneFalse22540.050
3515589126101NoneI-13.33.2 P-120 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 20 mm nominal dia Pipes GFm286.79286.7920.0FalseNoneNoneFalseNoneFalse5735.80
3515590126101NoneI-13.33.3 P-120 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 25 mm nominal dia Pipes GFm391.19391.1930.0FalseNoneNoneFalseNoneFalse11735.70
3515591126101NoneI-16.9 P-162 V-5Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and coverNos.7208.017208.012.0FalseNoneNoneFalseNoneFalse14416.020
3515592126101NoneI-13.58 P-127 V-2Providing and fixing PVC (S.W.R) Gully Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete GFNos.457.27457.272.0FalseNoneNoneFalseNoneFalse914.540
3515593126101NoneI-13.34 P-123 V-2Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank.l11.8911.891000.0FalseNoneNoneFalseNoneFalse11890.00
3515594126101NoneI-14.95 P-145 V-2Providing and fixing Bidet spray made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class a Economy GFNos.1108.821108.822.0FalseNoneNoneFalseNoneFalse2217.640
17207794330000NoneNoneBuildingsCONSTRUCTION OF BLOCK LEVEL PUBLIC HEALTH UNIT AT Bhatkal TALUK HOSPITAL IN UTTARA KANNADA DISTRICT- Internal Electrification 3426688.46
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3515595126102None2.2.1Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switchPoint355.51355.5110.0FalseNoneNoneFalseNoneFalse3555.10
3515596126102None2.2.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switchPoint500.89500.8912.0FalseNoneNoneFalseNoneFalse6010.680
3515597126102None2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switchPoint733.49733.4915.0FalseNoneNoneFalseNoneFalse11002.350
3515598126102None2.2.4Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switchesPoint894.72894.725.0FalseNoneNoneFalseNoneFalse4473.60
3515599126102None3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2WayEach182.38182.385.0FalseNoneNoneFalseNoneFalse911.90
3515600126102None3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3 WayEach210.13210.135.0FalseNoneNoneFalseNoneFalse1050.650
3515601126102None3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5WayEach233.92233.923.0FalseNoneNoneFalseNoneFalse701.760
3515602126102None3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6WayEach290.75290.752.0FalseNoneNoneFalseNoneFalse581.50
3515603126102None3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 WayEach344.94344.943.0FalseNoneNoneFalseNoneFalse1034.820
3515604126102None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12WayEach421.59421.5914.0FalseNoneNoneFalseNoneFalse5902.260
3515605126102None3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 ModuleEach181.06181.065.0FalseNoneNoneFalseNoneFalse905.30
3515606126102None3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 ModuleEach212.78212.785.0FalseNoneNoneFalseNoneFalse1063.90
3515607126102None3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 ModuleEach231.28231.283.0FalseNoneNoneFalseNoneFalse693.840
3515608126102None3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 ModuleEach309.25309.252.0FalseNoneNoneFalseNoneFalse618.50
3515609126102None3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 ModuleEach375.33375.333.0FalseNoneNoneFalseNoneFalse1125.990
3515610126102None3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 ModuleEach454.63454.6314.0FalseNoneNoneFalseNoneFalse6364.820
3515611126102None3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way SwitchEach134.8134.865.0FalseNoneNoneFalseNoneFalse8762.00
3515612126102None3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socketEach225.99225.9925.0FalseNoneNoneFalseNoneFalse5649.750
3515613126102None3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two ModuleEach471.81471.8110.0FalseNoneNoneFalseNoneFalse4718.10
3515614126102None3.6.7Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switchEach237.89237.892.0FalseNoneNoneFalseNoneFalse475.780
3515615126102None3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switchEach430.84430.848.0FalseNoneNoneFalseNoneFalse3446.720
3515616126102None3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socketEach311.9311.910.0FalseNoneNoneFalseNoneFalse3119.00
3515617126102NoneI-1.13Supplyin and Fixing Metal Fan Box with Round Hook.No154.63154.6310.0FalseNoneNoneFalseNoneFalse1546.30
3515618126102None1.2.1Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thickm87.2387.23220.0FalseNoneNoneFalseNoneFalse19190.60
3515619126102None1.2.2Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thickm103.08103.08260.0FalseNoneNoneFalseNoneFalse26800.80
3515620126102None1.2.3Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thickm136.12136.1270.0FalseNoneNoneFalseNoneFalse9528.40
3515621126102None1.3.1Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thickm89.8789.87150.0FalseNoneNoneFalseNoneFalse13480.50
3515622126102None1.3.2Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thickm104.41104.41100.0FalseNoneNoneFalseNoneFalse10441.00
3515623126102None1.3.3Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thickm130.84130.8430.0FalseNoneNoneFalseNoneFalse3925.20
3515624126102None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmmm34.3634.36450.0FalseNoneNoneFalseNoneFalse15462.00
3515625126102None2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmmm55.5155.51400.0FalseNoneNoneFalseNoneFalse22204.00
3515626126102None2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmmm83.2683.26200.0FalseNoneNoneFalseNoneFalse16652.00
3515627126102None2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmmm121.59121.59170.0FalseNoneNoneFalseNoneFalse20670.30
3515628126102None5.19.4Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure I- Single Door 12 Way SP & NEach2462.142462.142.0FalseNoneNoneFalseNoneFalse4924.280
3515629126102None5.19.11Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 4 Way TPN DBEach5336.625336.621.0FalseNoneNoneFalseNoneFalse5336.620
3515630126102None5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SPEach548.46548.4618.0FalseNoneNoneFalseNoneFalse9872.280
3515631126102None5.18.3Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPNEach1071.821071.821.0FalseNoneNoneFalseNoneFalse1071.820
3515632126102None5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DPEach976.66976.664.0FalseNoneNoneFalseNoneFalse3906.640
3515633126102None5.20.1Supplying,fixing and wiring Residual current circuit breaker (RCCB)240/450V upto 300mA sensitivity on existing wood/ panel board. 16A-25A 2 poleEach5652.485652.481.0FalseNoneNoneFalseNoneFalse5652.480
3515634126102NoneBSR-32.071.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 25 sqmmKm184427.96184427.960.08FalseNoneNoneFalseNoneFalse14754.23680
3515635126102NoneBSR-21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmmKm21355.7321355.730.1FalseNoneNoneFalseNoneFalse2135.5730
3515636126102NoneSR 19-20 6.11.2Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 25mm diaEach111.01111.018.0FalseNoneNoneFalseNoneFalse888.080
3515637126102NoneI-12.57Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.No5624.735624.732.0FalseNoneNoneFalseNoneFalse11249.460
3515638126102NoneSR 19-20-6.3.1Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI stripm99.1299.1210.0FalseNoneNoneFalseNoneFalse991.20
3515639126102None11.3.2Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 wEach911.9911.914.0FalseNoneNoneFalseNoneFalse12766.60
3515640126102None11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12WEach1169.621169.628.0FalseNoneNoneFalseNoneFalse9356.960
3515641126102None11.11.3Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per watt, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should lesser than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500KEach196.92196.924.0FalseNoneNoneFalseNoneFalse787.680
3515642126102NoneI-12.46Supplying & Fixing of 70-150 Watts lamp holder 2 PinEach83.2683.264.0FalseNoneNoneFalseNoneFalse333.040
3515643126102NoneI-11.8.2Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency greater than 130lm/w, nominal CRI greater than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40WNo5318.125318.121.0FalseNoneNoneFalseNoneFalse5318.120
3515644126102NoneI-6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1971.831971.834.0FalseNoneNoneFalseNoneFalse7887.320
3515645126102None6.3.1Supplying capacitor type ceiling fan complete with down rodnblades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular modelEach3943.653943.654.0FalseNoneNoneFalseNoneFalse15774.60
3515646126102None13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / GirdersEach161.24161.2428.0FalseNoneNoneFalseNoneFalse4514.720
3515647126102NoneI-13.11Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each416.3416.38.0FalseNoneNoneFalseNoneFalse3330.40
3515648126102NoneI-13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.Each934.37934.374.0FalseNoneNoneFalseNoneFalse3737.480
3515649126102None13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. LengthEach1930.861930.861.0FalseNoneNoneFalseNoneFalse1930.860
3515650126102NoneI-13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.Each214.1214.11.0FalseNoneNoneFalseNoneFalse214.10
3515651126102None5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour etc., complete 16SWGSq CM0.570.5725000.0FalseNoneNoneFalseNoneFalse14250.00
3515652126102None5.40.1Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Stripsm3257.743257.742.0FalseNoneNoneFalseNoneFalse6515.480
3515653126102None5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mmm403.09403.098.0FalseNoneNoneFalseNoneFalse3224.720
3515654126102None5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channelm999.13999.138.0FalseNoneNoneFalseNoneFalse7993.040
3515655126102None5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) FOUR POLE 63A/100Amps 25kAEach11216.4211216.421.0FalseNoneNoneFalseNoneFalse11216.420
3515656126102None5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40 Amps TPNEach4022.954022.951.0FalseNoneNoneFalseNoneFalse4022.950
3515657126102None5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPNEach4081.14081.11.0FalseNoneNoneFalseNoneFalse4081.10
3515658126102NoneI-5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracyEach12310.712310.71.0FalseNoneNoneFalseNoneFalse12310.70
3515659126102NoneI-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.CEach680.62680.623.0FalseNoneNoneFalseNoneFalse2041.860
3515660126102NoneI-5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound (48/6.32)Each742.74742.743.0FalseNoneNoneFalseNoneFalse2228.220
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17207794370000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17207794370000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17207794370001NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Tribe as prescribed in the tender document.None
17207794370000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17207794370000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17207794780000NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of Karnataka public Procurement portal due to internet connectivity issues and technical glitches at bidders endNone
17207794870000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidderNone
17207794940000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costsNone
17207795020000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17207795100000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner.None
17207795180000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to time.None
17207795260000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejected.None
17207795350000NoneNoneELIGIBILITYEarnest Money Deposit will have to be in any one of the forms as per the instructions in the financial bid document and shall have to be valid for 45 days beyond the validity of the tender.None
17207795430000NoneNoneELIGIBILITYAll formats prescribed in the bid documents shall be filled in complete manner (section 2 & of the bid document)and shall be uploaded properly, signed by tenderer. Necessary certificates shall be uploaded along with the formats wherever required. General documents section can be used for this purposeNone
17207795520000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bidNone
17207795600000NoneNoneELIGIBILITYIf the tenderer quotes bid price below the estimated contract value (Amount put to tender) then the tenderer has to submit the additional security deposit equal to the difference in cost and the additional security deposit should have a validity for the period of execution.None
17207795690000NoneNoneELIGIBILITYIf the numbers of page to be attached in one particular attachment is more, then all the pages can be put into one folder, zipped and then attached or else all the pages can be pasted in one word file and then this word file could be converted to PDF (portable documents format) format and then attached. (Please contract help desk from 9.00 AM to 9.00 PM ( Monday to Saturday) Ph No: 91-8046010000 and 91-8068948777 or send query through Karnataka public procurement portal through query option on or before specified time.None
17207795760000NoneNoneELIGIBILITYThe Contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoid damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operation.None
17207795850000NoneNoneELIGIBILITYMaterials like, steel (primary), cement, bitumen etc., required for the work shall be procured by the tenderer themselves and should be got tested positive by the quality control authority before use on the work.None
17207795930000NoneNoneELIGIBILITYTenderer should have latest GST Registration and latest clearance certificate in their nameNone
17207796020000NoneNoneELIGIBILITYThe Rates quoted by the tenderer shall be inclusive of GST.None
17207796110000NoneNoneELIGIBILITYSpecial Instructions to tenderers - as per bid document.None
17207796190000NoneNoneELIGIBILITYThe Defects Liability Period is 1 year from the date of completion of the work.None
17207796280000NoneNoneELIGIBILITYTotal value of Civil Engineering Construction works executed in the and payments received in the last five year i.e., 2019-20, 2020-21 2021-22, 2022-23 & 2023-24.None
17207796370000NoneNoneELIGIBILITYThe Tenderers are bound to furnish the original certified documents to the employer within 3 days from the day of opening of technical bid for verification, failing which the bid of tenderer will be considered as technically non responsive.None
17207796460000NoneNoneELIGIBILITYThe Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (b)(c)(d)and (e).None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneClause ITT 3.2(a): To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24) The tenderer should have been achieved in at least one financial years a minimum annual financial turnover (in all classes of civil Engineering construction works only) of Rs. 49.63 Lakhs. Note : a) For Clause 3.2 (a) the certificate duly certified by the charted accountant is to be submittedPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneClause ITT 3.2(b)To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24) The tenderer should have been Satisfactorily completed at least any construction work of value not less than Rs. 12.41 Lakhs as prime contractor. Note : The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (b).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(d) The tenderer or his identified sub contractor should possess required valid electrical license for executing building electrification works issued by KPWD/ Government electrical Inspectorate and should have executed similar Building electrical works totaling Rs. 2.10 Lakhs in any one year (2019-20 to 2023-24) .Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (d). The letter of willingness of the sub contractor to be engaged for electrical works should be obtained and uploaded in the e-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause ITT 3.2(e)The Tenderer or his identified sub-contractor should possess valid license for executing water supply/sanitary engineering works issued by BWSSB/ KUWS&DB and should have executed similar building water supply/sanitary engineering works totaling Rs. 0.80 Lakhs in any one year (2019-20 to 2023-24). Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (e). The letter of willingness of the sub contractor to be engaged for water Supply works should be obtained and uploaded in the e-portalPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(c) To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24). Executed in any one year, the following minimum quantities of work Sl. No Description of key items of works Quantity 1 PCC/RCC 77.00 Cum 2 TMT Steel 5.30 T 3 Plastering 1230.00 Sqm 4 Painting 870.00 Sqm 5 Flooring 200.00 Sqm. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (c).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneKPWD Class-III & above Registration Certificate.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- KPWD Class III & above Registration certificate
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
KPWD Class III & above Registration CertificateTrueTechnical Bid
ST Reserved Category CertificateTrueTechnical Bid
GST RegistrationTrueTechnical Bid
Work done certificateTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone