tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1720781309000 | 0 | None | None | Buildings | CONSTRUCTION OF BLOCK LEVEL PUBLIC HEALTH UNIT AT TALUK HOSPITAL KUMTA IN UTTARA KANNADA DISTRICT. - Civil Works - FIRST FLOOR | 4213716.32 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3516521 | 126154 | None | V-2 pg no 189 Item no 19.27.1 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material to the appropriate disposal area as per direction of Engineer-in-charge. G.S. Sheet
GROUNDFLOOR | Sqm | 145.49 | 145.49 | 276.0 | False | None | None | False | None | False | 40155.24 | 0 | 3516522 | 126154 | None | V-3 pg no 1 0 Item no 2.8(ii)B | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead By Mechanical Means Lime Concrete, cement concrete grade M-20 and above FIRST FLOOR | Cum | 1478.98 | 1478.98 | 1.42 | False | None | None | False | None | False | 2100.1516 | 0 | 3516523 | 126154 | None | V-3 pg no 10 Item no 2.9(iii)B | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead Dismantling Brick / Tile work By Manual MeansDry brick pitching or brick soling FIRST FLOOR | Cum | 814.24 | 814.24 | 11.62 | False | None | None | False | None | False | 9461.4688 | 0 | 3516524 | 126154 | None | V-1 pg no 15 Item no 2.1.4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) FIRST FLOOR | Cum | 8298.55 | 8298.55 | 10.3125 | False | None | None | False | None | False | 85578.796875 | 0 | 3516525 | 126154 | None | V-1 pg no 17 Item no 2.5.1 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates COLUMNS- FIRST FLOOR | Cum | 15044.71 | 15044.71 | 3.53 | False | None | None | False | None | False | 53107.8263 | 0 | 3516526 | 126154 | None | V-1 pg no 17 Item no 2.5.1 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates LINTELS- FIRST FLOOR | Cum | 14159.73 | 14159.73 | 1.91 | False | None | None | False | None | False | 27045.0843 | 0 | 3516527 | 126154 | None | V-1 pg no 17 Item no 2.5.1 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Staircase 1 | Cum | 14159.73 | 14159.73 | 2.773 | False | None | None | False | None | False | 39264.93129 | 0 | 3516528 | 126154 | None | V-1 pg no 15 Item no 2.1.4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates FIRST FLOOR | Cum | 8298.55 | 8298.55 | 1.21 | False | None | None | False | None | False | 10041.2455 | 0 | 3516529 | 126154 | None | V-1 pg no 15 Item no 2.1.4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates FIRST FLOOR - Chejja | Cum | 12032.9 | 12032.9 | 0.43 | False | None | None | False | None | False | 5174.147 | 0 | 3516530 | 126154 | None | V1 pg no 18 Item no 2.11.a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and
technical specification Buildings | Tonne | 119408.63 | 119408.63 | 0.664 | False | None | None | False | None | False | 79287.33032 | 0 | 3516531 | 126154 | None | Data Rate | Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. | Rmtr | 86.14 | 86.14 | 56.14 | False | None | None | False | None | False | 4835.8996 | 0 | 3516532 | 126154 | None | V-2 pg no 17 Item no 6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. FIRST FLOOR- Alround outerwall ,column | Sqm | 1748.61 | 1748.61 | 132.1215 | False | None | None | False | None | False | 231028.976115 | 0 | 3516533 | 126154 | None | V-2, pg no 17 Item no 6.34 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. FIRST FLOOR Kitchen | Sqm | 1473.64 | 1473.64 | 111.51 | False | None | None | False | None | False | 164325.5964 | 0 | 3516534 | 126154 | None | V-2 pg no 100 Item no 12.13.1 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) FIRST FLOOR | Cum | 1019.8 | 1019.8 | 58.7 | False | None | None | False | None | False | 59862.26 | 0 | 3516535 | 126154 | None | V-2 pg no 105 Item no 12.5 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. FIRST FLOOR | Nos | 1356.17 | 1356.17 | 4.0 | False | None | None | False | None | False | 5424.68 | 0 | 3516536 | 126154 | None | V-2 pg no 107 Item no 12.6 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. FIRST FLOOR | Nos | 1404.23 | 1404.23 | 4.0 | False | None | None | False | None | False | 5616.92 | 0 | 3516537 | 126154 | None | V-2 pg no 107 Item no 12.61 | Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. FIRST FLOOR | Nos | 1321.47 | 1321.47 | 4.0 | False | None | None | False | None | False | 5285.88 | 0 | 3516538 | 126154 | None | V-2 pg no 107 Item no 12.62 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete FIRST FLOOR | Nos | 316.35 | 316.35 | 8.0 | False | None | None | False | None | False | 2530.8 | 0 | 3516539 | 126154 | None | V-2 pg no 107 Item no 12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete FIRST FLOOR | Nos | 173.53 | 173.53 | 8.0 | False | None | None | False | None | False | 1388.24 | 0 | 3516540 | 126154 | None | V-2 pg no 07 Item no 12.64 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms FIRST FLOOR | Nos | 73.41 | 73.41 | 4.0 | False | None | None | False | None | False | 293.64 | 0 | 3516541 | 126154 | None | V-2 pg no 108 Item no 12.75.1 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) FIRST FLOOR | Nos | 367.04 | 367.04 | 8.0 | False | None | None | False | None | False | 2936.32 | 0 | 3516542 | 126154 | None | V-2 pg no 69 Item no 10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm FIRST FLOOR | Nos | 80.09 | 80.09 | 4.0 | False | None | None | False | None | False | 320.36 | 0 | 3516543 | 126154 | None | V-1 pg no 205 Item no 20.80 | Supplying and fixing new Honne wood beads wherever necessary including cost of materials, labour, complete as per specifications. FIRST FLOOR | Rmtr | 49.56 | 49.56 | 23.0 | False | None | None | False | None | False | 1139.88 | 0 | 3516544 | 126154 | None | V-2 pg no 106 Item no 12.57.4 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side Teak FIRST FLOOR | Sqm | 6049.39 | 6049.39 | 9.12 | False | None | None | False | None | False | 55170.4368 | 0 | 3516545 | 126154 | None | V-2 pg no 110 Item no 12.90 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) FIRST FLOOR | Sqm | 8988.65 | 8988.65 | 32.4 | False | None | None | False | None | False | 291232.26 | 0 | 3516546 | 126154 | None | V-2 pg no 110 Item no 12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) FIRST FLOOR | Sqm | 7633.81 | 7633.81 | 0.72 | False | None | None | False | None | False | 5496.3432 | 0 | 3516547 | 126154 | None | V-2 pg no 110 Item no 11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding FIRST FLOOR | Kgs | 224.25 | 224.25 | 695.52 | False | None | None | False | None | False | 155970.36 | 0 | 3516548 | 126154 | None | V-2 pg no 110 Item no 12.28 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. FIRST FLOOR | Kgs | 754.17 | 754.17 | 208.74 | False | None | None | False | None | False | 157425.4458 | 0 | 3516549 | 126154 | None | V-2 pg no 112 Item no 12.96 | Providing & fixing fiber glass reinforced plastic (FRP) Door frame of cross section 90mm x 45mm having single rebate of 32mm x 15mm to recieve shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyster resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The fram,e shall be covered with fiber glass form all sides. MS stay shall be provided at the bottom to steady the frame. FIRST FLOOR | Rmtr | 858.29 | 858.29 | 9.9 | False | None | None | False | None | False | 8497.071 | 0 | 3516550 | 126154 | None | V-2 pg no 12 Item no 12.99.1 | Providing & fixing to existing door frames, 30mm thick Glass fibre reinforced plastic (FRP) panelled door shutter of required colour and approved brand and manufacture made with fire retardant grade unsaturated polyster resin, moulded to 3mm thick FRP Laminate for forming hollow railsand styles with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings cast monolithically with 5mm thick FRP Laminate for panels conforming to IS 14856 Including fixing to frames FIRST FLOOR | Sqm | 4276.75 | 4276.75 | 3.15 | False | None | None | False | None | False | 13471.7625 | 0 | 3516551 | 126154 | None | V-2 pg no 112 Item no 8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 281.65 | 281.65 | 118.01 | False | None | None | False | None | False | 33237.5165 | 0 | 3516552 | 126154 | None | V-2 pg no 42 Item no 8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. (Inside) FIRST FLOOR | Sqm | 465.85 | 465.85 | 379.38 | False | None | None | False | None | False | 176734.173 | 0 | 3516553 | 126154 | None | V-2 pg no 50 Item no 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. FIRST FLOOR | Sqm | 133.48 | 133.48 | 368.14 | False | None | None | False | None | False | 49139.3272 | 0 | 3516554 | 126154 | None | V-2 pg no 42 Item no 8.9 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Outside) FIRST FLOOR | Sqm | 513.9 | 513.9 | 145.63 | False | None | None | False | None | False | 74839.257 | 0 | 3516555 | 126154 | None | V-2 pg no 41 Item no 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.FIRST FLOOR | Sqm | 393.77 | 393.77 | 27.87 | False | None | None | False | None | False | 10974.3699 | 0 | 3516556 | 126154 | None | V2 pg no 43 Item no 8.16.2 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment 8.16.1 Plaster mesh 150mm wide FIRST FLOOR | Rmtr | 42.98 | 42.98 | 399.0 | False | None | None | False | None | False | 17149.02 | 0 | 3516557 | 126154 | None | V-2 pg no 23 Item no 7.18 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. FIRST FLOOR | Cum | 2692.32 | 2692.32 | 1.2 | False | None | None | False | None | False | 3230.784 | 0 | 3516558 | 126154 | None | V-2 pg no 134 Item no 15.7 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) FIRST FLOOR | Sqm | 820.91 | 820.91 | 8.94 | False | None | None | False | None | False | 7338.9354 | 0 | 3516559 | 126154 | None | V-2 pg no 54 Item no 8.79 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. FIRST FLOOR | Rmtr | 69.41 | 69.41 | 160.83 | False | None | None | False | None | False | 11163.2103 | 0 | 3516560 | 126154 | None | V-2 pg no 62 Item no 9.17.2 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. FIRST FLOOR | Sqm | 1568.41 | 1568.41 | 122.034 | False | None | None | False | None | False | 191399.34594 | 0 | 3516561 | 126154 | None | V-2 pg no 60 Item no 9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. FIRST FLOOR | Sqm | 1186.65 | 1186.65 | 5.98 | False | None | None | False | None | False | 7096.167 | 0 | 3516562 | 126154 | None | V-2 pg no 65 Item no 9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. FIRST FLOOR | Sqm | 1934.15 | 1934.15 | 27.87 | False | None | None | False | None | False | 53904.7605 | 0 | 3516563 | 126154 | None | V-2 pg no 61 Item no 9.14 | Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness. FIRST FLOOR | Sqm | 471.19 | 471.19 | 33.85 | False | None | None | False | None | False | 15949.7815 | 0 | 3516564 | 126154 | None | V-2 pg no 63 Item no 9.23 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. FIRST FLOOR | Sqm | 3291.66 | 3291.66 | 44.37 | False | None | None | False | None | False | 146050.9542 | 0 | 3516565 | 126154 | None | V-2 pg no 48 Item no 8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR | Sqm | 169.52 | 169.52 | 250.13 | False | None | None | False | None | False | 42402.0376 | 0 | 3516566 | 126154 | None | V-2 pg no 45 Item no 8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR | Sqm | 208.23 | 208.23 | 215.75 | False | None | None | False | None | False | 44925.6225 | 0 | 3516567 | 126154 | None | V-2 pg no 47 Item no 8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR | Sqm | 56.56 | 56.56 | 33.12 | False | None | None | False | None | False | 1873.2672 | 0 | 3516568 | 126154 | None | V-2 pg no 48 Item no 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR | Sqm | 153.5 | 153.5 | 11.07 | False | None | None | False | None | False | 1699.245 | 0 | 3516569 | 126154 | None | V-2 pg no 47 Item no 8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR | Sqm | 70.75 | 70.75 | 21.89 | False | None | None | False | None | False | 1548.7175 | 0 | 3516570 | 126154 | None | V-2 pg no 49 Item no 8.47 | Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR | Sqm | 180.2 | 180.2 | 21.89 | False | None | None | False | None | False | 3944.578 | 0 | 3516571 | 126154 | None | V-2 pg no 110 Item no 11.16.2 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(V-2 It no 11.16.2 FIRST FLOOR | Kg | 196.22 | 196.22 | 4378.5 | False | None | None | False | None | False | 859149.27 | 0 | 3516572 | 126154 | None | V-2 pg no 49 Item no 7.67.1 | Providing,fabricating and fixing Profiled Poly Urethane insulated Roof(PUF Sheet) having modular density 40kg/m2 and size 1.06m width and 7.60m
length sheets roof having external sheet of 0.5mm steel, bottom sheet of 0.40mm steel with powder coated finish. The precoated sheet shall be of
minimum 240MPa steel conforming to IS 14246 : 1995 and shal have zinc coating with minimum 120gsm as per IS 277:1992,.The roofing system shall
have suitable water proof over lapping arrangments and GRIHA ceritifed.The fasting shall be of self tapping screws of required length with PVC head along
with washer pre-painted aluminium cap unit with build in seal arrangments. The entire roof shall be firmly fastened to the existng frame including all lead
and lifts, loading & unloading ,usage charges of machinery and equipments, transportation charges,labour charges and all other incidental charges
etc.,complete as per standard technical detailed specifications and as directed by the Engineer in charge of the work FIRST FLOOR | Sqm | 2933.93 | 2933.93 | 291.9 | False | None | None | False | None | False | 856414.167 | 0 | 3516573 | 126154 | None | V-2 pg no 49 Item no 7.39.1 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :(V-2 It no 7.39.1 SR2021-22) FIRST FLOOR | Sqm | 602.0 | 602.0 | 8.505 | False | None | None | False | None | False | 5120.01 | 0 | 3516574 | 126154 | None | V-2 pg no 49 Item no 7.39.6 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :(V-2 It no 7.39.1 SR2021-22) FIRST FLOOR | Mtr | 1433.59 | 1433.59 | 52.29 | False | None | None | False | None | False | 74962.4211 | 0 |
| 1720781309000 | 0 | None | None | Buildings | CONSTRUCTION OF BLOCK LEVEL PUBLIC HEALTH UNIT AT TALUK HOSPITAL KUMTA IN UTTARA KANNADA DISTRICT - Internal Water Supply & Sanitary works | 230975.03 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3516575 | 126155 | None | V-2, I 14.28.2.2 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines | m | 121.59 | 121.59 | 8.0 | False | None | None | False | None | False | 972.72 | 0 | 3516576 | 126155 | None | V-5, I 16.7.4 | Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with: 50mm nominal bore pipes, From Sink & Urinal lines | m | 183.7 | 183.7 | 10.0 | False | None | None | False | None | False | 1837.0 | 0 | 3516577 | 126155 | None | V-5, I 10.1.5 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: Waste line PVC pipes 75mm dia., 6 kg/sqcm & class 3 | m | 290.75 | 290.75 | 30.0 | False | None | None | False | None | False | 8722.5 | 0 | 3516578 | 126155 | None | V-5, I 10.1.5 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: Sanitary Line PVC pipes 110mm dia., 6 kg/sqcm & class 3 | m | 543.18 | 543.18 | 25.0 | False | None | None | False | None | False | 13579.5 | 0 | 3516579 | 126155 | None | V-2, I 13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring
conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter | m | 384.59 | 384.59 | 20.0 | False | None | None | False | None | False | 7691.8 | 0 | 3516580 | 126155 | None | V-2, I 14.31 | Sanitary and CP fixtures Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. | Nos. | 1612.35 | 1612.35 | 3.0 | False | None | None | False | None | False | 4837.05 | 0 | 3516581 | 126155 | None | V-2, I 14.3.1 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid | Nos. | 7899.2 | 7899.2 | 4.0 | False | None | None | False | None | False | 31596.8 | 0 | 3516582 | 126155 | None | V-2, I 14.11.2 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm | Nos. | 6716.37 | 6716.37 | 7.0 | False | None | None | False | None | False | 47014.59 | 0 | 3516583 | 126155 | None | V-2, I 129 | C.P. Brass stop cock (concealed) 15 mm | Nos. | 224.67 | 224.67 | 1.0 | False | None | None | False | None | False | 224.67 | 0 | 3516584 | 126155 | None | V-2, I 14.7.1 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps | Nos. | 4073.17 | 4073.17 | 3.0 | False | None | None | False | None | False | 12219.51 | 0 | 3516585 | 126155 | None | V-2, I 13.32.1 | WATER SUPPLY Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes | m | 408.37 | 408.37 | 10.0 | False | None | None | False | None | False | 4083.7 | 0 | 3516586 | 126155 | None | V-2, I 13.32.2 | WATER SUPPLY Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes | m | 500.89 | 500.89 | 25.0 | False | None | None | False | None | False | 12522.25 | 0 | 3516587 | 126155 | None | V-2, I 13.33.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 20 mm nominal dia Pipes | m | 286.79 | 286.79 | 20.0 | False | None | None | False | None | False | 5735.8 | 0 | 3516588 | 126155 | None | V-2, I 13.33.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 25 mm nominal dia Pipes | m | 630.4 | 630.4 | 50.0 | False | None | None | False | None | False | 31520.0 | 0 | 3516589 | 126155 | None | V-2, I 13.4.1 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore | Each | 725.56 | 725.56 | 4.0 | False | None | None | False | None | False | 2902.24 | 0 | 3516590 | 126155 | None | V-2, I T130B | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN) | Each | 6577.6 | 6577.6 | 2.0 | False | None | None | False | None | False | 13155.2 | 0 | 3516591 | 126155 | None | SR 2018-19 I 12.112.2 | Providing stoneware gully trap of approved quality and make fixing in M-15 and plastering with CM 1:3 wherever necessary.( Rate includes cost of all materials, fixtures and lead).15cms x 10cms | Each | 370.05 | 370.05 | 2.0 | False | None | None | False | None | False | 740.1 | 0 | 3516592 | 126155 | None | V-2, I 739 | Providing and fixing 20mm thick grey granite For Urinals partition | Sqm | 1255.52 | 1255.52 | 5.0 | False | None | None | False | None | False | 6277.6 | 0 | 3516593 | 126155 | None | V-2, I 13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. | l | 11.89 | 11.89 | 1000.0 | False | None | None | False | None | False | 11890.0 | 0 | 3516594 | 126155 | None | Market Rate | WATER SUPPLY AND SANITARY WORKS-LAB BLOCK MARKET RATES Providing, fixing, testing and commissioning of deep seal PVC multi inlet floor trap of self cleansing design moulded or fabricated with CP grating, rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste including making good the floors etc., complete as directed by the Engineer in charge & approved quality confirming to ISI or BIS Standards | Nos. | 371.7 | 371.7 | 10.0 | False | None | None | False | None | False | 3717.0 | 0 | 3516595 | 126155 | None | Market Rate | Air Vent Cowel | Nos. | 413.0 | 413.0 | 1.0 | False | None | None | False | None | False | 413.0 | 0 | 3516596 | 126155 | None | Market Rate | Air Vent Cowel- 110mm | No | 590.0 | 590.0 | 1.0 | False | None | None | False | None | False | 590.0 | 0 | 3516597 | 126155 | None | Market rate | Sanitary and CP fixtures Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). | Nos | 2183.0 | 2183.0 | 4.0 | False | None | None | False | None | False | 8732.0 | 0 |
| 1720781309000 | 0 | None | None | Buildings | CONSTRUCTION OF BLOCK LEVEL PUBLIC HEALTH UNIT AT TALUK HOSPITAL KUMTA IN UTTARA KANNADA DISTRICT. -Internal Electrification Works | 492365.47 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3516598 | 126156 | None | 2.2.1 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch | Point | 355.51 | 355.51 | 10.0 | False | None | None | False | None | False | 3555.1 | 0 | 3516599 | 126156 | None | 2.2.2 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch | Point | 500.89 | 500.89 | 12.0 | False | None | None | False | None | False | 6010.68 | 0 | 3516600 | 126156 | None | 2.2.3 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch | Point | 733.49 | 733.49 | 15.0 | False | None | None | False | None | False | 11002.35 | 0 | 3516601 | 126156 | None | 2.2.4 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches | Point | 894.72 | 894.72 | 5.0 | False | None | None | False | None | False | 4473.6 | 0 | 3516602 | 126156 | None | 3.4.1 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2Way | Each | 182.38 | 182.38 | 5.0 | False | None | None | False | None | False | 911.9 | 0 | 3516603 | 126156 | None | 3.4.2 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1- 3 Way | Each | 210.14 | 210.14 | 5.0 | False | None | None | False | None | False | 1050.7 | 0 | 3516604 | 126156 | None | 3.4.3 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1- 4-5Way | Each | 233.92 | 233.92 | 3.0 | False | None | None | False | None | False | 701.76 | 0 | 3516605 | 126156 | None | 3.4.4 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1- 6Way | Each | 290.75 | 290.75 | 2.0 | False | None | None | False | None | False | 581.5 | 0 | 3516606 | 126156 | None | 3.4.5 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-8 Way | Each | 344.94 | 344.94 | 3.0 | False | None | None | False | None | False | 1034.82 | 0 | 3516607 | 126156 | None | 3.4.6 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1- 10-12Way | Each | 421.59 | 421.59 | 14.0 | False | None | None | False | None | False | 5902.26 | 0 | 3516608 | 126156 | None | 3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module | Each | 181.06 | 181.06 | 5.0 | False | None | None | False | None | False | 905.3 | 0 | 3516609 | 126156 | None | 3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 3 Module | Each | 212.78 | 212.78 | 5.0 | False | None | None | False | None | False | 1063.9 | 0 | 3516610 | 126156 | None | 3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box4 Module | Each | 231.28 | 231.28 | 3.0 | False | None | None | False | None | False | 693.84 | 0 | 3516611 | 126156 | None | 3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 6 Module | Each | 309.25 | 309.25 | 2.0 | False | None | None | False | None | False | 618.5 | 0 | 3516612 | 126156 | None | 3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 8 Module | Each | 375.33 | 375.33 | 3.0 | False | None | None | False | None | False | 1125.99 | 0 | 3516613 | 126156 | None | 3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 8 Module 10-12 Module
| Each | 454.63 | 454.63 | 14.0 | False | None | None | False | None | False | 6364.82 | 0 | 3516614 | 126156 | None | 3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch
| Each | 134.8 | 134.8 | 75.0 | False | None | None | False | None | False | 10110.0 | 0 | 3516615 | 126156 | None | 3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket
| Each | 225.99 | 225.99 | 30.0 | False | None | None | False | None | False | 6779.7 | 0 | 3516616 | 126156 | None | 3.6.4 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module
| Each | 471.81 | 471.81 | 10.0 | False | None | None | False | None | False | 4718.1 | 0 | 3516617 | 126156 | None | 3.6.7 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch
| Each | 237.89 | 237.89 | 2.0 | False | None | None | False | None | False | 475.78 | 0 | 3516618 | 126156 | None | 3.6.9 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch
| Each | 430.84 | 430.84 | 8.0 | False | None | None | False | None | False | 3446.72 | 0 | 3516619 | 126156 | None | 3.6.10 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket
| Each | 311.9 | 311.9 | 10.0 | False | None | None | False | None | False | 3119.0 | 0 | 3516620 | 126156 | None | 1.13 | Supplying and Fixing Metal Fan Box with Round Hook.
| No | 117.0 | 117.0 | 10.0 | False | None | None | False | None | False | 1170.0 | 0 | 3516621 | 126156 | None | 1.2.1 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick
| m | 87.23 | 87.23 | 250.0 | False | None | None | False | None | False | 21807.5 | 0 | 3516622 | 126156 | None | 1.2.1 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick
| m | 103.08 | 103.08 | 300.0 | False | None | None | False | None | False | 30924.0 | 0 | 3516623 | 126156 | None | 1.2.3 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick
| m | 136.12 | 136.12 | 70.0 | False | None | None | False | None | False | 9528.4 | 0 | 3516624 | 126156 | None | 1.3.1 | Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick
| m | 89.87 | 89.87 | 150.0 | False | None | None | False | None | False | 13480.5 | 0 | 3516625 | 126156 | None | 1.32 | Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick
| m | 104.41 | 104.41 | 100.0 | False | None | None | False | None | False | 10441.0 | 0 | 3516626 | 126156 | None | 1.3.3 | Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick
| m | 130.84 | 130.84 | 30.0 | False | None | None | False | None | False | 3925.2 | 0 | 3516627 | 126156 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm
| m | 34.36 | 34.36 | 170.0 | False | None | None | False | None | False | 5841.2 | 0 | 3516628 | 126156 | None | 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm
| m | 55.51 | 55.51 | 600.0 | False | None | None | False | None | False | 33306.0 | 0 | 3516629 | 126156 | None | 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm
| m | 83.26 | 83.26 | 230.0 | False | None | None | False | None | False | 19149.8 | 0 | 3516630 | 126156 | None | 2.3.5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm
| m | 121.59 | 121.59 | 200.0 | False | None | None | False | None | False | 24318.0 | 0 | 3516631 | 126156 | None | 5.19.4 | MCB DB Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure I- Single Door 12 Way SP & N | Each | 2462.14 | 2462.14 | 2.0 | False | None | None | False | None | False | 4924.28 | 0 | 3516632 | 126156 | None | 5.19.11 | MCB DB Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure I III - Double Door 4 Way TPN DB
| Each | 5336.62 | 5336.62 | 1.0 | False | None | None | False | None | False | 5336.62 | 0 | 3516633 | 126156 | None | 5.18.1 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898- 6-32Amps SP
| Each | 548.46 | 548.46 | 20.0 | False | None | None | False | None | False | 10969.2 | 0 | 3516634 | 126156 | None | 5.18.3 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898- 50-63Amps TPN
| Each | 1071.82 | 1071.82 | 1.0 | False | None | None | False | None | False | 1071.82 | 0 | 3516635 | 126156 | None | 5.18.4 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898- 6-32Amps DP
| Each | 976.66 | 976.66 | 2.0 | False | None | None | False | None | False | 1953.32 | 0 | 3516636 | 126156 | None | 5.20.1 | Supplying,fixing and wiring Residual current circuit breaker (RCCB)240/450V upto 300mA sensitivity on existing wood/ panel board. - 16A-25A 2 pole
| Each | 5652.48 | 5652.48 | 1.0 | False | None | None | False | None | False | 5652.48 | 0 | 3516637 | 126156 | None | BSR-32- 32.07 | LT UG CABLES 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS 1554 (Part 1) or IS 7098 Part 1, Armouring strip thickness and resistivity as per IS 3975 3.5 core 25 sqm | Km | 184427.97 | 184427.97 | 0.1 | False | None | None | False | None | False | 18442.797 | 0 | 3516638 | 126156 | None | BSR-21.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm
| Km | 21355.73 | 21355.73 | 0.1 | False | None | None | False | None | False | 2135.573 | 0 | 3516639 | 126156 | None | SR 19-20 6.11.2 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 25mm dia
| Each | 111.01 | 111.01 | 8.0 | False | None | None | False | None | False | 888.08 | 0 | 3516640 | 126156 | None | 12.57 | EARTHING
Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. | No | 5624.73 | 5624.73 | 2.0 | False | None | None | False | None | False | 11249.46 | 0 | 3516641 | 126156 | None | SR 23-24 V-6 i.no12.58.2 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip
| m | 82.0 | 82.0 | 15.0 | False | None | None | False | None | False | 1230.0 | 0 | 3516642 | 126156 | None | 11.3.2 | ELECTRICAL FIXTURES
Supplying of feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4 20/22 w | Each | 911.9 | 911.9 | 20.0 | False | None | None | False | None | False | 18238.0 | 0 | 3516643 | 126156 | None | 11.5.2 | Supply of round/square recess/surface mounted rolling type LED Down light with.W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition- LED square or round down light 10-12W | Each | 1169.62 | 1169.62 | 8.0 | False | None | None | False | None | False | 9356.96 | 0 | 3516644 | 126156 | None | 11.11.3 | Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.- 7 W, 6500K | Each | 196.92 | 196.92 | 4.0 | False | None | None | False | None | False | 787.68 | 0 | 3516645 | 126156 | None | 12.46 | Supplying & Fixing of 70-150 Watts lamp holder 2 Pin
| Each | 83.26 | 83.26 | 4.0 | False | None | None | False | None | False | 333.04 | 0 | 3516646 | 126156 | None | 11.8.2 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40W | No | 5318.12 | 5318.12 | 1.0 | False | None | None | False | None | False | 5318.12 | 0 | 3516647 | 126156 | None | 6.1 | Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.
| No | 1971.83 | 1971.83 | 4.0 | False | None | None | False | None | False | 7887.32 | 0 | 3516648 | 126156 | None | 6.3.1 | Supplying capacitor type ceiling fan complete with down rodnblades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model
| Each | 3943.65 | 3943.65 | 10.0 | False | None | None | False | None | False | 39436.5 | 0 | 3516649 | 126156 | None | 13.7.1 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders
| Each | 161.24 | 161.24 | 28.0 | False | None | None | False | None | False | 4514.72 | 0 | 3516650 | 126156 | None | 13.11 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.
| Each | 416.3 | 416.3 | 10.0 | False | None | None | False | None | False | 4163.0 | 0 | 3516651 | 126156 | None | 13.13 | Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.
| Each | 934.37 | 934.37 | 4.0 | False | None | None | False | None | False | 3737.48 | 0 | 3516652 | 126156 | None | 13.4.1 | Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length
| Each | 1930.86 | 1930.86 | 1.0 | False | None | None | False | None | False | 1930.86 | 0 | 3516653 | 126156 | None | 13.5 | Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.
| Each | 214.1 | 214.1 | 1.0 | False | None | None | False | None | False | 214.1 | 0 | 3516654 | 126156 | None | 5.42.2 | L.T.PANEL Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour etc., complete 16SWG
| Sqm | 0.57 | 0.57 | 40000.0 | False | None | None | False | None | False | 22800.0 | 0 | 3516655 | 126156 | None | 5.40.1 | Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips
| m | 3257.74 | 3257.74 | 2.0 | False | None | None | False | None | False | 6515.48 | 0 | 3516656 | 126156 | None | 5.41.1 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint - 40x40x6mm
| m | 403.09 | 403.09 | 8.0 | False | None | None | False | None | False | 3224.72 | 0 | 3516657 | 126156 | None | 5.41.4 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint - 50x100x50x6mm C channel
| m | 999.13 | 999.13 | 8.0 | False | None | None | False | None | False | 7993.04 | 0 | 3516658 | 126156 | None | 15.15.9 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) - FOUR POLE- 63A/100Amps 25kA
| Each | 11216.42 | 11216.42 | 1.0 | False | None | None | False | None | False | 11216.42 | 0 | 3516659 | 126156 | None | 5.18.1 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 -
6-32Amps SP | Each | 548.46 | 548.46 | 3.0 | False | None | None | False | None | False | 1645.38 | 0 | 3516660 | 126156 | None | 5.18.4 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 -
6-32Amps DP | Each | 976.66 | 976.66 | 2.0 | False | None | None | False | None | False | 1953.32 | 0 | 3516661 | 126156 | None | 5.17.9 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 -
40 Amps TPN | Each | 4022.95 | 4022.95 | 2.0 | False | None | None | False | None | False | 8045.9 | 0 | 3516662 | 126156 | None | 5.17.19 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 -
50-63Amps TPN | Each | 4081.1 | 4081.1 | 1.0 | False | None | None | False | None | False | 4081.1 | 0 | 3516663 | 126156 | None | 5.33 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy
| Each | 12310.7 | 12310.7 | 1.0 | False | None | None | False | None | False | 12310.7 | 0 | 3516664 | 126156 | None | 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C
| Each | 680.62 | 680.62 | 3.0 | False | None | None | False | None | False | 2041.86 | 0 | 3516665 | 126156 | None | 5.34 | Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound (48/6.32)
| Each | 742.74 | 742.74 | 3.0 | False | None | None | False | None | False | 2228.22 | 0 |
|
|
---|