createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1720787669739
version6
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee2040.00
emd192000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose01-08-2024 17:00:00
tenderQueryClose31-07-2024 17:00:00
technicalBidOpen03-08-2024 11:00:00
publishedDate16-07-2024 18:29:28
publishedByPostDUDC_EE_KLB
publishedByUserKPE11288 - SHIVANAGOUDA S PATIL
bidValidityPeriod90
noOfCalls2
preBidMeetingDate27-07-2024 11:30:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnTrue
percentageRateTypeTextNone
contactPersonSomu Rathod
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9880510192
tenderSupplierListNone
tenderSchedule
createdTs1720787669742
version17
createdDateNone
modifiedDateNone
tenderNumberDMA/2023-24/OW/WORK_INDENT17574/CALL-2
titleDevelopment of Sevalal temple in ward no 4 in wadi town. Construction of Maratha asn sevlal bhavan in wadi town. Constrcution of Toilet for Physically disabled peoples in wadi town.
descriptionDevelopment of Sevalal temple in ward no 4 in wadi town. Construction of Maratha asn sevlal bhavan in wadi town. Constrcution of Toilet for Physically disabled peoples in wadi town.
categoryWORKS
categoryTextWorks
ecv8123342.02
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2188
locationNameDMA District Urban Development Cell Kalaburagi
provisionalAmount9625000.0
groupOverheadTotalNone
fileNumberTMCWadi/CMSTDP4/1
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17207876700001NoneNoneOther WorksConstruction of Maratha and Savita Smaja Bhavan in wadi town.4247483.72
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3518302126275Nonecode01Construction of Maratha samaja bhavan Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. Depth exceeding 1.5m, but not exceeding 3 mCum467.25467.25115.46FalseNoneNoneFalseNoneFalse53948.6850
3518303126275Nonecode02Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum6288.456288.458.61FalseNoneNoneFalseNoneFalse54143.55450
3518304126275Nonecode03Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7170.287170.2814.7FalseNoneNoneFalseNoneFalse105403.1160
3518305126275Nonecode04Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6515.256515.2525.34FalseNoneNoneFalseNoneFalse165096.4350
3518306126275Nonecode05Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.459.61FalseNoneNoneFalseNoneFalse64468.20450
3518307126275Nonecode06Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer in charge.Sqm267.75267.7533.684FalseNoneNoneFalseNoneFalse9018.8910
3518308126275Nonecode07Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11566.811566.85.53FalseNoneNoneFalseNoneFalse63964.4040
3518309126275Nonecode08Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10886.410886.42.01FalseNoneNoneFalseNoneFalse21881.6640
3518310126275Nonecode09Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.3110.39FalseNoneNoneFalseNoneFalse30831.9270
3518311126275Nonecode10Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8376.98376.950.36FalseNoneNoneFalseNoneFalse421860.6840
3518312126275Nonecode11Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11138.411138.42.23FalseNoneNoneFalseNoneFalse24838.6320
3518313126275Nonecode12Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, uring and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11138.411138.40.4049FalseNoneNoneFalseNoneFalse4509.938160
3518314126275Nonecode13Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10886.410886.43.412FalseNoneNoneFalseNoneFalse37144.39680
3518315126275Nonecode14Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10442.2510442.2515.2925FalseNoneNoneFalseNoneFalse159688.1081250
3518316126275Nonecode15Supplying, Fitting and Placing TMT Fe 500 & above Reinforcement in Foundation / Substructure Superstructure complete as per Drawing and Technical Specifications.Tonne90754.6590754.652.572FalseNoneNoneFalseNoneFalse233420.95980
3518317126275Nonecode16Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin Charge. Page No.82 Item no.11.26.1 KPWD. Volumn 2 DSR2023 24Kg144.9144.978.37FalseNoneNoneFalseNoneFalse11355.8130
3518318126275Nonecode17Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum144977.7144977.70.1025FalseNoneNoneFalseNoneFalse14860.214250
3518319126275Nonecode18Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer in charge.Sqm333.9333.90.3FalseNoneNoneFalseNoneFalse100.170
3518320126275Nonecode19Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer in charge fixed to frames with 3 nos of 75mm Aluminium hinges with one side prelamSqm2142.02142.01.89FalseNoneNoneFalseNoneFalse4048.380
3518321126275Nonecode20Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.Sqm192.15192.15211.68FalseNoneNoneFalseNoneFalse40674.3120
3518322126275Nonecode21Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, uring complete as per specifications and as per directions of Engineer in charge.Sqm253.05253.05144.3474FalseNoneNoneFalseNoneFalse36527.109570
3518323126275Nonecode22Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per pecifications and as per directions of Engineer in charge.Sqm105.0105.0144.3474FalseNoneNoneFalseNoneFalse15156.4770
3518324126275Nonecode23Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement ortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever equired smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in charge.Sqm389.55389.55236.2107FalseNoneNoneFalseNoneFalse92015.8781850
3518325126275Nonecode24Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per pecifications and as per directions of Engineer in charge.Sqm133.35133.35144.3474FalseNoneNoneFalseNoneFalse19248.725790
3518326126275Nonecode25Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied at the rate 1.43 ltr/10 over and including priming coat of exterior primer applied at the rate 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to move all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer in charge.Sqm186.9186.9236.21FalseNoneNoneFalseNoneFalse44147.6490
3518327126275Nonecode26Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter ncluding preparing the surface even and sand paper smooth, cost of materials, labour complete as per pecifications and as per directions of Engineer in charge.Sqm120.75120.7518.0FalseNoneNoneFalseNoneFalse2173.50
3518328126275Nonecode27Providing & fixing of 3 track x 2 panel sliding windows made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile hrough out the window frame The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm nd mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm 2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm7070.77070.79.0FalseNoneNoneFalseNoneFalse63636.30
3518329126275Nonecode28Providing and fixing in position fully panelled Honne wood shutters for doors with , stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures)Sqm9952.959952.954.2FalseNoneNoneFalseNoneFalse41802.390
3518330126275Nonecode29Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer in charge.Sqm141.75141.758.4FalseNoneNoneFalseNoneFalse1190.70
3518331126275Nonecode30Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry at the rate 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 800x800 mmSqm1351.351351.3563.1973FalseNoneNoneFalseNoneFalse85401.6713550
3518332126275Nonecode31WATER SUPPLY WORKS Of Maratha samja Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work Exposed on wallMtr333.9333.910.0FalseNoneNoneFalseNoneFalse3339.00
3518333126275Nonecode32Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the elected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.Cum508.2508.210.0FalseNoneNoneFalseNoneFalse5082.00
3518334126275Nonecode33Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and ommissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For:Mtr70.3570.3510.0FalseNoneNoneFalseNoneFalse703.50
3518335126275Nonecode34P/F PTMT BIB COCK Providing and fixing PTMT bib cock of approved quality and colour.15mm nominal bore, 86 mm long, weighing not less than 88 gNo167.48167.486.0FalseNoneNoneFalseNoneFalse1004.880
3518336126275Nonecode35P/F PTMT STOPCOCK CONCEALED Concealed stop cock, 15 mm nominal bore, 108 mm long, weighing not less than 108 gmsNo213.06213.062.0FalseNoneNoneFalseNoneFalse426.120
3518337126275Nonecode36P/F BRASS BALL VALVE Providing and fixing Brass full way valve gate with C.I. wheel of Approved quality (screwed end) : ( item no 13..4.1 ) page no 115 PWP. DSR 2023 24No581.94581.942.0FalseNoneNoneFalseNoneFalse1163.880
3518338126275Nonecode37P/F WASH BASIN Providing and fixing wash basin with C.I. brackets, 15 mm PTMT pillar cock, 32 mm PTMT waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm PTMT pillar cock. (item no 14.7B ) page no 125 PWP. DSR 2023 24No2410.82410.81.0FalseNoneNoneFalseNoneFalse2410.80
3518339126275Nonecode3815 mm nominal bore, 125 mm long foam flow, weighing not less than 120 gms13No332.84332.842.0FalseNoneNoneFalseNoneFalse665.680
3518340126275Nonecode39PVC connection pipeNo96.4696.461.0FalseNoneNoneFalseNoneFalse96.460
3518341126275Nonecode40SANITARY WORK WATER CLOSET EUROPEAN TYPE Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : ( item no 14.2 ) page no 123 PWP. DSR 2023 24Pan5079.05079.01.0FalseNoneNoneFalseNoneFalse5079.00
3518342126275Nonecode41WASTE PIPE Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe32 mm dia ( item no 14.28.2.1 ) page no 123 PWP. DSR 2023 24Each97.5297.521.0FalseNoneNoneFalseNoneFalse97.520
3518343126275Nonecode42WASTE PIPE RIGID Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. SEMI RIGID pipe32 mm dia ( item no 14.28.1.1 ) page no 123 PWP. DSR 2023 24Each80.5680.561.0FalseNoneNoneFalseNoneFalse80.560
3518344126275Nonecode43PVC PIPE Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN4, 110mm dia. ( item no 2.2) page no 134 VOLUME 5 PWP. DSR 2023 24Mtr287.26287.266.0FalseNoneNoneFalseNoneFalse1723.560
3518345126275Nonecode44Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base suooort for tank.Ltr9.459.451000.0FalseNoneNoneFalseNoneFalse9450.00
3518346126275Nonecode45WASTE PIPE RIGID Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe32 mm dia ( item no 14.28.2.1 ) page no 123 PWP. DSR 2023 24Each97.5297.521.0FalseNoneNoneFalseNoneFalse97.520
3518347126275Nonecode46Sinking of Maratha samaj Borewell Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M 15%, b) Above 30 M 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/ is to be deducted for Dry Borewell towards yield test. etc. complete (KPWD SR VOL V for the year 2023 24. I. No. 12.4 P.No. 140 )No5552.05552.01.0FalseNoneNoneFalseNoneFalse5552.00
3518348126275Nonecode47Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 0 to 50 Mtrs (KPWD SR VOL V for the year 2023 24. I. No. 12.1.1 P.No. 132 )Mtr388.5388.550.0FalseNoneNoneFalseNoneFalse19425.00
3518349126275Nonecode48Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 50 to 100 Mtrs (KPWD SR VOL V for the year 2023 24. I. No. 12.1.2 P.No. 132 )Mtr487.2487.250.0FalseNoneNoneFalseNoneFalse24360.00
3518350126275Nonecode49Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 100 to 150 Mtrs (KPWD SR VOL V for the year 2023 24. I. No. 12.1.3 P.No. 132 )Mtr517.65517.6510.0FalseNoneNoneFalseNoneFalse5176.50
3518351126275Nonecode50PVC pipes of 6 Kg/cm2 for 160mm (KPWD SR VOL V for the year 2023 24. Sl No. 649 P.No. A44 )Mtr441.0441.06.0FalseNoneNoneFalseNoneFalse2646.00
3518352126275Nonecode51PVC pipes of 6 Kg/cm2 for 110mm (KPWD SR VOL V for the year 2023 24. Sl No. 647 P.No. A44 )Mtr267.75267.75110.0FalseNoneNoneFalseNoneFalse29452.50
3518353126275Nonecode52Providing and laying at site of work MS casing caps as per IS 1239 (part II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part II) 1982 with all Amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in Charge ( (PWD UGD and water supply SR 2023 24 Volume V Item no.12.34 page no.143)Mtr172.2172.21.0FalseNoneNoneFalseNoneFalse172.20
3518354126275Nonecode53Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034 2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest ammendments 1.50 HP/1.1KW 20 STG (PWD UGD and water supply SR 2023 24 Volume V Item no.13.7.7 page no.150)No19128.919128.91.0FalseNoneNoneFalseNoneFalse19128.90
3518355126275Nonecode54Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. (PWD UGD and water supply SR 2023 24 Volume V Item no.13.31 page no.155)Mtr42.042.0110.0FalseNoneNoneFalseNoneFalse4620.00
3518356126275Nonecode55Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. (PWD UGD and water supply SR 2023 24 Volume V Item no.13.32 page no.156)Job6825.06825.01.0FalseNoneNoneFalseNoneFalse6825.00
3518357126275Nonecode56Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694 1990 with ISI Mark and as per its latest amendments. 1x3x6 Sqm. (PWD UGD and water supply SR 2023 24 Volume V Item no.13.22.4 page no.154)Mtr194.25194.25115.0FalseNoneNoneFalseNoneFalse22338.750
3518358126275Nonecode57Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984 2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 (PWD UGD and water supply SR 2023 24 Volume V Item no.9.1.1 page no.95)Mtr198.45198.45105.0FalseNoneNoneFalseNoneFalse20837.250
3518359126275Nonecode58Supply and delivery at site of brand new best make non return valve as per IS 778/1984 with ISI Mark and as per its latest amendments (PWD UGD and water supply SR 2023 24 Volume V Item no.13.25.2 page no.154)No1627.51627.51.0FalseNoneNoneFalseNoneFalse1627.50
3518360126275Nonecode59Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL Direct Online Starter 2) S D Star Delta Starter etc. complete.Upto 3 HP pumps (PWD UGD and water supply SR 2023 24 Volume V Item no.13.24.1 page no.155)Each7875.07875.01.0FalseNoneNoneFalseNoneFalse7875.00
3518361126275Nonecode60Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer incharge of work. (PWD UGD and water supply SR 2023 24 Volume V Item no.13.34 page no.156)Job1522.51522.51.0FalseNoneNoneFalseNoneFalse1522.50
3518362126275Nonecode61Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets. (PWD UGD and water supply SR 2023 24 Volume V Item no.13.25 page no.155)Kvar577.5577.51.0FalseNoneNoneFalseNoneFalse577.50
3518363126275Nonecode62Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box. (PWD UGD and water supply SR 2023 24 Volume V Item no.13.26 page no.155)No1207.51207.51.0FalseNoneNoneFalseNoneFalse1207.50
3518364126275Nonecode63Labour charges for providing connection using insulated sheathed steel wire cable as per IS 1554/ 1988 with latest amendments from KPTCL pole to meter board unit, with all necessary materials ,tools and equipments,as per specificationswith testing of as per instructions of engineer incharge of work. 3.5 x 16 sqmm (PWD UGD and water supply SR 2023 24 Volume V Item no.13.35.2 page no.156)No168.0168.01.0FalseNoneNoneFalseNoneFalse168.00
3518365126275Nonecode64ELECTRICAL WORK Construction of Savitha samaj Bhavan Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and leadCum754.95754.954.675FalseNoneNoneFalseNoneFalse3529.391250
3518366126275Nonecode65PWD SR 2023 24 V III Item No. 2.11 (ii) A, Page No. 08Cum189.0189.060.2174FalseNoneNoneFalseNoneFalse11381.08860
3518367126275Nonecode66PWD SR 2023 24 V III Item No. 2.13 B, Page No. 09Sqm2109.452109.451.9925FalseNoneNoneFalseNoneFalse4203.0791250
3518368126275Nonecode67Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. Depth exceeding 1.5m, but not exceeding 3 mCum467.25467.25115.46FalseNoneNoneFalseNoneFalse53948.6850
3518369126275Nonecode68Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum6288.456288.458.61FalseNoneNoneFalseNoneFalse54143.55450
3518370126275Nonecode69Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7170.287170.2814.7FalseNoneNoneFalseNoneFalse105403.1160
3518371126275Nonecode70Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6515.256515.2525.3381FalseNoneNoneFalseNoneFalse165084.0560250
3518372126275Nonecode71Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.459.608FalseNoneNoneFalseNoneFalse64454.78760
3518373126275Nonecode72Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer in charge.Sqm267.75267.7533.684FalseNoneNoneFalseNoneFalse9018.8910
3518374126275Nonecode73Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11566.811566.85.5269FalseNoneNoneFalseNoneFalse63928.546920
3518375126275Nonecode74Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10886.410886.42.006FalseNoneNoneFalseNoneFalse21838.11840
3518376126275Nonecode75Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.3110.393FalseNoneNoneFalseNoneFalse30832.76490
3518377126275Nonecode76Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8376.98376.950.3591FalseNoneNoneFalseNoneFalse421853.144790
3518378126275Nonecode77Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11138.411138.42.23FalseNoneNoneFalseNoneFalse24838.6320
3518379126275Nonecode78Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, uring and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11138.411138.40.404FalseNoneNoneFalseNoneFalse4499.91360
3518380126275Nonecode79Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10206.010206.03.412FalseNoneNoneFalseNoneFalse34822.8720
3518381126275Nonecode80Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10442.2510442.2515.2925FalseNoneNoneFalseNoneFalse159688.1081250
3518382126275Nonecode81Supplying, Fitting and Placing TMT Fe 500 & above Reinforcement in Foundation / Substructure Superstructure complete as per Drawing and Technical Specifications.Tonne90754.6590754.652.572FalseNoneNoneFalseNoneFalse233420.95980
3518383126275Nonecode82Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum144977.7144977.70.1025FalseNoneNoneFalseNoneFalse14860.214250
3518384126275Nonecode83Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer in charge.Sqm333.9333.90.3FalseNoneNoneFalseNoneFalse100.170
3518385126275Nonecode84Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer in charge fixed to frames with 3 nos of 75mm Aluminium hinges with one side prelamSqm2142.02142.01.89FalseNoneNoneFalseNoneFalse4048.380
3518386126275Nonecode85Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.Sqm192.15192.15211.68FalseNoneNoneFalseNoneFalse40674.3120
3518387126275Nonecode86Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin Charge. Page No.82 Item no.11.26.1 KPWD. Volumn 2 DSR2023 24Kg144.9144.978.37FalseNoneNoneFalseNoneFalse11355.8130
3518388126275Nonecode87Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, uring complete as per specifications and as per directions of Engineer in charge.Sqm253.05253.05144.3474FalseNoneNoneFalseNoneFalse36527.109570
3518389126275Nonecode88Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per pecifications and as per directions of Engineer in charge.Sqm105.0105.0144.3474FalseNoneNoneFalseNoneFalse15156.4770
3518390126275Nonecode89Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement ortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever equired smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in charge.Sqm389.55389.55236.21FalseNoneNoneFalseNoneFalse92015.60550
3518391126275Nonecode90Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per pecifications and as per directions of Engineer in charge.Sqm133.35133.35144.3474FalseNoneNoneFalseNoneFalse19248.725790
3518392126275Nonecode91Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied at the rate 1.43 ltr/10 m² over and including priming coat of exterior primer applied at the rate 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to move all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer in charge.Sqm186.9186.9236.21FalseNoneNoneFalseNoneFalse44147.6490
3518393126275Nonecode92Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter ncluding preparing the surface even and sand paper smooth, cost of materials, labour complete as per pecifications and as per directions of Engineer in charge.Sqm120.75120.7518.0FalseNoneNoneFalseNoneFalse2173.50
3518394126275Nonecode93Providing & fixing of 3 track x 2 panel sliding windows made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile hrough out the window frame The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm nd mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm 2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm7070.77070.79.0FalseNoneNoneFalseNoneFalse63636.30
3518395126275Nonecode94Providing and fixing in position fully panelled Honne wood shutters for doors with , stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures)Sqm7439.257439.254.2FalseNoneNoneFalseNoneFalse31244.850
3518396126275Nonecode95Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer in charge.Sqm141.75141.758.4FalseNoneNoneFalseNoneFalse1190.70
3518397126275Nonecode96Providing and laying vitrified floor tiles with thickness 9 10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry at the rate 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mmSqm1136.11136.163.19FalseNoneNoneFalseNoneFalse71790.1590
3518398126275Nonecode97WATER SUPPLY WORKS Of Savitha samja Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work Exposed on wallMtr333.9333.910.0FalseNoneNoneFalseNoneFalse3339.00
3518399126275Nonecode98Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the elected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.Cum508.2508.210.0FalseNoneNoneFalseNoneFalse5082.00
3518400126275Nonecode99Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and ommissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For:Mtr70.3570.3510.0FalseNoneNoneFalseNoneFalse703.50
3518401126275Nonecode100P/F PTMT BIB COCK Providing and fixing PTMT bib cock of approved quality and colour.15mm nominal bore, 86 mm long, weighing not less than 88 gNo167.48167.486.0FalseNoneNoneFalseNoneFalse1004.880
3518402126275Nonecode101P/F PTMT STOPCOCK CONCEALED Concealed stop cock, 15 mm nominal bore, 108 mm long, weighing not less than 108 gmsNo213.06213.062.0FalseNoneNoneFalseNoneFalse426.120
3518403126275Nonecode102P/F BRASS BALL VALVE Providing and fixing Brass full way valve gate with C.I. wheel of Approved quality (screwed end) : ( item no 13..4.1 ) page no 115 PWP. DSR 2023 24No581.94581.942.0FalseNoneNoneFalseNoneFalse1163.880
3518404126275Nonecode103P/F WASH BASIN Providing and fixing wash basin with C.I. brackets, 15 mm PTMT pillar cock, 32 mm PTMT waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm PTMT pillar cock. (item no 14.7B ) page no 125 PWP. DSR 2023 24No2410.82410.81.0FalseNoneNoneFalseNoneFalse2410.80
3518405126275Nonecode10415 mm nominal bore, 125 mm long foam flow, weighing not less than 120 gms13No332.84332.842.0FalseNoneNoneFalseNoneFalse665.680
3518406126275Nonecode105PVC connection pipeNo96.4696.461.0FalseNoneNoneFalseNoneFalse96.460
3518407126275Nonecode106SANITARY WORK WATER CLOSET EUROPEAN TYPE Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : ( item no 14.2 ) page no 123 PWP. DSR 2023 24Pan5079.05079.01.0FalseNoneNoneFalseNoneFalse5079.00
3518408126275Nonecode107WASTE PIPE Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe32 mm dia ( item no 14.28.2.1 ) page no 123 PWP. DSR 2023 24Each97.5297.521.0FalseNoneNoneFalseNoneFalse97.520
3518409126275Nonecode108WASTE PIPE RIGID Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. SEMI RIGID pipe32 mm dia ( item no 14.28.1.1 ) page no 123 PWP. DSR 2023 24Each80.5680.561.0FalseNoneNoneFalseNoneFalse80.560
3518410126275Nonecode109PVC PIPE Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN4, 110mm dia. ( item no 2.2) page no 134 VOLUME 5 PWP. DSR 2023 24Mtr287.26287.266.0FalseNoneNoneFalseNoneFalse1723.560
3518411126275Nonecode110Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base suooort for tank.Ltr9.459.451000.0FalseNoneNoneFalseNoneFalse9450.00
3518412126275Nonecode111WASTE PIPE RIGID Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe32 mm dia ( item no 14.28.2.1 ) page no 123 PWP. DSR 2023 24Each97.5297.521.0FalseNoneNoneFalseNoneFalse97.520
3518413126275Nonecode112Sinking of Borewell at savitha samaj Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M 15%, b) Above 30 M 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/ is to be deducted for Dry Borewell towards yield test. etc. complete (KPWD SR VOL V for the year 2023 24. I. No. 12.4 P.No. 140 )No5552.05552.01.0FalseNoneNoneFalseNoneFalse5552.00
3518414126275Nonecode113Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 0 to 50 Mtrs (KPWD SR VOL V for the year 2023 24. I. No. 12.1.1 P.No. 132 )Mtr388.5388.550.0FalseNoneNoneFalseNoneFalse19425.00
3518415126275Nonecode114Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 50 to 100 Mtrs (KPWD SR VOL V for the year 2023 24. I. No. 12.1.2 P.No. 132 )Mtr487.2487.250.0FalseNoneNoneFalseNoneFalse24360.00
3518416126275Nonecode115Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 100 to 150 Mtrs (KPWD SR VOL V for the year 2023 24. I. No. 12.1.3 P.No. 132 )Mtr517.65517.6510.0FalseNoneNoneFalseNoneFalse5176.50
3518417126275Nonecode116PVC pipes of 6 Kg/cm2 for 160mm (KPWD SR VOL V for the year 2023 24. Sl No. 649 P.No. A44 )Mtr441.0441.06.0FalseNoneNoneFalseNoneFalse2646.00
3518418126275Nonecode117PVC pipes of 6 Kg/cm2 for 110mm (KPWD SR VOL V for the year 2023 24. Sl No. 647 P.No. A44 )Mtr267.75267.75110.0FalseNoneNoneFalseNoneFalse29452.50
3518419126275Nonecode118Providing and laying at site of work MS casing caps as per IS 1239 (part II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part II) 1982 with all Amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in Charge ( (PWD UGD and water supply SR 2023 24 Volume V Item no.12.34 page no.143)Mtr172.2172.21.0FalseNoneNoneFalseNoneFalse172.20
3518420126275Nonecode119Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034 2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest ammendments 1.50 HP/1.1KW 20 STG (PWD UGD and water supply SR 2023 24 Volume V Item no.13.7.7 page no.150)No19128.919128.91.0FalseNoneNoneFalseNoneFalse19128.90
3518421126275Nonecode120Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. (PWD UGD and water supply SR 2023 24 Volume V Item no.13.31 page no.155)Mtr42.042.0110.0FalseNoneNoneFalseNoneFalse4620.00
3518422126275Nonecode121Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. (PWD UGD and water supply SR 2023 24 Volume V Item no.13.32 page no.156)Job6825.06825.01.0FalseNoneNoneFalseNoneFalse6825.00
3518423126275Nonecode122Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694 1990 with ISI Mark and as per its latest amendments. 1x3x6 Sqm. (PWD UGD and water supply SR 2023 24 Volume V Item no.13.22.4 page no.154)Mtr194.25194.25115.0FalseNoneNoneFalseNoneFalse22338.750
3518424126275Nonecode123Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984 2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 (PWD UGD and water supply SR 2023 24 Volume V Item no.9.1.1 page no.95)Mtr198.45198.45105.0FalseNoneNoneFalseNoneFalse20837.250
3518425126275Nonecode124Supply and delivery at site of brand new best make non return valve as per IS 778/1984 with ISI Mark and as per its latest amendments (PWD UGD and water supply SR 2023 24 Volume V Item no.13.25.2 page no.154)No1627.51627.51.0FalseNoneNoneFalseNoneFalse1627.50
3518426126275Nonecode125Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL Direct Online Starter 2) S D Star Delta Starter etc. complete.Upto 3 HP pumps (PWD UGD and water supply SR 2023 24 Volume V Item no.13.24.1 page no.155)Each7875.07875.01.0FalseNoneNoneFalseNoneFalse7875.00
3518427126275Nonecode126Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer incharge of work. (PWD UGD and water supply SR 2023 24 Volume V Item no.13.34 page no.156)Job1522.51522.51.0FalseNoneNoneFalseNoneFalse1522.50
3518428126275Nonecode127Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets. (PWD UGD and water supply SR 2023 24 Volume V Item no.13.25 page no.155)Kvar577.5577.51.0FalseNoneNoneFalseNoneFalse577.50
3518429126275Nonecode128Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box. (PWD UGD and water supply SR 2023 24 Volume V Item no.13.26 page no.155)No1207.51207.51.0FalseNoneNoneFalseNoneFalse1207.50
3518430126275Nonecode129Labour charges for providing connection using insulated sheathed steel wire cable as per IS 1554/ 1988 with latest amendments from KPTCL pole to meter board unit, with all necessary materials ,tools and equipments,as per specificationswith testing of as per instructions of engineer incharge of work. 3.5 x 16 sqmm (PWD UGD and water supply SR 2023 24 Volume V Item no.13.35.2 page no.156)No168.0168.01.0FalseNoneNoneFalseNoneFalse168.00
17207876700001NoneNoneOther WorksConstrcution of Toilet for Physically disabled peoples in wadi town.1761941.93
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3518431126276Nonecode01Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.(ii) By Mechanical Means using DozerB In area of thorny jungleha508.2508.20.5FalseNoneNoneFalseNoneFalse254.10
3518432126276Nonecode02Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, trutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.Cum95.5595.558.64FalseNoneNoneFalseNoneFalse825.5520
3518433126276Nonecode03Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.Depth exceeding 1.5m, but not exceeding 3 mCum467.25467.2550.76FalseNoneNoneFalseNoneFalse23717.610
3518434126276Nonecode04Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum6288.456288.456.012FalseNoneNoneFalseNoneFalse37806.16140
3518435126276Nonecode05Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6971.116971.114.788FalseNoneNoneFalseNoneFalse33377.674680
3518436126276Nonecode06Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11566.811566.81.5264FalseNoneNoneFalseNoneFalse17655.563520
3518437126276Nonecode07Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10206.010206.01.584FalseNoneNoneFalseNoneFalse16166.3040
3518438126276Nonecode08Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.459.504FalseNoneNoneFalseNoneFalse63757.10880
3518439126276Nonecode09Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge.Sqm267.75267.7515.84FalseNoneNoneFalseNoneFalse4241.160
3518440126276Nonecode10Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.344.62FalseNoneNoneFalseNoneFalse12462.3660
3518441126276Nonecode11Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1375.51375.544.28FalseNoneNoneFalseNoneFalse60907.140
3518442126276Nonecode12Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having lock density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1159.21159.218.9599FalseNoneNoneFalseNoneFalse21978.316080
3518443126276Nonecode13Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCum6527.856527.850.1FalseNoneNoneFalseNoneFalse652.7850
3518444126276Nonecode14Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11138.411138.41.944FalseNoneNoneFalseNoneFalse21653.04960
3518445126276Nonecode15Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10442.2510442.253.06FalseNoneNoneFalseNoneFalse31953.2850
3518446126276Nonecode16Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm253.05253.0524.48FalseNoneNoneFalseNoneFalse6194.6640
3518447126276Nonecode17Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10442.2510442.251.152FalseNoneNoneFalseNoneFalse12029.4720
3518448126276Nonecode18Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400per rcentage and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per pecification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm857.85857.8521.6FalseNoneNoneFalseNoneFalse18529.560
3518449126276Nonecode19Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum103755.75103755.750.782FalseNoneNoneFalseNoneFalse81136.99650
3518450126276Nonecode20Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures )Sqm7816.27816.28.82FalseNoneNoneFalseNoneFalse68938.8840
3518451126276Nonecode21Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.Kg192.15192.1556.7FalseNoneNoneFalseNoneFalse10894.9050
3518452126276Nonecode22Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement ortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever equired smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm389.55389.5549.86FalseNoneNoneFalseNoneFalse19422.9630
3518453126276Nonecode23Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, uring complete as per specifications and as per directions of Engineer-in-charge.Sqm253.05253.0580.16FalseNoneNoneFalseNoneFalse20284.4880
3518454126276Nonecode24Providing and laying red oxide flooring 40 mm thick, with an under layer of 30mm thick M-15 cement concrete and top layer of 10mm thick plaster with 1:3 cement mortar mixed with red oxide finished with floating coat of neat cement mixed with red oxide ( mix of same proportion ) , including cost of materials, labour, curing, complete as per specifications.Sqm825.3825.316.64FalseNoneNoneFalseNoneFalse13732.9920
3518455126276Nonecode25Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement ortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete.Sqm1161.31161.365.76FalseNoneNoneFalseNoneFalse76367.0880
3518456126276Nonecode26Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per pecifications and as per directions of Engineer in charge.Sqm105.0105.074.34FalseNoneNoneFalseNoneFalse7805.70
3518457126276Nonecode27Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per pecifications and as per directions of Engineer-in-charge.Sqm133.35133.3549.86FalseNoneNoneFalseNoneFalse6648.8310
3518458126276Nonecode28Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to move all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm186.9186.949.86FalseNoneNoneFalseNoneFalse9318.8340
3518459126276Nonecode29Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineerin- charge.Sqm27.327.349.86FalseNoneNoneFalseNoneFalse1361.1780
3518460126276Nonecode30Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter ncluding preparing the surface even and sand paper smooth, cost of materials, labour complete as per pecifications and as per directions of Engineer-in-charge.Sqm120.75120.755.4FalseNoneNoneFalseNoneFalse652.050
3518461126276Nonecode31Supplying, Fitting and Placing TMT Fe 500 & above Reinforcement in Foundation / Substructure Superstructure complete as per Drawing and Technical Specifications.Tonne90754.6590754.651.542FalseNoneNoneFalseNoneFalse139943.67030
3518462126276Nonecode32Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other ppurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) 2.1.4 Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCum6527.856527.852.376FalseNoneNoneFalseNoneFalse15510.17160
3518463126276Nonecode33Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the ngineerin- Charge.)Kg192.15192.15423.36FalseNoneNoneFalseNoneFalse81348.6240
3518464126276Nonecode34Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-chargeSqm333.9333.921.42FalseNoneNoneFalseNoneFalse7152.1380
3518465126276Nonecode35Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per anufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.12.55.2 -do- with one side prelamCum2142.02142.021.42FalseNoneNoneFalseNoneFalse45881.640
3518466126276Nonecode36Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameterMtr305.55305.5546.0FalseNoneNoneFalseNoneFalse14055.30
3518467126276Nonecode37Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, if c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipesMtr397.95397.9540.0FalseNoneNoneFalseNoneFalse15918.00
3518468126276Nonecode38Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, if c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipesMtr584.85584.8540.0FalseNoneNoneFalseNoneFalse23394.00
3518469126276Nonecode39Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required 14.2.1 W.C. pan with ISI marked white solid plastic seat and lidEach5079.95079.96.0FalseNoneNoneFalseNoneFalse30479.40
3518470126276Nonecode40Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cisternEach4676.74676.74.0FalseNoneNoneFalseNoneFalse18706.80
3518471126276Nonecode41Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 14.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar tapsEach3236.13236.14.0FalseNoneNoneFalseNoneFalse12944.40
3518472126276Nonecode42Providing and fixing brass stop cock of approved quality : 13.3.2 20 mm nominal boreEach320.25320.258.0FalseNoneNoneFalseNoneFalse2562.00
3518473126276Nonecode43Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 13.5.3 25 mm nominal boreEach348.6348.64.0FalseNoneNoneFalseNoneFalse1394.40
3518474126276Nonecode44Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base suooort for tank.Ltr9.459.452000.0FalseNoneNoneFalseNoneFalse18900.00
3518475126276Nonecode45Providing and fixing unplasticised PVC connection pipe with brass unions : 45 cm length 13.8.2.1 15 mm nominal boreNo95.5595.554.0FalseNoneNoneFalseNoneFalse382.20
3518476126276Nonecode46Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.No1281.01281.04.0FalseNoneNoneFalseNoneFalse5124.00
3518477126276Nonecode47Providing and fixing 100 mm sand cast Iron grating for gully trap.Each49.3549.354.0FalseNoneNoneFalseNoneFalse197.40
3518478126276Nonecode48Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth Page No.6 Item No. 1.5.1 KPWD. Volumn -1 DSR 2023-24Cum313.95313.95434.43FalseNoneNoneFalseNoneFalse136389.29850
3518479126276Nonecode49Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 3.5 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Non modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8367.458367.452.484FalseNoneNoneFalseNoneFalse20784.74580
3518480126276Nonecode50Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm404.25404.2537.92FalseNoneNoneFalseNoneFalse15329.160
3518481126276Nonecode51Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. itm.no 17.12 Page No.152 KPWD. Volumn -2 DSR 2023-24Sqm974.4974.44.1334FalseNoneNoneFalseNoneFalse4027.584960
3518482126276Nonecode52Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe32 mm dia ( item no 14.28.2.1 ) page no 123 PWP. DSR 2023-24Each96.696.64.0FalseNoneNoneFalseNoneFalse386.40
3518483126276Nonecode53Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15per rcentage, b) Above 30 M - 30per rcentage (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. etc. complete (KPWD SR VOL V for the year 2023-24. I. No. 12.4 P.No. 140 )No5552.45552.42.0FalseNoneNoneFalseNoneFalse11104.80
3518484126276Nonecode54Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10per rcentage for every 50m depth) Borewell depth of 0 to 50 Mtrs (KPWD SR VOL V for the year 2023-24. I. No. 12.1.1 P.No. 132 )Mtr388.5388.5100.0FalseNoneNoneFalseNoneFalse38850.00
3518485126276Nonecode55Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10per rcentage for every 50m depth) Borewell depth of 50 to 100 Mtrs (KPWD SR VOL V for the year 2023-24. I. No. 12.1.2 P.No. 132 )Mtr487.2487.2100.0FalseNoneNoneFalseNoneFalse48720.00
3518486126276Nonecode56Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10per rcentage for every 50m depth) Borewell depth of 100 to 150 Mtrs (KPWD SR VOL V for the year 2023-24. I. No. 12.1.3 P.No. 132 )Mtr517.65517.6520.0FalseNoneNoneFalseNoneFalse10353.00
3518487126276Nonecode57PVC pipes of 6 Kg/cm2 for 160mm (KPWD SR VOL V for the year 2023-24. Sl No. 649 P.No. A44 )Mtr441.0441.012.0FalseNoneNoneFalseNoneFalse5292.00
3518488126276Nonecode58PVC pipes of 6 Kg/cm2 for 110mm (KPWD SR VOL V for the year 2023-24. Sl No. 647 P.No. A44 )Mtr267.75267.75220.0FalseNoneNoneFalseNoneFalse58905.00
3518489126276Nonecode59Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all Amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in Charge ( (PWD UGD and water supply SR 2023-24 Volume - V Item no.12.34 page no.143)Mtr172.2172.22.0FalseNoneNoneFalseNoneFalse344.40
3518490126276Nonecode60Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest ammendments 1.50 HP/1.1KW 20 STG (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.7.7 page no.150)No19128.919128.92.0FalseNoneNoneFalseNoneFalse38257.80
3518491126276Nonecode61Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.31 page no.155)Mtr42.042.0220.0FalseNoneNoneFalseNoneFalse9240.00
3518492126276Nonecode62Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.32 page no.156)Job6825.06825.02.0FalseNoneNoneFalseNoneFalse13650.00
3518493126276Nonecode63Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x6 Sqm. (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.22.4 page no.154)Mtr194.25194.25230.0FalseNoneNoneFalseNoneFalse44677.50
3518494126276Nonecode64Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 (PWD UGD and water supply SR 2023-24 Volume - V Item no.9.1.1 page no.95)Mtr198.45198.45210.0FalseNoneNoneFalseNoneFalse41674.50
3518495126276Nonecode65Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.25.2 page no.154)No1627.51627.52.0FalseNoneNoneFalseNoneFalse3255.00
3518496126276Nonecode66Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete.Upto 3 HP pumps (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.24.1 page no.155)Each7875.07875.02.0FalseNoneNoneFalseNoneFalse15750.00
3518497126276Nonecode67Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer incharge of work. (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.34 page no.156)Job1522.51522.52.0FalseNoneNoneFalseNoneFalse3045.00
3518498126276Nonecode68Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets. (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.25 page no.155)Kvar577.5577.52.0FalseNoneNoneFalseNoneFalse1155.00
3518499126276Nonecode69Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box. (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.26 page no.155)No1207.51207.52.0FalseNoneNoneFalseNoneFalse2415.00
3518500126276Nonecode70Labour charges for providing connection using insulated sheathed steel wire cable as per IS 1554/ 1988 with latest amendments from KPTCL pole to meter board unit, with all necessary materials ,tools and equipments,as per specificationswith testing of as per instructions of engineer incharge of work. 3.5 x 16 sqmm (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.35.2 page no.156)No168.0168.02.0FalseNoneNoneFalseNoneFalse336.00
3518501126276Nonecode71Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20mm dia 2mm thick.Mtr69.069.060.0FalseNoneNoneFalseNoneFalse4140.00
3518502126276Nonecode72Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25mm dia 2mm thick.Mtr81.081.060.0FalseNoneNoneFalseNoneFalse4860.00
3518503126276Nonecode73Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 32mm dia 2.5mm thick.Mtr106.0106.060.0FalseNoneNoneFalseNoneFalse6360.00
3518504126276Nonecode74Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20mm dia 2mm thickMtr68.068.020.0FalseNoneNoneFalseNoneFalse1360.00
3518505126276Nonecode75Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thickMtr79.079.060.0FalseNoneNoneFalseNoneFalse4740.00
3518506126276Nonecode76Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 32mm dia 2.5mm thickMtr99.099.060.0FalseNoneNoneFalseNoneFalse5940.00
3518507126276Nonecode77Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, screws at an interval of 300mm …. etc. as required.25mmMtr35.035.050.0FalseNoneNoneFalseNoneFalse1750.00
3518508126276Nonecode78Supplying And Fixing Metal Fan Box with Round HookNo160.0160.04.0FalseNoneNoneFalseNoneFalse640.00
3518509126276Nonecode79Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.3.2 1.5 mm2Mtr26.026.060.0FalseNoneNoneFalseNoneFalse1560.00
3518510126276Nonecode80Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.3.3 2.5 mm2Mtr42.042.060.0FalseNoneNoneFalseNoneFalse2520.00
3518511126276Nonecode81Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.3.4 4 mm2Mtr63.063.060.0FalseNoneNoneFalseNoneFalse3780.00
3518512126276Nonecode82Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.3.5 6 mm2Mtr92.092.060.0FalseNoneNoneFalseNoneFalse5520.00
3518513126276Nonecode83Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 2.3.6 10 mm2Mtr167.0167.060.0FalseNoneNoneFalseNoneFalse10020.00
3518514126276Nonecode84Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.1 1-3 WayEach138.0138.02.0FalseNoneNoneFalseNoneFalse276.00
3518515126276Nonecode85Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.3 6 WayEach177.0177.02.0FalseNoneNoneFalseNoneFalse354.00
3518516126276Nonecode86Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.4 8 WayEach220.0220.02.0FalseNoneNoneFalseNoneFalse440.00
3518517126276Nonecode87Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.5 10-12 WayEach261.0261.02.0FalseNoneNoneFalseNoneFalse522.00
3518518126276Nonecode88Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.1 1 to 3 ModuleEach127.0127.02.0FalseNoneNoneFalseNoneFalse254.00
3518519126276Nonecode89Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.3 6 ModuleEach175.0175.02.0FalseNoneNoneFalseNoneFalse350.00
3518520126276Nonecode90Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.4 8 ModuleEach234.0234.02.0FalseNoneNoneFalseNoneFalse468.00
3518521126276Nonecode91Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.5 10-12 Module Each284.0284.02.0FalseNoneNoneFalseNoneFalse568.00
3518522126276Nonecode92Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.1 6A One Way Switch Each102.0102.02.0FalseNoneNoneFalseNoneFalse204.00
3518523126276Nonecode93Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.3 6A Three Way socket Each171.0171.02.0FalseNoneNoneFalseNoneFalse342.00
3518524126276Nonecode94Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.8 16A One Way Switch Each177.0177.02.0FalseNoneNoneFalseNoneFalse354.00
3518525126276Nonecode95Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. II - Double Door 5.18.6 4 Way SP & N Each1368.01368.02.0FalseNoneNoneFalseNoneFalse2736.00
3518526126276Nonecode96Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. II - Double Door 5.18.7 6 Way SP & N Each1102.01102.02.0FalseNoneNoneFalseNoneFalse2204.00
3518527126276Nonecode97Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 5.17.1 6-32 A SP Each415.0415.02.0FalseNoneNoneFalseNoneFalse830.00
3518528126276Nonecode98Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 5.17.7 6-32 A TPN Each1717.01717.02.0FalseNoneNoneFalseNoneFalse3434.00
3518529126276Nonecode99Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB ). The entire plug and socket shall be mounted in a thermoplastic / powder coated metal box & wired Completely. SP & N SP & N 5.45.2 20 A Each971.0971.02.0FalseNoneNoneFalseNoneFalse1942.00
3518530126276Nonecode100Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB ). The entire plug and socket shall be mounted in a thermoplastic / powder coated metal box & wired Completely. SP & N TP & N 5.45.3 20 A Each1340.01340.04.0FalseNoneNoneFalseNoneFalse5360.00
3518531126276Nonecode1011.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 32.11 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm) Km178973.0178973.00.04FalseNoneNoneFalseNoneFalse7158.920
3518532126276Nonecode102Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 1.06 35 to 95 SqmmKm31139.031139.00.1FalseNoneNoneFalseNoneFalse3113.90
3518533126276Nonecode103Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. 29.03 In Hard Soil Cum389.0389.014.0FalseNoneNoneFalseNoneFalse5446.00
3518534126276Nonecode104Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 Mtr Cum58.058.014.0FalseNoneNoneFalseNoneFalse812.00
3518535126276Nonecode105LED Indoor Supplying of .feet -PVC Batten with integrated LED tube . W with high quality diffuser with Life of 25000 burning hours & 70per rcentage lumen maintenance with CRI Greater then 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater then0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. 11.3.3 LED light fitting 1 x 4' - 36/40 W Each1269.01269.04.0FalseNoneNoneFalseNoneFalse5076.00
3518536126276Nonecode108Supply of round/square recess/surface mounted rolling type LED Down light with . W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70per rcentage lumen maintenance with CRI Greater then 80. Power Input: 220-240V @50/60Hz & Power factor Greater then0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition. 11.5.3 LED square or round down light 15-18W Each1324.01324.06.0FalseNoneNoneFalseNoneFalse7944.00
17207876710001NoneNoneOther WorksDevelopemtn of Sevalal temple in ward no 4 in wadi town.2113916.37
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3518537126277Nonecode01Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including TandP and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead By Mechanical means Dismantling Brick / Tile work / rubble masonry / pitching / etc by mechanical meansCum189.0189.04.8FalseNoneNoneFalseNoneFalse907.20
3518538126277Nonecode02Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting and stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage and other appurtenances required to complete the work.Depth exceeding 1.5m, but not exceeding 3 mCum467.25467.2551.84FalseNoneNoneFalseNoneFalse24222.240
3518539126277Nonecode03Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum6288.456288.452.59FalseNoneNoneFalseNoneFalse16287.08550
3518540126277Nonecode04Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7170.287170.289.8FalseNoneNoneFalseNoneFalse70268.7440
3518541126277Nonecode05Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11566.811566.84.195FalseNoneNoneFalseNoneFalse48522.7260
3518542126277Nonecode06Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10886.410886.40.4623FalseNoneNoneFalseNoneFalse5032.782720
3518543126277Nonecode07Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.339.45FalseNoneNoneFalseNoneFalse11018.3850
3518544126277Nonecode08Supplying, Fitting and Placing TMT Fe 500 and above Reinforcement in Foundation / Substructure Superstructure complete as per Drawing and Technical Specifications.Tonne90754.6590754.651.02FalseNoneNoneFalseNoneFalse92569.7430
3518545126277Nonecode09Providing and fixing self supported, ribbed. high quality, high grade (D:350 MPA Yst Min ), pre painted Galvalume steel roof sheet, coated with bare Galvalume coating AZ 150, at the rate 150 gms/Smtr 55PercentageAL.45PercentageZri) by hot qip process, of total coated thickness as specified for different spans with atolerance of 0.02 mm, according to technical specification confirming to A 792, with NCCA 11 1, or ECCA T 4 Pencil hardness Ha, NCCA standardSqm1365.01365.0116.58FalseNoneNoneFalseNoneFalse159131.70
3518546126277Nonecode10Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in Charge.Sqm142.8142.8582.9FalseNoneNoneFalseNoneFalse83238.120
3518547126277Nonecode11Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work.Cum8376.98376.913.565FalseNoneNoneFalseNoneFalse113632.64850
3518548126277Nonecode12Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in Charge.Kg154.35154.35508.714FalseNoneNoneFalseNoneFalse78520.00590
3518549126277Nonecode13Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per irections of the Engineer in Charge.Kg142.8142.8126.0FalseNoneNoneFalseNoneFalse17992.80
3518550126277Nonecode14Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, uring complete as per specifications and as per directions of Engineer in charge.Sqm253.05253.05277.1124FalseNoneNoneFalseNoneFalse70123.292820
3518551126277Nonecode15Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement ortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever equired smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in charge.Sqm389.55389.5560.1319FalseNoneNoneFalseNoneFalse23424.3816450
3518552126277Nonecode16Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm ominal size graded crushed coarse aggregatesSqm11138.411138.45.2916FalseNoneNoneFalseNoneFalse58939.957440
3518553126277Nonecode17Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per pecifications and as per directions of Engineer in charge.Sqm105.0105.0277.1124FalseNoneNoneFalseNoneFalse29096.8020
3518554126277Nonecode18Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per pecifications and as per directions of Engineer in charge.Sqm133.35133.35277.1124FalseNoneNoneFalseNoneFalse36952.938540
3518555126277Nonecode19Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied at the rate 1.43 ltr/10 m² over and including priming coat of exterior primer applied at the rate 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to move all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer in charge.Sqm186.9186.960.131FalseNoneNoneFalseNoneFalse11238.48390
3518556126277Nonecode20Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter ncluding preparing the surface even and sand paper smooth, cost of materials, labour complete as per pecifications and as per directions of Engineer in charge.Sqm120.75120.751027.5FalseNoneNoneFalseNoneFalse124070.6250
3518557126277Nonecode21Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer in charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in Charge.Mtr593.25593.2525.578FalseNoneNoneFalseNoneFalse15174.14850
3518558126277Nonecode22Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer in Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry at the rate 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete.Sqm1161.31161.3126.0FalseNoneNoneFalseNoneFalse146323.80
3518559126277Nonecode23Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesSqm6288.456288.4516.3125FalseNoneNoneFalseNoneFalse102580.3406250
3518560126277Nonecode24Toilet Block Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.(ii) By Mechanical Means using DozerB In area of thorny jungleSqm508.2508.20.25FalseNoneNoneFalseNoneFalse127.050
3518561126277Nonecode25Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering and leveling the ground for all works other than foundation and depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, trutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage and other appurtenances required to complete the work.Cum95.5595.554.32FalseNoneNoneFalseNoneFalse412.7760
3518562126277Nonecode26Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting and stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage and other appurtenances required to complete the work.Depth exceeding 1.5m, but not exceeding 3 mCum467.25467.2525.38FalseNoneNoneFalseNoneFalse11858.8050
3518563126277Nonecode27Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum6288.456288.453.0FalseNoneNoneFalseNoneFalse18865.350
3518564126277Nonecode28Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7348.327348.322.394FalseNoneNoneFalseNoneFalse17591.878080
3518565126277Nonecode29Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11566.811566.80.7632FalseNoneNoneFalseNoneFalse8827.781760
3518566126277Nonecode30Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10886.410886.40.792FalseNoneNoneFalseNoneFalse8622.02880
3518567126277Nonecode31Providing Size Stone masonry with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.454.752FalseNoneNoneFalseNoneFalse31878.55440
3518568126277Nonecode32Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer in charge.Sqm267.75267.757.92FalseNoneNoneFalseNoneFalse2120.580
3518569126277Nonecode33Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.322.31FalseNoneNoneFalseNoneFalse6231.1830
3518570126277Nonecode34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part I) 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1375.51375.522.14FalseNoneNoneFalseNoneFalse30453.570
3518571126277Nonecode35Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having lock density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part I) 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1159.21159.29.47FalseNoneNoneFalseNoneFalse10977.6240
3518572126277Nonecode36Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum6288.456288.450.045FalseNoneNoneFalseNoneFalse282.980250
3518573126277Nonecode37Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11138.411138.40.97FalseNoneNoneFalseNoneFalse10804.2480
3518574126277Nonecode38Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11138.411138.41.224FalseNoneNoneFalseNoneFalse13633.40160
3518575126277Nonecode39Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in charge.Sqm253.05253.0512.24FalseNoneNoneFalseNoneFalse3097.3320
3518576126277Nonecode40Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11138.411138.40.432FalseNoneNoneFalseNoneFalse4811.78880
3518577126277Nonecode41Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as specidfication and as per directionsof Engineer in chargeSqm11138.411138.40.43FalseNoneNoneFalseNoneFalse4789.5120
3518578126277Nonecode42Providing and fixing factory made UPVC Door Frame made of UPVC extruded sections having an overall dimension as below (tolerance +/ 1mm ) with wall thickness 2.00mm (+/ 2mm), corners of the door frames to be jointed with galvanised brackets and stainless steel screws,joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanised MS Tube of size 19mm X 19mm and 1mm (+/ 1mm) wall thickness and 3 Nos stainless steel hinges fixed to the frame complete as per manufacturer specification and direction of Engineer in charge.Sqm250.95250.9521.0FalseNoneNoneFalseNoneFalse5269.950
3518579126277Nonecode43Providing and fixing of openable Door made out of multi chambered UPVC (matching to RAL 9016) sections and with minimum Ti02 (Titanium Doxide) at 6PHR with TPV (Thermo Plastic Vulcanised) and lead free with gasket grey color having isolated drainage and reinforced with Galvanised Iron profile through out the openable frame. The frame having overall size of 60mm X 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm X 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm X 34mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge and multi point locking system with handle. Wall thickness of frame and sash shall be of 2mm 2.50mm. Maximum possible size 900mm X 2400mm. (The cost is inclusive of all fixtures and separate charge for minor TandP's shall not be made)Sqm6557.256557.2510.71FalseNoneNoneFalseNoneFalse70228.14750
3518580126277Nonecode44Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.Kg192.15192.1528.35FalseNoneNoneFalseNoneFalse5447.45250
3518581126277Nonecode45Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement ortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever equired smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in charge.Sqm389.55389.5524.93FalseNoneNoneFalseNoneFalse9711.48150
3518582126277Nonecode46Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, uring complete as per specifications and as per directions of Engineer in charge.Sqm253.05253.0540.08FalseNoneNoneFalseNoneFalse10142.2440
3518583126277Nonecode47Providing and laying red oxide flooring 40 mm thick, with an under layer of 30mm thick M 15 cement concrete and top layer of 10mm thick plaster with 1:3 cement mortar mixed with red oxide finished with floating coat of neat cement mixed with red oxide ( mix of same proportion ) , including Cost of materials, labour, curing, complete as per specifications.Sqm825.3825.38.32FalseNoneNoneFalseNoneFalse6866.4960
3518584126277Nonecode48Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer in Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement ortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry at the rate 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete.Sqm1161.31161.318.68FalseNoneNoneFalseNoneFalse21693.0840
3518585126277Nonecode49Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per pecifications and as per directions of Engineer in charge.Sqm105.0105.037.17FalseNoneNoneFalseNoneFalse3902.850
3518586126277Nonecode50Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per pecifications and as per directions of Engineer in charge.Sqm133.35133.3524.93FalseNoneNoneFalseNoneFalse3324.41550
3518587126277Nonecode51Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied at the rate 1.43 ltr/10 m² over and including priming coat of exterior primer applied at the rate 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to move all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer in charge.Sqm186.9186.924.93FalseNoneNoneFalseNoneFalse4659.4170
3518588126277Nonecode52Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineerin charge.Sqm27.327.324.93FalseNoneNoneFalseNoneFalse680.5890
3518589126277Nonecode53Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter ncluding preparing the surface even and sand paper smooth, cost of materials, labour complete as per pecifications and as per directions of Engineer in charge.Sqm120.75120.752.7FalseNoneNoneFalseNoneFalse326.0250
3518590126277Nonecode54Supplying, Fitting and Placing TMT Fe 500 and above Reinforcement in Foundation / Substructure Superstructure complete as per Drawing and Technical Specifications.Tonne90754.6590754.650.74FalseNoneNoneFalseNoneFalse67158.4410
3518591126277Nonecode55Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other ppurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork shall be paid separately) 2.1.4 Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCum6527.856527.851.188FalseNoneNoneFalseNoneFalse7755.08580
3518592126277Nonecode56Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the ngineerin Charge.)Kg192.15192.15211.68FalseNoneNoneFalseNoneFalse40674.3120
3518593126277Nonecode57Providing and fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners and jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification and direction of Engineer in chargeSqm333.9333.910.71FalseNoneNoneFalseNoneFalse3576.0690
3518594126277Nonecode58Providing and fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top and bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet and 30x50mm wide to form stiles and 5mm thick and 75mm wide Prelaminated PVC Sheets for top rail, lock rail and bottom rail on either side and 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail and bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles and rails with PVC Designer beading on either side and joined together with solvent cement adhesive etc., Complete as per anufacturers specification and direction of Engineer in charge fixed to frames with 3 nos of 75mm Aluminium hinges.12.55.2 do with one side prelamCum2142.02142.010.71FalseNoneNoneFalseNoneFalse22940.820
3518595126277Nonecode59Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameterMtr305.55305.5530.0FalseNoneNoneFalseNoneFalse9166.50
3518596126277Nonecode60Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, if c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipesMtr397.95397.9515.0FalseNoneNoneFalseNoneFalse5969.250
3518597126277Nonecode61Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, if c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipesMtr584.85584.8515.0FalseNoneNoneFalseNoneFalse8772.750
3518598126277Nonecode62Providing and fixing Water Closet squatting pan (Indian type W.C. Pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. Pan of size 580x440 mm with integral type foot restsEach5128.25128.22.0FalseNoneNoneFalseNoneFalse10256.40
3518599126277Nonecode63Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 14.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar tapsEach3236.13236.12.0FalseNoneNoneFalseNoneFalse6472.20
3518600126277Nonecode64Providing and fixing brass stop cock of approved quality : 13.3.2 20 mm nominal boreEach320.25320.255.0FalseNoneNoneFalseNoneFalse1601.250
3518601126277Nonecode65Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 13.5.3 25 mm nominal boreEach348.6348.63.0FalseNoneNoneFalseNoneFalse1045.80
3518602126277Nonecode66Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base suooort for tank.Ltr9.459.451000.0FalseNoneNoneFalseNoneFalse9450.00
3518603126277Nonecode67Providing and fixing unplasticised PVC connection pipe with brass unions : 45 cm length 13.8.2.1 15 mm nominal boreNo95.5595.553.0FalseNoneNoneFalseNoneFalse286.650
3518604126277Nonecode68Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.No1281.01281.02.0FalseNoneNoneFalseNoneFalse2562.00
3518605126277Nonecode69Providing and fixing 100 mm sand cast Iron grating for gully trap.Each49.3549.352.0FalseNoneNoneFalseNoneFalse98.70
3518606126277Nonecode70Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting and stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage and other appurtenances required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth Page No.6 Item No. 1.5.1 KPWD. Volumn 1 DSR 2021 22Cum313.95313.95217.215FalseNoneNoneFalseNoneFalse68194.649250
3518607126277Nonecode71Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 3.5 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Non modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work.Cum8367.458367.451.242FalseNoneNoneFalseNoneFalse10392.37290
3518608126277Nonecode72Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in charge.Sqm404.25404.2518.96FalseNoneNoneFalseNoneFalse7664.580
3518609126277Nonecode73Providing and laying 100mm thick pre cast cover slabs over drains and Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm 3ply wired steel at the rate 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. itm.no 17.12 Page No.152 KPWD. Volumn 2 DSR 2023 24Sqm974.4974.42.0667FalseNoneNoneFalseNoneFalse2013.792480
3518610126277Nonecode74Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe32 mm dia ( item no 14.28.2.1 ) page no 123 PWP. DSR 2021 22Each96.696.62.0FalseNoneNoneFalseNoneFalse193.20
3518611126277Nonecode75Electrical Work Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20mm dia 2mm thick.Mtr69.069.046.0FalseNoneNoneFalseNoneFalse3174.00
3518612126277Nonecode76Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25mm dia 2mm thick.Mtr81.081.046.0FalseNoneNoneFalseNoneFalse3726.00
3518613126277Nonecode77Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 32mm dia 2.5mm thick.Mtr100.0100.046.0FalseNoneNoneFalseNoneFalse4600.00
3518614126277Nonecode78Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20mm dia 2mm thickMtr68.068.046.0FalseNoneNoneFalseNoneFalse3128.00
3518615126277Nonecode79Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thickMtr79.079.046.0FalseNoneNoneFalseNoneFalse3634.00
3518616126277Nonecode80Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 32mm dia 2.5mm thickMtr99.099.060.0FalseNoneNoneFalseNoneFalse5940.00
3518617126277Nonecode81Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, screws at an interval of 300mm …. etc. as required. 25mmMtr35.035.090.0FalseNoneNoneFalseNoneFalse3150.00
3518618126277Nonecode82Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Short point upto 3m from tapping point to out let via switch boxPoint269.0269.06.0FalseNoneNoneFalseNoneFalse1614.00
3518619126277Nonecode83Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Medium point above 3m upto 6m from tapping point to out let via switch boxPoint379.0379.05.0FalseNoneNoneFalseNoneFalse1895.00
3518620126277Nonecode84Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Long point above 6m upto 10m from tapping point to out let via switch boxPoint555.0555.05.0FalseNoneNoneFalseNoneFalse2775.00
3518621126277Nonecode85Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Two outlet in a row, above 3m upto 6m from tapping point to out let via switchesPoint677.0677.05.0FalseNoneNoneFalseNoneFalse3385.00
3518622126277Nonecode86Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Three outlet in a row, above 6m upto 10m from tapping point to out let via switches boxPoint989.0989.04.0FalseNoneNoneFalseNoneFalse3956.00
3518623126277Nonecode87Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:confirming to latest amendments. 1.5 mm2Mtr26.026.070.0FalseNoneNoneFalseNoneFalse1820.00
3518624126277Nonecode88Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:confirming to latest amendments.2.5 mm2Mtr42.042.060.0FalseNoneNoneFalseNoneFalse2520.00
3518625126277Nonecode89Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:confirming to latest amendments. 4 mm2Mtr63.063.060.0FalseNoneNoneFalseNoneFalse3780.00
3518626126277Nonecode90Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:confirming to latest amendments.6 mm2Mtr87.087.060.0FalseNoneNoneFalseNoneFalse5220.00
3518627126277Nonecode91Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:confirming to latest amendments 10 mm2Mtr167.0167.040.0FalseNoneNoneFalseNoneFalse6680.00
3518628126277Nonecode92Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3 WayEach159.0159.08.0FalseNoneNoneFalseNoneFalse1272.00
3518629126277Nonecode93Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6 WayEach220.0220.06.0FalseNoneNoneFalseNoneFalse1320.00
3518630126277Nonecode94Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 ModuleEach161.0161.05.0FalseNoneNoneFalseNoneFalse805.00
3518631126277Nonecode95Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 ModuleEach234.0234.04.0FalseNoneNoneFalseNoneFalse936.00
3518632126277Nonecode96LED Indoor Supplying of .feet PVC Batten with integrated LED tube . W with high quality diffuser with Life of 25000 burning hours and 70Percentage lumen maintenance with CRI Smaller than 80. Power Input: 220 240Vat the rate 50/60Hz and Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4 36/40 WEach1269.01269.04.0FalseNoneNoneFalseNoneFalse5076.00
3518633126277Nonecode97Supply of round/square recess/surface mounted rolling type LED Down light with . W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector and has swivelling unit of aluminium die cast eye ball and LED Lamp position retained by circular wire spring, with Life of 25000 burning hours and 70Percentage lumen maintenance with CRI Smaller than 80. Power Input: 220 240V at the rate50/60Hz and Power factor Smaller than0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition. LED square or round down light 15 18WEach1324.01324.06.0FalseNoneNoneFalseNoneFalse7944.00
3518634126277Nonecode98LED Down light Supplying of recess mounting non integrated type LED down light. W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clA, LED of Power/COB with CCT 6500 degree K, CRISmaller than 70Percentage. efficacy Smaller than100 lumen per W, 120degree beam spread, lifeSmaller than 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 and LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF Smaller than 0.95, power loss shouldGreater then 5Percentage of lamp Wage, short circuit and open circuit protection to be integrated in the circuit, THD less than 20Percentage, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited aboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.15 18WEach1671.01671.010.0FalseNoneNoneFalseNoneFalse16710.00
3518635126277Nonecode99Supplying and fixing of round or oblong type bulk head fitting glass coverEach68.068.06.0FalseNoneNoneFalseNoneFalse408.00
3518636126277Nonecode100Fixing all types and all capacities fluorescent/false ceiling/spot light/ CFL fittings indoor on the wall/ ceiling/rafters/girders using 23/0.0076'' twin PVC insulated wires, required nos of round blocks and clamps (if required) On wall/ ceiling / Rafter / GirdersEach122.0122.010.0FalseNoneNoneFalseNoneFalse1220.00
3518637126277Nonecode101Fixing a ceiling/wall mounting fan of all capacities and all types with necessary clamps and S hook made out of 15mm dia MS rod, with 5 amps ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality mounted on a suitable size wooden board and wired complete.Each315.0315.04.0FalseNoneNoneFalseNoneFalse1260.00
3518638126277Nonecode102Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.Each707.0707.04.0FalseNoneNoneFalseNoneFalse2828.00
3518639126277Nonecode103Supplying . amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100 A 4 x 30 x 6 mm Aluminium StripsMtr2465.02465.02.0FalseNoneNoneFalseNoneFalse4930.00
3518640126277Nonecode104Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mmMtr305.0305.05.0FalseNoneNoneFalseNoneFalse1525.00
3518641126277Nonecode105Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 50 x 100 x 50 x 6 mm C channelMtr680.0680.06.0FalseNoneNoneFalseNoneFalse4080.00
3518642126277Nonecode106Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS 13947. (Icu=100Percentage lcs). In 4P MCCB, all Poles should have protection for Short Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. THREE Pole 100 A 25 kAEach6086.06086.04.0FalseNoneNoneFalseNoneFalse24344.00
3518643126277Nonecode107Supplying, fixing and wiring Residual current circuit breaker (RCCB)240/450V upto 300mA sensitivity on existing wood/ panel board. 32 40 A 4 poleEach5147.05147.02.0FalseNoneNoneFalseNoneFalse10294.00
3518644126277Nonecode108Supplying and fixing of Shunt trip suitable for MCCB.CBCT.Each1703.01703.02.0FalseNoneNoneFalseNoneFalse3406.00
3518645126277Nonecode109Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each9255.09255.01.0FalseNoneNoneFalseNoneFalse9255.00
3518646126277Nonecode110Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each515.0515.02.0FalseNoneNoneFalseNoneFalse1030.00
3518647126277Nonecode111Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound.Each562.0562.02.0FalseNoneNoneFalseNoneFalse1124.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17207876700000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17207876700000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17207876700000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneMinimum financial turnover (Civil engineering construction works) not less than two time the annual payments from the contract (Rs.95.85 Lakhs)OthersMinimum financial turnover
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Minimum financial turnover
NoneNoneNoneNoneSatisfactorily completed (atleast 90%) as prime contractor at-least one similat work of vale not less then Rs. 76.68 Lakhs(80% of the estimated cost of tender)OthersSatisfactorily completed (
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Satisfactorily completed
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
To qualify for award of this contract each tenderer in his name should have in the last five years period achieved in the last two years at least two financial years an average annual financial turnover of Rs.95.85 Lakhs.TrueTechnical Bid
Eligible Registered PWD Contractor.TrueTechnical Bid
Similar Nature of Work Done Certificate achieved at least 50 Percent of Estimate Cost 47.92 Lakhs.TrueTechnical Bid
IT return Certificate Last 3 years.TrueTechnical Bid
GST Registration Certificate and PAN Card.TrueTechnical Bid
Liquid assets and or availability of credit facilities of not less than Rs 28.75 Lakhs.TrueTechnical Bid
As per the KW-3 Tender document.TrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1720788544000
version0
createdDateNone
modifiedDateNone
blockNumberROOM NO-10 DUDC MINI VIDHAN SOUDA KALABURAG IDISTRICT
streetNone
cityKALABURAGI
stateKarnataka
pin585102
tenderRecallDTONone