createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1721120769873
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd36125.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose30-07-2024 16:30:00
tenderQueryClose29-07-2024 11:00:00
technicalBidOpen31-07-2024 16:31:00
publishedDate16-07-2024 17:55:10
publishedByPostCMC_MCOM_RB
publishedByUserKPE12021 - JAGADISH S ITI
bidValidityPeriod120
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonV P Hipparagi
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber8792301402
tenderSupplierListNone
tenderSchedule
createdTs1721120769909
version6
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/OW/WORK_INDENT21395
titleCMC Rabkavi-Banahatti State Finance Commission CA Grant Scheme 2024-25 Package No.5
descriptionConstruction of record room in Municipal Office premises at CMC Rabkavi-Banahatti
categoryWORKS
categoryTextWorks
ecv1445000.00
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2217
locationNameDMA City Municipal Council Rabkavi Banhatti
provisionalAmount1445000.0
groupOverheadTotal220530.81
fileNumberCMCRB/SFCCA/2024/25/05
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17211207700000NoneNoneOther WorksConstruction of record room in Municipal Office premises at CMC Rabkavi-Banahatti1224469.19
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3533824127288Nonecode01Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Depth exceeding 1.5 m, but not exceeding 3mCum437.75437.7551.2595FalseNoneNoneFalseNoneFalse22438.8461250
3533825127288Nonecode02Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement & formwork shall be paid separatelyCum6168.676168.679.44FalseNoneNoneFalseNoneFalse58232.24480
3533826127288Nonecode03Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement & formwork to be paid separately M25 Design Mix Using 20 mm nominal size graded crushed coarseaggregatesCum7048.177048.175.76FalseNoneNoneFalseNoneFalse40597.45920
3533827127288Nonecode04Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement, dowel bars & formwork to be paid separately M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregateCum11982.0911982.093.56FalseNoneNoneFalseNoneFalse42656.24040
3533828127288Nonecode05Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement, dowel bars & formwork to be paid separately M25 Design Mix Using 20 mm nominal size graded crushed coarse Plinth BeamaggregateCum10572.4410572.442.3FalseNoneNoneFalseNoneFalse24316.6120
3533829127288Nonecode052ChejjasCum10220.0210220.020.26FalseNoneNoneFalseNoneFalse2657.20520
3533830127288Nonecode053LintelsCum11277.2611277.260.92FalseNoneNoneFalseNoneFalse10375.07920
3533831127288Nonecode054Roof BeamCum11277.2611277.262.36FalseNoneNoneFalseNoneFalse26614.33360
3533832127288Nonecode055Roof SlabCum10572.4410572.449.88FalseNoneNoneFalseNoneFalse104455.70720
3533833127288Nonecode06Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 1 cement : 6 coarse sandCum6580.676580.6726.24FalseNoneNoneFalseNoneFalse172676.78080
3533834127288Nonecode07Filling approved earth excluding rock in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 mCum445.99445.99141.2595FalseNoneNoneFalseNoneFalse63000.3244050
3533835127288Nonecode08Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingt92140.7192140.712.34FalseNoneNoneFalseNoneFalse215609.26140
3533836127288Nonecode09Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 Part - I - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specificationsCum1349.31349.367.82FalseNoneNoneFalseNoneFalse91509.5260
3533837127288Nonecode10Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 1 cement: 3 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm332.69332.6945.0FalseNoneNoneFalseNoneFalse14971.050
3533838127288Nonecode11Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 1 cement: 6 fine sand including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm287.37287.3796.48FalseNoneNoneFalseNoneFalse27725.45760
3533839127288Nonecode12Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 1 cement : 5 coarse sand finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 1 cement : 6 fine sand to brick masonry including ounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge Ground FloorSqm382.13382.13149.91FalseNoneNoneFalseNoneFalse57285.10830
3533840127288Nonecode13Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in chargeSqm103.0103.0141.48FalseNoneNoneFalseNoneFalse14572.440
3533841127288Nonecode14Wall painting with premium acrylic emulsion paint of interior grade, having VOC Volatile Organic Compound content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in chargSqm113.3113.3141.48FalseNoneNoneFalseNoneFalse16029.6840
3533842127288Nonecode15Finishing walls with Acrylic Smooth exterior paint of required shade :New work Two coat applied at 1.67 ltr/10 m² over and including priming coat of exterior primer applied at 2.20 kg/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm179.22179.22149.91FalseNoneNoneFalseNoneFalse26866.87020
3533843127288Nonecode16Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves excluding cost of cement concrete and side clamps , but including cost of materials, labour, usage charges complete as per specificationsCum127928.06127928.060.07FalseNoneNoneFalseNoneFalse8954.96420
3533844127288Nonecode17Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specificationsEach1046.481046.481.0FalseNoneNoneFalseNoneFalse1046.480
3533845127288Nonecode18Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. excluding cost of fixturesSqm7103.917103.912.88FalseNoneNoneFalseNoneFalse20459.26080
3533846127288Nonecode19Door Fixtures-Providing and fixing bright finished brass handles with screws etc. completeBrass handles 125 mm with plate 175x32 mmEach256.47256.472.0FalseNoneNoneFalseNoneFalse512.940
3533847127288Nonecode20Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. completeEach56.6556.653.0FalseNoneNoneFalseNoneFalse169.950
3533848127288Nonecode21Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. completeEach1083.561083.561.0FalseNoneNoneFalseNoneFalse1083.560
3533849127288Nonecode22Providing and fixing aluminium tower bolts, ISI marked, anodised anodic coating not less than grade AC 10 as per IS : 1868 transparent or dyed to required colour or shade, with necessary screws etc. completeEach133.9133.92.0FalseNoneNoneFalseNoneFalse267.80
3533850127288Nonecode23Providing and fixing of 2 track x 2 panel sliding windows made out of multi chambered UPVC Matching to RAL 9016 sections and with minimum TiO2 Titanium Dioxide at 6 PHR with TPE Thermo Plastic Elastomer and lead free, gaskets grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware and single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. The cost is inclusive of all fixtures and separate charges for minor T and P s shall not be madeSqm5173.695173.695.76FalseNoneNoneFalseNoneFalse29800.45440
3533851127288Nonecode24Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etcKg188.49188.4957.6FalseNoneNoneFalseNoneFalse10857.0240
3533852127288Nonecode25Applying priming coat: With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm59.7459.742.0625FalseNoneNoneFalseNoneFalse123.213750
3533853127288Nonecode26Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm118.45118.457.8225FalseNoneNoneFalseNoneFalse926.5751250
3533854127288Nonecode27Providing and laying vitrified floor tiles in different sizes thickness to be specified by the manufacturer with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 1 cement : 4 coarse sand, jointing with grey cement slurry at 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 500x500 mmSqm1114.461114.4645.0FalseNoneNoneFalseNoneFalse50150.70
3533855127288Nonecode28Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specificationsSqm1492.471492.472.8FalseNoneNoneFalseNoneFalse4178.9160
3533856127288Nonecode29Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 Part - I- 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications Ground FloorSqm1137.121137.1221.69FalseNoneNoneFalseNoneFalse24664.13280
3533857127288Nonecode30ELECTRIFICATION Supplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outlet point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switchEach285.0285.02.0FalseNoneNoneFalseNoneFalse570.00
3533858127288Nonecode31Medium point above 3 mts upto 6mts from tapping point to outlet via switchEach394.0394.02.0FalseNoneNoneFalseNoneFalse788.00
3533859127288Nonecode32Long point above 6 mts upto 10 mts from tapping point to outlet via switchEach570.0570.02.0FalseNoneNoneFalseNoneFalse1140.00
3533860127288Nonecode33Supplying and flush mounting powder coated/Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 1 - 3 ModuleEach138.0138.02.0FalseNoneNoneFalseNoneFalse276.00
3533861127288Nonecode344 - 5 ModuleEach177.0177.01.0FalseNoneNoneFalseNoneFalse177.00
3533862127288Nonecode35Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 1 to 3 moduleEach161.0161.02.0FalseNoneNoneFalseNoneFalse322.00
3533863127288Nonecode364 moduleEach175.0175.01.0FalseNoneNoneFalseNoneFalse175.00
3533864127288Nonecode37Supplying and fixing of modular switch / socket / stepped electronic fan regulator s / dimmer / telephone socket etc on existing modular switch plate 6 amps one way switchEach102.0102.08.0FalseNoneNoneFalseNoneFalse816.00
3533865127288Nonecode386 amps two way switchEach166.0166.01.0FalseNoneNoneFalseNoneFalse166.00
3533866127288Nonecode39stepped fan Regulator sEach357.0357.04.0FalseNoneNoneFalseNoneFalse1428.00
3533867127288Nonecode40Supply and fixing one metal Fan box with round hookEach117.0117.04.0FalseNoneNoneFalseNoneFalse468.00
3533868127288Nonecode41Supply and fixing of Metal Socket set of 20A,230V, 2pole & Earth Plug & Socket on a suitable MS box for incorporating SP/TP MCB without MCB ,complete with internal connections with all accessories completeEach945.0945.01.0FalseNoneNoneFalseNoneFalse945.00
3533869127288Nonecode42Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures seen with fish wires where ever necessary 20 mm diaMtr66.066.012.0FalseNoneNoneFalseNoneFalse792.00
3533870127288Nonecode4325 mm diaMtr78.078.012.0FalseNoneNoneFalseNoneFalse936.00
3533871127288Nonecode4440 mm dia 2.5mm thickMtr147.0147.015.0FalseNoneNoneFalseNoneFalse2205.00
3533872127288Nonecode45WIRING FOR Lighting/Power Circuits using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A 1.5 Sq.mmMtr26.026.012.0FalseNoneNoneFalseNoneFalse312.00
3533873127288Nonecode462,5 sq.mmMtr42.042.015.0FalseNoneNoneFalseNoneFalse630.00
3533874127288Nonecode474 sq.mmMtr63.063.015.0FalseNoneNoneFalseNoneFalse945.00
3533875127288Nonecode486sq.mmMtr92.092.08.0FalseNoneNoneFalseNoneFalse736.00
3533876127288Nonecode49Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB s single phase / 3 phase / single/ DOUBLE door with powder coated painting. Made out of 14SWG MS enclouser 6 Way TP & N LDB/PDBEach4940.04940.01.0FalseNoneNoneFalseNoneFalse4940.00
3533877127288Nonecode50Supplying and fixing miniature circuit breaker, on the existing MCB distribution board using necessary fixing materials and C type curve,indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K & complete wiring as required conforming to IEC 60898 5-32 Amps SPEach415.0415.01.0FalseNoneNoneFalseNoneFalse415.00
3533878127288Nonecode51Supplying and fixing 63A DP MCB miniature circuit breaker on the existing MCB distribution board Main / EMGPNL using necessary fixing materials and wiring complete as requiredEach1102.01102.01.0FalseNoneNoneFalseNoneFalse1102.00
3533879127288Nonecode52Supplying and fixing 32A DP MCB miniature circuit breaker on the existing MCB distribution board EMG PNL using necessary fixing materials and wiring complete as requiredEach739.0739.01.0FalseNoneNoneFalseNoneFalse739.00
3533880127288Nonecode53Supply of box type suitable for 28W T5 single/twin lamp and suspension mounted luminaire & optical reflector. Prewired with HF electronic ballast, push fit type lamp holders and main contactors. Channel cover shall be made of CRCA MS sheet & finishing is done with stove enameled white with end caps made of engineering plastic 1x 4 -28WEach1269.01269.04.0FalseNoneNoneFalseNoneFalse5076.00
3533881127288Nonecode54Supplying capacitor type 48 sweep ceiling fan complete with down rod blades , shackle canopies etc suitable for operation on 230V 50 cycles single phase AC supply conforming to ISS - 374 - 1979 and with double ball bearing system Khaitan, Crompton greaves, UshaEach2984.02984.04.0FalseNoneNoneFalseNoneFalse11936.00
3533882127288Nonecode55Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing S hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. ---- etc., complete as per specificaiton with all lead and lift and as per directions of the Engineer-in-chargeEach162.0162.04.0FalseNoneNoneFalseNoneFalse648.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17211207710000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17211207710000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17211207710001NoneNoneELIGIBILITYBidder/Contractor must attach Valid Civil PWD Class-II and above registration licence CertificateNone
17211207710000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17211207710000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17211208230000NoneNoneELIGIBILITYBidder/Contractor to qualify for award of this contract must attach Turnover Certificate certified by CA of last five years i.e.,2018-19, 2019-20 ,2020-21, 2021-22 and 2022-23 achieved in at least two financial years a minimum financial turnover of usually not less than two times the estimate cost.None
17211208280000NoneNoneELIGIBILITYBidder/Contractor to qualify for award of this contract must attach similar nature of work done certificate indicating the Indent number and bill amount, and which should be certified from the competent authority not less than rank of Executive Engineer, satisfactorily completed at least 50 percentage of the contract value, as prime contractor, i.e.,2018-19, 2019-20 ,2020-21, 2021-22 and 2022-23None
17211208760000NoneNoneELIGIBILITYBidder/Contractor must attach clear scan copy of Nationalized/Scheduled bank DD for difference amount if rates quoted below SR in the name of Municipal Commissioner CMC Rabkavi-Banahatti.None
17211208820000NoneNoneELIGIBILITYBidder/Contractor must attach all other required documents as per KW-1None
17211209100000NoneNoneELIGIBILITYBidder/Contractor must read carefully all the qualification criteria and bid documents and attach all the needful documents without fail.None
17211209160000NoneNoneELIGIBILITYThe intending contractors are requested to note that they should abide by the detailed instructions and conditions contained in the Standard Tender documents KW1None
17211273590000NoneNoneELIGIBILITYThis work is Randomized under DMA/2024-25/LOT1310 and which is classified as :Others Category workNone
17211273650000NoneNoneELIGIBILITYThe successful Tenderer shall deliver to the Employer a Security deposit in any of the forms given Clause 24.1 of ITT for an amount equivalent to 5% of the Contract price plus additional security for unbalanced tenders in accordance with Clause 25.5 & 24.3 of ITT and Clause 44 of the Conditions of Contract.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneBidder/Contractor to qualify for award of this contract must attach similar nature of work done certificate indicating the Indent number and bill amount, and which should be certified from the competent authority not less than rank of Executive Engineer, satisfactorily completed at least 50 percentage of the contract value, as prime contractor, i.e.,2018-19, 2019-20 ,2020-21, 2021-22 and 2022-23Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneBidder/Contractor must attach Valid Civil PWD Class-II and above registration licence CertificateCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneBidder/Contractor must attach all other required documents as per KW-1Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- BID Documents
NoneNoneNoneNoneBidder/Contractor to qualify for award of this contract must attach Turnover Certificate certified by CA of last five years i.e.,2018-19, 2019-20 ,2020-21, 2021-22 and 2022-23 achieved in at least two financial years a minimum financial turnover of usually not less than two times the estimate cost.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneBidder/Contractor must attach clear scan copy of Nationalized/Scheduled bank DD for difference amount if rates quoted below SR in the name of Municipal Commissioner CMC Rabkavi-Banahatti.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Below Difference DD
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Bidder/Contractor must attach Valid Civil PWD Class-II and above registration licence CertificateTrueTechnical Bid
Bidder/Contractor to qualify for award of this contract must attach Turnover Certificate certified by CA of last five years i.e.,2018-19, 2019-20 ,2020-21, 2021-22 and 2022-23 achieved in at least two financial years a minimum financial turnover of usually not less than two times the estimate cost.TrueTechnical Bid
Bidder/Contractor to qualify for award of this contract must attach similar nature of work done certificate indicating the Indent number and bill amount, and which should be certified from the competent authority not less than rank of Executive Engineer, satisfactorily completed at least 50 percentage of the contract value, as prime contractor, i.e.,2018-19, 2019-20 ,2020-21, 2021-22 and 2022-23TrueTechnical Bid
Bidder/Contractor must attach clear scan copy of Nationalized/Scheduled bank DD for difference amount if rates quoted below SR in the name of Municipal Commissioner CMC Rabkavi-Banahatti.TrueTechnical Bid
Bidder/Contractor must attach all other required documents as per KW-1TrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone