createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1719836464652
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee3260.00
emd200000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose25-07-2024 16:30:00
tenderQueryClose22-07-2024 16:30:00
technicalBidOpen26-07-2024 17:00:00
publishedDate16-07-2024 17:49:06
publishedByPostRDPR_EE_DIV_RCR
publishedByUserKPE14312 - VENKATESH GALAG
bidValidityPeriod90
noOfCalls1
preBidMeetingDate10-07-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonAnand Patil
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9972323779
tenderSupplierListNone
tenderSchedule
createdTs1719836464694
version4
createdDateNone
modifiedDateNone
tenderNumberRDPR/2024-25/BD/WORK_INDENT6038
titleConstruction of Proposed MRF Center (Material Recovery Facility) of PEB Structure in Pothnal Village of Pothnal Grama Panchayath at Manvi Taluka of Raichur District. (SWM For the Year 2023-24)
descriptionConstruction of Proposed MRF Center (Material Recovery Facility) of PEB Structure in Pothnal Village of Pothnal Grama Panchayath at Manvi Taluka of Raichur District. (SWM For the Year 2023-24)
categoryWORKS
categoryTextWorks
ecv13032683.07
deptNameRural Development and Panchayat Raj Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location963
locationNameRDPR Division Office Raichur
provisionalAmount16000000.0
groupOverheadTotal0.0
fileNumberEE/PRED/RCR/SBM/2023-24/POTHNAL/MANVI
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17198364650000NoneNoneBuildingsConstruction of Proposed MRF Center (Material Recovery Facility) of PEB Structure in Pothnal Village of Pothnal Grama Panchayath at Manvi Taluka of Raichur District.12198319.17
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3428312121491None001KSRB 2-2.2 : Earthwork excavation for foundation of buildings, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in hard soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50 m. after breaking of clods complete as per specifications.Cum254.1254.1321.5FalseNoneNoneFalseNoneFalse81693.150
3428313121491None002KSRB 4-1.2: Providing and laying in position plain cement concrete of mix CC 1:3:6 (M10) with OPC cement @ 220 kgs with 40mm and down size graded granite metal coarse aggregates @ 0.892cum and fine aggregates @ 0.465cum machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation and plinth, including cost of all materials, labour, HOM of machinery, curing complete as per specifications.Cum5947.25947.2126.05FalseNoneNoneFalseNoneFalse749644.560
3428314121491None003KSRB 4.2.2 : Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.460cum, with superplastisiser @ 3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in foundation for footings, pedastals, retaining walls, return walls, walls (any thickness) including attached plasters, columns, pillars & plinths etc including cost of all materials, labour, HOM of machinery, curing, complete as per specifications.Cum7889.77889.764.85FalseNoneNoneFalseNoneFalse511647.0450
3428315121491None004Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specificationTonne93929.8593929.853.3973FalseNoneNoneFalseNoneFalse319107.8794050
3428316121491None005KSRB 5.2-3 : Providing and constructing granite / trap / basalt size stone masonry in foundation with cement mortar 1:6, stone hammerd dressed in courses not less than 20 cms high, bond stones at two m. apart in each course including cost of materials, labour, curing complete as per specifications. KBS 5.1.13 (Item No. 5.6 Page No. 25 PWD SR)Unit5891.555891.5538.12FalseNoneNoneFalseNoneFalse224585.8860
3428317121491None006KSRB 5.3-3 : Providing and constructing granite / trap / basalt size stone masonry in basement with cement mortar 1:6, edges of stones chistle dressed in courses not less than 15 cms high, bond stones at two m. apart in each course including cost of materials, labour, curing complete as per specifications. KBS 5.1.13 (Item No. 5.9 Page no. 25 PWD SR)Cum6708.456708.4526.52FalseNoneNoneFalseNoneFalse177908.0940
3428318121491None007Providing and laying in position plain cement concrete of mix CC 1:2:4 (M15) with cement @ 240 kgs with 20mm and down size graded granite metal coarse aggregates @ 0.69cum and fine aggregates @ 0.459cum machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation and plinth, & cills including cost of all materials, labour, HOM of machinery, curing complete as per specifications.Cum5947.25947.283.53FalseNoneNoneFalseNoneFalse496769.6160
3428319121491None008Earthwork excavation ( in deposits) and filling sides of foundation upto plinth in layers not exceeding 20 cms. in depth, compacting each deposited layer by ramming after watering with lead upto 50m. and lift upto 1.5 m. including cost of all labour complete as per specifications.Cum279.3279.3650.26FalseNoneNoneFalseNoneFalse181617.6180
3428320121491None009Providing and supplying Non load bearing bricks of size 200/150/100 mm thickness for infill masonry with excellent thermal and sound insulation with density 700-800kg/m3 and compressive strength 3.5 N/mm2 & water absorption not greater than 15% & U value 1.00 W/m2K laid with Cement Mortar 1:6 conforming to Building envelope as per GRIHA certification etc complete.Sqm779.1779.1109.15FalseNoneNoneFalseNoneFalse85038.7650
3428321121491None010Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1375.51375.5320.57FalseNoneNoneFalseNoneFalse440944.0350
3428322121491None011Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm389.55389.55951.02FalseNoneNoneFalseNoneFalse370469.8410
3428323121491None012Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeKgs118.65118.6551464.83FalseNoneNoneFalseNoneFalse6106302.07950
3428324121491None013Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge.0.63 mm thick with zinc coating not less than 275 g/ m².Sqm922.95922.952031.39FalseNoneNoneFalseNoneFalse1874871.40050
3428325121491None014Providing and fixing 1mm thick M.S. sheet garage door with frame and diagonal braces of size 40x40x6 mm angle Iron, using M.S. flats 30x6 mm for diagonal braces and central cross pieces 3.15mm thick M.S. Gusset plates at the junctions and corners, with handles, stoppers and locking arrangements etc., including applying a priming coat of red lead paint cost of materials, labour, HOM of machinery complete as per specifications. 1 double leaf door of size 2.4x2.4mSqm4701.94701.938.17FalseNoneNoneFalseNoneFalse179471.5230
3428326121491None015SOLID PVC DOOR FRAME Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-chargeSqm333.9333.920.59FalseNoneNoneFalseNoneFalse6875.0010
3428327121491None016SOLID PANEL PVC DOOR SHUTTER Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm fro styles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form styles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the styles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 m.m Aluminium hinges. (Item No. 9.83 Page No. 60 PWD SR)Sqm1667.41667.420.59FalseNoneNoneFalseNoneFalse34331.7660
3428328121491None017Providing & fixing Vitrified glazed tiles of approved quality & colour of size 600x600x10mm thick fixed on a bed of 12mm thick cement mortar 1:3 mix, flush pointing with white cemnt using colour pigment, including cost of materials, labour, curing complete as per specificationSqm1392.31392.382.4FalseNoneNoneFalseNoneFalse114725.520
3428329121491None018Providing skirting, dado, rises of steps with colour glazed tiles on 10mm thick cement plaster 1:3 and jointed with white cement slurry over rough plaster surface ( excluding cost of rough plastered surface which should be measured and paid separately ) using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. Specification No.KBS 14.16, 14.17 Colour glazed tiles 30x45 cms 6mm thick with border of size 30x10Sqm1461.61461.6127.68FalseNoneNoneFalseNoneFalse186617.0880
3428330121491None019Providing and fixing white vitreous china clay, water closet Indian type ( Squatting pan ) of size 580mm with footrests, 100mm S or P trap, (approved make) cutting and making good the wall and floor wherever required, including cost of materials, labour complete as per specifications.Nos6549.96549.97.0FalseNoneNoneFalseNoneFalse45849.30
3428331121491None020KSRB 11-11.3 : Providing and fixing white vitreous china clay, flat back wash basin size 550x400mm with a pair of 15mm C.P brass pillar taps with C.I / M.S brackets, 32 mm C.P. brass waste of standard pattern, painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete as per specifications. Specification No. KBS 11 (Item No. 12.25 Page No. 83 PWD SR)No2462.252462.254.0FalseNoneNoneFalseNoneFalse9849.00
17198364650000NoneNoneBuildingsFor Water Supply and Sanitation Work57506.4
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3428332121492None001Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complet ) (WS & UGD works CSR 2021-22 Vol-V Pg.No.151 SOR. Code.O010) 0.00mtrs. to 50.00 mtrs depthRmtr364.35364.3550.0FalseNoneNoneFalseNoneFalse18217.50
3428333121492None002Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External workRmtr464.1464.150.0FalseNoneNoneFalseNoneFalse23205.00
3428334121492None003Providing and fixing brass bib cock of approved quality : 20 mm nominal boreRmtr893.55893.5518.0FalseNoneNoneFalseNoneFalse16083.90
17198364650000NoneNoneBuildingsFor Pumping Machinery at Proposed Borewell163012.5
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3428335121493None001Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 3 HP (WS & UGD works CSR 2021-22 Vol-V Pg.No.160 SOR. Code.P150E) 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00” Designed 4.00 HP Head 90 m Discharge 1.339LPSNo37747.537747.51.0FalseNoneNoneFalseNoneFalse37747.50
3428336121493None002Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments.(WS & UGD works CSR 2021-22 Vol-V Pg.No.161 SOR. Code.P230E)Rmtr304.5304.595.0FalseNoneNoneFalseNoneFalse28927.50
3428337121493None003Supply and delivery at site of brand new best make pressure gauge bourdon type as per IS 778/1984 with ISI Mark and as per its latest amendments (WS & UGD works CSR 2021-22 Vol-V Pg.No.162 SOR. Code.P240B)Nos472.5472.51.0FalseNoneNoneFalseNoneFalse472.50
3428338121493None004Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments(WS & UGD works CSR 2021-22 Vol-V Pg.No.162 SOR. Code.P250A)Nos1312.51312.51.0FalseNoneNoneFalseNoneFalse1312.50
3428339121493None005Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments (WS & UGD works CSR 2021-22 Vol-V Pg.No.162 SOR. Code.P260A)Nos1338.751338.751.0FalseNoneNoneFalseNoneFalse1338.750
3428340121493None006Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Outdoor type NOTE: 1) DOL Direct Online Starter 2) S-D- Star Delta Starter (WS & UGD works CSR 2021-22 Vol-V Pg.No.162 SOR. Code.P280A)Set13125.013125.01.0FalseNoneNoneFalseNoneFalse13125.00
3428341121493None007Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets. (WS & UGD works CSR 2021-22 Vol-V Pg.No.162 SOR. Code.P290A)Kvar577.5577.54.0FalseNoneNoneFalseNoneFalse2310.00
3428342121493None008Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box.(WS & UGD works CSR 2021-22 Vol-V Pg.No.162 SOR. Code.P300A)3 Poles1312.51312.51.0FalseNoneNoneFalseNoneFalse1312.50
3428343121493None009Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments. (WS & UGD works CSR 2021-22 Vol-V Pg.No.163 SOR. Code.P320A)Rmtr603.75603.7590.0FalseNoneNoneFalseNoneFalse54337.50
3428344121493None010Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. (WS & UGD works CSR 2021-22 Vol-V Pg.No.163 SOR. Code.P360A)Job6457.56457.51.0FalseNoneNoneFalseNoneFalse6457.50
3428345121493None011Labour charges for erection of Outdoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. (WS & UGD works CSR 2021-22 Vol-V Pg.No.163 SOR. Code.P370A)Job1417.51417.51.0FalseNoneNoneFalseNoneFalse1417.50
3428346121493None012Labour charges for providing connection using insulated sheathed steel wire cable as per IS 1554/ 1988 with latest amendments from KPTCL pole to meter board unit, with all necessary materials ,tools and equipments,as per specificationswith testing of as per instructions of engineer incharge of work. (WS & UGD works CSR 2021-22 Vol-V Pg.No.163 SOR. Code.P390B)Rmtr204.75204.7525.0FalseNoneNoneFalseNoneFalse5118.750
3428347121493None013Providing main connection from pole PVC insulated sheathed steel wire cable in new trench as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit. (WS & UGD works CSR 2021-22 Vol-V Pg.No.163 SOR. Code.P400A)Rmtr141.75141.7520.0FalseNoneNoneFalseNoneFalse2835.00
3428348121493None014Providing main connection from pole PVC insulated sheathed steel wire cable in GI pipe as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit. (WS & UGD works CSR 2021-22 Vol-V Pg.No.164 SOR. Code.P410A)Rmtr84.084.020.0FalseNoneNoneFalseNoneFalse1680.00
3428349121493None015Providing,Supplying and fixing suitable for 1.1 KV class UG cable filled with necessary bitumen/insulating compound complete with terminals, clamps,bolts,nuts and washers etc. with necessary materials and labour tools and equipments as per instructions of engineer incharge of work. (WS & UGD works CSR 2021-22 Vol-V Pg.No.164 SOR. Code.P420B)Each682.5682.51.0FalseNoneNoneFalseNoneFalse682.50
3428350121493None016Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. (WS & UGD works CSR 2021-22 Vol-V Pg.No.164 SOR. Code.P430A)Job3937.53937.51.0FalseNoneNoneFalseNoneFalse3937.50
17198364650000NoneNoneBuildingsFor Pipe Line Work199439.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3428351121494None001Earth work excavation for pipelines/cables by Manual means upto 600mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.(PWD works CSR 2021-22 Vol-I Pg.No.6 It.no 1.6.1)Cum486.94486.94172.13FalseNoneNoneFalseNoneFalse83816.98220
3428352121494None002Providing bedding for the pipeline trenches in black cotton and rock reaches including watering and consolidation by punners etc. complete with all lead and lift with MurrumCum383.25383.2519.13FalseNoneNoneFalseNoneFalse7331.57250
3428353121494None003Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete.Upto 110mm dia Coil shall be used. (Contractor will make his own arrangements for procuring water for testing) (WS & UGD works CSR 2021-22 Vol-V Pg.No.121 SOR. Code.K010 )Rmtr177.28177.28425.0FalseNoneNoneFalseNoneFalse75344.00
3428354121494None004SHDPE electro fusion specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bends, reducers. Material Rates (WS & UGD works CSR 2021-22 Vol-V Pg.No.3 MAT.Code) 63 mm dia Electro fusion ElbowNo211.0211.02.0FalseNoneNoneFalseNoneFalse422.00
3428355121494None005SHDPE electro fusion specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bends, reducers. Material Rates (WS & UGD works CSR 2021-22 Vol-V Pg.No.3 MAT.Code) 63 mm dia Electro fusionTeeNo210.0210.02.0FalseNoneNoneFalseNoneFalse420.00
3428356121494None006Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For Heavy Duty GI pipe (WS & UGD works CSR 2021-22 Vol-V Pg.No.142 SOR. Code.N020 )Rmtr1005.461005.4610.0FalseNoneNoneFalseNoneFalse10054.60
3428357121494None007Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications. (PWD works CSR 2021-22 Vol-I Pg.No.7 It.no 1.10)Cum128.1128.1172.13FalseNoneNoneFalseNoneFalse22049.8530
17198364650000NoneNoneBuildingsFOR ELECTRICAL WORK414406.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3428358121495None001Supplying Heavy Guage PVC Conduit pipe 19/20 Dia 2mm thick confirming to IS 2509 with suitable size bends metal /PVC junction boxes ,adhesive paste etc., and running before concreting the slab.The conduite should be tied to the before reinforcement rods by using binding wires & unused ways of junction boxes and pipe ends should be covered using PVC end enclousees,run with 18SWG GI fishes wire wherever necessaryMtr45.1545.152500.0FalseNoneNoneFalseNoneFalse112875.00
3428359121495None002Supplying & Fixing Sheet Meatal Box made out of 18SWG sheet metal with Necssaery Holes for Cable/Conductor entry ass Reqiured with one coat of Priemer approved make etc., 180x90x65mmNos115.5115.550.0FalseNoneNoneFalseNoneFalse5775.00
3428360121495None003Wiring for lighting/Power circute using one of FRLS PVC insulated 1100V Grade Multi Starded copper with low conducter Resistence single core wire is open or concealed system of wiring with Specified IS -694:1990 and Confirming to GTP of Group A 4 sqmmRmtr44.2144.212600.0FalseNoneNoneFalseNoneFalse114946.00
3428361121495None004Supplying & adopting Loop System of in Existing PVC Conductor/Casing ,Caping Using 1100 V Grade copper conductor Flexible multi strand FRLS PVC insulated 2x1 Sqmm able with low conducter Resistence single core wire is open or concealed system of wiring Confirming to GTP without swich the ohter end of wire shall be terminted with sufficent Loose length in a wood /PVC Round Block complete for Each outlet Group A Medium Point Above 3.00mtr upto 6.00 mtr from Tapping Point to Outlet Wire Swich BoxNos225.75225.75100.0FalseNoneNoneFalseNoneFalse22575.00
3428362121495None005Supplying & Mounting 2.0 Nos Two way 6Amps Flush Type Switches either surface/flush Mounted on Existing Gang Box are in 4mm thich plsatic sheet & mouted on a flush mounted wooden box & wiringNos179.55179.5550.0FalseNoneNoneFalseNoneFalse8977.50
3428363121495None006Supplying & Fixing Bakelight DP /Socket/ Switch with/without Neon indicator Over Existing wood Board or Flush Mounting in Plastic Plates /Nithces as per IS-1293 & IS-3854 Group A 32 Amps Flush /Projected type DP SwitchesNos196.35196.3550.0FalseNoneNoneFalseNoneFalse9817.50
3428364121495None007Supplying & Fixing Superior Quality modular switch mounting poly corbonate plate with Necessary supporying Backplate with Required Nos of Machine Screws Bolts ,Nuts Etc., Complete on the Existing Metal /PVC Box 4 moduleNos128.1128.1150.0FalseNoneNoneFalseNoneFalse19215.00
3428365121495None008Supplying of Horizental Type Street Light Florcent Fitting Suitable for Single /winlamp of 24 watts /25watts FTL T5 lamp Housing shall be with Pressure Dye cast Alluminum with UV Protected Clear acrylic corbonate lamp holder low loss high frequency Electronic Ballast with IP 54 Protection -do-2x4'-28wattsNos1959.31959.330.0FalseNoneNoneFalseNoneFalse58779.00
3428366121495None009Supplying& Fixing miniture circute breaker Existing MCB distribution Board using necessary fixing Material & C Type curve Indictor ON/OFF Energy cross-3 with short circute breaking capacity of 10K & complete wiring as required confirming IEC 60898 40-63Amps TPNNos2032.82032.820.0FalseNoneNoneFalseNoneFalse40656.00
3428367121495None010Supplying & Fixing Ceiling FanEach2079.02079.010.0FalseNoneNoneFalseNoneFalse20790.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17198364660000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17198364660000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17198364660000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17198364660000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17198364660000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17198373610000NoneNoneELIGIBILITYQualifications of the tenderer required as mentioned in the Technical Bid KW-4 in General conditions 3 must be furnished.None
17198377490000NoneNoneELIGIBILITYTender of the contractor, who have not completed the work in time, not executed the agreement in time in any other cases in this Division as per Clause 3.4 of Standard Tender Document and practices as mentioned in clause 25 of the standard tender document will not be accepted.None
17198377610000NoneNoneELIGIBILITYThe undersigned reserves the right to accept any or all tenders without assigning any reason.None
17198377730000NoneNoneELIGIBILITYContractor should execute the work by procuring cement, steel any other materials/Machinery for the work on their own and necessary quality test certificate should be produced and approval of the same.None
17198388650000NoneNoneELIGIBILITYOther details can be seen in the tender documentsNone
17198388740000NoneNoneELIGIBILITYContractors should have to upload the Scan copy of all necessary Qualification Documents/ Certificates, and submitted duly attested by notary while tender Evaluvation in this DivisionNone
17198388800000NoneNoneELIGIBILITYThe Department is not responsible for any delay in accessing e-procurement portal.None
17198388860000NoneNoneELIGIBILITYTenderer shall note that the Tenders of those found Eligible as mentioned in Clause 3 Qualification of Instructions to Tenders (ITT), will only be considered for evaluation.None
17198388920000NoneNoneELIGIBILITYContractors should have to upload the necessary Qualification details as Section 3 Clause 1.1 to 1.10 in prescribed formats of KW-4.None
17198388970000NoneNoneELIGIBILITYThe contractor should counter check all the designs of the scheme before execution / procurement of material and bring to the notice of the departmental officers for rectification.None
17198389010000NoneNoneELIGIBILITYThe contractors have to verify the designs and drawings prepared by the department and supplied for construction. correct the same for any mistakes and to submit it for the approval of the department prior to commencement of execution.None
17198389070000NoneNoneELIGIBILITYThe contractor should furnish the Contractor license CertificateNone
17198389140000NoneNoneELIGIBILITYSuccessful bidder submitting bids below the amount put to tender will be regularized to submit the difference amount in the form of FDR/TDR/DD/Pledge on the name of EE PRED Raichur within 20 days from the date of receiving the letter of acceptance. Failing which EMD will be forfeited and further action will be taken as per G O No FD PCL 2008 Bangalore Dated 14/10/2008. Cluase 25 of KW-4.None
17198389210000NoneNoneELIGIBILITYThe Building constructed under this programme shall be of high standard, requiring no major repairs for 3 years, The contractor shall furnish performance guarantee for 3 years as per clause and the performance guarantee will be released only after 3 years after completion of work.None
17198389260000NoneNoneELIGIBILITYThe Tenderer shall obtain the workdone certificate in the prescribed form from the competent authority not below the rank of Executive Engineer (District Level Officer) and scan the Original Certificate and attach the scanned file to the Bid. The Original Certificate / Certificates shall be produced whenever required.None
17198389300000NoneNoneELIGIBILITYThird party inspection is mandatory for all the works in this programmeNone
17198389340000NoneNoneELIGIBILITYThe work should be completed within the stipulated period from the date of agreement & The date of agreement itself is the date of commencement of the workNone
17198389410000NoneNoneELIGIBILITYThe work should be completed in 11 months (including mansoon)None
17198389810000NoneNoneELIGIBILITYThe defect liability period is 2 years and 3 years for major construction repairs.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. 260.65 Lakhs)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneSatisfactorily completed as prime contractor at-least one such similar work of value not less than Rs. 65.16 LakhsPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneExecuted in any one year, the following minimum quantities of work: (1) Earthwork excavation & Construction of Embankment: 915.00 Cum (2) PCC/RCC : 219.54 Cum (3) Steel : 2.72 Ton, (4) SSM/BBM/Solid concrete blocks: 395.00 Cum (5) Plastering : 760.82 SqmPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneTenderer or his identifiedPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. 35.54 LakhsCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
PWD Contractor Registration CertificateTrueTechnical Bid
Previous Five years Financial Turn over 2019-20 to 2023-24TrueTechnical Bid
Similar nature Work done CertificateTrueTechnical Bid
Quantity wise Work done certificateTrueTechnical Bid
Line of credit Bank letter headTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1720262527000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of the Executive Engineer, P.R.E.Divisioin, Beside District Court Complex, Arab Mohalla, RAICHUR
streetNone
cityRaichur
stateKarnataka
pin584101
tenderRecallDTONone