createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1721111370735
version6
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd600000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose23-07-2024 17:30:00
tenderQueryClose19-07-2024 17:00:00
technicalBidOpen25-07-2024 11:00:00
publishedDate16-07-2024 17:16:12
publishedByPostKKRTC_EE_HOFF_KLB
publishedByUserKPE11172 - CHANNAN BORAIAH
bidValidityPeriod90
noOfCalls1
preBidMeetingDate22-07-2024 17:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonChannana Boraiah
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08472220663
mobileNumber7760992033
tenderSupplierListNone
tenderSchedule
createdTs1721111370774
version10
createdDateNone
modifiedDateNone
tenderNumberKKRTC/2024-25/BD/WORK_INDENT46
titleConstruction of New Ultra Modern Bus Station at Hulsur Dist Bidar
descriptionConstruction of New Ultra Modern Bus Station at Hulsur Dist Bidar
categoryWORKS
categoryTextWorks
ecv40000000.00
deptNameKalyana Karnataka Road Transport Corporation
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location5935
locationNameKalyana Karnataka Road Transport Corporation Head Office Kalburgi
provisionalAmount40000000.0
groupOverheadTotal987764.62
fileNumberKKT/EEG/KLB/DB/T/259/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17211113710000NoneNoneBuildingsConstruction of New Ultra Modern Bus Station at Hulsur Dist Bidar39012235.38
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3530312127060Nonecode01SRP. Vol.II (163/19.3) Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer.in.chargeCum3005.813005.8153.78FalseNoneNoneFalseNoneFalse161652.46180
3530313127060Nonecode02SRP. Vol.II (163/19.12.1)Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking to the appropriate disposal area as per direction of Engineer. in.charge.Cum297.36297.360.66FalseNoneNoneFalseNoneFalse196.25760
3530314127060Nonecode03SRP. Vol.II (163/19.13.2)Taking out doors, windows and clerestory window shutters (steel or wood) including stacking to the appropriate disposal area as per direction of Engineer.in.chargeSqm152.4152.44.2FalseNoneNoneFalseNoneFalse640.080
3530315127060Nonecode04SRP. Vol II (163/19.10.2) Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually/ by mechanical means including stacking of serviceable and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer.in.charge. in cement morterCum1240.241240.24126.68FalseNoneNoneFalseNoneFalse157113.60320
3530316127060Nonecode05Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as perdrawing and technical specifications, including setting out, shoring, strutting, barricading,caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.SRP. Vol.I (8/1.14.1) Depth exceeding 1.5 m, but not exceeding 3 m.In all kinds of soils Depth upto 3 mCum126.38126.381295.39FalseNoneNoneFalseNoneFalse163711.38820
3530317127060Nonecode06Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.SRP. Vol.I (8/1.15.1) 1 In ordinary/soft rock without blasting upto 1.5 m depthCum449.76449.76180.49FalseNoneNoneFalseNoneFalse81177.18240
3530318127060Nonecode07Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. SRP. Vol.I (7/1.8)Cum587.29587.291125.0FalseNoneNoneFalseNoneFalse660701.250
3530319127060Nonecode08Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub.base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. SRP. Vol.III (24/4.27)Cum3170.63170.6150.0FalseNoneNoneFalseNoneFalse475590.00
3530320127060Nonecode09Construction of dry lean cement concrete Sub. base over a prepared sub.grade with coarse and fine aggregate conforming to IS. 383, the size of coarse aggregate not exceeding 25 mm,aggregate cement ratio not to exceed 15.1, aggregate gradation after blending to be as per table 600.1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8.10 t vibratory roller, finishing and curing.SRP. Vol.III (43/6.1)complete in C.C. 1.6.12 prop )Cum6095.886095.88150.0FalseNoneNoneFalseNoneFalse914382.00
3530321127060Nonecode10Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing,and all the other appurtenances requiredcomplete the work as pertechnical specifications. (The cost of steel reinforcement & formwork shall be paid separately).SRP. Vol.I (15/2.1.2) Mix 1.4.8( M7.5) Using 40 mm nominal size graded crushed coarse aggregatesCum7017.77017.7189.1FalseNoneNoneFalseNoneFalse1327047.070
3530322127060Nonecode11Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.SRP. Vol.I (7/1.9)Cum329.57329.57522.27FalseNoneNoneFalseNoneFalse172124.52390
3530323127060Nonecode12KSRB 2.3 . Filling (new earth )Refilling available earth around trenches/pipelines, cables in layersnot exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m .Including cost of all labour complete as per specifications.SRP. Vol.I (7/1.11)Cum520.38520.38980.18FalseNoneNoneFalseNoneFalse510066.06840
3530324127060Nonecode13Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators,providing weep holes wherever necesary, including all lead & lifts, costof all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).SRP. Vol.I (17/2.4.1) Mix 1.2.4 (M15) Using 20 mm nominal size graded crushed coarse aggregatesCum7934.567934.5616.5FalseNoneNoneFalseNoneFalse130920.240
3530325127060Nonecode14Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).SRP. Vol.I (15/2.2.3) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SRP 115/1 (Foundation upto plinth (a) Isolated)Cum8478.338478.33121.36FalseNoneNoneFalseNoneFalse1028930.12880
3530326127060Nonecode15Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).SRP. Vol.I (15/2.2.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SRP 115/1 (Foundation upto plinth (a) Isolated)Cum8412.768412.7665.42FalseNoneNoneFalseNoneFalse550362.75920
3530327127060Nonecode16Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP. Vol.I (17/2.5.2) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SRP 115/8 (Column & Piers as per corrigendum.3)Cum14413.4214413.4239.79FalseNoneNoneFalseNoneFalse573509.98180
3530328127060Nonecode17Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP. Vol.I (17/2.5.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SRP 115/8 (Column & Piers as per 3rd Corrigendum.3)Cum13964.7713964.7733.07FalseNoneNoneFalseNoneFalse461814.94390
3530329127060Nonecode18Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP. Vol.I (17/2.5.2) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SRP 115/8 (Plinth beams of Building as per corrigendum.3)Cum12717.7212717.7238.36FalseNoneNoneFalseNoneFalse487851.73920
3530330127060Nonecode19Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP. Vol.I (17/2.5.2) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SRP 115/12 (Beam and Lintel of Building as per corrigendum.3)Cum13565.5613565.5682.73FalseNoneNoneFalseNoneFalse1122278.77880
3530331127060Nonecode20Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP. Vol.I (17/2.5.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum13143.3113143.3114.05FalseNoneNoneFalseNoneFalse184663.50550
3530332127060Nonecode21Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP. Vol.I (17/2.5.2) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SRP 116/13 (Roof (Straight & Arched as per corrigendum 3)Cum12717.7212717.72240.3FalseNoneNoneFalseNoneFalse3056068.1160
3530333127060Nonecode22Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP. Vol.I (17/2.5.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SRP 116/13 (Roof (Straight & Arched as per 3rd Corrigendum)Cum12321.8612321.8665.21FalseNoneNoneFalseNoneFalse803508.49060
3530334127060Nonecode23Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP. Vol.I (17/2.5.2) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SRP 116/20 (Chejjas,canopy & other Arch Projection of minor section)Cum12293.7912293.790.49FalseNoneNoneFalseNoneFalse6023.95710
3530335127060Nonecode24Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP. Vol.I (17/2.5.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum9036.039036.0362.03FalseNoneNoneFalseNoneFalse560504.94090
3530336127060Nonecode25Construction of M40 grade un.reinforced,Cement Concrete Pavement with OPC/PPC/PSC dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383.2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing SRP. Vol.III (43/6.2)Cum11226.5811226.58300.0FalseNoneNoneFalseNoneFalse3367974.00
3530337127060Nonecode26Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot ressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part.I) 1991.from manufacturer complete as per spcification.SRP. Vol.II (106/12.57.4) 35 mm thick Both side teakSqm5615.155615.1516.38FalseNoneNoneFalseNoneFalse91976.1570
3530338127060Nonecode27Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.SRP. Vol.II (100/12.12)Cum153886.28153886.280.42FalseNoneNoneFalseNoneFalse64632.23760
3530339127060Nonecode28Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer.in.charge. SRP. Vol.II (105/12.54)Rmtr394.0394.017.1FalseNoneNoneFalseNoneFalse6737.40
3530340127060Nonecode29VOL II SRP 106/12.55.1 Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer.in.charge fixed to frames with 3 nos of 75mm Aluminium hinges (both side prelam)Sqm2931.472931.474.73FalseNoneNoneFalseNoneFalse13865.85310
3530341127060Nonecode30Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.SRP. Vol.II (85/11.34A)Kg208.15208.15978.83FalseNoneNoneFalseNoneFalse203743.46450
3530342127060Nonecode31Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1.6 (1 cement . 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.SRP. Vol.II (14/6.8)Cum9873.599873.59124.59FalseNoneNoneFalseNoneFalse1230150.57810
3530343127060Nonecode32Providing 15 mm cement plaster on the rough side of single or half brick wall of mix .1.4 (1 cement. 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer.in.charge. SRP. Vol.II (41/8.2.1)Sqm365.51365.511165.55FalseNoneNoneFalseNoneFalse426020.18050
3530344127060Nonecode33Providing 12 mm cement plaster with cement mortar 1.4 (1 cement.4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer.in.charge. SRP. Vol.II (41/8.1.1)Sqm315.95315.95730.6FalseNoneNoneFalseNoneFalse230833.070
3530345127060Nonecode34Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS. 733 and IS.1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer.in.charge. (Glazing, paneling and dash fasteners to be paid for separately) .For Fixed Portion. Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications.SRP.Vol.II (11.35.1.2/86)Kg605.87605.8783.25FalseNoneNoneFalseNoneFalse50438.67750
3530346127060Nonecode35Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer.in.charge . (Cost of aluminium snap beading shall be paid in basic item).With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications.SRP.Vol.II (11.37.2/82)Sqm1450.871450.8714.58FalseNoneNoneFalseNoneFalse21153.68460
3530347127060Nonecode36Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing,polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners,stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer.in. charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer.in.Charge.SRP. Vol.II (83/11.28)Kg700.04700.04124.74FalseNoneNoneFalseNoneFalse87322.98960
3530348127060Nonecode37Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1.6, 20 mm thick, and joints finished with cement mortar 1.3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. SRP. Vol.II (64/9.30)Sqm6601.396601.39375.9FalseNoneNoneFalseNoneFalse2481462.5010
3530349127060Nonecode38Providing and laying Polished Glazed Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08Percentage and conforming to IS.15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming (Payment for grouting of joints to be made separately). SRP. Vol.II (62/9.22.2)Size of Tile 600x600 mmSqm1642.911642.91148.38FalseNoneNoneFalseNoneFalse243774.98580
3530350127060Nonecode39Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1.6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab,including cost of materials,labour,curing, polishing complete as per specifications.SRP. Vol.II (64/9.34)Sqm1914.261914.2674.2FalseNoneNoneFalseNoneFalse142038.0920
3530351127060Nonecode40Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc.complete as per design approved by Engineer.in.charge. SRP. Vol.II (69/10.2)Rmtr406.39406.3967.88FalseNoneNoneFalseNoneFalse27585.75320
3530352127060Nonecode41Providing Thermo.Mechanically Treated bars of grade Fe.500D or more Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) SRP. Vol.I (18/2.11/a)Kg110.83110.8358674.33FalseNoneNoneFalseNoneFalse6502875.99390
3530353127060Nonecode42Supplying, fitting and placing un.coated Mild steel reinforcement complete in foundation as per drawing and technical specification. SRP. Vol.I (18/2.12)Kg91.3391.3311250.0FalseNoneNoneFalseNoneFalse1027462.50
3530354127060Nonecode43Providing and fixing Structural Steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer.in.Charge.SRP. Vol.II (75/11.1)Kg131.33131.334866.75FalseNoneNoneFalseNoneFalse639150.27750
3530355127060Nonecode44Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer.in.charge) 0.50 mm (+ 0.05 Percentage) total coated thickness with zinc coating 120 grams per m2 as per IS. 277, in 240 mpa steel grade, 5.7 microns epoxy primer on both side of the sheet and polyester top coat 15.18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer.in.charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces,excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. SRP. Vol.II (26/7.38)Sqm703.75703.75286.22FalseNoneNoneFalseNoneFalse201427.3250
3530356127060Nonecode45Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non.halogenated FR grade mineral based polymer ( 2hrs fire resistance as per ASTM E119.12 and clause B, S1, do as per ENT 13501.1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories,sealing shall be done with necessary rods etc., complete SRP. Vol.II (71/10.15.1)Sqm4942.374942.3725.46FalseNoneNoneFalseNoneFalse125832.74020
3530357127060Nonecode46Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part.III). The Suspended System held with Spider Fittings of SS.316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS. 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ eams by means of SS. 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi.metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval fromstructural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts,washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glasspanel inside the SS channel shall be measured.SRP. Vol.II (160/18.7)Sqm9852.539852.5310.91FalseNoneNoneFalseNoneFalse107491.10230
3530358127060Nonecode47KSRB 7.15 .Providing , fabricating, assembling and fixing in position anodized aluminum partions using aluminium section of mat finish or glassy finish in combination of plain grove, single groove, single grove and double grove as per requirements for the frames of overall size 63.5mmx38.1mm. with thickness of 2 mm having section weight, plain sections. 1.054 kg/m, single grove thickness 1.95mm section weight. 1.094kg/m and bottom member 114.3mm x 44.45mm thickness 3.18mm weight 2.646 kg/m aluminium louvers section of size 36.5mmx34.93mm 1.45mm thick section weight 0.429kg/m bottom prortion provided with 12mm thick prelaminated sheet both sides of approved portion viz., 0.9m to 2.13m and top panel with louvers sections; the glass and panels fitted wtih glazing clips of 19mm x 17.3mm of thickness 0.9mm weight 0.13 and top panel with louvers sections; the glass and panels fitted with glazing clips of 19mmx 17.3mm of thickness 0.9mm weight 0.124kg/m aluminium setions anodised 12 to 15 microns, sections treated for removal of any rust and prevention of further rust formation, coated with greasy materials for non adherence of mortars or any other sticky materials ; vertical members embedded in the flooring by making suitable sized holes and fixing with cement mortar, with necesary opening for fixing of door of standard size ( excluding cost of door ) all the frame throughly cleaned, free from rust , scale of dirt including cost of materials, fixtures, labour and HOM of machinery complete as per specification SRP 38/7.15.2 ( Powder Coated )Sqm4049.764049.766.48FalseNoneNoneFalseNoneFalse26242.44480
3530359127060Nonecode48Constructing brick maconary inspection chamber of internal dimention 600 X 450 mm, and depth of 600mm ( Inner dimension ) with modular bricks of class designation 75 in Cm 1.6 bed concrete 150mm thick with 1.3.6 with plastering 12 mm thick with CM 1.4.CC 1.2.4 cooping 75mm thick for fixing CI cover & frame etc.(excluding cost of CI frame & cover). SRP. Vol.V 16.9/191Each5936.055936.053.0FalseNoneNoneFalseNoneFalse17808.150
3530360127060Nonecode49Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984.2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will makehis own arrangements for procuring water for testing) etc.Note. Upto 110mm dia Coil shall be used. SRP. Vol.V 94/9.1.4Rmtr581.09581.09290.0FalseNoneNoneFalseNoneFalse168516.10
3530361127060Nonecode50Supplying PVC ringtite pipes conforming to IS 4985.2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes andspecials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for. PVC pipes 110mm dia., 6 kg/sqcm & class 3 SRP. Vol.V 113/10.1.7)Rmtr509.23509.23100.0FalseNoneNoneFalseNoneFalse50923.00
3530362127060Nonecode51Supplying, lowering, laying, jointing, testing and commissioning of Glazed Stone Ware Pipes of following dia, conforming to IS 651.1992,IS 4127 with latest amendments, including conveying to work site,caulking with hemp dipped in tar and jointing with CM 1.1.5 using OPC, perfect linking and curing for 10 days and testing with water etc. with all lead, lifts and as per Technical Specifications. The cost to include the cost of all jointing materials, necessary survey works for laying of sewer lines etc. complete. The contractor will make own arrangements for procuring water for testing.150 mm dia. pipes SRP. Vol.V 187/16.1.2Rmtr719.86719.8670.0FalseNoneNoneFalseNoneFalse50390.20
3530363127060Nonecode52Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.SRP. Vol.II (50/8.51)Sqm123.89123.891061.87FalseNoneNoneFalseNoneFalse131555.07430
3530364127060Nonecode53Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade .New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer.in.charge. SRP. Vol.II (45/8.25)Sqm169.74169.741061.87FalseNoneNoneFalseNoneFalse180241.81380
3530365127060Nonecode54Finishing walls with water proofing cement paint of required shade .New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer.in.charge.. (Apex Paint) SRP. Vol.II (45/8.28)Sqm110.27110.271449.83FalseNoneNoneFalseNoneFalse159872.75410
3530366127060Nonecode55Providing and placing on terrace ( at all floor levels ) polyethylene water storage tanks,IS . 12701 marked,with cover and suitable locking arrangement and making necessary holes for for inlet,oulet and overflow pipes but without fittings and the base support for tank. SRP. Vol.II (12/13.34)Ltr11.1511.152000.0FalseNoneNoneFalseNoneFalse22300.00
3530367127060Nonecode56Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes having thermal stability for hot and cold water supply incl all CPVC plain & brass threaded fittings. This incl jointing of pipes and fittings with one step CPVC solvent cement,trenching,refilling and testing of joints complete 50mm dia as pe direction of Engineer in charge External work SRP. Vol.II (11/13.33.6) 40 mmRmtr591.0591.0100.0FalseNoneNoneFalseNoneFalse59100.00
3530368127060Nonecode5725 mmRmtr366.74366.7490.0FalseNoneNoneFalseNoneFalse33006.60
3530369127060Nonecode5820 mmRmtr268.86268.8680.0FalseNoneNoneFalseNoneFalse21508.80
3530370127060Nonecode5915 mmRmtr205.67205.6775.0FalseNoneNoneFalseNoneFalse15425.250
3530371127060Nonecode60White Vitreous China Flat back wash basin size 450x 300 mm with single 15mm C.P. brass pillar tap SRP. Vol.II (133/14.7.7)No2600.662600.662.0FalseNoneNoneFalseNoneFalse5201.320
3530372127060Nonecode61White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. SRP. Vol.II (126/14.13.2)No2888.112888.112.0FalseNoneNoneFalseNoneFalse5776.220
3530373127060Nonecode62Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete,including painting of fittings and brackets, cutting and making good the walls and floors wherever required. W.C. pan with ISI marked black solid plastic seat and lid. SRP. Vol.II (123/14.3.2)No7192.47192.42.0FalseNoneNoneFalseNoneFalse14384.80
3530374127060Nonecode63Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS . 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required .VOL II 124/14.5.1No10707.4410707.443.0FalseNoneNoneFalseNoneFalse32122.320
3530375127060Nonecode64Providing and fixing white vitreous china water closet squatting pan (Indian type) Long pattern W.C. pan of size 580 mm SRP. Vol.II (126/14.13.1)No1769.291769.293.0FalseNoneNoneFalseNoneFalse5307.870
3530376127060Nonecode65Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing SRP Vol.II (128/14.32.3)No1320.771320.772.0FalseNoneNoneFalseNoneFalse2641.540
3530377127060Nonecode66Providing and fixing C I Nahani trap of approved make confirming to ISI specifications and construction of cistern in CC 1.2.4 as per directions (Inclusive of cost of materials and fixtures) 12.5 cms x 7.5 cms SRP 90 / 12.113.2No336.3336.35.0FalseNoneNoneFalseNoneFalse1681.50
3530378127060Nonecode67Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete. 15 mm nominal bore SRP. Vol.II (117/13.5.1)No366.74366.748.0FalseNoneNoneFalseNoneFalse2933.920
3530379127060Nonecode68Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 40 mm nominal bore SRP. Vol.II (117/13.4.3)No869.78869.782.0FalseNoneNoneFalseNoneFalse1739.560
3530380127060Nonecode69Providing and fixing brass stop cock of approved quality 15 mm nominal bore SRP. Vol.II (115/13.3.1)No370.46370.4610.0FalseNoneNoneFalseNoneFalse3704.60
3530381127060Nonecode70Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation com plete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS. 4454 . part 1 and M.S. top cover of required thickness for rolling shutters. 80x0.90 mm M.S. laths with 0.90 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer.in.Charge.SRP. Vol.II (76/11.6.3)Sqm2818.732818.73101.84FalseNoneNoneFalseNoneFalse287059.46320
3530382127060Nonecode71Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS . 15622, of approved make, in all colours, shades, except White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1.4 (1 Cement . 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. SRP. Vol.II (60/9.11)Sqm1101.471101.479.56FalseNoneNoneFalseNoneFalse10530.05320
3530383127060Nonecode72Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1.3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. SRP. Vol.II (65/9.38)Sqm1724.691724.6920.25FalseNoneNoneFalseNoneFalse34924.97250
3530384127060Nonecode73Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1.3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, griding the edge to half/full round wherever required, labour, curing complete as per specification.SRP. Vol.II (65/9.40)Sqm1154.751154.7579.88FalseNoneNoneFalseNoneFalse92241.430
3530385127060Nonecode74Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M .30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer.in.charge.SRP. Vol.II (63/9.25)Sqm991.2991.2162.12FalseNoneNoneFalseNoneFalse160693.3440
3530386127060Nonecode75Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1.3 (1 cement . 3 coarse sand) proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete.SRP. Vol.II (72/10.18)Sqm4161.84161.832.0FalseNoneNoneFalseNoneFalse133177.60
3530387127060Nonecode76Supplying and fixing MS Chairs & 3 seater of approved qulaity including fixing in flooring drilling to the suitable holes grouting complete as per direction of Engineer in charge of work complete as per specifications with all lead and lift. (Approved rate)No6490.06490.030.0FalseNoneNoneFalseNoneFalse194700.00
3530388127060Nonecode77Hydraulic Excavator of 0.9 m3 bucket (J.C.B excavator) Levelling the ground SRP. Vol.I (A.45/50)Hour1672.651672.658.0FalseNoneNoneFalseNoneFalse13381.20
3530389127060Nonecode78KSRB 5.4.3 . Providing and constructing granite / trap / basalt size stone masonry in superstructure with cement mortar 1.6 edges of stones chistle dressed in courses not less than 15 cms high, bond stones at two m. apart in each course including cost of materials, labours, curing complete as per specifications. SRP. Vol.II (9/5.4) (AVAILABLE STONE)Cum6181.376181.37132.63FalseNoneNoneFalseNoneFalse819835.10310
3530390127060Nonecode79KSRB 5.4.3 . Providing and constructing granite / trap / basalt size stone masonry in superstructure with cement mortar 1.6 edges of stones chistle dressed in courses not less than 15 cms high, bond stones at two m. apart in each course including cost of materials, labours, curing complete as per specifications. SRP. Vol.II (9/5.4)Cum7915.977915.9729.2FalseNoneNoneFalseNoneFalse231146.3240
3530391127060Nonecode80Providing Flush/ Ruled pointing. Pointing on stone work with cement mortar 1.3 (1 cement . 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labur, curing as B61er specifications and as per directions of Engineer.in.charge. SRP. Vol.II (44/8.19.1)Sqm315.95315.95719.23FalseNoneNoneFalseNoneFalse227240.71850
3530392127060Nonecode81Stone Work ( Machine cut edges ) for wall lining etc,( Veneer work) upto 10 mtr height backing filled with a grout of average 12mm thick cement motar 1.3 ( 1 cement . 3 coarse sand) including pointing in white cement mortar 1.2 ( 1 white cement . 2 stone dust) with an admixture of pigment matching the stone shade ( to be secured to the backing and the sides by means of cramps and pins which shall be paid for seperately) white sand stone exposed face fine dressed with rough 30mm thick ( SRP 121/7.23.3.5 )(CSR) ( approved in Developmental works in Sedam Bus Station )Sqm3495.223495.2235.0FalseNoneNoneFalseNoneFalse122332.70
3530393127060Nonecode82Providing and laying a burried expansion joint, expansion gap being 20 mm, covered with 12 mm thick, 200 mm wide galvanised weldable structural steel plate as per IS. 2062, placed symmetrical to centre line of the JOint, resting freely over the top surface of the deck concrete, welding of 8 mm dia. 100 mm long galvanised nails spaced 300 mm c/c along the centre line of the plate, including cost of materials, labour, HOM complete as per specifications, all as specified in clause 2600.4 MORTH Specification No. 2604 SRP 31.1( 18.19 SR)Rmtr1479.371479.37100.0FalseNoneNoneFalseNoneFalse147937.00
3530394127060Nonecode83Providing 12 mm cement plaster finished with a floating coat of neat cement of mix .1.4 (1 cement. 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer.in.charge..SRP. Vol.II(41/8.4.2))Sqm386.57386.57150.0FalseNoneNoneFalseNoneFalse57985.50
3530395127060Nonecode84Korean truff (Bijapur BS Approved Rate)Sqm206.5206.550.0FalseNoneNoneFalseNoneFalse10325.00
3530396127060Nonecode85Providing & supplying of plants from forest department of plants size 14feet x 20feet with supporting guard stick including transportation loading unloading placeing the plants in pits of 1 Mtr x 1 Mtr x 1 Mtr of size pits and refiling of required quantity and watering etc., complete.Each118.0118.050.0FalseNoneNoneFalseNoneFalse5900.00
3530397127060Nonecode86Providing patti allround compound wall etc, with CM 1.3 and finished as per design and specification including scafolding etc, complete. Patti 10cm wide and 10 mm thick.Rmtr14.0214.02599.36FalseNoneNoneFalseNoneFalse8403.02720
3530398127060Nonecode87Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth,including over burden upto 20M, fixing ofcasing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes,collars and caps etc.) for SRP. Vol.V 139/12.2 Borewell depth of 0 to 50 mRmtr382.85382.8560.0FalseNoneNoneFalseNoneFalse22971.00
3530399127060Nonecode88Borewell depth of 50 to 100 mRmtr479.49479.4930.0FalseNoneNoneFalseNoneFalse14384.70
3530400127060Nonecode89Borewell depth of 100 to 150 mRmtr510.47510.4760.0FalseNoneNoneFalseNoneFalse30628.20
3530401127060Nonecode90Supplying PVC ringtite pipes conforming to IS 4985.2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes andspecials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for. PVC pipes 160mm dia., 6 kg/sqcm & class 3 SRP. Vol.V 134/1.9)Rmtr742.16742.1620.0FalseNoneNoneFalseNoneFalse14843.20
3530402127060Nonecode91Supplying PVC ringtite pipes conforming to IS 4985.2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes andspecials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for. PVC pipes 140mm dia., 6 kg/sqcm & class 3 SRP. Vol.V 113/10.1.8)Rmtr723.58723.5840.0FalseNoneNoneFalseNoneFalse28943.20
3530403127060Nonecode92Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE. 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M . 15Percentage, b) Above 30 M . 30Percentage (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/. is to be deducted for Dry Borewell towards yield test. 5 O050A Cleaning of borewells including yield.VOL.V 139/12.2Each6239.846239.841.0FalseNoneNoneFalseNoneFalse6239.840
3530404127060NoneElecl code93SRP.1.2 Concealed Conduit SystemSupplying heavy gauge PVC conduit pipe 25 mm dia 2 .mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary25mm dia 2mm thick 1.2.2Mtr96.6496.64600.0FalseNoneNoneFalseNoneFalse57984.00
3530405127060NoneElecl code94SRP. 1.3.2 -Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thickMtr97.8897.88360.0FalseNoneNoneFalseNoneFalse35236.80
3530406127060NoneElecl code951.1.2 Open Conduit System.Supplying heavy gauge PVC conduit pipe …….dia .......mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structureor rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.25mm dia 2mm thickMtr100.36100.3680.0FalseNoneNoneFalseNoneFalse8028.80
3530407127060NoneElecl code96SRP.2.3.Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694.confirming to latest amendments. 1.5 sqmm 2.3.2Mtr32.2132.211600.0FalseNoneNoneFalseNoneFalse51536.00
3530408127060NoneElecl code97Do- 2.5 sqmm (P6/2.3.3)Mtr52.0452.041400.0FalseNoneNoneFalseNoneFalse72856.00
3530409127060NoneElecl code98Do- 4sqmm (P6/2.3.4)Mtr78.0678.06600.0FalseNoneNoneFalseNoneFalse46836.00
3530410127060NoneElecl code99Do- 6sqmm (P6/2.3.5)Mtr113.99113.99500.0FalseNoneNoneFalseNoneFalse56995.00
3530411127060NoneElecl code100Do- 10sqmm (P6/2.3.6)Mtr206.91206.91120.0FalseNoneNoneFalseNoneFalse24829.20
3530412127060NoneElecl code101Do- 16sqmm(P6/2.3.7)Mtr394.0394.0120.0FalseNoneNoneFalseNoneFalse47280.00
3530413127060NoneElecl code102SRP.2.2.1.Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694. and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr from tapping point to out let via switch boxNo333.29333.2918.0FalseNoneNoneFalseNoneFalse5999.220
3530414127060NoneElecl code103Do- Medium point above 3 Mtr upto 6Mtr from tapping point to outlet via switch box. (P5/2.2.2)No469.58469.5825.0FalseNoneNoneFalseNoneFalse11739.50
3530415127060NoneElecl code104Do- Long point above 6 Mtr upto 10Mtr from tapping point to outlet via switch box. (P5/2.2.3)No687.65687.6540.0FalseNoneNoneFalseNoneFalse27506.00
3530416127060NoneElecl code105Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.1-3Way 3.4.1No170.98170.9820.0FalseNoneNoneFalseNoneFalse3419.60
3530417127060NoneElecl code106Do- 4-5way (P15/3.4.3)No219.3219.315.0FalseNoneNoneFalseNoneFalse3289.50
3530418127060NoneElecl code107Do-6 way (P15/3.4.4)No272.58272.5820.0FalseNoneNoneFalseNoneFalse5451.60
3530419127060NoneElecl code108Do-10-12 way (P15/3.4.6)No395.24395.2440.0FalseNoneNoneFalseNoneFalse15809.60
3530420127060NoneElecl code109Do-18 way (P15/3.4.8)No501.8501.84.0FalseNoneNoneFalseNoneFalse2007.20
3530421127060NoneElecl code110Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.1 to 3 Module 3.5.1No169.74169.7420.0FalseNoneNoneFalseNoneFalse3394.80
3530422127060NoneElecl code111Do- 4 mod (P16/3.5.3)No216.83216.8315.0FalseNoneNoneFalseNoneFalse3252.450
3530423127060NoneElecl code112Do- 6 Module (P16/3.5.4)No289.93289.9320.0FalseNoneNoneFalseNoneFalse5798.60
3530424127060NoneElecl code113Do-10-12 Module (P16/3.5.6)No426.22426.2240.0FalseNoneNoneFalseNoneFalse17048.80
3530425127060NoneElecl code114Do-18 Module (P16/3.5.8)No566.22566.224.0FalseNoneNoneFalseNoneFalse2264.880
3530426127060NoneElecl code115Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch 3.6.1No126.38126.38280.0FalseNoneNoneFalseNoneFalse35386.40
3530427127060NoneElecl code116Do- 6Amps 3 way socket (P16/3.6.3)No211.87211.8724.0FalseNoneNoneFalseNoneFalse5084.880
3530428127060NoneElecl code117Do- modular stepped fan regulator (P16/3.6.4)No442.32442.3212.0FalseNoneNoneFalseNoneFalse5307.840
3530429127060NoneElecl code118Do- 16Amps one way switch (P16/3.6.7)No223.02223.0211.0FalseNoneNoneFalseNoneFalse2453.220
3530430127060NoneElecl code119Do- 6/16 Amps universal socket (P16/3.6.10)No292.4292.411.0FalseNoneNoneFalseNoneFalse3216.40
3530431127060NoneElecl code120Supplying and fixing Fan box with round hook (P3/1.13)No144.96144.9612.0FalseNoneNoneFalseNoneFalse1739.520
3530432127060NoneElecl code121Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely 25mm 1.9.2Mtr27.2627.2660.0FalseNoneNoneFalseNoneFalse1635.60
3530433127060NoneElecl code122Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70percentage lumen maintenance with CRI more than 80. Power Input. 220-240V @ 50/60Hz & Power factor more than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.11.3.2 LED light fighting 1 x4feet- 20/22 wNo854.91854.9140.0FalseNoneNoneFalseNoneFalse34196.40
3530434127060NoneElecl code12311.5.3. Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70percentage lumen maintenance with CRI more than 80. Power Input. 220-240V @ 50/60Hz & Power factor more than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18WNo1640.441640.445.0FalseNoneNoneFalseNoneFalse8202.20
3530435127060NoneElecl code124Supplying of recess mounting non integral type ........LED ...... W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded fase ceiling clamps, Power LEDs with CCT 6500 degree K, CRImore than 70percentage. Efficacy more than100 lumen per watt, 120degree beam spread, lifemore than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF more than 0.95, power loss should Less than 5percentage of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, , THD less than 20percentage, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2feetx2feet / 1feet x 4feet 34 -36watt 12.6.2No5641.175641.1715.0FalseNoneNoneFalseNoneFalse84617.550
3530436127060NoneElecl code12511.8.4 Supply of LED Streetlight luminaire 90 watt with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70percentage, maximum light intensity should be between 60 degrees to 70 degrees. CCT more than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire more than IK08. Power Factor more than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiencymore than130lm/w, nominal CRI more than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001.2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/Lumileds/Osram make LED Source.LED Streetlight 90 WattsNo10977.5410977.5420.0FalseNoneNoneFalseNoneFalse219550.80
3530437127060NoneElecl code1266.3.1..Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system.No3697.183697.1810.0FalseNoneNoneFalseNoneFalse36971.80
3530438127060NoneElecl code1276.2.1.Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete.12" Sweep (300mm) 7.2.1No3678.593678.598.0FalseNoneNoneFalseNoneFalse29428.720
3530439127060NoneElecl code128Fixing all types and all capacities of fluorescent / false ceiling/ spot light / CFL / LED fittings indoor on the wall / ceiling /rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.On wall / ceiling / Rafter / Girders 13.7.1No151.16151.1640.0FalseNoneNoneFalseNoneFalse6046.40
3530440127060NoneElecl code129Supplying and Fixing........mm dia class A GI pipe bracket up to 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires.Using 40mm dia G.I.Pipe 13.2.3No1831.241831.246.0FalseNoneNoneFalseNoneFalse10987.440
3530441127060NoneElecl code1306.5.1.Supplying wall mounting fan suitable to operate at singlephase 230v A.C. supply.No3087.593087.5915.0FalseNoneNoneFalseNoneFalse46313.850
3530442127060NoneElecl code131Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing feetSfeet hook with fan regulator to the existing board together with supplying and fixing 5 amps. Ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.13.10No211.87211.876.0FalseNoneNoneFalseNoneFalse1271.220
3530443127060NoneElecl code132Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.13.13No875.97875.973.0FalseNoneNoneFalseNoneFalse2627.910
3530444127060NoneElecl code133Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and feetCfeet Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.5.18.1 6-32Amps SPNo514.19514.1940.0FalseNoneNoneFalseNoneFalse20567.60
3530445127060NoneElecl code134Do- 6-32 Amps DP. (5.18.2)No915.62915.6225.0FalseNoneNoneFalseNoneFalse22890.50
3530446127060NoneElecl code135Do- 6-32 Amps TPN. (5.18.7)No2127.362127.368.0FalseNoneNoneFalseNoneFalse17018.880
3530447127060NoneElecl code136Do- 50-63Amps TPN . (5.18.9)No3826.033826.032.0FalseNoneNoneFalseNoneFalse7652.060
3530448127060NoneElecl code13711.2.1.Supplying & fixing retrofit type -PL- LED Lamp .......W LED linear source with CCT 6500 degree K, CRImore than 70percentage. efficacy more than80 lumen per watt, lifemore than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF more than 0.95, power loss should Less than 5percentage of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20percentage, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.Each771.9771.95.0FalseNoneNoneFalseNoneFalse3859.50
3530449127060NoneElecl code138Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (Icu = Ics) 5.14.9 160Amps 25kA.No16660.8316660.836.0FalseNoneNoneFalseNoneFalse99964.980
3530450127060NoneElecl code1395.30.Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 20A single phase Class-1 Accuracy with Temper Proof Energy Meter.No1765.581765.5812.0FalseNoneNoneFalseNoneFalse21186.960
3530451127060NoneElecl code140Supplying, fixing and wiring 3 Phase Digital Ammeter /Voltmeter.5.29No696.32696.321.0FalseNoneNoneFalseNoneFalse696.320
3530452127060NoneElecl code141Supplying, fixing and wiring 50/5Amps to 400/5 Amps 5VA burden current transformer. 0.5 accuracy. (5.34)No638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3530453127060NoneElecl code142Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v AC 50Hz 12/24v DC (5.38)No639.32639.323.0FalseNoneNoneFalseNoneFalse1917.960
3530454127060NoneElecl code143Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.14SWG 5.42.1 (Unit Sqcm)Sqm0.630.63100000.0FalseNoneNoneFalseNoneFalse63000.00
3530455127060NoneElecl code144Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.100Amps 4x30x6mm Aluminium Strips 5.40.1Rmtr3054.143054.141.0FalseNoneNoneFalseNoneFalse3054.140
3530456127060NoneElecl code145Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.40x40x6mm 5.41.1Rmtr377.9377.912.0FalseNoneNoneFalseNoneFalse4534.80
3530457127060NoneElecl code14612.56.Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipmentfeets on the meter board using 40 mm dia2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm diaNo4348.894348.8915.0FalseNoneNoneFalseNoneFalse65233.350
3530458127060NoneElecl code14712.58.2.Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.25x3mm GI strip.Rmtr101.6101.630.0FalseNoneNoneFalseNoneFalse3048.00
3530459127060NoneElecl code148Gescom sr/11KV materials/134/18.01.LT Distribution Box for 100 kVA DTC with MCCBfeets (Sheet Metal) (Dwg No. BESCOM/GM/QS&S/58 Dtd 24.11.2018)Each28107.9528107.953.0FalseNoneNoneFalseNoneFalse84323.850
3530460127060NoneElecl code149Gescom sr/11KV materials/207/32.11. 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm)Km221747.55221747.550.36FalseNoneNoneFalseNoneFalse79829.1180
3530461127060NoneElecl code150Gescom sr/11KV Labour/176/21.06. Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 to 95 SqmmKm38581.2238581.220.1FalseNoneNoneFalseNoneFalse3858.1220
3530462127060NoneElecl code151Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes.6.17.1No3.723.72180.0FalseNoneNoneFalseNoneFalse669.60
3530463127060NoneElecl code152Do- 2.5 sqmm. (6.17.2)No4.964.96220.0FalseNoneNoneFalseNoneFalse1091.20
3530464127060NoneElecl code153Do- 4.0 sqmm. (6.17.3)No4.964.9660.0FalseNoneNoneFalseNoneFalse297.60
3530465127060NoneElecl code154Do- 6 sqmm. (6.17.4)No8.678.6724.0FalseNoneNoneFalseNoneFalse208.080
3530466127060NoneElecl code155Do- 10sqmm.(6.17.5)No9.919.9124.0FalseNoneNoneFalseNoneFalse237.840
3530467127060NoneElecl code156Do- 16 sqmm. (6.17.6)No15.4115.4112.0FalseNoneNoneFalseNoneFalse184.920
3530468127060NoneElecl code157Do- 50 sqmm Long Barrel. (6.17.9)No74.3474.3416.0FalseNoneNoneFalseNoneFalse1189.440
3530469127060NoneElecl code158VOL-5/10.1.4.Supplying PVC ringtite pipes conforming to IS 4985.2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for.PVC pipes 63mm dia., 6 kg/sqcm & class 3Mtr199.48199.48100.0FalseNoneNoneFalseNoneFalse19948.00
3530470127060NoneElecl code159Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy.5.33Each11541.2911541.291.0FalseNoneNoneFalseNoneFalse11541.290
3530471127060NoneElecl code160VOl-6/KPTCL/P.No-158.Jelly Spreading (20-25 mm) . Supplying and providing jelly in the station yard of uniform thickness of 100 mm including the cost of materials, labour charges, required tools and plants etc., complete.Work shall be carried out as per the instructions of Engineerin-charge of works as per the standard procedureCum2196.752196.752.0FalseNoneNoneFalseNoneFalse4393.50
3530472127060NoneElecl code161Gescom sr/11KV materials/536/66.04.HDPE/PLB Pipe 50/42 mmKm105332.35105332.350.14FalseNoneNoneFalseNoneFalse14746.5290
3530473127060NoneElecl code162PWD SR/Vol-5/13.11.5.Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 3 HP 3.00 HP - 90 LPM @ 66 m = 6 STG Outlet Dia - 2.00”Each34832.0134832.011.0FalseNoneNoneFalseNoneFalse34832.010
3530474127060NoneElecl code163PWD SR/Vol-5/12.28.Labour charges for Erection of new / repaired submersible pump set along with GI pipes (32mm / 50mm), cable (New submersible pump set if required will be supplied by the department free of cost and released pump set should be handed over to department) including transportation (Each length = 6 m)Job231.69231.6915.0FalseNoneNoneFalseNoneFalse3475.350
3530475127060NoneElecl code1642.6.2.Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13.8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 V as per IS-694.2010.Mtr208.15208.15140.0FalseNoneNoneFalseNoneFalse29141.00
3530476127060NoneElecl code1655.1.Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230/440 V 1/3 phase motor upto 5 HP.Each2387.552387.551.0FalseNoneNoneFalseNoneFalse2387.550
3530477127060NoneElecl code166Gescom SR/SSM 11KV/88/12.04.Distribution Transformer - 3 Phase, 11kV/433V - Stacked CRGO Core with Oil as per IS-1180 (Part-1). 2014No226173.26226173.261.0FalseNoneNoneFalseNoneFalse226173.260
3530478127060NoneElecl code167Gescom SR/11KV Labour/72/8.01. Erection of 25 to 63 kVA Transformer on Transformer StructureNo1478.131478.131.0FalseNoneNoneFalseNoneFalse1478.130
3530479127060NoneElecl code168Gescom SR/SSM 11KV/289/41.01. Load Break Switch with PanelNo90743.1290743.125.0FalseNoneNoneFalseNoneFalse453715.60
3530480127060NoneElecl code169Gescom SR/SSM 11KV/1/1.01.RCC Pole - 9 Mtr Long, 145 Kg WLNo8767.168767.162.0FalseNoneNoneFalseNoneFalse17534.320
3530481127060NoneElecl code170Gescom SR/11KV Labour/30/2.02.Erection of RCC/PSCC Pole of 9 to 10 Mtr long in a pit of 1.8 Mtr depthNo1379.011379.012.0FalseNoneNoneFalseNoneFalse2758.020
3530482127060NoneElecl code171Gescom SR/SSM 11KV/11/2.01.11 kV, Horizontal Cross Arm - Mild Steel (MS)(Dwg No. BESCOM/GM/QS&S/04 Dtd 24.11.2018)No460.92460.924.0FalseNoneNoneFalseNoneFalse1843.680
3530483127060NoneElecl code172Gescom SR/11KV Labour/51/5.03.Fixing of V-Shape/Horizontal cross arm including Single Top Support Brace and Insulator fixingNo318.42318.424.0FalseNoneNoneFalseNoneFalse1273.680
3530484127060NoneElecl code173Gescom SR/SSM 11KV/47/6.01.11 kV Ceramic Pin Insulator (Shell only)No102.84102.8412.0FalseNoneNoneFalseNoneFalse1234.080
3530485127060NoneElecl code174Gescom SR/SSM 11KV/55/6.09.DISC Insulator 45 kN PorcelainNo631.89631.8912.0FalseNoneNoneFalseNoneFalse7582.680
3530486127060NoneElecl code175Gescom SR/SSM 11KV/166/24.01.11 kV, 200 Amps Single Break GOS (Dwg No. BESCOM/GM/QS&S/23 Dtd 24.11.2018)No11708.5511708.551.0FalseNoneNoneFalseNoneFalse11708.550
3530487127060NoneElecl code176Gescom SR/11KV Labour/97/13.02.Fixing of GOS including wiring (11 kV Single Break 200 Amps)No1367.861367.861.0FalseNoneNoneFalseNoneFalse1367.860
3530488127060NoneElecl code177Gescom SR/SSM 11KV/39/5.09, 5.11, 5.12, 5.13, 5.14, 5.16. Guy Clamp - MS (Dwg No. BESCOM/GM/QS&S/07 Dtd 24.11.2018)Turn Buckle (GI) (Dwg No. BESCOM/GM/QS&S/07 Dtd 24.11.2018)Anchor Rod using 12 mm rounds/Guy Rod - MS (Dwg No. BESCOM/GM/QS&S/07 Dtd 24.11.2018)MS Fish Plate Strain Clamp, 3 Bolt type for 70/90 kN Disc InsulatorNo2106.32106.33.0FalseNoneNoneFalseNoneFalse6318.90
3530489127060NoneElecl code178Gescom SR/11KV Labour/58/5.10.Fixing of GUY Set with break insulator making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT)No329.57329.573.0FalseNoneNoneFalseNoneFalse988.710
3530490127060NoneElecl code179Gescom SR/SSM 11KV/137/19.01. 9 kV, 5 kA Lightning Arrester Metal Oxide Ceramic type with GROUND DISCONNECTOR (Dwg No. BESCOM/GM/QS&S/26 Dtd 24.10.2007)Set1139.881139.881.0FalseNoneNoneFalseNoneFalse1139.880
3530491127060NoneElecl code180Gescom SR/11KV Labour/101/13.06.Fixing of 3 Nos Lightning Arrestor including wiringSet147.44147.441.0FalseNoneNoneFalseNoneFalse147.440
3530492127060NoneElecl code181Gescom SR/SSM 11KV/139/20.01.11 kV, HG Fuse Unit with Solid Core Insulator (Dwg No. BESCOM/GM/QS&S/21 Dtd 24.11.2018)Set1324.491324.491.0FalseNoneNoneFalseNoneFalse1324.490
3530493127060NoneElecl code182Gescom SR/11KV Labour/96/13.01.Fixing DOLO Cutout/Horn Gap Fuse including fixing of cross arm and wiringSet293.64293.641.0FalseNoneNoneFalseNoneFalse293.640
3530494127060NoneElecl code183Gescom SR/SSM 11KV/59/7.02.Rabbit ACSR (6/3.35 mm Al + 1/3.35 mm St), Std Wt. 214 Kg/KMKm57283.9357283.931.0FalseNoneNoneFalseNoneFalse57283.930
3530495127060NoneElecl code18415.111.Supplying of four bucket stand alongwith buckets. CompleteNo2292.152292.152.0FalseNoneNoneFalseNoneFalse4584.30
3530496127060NoneElecl code18515.117.Supplying and installation of RUBBER MAT 1mtr x 1mtr -1Omm thick.complete including cost of materials, labour, usage charges of machinery complete as per specifications.No2354.12354.12.0FalseNoneNoneFalseNoneFalse4708.20
3530497127060NoneElecl code18615.113.Supplying of Hand gloves. completePair1208.031208.032.0FalseNoneNoneFalseNoneFalse2416.060
3530498127060NoneElecl code18715.114.Supplying of first aid box. completeNo743.4743.42.0FalseNoneNoneFalseNoneFalse1486.80
3530499127060NoneElecl code18815.116.Supplying of FIRST AID CHART with lamination. CompleteNo495.6495.62.0FalseNoneNoneFalseNoneFalse991.20
3530500127060NoneElecl code189Ges SR/SSM 11KV/593/68.17.Caution/Danger BoardNo185.85185.856.0FalseNoneNoneFalseNoneFalse1115.10
3530501127060NoneElecl code19021-22/Vol-4/Part-B/Lift Irrigation/4.41.Providing and fixing chain link fencing consisting of 3 m long 65 x 65 x 6 mm M.S angles with top 50 cm bent at 30 degree to vertical fixed at 2.5 m intervals in C.C 1 . 3 . 6 proportion using 20 mm down graded coarse aggregate for 70 cm depth, fixing 50 x 50 mm opening 8 gauge G.I chain link mesh upto 1.8 m height of poles using 8 gauge stretcher wire at top and bottom and 30 x 30 x 5 mm M.S angles with bolts /nuts / washers ( 4 bolts for each pole ), fixing 3 rows of 12 gauge ( 4 barbs at 7.5 cm c/c ) G.I barbed wire for top bent portion of poles, including cost of all materials, machinery, labour, excavation of pit, mixing and laying concrete, curing, drilling holes in angles, cleaning angles, painting angles and Chain links with 2 coats of synthetic enamel paint over a coat of primer etc., complete with all lead and lifts.Sqm1704.861704.8624.0FalseNoneNoneFalseNoneFalse40916.640
3530502127060NoneElecl code1915.20.2.Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board.No5648.65648.61.0FalseNoneNoneFalseNoneFalse5648.60
3530503127060NoneElecl code192Do- 63 Amps 4 pole (5.20.3)No6514.666514.661.0FalseNoneNoneFalseNoneFalse6514.660
3530504127060NoneElecl code1935.12.4.Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution) 200 ANo18893.5118893.511.0FalseNoneNoneFalseNoneFalse18893.510
3530505127060NoneElecl code194Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts,nuts etc., with provision for fixing suitable type capacity MCBfeets single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.5.19.6 4Way SP &NNo1888.241888.2420.0FalseNoneNoneFalseNoneFalse37764.80
3530506127060NoneElecl code195Do- 8way SP &N.(5.19.8) Double door.No2297.112297.112.0FalseNoneNoneFalseNoneFalse4594.220
3530507127060NoneElecl code196Do- 12way SP &N. (5.19.9) Double door.No2885.632885.632.0FalseNoneNoneFalseNoneFalse5771.260
3530508127060NoneElecl code197Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (Icu = Ics) 5.15.11 160Amps 25kA.No16660.8316660.832.0FalseNoneNoneFalseNoneFalse33321.660
3530509127060NoneElecl code1985.29.Supplying, fixing and wiring 3 Phase Digital Ammeter /Voltmeter.No1765.581765.581.0FalseNoneNoneFalseNoneFalse1765.580
3530510127060NoneElecl code199Supplying, fixing and wiring 50/5Amps to 400/5 Amps 5VA burden current transformer. 0.5 accuracy. (5.34)No696.32696.326.0FalseNoneNoneFalseNoneFalse4177.920
3530511127060NoneElecl code200Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v AC 50Hz 12/24v DC (5.38)No638.09638.096.0FalseNoneNoneFalseNoneFalse3828.540
3530512127060NoneElecl code201PWD SR/Vol-2/11.16.1.Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg168.5168.5340.0FalseNoneNoneFalseNoneFalse57290.00
3530513127060NoneElecl code20212.57.Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.12.57No5273.185273.184.0FalseNoneNoneFalseNoneFalse21092.720
3530514127060NoneElecl code203Gescom SR/SSM 11KV/61/8.02.8 SWG GI Wire (4.064 mm Dia), Std Wt. 131 Kg/KMKm92974.5692974.560.04FalseNoneNoneFalseNoneFalse3718.98240
3530515127060NoneElecl code204Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.25x3mm GI strip 12.58.1Mtr101.6101.620.0FalseNoneNoneFalseNoneFalse2032.00
3530516127060NoneElecl code205Gescom sr/SSM 11KV/207/32.11. 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm)Km221747.55221747.552.62FalseNoneNoneFalseNoneFalse580978.5810
3530517127060NoneElecl code206Gescom sr/11KV Labour/176/21.06. Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 to 95 SqmmKm38581.2238581.221.0FalseNoneNoneFalseNoneFalse38581.220
3530518127060NoneElecl code207Vol I/1.14.1.Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1Cum126.38126.38100.0FalseNoneNoneFalseNoneFalse12638.00
3530519127060NoneElecl code208Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes.6.17.1 (2019-20 SR)No3.723.7260.0FalseNoneNoneFalseNoneFalse223.20
3530520127060NoneElecl code209Do- 2.5 sqmm. (6.17.2)No4.964.9680.0FalseNoneNoneFalseNoneFalse396.80
3530521127060NoneElecl code210Do- 4.0 sqmm. (6.17.3)No8.678.6724.0FalseNoneNoneFalseNoneFalse208.080
3530522127060NoneElecl code211Do- 6 sqmm. (6.17.4)No8.678.6724.0FalseNoneNoneFalseNoneFalse208.080
3530523127060NoneElecl code212Do- 10sqmm.(6.17.5)No9.919.9124.0FalseNoneNoneFalseNoneFalse237.840
3530524127060NoneElecl code213Do- 16 sqmm. (6.17.6)No15.4115.4112.0FalseNoneNoneFalseNoneFalse184.920
3530525127060NoneElecl code214Do- 50 sqmm Long Barrel. (6.17.9)No74.3474.3416.0FalseNoneNoneFalseNoneFalse1189.440
3530526127060NoneElecl code215Vol V/191/16.9.onstructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1.6, bed concrete 150mm thick with 1.3.6, plastering 12 mm thick with cement mortar 1.4, CC 1.2.4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.No6757.516757.516.0FalseNoneNoneFalseNoneFalse40545.060
3530527127060NoneElecl code216Vol V/10.1.8.Providing PVC ringtite pipes conforming to IS 4985.2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete 110mmMtr509.23509.23200.0FalseNoneNoneFalseNoneFalse101846.00
3530528127060NoneElecl code217Vol II/09/5.4.(Size stone masonry) Construction of Platform with size stone, cement concrete for errection of Transformer/Metering Cubicle /Heavy equipment. Construction of platform [1.5m x 1.5m x 1.2m] in size srone , for errection of transformer /Heavy equipment including all materials , labour Excavation of [1.5mx1.5mx1m] pit for foundation providing and laying cement concrete 1.4.8 for foundation laid in 10cm thick layers, well compacted curing etc, complete providing and construction of stone masonary 0.9m below ground level and 1.2m above ground level neatly hammer dressed in cement morter 1.6 Providing and Laying cement concrete slab 1.5x1.5x.10mtr with cement concrete of 1.2.4 mix forming & cutting complete , providing pointing to stone masonary in cement morter 1.3 after rackng joint & nisely lining curing etc, plastering the concrete surfaces in cement morter 1.4 including smooth randering curing etc, curing at every stages completely.Cum7915.977915.972.7FalseNoneNoneFalseNoneFalse21373.1190
3530529127060NoneElecl code218Gescom SR/SSM 11KV/398/53.04.LT AC 3 Phase 4 Wire, 5-30 Amps DLMS Complaint Energy Meter, 1.0 Accuracy Class (Used for LT-2, LT-3 & LT-5 Installations up to 25HP/18KW)Each2948.822948.826.0FalseNoneNoneFalseNoneFalse17692.920
3530530127060NoneElecl code2194.1.1.Fabricating, supplying and erecting Swaged tubular Pole of height ...m having three sections, and providing two coats of red oxide paint and finished with two coats of enamelled paint of approved quality and colour and M.S. base plate of suitable size welded at the bottom of the Pole(as per IS) and 40 mm dia GI/flexible PVC pipe of 1m length fitted to the heavy gauge polycarbonate control box including 5 Way connector of size 167 x 125 x 82 mm for 7.5M Pole/ 200 x 160 x 98 mm for remaining length of Pole with front opening cover, with locking arrangements and suitable capacity MCB/DP switch, The Pole shall be erected in cement concrete work (1.2.4) including excavation and refilling of planting depth of the Pole to the ground level and the coping CC shall be upto 0.6m above ground level as per IS2713-7.Erection of heavy duty Pole on Footpath/median 9m (5m Hb,165.1 mm dia 4.85 mm thick x 2m Hm, 139.7 mm dia 4.50 mm thick x 2m Ht,114.3 mm dia 3.65 mm thick) as per IS 410 SP 32No19204.519204.525.0FalseNoneNoneFalseNoneFalse480112.50
3530531127060NoneElecl code22012.8.4 Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70percentage, maximum light intensity should be between 60 degrees to 70 degrees. CCT more than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire more than IK08. Power Factor more than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiencymore than130lm/w, nominal CRI more than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001.2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/Lumileds/Osram make LED Source.LED Streetlight 90 WattsNo10977.5410977.5425.0FalseNoneNoneFalseNoneFalse274438.50
3530532127060NoneElecl code221Gescom sr/SSM 11KV/198/32.02. 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 10 Sqmm, 2 Core, (9 GI Strips - 4 x 0.8 mm)Km98168.4598168.450.5FalseNoneNoneFalseNoneFalse49084.2250
3530533127060NoneElecl code222Gescom sr/11KV Labour/175/21.05. Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 to 25 SqmmKm25877.7525877.750.5FalseNoneNoneFalseNoneFalse12938.8750
3530534127060NoneElecl code223Vol I/1.14.1.Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1Cum126.38126.38120.0FalseNoneNoneFalseNoneFalse15165.60
3530535127060NoneElecl code224Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes.6.17.5 (2019-20 SR)10sqmm.No9.919.9180.0FalseNoneNoneFalseNoneFalse792.80
3530536127060NoneElecl code225Vol V/10.1.8.Providing PVC ringtite pipes conforming to IS 4985.2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete 110mmMtr509.23509.23120.0FalseNoneNoneFalseNoneFalse61107.60
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17211113720000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17211113720000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17211113720000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17211113720000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17211113720000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17211114080000NoneNoneELIGIBILITYShould be a valid Class-I Civil Contractor registered in Karnataka CPWD/MES/KPWD.None
17211114360000NoneNoneELIGIBILITYShould have successfully completed at least one work of similar nature of building work, costing not less than Rs. 200.00 lakhs (Rs. Two hundred lakh) i.e., from 01/04/2019 onwards for any of the Govt./ Public Sector Corporate undertakings.Certificate of completion issued by an officer not below the rank of Executive Engineer, in case of Govt., / Public Sectors under takings.None
17211116340000NoneNoneELIGIBILITYExecuted in any one financial year during last five years i.e 2019-20, 2020-21, 2021-22, 2022-23 & 2023-24 the minimum quantities of work R.C.C M-20/M-25 Work 623.45 Cum, Mild/TMT Steel work 55.93 MT, Brick Masonry 99.67 Cum, Flooring work 680.00 Sqm, M.S Grill 783.00 Kg, M-30/M-40 RCC (Rigid Pavement concrete) 240.00 Cum, Structural Steel 3893.00 Kg, Precoated Galvanised iron profile Sheets 229.00 Sqm, Rolling shutters 81.00 Sqm, Stone work (Machine cut edges) for wall lining (Veneer Work) 28.00 Sqm, Burried Expansion Joint 80.00 Rmt, Floating coat cement plaster 120.00 SqmNone
17211116490000NoneNoneELIGIBILITYShould have achieved a Annual Financial Turnover of Rs. 800.00 Lakhs (Rs. Eight hundred lakh) pertaining to civil works for any of 2 (two) financial years from last preceding Five years i.e (2019-20, 2020-21, 2021-22, 2022-23 & 2023-24).None
17211116600000NoneNoneELIGIBILITYUpload a copy of audited balance sheet and profit & loss accounts statement certified by a Chartered Accountant along with Income Tax Return Acknowledgement for respective Years.None
17211116770000NoneNoneELIGIBILITYTo Qualify for award of this contract the Tenderer has to furnish Liquid assets statement or availability of credit facilities for an amount not less than Rs. 120.00 Lakhs (Rs. One hundred twenty Lakh)- letter of credit issued from any nationalized Bank / Schedule bank (excluding Co-operative banks ) in the prescribed format.None
17211121560000NoneNoneELIGIBILITYUpload Scanned Copy of the Credit Lines / Letters of Credit / Certificates from any nationalized Bank / Schedule bank (excluding Co-operative banks), clearly specifying name of the work (as per the prescribed format) addressed to the Executive Engineer, KKRTC, C.E. Division, Kalaburagi. (Annexure-A)None
17211122720000NoneNoneELIGIBILITYTo Qualify for award of this contract the assessed available Tender capacity of the tenderer should be more than the amount put to tender. Note: The bid capacity of the tenderer is calculated based on the formula as per KTTP Act. Assessed Available Tender Capacity Equal to ( (A X N x 1.5) - B) Where A Equal to Maximum value of Civil Engineering works, updated to 2023-24 price level, executed in any one year during the last five years.( Completed as well as works in progress ).B Equal to Value at 2023-24 price level of existing commitments and ongoing works to be completed during the next two years.N Equeal to Number of years prescribed for completion of the work for which tender is invited. 1.5 Equeal to Multiplying factor for assessing the available tender capacity for works costing more than Rs.100.00 Lakhs.None
17211122820000NoneNoneELIGIBILITYContractor has to upload statement showing the maximum value of Civil Engineering Works executed in any one year, taking into account completed works as well as works in progress, during the last five years and statement of existing commitments and ongoing works as well as the stipulated period of completion remaining for each of the listed works. ( ie. During the years 2019-20, 2020-21, 2021-22 ,2022-23 & 2023-24) (Self Certificate as per the prescribed format , Annexure - B )None
17211122960000NoneNoneELIGIBILITYPerformance security for unbalance Rates Within 20 Days of receipt of letter of acceptance, the successful bidder shall deliver to employer an amount equal to difference of sanctioned and approved bid amount in the form of D.D/ Banker cheque / Bank Guaranty in favour of Executive Engineer KKRTC CE Div Kalaburagi. The same will be refunded after completion of work. (Attach self declaration certificate)None
17211126420000NoneNoneELIGIBILITYDocuments should be attach as per tender Notification (Tender Notification is attached)None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneDocuments should be attach as per tender Notification (Tender Notification is attached)OthersDocuments should be attach as per tender Notification (Tender Notification is attached)
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Documents should be attach as per tender Notification (Tender Notification is attached)
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Should be a valid Class-I Civil Contractor registered in Karnataka CPWD/MES/KPWD.TrueTechnical Bid
Should have successfully completed at least one work of similar nature of building work, costing not less than Rs. 200.00 lakhs Rs. Two hundred lakh i.e., from 01/04/2019 onwards for any of the Govt./ Public Sector Corporate undertakings.Certificate of completion issued by an officer not below the rank of Executive Engineer, in case of Govt./Public Sectors under takingsTrueTechnical Bid
minimum quantities of work R.C.C M-20/M-25 Work 623.45 Cum, Mild/TMT Steel work 55.93 MT, Brick Masonry 99.67 Cum, Flooring work 680.00 Sqm, M.S Grill 783.00 Kg, M-30/M-40 RCC Rigid Pavement concrete 240.00 Cum, Structural Steel 3893.00 Kg, Precoated Galvanised iron profile Sheets 229.00 Sqm, Rolling shutters 81.00 Sqm, Stone work Machine cut edges for wall lining Veneer Work 28.00 Sqm, Burried Expansion Joint 80.00 Rmt, Floating coat cement plaster 120.00 SqmTrueTechnical Bid
Should have achieved a Annual Financial Turnover of Rs. 800.00 Lakhs Rs. Eight hundred lakh pertaining to civil works for any of 2 two financial years from last preceding Five years i.e 2019-20, 2020-21, 2021-22, 2022-23 & 2023-24.TrueTechnical Bid
To Qualify for award of this contract the Tenderer has to furnish Liquid assets statement or availability of credit facilities for an amount not less than Rs. 120.00 Lakhs Rs. One hundred twenty Lakh- letter of credit issued from any nationalized Bank / Schedule bank excluding Co-operative banks in the prescribed format.TrueTechnical Bid
Tender capacity Documents should be attach as per tender Notification Tender Notification is attachedTrueTechnical Bid
Documents should be attach as per tender Notification Tender Notification is attachedTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1721129735000
version0
createdDateNone
modifiedDateNone
blockNumberKKRTC CE DIVISION KALABURAGI
streetNone
cityKALABURAGI
stateKarnataka
pin585101
tenderRecallDTONone