| 3530138 | 127044 | None | code01 | KSRB 1-1.14.1 Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenaces required to complete the work. (Item No. 1.14.1 Page No. 8 Vol.1 PWD SR 2023-24) | Cum | 114.24 | 114.24 | 29.41 | False | None | None | False | None | False | 3359.7984 | 0 |
| 3530139 | 127044 | None | code02 | KSRB 2-2.1.2 Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement and formwork shall be paid separately. Specification No. KBS 2.1, (Item No. 2.1.2 Page No. 15 Vol.1 PWD SRPWD SR 2023-24) | Cum | 6343.68 | 6343.68 | 28.97 | False | None | None | False | None | False | 183776.4096 | 0 |
| 3530140 | 127044 | None | code03 | KSRB 2-2.3.2Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR PWD SR 2023-24) and Appendix I page No.115) Footings | Cum | 7776.0 | 7776.0 | 7.12 | False | None | None | False | None | False | 55365.12 | 0 |
| 3530141 | 127044 | None | code04 | KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR PWD SR 2023-24) & Appendix I page No.115) Column base | Cum | 11016.0 | 11016.0 | 1.63 | False | None | None | False | None | False | 17956.08 | 0 |
| 3530142 | 127044 | None | code05 | KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR PWD SR 2023-24) & Appendix I page No.115) Hall Grade slab | Cum | 7776.0 | 7776.0 | 28.62 | False | None | None | False | None | False | 222549.12 | 0 |
| 3530143 | 127044 | None | code06 | KSRB 2-2.2.3.1 :Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No. 2.2.3 Page No. 15 Vol.1 PWD SR PWD SR 2023-24) & Appendix I page No.115) | Cum | 10264.32 | 10264.32 | 4.82 | False | None | None | False | None | False | 49474.0224 | 0 |
| 3530144 | 127044 | None | code07 | KSRB 2.11 Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (Item No. 2.11 Page No. 18 Vol.1 PWD SRPWD SR 2023-24) | Tonne | 100191.84 | 100191.84 | 2.7731 | False | None | None | False | None | False | 277841.991504 | 0 |
| 3530145 | 127044 | None | code08 | KSRB 5-5.4: Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) . (Item No. 5.4 Page No. 9 Vol.2 PWD SRPWD SR 2023-24) ) | Cum | 7155.6 | 7155.6 | 16.67 | False | None | None | False | None | False | 119283.852 | 0 |
| 3530146 | 127044 | None | code09 | KSRB 1-1.8: Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work (Item No. 1.8 Page No. 7 Vol.1 PWD SRPWD SR 2023-24) ) | Cum | 530.88 | 530.88 | 128.79 | False | None | None | False | None | False | 68372.0352 | 0 |
| 3530147 | 127044 | None | code10 | KSRB 6-6.33: Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Item No. 6.33 Page No. 17 Vol.2 PWD SR 2023-24) ) | Cum | 1378.72 | 1378.72 | 13.66 | False | None | None | False | None | False | 18833.3152 | 0 |
| 3530148 | 127044 | None | code11 | KSRB 8-8.3.1: Providing 15mm/18mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.3.1, Page No. 41, Vol.2 PWD SR 2023-24) ) | Sqm | 330.4 | 330.4 | 187.56 | False | None | None | False | None | False | 61969.824 | 0 |
| 3530149 | 127044 | None | code12 | Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. (Item No. 11.2, Page No. 77, Vol.2PWD SR 2023-24) ) | Kg | 126.56 | 126.56 | 6130.0 | False | None | None | False | None | False | 775812.8 | 0 |
| 3530150 | 127044 | None | code13 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Item No. 7.38, Page No. 26, Vol.2PWD SR 2023-24) ) | Sqm | 636.16 | 636.16 | 518.21 | False | None | None | False | None | False | 329664.4736 | 0 |
| 3530151 | 127044 | None | code14 | KSRB 8-8.51 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(Item No. 8.51, Page No. 50, Vol.2 PWD SR 2023-24) ) | Sqm | 112.0 | 112.0 | 187.56 | False | None | None | False | None | False | 21006.72 | 0 |
| 3530152 | 127044 | None | code15 | KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(Item No. 8.54.1, Page No. 50, Vol.2 PWD SR 2023-24 ) | Sqm | 81.76 | 81.76 | 91.08 | False | None | None | False | None | False | 7446.7008 | 0 |
| 3530153 | 127044 | None | code16 | KSRB 8-8.75.2 : Finishing walls with Premium Acrylic Smooth exterior paint of required shade : Old work (one coats applied @ 0.83 l/10 m²) including preparing the surface after thoroughly cleaning the surface to remove all dirt,dust and foreign matter , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.75.2, Page No. 53, Vol.2PWD SR 2023-24 ) | Sqm | 81.76 | 81.76 | 91.08 | False | None | None | False | None | False | 7446.7008 | 0 |
| 3530154 | 127044 | None | code17 | KSRB 11-11.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Item No. 11.6.1, Page No. 76, Vol.2PWD SR 2023-24 ) | Sqm | 2948.96 | 2948.96 | 9.0 | False | None | None | False | None | False | 26540.64 | 0 |
| 3530155 | 127044 | None | code18 | KSRB 11-11.8.4:Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Item No. 11.8.4, Page No. 77, Vol.2PWD SR 2023-24 ) | Nos | 27648.0 | 27648.0 | 1.0 | False | None | None | False | None | False | 27648.0 | 0 |
| 3530156 | 127044 | None | code19 | KSRB 11-11.35.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications..(Item No. 11.35.1.1, Page No. 87, Vol.2 PWD SR 2023-24) | Sqm | 506.24 | 506.24 | 240.0 | False | None | None | False | None | False | 121497.6 | 0 |
| 3530157 | 127044 | None | code20 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on theexisting plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6m upto 10m from tapping point to out let via switch box (P no.4 i no. 2.1.3) | No | 570.0 | 570.0 | 8.0 | False | None | None | False | None | False | 4560.0 | 0 |
| 3530158 | 127044 | None | code21 | Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 (P No.7 i no 3.1.1) 6A 2 Way | No | 128.0 | 128.0 | 15.0 | False | None | None | False | None | False | 1920.0 | 0 |
| 3530159 | 127044 | None | code22 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall(P No.7 i no 3.4.1) 1-3 Way -do- (P No.7 i no 3.4.1) 4-5 Way | No | 138.0 | 138.0 | 8.0 | False | None | None | False | None | False | 1104.0 | 0 |
| 3530160 | 127044 | None | code23 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall(P No.7 i no 3.4.3) 1-3 Way -do- (P No.7 i no 3.4.3) 4-5 Way | No | 177.0 | 177.0 | 4.0 | False | None | None | False | None | False | 708.0 | 0 |
| 3530161 | 127044 | None | code24 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall(P No.7 i no 3.4.4) 1-3 Way -do- (P No7 i no 3.4.4) 6 Way | No | 220.0 | 220.0 | 8.0 | False | None | None | False | None | False | 1760.0 | 0 |
| 3530162 | 127044 | None | code25 | Supplying of feet -PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours and 70 lumen maintenance with CRI 80. Power Input 220240V at 50 60Hz and Power factor less than 0.9 along with CE approved 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1inch 4inch 36 40 W P No 42 i no 11.1 | No | 1291.0 | 1291.0 | 6.0 | False | None | None | False | None | False | 7746.0 | 0 |
| 3530163 | 127044 | None | code26 | Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230/440 V 1/3 phase motor upto 5 HP. (P No.13 i no.5.1) | No | 1927.0 | 1927.0 | 3.0 | False | None | None | False | None | False | 5781.0 | 0 |
| 3530164 | 127044 | None | code27 | Supplying fully automatic star-delta starter unit push button type with suitable wires, 3 contactors, one adjustable thermal timer mounted on a common base plate held in steel enclosure for use on 400/440 V 3 phase and wired after fixing to the existing wooden board for motor. (P No.13 i no.5.2)upto 12.5 HP | No | 7455.0 | 7455.0 | 3.0 | False | None | None | False | None | False | 22365.0 | 0 |
| 3530165 | 127044 | None | code28 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws. a)(P NO 13 I no. 5.6.4) 12" x 12" x 2" | No | 181.0 | 181.0 | 2.0 | False | None | None | False | None | False | 362.0 | 0 |
| 3530166 | 127044 | None | code29 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws. b)(P NO 13 I no. 5.6.5) 15" x 12" x 2" | No | 201.0 | 201.0 | 2.0 | False | None | None | False | None | False | 402.0 | 0 |
| 3530167 | 127044 | None | code30 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.c)(P NO 13 I no. 5.6.6) 20" x 20" x 2.5" | No | 326.13 | 326.13 | 2.0 | False | None | None | False | None | False | 652.26 | 0 |
| 3530168 | 127044 | None | code31 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. (P a)NO 13 I no. 5.7.2) 32 A | No | 241.0 | 241.0 | 3.0 | False | None | None | False | None | False | 723.0 | 0 |
| 3530169 | 127044 | None | code32 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. (P b)(P NO 13 I no. 5.7.3) 63 A | No | 401.0 | 401.0 | 3.0 | False | None | None | False | None | False | 1203.0 | 0 |
| 3530170 | 127044 | None | code33 | Supplying and fixing Moulded Case Circuit Breaker mccb over the existing wood panel board using necessary screws bolts nuts necessary phase separators handle and wiring complete Protection of Overload and Short circuit in Thermal Magnetic Release Micro processor release shall have Earth Fault as per IS 13947 Icu 100 l cs In 4P mccb all Poles should have protection for Short Cicrcuit Over Load For Microprocessor mccb Facility for segregating Priority and Non Priority loads must be available in the mccb mccb shall be provided with double insulation insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open Multi pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism P No 16 i no 5.15.9 100 A 25 | No | 8487.0 | 8487.0 | 6.0 | False | None | None | False | None | False | 50922.0 | 0 |
| 3530171 | 127044 | None | code34 | Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694 confirming to latest amendments. P no.4 I no. 2.3.3 2.5 sqmm | Mtr | 42.0 | 42.0 | 240.0 | False | None | None | False | None | False | 10080.0 | 0 |
| 3530172 | 127044 | None | code35 | Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694 confirming to latest amendments. P no. 4 I no. 2.3.4 4 sqm | Mtr | 63.0 | 63.0 | 230.0 | False | None | None | False | None | False | 14490.0 | 0 |
| 3530173 | 127044 | None | code36 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS- 694:2010 (P NO 5 I No.2.5.9) 4C x 2.5 mm2 | Mtr | 148.0 | 148.0 | 260.0 | False | None | None | False | None | False | 38480.0 | 0 |
| 3530174 | 127044 | None | code37 | Earthing materials pipe type for grounding Single Electrode with accessories Hescom 2023-24 | No | 1729.0 | 1729.0 | 6.0 | False | None | None | False | None | False | 10374.0 | 0 |
| 3530175 | 127044 | None | code38 | Labour Charges | LS | 949.0 | 949.0 | 6.0 | False | None | None | False | None | False | 5694.0 | 0 |
| 3530176 | 127044 | None | code39 | Main Control Board 3 Phase a) 63 Amps Porcelien base fues b)20mm water proof flywood 3'x4'c)50mm MS Angle 8'd)32 Amp 4way Distribution boarde)Flexible hose pipe and GI clampsf)Energy Meter Board including complete suitable wiring | Job | 20000.0 | 20000.0 | 1.0 | False | None | None | False | None | False | 20000.0 | 0 |
| 3530177 | 127044 | None | code40 | HESCOM Charges a) Security deposit, Energy meter cost, supervision charges, development charges, with establishbment and document charges (for 6 KW Load) | Job | 28000.0 | 28000.0 | 1.0 | False | None | None | False | None | False | 28000.0 | 0 |