createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1719985446751
version6
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee3180.00
emd200000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose25-07-2024 16:00:00
tenderQueryClose24-07-2024 16:00:00
technicalBidOpen26-07-2024 16:30:00
publishedDate16-07-2024 16:13:25
publishedByPostPWD_EE_DIV_HSPT
publishedByUserKPE10057 - DEVADASA T
bidValidityPeriod90
noOfCalls1
preBidMeetingDate17-07-2024 13:19:15
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonExecutive Engineer
splitEmdRequiredYnTrue
emdBankGuarantee100000.00
emdCash100000.00
bgValidityPeriod135
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber080394200231
mobileNumberNone
tenderSupplierListNone
tenderSchedule
createdTs1719985446783
version12
createdDateNone
modifiedDateNone
tenderNumberPWD/2024-25/BD/WORK_INDENT10844
titleConstruction Of Vakeelara Bhavana At Kudligi, Vijayanagar District,(Appendix e , 4059 Court Buildings)
descriptionConstruction Of Vakeelara Bhavana At Kudligi, Vijayanagar District,(Appendix e , 4059 Court Buildings)
categoryWORKS
categoryTextWorks
ecv12706885.17
deptNamePublic Works Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location1694
locationNamePWD Division Office Hosapete
provisionalAmount15000000.0
groupOverheadTotal0.0
fileNumberAEE/PWD/KDL/court/building/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17199854470001NoneNoneBuildingsGROUND FLOOR ESTIMATION5388402.36
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3438918121980NoneCSR 2023-24 Vol-2, P.NO -163, SL.No -19.9.1Demolishing stone rubble masonry manually/ by mechanical means Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineerin-charge. In lime mortar (CSR 2023-24 Vol-2, P.NO -163, SL.No -19.9.1)Cum831.6831.623.9FalseNoneNoneFalseNoneFalse19875.240
3438919121980NoneCSR 2023-24 Vol-2, P.NO -193, SL.No -19.57Demolishing R.C.C. Work Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials to the appropriate disposal area stacking serviceable and unserviceable material separately including cutting reinforcement bars.(CSR 2023-24 Vol-2, P.NO -193, SL.No -19.57) Cum2466.452466.4529.57FalseNoneNoneFalseNoneFalse72932.92650
3438920121980NoneCSR 2023-24 Vol-2, P.NO -187, SL.No -19.7.3Demolishing brick work Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.In cement mortar (CSR 2023-24 Vol-2, P.NO -187, SL.No -19.7.3) Cum1080.451080.45186.57FalseNoneNoneFalseNoneFalse201579.55650
3438921121980NoneCSR 2023-24 Vol-2, P.NO -191, SL.No -19.40Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials to the appropriate disposal area as per direction of Engineerin- charge (CSR 2023-24 Vol-2, P.NO -191, SL.No -19.40)Sqm37.837.8150.0FalseNoneNoneFalseNoneFalse5670.00
3438922121980NoneCSR 2023-24 - Item No - 1.14.1 , Page No - 8 Vol -Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ( CSR 2023-24 - Item No : 1.14.1 , Page No - 8 Vol -1 )Cum107.1107.1333.92FalseNoneNoneFalseNoneFalse35762.8320
3438923121980NoneCSR 2023-24 - Item No -2.1.3 , Page No - 15 Vol 1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregatesCum6288.456288.4535.74FalseNoneNoneFalseNoneFalse224749.2030
3438924121980NoneCSR 2023-24,Vol-2, SL.No. 5.3, p. No.9Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (CSR 2023-24,Vol-2, SL.No. 5.3, p. No.9)Cum6515.256515.2521.94FalseNoneNoneFalseNoneFalse142944.5850
3438925121980NoneCSR 2023-24, Vol-2 SL.No. 5.4, P. No. 9Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.4544.56FalseNoneNoneFalseNoneFalse298928.5320
3438926121980NoneSR 2023-24, Vol-2,SL.No. 8.3.1, P. No.41Providing 20 mm cement plaster of mix :1:4 Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (SR 2023-24, Vol-2,SL.No. 8.3.1, P. No.41)Sqm371.7371.778.26FalseNoneNoneFalseNoneFalse29089.2420
3438927121980NoneCSR 2023-24 , I.No : 2.4.3 , Page No : 16 ,V-1RCC works M25 For Foundation work Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Cum6652.86652.869.09FalseNoneNoneFalseNoneFalse459641.9520
3438928121980NoneFormworkPercentage Additionalities for Formwork, Centering & Scaffolding ( SR 2023-24 , Addendum I , Page No : 111 , Vol 1 . ) Percentage on finished rate of concrete per m3Cum532.22532.2269.09FalseNoneNoneFalseNoneFalse36771.07980
3438929121980NoneCSR 2023-24 , I No : 2.4.3 , Page No : 16 , Vol -1RCC works M25 For Foundation work Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Columns upto Plinth Beam BottomCum6652.86652.87.22FalseNoneNoneFalseNoneFalse48033.2160
3438930121980NoneFormworkPercentage Additionalities for Formwork, Centering & Scaffolding ( SR 2023-24 , Addendum I , Page No : 111 , Vol 1 . ) Percentage on finished rate of concrete per m3Cum4656.964656.967.22FalseNoneNoneFalseNoneFalse33623.25120
3438931121980NoneCSR 2023-24 , I No : 2.4.3 , Page No : 16 , Vol 1RCC works M25 For Foundation work Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Plinth BeamCum6652.86652.812.71FalseNoneNoneFalseNoneFalse84557.0880
3438932121980NoneFormwork for 50 percentPercentage Additionalities for Formwork, Centering & Scaffolding ( SR 2023-24 , Addendum I , Page No : 111 , Vol 1 . ) Percentage on finished rate of concrete per m3 Cum3326.43326.412.71FalseNoneNoneFalseNoneFalse42278.5440
3438933121980NoneCSR 2023-24 , I No : 2.4.3 , Page No : 16 , Vol 1RCC works M25 For Foundation work Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Cum6652.86652.85.18FalseNoneNoneFalseNoneFalse34461.5040
3438934121980NoneFormwork for 50 percentPercentage Additionalities for Formwork, Centering & Scaffolding ( SR 2023-24 , Addendum I , Page No : 111 , Vol 1 . ) Percentage on finished rate of concrete per m3 Cum3326.43326.45.18FalseNoneNoneFalseNoneFalse17230.7520
3438935121980NoneCSR 2023-24 , I No : 2.5.2 , Page No : 16 , Vol -1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7185.157185.1512.21FalseNoneNoneFalseNoneFalse87730.68150
3438936121980NoneFormwork for 70 percentPercentage Additionalities for Formwork, Centering & Scaffolding ( SR 2023-24 , Addendum I , Page No : 111 , Vol 1 . ) Percentage on finished rate of concrete per m3 Cum5029.615029.6112.21FalseNoneNoneFalseNoneFalse61411.53810
3438937121980NoneCSR 2023-24 , I No : 2.5.2 , Page No : 16 , Vol -1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7185.157185.156.31FalseNoneNoneFalseNoneFalse45338.29650
3438938121980NoneFormwork for 60 percentPercentage Additionalities for Formwork, Centering & Scaffolding ( SR 2023-24 , Addendum I , Page No : 111 , Vol 1 . ) Percentage on finished rate of concrete per m3 Cum4311.094311.096.31FalseNoneNoneFalseNoneFalse27202.97790
3438939121980NoneCSR 2023-24 , I No : 2.5.2 , Page No : 16 , Vol 1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7185.157185.1518.8FalseNoneNoneFalseNoneFalse135080.820
3438940121980NoneFormwork for 60 percentPercentage Additionalities for Formwork, Centering & Scaffolding ( SR 2023-24 , Addendum I , Page No : 111 , Vol 1 . ) Percentage on finished rate of concrete per m3Cum4311.094311.0918.8FalseNoneNoneFalseNoneFalse81048.4920
3438941121980NoneCSR 2023-24 , I No : 2.5.2 , Page No : 16 , Vol 1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Cum7185.157185.1555.47FalseNoneNoneFalseNoneFalse398560.27050
3438942121980NoneFormworkPercentage Additionalities for Formwork, Centering & Scaffolding ( SR 2023-24 , Addendum I , Page No : 111 , Vol 1 . ) Percentage on finished rate of concrete per m3 Cum3592.583592.5855.48FalseNoneNoneFalseNoneFalse199316.33840
3438943121980NoneCSR 2023-24 , I No : 2.5.2 , Page No : 16 , Vol 1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7185.157185.153.22FalseNoneNoneFalseNoneFalse23136.1830
3438944121980NoneFormwork work for 50 percentPercentage Additionalities for Formwork, Centering & Scaffolding ( SR 2023-24 , Addendum I , Page No : 111 , Vol 1 . ) Percentage on finished rate of concrete per m3Cum3592.583592.583.22FalseNoneNoneFalseNoneFalse11568.10760
3438945121980NoneCSR 2023-24 , I No : 2.11 a, Page No : 18 , Vol 1Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification, a. Buildingst93929.8593929.8518.72FalseNoneNoneFalseNoneFalse1758366.7920
3438946121980NoneCSR 2023-24,Vol-1 SL.No. 1.9, P. No. 34Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (CSR 2023-24,Vol-1 SL.No. 1.9, P. No. 34)Cum279.3279.3164.21FalseNoneNoneFalseNoneFalse45863.8530
3438947121980NoneCSR 2023-24, Vol-1, SI.No.1.8, P.No -33Construction of Embankment Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage & all other appurtenaces required to complete the work (CSR 2023-24, Vol-1, SI.No.1.8, P.No -33)Cum497.7497.769.91FalseNoneNoneFalseNoneFalse34794.2070
3438948121980NoneSR 2023-24 Item No : 2.1.3 , Page No : 15 Vol 1P/L Floor Bed PCC of mix 1:3:6 (M 10) Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ( SR 2023-24 / Item No : 2.1.3 , Page No : 15 Vol 1)Cum6288.456288.4525.96FalseNoneNoneFalseNoneFalse163248.1620
3438949121980NoneCSR 2023-24, Vol-2, SL.No. 6.2, Pg. No. 13Providing Brick work with common burnt clay Non Modular bricks Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (CSR 2023-24, Vol-2, SL.No. 6.2, Pg. No. 13)Cum8376.98376.921.79FalseNoneNoneFalseNoneFalse182532.6510
3438950121980NonePWD SR 2023-24 Ballari Circle Item No.8.6.1Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerin- charge. (PWD SR 2023-24 Ballari Circle Item No.8.6.1, Page No.42 Vol 2)Sqm339.15339.1528.2FalseNoneNoneFalseNoneFalse9564.030
3438951121980NonePWD SR 2023-24 Ballari Circle Item No.8.9, Page NoProviding 18 mm cement plaster ( External ) Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR 2023-24 Ballari Circle Item No.8.9, Page No.42 Vol 2) Sqm404.25404.2577.32FalseNoneNoneFalseNoneFalse31256.610
3438952121980NonePWD SR 2023-24 Item No. 9.23, Page No.63 Vol 2Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent. (PWD SR 2023-24 Item No. 9.23, Page No.63 Vol 2)Sqm2589.32589.365.71FalseNoneNoneFalseNoneFalse170142.9030
3438953121980NoneSR 2023-24 Ballari Circle Item No.8.51, Page No.50Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (SR 2023-24 Ballari Circle Item No.8.51, Page No.50 Vol 2)Sqm105.0105.028.19FalseNoneNoneFalseNoneFalse2959.950
3438954121980NoneSR 2023-24 Ballari Circle Item No.8.54.2, Page No.Internal Wall painting with premium acrylic emulsion paint Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. (SR 2023-24 Ballari Circle Item No.8.54.2, Page No.50 Vol 2)Sqm115.5115.528.19FalseNoneNoneFalseNoneFalse3255.9450
3438955121980NoneSR 2023-24 Ballari Circle Item No.8.27, Page No.45Applying one coat of water thinnable cement primer Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (SR 2023-24 Ballari Circle Item No.8.27, Page No.45 Vol 2)Sqm55.6555.65105.53FalseNoneNoneFalseNoneFalse5872.74450
3438956121980NoneSR 2023-24 Ballari Circle Item No.8.28, Page No.45External Painting with water proofing cement paint ( External ) Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (SR 2023-24 Ballari Circle Item No.8.28, Page No.45 Vol 2)Sqm93.4593.4577.34FalseNoneNoneFalseNoneFalse7227.4230
3438957121980NonePWD SR 2023-24 Item No.11.28, Page No.85 vol 2P/F Stainless steel railing Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (PWD SR 2023-24 Item No.11.28, Page No.85 vol 2)Sqm593.25593.25193.5FalseNoneNoneFalseNoneFalse114793.8750
17199854470001NoneNoneBuildingsFIRST FLOOR ESTIMATION5448880.95
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3438958121981NoneCSR 2023-24 , I No : 2.5.2 , Page No : 16 , Vol 1P/ L RCC works M25 for Super structures Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Cum7253.587253.5812.74FalseNoneNoneFalseNoneFalse92410.60920
3438959121981NoneFormwork 70 percentPercentage Additionalities for Formwork, Centering & Scaffolding ( SR 2023-24 , Addendum I , Page No : 111 , Vol 1 . ) Percentage on finished rate of concrete per m3 Cum5077.515077.5112.74FalseNoneNoneFalseNoneFalse64687.47740
3438960121981NoneCSR 2023-24 , I No : 2.5.2 , Page No : 16 , Vol 1P/ L RCC works M25 for Super structures Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7253.587253.586.11FalseNoneNoneFalseNoneFalse44319.37380
3438961121981NoneFormwork add 60 percentPercentage Additionalities for Formwork, Centering & Scaffolding ( SR 2023-24 , Addendum I , Page No : 111 , Vol 1 . ) Percentage on finished rate of concrete per m3 Cum5077.515077.516.11FalseNoneNoneFalseNoneFalse31023.58610
3438962121981NoneCSR 2023-24 , I No : 2.5.2 , Page No : 16 , Vol 1P/ L RCC works M25 for Super structures Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ( CSR 2023-24 , I No : 2.5.2 , Page No : 16 , Vol 1 )Cum7253.587253.5818.8FalseNoneNoneFalseNoneFalse136367.3040
3438963121981NoneFormwork add for 60 percentPercentage Additionalities for Formwork, Centering & Scaffolding ( SR 2023-24 , Addendum I , Page No : 111 , Vol 1 . ) Percentage on finished rate of concrete per m3 Cum4352.154352.1518.8FalseNoneNoneFalseNoneFalse81820.420
3438964121981NoneCSR 2023-24 , I No : 2.5.2 , Page No : 16 , Vol 1P/ L RCC works M25 for Super structures Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7253.587253.5852.67FalseNoneNoneFalseNoneFalse382046.05860
3438965121981NoneFormwork Add 50 percentPercentage Addcumitionalities for Formwork, Centering & Scaffolding ( SR 2023-24 , Addendum I , Page No : 111 , Vol 1 . ) Percentage on finished rate of concrete per m3Cum3626.583626.5852.67FalseNoneNoneFalseNoneFalse191011.96860
3438966121981NoneCSR 2023-24 , I No : 2.5.2 , Page No : 16 , Vol 1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7253.587253.583.22FalseNoneNoneFalseNoneFalse23356.52760
3438967121981NoneFormwork add 45 PercentPercentage Additionalities for Formwork, Centering & Scaffolding ( SR 2023-24 , Addendum I , Page No : 111 , Vol 1 . ) Percentage on finished rate of concrete per m3 Cum3264.113264.113.22FalseNoneNoneFalseNoneFalse10510.43420
3438968121981NoneCSR 2023-24 , I No : 2.5.2 , Page No : 16 , Vol 1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7253.587253.583.22FalseNoneNoneFalseNoneFalse23356.52760
3438969121981NoneFormwork add for 50 percentPercentage Additionalities for Formwork, Centering & Scaffolding ( SR 2023-24 , Addendum I , Page No : 111 , Vol 1 . ) Percentage on finished rate of concrete per m3 Cum3626.793626.793.22FalseNoneNoneFalseNoneFalse11678.26380
3438970121981NoneCSR 2023-24 , I No : 2.1.4 , Page No : 15 , Vol 1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the\ work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates CSR 2023-24 , I No : 2.1.4 , Page No : 15 , Vol 1Cum6590.026590.023.76FalseNoneNoneFalseNoneFalse24778.47520
3438971121981NoneCSR 2023-24 , I No : 2.11 a, Page No : 18 , Vol 1P/F of TMT Bars Fe-550D Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification, a. Buildingst94824.4294824.4213.03FalseNoneNoneFalseNoneFalse1235562.19260
3438972121981NoneCSR 2023-24, Vol-2, SL.No. 6.2, Pg. No. 13Providing Brick work with common burnt clay Non Modular bricks Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8456.688456.68106.86FalseNoneNoneFalseNoneFalse903680.82480
3438973121981NoneCSR 2023-24, Vol-2, SL.No. 6.13, Pg. No. 14Providing Half brick masonry Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (CSR 2023-24, Vol-2, SL.No. 6.13, Pg. No. 14) Cum1034.561034.5668.77FalseNoneNoneFalseNoneFalse71146.69120
3438974121981NoneCSR 23-24 I No.12.13.2, Page No.100 Vol 2Providing Red Salwood frames Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. Sqm104580.0104580.00.9FalseNoneNoneFalseNoneFalse94122.00
3438975121981NoneCSR 2023-24 I No.12.57.1., Page No.105 vol 2Providing and fixing flush door shutter Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick Both side teak m4285.584285.5825.08FalseNoneNoneFalseNoneFalse107482.34640
3438976121981NoneCSR 2023-24 I No.12.93.1 Page No.111 Vol 2Providing & fixing factory made single Extruded Wood Polymer Composite (WPC) Solid door Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mm m744.12744.1236.0FalseNoneNoneFalseNoneFalse26788.320
3438977121981NoneCSR 2023-24 I No.12.94.1., Page No.112 Vol 2Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thickness Sqm3694.13694.111.34FalseNoneNoneFalseNoneFalse41891.0940
3438978121981NoneCSR 2023-24 I No.12.88, Page No.110 Vol 2Providing & fixing of 2-track x 2-panel sliding windows Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having a overall size of 60mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2-2.5 mm. Maximum possible size 1819mm x 1819mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm5713.45713.446.5FalseNoneNoneFalseNoneFalse265673.10
3438979121981NoneCSR 2023-24 I No.12.85, Page No.109 Vol 2Providing & fixing of louvered ventilator Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sqm6062.146062.1410.05FalseNoneNoneFalseNoneFalse60924.5070
3438980121981NoneCSR 2023-24 No.11.34B, Page No.85 Vol 2Providing and fixing M.S. grills Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. Kgs193.98193.98976.5FalseNoneNoneFalseNoneFalse189421.470
3438981121981NoneCSR 2023-24 I No.8.6.1, Page No.42 Vol 2Providing 12 mm cement plaster ( Internal ) Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerin- charge. Sqm342.38342.38815.12FalseNoneNoneFalseNoneFalse279080.78560
3438982121981NoneCSR 2023-24 I No.8.9, Page No.42 Vol 2Providing 18 mm cement plaster ( External ) Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm408.1408.1256.08FalseNoneNoneFalseNoneFalse104506.2480
3438983121981NoneCSR 2023-24 I No. 9.23, Page No.63 Vol 2Providing and laying Polished Granite stone flooring Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent. Sqm2613.962613.9672.57FalseNoneNoneFalseNoneFalse189695.07720
3438984121981NoneCSR 2023-24 Item No.9.12.2, Page No.60 Vol 2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mmSqm1213.71213.7245.19FalseNoneNoneFalseNoneFalse297587.1030
3438985121981NoneCSR 2023-24 I No.9.11, Page No.60 Vol 2P/L Ceramic glazed floor tiles Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.Sqm942.34942.3438.09FalseNoneNoneFalseNoneFalse35893.73060
3438986121981NoneCSR 2023-24 Item No.10.14, Page No.71 Vol 2Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg/m2, including pointing in white cement mixed with pigment of matching shade complete. (CSR 2023-24 Item No.10.14, Page No.71 Vol 2)Sqm1172.361172.3651.12FalseNoneNoneFalseNoneFalse59931.04320
3438987121981NoneCSR 2023-24 Item No.8.51, Page No.50 Vol 2Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (CSR 2023-24 Item No.8.51, Page No.50 Vol 2)Sqm106.0106.0815.09FalseNoneNoneFalseNoneFalse86399.540
3438988121981NoneCSR 2023-24 I No.8.54.2, Page No.50 Vol 2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.Sqm116.6116.6815.09FalseNoneNoneFalseNoneFalse95039.4940
3438989121981NoneCSR 2023-24 I No.8.27, Page No.45 Vol 2Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm56.1856.181071.16FalseNoneNoneFalseNoneFalse60177.76880
3438990121981NoneCSR 2023-24 Item No.8.28, Page No.45 Vol 2Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (CSR 2023-24 Item No.8.28, Page No.45 Vol 2)Sqm94.3494.34256.07FalseNoneNoneFalseNoneFalse24157.64380
3438991121981NoneCSR 2023-24 Item No.8.41, Page No.48 vol 2Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (CSR 2023-24 Item No.8.41, Page No.48 vol 2)Sqm177.02177.0246.5FalseNoneNoneFalseNoneFalse8231.430
3438992121981NoneCSR 2023-24, SL No 8.34.1, VOL-2, P.No .47Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (CSR 2023-24, SL No 8.34.1, VOL-2, P.No .47)Sqm56.1856.1825.08FalseNoneNoneFalseNoneFalse1408.99440
3438993121981NoneCSR 2023-24, Vol-2, Page No. 26. SL.No. 7.38Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.(CSR 2023-24, Vol-2, Page No. 26. SL.No. 7.38)Sqm602.08602.0820.64FalseNoneNoneFalseNoneFalse12426.93120
3438994121981NoneCSR 2023-24, Vol-2, Page No. 82. SL.No. 11.16.2Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (CSR 2023-24, Vol-2, Page No. 82. SL.No. 11.16.2)Kgs155.82155.8230.96FalseNoneNoneFalseNoneFalse4824.18720
3438995121981NoneCSR 2023-24 Item No.11.28, Page No.85 vol 2Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (CSR 2023-24 Item No.11.28, Page No.85 vol 2)Kg598.9598.9126.0FalseNoneNoneFalseNoneFalse75461.40
17199854470000NoneNoneBuildingsElectrical estimate809663.31
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3438996121982NonePWD Ele SR 2023-24, Item No 1.2.1 Page No-02 Vol-6Concealed Conduit System Supplying heavy gauge PVC conduit pipe 19/20mm dia 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessaryMtr69.369.3320.0FalseNoneNoneFalseNoneFalse22176.00
3438997121982NonePWD Ele SR 23-24, Item No 1.2.2 Page No2of105 V-6Concealed Conduit System Supplying heavy gauge PVC conduit pipe 25mm dia 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary Mtr81.981.9180.0FalseNoneNoneFalseNoneFalse14742.00
3438998121982NonePWD Ele SR 2023-24, I No2.1.1 Page No-05of 105 V-6Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr from tapping point to out let via switchPoint299.25299.2543.0FalseNoneNoneFalseNoneFalse12867.750
3438999121982NoneCSR 23-24 Elec V-6 Cr-2 It No.2.1.2Pg.No. 5 of 105Medium point above 3Mtr upto 6Mtr from tapping point to out let via switchEach413.7413.742.0FalseNoneNoneFalseNoneFalse17375.40
3439000121982NoneCSR 23-24 Elec V-6 C-2 It No.2.2.3 P.No. 5 of 105Long point above 6Mtr upto 10Mtr from tapping point to out let via switch Point582.75582.7545.0FalseNoneNoneFalseNoneFalse26223.750
3439001121982NoneCSR 23-24 Elec V-6 Cr-2 It No.2.3.1 P.No. 5 of 105Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:2010 1 sqmm. Mtr19.9519.95510.0FalseNoneNoneFalseNoneFalse10174.50
3439002121982NoneCSR 23-24 Elec V-6 Cr-2 It No.2.3.2 P.No. 5 of 105Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:2010 1.5sqmm. Each27.327.3920.0FalseNoneNoneFalseNoneFalse25116.00
3439003121982NoneCSR 23-24 Elec V-6 Cr-2 It No.2.3.3 P.No. 5 of 105Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:2010 2.5sqmm. Mtr44.144.1460.0FalseNoneNoneFalseNoneFalse20286.00
3439004121982NoneCSR 23-24 Elec V-6 Cr-2 It No.2.3.4 P.No. 5 of 105Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:2010 4sqmm.Mtr66.1566.15180.0FalseNoneNoneFalseNoneFalse11907.00
3439005121982NoneCSR 23-24 Elec V-6 Cr-2 It No.3.6.1P.No. 9 of 105Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps one way switch. Each107.1107.1220.0FalseNoneNoneFalseNoneFalse23562.00
3439006121982NoneCSR 23-24 Elec V-6 Cr-2 It No.3.6.3 P.No. 9 of 105Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps Three Way Socket Each179.55179.5555.0FalseNoneNoneFalseNoneFalse9875.250
3439007121982NoneCSR 23-24 Elec V-6 Cr-2 It No.3.6.5 Pg.No. 9 of 10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 400w Dimmer Each289.8289.830.0FalseNoneNoneFalseNoneFalse8694.00
3439008121982NoneCSR 23-24 Elec V-6 Cr-2 It No.3.6.7 P.No. 9 of 105Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 16Amps one way switch.Each189.0189.06.0FalseNoneNoneFalseNoneFalse1134.00
3439009121982NoneCSR 23-24 Elec V-6 Cr-2 It No.3.6.10 Pg.No. 9 of 1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 6/16Amps Universal SocketEach247.8247.86.0FalseNoneNoneFalseNoneFalse1486.80
3439010121982NoneCSR 23-24 Elec V-6 Cr-2 It No.3.14.5 P.No. 10 of 1Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board. 6Amps Bakelite Ceiling Rose No81.981.930.0FalseNoneNoneFalseNoneFalse2457.00
3439011121982NoneCSR 23-24 Elec V-6 Cr-2 It No.3.14.6 P.No. 10 of 1Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board. 6Amps Pendent Holder No74.5574.5514.0FalseNoneNoneFalseNoneFalse1043.70
3439012121982NoneCSR 23-24 Elec V-6 Cr-2 It No.3.14.7 P.No. 10 of 1Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board. 6Amps Batten Holder No77.777.793.0FalseNoneNoneFalseNoneFalse7226.10
3439013121982NoneCSR 23-24 Elec V-6 Cr-1 It No.1.13 P.No. 4 of 105Supplying And Fixing Metal Fan Box with Round Hook. No122.85122.8530.0FalseNoneNoneFalseNoneFalse3685.50
3439014121982NoneCSR 23-24 Elec V-6 C-1It No.1.5.1 P .No. 2 of 105Supplying and fixing PVC/metal conduit Deep junction box - 19/20mm deep junction box Each51.4551.4560.0FalseNoneNoneFalseNoneFalse3087.00
3439015121982NoneCSR 23-24 Elec V-6 Cr-1 It No-1.5.2 P.No-3 of 105Supplying and fixing PVC/metal conduit Deep junction box - 25mm Each58.858.840.0FalseNoneNoneFalseNoneFalse2352.00
3439016121982NoneCSR 23-24 Elec V-6 Cr-2 It No.3.6.12 P No. 9 of 10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 RJ45/IO Outlet Cat-6 Each353.85353.858.0FalseNoneNoneFalseNoneFalse2830.80
3439017121982NoneCSR 23-24 Elec V-6 Cr-8 It No.8.1 P .No.36 of 105Supplying and drawing UTP-CAT 6E LAN cable. Mtr39.939.990.0FalseNoneNoneFalseNoneFalse3591.00
3439018121982NoneCSR 23-24 Elec V-6 Cr-8 It No.8.4.4 P.No.36 of 105Supplying & Fixing of switch mounting rack with power manager & Cable manager. 12U with 450mm depth Each9276.759276.751.0FalseNoneNoneFalseNoneFalse9276.750
3439019121982NoneCSR 23-24 Elec Vol-6 Cr-8 It No.8.9.3PNo.36 of 105Supplying fixing of Network Switches 10 Port Gigabyte (manageable) Each21210.021210.01.0FalseNoneNoneFalseNoneFalse21210.00
3439020121982NoneCSR 23-24 Elec V-6 Cr-8 It No.8.10.2 P.No.37Supplying & fixing of I/O socket with back box Double I/o Each577.5577.54.0FalseNoneNoneFalseNoneFalse2310.00
3439021121982NoneCSR 23-24 Elec V-6 Cr-8 It No.8.11.2 P.No.37 of 10Supplying & Fixing of 2Mtrs Cat 6 Patch Cable Each269.85269.854.0FalseNoneNoneFalseNoneFalse1079.40
3439022121982NoneCSR 23-24 Elec V-6 Cr-1 It No.1.8.1 P.No.3 of 105Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, screws at an interval of 300mm …. etc. as required. 20mm Mtr29.429.450.0FalseNoneNoneFalseNoneFalse1470.00
3439023121982NoneCSR 23-24 Elec V-6 Cr-9 It No.9.2.5 P.No.38 of 105Supplying, erecting, testing & commissioning of 5KVA OFFLINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with all accessories complete and Excluding batteries and wiring complete. Each41892.941892.91.0FalseNoneNoneFalseNoneFalse41892.90
3439024121982NoneCSR 23-24 Elec V-6 Cr-9 It No.9.4.6 PNo. 38 of 105Supplying, installation, testing & commissioning of 12V DC,AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 150 AH capacity Each16689.7516689.754.0FalseNoneNoneFalseNoneFalse66759.00
3439025121982NoneCSR 23-24 Elec V-6 Cr-3 It No.3.4.3 PNo.8 of 105Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 4-5Way Each185.85185.852.0FalseNoneNoneFalseNoneFalse371.70
3439026121982NoneCSR 23-24 Elec V-6 Cr-3 It No.3.4.4 PNo.8 of 105Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 6Way Each231.0231.011.0FalseNoneNoneFalseNoneFalse2541.00
3439027121982NoneCSR 23-24 Elec V-6 Cr-3 It No.3.4.5 PNo.8 of 105Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 8Way Each274.05274.056.0FalseNoneNoneFalseNoneFalse1644.30
3439028121982NoneCSR 23-24 Elec V-6 Cr-3 It No.3.4.6 PNo.8 of 105Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 10-12Way Each334.95334.9510.0FalseNoneNoneFalseNoneFalse3349.50
3439029121982NoneCSR 23-24 Elec V-6 Cr-3 It No.3.4.8 PNo.8 of 105Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 18Way Each425.25425.258.0FalseNoneNoneFalseNoneFalse3402.00
3439030121982NoneCSR 23-24 Elec V-6 Cr-3 It No.3.5.3 PNo.8 of 105Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4Module Each183.75183.752.0FalseNoneNoneFalseNoneFalse367.50
3439031121982NoneCSR 23-24 Elec V-6 Cr-3 It No.3.5.4 PNo.8 of 105Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6Module Each245.7245.711.0FalseNoneNoneFalseNoneFalse2702.70
3439032121982NoneCSR 23-24 Elec V-6 Cr-3 It No.3.5.5 PNo.8 of 105Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8Module Each298.2298.26.0FalseNoneNoneFalseNoneFalse1789.20
3439033121982NoneCSR 23-24 Elec V-6 Cr-3 It No.3.5.6 PNo.8 of 105Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12Module Each361.2361.210.0FalseNoneNoneFalseNoneFalse3612.00
3439034121982NoneCSR 23-24 Elec V-6 Cr-3 It No.3.5.8 PNo.8 of 105Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 18Module Each479.85479.858.0FalseNoneNoneFalseNoneFalse3838.80
3439035121982NoneCSR 23-24 Elec V-6 Cr-11 ItNo.11.3.2PNo.42 of 105Supplying of LED Light fighting 1 x 4 feet PVC Batten with integrated LED tube 20/22W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.Each724.5724.551.0FalseNoneNoneFalseNoneFalse36949.50
3439036121982NoneCSR 23-24 Elec V-6 Cr-13 ItNo.13.7.1PNo.56 of 105Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders Each128.1128.151.0FalseNoneNoneFalseNoneFalse6533.10
3439037121982NoneCSR 23-24 Elec V-6 Cr-6 ItNo.6.3.1PNo.30 of 105Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model Each3133.23133.221.0FalseNoneNoneFalseNoneFalse65797.20
3439038121982NoneCSR 23-24 Elec V-6 Cr-13 ItNo.13.10PNo.57 of 105Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. Each179.55179.5521.0FalseNoneNoneFalseNoneFalse3770.550
3439039121982NoneCSR 23-24 Elec V-6 Cr-6 ItNo.6.1PNo.30 of 105Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. Each1566.61566.66.0FalseNoneNoneFalseNoneFalse9399.60
3439040121982NoneCSR 23-24 Elec V-6 Cr-13 ItNo.13.14PNo.57 of 105Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 amps. ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire. Each516.6516.66.0FalseNoneNoneFalseNoneFalse3099.60
3439041121982NoneCSR 23-24 Elec V-6 Cr-11 ItNo.11.11.3PNo.47 of 105Supplying & fixing of retrofit type LED bulb 7W 6500K with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70percent. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5percent of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20percent, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.Each156.45156.456.0FalseNoneNoneFalseNoneFalse938.70
3439042121982NoneCSR 23-24 Elec V-6 Cr-11 ItNo.11.14.2PNo.47 of 105Supplying and fixing of slim box fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Flouresent Tube. 1 x 4' Tube light fitting. Each379.05379.0510.0FalseNoneNoneFalseNoneFalse3790.50
3439043121982NoneCSR 23-24 Elec V-6 Cr-5 ItNo.5.18.1PNo.17 of 105Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32Amps SP Each435.75435.7516.0FalseNoneNoneFalseNoneFalse6972.00
3439044121982NoneCSR 23-24 Elec V-6 Cr-5 ItNo.5.18.8PNo.17 of 105Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40Amps TPN Each3196.23196.28.0FalseNoneNoneFalseNoneFalse25569.60
3439045121982NoneCSR 23-24 Elec V-6 Cr-5 ItNo.5.19.8PNo.18 of 105Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. II - Double Door 8Way SP &N Each1946.71946.72.0FalseNoneNoneFalseNoneFalse3893.40
3439046121982NoneCSR 23-24 Elec V-6 Cr-5 ItNo.5.19.9PNo.18 of 105Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.II - Double Door 12Way SP &N Each2445.452445.452.0FalseNoneNoneFalseNoneFalse4890.90
3439047121982NoneCSR 23-24 Elec V-6 Cr-11 ItNo.11.8.4PNo.46 of 105Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia /Lumileds/Osram make LED Source.LED Streetlight 90watts Each9303.09303.03.0FalseNoneNoneFalseNoneFalse27909.00
3439048121982NoneCSR 23-24 Elec V-6 Cr-13 ItNo.13.2.3PNo.46 of 105Supplying and Fixing 40mm dia class A GI pipe bracket up to 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires. Each1551.91551.93.0FalseNoneNoneFalseNoneFalse4655.70
3439049121982NoneCSR 23-24 Elec V-6 Cr-13 ItNo.13.5PNo.56 of 105Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. Each170.1170.13.0FalseNoneNoneFalseNoneFalse510.30
3439050121982NoneCSR 23-24 Elec V-6 Cr-5 ItNo.5.42.2PNo.20 of 105Fabricating supplying and mounting MS box made out 16SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., Sq CM0.450.45150000.0FalseNoneNoneFalseNoneFalse67500.00
3439051121982NoneCSR 23-24 Elec V-6 Cr-5 ItNo.5.41.2PNo.20 of 105Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 50x50x6mm Mtr414.75414.7510.0FalseNoneNoneFalseNoneFalse4147.50
3439052121982NoneCSR 23-24 Elec V-6 Cr-5 ItNo.5.40.1PNo.20 of 105Supplying 100Amps 4x30x6mm Aluminum Strips rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. Mtr2588.252588.252.0FalseNoneNoneFalseNoneFalse5176.50
3439053121982NoneCSR 23-24 Elec V-6 Cr-5 ItNo.5.38.1PNo.19 of 105Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C. Each540.75540.753.0FalseNoneNoneFalseNoneFalse1622.250
3439054121982NoneCSR 23-24 Elec V-6 Cr-5 ItNo.5.21PNo.18 of 105Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. Each9717.759717.751.0FalseNoneNoneFalseNoneFalse9717.750
3439055121982NoneCSR 23-24 Elec V-6 Cr-5 ItNo.5.29PNo.19 of 105Supplying, fixing and wiring 3 Phase Digital Ammeter /Voltmeter. Each1496.251496.251.0FalseNoneNoneFalseNoneFalse1496.250
3439056121982NoneCSR 23-24 Elec V-6 Cr-5 ItNo.5.31PNo.19 of 105Supplying and fixing Trivector Meter suitable for operation LT operation and -CT operated meter in polycarbonate body in class 0.5 accuracy as per IS 14697 and completely wired. Each4609.54609.51.0FalseNoneNoneFalseNoneFalse4609.50
3439057121982NoneCSR 23-24 Elec V-6 Cr-5 ItNo.5.32PNo.19 of 105Supplying and fixing digital frequency meter with latest micro controller technology, ultra bright 4 digit LED display, from 30-500V AC and optional or relay output for high/low frequency and wiring complete. Each1023.751023.751.0FalseNoneNoneFalseNoneFalse1023.750
3439058121982NoneCSR 23-24 Elec V-6 Cr-5 ItNo.5.33PNo.19 of 105Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy. Each9780.759780.751.0FalseNoneNoneFalseNoneFalse9780.750
3439059121982NoneCSR 23-24 Elec V-6 Cr-5 ItNo.5.34PNo.19 of 105Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound. Each590.1590.13.0FalseNoneNoneFalseNoneFalse1770.30
3439060121982NoneCSR 23-24 Elec V-6 Cr-5 ItNo.5.35PNo.19 of 105Supplying, fixing and wiring electronic 10 to 40 Amps three phase 4 wire class-1 Accuracy Energy Meter. Each5990.255990.251.0FalseNoneNoneFalseNoneFalse5990.250
3439061121982NoneEscom SR 23-24 Sl.No.205 It.No.32.09PNo.13 of 811.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 35 Sqmm, 3.5 Core, (14 GI Strips - 4 x 0.8 mm)" Km161765.1161765.10.2FalseNoneNoneFalseNoneFalse32353.020
3439062121982NoneEscom SR 2023-24 Sl.No.472 It.No.60.04P.No.70of 81Aluminium End Terminal (Lug) No4.24.28.0FalseNoneNoneFalseNoneFalse33.60
3439063121982NoneEscom SR 2023-24 It.No.29.02P.No.63 of 81Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. In Ordinary Soil Cum273.0273.075.0FalseNoneNoneFalseNoneFalse20475.00
3439064121982NoneEscom SR 2023-24Sl.No.175It.No.21.06PNo.52 of 81Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 to 95 Sqmm Km32695.9532695.950.2FalseNoneNoneFalseNoneFalse6539.190
3439065121982NoneEscom SR 2023-24 Sl.No.46 It.No.48.06 PNo.38 of 81GI Pipe B - Class as per IS-1239 GI Pipe - 63 mm Dia Mtr368.55368.554.0FalseNoneNoneFalseNoneFalse1474.20
3439066121982NoneCSR 23-24 Elec Vol-6Cr-5 It No.5.15.11P.No.17of105Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics) FOUR POLE 160Amps 25kA. Each14119.3514119.351.0FalseNoneNoneFalseNoneFalse14119.350
3439067121982NoneCSR 23-24 Elec Vol-6Cr-5 It No.5.7.41P.No.14of105Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 100Amps Each725.55725.554.0FalseNoneNoneFalseNoneFalse2902.20
3439068121982NoneCSR 23-24 Elec Vol-6Cr-5 It No.5.7.41P.No.14of105Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia No3685.53685.54.0FalseNoneNoneFalseNoneFalse14742.00
17199854470000NoneNoneBuildingsWater Supply & Sanitary275724.53
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3439069121983NoneCSR For 2023-24 Item No 14.44 Page No-138Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. ( SR 2023-24 / Item No : 14.44 , Page No : 138 Vol 2) Each11785.211785.22.0FalseNoneNoneFalseNoneFalse23570.40
3439070121983NoneCSR For 2023-24 Item No 14.1.1 Page No-131P/F Indian type W.C. pan Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests ( SR 2023-24 / Item No : 14.1.1 , Page No : 131 Vol 2) Each5128.25128.24.0FalseNoneNoneFalseNoneFalse20512.80
3439071121983NoneCSR For 2023-24 Item No 14.25.1 Page No 131P/F Flat back wash basin Providing and fixing white vitreous china wash basin including making all connections but including the cost of fittings Flat back wash basin of size 630x450 mm. ( SR 2023-24 / Item No : 14.25.1 , Page No : 135 Vol 2) Each1035.31035.36.0FalseNoneNoneFalseNoneFalse6211.80
3439072121983NoneCSR For 2023-24 Item No 13.27.2 Page No 121P/F Unplasticised P.V.C. connection pipe Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 15 mm nominal bore with 450 mm length ( SR 2023-24/ Item No : 13.27.2 , Page No : 121 Vol 2) Each121.8121.86.0FalseNoneNoneFalseNoneFalse730.80
3439073121983NoneCSR For 2023-24 Item No 14.28.1.1 Page No 136P/F Semi Rigid P.V.C. waste pipe Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.32 mm dia ( SR 2023-24 / Item No : 14.28.1.1 , Page No : 136 Vol 2) Each79.879.86.0FalseNoneNoneFalseNoneFalse478.80
3439074121983NoneCSR For 2023-24 Item No 13.14 Page No 119P/F Long body bib cock Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 g. ( SR 2023-24 / Item No : 13.14 , Page No : 119 Vol 2) Nos888.3888.318.0FalseNoneNoneFalseNoneFalse15989.40
3439075121983NoneCSR For 2023-24 Item No 13.16 Page No 119P/F C.P. brass angle valve Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 ( SR 2023-24 / Item No : 13.16 , Page No : 119 Vol 2) Nos651.0651.04.0FalseNoneNoneFalseNoneFalse2604.00
3439076121983NoneCSR For 2023-24 Item No 13.22.2 Page No 120P/F Grating Rectangular type with openable circular lid Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid ( SR 2023-24/ Item No : 13.22.2 , Page No : 120 Vol 2) Nos212.1212.14.0FalseNoneNoneFalseNoneFalse848.40
3439077121983NoneCSR For 2023-24 Item No 13.6.1.1 Page No 117P/F Non- return valve Providing and fixing gun metal non- return valve of approved quality (screwed end) : 25 mm nominal bore Horizontal (SR 2023-24 / Item No : 13.6.1.1 , Page No : 117 Vol 2) Nos651.0651.04.0FalseNoneNoneFalseNoneFalse2604.00
3439078121983NoneCSR For 2023-24 Item No 13.5.3 Page No 117P/F Ball valve (brass) Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore ( SR 2023-24 / Item No : 13.5.3 , Page No : 117 Vol 2) Nos348.6348.64.0FalseNoneNoneFalseNoneFalse1394.40
3439079121983NoneCSR For 2023-24 Item No 14.38 Page No 137P/F Soap container Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 g. (SR 2023-24 / Item No : 14.38 , Page No : 137 Vol 2) Each152.25152.256.0FalseNoneNoneFalseNoneFalse913.50
3439080121983NoneCSR For 2023-24 Item No 13.33.6 Page No 123Chorinated poly vinyl Chloride (CPVC) pipes Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50 mm nominal dia Pipes (SR 2023-24 / Item No : 13.33.6 , Page No : 123 Vol 2) m757.05757.0585.0FalseNoneNoneFalseNoneFalse64349.250
3439081121983NoneCSR For 2023-24 Item No 13.23.3 Page No 122Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. (SR 2023-24 / Item No : 13.32.3 , Page No : 122 Vol 2) m500.85500.85100.0FalseNoneNoneFalseNoneFalse50085.00
3439082121983NoneCSR For 2023-24 Item No 13.34 Page No 123Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. ( SR 2023-24 / Item No : 13.34 , Page No : 123 Vol 2) Ltr9.459.452000.0FalseNoneNoneFalseNoneFalse18900.00
3439083121983NoneCSR For 2023-24 Item No 1.15.2 Page No 09Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. Depth exceeding 1.5 m, but not exceeding 3 m ( SR 2023-24 / Item No : 1.15.2 , Page No : 9 Vol 1 ) Cum446.25446.2519.87FalseNoneNoneFalseNoneFalse8866.98750
3439084121983NoneCSR For 2023-24 Item No 16.9 Page No 191Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. ( SR 2023-24 / Item No : 16.9 , Page No : 191 Vol 5) Each5726.75726.72.0FalseNoneNoneFalseNoneFalse11453.40
3439085121983NoneCSR For 2023-24 Item No 7.3 Page No 85Providing and fixing MS inspection door of size 60 cms x 60 cms, including MS frame made of 50x50x6mm angle, shutters made of 3mm thick MS sheets, with hinges, locking arrangements at top etc. including painting with anticorrosive approved paint etc. complete including all lead and lifts etc. (PWD SR 2023-24 Ballari Circle Item No.7.3 Page No.85 Vol 5) Each2247.02247.02.0FalseNoneNoneFalseNoneFalse4494.00
3439086121983NoneCSR For 2023-24 Item No 10.2.2 Page No 114Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for: Pipes of SN4, 110mm dia. ( SR 2023-24 / Item No : 10.2.2 , Page No : 114 Vol 5) m302.4302.4120.0FalseNoneNoneFalseNoneFalse36288.00
3439087121983NoneCSR For 2023-24 Item No 1.9 Page No 34Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ( SR 2023-24 , Item No : 1.9 , Page No : 34 , Vol 1 ) Cum279.3279.319.44FalseNoneNoneFalseNoneFalse5429.5920
17199854470001NoneNoneBuildingsUnder Ground Water Tank(Sump)396131.03
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3439088121984NoneCSR For 2023-24 Item No 1.15.3 Page No 09Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Depth exceeding 3m, but not exceeding 4.5m ( SR 2023-24 / Item No : 1.15.3 , Page No : 9 Vol 1 ) Cum486.15486.1579.88FalseNoneNoneFalseNoneFalse38833.6620
3439089121984NoneCSR For 2023-24 Item No 2.1.3 Page No 15Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ( SR 2023-24 / Item No : 2.1.3 , Page No : 15 Vol 1) Cum6288.456288.452.66FalseNoneNoneFalseNoneFalse16727.2770
3439090121984NoneCSR For 2023-24 Item No 2.4.3 Page No 16Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ( SR 2023-24 , Item No : 2.4.3 , Page No : 16 , Vol 1 ) Cum6652.86652.84.72FalseNoneNoneFalseNoneFalse31401.2160
3439091121984NoneCSR For 2023-24 Item No 2.4.3 Page No 16Percentage Additionalities for Formwork, Centering & Scaffolding ( SR 2023-24 , Addendum I , Page No : 111 , Vol 1 . ) Percentage on finished rate of concrete per m3 50%Cum3326.43326.44.72FalseNoneNoneFalseNoneFalse15700.6080
3439092121984NoneCSR For 2023-24 Item No 2.4.3 Page No 16Bottom Raft Cum6652.86652.84.72FalseNoneNoneFalseNoneFalse31401.2160
3439093121984NoneCSR For 2023-24 Item No 2.4.3 Page No 16Percentage Additionalities for Formwork, Centering & Scaffolding ( SR 2023-24 , Addendum I , Page No : 111 , Vol 1 . ) Percentage on finished rate of concrete per m3 50%Cum3326.43326.44.72FalseNoneNoneFalseNoneFalse15700.6080
3439094121984NoneCSR For 2023-24 Item No2.4.3 Page No 16Side walls Cum6652.86652.85.88FalseNoneNoneFalseNoneFalse39118.4640
3439095121984NoneCSR For 2023-24 Item No 2.4.3 Page No 16Percentage Additionalities for Formwork, Centering & Scaffolding ( SR 2023-24 , Addendum I , Page No : 111 , Vol 1 . ) Percentage on finished rate of concrete per m3 10%Cum665.28665.285.88FalseNoneNoneFalseNoneFalse3911.84640
3439096121984NoneCSR For 2023-24 Item No 2.11A Page No 18Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification, a. Buildings ( SR 2023-24 , Item No : 2.11 a, Page No : 18 , Vol 1 ) Kgs93929.8593929.851.46FalseNoneNoneFalseNoneFalse137137.5810
3439097121984NoneCSR For 2023-24 Item No 1.9 Page No 34Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (COMMON SR 2023-24,Vol-1 SL.No. 1.9, P. No. 34) Cum279.3279.37.84FalseNoneNoneFalseNoneFalse2189.7120
3439098121984NoneCSR For 2023-24 Item No 6.32 Page No 17Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (PWD SR 2023-24, Item no.6.32, Page No.17 Vol 2) Cum1375.51375.57.84FalseNoneNoneFalseNoneFalse10783.920
3439099121984NoneCSR For 2023-24 Item No 8.9 Page No 42Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR 2023-24 Item No.8.9, Page No.42 Vol 2) Sqm404.25404.2586.44FalseNoneNoneFalseNoneFalse34943.370
3439100121984NoneCSR For 2023-24 Item No 7.3 Page No 85Providing and fixing MS inspection door of size 60 cms x 60 cms, including MS frame made of 50x50x6mm angle, shutters made of 3mm thick MS sheets, with hinges, locking arrangements at top etc. including painting with anticorrosive approved paint etc. complete including all lead and lifts etc. (PWD SR 2023-24 Ballari Circle Item No.7.3 Page No.85 Vol 5) Each2247.02247.02.0FalseNoneNoneFalseNoneFalse4494.00
3439101121984NoneCSR For 2023-24 Item No 7.1 Page No 85Providing and fixing MS ladder between landings, 45 cms wide using angle iron of specified sizes, 20mm MS bars at 25 cms. centre to centre, with necessary supports of same angle iron etc. as directed, including hand railing on both sides with 25mm dia. GI pipes with angle iron props at 2 mtrs. intervals and 0.5M heigh, including fixing in ground with CC 1:2:4 and two coats of anticorrosive bituminous paint etc. with all lead and lifts etc. complete with: MS angle of 65 x 65 x 8mm (PWD SR 2023-24 Ballari Circle Item No.7.1 Page No.85 Vol 5) m4595.854595.853.0FalseNoneNoneFalseNoneFalse13787.550
17199854470001NoneNoneBuildingsSeptic Tank283214.35
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3439102121985NoneCSR For 2023-24 Item No 1.15.3 Page No 09Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Depth exceeding 3m, but not exceeding 4.5m Cum486.15486.1567.37FalseNoneNoneFalseNoneFalse32751.92550
3439103121985NoneCSR For 2023-24 Item No 2.1.3 Page No 15Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates Cum6288.456288.453.31FalseNoneNoneFalseNoneFalse20814.76950
3439104121985NoneCSR For 2023-24 Item No 2.4.3 Page No 16Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Cum6652.86652.87.67FalseNoneNoneFalseNoneFalse51026.9760
3439105121985NoneCSR For 2023-24 Item No 2.4.3 Page No 16Percentage Additionalities for Formwork, Centering & Scaffolding ( SR 2023-24 , Addendum I , Page No : 111 , Vol 1 . ) Percentage on finished rate of concrete per m3 50%Cum3326.43326.47.67FalseNoneNoneFalseNoneFalse25513.4880
3439106121985NoneCSR For 2023-24 Item No 2.11a Page No 18Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification, a. Buildings Kgs93929.8593929.850.61FalseNoneNoneFalseNoneFalse57297.20850
3439107121985NoneCSR For 2023-24 Item No 5.4 Page No 09Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand Cum6708.456708.458.4FalseNoneNoneFalseNoneFalse56350.980
3439108121985NoneCSR For 2023-24 Item No 8.3.2 Page No 41Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge Sqm349.65349.6584.0FalseNoneNoneFalseNoneFalse29370.60
3439109121985NoneCSR For 2023-24 Item No 7.3 Page No 85Providing and fixing MS inspection door of size 60 cms x 60 cms, including MS frame made of 50x50x6mm angle, shutters made of 3mm thick MS sheets, with hinges, locking arrangements at top etc. including painting with anticorrosive approved paint etc. complete including all lead and lifts etc. Nos2247.02247.02.0FalseNoneNoneFalseNoneFalse4494.00
3439110121985NoneCSR For 2023-24 Item No 10.14.8 Page No 120Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges,handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.110mm(weight of pipe -1.894 kg) m466.2466.212.0FalseNoneNoneFalseNoneFalse5594.40
17199854470001NoneNoneBuildingsSoak Pit104868.64
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3439111121986NoneCSR For 2023-24 Item No 1.15.2 Page No 09Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Depth exceeding 1.5 m, but not exceeding 3 m Cum446.25446.2515.55FalseNoneNoneFalseNoneFalse6939.18750
3439112121986NoneCSR For 2023-24 Item No 2.1.3 Page No 15Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates Cum6288.456288.450.71FalseNoneNoneFalseNoneFalse4464.79950
3439113121986NoneCSR For 2023-24 Item No 5.4 Page No 09Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.453.87FalseNoneNoneFalseNoneFalse25961.70150
3439114121986NoneCSR For 2023-24 Item No 6.2 Page No 13Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Cum8376.98376.94.74FalseNoneNoneFalseNoneFalse39706.5060
3439115121986NoneCSR For 2023-24 Item No 2.5.1 Page No 16Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite /trap / basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Cum6961.56961.51.06FalseNoneNoneFalseNoneFalse7379.190
3439116121986NoneCSR For 2023-24 Item No 2.5.1 Page No 16Percentage Additionalities for Formwork, Centering & Scaffolding ( SR 2023-24 , Addendum I , Page No : 111 , Vol 1 . ) Percentage on finished rate of concrete per m3 50%Cum3480.753480.751.06FalseNoneNoneFalseNoneFalse3689.5950
3439117121986NoneCSR For 2023-24 Item No 2.11a Page No 18Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification, a. Buildings Kgs93929.8593929.850.08FalseNoneNoneFalseNoneFalse7514.3880
3439118121986NoneCSR For 2023-24 Item No 8.3.2 Page No 41Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge Sqm349.65349.6526.35FalseNoneNoneFalseNoneFalse9213.27750
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17199854480000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17199854480000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17199854480001NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17199854480000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17199854480000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17199921130000NoneNoneELIGIBILITYThe Tenderer shall obtain the workdone certificate in the prescribed format from the Competent Authority not below the rank of Executive Engineer (District Level Officer) and scan the Original Certificate and attach the scanned file to the Bid. The Original Certificate/Certificates shall be produced at the time of opening of technical Bids for physical verification.None
17199921170000NoneNoneELIGIBILITYFinancial Year will be reckoned as the period between first day of April and Thirty first day of March of succeeding year(both days inclusive).None
17199921220000NoneNoneELIGIBILITYThe Tenderer shall scan the Original Ownership Documents/ Lease/ Hire commitment Agreement for the Machinery and attach the scanned file to the Bid. The Original Documents shall be produced at the time of opening of technical Bids for physical verification.None
17199921280000NoneNoneELIGIBILITYThe tenderer shall note that the scanned Documents can also be uploaded in the tasks created under Document/Evidence Required from the BidderNone
17199921320000NoneNoneELIGIBILITYThe Employer reserves the right to Reject any or all Tenders without assigning any reason.None
17199921360000NoneNoneELIGIBILITYThe Department is not responsible for any delay in accessing KPP-PortalNone
17199921510000NoneNoneELIGIBILITYTenderer shall note that the Tenders of those found Eligible as mentioned in Clause 3 - Qualification of the Tenderer in Section 2 : Instructions to Tenderers (ITT), will only be considered for evaluation.None
17199921560000NoneNoneELIGIBILITYThe rates of all the items appeared in Bill of Quantities are inclusive of all leads and liftsNone
17199921630000NoneNoneELIGIBILITYAs per circular of Govt. of Karnataka Government Order No. PWD 107 CRM 2013, Bangalore, Dated: 20.02.2014, If the tenderer uploads the Bank Guarantee, but does not produce original at the time of technical scrutiny, such tenders will not be disqualified either in the technical bid stage or financial bid stage. But the qualified tenderer (L1) must submit the original copy of the BG at the time of agreement.None
17199921670000NoneNoneELIGIBILITYThe contractor shall bound to comply the prevailing rules and regulations with regard to the EPF rules and any modifications before and after execution of agreementNone
17199921720000NoneNoneELIGIBILITYAfter the award of the contract, the contractor has to furnish the details in respect of labour employed and the EPF details for this work in every RA bill.None
17199921780000NoneNoneELIGIBILITYThe Increse in GST shall not be paid in the extended period of contract for which the contractor alone is responsible for delay as determined by the authority while granting the extension of time.None
17199921830000NoneNoneELIGIBILITYThe bidder should mention the UDIN No on the turnover certificate, failing which bid is rejected.None
17199921880000NoneNoneELIGIBILITYIf the bidder uploaded the false document while participating in the tender, the bidder will be responsible and action will be initiated as per the tender clause.None
17199921930000NoneNoneELIGIBILITYThe star rates inrespect of specified materials ( Cement, Steel and Bitumen) shall be payable as per CIRCULAR NO.PWD 159 CRM 2009 Bangalore Dated 30.09.2010None
17199921970000NoneNoneELIGIBILITYFinancial turnover of previous years shall be given a weight of 10% per year to bring them to the price level of the 2024-25 in the Technical Qualification Criteria mentioned in the next section.None
17199922020000NoneNoneELIGIBILITYThe work should be completed in 11 (Eleven) Months ( including monsoon)None
17199922070000NoneNoneELIGIBILITYThe earnest money deposit shall be in two parts i.e.,Part (1) Rs.1,00,000 by e.payment and balance Part (2) Rs. Balance amount as specified in the KPP portal shall be in the form of Bank Guarantee in the prescribed format obtained from the Nationalized / Schedule Bank FDR or specified small savings instrument pledged to the Executive Engineer, Public Works Department Division, HOSAPETE payable at HOSAPETE before the prescribed date and time of opening of Technical Bid without failNone
17199922180000NoneNoneELIGIBILITYAny dispute or difference or claim arising out of, or in connection with, or relating to the present contract or the breach, termination or invalid thereof shall be referred and settled under the Arbitration centre Karnataka (Domastic and international Rules 2012,by one or more arbitratiors appointed in accordance with its rulesNone
17199922230000NoneNoneELIGIBILITYThe deffect liability period is one year (1Year)from the date of actual completion of work.None
17199922300000NoneNoneELIGIBILITY18%GST Will paid extra to the executed quantitesNone
17205095380000NoneNoneELIGIBILITYAll units of the items should be read as per approved SRNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneTo qualify for award of this contract, each Tenderer in his name should have in the last five years i.e.,2019-20, 2020-21 2021-22,2022-23 & 2023-24 b) Executed in any one year, the following minimum quantities of work: 1 Earth work /Embankment/Sub Grade/Shoulder 622.32 Cum 2.CC/PCC/RCC/DLC 298.08 Cum 3.Steel 27.46 Tonnes 4. SSM/BBM 224.73Cum 5. Flooring 337.24 Sqm 6. Plastaring1161.56 SqmPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneTo qualify for award of this contract, each Tenderer in his name should have in the last five years i.e.,2019-20, 2020-21 2021-22,2022-23 &2023-24 b) Satisfactorily completed, as prime contractor, at least one similar work such as Building Work of value not less than Rs.63.53LakhsPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneRegistration CertificateCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneTo qualify for award of this contract, each Tenderer in his name should have in the last five years i.e.2019-20, 2020-21 2021-22, 2022-23 &2023-24 a) Achieved in at least two financial years a minimum financial turnover (in all classes of civil engineering construction works only) of Rs.254.13LakhsFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneLiquid Assets and /or availability of credit facilities of no less than Rs.34.65lakhs (Credit Lines/letter of credit/ certificates from the banks for meeting the fund requirement etc.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Registration CertificateTrueTechnical Bid
Annual Turnover Certificate Not below the rank of Charterd Accountant,The bidder should mention the UDIN NoTrueTechnical Bid
Single Work Done Certificate Not Below the rank of Executive Engineer/Work indent should be mentionedTrueTechnical Bid
Quantity Wise Work Done Certificate/Work indent should be mentionedTrueTechnical Bid
Liquid AssetsTrueTechnical Bid
GST CERTIFICATETrueTechnical Bid
Principal Place of Business.TrueTechnical Bid
Tender Bid CapacityTrueTechnical Bid
List of Existing commitments & Ongoing works- Format-5TrueTechnical Bid
List of works for which tenders acceptence letter received-Format-6TrueTechnical Bid
List of works for which tenders already submitted-Format-7TrueTechnical Bid
Profit and loss ac & Balance sheets for 5 yearsTrueTechnical Bid
Income Tax returns for 5 yearsTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1720509554000
version0
createdDateNone
modifiedDateNone
blockNumberOffice Of the Executive Engineer, PWD Division, 100 bed Hospital road,
streetNone
cityHosapete
stateKarnataka
pin583201
tenderRecallDTONone