3539411 | 127654 | None | code01 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.In cement mortar | Cum | 1080.45 | 1080.45 | 8.28 | False | None | None | False | None | False | 8946.126 | 0 |
3539412 | 127654 | None | code02 | Earth work in surface excavation by manual means for lowering & levelling the ground by chiselling and wedging in Hard rock for all works other than foundation & depth not exceeding 100 mm as per drawing and technical specifications, including setting out, barricading, caution lights, dressing of excavated surfaces, disposing off the excavated spalls/stuff & stacking the selected spall/ stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. | Sqm | 185.85 | 185.85 | 12.25 | False | None | None | False | None | False | 2276.6625 | 0 |
3539413 | 127654 | None | code03 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m | Cum | 254.1 | 254.1 | 2.862 | False | None | None | False | None | False | 727.2342 | 0 |
3539414 | 127654 | None | code04 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 2.862 | False | None | None | False | None | False | 799.3566 | 0 |
3539415 | 127654 | None | code05 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 1.3405 | False | None | None | False | None | False | 8429.667225 | 0 |
3539416 | 127654 | None | code06 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 3.4425 | False | None | None | False | None | False | 23093.839125 | 0 |
3539417 | 127654 | None | code07 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 9958.72 | 9958.72 | 0.6615 | False | None | None | False | None | False | 6587.69328 | 0 |
3539418 | 127654 | None | code08 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and
technical specification | Tonne | 93929.85 | 93929.85 | 0.09 | False | None | None | False | None | False | 8453.6865 | 0 |
3539419 | 127654 | None | code09 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1159.2 | 1159.2 | 11.07 | False | None | None | False | None | False | 12832.344 | 0 |
3539420 | 127654 | None | code10 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 389.55 | 389.55 | 47.33 | False | None | None | False | None | False | 18437.4015 | 0 |
3539421 | 127654 | None | code11 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cementslurry @ 3.3 kg/ m2 including grouting the joints with white cement andmatching pigments etc., complete 600X600 size. | Sqm | 1202.25 | 1202.25 | 7.25 | False | None | None | False | None | False | 8716.3125 | 0 |
3539422 | 127654 | None | code12 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work afterthoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 133.35 | 133.35 | 14.845 | False | None | None | False | None | False | 1979.58075 | 0 |
3539423 | 127654 | None | code13 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 93.45 | 93.45 | 19.035 | False | None | None | False | None | False | 1778.82075 | 0 |
3539424 | 127654 | None | code14 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge | Sqm | 4701.9 | 4701.9 | 4.32 | False | None | None | False | None | False | 20312.208 | 0 |
3539425 | 127654 | None | code15 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kgs | 176.4 | 176.4 | 319.0005 | False | None | None | False | None | False | 56271.6882 | 0 |
3539426 | 127654 | None | code16 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL 9016) sections and with minimum TiO2 (Titanium Dioxide) at 6PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame sash shall be of 1.8+-0.2 mm. Maximum possible size 1519mm x 1519mm. (The cost is inclusive of all fixtures and separate charges for minor TPs shall not be made) | Sqm | 5659.5 | 5659.5 | 13.42 | False | None | None | False | None | False | 75950.49 | 0 |
3539427 | 127654 | None | code17 | Providing and fixing Steel work in built up tubular (round, square orrectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steelprimer, including welding and bolted with special shaped washers etc.complete. Electric resistance or induction butt welded tubes including cost of materials, labour, usage charges of machinery complete as perspecifications and as per directions of the Engineer-in-Charge. | Kgs | 128.1 | 128.1 | 375.72 | False | None | None | False | None | False | 48129.732 | 0 |
3539428 | 127654 | None | code18 | Supplying and fixing new Mangalore tiles on existing reepers. | Sqm | 499.8 | 499.8 | 12.0 | False | None | None | False | None | False | 5997.6 | 0 |
3539429 | 127654 | None | code19 | Providing Mangalore Ridge tiles set in C.M. 1:2 and pointed with C.M. 1:2. | Mtr | 261.45 | 261.45 | 8.0 | False | None | None | False | None | False | 2091.6 | 0 |
3539430 | 127654 | None | code20 | Open Conduit System Supplying heavy gauge PVC conduit pipe …….dia confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20mm dia 2mm thick | Mtr | 69.0 | 69.0 | 30.0 | False | None | None | False | None | False | 2070.0 | 0 |
3539431 | 127654 | None | code21 | Supplying and flush mounting powder coated/galvanised metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way | Each | 177.0 | 177.0 | 1.0 | False | None | None | False | None | False | 177.0 | 0 |
3539432 | 127654 | None | code22 | 10-12Way | Each | 319.0 | 319.0 | 1.0 | False | None | None | False | None | False | 319.0 | 0 |
3539433 | 127654 | None | code23 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Moudule | Each | 175.0 | 175.0 | 1.0 | False | None | None | False | None | False | 175.0 | 0 |
3539434 | 127654 | None | code24 | 12 Moudule | Each | 344.0 | 344.0 | 1.0 | False | None | None | False | None | False | 344.0 | 0 |
3539435 | 127654 | None | code25 | Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVCConduit /casing capping casing capping using 2x1.5Sqmm(Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLSmulti strand PVC insulated copper wire (confirming toIS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for eachoutlet.
Short point up to 3Mtr from tapping point to out let via switch box | Each | 269.0 | 269.0 | 1.0 | False | None | None | False | None | False | 269.0 | 0 |
3539436 | 127654 | None | code26 | 2.2.2 Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch box | Each | 379.0 | 379.0 | 1.0 | False | None | None | False | None | False | 379.0 | 0 |
3539437 | 127654 | None | code27 | 2.2.3 Long point above 6Mtr up to 10Mtr from tapping point to out let via switch box | Each | 555.0 | 555.0 | 1.0 | False | None | None | False | None | False | 555.0 | 0 |
3539438 | 127654 | None | code28 | Supplying and fixing of modular switch & connectedaccessories on existing modular switch plate as per IS 3854and IS 1293. 6Amps one way. | Each | 102.0 | 102.0 | 8.0 | False | None | None | False | None | False | 816.0 | 0 |
3539439 | 127654 | None | code29 | 6Amps 3way socket. | Each | 171.0 | 171.0 | 2.0 | False | None | None | False | None | False | 342.0 | 0 |
3539440 | 127654 | None | code30 | Stepped Fan Regulator Two Module | Each | 357.0 | 357.0 | 1.0 | False | None | None | False | None | False | 357.0 | 0 |
3539441 | 127654 | None | code31 | 32Amps DP switch | Each | 326.0 | 326.0 | 1.0 | False | None | None | False | None | False | 326.0 | 0 |
3539442 | 127654 | None | code32 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper With low conductor resistance single core cable in open or concealed system of wiring with specified IS 694:1990 & Conforming to GTP of GROUP-A 1.5 sqmm | Mtr | 26.0 | 26.0 | 25.0 | False | None | None | False | None | False | 650.0 | 0 |
3539443 | 127654 | None | code33 | 2.5 sqmm | Mtr | 42.0 | 42.0 | 60.0 | False | None | None | False | None | False | 2520.0 | 0 |
3539444 | 127654 | None | code34 | Supplying of ......feet - PVC Batten with integrated LED tube.....W with high quality diffuser with Life of 25000 burninghours & 70% lumen maintenance with CRI 80. PowerInput: 220-240V @ 50/60Hz & Power factor 0.9 along withCE approved. 2 years Warranty against any manufacturingdefect working under standard electrical condition.LED light fighting 1x 4 - 20/22 w | Each | 690.0 | 690.0 | 2.0 | False | None | None | False | None | False | 1380.0 | 0 |
3539445 | 127654 | None | code35 | Fixing all types and all capacities fluorescent/false ceiling/spot light/ CFL fittings indoor on the wall /ceiling/rafters/girders using 23/ 0.0076 twin twisted PVC insulated wires, required nos of round blocks and clamps (if required). a) On wa/ceiling/Rafter/Girders | Each | 122.0 | 122.0 | 2.0 | False | None | None | False | None | False | 244.0 | 0 |
3539446 | 127654 | None | code36 | aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect LED Streetlight 25 W | Each | 2425.0 | 2425.0 | 1.0 | False | None | None | False | None | False | 2425.0 | 0 |
3539447 | 127654 | None | code37 | Supplying and Fixing of........mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket 1x40/2x40 W fluorescent tube street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clA, bolts, and nuts and wiring using suitable capacity wires. Using 25mm dia G.I.Pipe | No | 978.0 | 978.0 | 1.0 | False | None | None | False | None | False | 978.0 | 0 |
3539448 | 127654 | None | code38 | Supplying & Fixing of 70-150 W lamp holder 2 Pin | Each | 63.0 | 63.0 | 2.0 | False | None | None | False | None | False | 126.0 | 0 |
3539449 | 127654 | None | code39 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and coomplete wiring as required. '6-32Amps SP, | Each | 415.0 | 415.0 | 2.0 | False | None | None | False | None | False | 830.0 | 0 |
3539450 | 127654 | None | code40 | 50-63Amps DP | Each | 1102.0 | 1102.0 | 1.0 | False | None | None | False | None | False | 1102.0 | 0 |
3539451 | 127654 | None | code41 | Supplying and fixing regular MCB distribution boards on wall / woodboard/flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting etc., complete. II - Single Door, 12 Way SP &N | Each | 1863.0 | 1863.0 | 1.0 | False | None | None | False | None | False | 1863.0 | 0 |
3539452 | 127654 | None | code42 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipments on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proprotion of salt and charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and checknuts etc, the pipe shall have 16 through holes of 122 mm dia.(68/1) | No | 2999.7 | 2999.7 | 1.0 | False | None | None | False | None | False | 2999.7 | 0 |
3539453 | 127654 | None | code43 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.GI STRIP25X3mm | Mtr | 75.0 | 75.0 | 5.0 | False | None | None | False | None | False | 375.0 | 0 |
3539454 | 127654 | None | code44 | Wiring for lighting/power circuit using one of PVC insulated
1100V grade, stranded Aluminium wire single core in open or concealed system of wiring. 10sqmm | Mtr | 75.0 | 75.0 | 50.0 | False | None | None | False | None | False | 3750.0 | 0 |