tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1721214855000 | 1 | None | None | Buildings | Construction of Ground floor | 4121303.9 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3538350 | 127574 | None | code01 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge with all lead & lifts as directed by the engineer in charge of the work. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 1858.0 | 1858.0 | 29.78 | False | None | None | False | None | False | 55331.24 | 0 | 3538351 | 127574 | None | code02 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer- in-charge. with all lead & lifts as directed by the engineer in charge of the work. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 607.0 | 607.0 | 76.98 | False | None | None | False | None | False | 46726.86 | 0 | 3538352 | 127574 | None | code03 | Earth work excavation by manual means for drains,canals, waste weir,draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. with all lead & lifts as directed by the engineer in charge of the work. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 186.0 | 186.0 | 150.2 | False | None | None | False | None | False | 27937.2 | 0 | 3538353 | 127574 | None | code04 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates with all lead & lifts as directed by the engineer in charge of the work. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 5206.0 | 5206.0 | 44.55 | False | None | None | False | None | False | 231927.3 | 0 | 3538354 | 127574 | None | code05 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost
of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead & lifts as directed by the engineer in charge of the work. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 5979.0 | 5979.0 | 30.7 | False | None | None | False | None | False | 183555.3 | 0 | 3538355 | 127574 | None | code06 | For Additionalities for Formwork,Centring & Scaffolding for columns footings with all lead & lifts as directed by the engineer in charge of the work. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 478.32 | 478.32 | 23.06 | False | None | None | False | None | False | 11030.0592 | 0 | 3538356 | 127574 | None | code07 | For Additionalities for Formwork,Centring & Scaffolding for Plinth Beam with all lead & lifts as directed by the engineer in charge of the work. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 2989.5 | 2989.5 | 7.64 | False | None | None | False | None | False | 22839.78 | 0 | 3538357 | 127574 | None | code08 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) with all lead & lifts as directed by the engineer in charge of the work. First Floor ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 4750.0 | 4750.0 | 77.13 | False | None | None | False | None | False | 366367.5 | 0 | 3538358 | 127574 | None | code09 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead & lifts as directed by the engineer in charge of the work. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 6186.0 | 6186.0 | 85.34 | False | None | None | False | None | False | 527913.24 | 0 | 3538359 | 127574 | None | code10 | For Additionalities for Formwork,Centring & Scaffolding for Columns with all lead & lifts as directed by the engineer in charge of the work. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 4330.2 | 4330.2 | 15.42 | False | None | None | False | None | False | 66771.684 | 0 | 3538360 | 127574 | None | code11 | For Additionalities for Formwork,Centring & Scaffolding for lintels with all lead & lifts as directed by the engineer in charge of the work. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 3711.6 | 3711.6 | 2.52 | False | None | None | False | None | False | 9353.232 | 0 | 3538361 | 127574 | None | code12 | For Additionalities for Formwork,Centring & Scaffolding for Chajjaa with all lead & lifts as directed by the engineer in charge of the work. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 2783.7 | 2783.7 | 0.57 | False | None | None | False | None | False | 1586.709 | 0 | 3538362 | 127574 | None | code13 | For Additionalities for Formwork,Centring & Scaffolding for Roof Beam with all lead & lifts as directed by the engineer in charge of the work. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 3711.6 | 3711.6 | 15.92 | False | None | None | False | None | False | 59088.672 | 0 | 3538363 | 127574 | None | code14 | For Additionalities for Formwork,Centring & Scaffolding for Slab with all lead & lifts as directed by the engineer in charge of the work. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 3093.0 | 3093.0 | 38.54 | False | None | None | False | None | False | 119204.22 | 0 | 3538364 | 127574 | None | code15 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming andwatering, lead up to 50 m and lift upto 1.5 m. with all lead & lifts as directed by the engineer in charge of the work. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 204.0 | 204.0 | 161.52 | False | None | None | False | None | False | 32950.08 | 0 | 3538365 | 127574 | None | code16 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. with all lead & lifts as directed by the engineer in charge of the work. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 6948.0 | 6948.0 | 70.79 | False | None | None | False | None | False | 491848.92 | 0 | 3538366 | 127574 | None | code17 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 ( M 10) Using 20 mm nominal size graded crushed coarse aggregates with all lead & lifts as directed by the engineer in charge of the work. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 5728.0 | 5728.0 | 2.03 | False | None | None | False | None | False | 11627.84 | 0 | 3538367 | 127574 | None | code18 | Providing Jungle wood such as Nerale, Neem wrought and putup for purlins, common rafters and similar work including cost of materials, labour, usage charges complete as per specifications. with all lead & lifts as directed by the engineer in charge of the work. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 43339.0 | 43339.0 | 0.248 | False | None | None | False | None | False | 10748.072 | 0 | 3538368 | 127574 | None | code19 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications with all lead & lifts as directed by the engineer in charge of the work. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Each | 1485.0 | 1485.0 | 3.0 | False | None | None | False | None | False | 4455.0 | 0 | 3538369 | 127574 | None | code20 | Fixing of window frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debries with lead upto 50 m. including cost of materials, labour charges, complete as per specifications with all lead & lifts as directed by the engineer in charge of the work. Windows Ground+First floor floor ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Each | 1010.0 | 1010.0 | 16.0 | False | None | None | False | None | False | 16160.0 | 0 | 3538370 | 127574 | None | code21 | Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with, stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures ) with all lead & lifts as directed by the engineer in charge of the work. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Sqm | 4026.0 | 4026.0 | 5.04 | False | None | None | False | None | False | 20291.04 | 0 | 3538371 | 127574 | None | code22 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm,with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. with all lead & lifts as directed by the engineer in charge of the work. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Sqm | 6563.0 | 6563.0 | 5.04 | False | None | None | False | None | False | 33077.52 | 0 | 3538372 | 127574 | None | code23 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. with all lead & lifts as directed by the engineer in charge of the work. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Sqm | 3660.0 | 3660.0 | 24.75 | False | None | None | False | None | False | 90585.0 | 0 | 3538373 | 127574 | None | code24 | Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc.125x65x2.12mm with all lead & lifts as directed by the engineer in charge of the work. Providing and fixing fixtures for Door & Windows ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Each | 38.0 | 38.0 | 78.0 | False | None | None | False | None | False | 2964.0 | 0 | 3538374 | 127574 | None | code25 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. with all lead & lifts as directed by the engineer in charge of the work. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Each | 30.0 | 30.0 | 56.0 | False | None | None | False | None | False | 1680.0 | 0 | 3538375 | 127574 | None | code26 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding with all lead & lifts as directed by the engineer in charge of the work. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Kg | 159.0 | 159.0 | 1009.26 | False | None | None | False | None | False | 160472.34 | 0 | 3538376 | 127574 | None | code27 | Providing Thermo-Mechanically Treated bars of grade Fe-500 Steel reinforcement for R.C.C. work ready to use "cut and bend" rebars of approved make from factory/workshop to construction site including placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications with all lead & lifts as directed by the engineer in charge of the work. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Kg | 78.0 | 78.0 | 10322.71 | False | None | None | False | None | False | 805171.38 | 0 | 3538377 | 127574 | None | code28 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. with all lead & lifts as directed by the engineer in charge of the work. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Sqm | 299.0 | 299.0 | 55.58 | False | None | None | False | None | False | 16618.42 | 0 | 3538378 | 127574 | None | code29 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. with all lead & lifts as directed by the engineer in charge of the work. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Sqm | 294.0 | 294.0 | 435.46 | False | None | None | False | None | False | 128025.24 | 0 | 3538379 | 127574 | None | code30 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. with all lead & lifts as directed by the engineer in charge of the work. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Sqm | 262.0 | 262.0 | 218.08 | False | None | None | False | None | False | 57136.96 | 0 | 3538380 | 127574 | None | code31 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge with all lead & lifts as directed by the engineer in charge of the work. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Sqm | 83.0 | 83.0 | 431.29 | False | None | None | False | None | False | 35797.07 | 0 | 3538381 | 127574 | None | code32 | Providing and fixing 304- grade stainless steel hand rails of 14-gauge pipes for Ramps staircase made out of stainless steel hallow pipes, using 50mm dia for verticals @1.60 mtr c/c fixed to the ramps or steps by drilling with bolts and 1OOmm dia MS base plates 1Omm gauge for fixing of Vertical pipes 4 - Nos anchor bolts & 40mm dia pipes fixed horizontally for 2-rows top, one pipes fixed with vertical pipes another one fixed with elbows and 25mm dia pipes are fixed horizontally for 2-rows below top measure@ equal intervals including cutting, welding, bending wherever necessary with suitable caps @ tops, bottoms & corners finishing with mat I shining etc., complete including cost and conveyance of all materials, labour for all items of work, HOM with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. Ramps or Staircase for physically challenged with all lead & lifts as directed by the engineer in charge of the work. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Sqm | 6021.0 | 6021.0 | 6.4 | False | None | None | False | None | False | 38534.4 | 0 | 3538382 | 127574 | None | code33 | Flooring with 25mm thick polished shahabad slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. with all lead & lifts as directed by the engineer in charge of the work. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Sqm | 1312.0 | 1312.0 | 256.36 | False | None | None | False | None | False | 336344.32 | 0 | 3538383 | 127574 | None | code34 | Providing & fixing on wall face unplasticised Rigid PVC rain water pipes conferming to IS :13592 type A Including Jointing with seal ring conferming to IS 5382 leaving to 10 mm gap for thermal expansion (i)Single socketed pipes 75 mm daimeter with all lead & lifts as directed by the engineer in charge of the work. 75mm dia ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Mtr | 177.0 | 177.0 | 15.0 | False | None | None | False | None | False | 2655.0 | 0 | 3538384 | 127574 | None | code35 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. with all lead & lifts as directed by the engineer in charge of the work. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Sqm | 105.0 | 105.0 | 550.58 | False | None | None | False | None | False | 57810.9 | 0 | 3538385 | 127574 | None | code36 | Providing wall black boards in CM 1:3 with two coats of black paint including finishing etc., including cost of materials, labour, HOM complete as per specifications..(PWD SR 2018-2019 page No. 268 I. No.37.3 ) with all lead & lifts as directed by the engineer in charge of the work. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Each | 772.0 | 772.0 | 4.0 | False | None | None | False | None | False | 3088.0 | 0 | 3538386 | 127574 | None | code37 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Sqm | 208.0 | 208.0 | 153.72 | False | None | None | False | None | False | 31973.76 | 0 | 3538387 | 127574 | None | code38 | Applying priming coat: With ready mixed pink or Grey primer ofapproved brand and manufacture on wood work (hard and soft wood)including preparing the surface after thorougly cleaning oil, grease,dirt and foreign matter, cost of materials, labour complete as perspecifications and as per directions of Engineer-in-charge. with all lead & lifts as directed by the engineer in charge of the work. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Sqm | 41.0 | 41.0 | 11.34 | False | None | None | False | None | False | 464.94 | 0 | 3538388 | 127574 | None | code39 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. with all lead & lifts as directed by the engineer in charge of the work. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Sqm | 105.0 | 105.0 | 11.34 | False | None | None | False | None | False | 1190.7 | 0 |
| 1721214855000 | 0 | None | None | Buildings | Electrification to Building | 87238.7 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3538389 | 127575 | None | code01 | Suppling heavy gauge P V C Conduit pipe …. Mm dai … mm thick Confireming to I S 2509 with suitable size bends P V C Junction boxes ETC and running before concreting slab the conduite shouldbe tide to the reinforcement rod by using binding wires and pipe ends should be covered using P V C end enclosures run with 18 SWG GI fish wire wherever necessary .19/20mmdai 2mm thick ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Mtr | 61.0 | 61.0 | 185.0 | False | None | None | False | None | False | 11285.0 | 0 | 3538390 | 127575 | None | code02 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr from tapping point to out let via switch box Short point Up to 3Mt from tapping point to out let via switch box ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Point | 276.0 | 276.0 | 25.0 | False | None | None | False | None | False | 6900.0 | 0 | 3538391 | 127575 | None | code03 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 1.00 sqmm ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Mtr | 18.0 | 18.0 | 510.0 | False | None | None | False | None | False | 9180.0 | 0 | 3538392 | 127575 | None | code04 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 1.5 sqmm ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Mtr | 26.0 | 26.0 | 680.0 | False | None | None | False | None | False | 17680.0 | 0 | 3538393 | 127575 | None | code05 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 2.5 sqmm ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Mtr | 40.0 | 40.0 | 175.0 | False | None | None | False | None | False | 7000.0 | 0 | 3538394 | 127575 | None | code06 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.4-5 Way . complete as per direction of engineer in charge. 4-5 way ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Each | 122.0 | 122.0 | 6.0 | False | None | None | False | None | False | 732.0 | 0 | 3538395 | 127575 | None | code07 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.6-8Way . complete as per direction of engineer in charge. 8 way ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Each | 195.0 | 195.0 | 2.0 | False | None | None | False | None | False | 390.0 | 0 | 3538396 | 127575 | None | code08 | Supplying and fixing of modular Stepped Fan Regulator. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Each | 313.0 | 313.0 | 6.0 | False | None | None | False | None | False | 1878.0 | 0 | 3538397 | 127575 | None | code09 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Each | 2085.0 | 2085.0 | 6.0 | False | None | None | False | None | False | 12510.0 | 0 | 3538398 | 127575 | None | code10 | Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Each | 150.0 | 150.0 | 6.0 | False | None | None | False | None | False | 900.0 | 0 | 3538399 | 127575 | None | code11 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854and IS 1293 6 Amps 3 way Socket ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Each | 162.0 | 162.0 | 12.0 | False | None | None | False | None | False | 1944.0 | 0 | 3538400 | 127575 | None | code12 | Supplying and fixing of 400 Watts Dimmer ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Each | 318.0 | 318.0 | 6.0 | False | None | None | False | None | False | 1908.0 | 0 | 3538401 | 127575 | None | code13 | Supplying and fixing of 32 Ams D P Switch ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Each | 375.0 | 375.0 | 6.0 | False | None | None | False | None | False | 2250.0 | 0 | 3538402 | 127575 | None | code14 | Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 W ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Each | 375.0 | 375.0 | 19.0 | False | None | None | False | None | False | 7125.0 | 0 | 3538403 | 127575 | None | code15 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 6-32 A DP ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Each | 1104.0 | 1104.0 | 2.0 | False | None | None | False | None | False | 2208.0 | 0 | 3538404 | 127575 | None | code16 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Each | 2999.7 | 2999.7 | 1.0 | False | None | None | False | None | False | 2999.7 | 0 | 3538405 | 127575 | None | code17 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.12 SWG GI Wire ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Each | 14.0 | 14.0 | 1.0 | False | None | None | False | None | False | 14.0 | 0 | 3538406 | 127575 | None | code18 | Supplying and fixing of class A (medium duty) GI pipe of wall thickness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV.40mm 110 mm dai outer dai ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Mtr | 335.0 | 335.0 | 1.0 | False | None | None | False | None | False | 335.0 | 0 |
|
|
---|