createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1721116202025
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd589000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose25-07-2024 17:00:00
tenderQueryClose24-07-2024 16:00:00
technicalBidOpen26-07-2024 17:30:00
publishedDate18-07-2024 16:53:04
publishedByPostPWD_EE_DIV_HSPT
publishedByUserKPE10057 - DEVADASA T
bidValidityPeriod90
noOfCalls1
preBidMeetingDate23-07-2024 14:06:17
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonExecutive Engineer
splitEmdRequiredYnTrue
emdBankGuarantee489000.00
emdCash100000.00
bgValidityPeriod135
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber080394200231
mobileNumberNone
tenderSupplierListNone
tenderSchedule
createdTs1721116202064
version11
createdDateNone
modifiedDateNone
tenderNumberPWD/2024-25/BD/WORK_INDENT11058
titleConstruction of New CHC Hospital Building At Ujjini, Kotturu Taluk
descriptionConstruction of New CHC Hospital Building At Ujjini, Kotturu tauk KKRDB-MICRO Plan 2023-24
categoryWORKS
categoryTextWorks
ecv39200934.20
deptNamePublic Works Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location1694
locationNamePWD Division Office Hosapete
provisionalAmount47699000.0
groupOverheadTotal0.0
fileNumberAEE/PWD/KDL/KKRDB-MICRO/UJJINI/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17211162020001NoneNoneBuildingsPart-I KKRDB SCP (Work code VNR23S4123152)8987695.54
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3532408127189NoneCSR 2023-24 Vol-3 P No.9 Item No.2.5(ii)AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm412.65412.65162.5FalseNoneNoneFalseNoneFalse67055.6250
3532409127189NoneCSR 2023-24 Vol-1 P No.8 Item No.1.12Surface Excavation Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.Cum99.7599.75348.3FalseNoneNoneFalseNoneFalse34742.9250
3532410127189NoneCSR 2023-24 Vol-1 P No.8 Item No.1.14.1EarthWork Excavation (Soil) Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m Cum107.1107.11389.69FalseNoneNoneFalseNoneFalse148835.7990
3532411127189NoneCSR 2023-24 Vol-1 P No.15 Item No.2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates Cum5947.25947.2248.7FalseNoneNoneFalseNoneFalse1479068.640
3532412127189NoneCSR 2023-24 Vol-2 P No.59 Item No.9.1Providing and laying Cement concrete flooring 40 mm thick with 20mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete. Sqm473.55473.55265.0FalseNoneNoneFalseNoneFalse125490.750
3532413127189NoneCSR 2023-24 Vol-2 P No.5 Item No.4.1Chemical Treatment Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. Sqm123.9123.91389.0FalseNoneNoneFalseNoneFalse172097.10
3532414127189NoneCSR 2023-24 Vol-1 P No.7 Item No.1.11Filling Gravel Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum454.65454.651430.67FalseNoneNoneFalseNoneFalse650454.11550
3532415127189NoneCSR 2023-24 Vol-1 P No.15 Item No.2.2.3RCC WORKS Footing RCC Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6652.86652.8161.39FalseNoneNoneFalseNoneFalse1073695.3920
3532416127189NoneCSR 2023-24 Vol-1 P No.17 Item No.2.4.3Below plinth Column Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Cum6652.86652.827.46FalseNoneNoneFalseNoneFalse182685.8880
3532417127189NoneCSR 2023-24 Vol-1 P No.17 Item No.2.3.2Plinth Beam Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6804.06804.087.56FalseNoneNoneFalseNoneFalse595758.240
3532418127189NoneCSR 2023-24 Vol-1 P No.18 Item No.2.11Steel Upto Plinth "Steel Fabrication Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a) Buildings"t93929.8593929.8527.01FalseNoneNoneFalseNoneFalse2537045.24850
3532419127189NoneCSR 2023-24 Vol-1 P No.111 Item No.1Form Work and Centering (Addendum - Vol-1, Page No -111) (% On Finished Rate of Concrete per cum) Foundation upto Plinth a. Isolated (3 PERCENT) Cum199.58199.58161.37FalseNoneNoneFalseNoneFalse32206.22460
3532420127189NoneCSR 2023-24 Vol-1 P No.111 Item No.3Formwork for Foundation, Sub structure of Cross drainages (5%) Footing & Plinth Beam PCC Cum297.36297.36248.68FalseNoneNoneFalseNoneFalse73947.48480
3532421127189NoneCSR 2023-24 Vol-1 P No.111 Item No.9Formwork for RCC Columns / Shaft (Slip Centering) ( 70% ) Column Cum4656.964656.9627.46FalseNoneNoneFalseNoneFalse127880.12160
3532422127189NoneCSR 2023-24 Vol-1 P No.111 Item No.2Formwork for Plinth Beams of Buildings (50%) Plinth Beam Cum3402.03402.062.46FalseNoneNoneFalseNoneFalse212488.920
3532423127189NoneCSR 2023-24 Vol-1 P No.112 Item No.11Formwork for Earth retaining structures ( 10% ) RCC Curtain wall Cum680.4680.426.25FalseNoneNoneFalseNoneFalse17860.50
3532424127189NoneCSR 2023-24 Vol-1 P No.16 Item No.2.5.2ABOVE PLINTH LEVEL - CIVIL WORKS CONCRETE Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)Cum7185.157185.157.44FalseNoneNoneFalseNoneFalse53457.5160
3532425127189NoneCSR 2023-24 Vol-1 P No.16 Item No.2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6911.436911.430.16FalseNoneNoneFalseNoneFalse1105.82880
3532426127189NoneCSR 2023-24 Vol-1 P No.16 Item No.2.5.2RCC Sill Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7185.157185.151.49FalseNoneNoneFalseNoneFalse10705.87350
3532427127189NoneCSR 2023-24 Vol-1 P No.16 Item No.2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7260.467260.460.03FalseNoneNoneFalseNoneFalse217.81380
3532428127189NoneCSR 2023-24 Vol-1 P No.16 Item No.2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Cum7185.157185.15184.26FalseNoneNoneFalseNoneFalse1323935.7390
3532429127189NoneCSR 2023-24 Vol-1 P No.16 Item No.2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Cum7263.917263.915.4FalseNoneNoneFalseNoneFalse39225.1140
3532430127189NoneCSR 2023-24 Vol-1 P No.16 Item No.2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) Cum7185.157185.153.86FalseNoneNoneFalseNoneFalse27734.6790
17211162020001NoneNoneBuildingsPart-II KKRDB TSP (Work code VNR23S4123253)13221227.92
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3532431127190NoneCSR 2023-24 Vol-1 P No.16 Item No.2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) vM25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7185.157185.1580.9FalseNoneNoneFalseNoneFalse581278.6350
3532432127190NoneCSR 2023-24 Vol-1 P No.16 Item No.2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates INCLUDING LIFT CHARGES Cum7328.857328.8537.85FalseNoneNoneFalseNoneFalse277396.97250
3532433127190NoneCSR 2023-24 Vol-1 P No.111 Item No.9Form Work and Centering Addendum - Vol-1 Page No -111 Percent On Finished Rate of Concrete per cum RCC Columns / Shaft (Slip Centering) ( 70% ) Columns Qty Cum5029.615029.6132.01FalseNoneNoneFalseNoneFalse160997.81610
3532434127190NoneCSR 2023-24 Vol-1 P No.111 Item No.9Form Work and Centering Addendum - Vol-1, Page No -111) percent On Finished Rate of Concrete per cum RCC Columns / Shaft Slip Centering 70 percent Columns Qty Cum5084.745084.7435.39FalseNoneNoneFalseNoneFalse179948.94860
3532435127190NoneCSR 2023-24 Vol-1 P No.112 Item No.14Form Work and Centering Addendum - Vol-1, Page No -111 PERCENT On Finished Rate of Concrete per CUMCum4311.094311.0937.82FalseNoneNoneFalseNoneFalse163045.42380
3532436127190NoneCSR 2023-24 Vol-1 P No.112 Item No.14Form Work and Centering Addendum - Vol-1, Page No -111 PERCENT On Finished Rate of Concrete per CUMCum4358.354358.3537.85FalseNoneNoneFalseNoneFalse164963.54750
3532437127190NoneCSR 2023-24 Vol-1 P No.112 Item No.15Form Work and Centering PERCENT On Finished Rate of Concrete per CUMCum3592.583592.58174.75FalseNoneNoneFalseNoneFalse627803.3550
3532438127190NoneCSR 2023-24 Vol-1 P No.112 Item No.15Form Work and Centering PERCENT On Finished Rate of Concrete per CUM TERRACE FLOOR 50 PERCENTCum3631.963631.965.4FalseNoneNoneFalseNoneFalse19612.5840
3532439127190NoneCSR 2023-24 Vol-1 P No.112 Item No.16Form Work and Centering PERCENT On Finished Rate of Concrete per CUM Staircase and other similar structures (50%) Staircase Concrete Quantity GROUND FLOOR Cum3592.583592.5831.88FalseNoneNoneFalseNoneFalse114531.45040
3532440127190NoneCSR 2023-24 Vol-1 P No.112 Item No.20Form Work and Centering PERCENT On Finished Rate of Concrete per CUM Cum3233.323233.321.49FalseNoneNoneFalseNoneFalse4817.64680
3532441127190NoneCSR 2023-24 Vol-1 P No.112 Item No.20Form Work and Centering PERCENT On Finished Rate of Concrete per CUMCum3268.763268.760.03FalseNoneNoneFalseNoneFalse98.06280
3532442127190NoneCSR 2023-24 Vol-1 P No.18 Item No.2.11Steel Fabrication Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a) BuildingsMT93929.8593929.8533.45FalseNoneNoneFalseNoneFalse3141953.48250
3532443127190NoneCSR 2023-24 Vol-1 P No.18 Item No.2.11Steel Fabrication Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a) BuildingsMT94959.594959.58.08FalseNoneNoneFalseNoneFalse767272.760
3532444127190NoneCSR 2023-24 Vol-2 P No.17 Item No.6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 5.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1375.51375.51516.84FalseNoneNoneFalseNoneFalse2086413.420
3532445127190NoneCSR 2023-24 Vol-2 P No.17 Item No.6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 5.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1390.581390.58396.38FalseNoneNoneFalseNoneFalse551198.10040
3532446127190NoneCSR 2023-24 Vol-2 P No.17 Item No.6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1159.21159.2185.45FalseNoneNoneFalseNoneFalse214973.640
3532447127190NoneCSR 2023-24 Vol-2 P No.100 Item No.12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum103755.75103755.750.29FalseNoneNoneFalseNoneFalse30089.16750
3532448127190NoneCSR 2023-24 Vol-2 P No.105 Item No.12.57.7Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specificationSqm5208.05208.05.33FalseNoneNoneFalseNoneFalse27758.640
3532449127190NoneCSR 2023-24 Vol-2 P No.104 Item No.12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. Nos1066.81066.812.0FalseNoneNoneFalseNoneFalse12801.60
3532450127190NoneCSR 2023-24 Vol-2 P No.105 Item No.12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.Nos126.0126.04.0FalseNoneNoneFalseNoneFalse504.00
3532451127190NoneCSR 2023-24 Vol-2 P No.105 Item No.12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.Nos1169.71169.74.0FalseNoneNoneFalseNoneFalse4678.80
3532452127190NoneCSR 2023-24 Vol-2 P No.105 Item No.12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1104.61104.62.0FalseNoneNoneFalseNoneFalse2209.20
3532453127190NoneCSR 2023-24 Vol-2 P No.105 Item No.12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNos248.85248.858.0FalseNoneNoneFalseNoneFalse1990.80
3532454127190NoneCSR 2023-24 Vol-2 P No.105 Item No.12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNos136.5136.58.0FalseNoneNoneFalseNoneFalse1092.00
3532455127190NoneCSR 2023-24 Vol-2 P No.105 Item No.12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms Nos57.7557.754.0FalseNoneNoneFalseNoneFalse231.00
3532456127190NoneCSR 2023-24 Vol-2 P No.107 Item No.12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete :" 125X 85X 5.5 mm heavy type) Nos288.75288.7516.0FalseNoneNoneFalseNoneFalse4620.00
3532457127190NoneCSR 2023-24 Vol-2 P No.107 Item No.12.76.3 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 150x10mm Each303.45303.452.0FalseNoneNoneFalseNoneFalse606.90
3532458127190NoneCSR 2023-24 Vol-2 P No.69 Item No.10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmEach63.063.08.0FalseNoneNoneFalseNoneFalse504.00
3532459127190NoneCSR 2023-24 Vol-2 P No.205 Item No.20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications.Mtr54.654.615.6FalseNoneNoneFalseNoneFalse851.760
3532460127190NoneCSR 2023-24 Vol-2 P No.110 Item No.12.90Providing fixing of 3track 2-panel sliding windows made out of multi chambered UPVC Matching to RAL 9016 sections and with minimum TiO2 Titanium Dioxide at 6 PHR with TPE Thermo Plastic Elastomer and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm 75mm with GI reinforcement of 2mm and mesh sash of size 37mm 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware Multi point locking system with touch lock. Wall thickness of frame sash shall be of 2mm 2.5mm. Maximum possible size 2419mm 2200mm. The cost is inclusive of all fixtures and separate charges for minor T PSs shall not be madeSqm7070.77070.7112.2FalseNoneNoneFalseNoneFalse793332.540
3532461127190NoneCSR 2023-24 Vol-2 P No.110 Item No.12.90Providing fixing of 3track 2-panel sliding windows made out of multi chambered UPVC Matching to RAL 9016 sections and with minimum TiO2 Titanium Dioxide at 6 PHR with TPE Thermo Plastic Elastomer and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm 75mm with GI reinforcement of 2mm and mesh sash of size 37mm 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware Multi point locking system with touch lock. Wall thickness of frame sash shall be of 2mm 2.5mm. Maximum possible size 2419mm 2200mm. The cost is inclusive of all fixtures and separate charges for minor T PSs shall not be madeSqm7148.217148.212.7FalseNoneNoneFalseNoneFalse19300.1670
3532462127190NoneCSR 2023-24 Vol-2 P No.109 Item No.12.85Providing fixing of louvered ventilator made out of multi chambered UPVC Matching to RAL 9016 sections and with minimum TiO2 Titanium Dioxide at 6 PHR with TPE Thermo Plastic Elastomer and lead free with gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium powder coated in white will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm 1000mm. The cost is inclusive of all fixtures and separate charges for minor TPS shall not be made Sqm6004.956004.954.68FalseNoneNoneFalseNoneFalse28103.1660
3532463127190NoneCSR 2023-24 Vol-2 P No.104 Item No.12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 no's of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.Sqm333.9333.928.35FalseNoneNoneFalseNoneFalse9466.0650
3532464127190NoneCSR 2023-24 Vol-2 P No.104 Item No.12.55.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.Sqm2484.32484.328.35FalseNoneNoneFalseNoneFalse70429.9050
3532465127190NoneCSR 2023-24 Vol-2 P No.111 Item No.12.92Providing& fixing of Openable door made out of multi chambered UPVC Matching to RAL-9016 sections and with minimum TiO2 Titanium Dioxide) at 6PHR with TPV Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Co extruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge AND Multi point locking system with Handle. Wall thickness of frameAND sash shall be of 2mm 2.5mm. Maximum possible size 1900mm x 2400mm. The cost is inclusive of all fixtures and separate charges for minor TPS shall not be made)Sqm6557.256557.2577.07FalseNoneNoneFalseNoneFalse505367.25750
3532466127190NoneCSR 2023-24 Vol-2 P No.86 Item No.11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Kg176.4176.42454.48FalseNoneNoneFalseNoneFalse432970.2720
3532467127190NoneCSR 2023-24 Vol-2 P No.86 Item No.11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Kg178.33178.3356.7FalseNoneNoneFalseNoneFalse10111.3110
3532468127190NoneCSR 2023-24 Vol-2 P No.47 Item No.8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm52.552.5116.88FalseNoneNoneFalseNoneFalse6136.20
3532469127190NoneCSR 2023-24 Vol-2 P No.47 Item No.8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm53.5553.552.7FalseNoneNoneFalseNoneFalse144.5850
3532470127190NoneCSR 2023-24 Vol-2 P No.48 Item No.8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm175.35175.35116.88FalseNoneNoneFalseNoneFalse20494.9080
3532471127190NoneCSR 2023-24 Vol-2 P No.48 Item No.8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm178.86178.862.7FalseNoneNoneFalseNoneFalse482.9220
3532472127190NoneCSR 2023-24 Vol-2 P No.47 Item No.8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm55.6555.657.2FalseNoneNoneFalseNoneFalse400.680
3532473127190NoneCSR 2023-24 Vol-2 P No.54 Item No.8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer in Charge. Final coat to be done in 1 or 2 layers without gap of time. Sqm710.85710.857.2FalseNoneNoneFalseNoneFalse5118.120
3532474127190NoneCSR 2023-24 Vol-2 P No.85 Item No.11.28Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Kg593.25593.25358.2FalseNoneNoneFalseNoneFalse212502.150
3532475127190NoneCSR 2023-24 Vol-2 P No.43 Item No.8.10Ceiling Plastering Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm221.55221.55301.96FalseNoneNoneFalseNoneFalse66899.2380
3532476127190NoneCSR 2023-24 Vol-2 P No.43 Item No.8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm225.98225.9834.0FalseNoneNoneFalseNoneFalse7683.320
3532477127190NoneCSR 2023-24 Vol-2 P No.41 Item No.8.1.1Wall smooth Plastering Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm267.75267.751988.15FalseNoneNoneFalseNoneFalse532327.16250
3532478127190NoneCSR 2023-24 Vol-2 P No.41 Item No.8.1.1Wall smooth Plastering Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm270.69270.6969.67FalseNoneNoneFalseNoneFalse18858.97230
3532479127190NoneCSR 2023-24 Vol-2 P No.42 Item No.8.7Outside Plastering Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm384.3384.31064.31FalseNoneNoneFalseNoneFalse409014.3330
3532480127190NoneCSR 2023-24 Vol-2 P No.42 Item No.8.7Outside Plastering Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm388.51388.51686.99FalseNoneNoneFalseNoneFalse266902.48490
3532481127190NoneCSR 2023-24 Vol-2 P No.41 Item No.8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm309.75309.751379.76FalseNoneNoneFalseNoneFalse427380.660
3532482127190NoneCSR 2023-24 Vol-2 P No.65 Item No.9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. Sqm1521.451521.45153.51FalseNoneNoneFalseNoneFalse233557.78950
17211162020001NoneNoneBuildingsPart-III KKRDB Gen (Work code VNR23S4123320)6424741.27
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3532483127191NoneCSR 2023-24 Vol-2 P No.65 Item No.9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.Sqm1521.451521.45845.38FalseNoneNoneFalseNoneFalse1286203.4010
3532484127191NoneCSR 2023-24 Vol-2 P No.60 Item No.9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm Sqm1202.251202.25884.95FalseNoneNoneFalseNoneFalse1063931.13750
3532485127191NoneCSR 2023-24 Vol-2 P No.60 Item No.9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. Sqm933.45933.4566.58FalseNoneNoneFalseNoneFalse62149.1010
3532486127191NoneCSR 2023-24 Vol-2 P No.64 Item No.9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications. Sqm5594.45594.476.55FalseNoneNoneFalseNoneFalse428251.320
3532487127191NoneCSR 2023-24 Vol-2 P No.69 Item No.10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2 Sqm4133.854133.859.58FalseNoneNoneFalseNoneFalse39602.2830
3532488127191NoneCSR 2023-24 Vol-2 P No.69 Item No.10.2Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. m344.4344.412.78FalseNoneNoneFalseNoneFalse4401.4320
3532489127191NoneCSR 2023-24 Vol-2 P No.69 Item No.10.4Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. Each620.55620.5538.4FalseNoneNoneFalseNoneFalse23829.120
3532490127191NoneCSR 2023-24 Vol-2 P No.65 Item No.9.40Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, grinding the edge to half/full round wherever required, labour, curing complete as per specification. Sqm978.6978.679.1FalseNoneNoneFalseNoneFalse77407.260
3532491127191NoneCSR 2023-24 Vol-2 P No.27 Item No.7.40.2Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main """"T"""" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross """"T"""" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main """"T"""" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross """"T"""" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main """"T"""" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge." GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.Sqm1795.51795.5754.16FalseNoneNoneFalseNoneFalse1354094.280
3532492127191NoneCSR 2023-24 Vol-2 P No.27 Item No.7.40.2Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main """"T"""" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross """"T"""" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main """"T"""" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross """"T"""" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main """"T"""" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge." GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. Sqm1795.51795.566.58FalseNoneNoneFalseNoneFalse119544.390
3532493127191NoneCSR 2023-24 Vol-2 P No.50 Item No.8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge Sqm105.0105.02290.0FalseNoneNoneFalseNoneFalse240450.00
3532494127191NoneCSR 2023-24 Vol-2 P No.50 Item No.8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge Sqm107.1107.1103.68FalseNoneNoneFalseNoneFalse11104.1280
3532495127191NoneCSR 2023-24 Vol-2 P No.51 Item No.8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. Sqm55.6555.652290.0FalseNoneNoneFalseNoneFalse127438.50
3532496127191NoneCSR 2023-24 Vol-2 P No.51 Item No.8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. Sqm56.7656.76103.68FalseNoneNoneFalseNoneFalse5884.87680
3532497127191NoneCSR 2023-24 Vol-2 P No.50 Item No.8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. Sqm115.5115.52290.0FalseNoneNoneFalseNoneFalse264495.00
3532498127191NoneCSR 2023-24 Vol-2 P No.50 Item No.8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. Sqm117.81117.81103.68FalseNoneNoneFalseNoneFalse12214.54080
3532499127191NoneCSR 2023-24 Vol-2 P No.46 Item No.8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm182.7182.7532.16FalseNoneNoneFalseNoneFalse97225.6320
3532500127191NoneCSR 2023-24 Vol-2 P No.46 Item No.8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR Sqm186.35186.35343.5FalseNoneNoneFalseNoneFalse64011.2250
3532501127191NoneCSR 2023-24 Vol-2 P No.45 Item No.8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Front & Casuality Side GROUND FLOOR Sqm297.15297.15532.155FalseNoneNoneFalseNoneFalse158129.858250
3532502127191NoneCSR 2023-24 Vol-2 P No.45 Item No.8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR Sqm303.09303.09343.5FalseNoneNoneFalseNoneFalse104111.4150
3532503127191NoneCSR 2023-24 Vol-2 P No.54 Item No.8.80Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth. m69.369.31347.0FalseNoneNoneFalseNoneFalse93347.10
3532504127191NoneCSR 2023-24 Vol-2 P No.77 Item No.11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. TERRACE FLOOR Head room door Sqm4543.184543.182.1FalseNoneNoneFalseNoneFalse9540.6780
3532505127191NoneCSR 2023-24 Vol-2 P No.44 Item No.8.16.4Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. m8.48.4245.2FalseNoneNoneFalseNoneFalse2059.680
3532506127191NoneCSR 2023-24 Vol-2 P No.44 Item No.8.16.4Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR W1 m8.578.575.7FalseNoneNoneFalseNoneFalse48.8490
3532507127191NoneCSR 2023-24 Vol-2 P No.33 Item No.7.55Providing & Fixing of Anti Microbial Bio-Safe Coated Integral Densified Tegular/Butt edged Eco Friendly Lightweight Calcium Silicate Suspended Ceiling System without perforation Plain/Designer ceiling Tiles in Module Size of 600x600x15mm with Exposed T24 mm Grid for Hospital Institutions, Laboratories, Health Care Units, Offices. The Anti Microbial Bio-Safe lightweight calcium Silicate ceiling tiles shall be made from Non Cementitious Hydrated Calcium Silicate Slurry/Mixture, Reinforced recycled material with fibers and natural fillers. Free from Formaldehyde and other harmful materials. Doesn't contain any toxic ingredients. The Tiles should have Anti Microbial Bio-Safe Coating on front and back sides of tiles confirming to JIS-Z2801 and ASTM G-21 standard by NABL accredited Labs and found to be completely protected from Bacteria, Fungi, Yeast and Mould when exposed to these organisms both room temperature and AC temperature. Tiles should be protected and is free from colony forming units. The Tiles should have Humidity Resistance (RH) of 100%, Water Resistance, Non Combustible: as per BS:476 Part-4, Fire Performance: as per BS:476 Part-6 for Fire Propagation, as per BS:476 Part-7 for Surface Spread of Flame, As per UK standards Fire Performance A1-S1-d0, Thermal Conductivity K= 0.048 to 0.050 w/m K as per ECBC code 2007, NRC(Noise Reduction Coefficient ) 0.1 to 0.15 (Plain and Designer tiles) as per IS 8225:1987, Sound Attenuation (STA) 30-32dB, Thickness of tile should be 15mm thick with 450 kg/m3 density all around on edge resting portion with Integral Densified edge and 10mm thick with 350 kg/m3 density in the center portion of the body, Light Reflectance 85PERCENT, Weight of material is 5-5.5 kg/m2 and Suitable for Green Building application with Inorganic Recycled content of 46- 50% out of which 18-20% should be FLY ASH and meets the GRIHA & SVAGRIHA norms under the categories: GRIHA V.2015 criterion:11&12, GRIHA V.3 criterion: 17&29 and SVAGRIHA criterion:12. The tiles Shall be laid on 24mm Wide T-Sections Flanges colour white having rotary stitching on all T sections i.e. the Main runner with a web height of 38mm and 1200mm & 600mm Cross Tees with a web height of 32mm having thickness of 0.33mm and Wall angle of 24*24mm with 0.4 mm thicknesshaving load carrying capacity of 15 kg/m2. The T sections should have Galvanizing of 120 g/m2 and need to be installed with Suspension systemSqm2036.02036.036.0FalseNoneNoneFalseNoneFalse73296.00
3532508127191NoneCSR 2023-24 Vol-2 P No.43 Item No.8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster meshm35.735.76576.0FalseNoneNoneFalseNoneFalse234763.20
3532509127191NoneCSR 2023-24 Vol-2 P No.65 Item No.9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. GROUND FLOORSqm1521.451521.45307.08FalseNoneNoneFalseNoneFalse467206.8660
17211162020000NoneNoneBuildingsPart-I KKRDB SCP (Work code VNR23S4123152) Demolition of Old CHC Hospital Building At Ujjini Village1064440.69
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3532510127192NoneCSR 2023-24, Item Code 19.3 & Page No-187 Vol-IIDemolishing R.C.C. work manually/ by mechanical means including stack ing of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. Cum2547.32547.3153.48FalseNoneNoneFalseNoneFalse390959.6040
3532511127192NoneCSR 2023-24, Item Code 19.7.3 & Page No-187 Vol-IIDemolishing brick work manually/ by mechanical means including stack ing of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. Cum1080.451080.45141.16FalseNoneNoneFalseNoneFalse152516.3220
3532512127192NoneCSR 2023-24, Item Code 19.9.2 & Page No-187 Vol-IIDemolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineerin-charge.1) In cement mortar Cum1768.21768.2294.63FalseNoneNoneFalseNoneFalse520964.7660
17211162020000NoneNoneBuildingsPart-III KKRDB Gen (Work code VNR23S4123320) INTERNAL ELE WORKS(Gen-25.303)2476066.6
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3532513127193NoneCSR 2023-24 Vol-6 Chapter -2 P No.5 Item No.2.2.1POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switch box Point282.45282.4571.0FalseNoneNoneFalseNoneFalse20053.950
3532514127193NoneCSR 2023-24 Vol-6 Chapter -2 P No.5 Item No.2.2.2Medium point above 3 mts upto 6mts from tapping point to outlet via switch box Point397.5397.580.0FalseNoneNoneFalseNoneFalse31800.00
3532515127193NoneCSR 2023-24 Vol-6 Chapter -2 P No.5 Item No.2.2.3Long point above 6 mts upto 10 mts from tapping point to outlet via switch box Point585.75585.7578.0FalseNoneNoneFalseNoneFalse45688.50
3532516127193NoneCSR 2023-24 Vol-6 Chapter -2 P No.5 Item No.2.2.4Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switches Point710.85710.8549.0FalseNoneNoneFalseNoneFalse34831.650
3532517127193NoneCSR 2023-24 Vol-6 Chapter -2 P No.5 Item No.2.2.5Three outlet in a row above 6 mts upto 10 mts from the tapping point to outlet via switches Point1038.451038.458.0FalseNoneNoneFalseNoneFalse8307.60
3532518127193NoneCSR 2023-24 Vol-6 Chapter -3 P No.8 Item No.3.4.1Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 1 - 2 WayEach144.9144.91.0FalseNoneNoneFalseNoneFalse144.90
3532519127193NoneCSR 2023-24 Vol-6 Chapter -3 P No.8 Item No.3.4.23 WayEach166.95166.958.0FalseNoneNoneFalseNoneFalse1335.60
3532520127193NoneCSR 2023-24 Vol-6 Chapter -3 P No.8 Item No.3.4.34 - 5Way Each185.85185.851.0FalseNoneNoneFalseNoneFalse185.850
3532521127193NoneCSR 2023-24 Vol-6 Chapter -3 P No.8 Item No.3.4.46 Way Each231.0231.01.0FalseNoneNoneFalseNoneFalse231.00
3532522127193NoneCSR 2023-24 Vol-6 Chapter -3 P No.8 Item No.3.4.58 Way Each274.05274.0536.0FalseNoneNoneFalseNoneFalse9865.80
3532523127193NoneCSR 2023-24 Vol-6 Chapter -3 P No.8 Item No.3.4.610 / 12 Way Each334.95334.9575.0FalseNoneNoneFalseNoneFalse25121.250
3532524127193NoneCSR 2023-24 Vol-6 Chapter -3 P No.8 Item No.3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 1 to 2 Module Each143.85143.851.0FalseNoneNoneFalseNoneFalse143.850
3532525127193NoneCSR 2023-24 Vol-6 Chapter -3 P No.8 Item No.3.5.23 Module Each169.05169.058.0FalseNoneNoneFalseNoneFalse1352.40
3532526127193NoneCSR 2023-24 Vol-6 Chapter -3 P No.8 Item No.3.5.34 Module Each183.75183.751.0FalseNoneNoneFalseNoneFalse183.750
3532527127193NoneCSR 2023-24 Vol-6 Chapter -3 P No.8 Item No.3.5.46 Module Each245.7245.71.0FalseNoneNoneFalseNoneFalse245.70
3532528127193NoneCSR 2023-24 Vol-6 Chapter -3 P No.8 Item No.3.5.58 Module Each294.2294.236.0FalseNoneNoneFalseNoneFalse10591.20
3532529127193NoneCSR 2023-24 Vol-6 Chapter -3 P No.8 Item No.3.5.610-12 Module Each361.2361.275.0FalseNoneNoneFalseNoneFalse27090.00
3532530127193NoneCSR 2023-24 Vol-6 Chapter -3 P No.9 Item No.3.6.1Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps one way switch Each107.1107.1490.0FalseNoneNoneFalseNoneFalse52479.00
3532531127193NoneCSR 2023-24 Vol-6 Chapter -3 P No.9 Item No.3.6.36 Amps 3 way sockets Each179.55179.55244.0FalseNoneNoneFalseNoneFalse43810.20
3532532127193NoneCSR 2023-24 Vol-6 Chapter -3 P No.9 Item No.3.6.4stepped fan Regulator Two Module Each374.85374.8557.0FalseNoneNoneFalseNoneFalse21366.450
3532533127193NoneCSR 2023-24 Vol-6 Chapter -3 P No.9 Item No.3.6.106/16 Amps universal sockets Each247.8247.84.0FalseNoneNoneFalseNoneFalse991.20
3532534127193NoneCSR 2023-24 Vol-6 Chapter -3 P No.9 Item No.3.6.716A one way switch Each189.0189.04.0FalseNoneNoneFalseNoneFalse756.00
3532535127193NoneCSR 2023-24 Vol-6 Chapter -3 P No.9 Item No.3.6.932A DP switch Each342.3342.314.0FalseNoneNoneFalseNoneFalse4792.20
3532536127193NoneCSR 2023-24 Vol-6 Chapter -3 P No.9 Item No.3.6.86A Bell push Each185.85185.855.0FalseNoneNoneFalseNoneFalse929.250
3532537127193NoneCSR 2023-24 Vol-6 Chapter -12 P No.48ItemNo.12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Donng bell Each258.3258.35.0FalseNoneNoneFalseNoneFalse1291.50
3532538127193NoneCSR 2023-24 Vol-6 Chapter -13 P No.56 Item No.13.1Extra length of GI pipe of class B 19mm dia for down rod. Each206.85206.8534.0FalseNoneNoneFalseNoneFalse7032.90
3532539127193NoneCSR 2023-24 Vol-6 Chapter -1 P No.4 Item No.1.13Supply and fixing one metal Fan box with round hook Each122.85122.8557.0FalseNoneNoneFalseNoneFalse7002.450
3532540127193NoneCSR 2023-24 Vol-6 Chapter -1 P No.2 Item No.1.2.1Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc.and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 20 mm dia 2mm thickMtr69.369.31100.0FalseNoneNoneFalseNoneFalse76230.00
3532541127193NoneCSR 2023-24 Vol-6 Chapter -1 P No.2 Item No.1.2.225 mm dia 2mm thick Mtr81.981.9800.0FalseNoneNoneFalseNoneFalse65520.00
3532542127193NoneCSR 2023-24 Vol-6 Chapter -1 P No.2 Item No.1.2.332 mm dia 2.5mm thick Mtr108.15108.15350.0FalseNoneNoneFalseNoneFalse37852.50
3532543127193NoneCSR 2023-24 Vol-6 Chapter -1 P No.2 Item No.1.3.1Groove Cutting in Wall Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thick Mtr71.471.4300.0FalseNoneNoneFalseNoneFalse21420.00
3532544127193NoneCSR 2023-24 Vol-6 Chapter -1 P No.2 Item No.1.3.225 mm dia 2mm thick Mtr82.9582.95250.0FalseNoneNoneFalseNoneFalse20737.50
3532545127193NoneCSR 2023-24 Vol-6 Chapter -1 P No.2 Item No.1.3.332 mm dia 2.5mm thick Mtr103.95103.95125.0FalseNoneNoneFalseNoneFalse12993.750
3532546127193NoneCSR 2023-24 Vol-6 Chapter -1 P No.2 Item No.1.5.1Supplying and fixing PVC/metal conduit deep junction box . 19/20mm deep junction box Each51.4551.45130.0FalseNoneNoneFalseNoneFalse6688.50
3532547127193NoneCSR 2023-24 Vol-6 Chapter -1 P No.2 Item No.1.5.225mm deep junction box Each58.858.8100.0FalseNoneNoneFalseNoneFalse5880.00
3532548127193NoneCSR 2023-24 Vol-6 Chapter -1 P No.2 Item No.1.5.332mm deep junction box Each64.0564.0530.0FalseNoneNoneFalseNoneFalse1921.50
3532549127193NoneCSR 2023-24 Vol-6 Chapter -2 P No.5 Item No.2.3.2WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 1.5 Sq.mm Mtr27.327.33200.0FalseNoneNoneFalseNoneFalse87360.00
3532550127193NoneCSR 2023-24 Vol-6 Chapter -2 P No.5 Item No.2.3.32.5 sq.mm Mtr44.144.12400.0FalseNoneNoneFalseNoneFalse105840.00
3532551127193NoneCSR 2023-24 Vol-6 Chapter -2 P No.5 Item No.2.3.44 sq.mm Mtr66.1566.151600.0FalseNoneNoneFalseNoneFalse105840.00
3532552127193NoneCSR 2023-24 Vol-6 Chapter -2 P No.5 Item No.2.3.56sq.mm Mtr96.696.6450.0FalseNoneNoneFalseNoneFalse43470.00
3532553127193NoneCSR 2023-24 Vol-6 Chapter -2 P No.6 Item No.2.3.610sq.mm Mtr175.35175.35150.0FalseNoneNoneFalseNoneFalse26302.50
3532554127193NoneCSR 2023-24 Vol-6 Chapter -2 P No.6 Item No.2.3.716sq.mm Mtr333.0333.0100.0FalseNoneNoneFalseNoneFalse33300.00
3532555127193NoneCSR 2023-24 Vol-6 Chapter -5 P No.18ItemNo.5.19.9Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & N Each2445.452445.454.0FalseNoneNoneFalseNoneFalse9781.80
3532556127193NoneCSR 2023-24 Vol-6 Chapter5P No.18 Item No.5.19.114 Way TP & N Each4239.94239.93.0FalseNoneNoneFalseNoneFalse12719.70
3532557127193NoneCSR 2023-24 Vol-6 Chapter 5P No.18 Item No.5.19.126 Way TP & N Each5187.05187.03.0FalseNoneNoneFalseNoneFalse15561.00
3532558127193NoneCSR 2023-24 Vol-6 Chapter5 P No.18 Item No.5.19.138 Way TP & N Each6395.556395.552.0FalseNoneNoneFalseNoneFalse12791.10
3532559127193NoneCSR 2023-24 Vol-6 Chapter5 P No.17 Item No.5.17.3Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 12 Way Each16305.4516305.451.0FalseNoneNoneFalseNoneFalse16305.450
3532560127193NoneCSR 2023-24 Vol-6 Chapter -5 P No.17 ItemNo.5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP Each435.75435.7560.0FalseNoneNoneFalseNoneFalse26145.00
3532561127193NoneCSR 2023-24 Vol-6 Chapter -5 P No.17 ItemNo.5.18.540 A DP Each1113.01113.024.0FalseNoneNoneFalseNoneFalse26712.00
3532562127193NoneCSR 2023-24 Vol-6 Chapter -5 P No.18 ItemNo.5.18.950-63 A TPN Each3242.43242.412.0FalseNoneNoneFalseNoneFalse38908.80
3532563127193NoneCSR 2023-24 Vol-6 Chapter -5 P No.18 ItemNo.5.20.4Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board. 32-40Amps 2 pole Each4786.954786.959.0FalseNoneNoneFalseNoneFalse43082.550
3532564127193NoneCSR 2023-24 Vol-6 Chapter -5 P No.18ItemNo.5.20.1063Amps 4 pole Each5822.05822.03.0FalseNoneNoneFalseNoneFalse17466.00
3532565127193NoneCSR 2023-24 Vol-6 Chapter -5 P No.14 Item No.5.5.2Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour." 63AEach4193.934193.934.0FalseNoneNoneFalseNoneFalse16775.720
3532566127193NoneCSR 2023-24 Vol-6 Chapter -11Item No.12.59.2Supply & installation of 300 mm wide & 40mm height, 1.6 mm thick Perfforated cable trays fixed with MS supports,anchor bolt etc.,complete as required at site. 300 x 50 mmMtr616.35616.3525.0FalseNoneNoneFalseNoneFalse15408.750
3532567127193NoneCSR 2023-24 Vol-6 Chapter1 P No.56 Item No.12.59.1Supply & installation of 150 mm wide & 40mm height, 1.6 mm thick Perfforated cable trays fixed with MS supports,anchor bolt etc.,complete as required at site. Mtr486.15486.1525.0FalseNoneNoneFalseNoneFalse12153.750
3532568127193NoneCSR 2023-24 Vol-6 Chapter -11 PNo.43 ItemNo.12.3.2LED light fitting 1 x 4' - 20/22 W Each724.5724.5144.0FalseNoneNoneFalseNoneFalse104328.00
3532569127193NoneCSR 2023-24 Vol-6 Chapter -11P No.44Item No.11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with . W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12WEach929.25929.2528.0FalseNoneNoneFalseNoneFalse26019.00
3532570127193NoneCSR 2023-24 Vol-6 Chapter -11 P No.44ItemNo.11.5.3LED square or round down light 15-18W Each1390.21390.215.0FalseNoneNoneFalseNoneFalse20853.00
3532571127193NoneCSR 2023-24 Vol-6 Chapter -11 PNo.45 ItemNo.11.6.3Supplying of recess mounting non integral type . LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per W, 120degree beam spread, life25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2'-34-36W No4780.654780.657.0FalseNoneNoneFalseNoneFalse33464.550
3532572127193NoneCSR 2023-24 Vol-6 Chapter -6 P No.30 Item No.6.1Supplying exhaust fan of 1440 RPM of 300 mm (12"") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. Each1566.61566.617.0FalseNoneNoneFalseNoneFalse26632.20
3532573127193NoneCSR 2023-24 Vol-6 Chapter -6 P No.30 Item No.6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty. 48" Sweep 5 Star (1200 mm) Each3133.23133.257.0FalseNoneNoneFalseNoneFalse178592.40
3532574127193NoneCSR 2023-24 Vol-6 Chapter-13PNo.56 Item No.13.7.1Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.Each128.1128.1144.0FalseNoneNoneFalseNoneFalse18446.40
3532575127193NoneCSR 2023-24 Vol-6 Chapter-13 P No.57 Item No.13.10Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each179.55179.5557.0FalseNoneNoneFalseNoneFalse10234.350
3532576127193NoneCSR 2023-24 Vol-6 Chapter-13 P No.57 ItemNo.13.13Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.ofapproved make with wire mesh and wooden frame.Each742.35742.3517.0FalseNoneNoneFalseNoneFalse12619.950
3532577127193NoneCSR 2023-24 Vol-6 Chapter-2 P No.6 Item No.2.5.8Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 2.5 sqmm Mtr118.65118.65100.0FalseNoneNoneFalseNoneFalse11865.00
3532578127193NoneCSR 2023-24 Vol-6 Chapter-2 P No.6 Item No.2.5.153C x 4 sqmm Mtr180.6180.6100.0FalseNoneNoneFalseNoneFalse18060.00
3532579127193NoneCSR 2023-24 Vol-6 Chapter-11 PNo.45 Item No.11.7.2Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light outputRated life Burning Hrs 50000 hr@ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/1 EC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Post Top Lantern with 25/30 Watts.Each8108.18108.12.0FalseNoneNoneFalseNoneFalse16216.20
3532580127193NoneCSR 2023-24 Vol-6 Chapter-5P No.20Item No.5.40.2Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 30 x 10 mm Aluminium Strips Mtr3606.753606.756.5FalseNoneNoneFalseNoneFalse23443.8750
3532581127193NoneCSR 2023-24 Vol-6 Chapter-5 P No.20 Item No.5.41.2Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. Flat.with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 50 x 50 x 6 mm Mtr414.75414.759.0FalseNoneNoneFalseNoneFalse3732.750
3532582127193NoneCSR 2023-24 Vol-6 Chapter-5 P No.17 Item No.5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-circuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR Pole Incomers 100A25KA Each8911.358911.351.0FalseNoneNoneFalseNoneFalse8911.350
3532583127193NoneCSR 2023-24 Vol-6 Chapter-5 P No.17 ItemNo.5.15.16400 A 36 kA Each29626.829626.81.0FalseNoneNoneFalseNoneFalse29626.80
3532584127193NoneCSR 2023-24 Vol-6 Chapter-5 P No.18 Item No.5.18.9Out Goings Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN Each3242.43242.46.0FalseNoneNoneFalseNoneFalse19454.40
3532585127193NoneCSR 2023-24 Vol-6 Chapter-5 P No.17Item No.5.18.540 A DP Each1113.01113.04.0FalseNoneNoneFalseNoneFalse4452.00
3532586127193NoneCSR 2023-24 Vol-6 Chapter-5 P No.19 Item No.5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. Each540.75540.753.0FalseNoneNoneFalseNoneFalse1622.250
3532587127193NoneCSR 2023-24 Vol-6 Chapter-5 P No.18 Item No.5.22Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board. Each474.6474.61.0FalseNoneNoneFalseNoneFalse474.60
3532588127193NoneCSR 2023-24 Vol-6 Chapter-5 P No.18 Item No.5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. Each9717.759717.751.0FalseNoneNoneFalseNoneFalse9717.750
3532589127193NoneCSR 2023-24 Vol-6 Chapter-5 P No.18 Item No.5.26Supplying, fixing and wiring 0 to 1500A CT operated AC analog type Ammeter without CT Each504.0504.03.0FalseNoneNoneFalseNoneFalse1512.00
3532590127193NoneCSR 2023-24 Vol-6 Chapter-5 P No.19 Item No.5.27Supplying, fixing and wiring rotary selector switch suitable for Ammeter Each210.0210.01.0FalseNoneNoneFalseNoneFalse210.00
3532591127193NoneCSR 2023-24 Vol-6 Chapter-5 P No.19 Item No.5.28Supplying, fixing and wiring rotary selector switch suitable for Voltmeter Each168.0168.01.0FalseNoneNoneFalseNoneFalse168.00
3532592127193NoneCSR 2023-24 Vol-6 Chapter-5 P No.19 Item No.5.29Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter Each1496.251496.251.0FalseNoneNoneFalseNoneFalse1496.250
3532593127193NoneCSR 2023-24 Vol-6 Chapter-2 P No.5 Item No.2.3.2WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multi strand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2 Mtr27.327.325.0FalseNoneNoneFalseNoneFalse682.50
3532594127193NoneCSR 2023-24 Vol-6 Chapter-2 P No.5 Item No.2.3.32.5 mm2 Mtr44.144.120.0FalseNoneNoneFalseNoneFalse882.00
3532595127193NoneCSR 2023-24 Vol-6 Chapter-5 P No.20 ItemNo.5.42.2PANEL.1 Fabricating supplying and mounting MS box made out .SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG Sq CM0.450.4590000.0FalseNoneNoneFalseNoneFalse40500.00
3532596127193NoneCSR 2023-24 Vol-6 Chapter-5 P No.20Item No.5.40.2Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 30 x 10 mm Aluminium Strips Mtr3606.753606.755.0FalseNoneNoneFalseNoneFalse18033.750
3532597127193NoneCSR 2023-24 Vol-6 Chapter-5 P No.20 Item No.5.41.2Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. Flat.with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mm Mtr414.75414.7512.0FalseNoneNoneFalseNoneFalse4977.00
3532598127193NoneCSR 2023-24 Vol-6 Chapter5P No.17 Item No.5.15.15Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR Pole Incomers 250 A 36 kA Each24722.2524722.251.0FalseNoneNoneFalseNoneFalse24722.250
3532599127193NoneCSR 2023-24 Vol-6 Chapter-5 P No.18 Item No.5.18.9Out Goings Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN Each3242.43242.410.0FalseNoneNoneFalseNoneFalse32424.00
3532600127193NoneCSR 2023-24 Vol-6 Chapter-5 P No.17Item No.5.18.540 A DP Each1113.01113.06.0FalseNoneNoneFalseNoneFalse6678.00
3532601127193NoneCSR 2023-24 Vol-6 Chapter-5 P No.17 ItemNo.5.15.11160 A 25 kA Each14119.3514119.352.0FalseNoneNoneFalseNoneFalse28238.70
3532602127193NoneCSR 2023-24 Vol-6 Chapter-5 P No.17 ItemNo.5.15.17125 A 25 kA Each10858.0510858.052.0FalseNoneNoneFalseNoneFalse21716.10
3532603127193NoneCSR 2023-24 Vol-6 Chapter-5 P No.19 Item No.5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. Each540.75540.753.0FalseNoneNoneFalseNoneFalse1622.250
3532604127193NoneCSR 2023-24 Vol-6 Chapter-5 P No.18 Item No.5.22Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board Each474.6474.61.0FalseNoneNoneFalseNoneFalse474.60
3532605127193NoneCSR 2023-24 Vol-6 Chapter-5 P No.18 Item No.5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each9717.759717.751.0FalseNoneNoneFalseNoneFalse9717.750
3532606127193NoneCSR 2023-24 Vol-6 Chapter-5 P No.18 Item No.5.26Supplying, fixing and wiring 0 to 1500A CT operated AC analog type Ammeter without CT Each504.0504.03.0FalseNoneNoneFalseNoneFalse1512.00
3532607127193NoneCSR 2023-24 Vol-6 Chapter-5 P No.19 Item No.5.27Supplying, fixing and wiring rotary selector switch suitable for Ammeter Each210.0210.01.0FalseNoneNoneFalseNoneFalse210.00
3532608127193NoneCSR 2023-24 Vol-6 Chapter-5 P No.19 Item No.5.28Supplying, fixing and wiring rotary selector switch suitable for Voltmeter Each168.0168.01.0FalseNoneNoneFalseNoneFalse168.00
3532609127193NoneCSR 2023-24 Vol-6 Chapter-5 P No.19 Item No.5.29Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter Each1496.251496.251.0FalseNoneNoneFalseNoneFalse1496.250
3532610127193NoneCSR 2023-24 Vol-6 Chapter-2 P No.5 Item No.2.3.2WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multi strand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2 Mtr27.327.325.0FalseNoneNoneFalseNoneFalse682.50
3532611127193NoneCSR 2023-24 Vol-6 Chapter-2 P No.5 Item No.2.3.32.5 mm2 Mtr44.144.120.0FalseNoneNoneFalseNoneFalse882.00
3532612127193NoneCSR 2023-24 Vol-6 Chapter-5 P No.20 ItemNo.5.42.2PANEL.2 Fabricating supplying and mounting MS box made out .SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG Sq CM0.450.4590000.0FalseNoneNoneFalseNoneFalse40500.00
3532613127193NoneCSR 2023-24 Vol-6 Chapter-5 P No.20 Item No.5.40.2Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 30 x 6mm Aluminium Strips Mtr3606.753606.755.0FalseNoneNoneFalseNoneFalse18033.750
3532614127193NoneCSR 2023-24 Vol-6 Chapter-5 PNo.20 Item No.5.41.1Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. Flat.with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mm Mtr414.75414.7512.0FalseNoneNoneFalseNoneFalse4977.00
3532615127193NoneCSR 2023-24 Vol-6 Chapter-5 P No.17 ItemNo.5.15.17Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-circuit/Over Load. For Microprocessor MCCB Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR Pole Incomers 250 A 36 kA Each24722.2524722.251.0FalseNoneNoneFalseNoneFalse24722.250
3532616127193NoneCSR 2023-24 Vol-6 Chapter-5 PNo.18 Item No.5.18.9Out Goings Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN Each3242.43242.45.0FalseNoneNoneFalseNoneFalse16212.00
3532617127193NoneCSR 2023-24 Vol-6 Chapter-5 P No.17 ItemNo.5.18.540 A DP Each1113.01113.03.0FalseNoneNoneFalseNoneFalse3339.00
3532618127193NoneCSR 2023-24 Vol-6 Chapter-5 P No.17 ItemNo.5.15.16160 A 25 kA Each14119.3514119.351.0FalseNoneNoneFalseNoneFalse14119.350
3532619127193NoneCSR 2023-24 Vol-6 Chapter-5 P No.17 ItemNo.5.15.10125 A 25 kA Each10858.0510858.052.0FalseNoneNoneFalseNoneFalse21716.10
3532620127193NoneCSR 2023-24 Vol-6 Chapter-5 P No.19 Item No.5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. Each540.75540.753.0FalseNoneNoneFalseNoneFalse1622.250
3532621127193NoneCSR 2023-24 Vol-6 Chapter-5 P No.17 ItemNo.5.15.10125A25 kA Each10858.0510858.052.0FalseNoneNoneFalseNoneFalse21716.10
3532622127193NoneCSR 2023-24 Vol-6 Chapter-6 P No.32 Item No.6.12InstallationchargesforsplittypeairconditionerwithalliedworksforoneindoorandoneoutdoorunitistobemountedonsuitableAngleIron support upto 3.0 Ton split/cassette type A/C. Each3333.753333.753.0FalseNoneNoneFalseNoneFalse10001.250
3532623127193NoneCSR 2023-24 Vol-6 Chapter-6 P No.32 Item No.6.22ExtraforFabricationsupplyandfixingofStandfabricatedusingslottedangle/Langleofsize6mmx50mmformountingoutdoor/indoor A.C. unit/ Batteries. Each5047.355047.353.0FalseNoneNoneFalseNoneFalse15142.050
3532624127193NoneCOMMON SR 2023-24, Vol-6, I No. 9.1.2, P.No - 38Supplying,erecting,testingandcommissioningofvoltagestabilizersuitablefor170to270vinputandloadvariationfromnoloadtofullload,withoverloadprotection,spikesuppression,operatingat00Cto 400 C. Range etc., complete. 4kVA Capacity Each5031.65031.62.0FalseNoneNoneFalseNoneFalse10063.20
3532625127193NoneCOMMON SR 2023-24, Vol-6, I No.9.1.3 P.No - 38Supplying,erecting,testingandcommissioningofvoltagestabilizersuitablefor170to270vinputandloadvariationfromnoloadtofullload,withoverloadprotection,spikesuppression,operatingat00Cto 400 C. Range etc., complete. 5kVA Capacity Each10149.310149.31.0FalseNoneNoneFalseNoneFalse10149.30
3532626127193NoneCOMMON SR 2023-24, Vol-6, I No. 5.31, P.No - 19SupplyingandfixingElectronicTrivectorMeter(ETV)suitableforoperationLToperationandCToperatedmeterinpolycarbonatebodyinclass0.5accuracyasperIS14697andcompletely wired. Each4609.54609.51.0FalseNoneNoneFalseNoneFalse4609.50
3532627127193NoneCOMMON SR 2023-24, Vol-6, I No. 5.32, P.No - 19Supplyingandfixingdigitalfrequencymeterwithlatestmicrocontrollertechnology,ultrabright4digitLEDdisplay,from30,500VACandoptionalorrelayoutputforhigh/lowfrequencyandwiringcomplete. Each1023.751023.751.0FalseNoneNoneFalseNoneFalse1023.750
3532628127193NoneCSR 2023-24 Vol-6 Chapter-5 P No.19 Item No.5.33SupplyingofmultifunctiondigitalmeterwiththreelinebacklightLCDtypedisplayforvoltage,Current,frequency,Power,powerfactor,kVA,kWH,kVARsuitablefor3phase,4wireLTnetworkwithIP54degreeofprotectionandcompletelywiredasrequiredwithcommunication Port and Class 0.5s accuracy Each9780.759780.751.0FalseNoneNoneFalseNoneFalse9780.750
3532629127193NoneCOMMON SR 2023-24, Vol-6, I No. 11.8.5, P.No - 45SupplyofLEDStreetlightluminairewithpressurediecastaluminiumhousingbodyforoptimalthermaldissipation.LampcompartmentcomprisingofantiglarecleardiffuserwithInjectionmouldedpolycarbonatematerial,deliveringsuperiorlightoutputRatedlifeBurningHrs50000hr@LumenMaintenanceof70%,maximumlightintensityshouldbebetween60degreesto70degrees.CCT5500K,IP66opticalandelectricalcompartment&impactresistanceofcompleteluminaireIK08.PowerFactor0.9withmains,SurgeProtection-Min5KValongwithOvervoltage/Overload,shortcircuit/miss-wiringprotection.Compatibleforpolemountingwithouterdiaof40mmto50mm.UniversalVoltagedrivertooperatewidevoltagerangefrom100Vto270V50/60Hzapplication.CompliancetoIS10322/IEC60598,LM79&LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light withsinglescrewtoensureeaseofmaintenanceatthesightsitelocationwithminimizedminimaltools.LEDLightfixturewith.WSystemPowerconsumption.LEDEfficiency1301m/w,nominalCRI75.LuminairemanufacturershouldhaveinhousefacilityaccreditedbyNABL/CPRI&anyGovernmentcertifiedagency&Design&DevelopmentfacilitycertifiedbyISO9001:2008.Housingwithsupplierwordmark/nameshallbeEngraved/Embossingonthediecasthousing/Bodypart.Warrantyof2YearsagainstanymanufacturingdefectworkingunderstandardelectricalconditionsasmentionedaboveshouldbegivenbyLEDmanufactrer&Cree/Nichia/Lumileds/Osram make LED Source LED Streetlight 120 W Each10563.010563.010.0FalseNoneNoneFalseNoneFalse105630.00
3532630127193NoneCOMMON SR 2023-24, Vol-6, I No. 11.11.7, P.No - 47Supplying&fixingofretrofittypeLEDbulb.WwithOPALacrylicdiffusercomprisingofLEDsourcewithCCT6500degreeK,CRI70%.efficacy80lumenperW,life25000burninghoursandCompliancetoIS10322/IEC60598,LM79&LM80.TheLEDaredrivenbyHFelectronicdriverintegratedinthesystem,withPF.95,powerlossshould5%oflampWage.,shortcircuit&opencircuitprotectiontobeintegratedinthecircuit,THDlessthan20%,LifeasperLM79.Theoperatinginputvoltageshouldbebetween130to275V.BISApprovedandTestedbyNABL/CPRIaccreditedlaboratorywith2yearsWarrantyag 18W, 6500K Each447.3447.323.0FalseNoneNoneFalseNoneFalse10287.90
3532631127193NoneCOMMON SR 2023-24, Vol-6, I No. 12.2.1, P.No - 48Supplyingandfixingoneof230VDingdongbellandaflushtypebellpushwithgangboxfixedonnecessarywoodenorrawlplugsusingNFscrews with Remote. Each258.3258.35.0FalseNoneNoneFalseNoneFalse1291.50
3532632127193NoneCOMMON SR 2023-24, Vol-6, I No. 13.2.3, P.No - 56SupplyingandFixing.mmdiaclampsssAGIpipebracketupto2.7meterslongterminatedwithareducingcollarof40x25mmtowhichextrapipeof175mmlengthisfixedforfixingV/SV/MH/FTLstreetlightfittingofallcapacitiesonrail/RCC/wall/tubularpole,usingsuitableclamps,bolts,nutsandwiringusingsuitablecapacitywires. 40mm dia G.I Pipe Each1551.91551.910.0FalseNoneNoneFalseNoneFalse15519.00
3532633127193NoneCOMMON SR 2023-24, Vol-6, I No. 13.5, P.No - 56Fixinghalogen/metalhalide/SVL/IL/LEDfloodlightfittingoverexistingpole/wallceilingincludingclamps,bolts,nutsandwiringusing suitable capacity wires. Each207.9207.910.0FalseNoneNoneFalseNoneFalse2079.00
3532634127193NoneCSR 2023-24 Vol-6 Chapter-5 PNo.20 Item No.5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 16 SWG Sq CM0.450.4590000.0FalseNoneNoneFalseNoneFalse40500.00
3532635127193NoneCSR 2023-24 Vol-6 Chapter-2 P No.6 Item No.2.3.716 mm2 Mtr333.9333.925.0FalseNoneNoneFalseNoneFalse8347.50
3532636127193NoneCSR 2023-24 Vol-6 Chapter-5 P No.17 ItemNo.5.15.16160 A 25kA Each14119.3514119.351.0FalseNoneNoneFalseNoneFalse14119.350
17211162020000NoneNoneBuildingsPart-IV KKRDB SDP (Work code VNR23S4123421) FIRE FIGHTING WORKS73150.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3532637127194NoneCSR 2023-24 Vol-6 P No.72 Item No.15.3Supply and installation of 2 Kg C02 Gas Type Fire Extinugisher Squeeze grip type, used Unused Mechanism, Squeeze Grip, Gross Weight 9.1 Kg. empty Weight 7.1 Kg. Can Height 595MM Diameter 108MM, Discharge Time less than 8 Sees, Controllable discharge mechanism, Applicable on Class 8&C Fire, 8 Rating 88, Can Construction : Hot spinning/Forging, Valve Construction : Forging & Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Sheet metal thickness: 4.0MM lSI Approved, 1 Year Warranty.with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost cost of supporting materials like MS stand & accessaries if it is fixing n floor / MS brackets & accessories if it is fixing on wall, labour, usage charges of machinery complete as per specifications. complete Nos5500.05500.02.0FalseNoneNoneFalseNoneFalse11000.00
3532638127194NoneCSR 2023-24 Vol-6 P No.75 Item No.15.42Providing Water type- 9 Ltr -Stored Pressure Supply and installation of 9 Ltr Water type Fire Extinugisher, Stored Pressure Type, Pressur Gauge, Gross Weight 15.1kg. empty weight 6.1kg Can Height 615MM, Diameter 175 MM, Discharge Time less than 120 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 6 Meters, applicable on Class A Fire, A Rating 3A, Can Construction; Deep drawn & CO, Mig welded, Valve Construction: Forging & Machining, Internal Coating of Can : Epoxy Powder coating, External Coating of Can : Epoxy Polyster Powder coating, Sheet metal thickness: 2.OM M, lS 15683 and CE Approved. Years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost cost of supporting materials like MS stand & accessaries if it is fixing n floor / MS brackets & accessories if it is fixing on wall, labour, usage charges of machinery complete as per specifications. complete Nos9100.09100.02.0FalseNoneNoneFalseNoneFalse18200.00
3532639127194NoneCSR 2023-24 Vol-6 P No.61 Item No.15.2Providing ABC Powder based MAP 50, 2Kg Supply and installation of 2kg Fire Extinguisher Mono Ammonium Phosphate Powder 50, Stored Pressure Type, Pressure Gauge, Gross Weight 3.6 Kg, empty weight 1.6 Kg, Can Height 344MM, Diameter 108MM, Discharge Time less than 8 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 2 meters, applicable on Class A,8, C and electrically started Fire, A Rating 1A, 8 Rating 88, Can construction : Deep drawn & Co. , Mig welded, valve Construciton: Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy PoIyster power coating, Sheet metal thickness: 1.60MM, 5 years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost cost of supporting materials like MS stand & accessaries if it is fixing n floor / MS brackets & accessories if it is fixing on wall, labour, usage charges of machinery complete as per specifications. complete. IS 15683, CE A 5 with Nos2100.02100.010.0FalseNoneNoneFalseNoneFalse21000.00
3532640127194NoneCSR 2023-24 Vol-6 P No.62 Item No.15.4Providing ABC Powder based MAP 50, 6Kg Supply and installation in position, testing and commissioning 6kg Fir e Ex tinguisher Mono Ammonium Phos phate Powder 50, Stored Pressure Type, Pressure Gauge, Gross Weight 9.5 Kg, empty weight 3.5 Kg, Can Height 435MM, Diameter 160MM, Discharge Time less than 9 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 4 meters, applicable on Class A,8,C and electrically started Fire, A Rating 3A, 8 Rating 218, Can construction : Deep drawn & Co., Mig welded, valve Construciton : Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy PoIyster power coating, Sheet metal thickness: 1.60MM, 5 years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost cost of supporting materials like MS stand & accessaries if it is fixing n floor / MS brackets & accessories if it is fixing on wall, labour, usage charges of machinery complete as per specificed.with regards to general guidelines of fire saf Nos2850.02850.05.0FalseNoneNoneFalseNoneFalse14250.00
3532641127194NoneCSR 2023-24 Vol-6 P No.68 Item No.15.22Providing 2Kg Fire Extinguisher Clean Agent HCFC 123 Supply and installation of 2Kg Pressure type, Pressure Guage, Gross Weight 3.7Kg, empty weight 1.7 Kg, Can Height 344MM, Diameter 108MM, Discharge Time less than 8 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 2 meters, applicable on Class A,8,C and electrically started Fire, 8 Rating 218, Can construction: Deep drawn &Co., Mig welded, valve Construciton: Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy PoIyster power coating, Sheet metal thickness: 2.00 MM, 5 years warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost cost of supporting materials like MS stand & accessaries if it is fixing n floor / MS brackets & accessories if it is fixing on wall, labour, usage charges of machinery complete as per specifications. complete IS15683 and CE Approved. Nos6500.06500.01.0FalseNoneNoneFalseNoneFalse6500.00
3532642127194NoneCSR 2023-24 Vol-6 P No.93 Item No.15.112Supplying of two bucket stand alongwith buckets. complete Set1100.01100.02.0FalseNoneNoneFalseNoneFalse2200.00
17211162020001NoneNoneBuildingsPart-IV KKRDB SDP (Work code VNR23S4123421) SUMP TANK374353.26
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3532643127195NoneCSR 2023-24 Vol-3 P No.9 Item No.2.5(ii)AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle In area of light jungle Clearing & Grubbing 100 Sqm412.65412.650.46FalseNoneNoneFalseNoneFalse189.8190
3532644127195NoneCSR 2023-24 Vol-1 P No.8 Item No.1.14.1EXCAVATION Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth Cum107.1107.132.48FalseNoneNoneFalseNoneFalse3478.6080
3532645127195NoneCSR 2023-24 Vol-1 P No.15 Item No.2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate ibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other ppurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates Cum6288.456288.453.39FalseNoneNoneFalseNoneFalse21317.84550
3532646127195NoneCSR 2023-24 Vol-1 P No.17 Item No.2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Cum6804.06804.017.21FalseNoneNoneFalseNoneFalse117096.840
3532647127195NoneCSR 2023-24 Vol-1 P No.112 Item No.11Form Work and Centering (Addendum Vol1, Page No -111) ( On Finished Rate of Concrete per cum) Earth retaining structures ( 10 % RCC WALl Cum680.4680.46.81FalseNoneNoneFalseNoneFalse4633.5240
3532648127195NoneCSR 2023-24 Vol-1 P No.112 Item No.15RCC Roof Slabs (50%) Roof Slab Concrete Quantity Cum3402.03402.010.4FalseNoneNoneFalseNoneFalse35380.80
3532649127195NoneCSR 2023-24 Vol-1 P No.18 Item No.2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) t93929.093929.01.46FalseNoneNoneFalseNoneFalse137136.340
3532650127195NoneCSR 2023-24 Vol-2 P No.150 Item No.15.5Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethylene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of 25 MPa (as per ASTM D 412), elongation of 500% (as per ASTM D 412), puncture resistance of 1000N (as per ASTM E 154), peel adhesion to concrete 1200N/m (as per ASTM D 903), hydrostatic head resistance 70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and traffic able granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. Sqm635.25635.2553.0FalseNoneNoneFalseNoneFalse33668.250
3532651127195NoneCSR 2023-24 Vol-2 P No.42 Item No.8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm339.15339.1563.25FalseNoneNoneFalseNoneFalse21451.23750
17211162020000NoneNoneBuildingsPart-IV KKRDB SDP (Work code VNR23S4123421)WATER SUPPLY & SANITARY WORKS679862.7
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3532652127196NoneCSR 2023-24 Vol-2 P No.131 Item No.14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid Each6275.856275.8516.0FalseNoneNoneFalseNoneFalse100413.60
3532653127196NoneCSR 2023-24 Vol-2 P No.131 Item No.14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern Each4676.74676.72.0FalseNoneNoneFalseNoneFalse9353.40
3532654127196NoneCSR 2023-24 Vol-2 P No.136 Item No.14.34.1Providing and fixing toilet paper holder : C.P. brass Toilet Paper Holder Each638.4638.416.0FalseNoneNoneFalseNoneFalse10214.40
3532655127196NoneCSR 2023-24 Vol-2 P No.119 Item No.13.12Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 Nos666.75666.7516.0FalseNoneNoneFalseNoneFalse10668.00
3532656127196NoneCSR 2023-24 Vol-2 P No.70 Item No.10.8Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. Sqm2928.452928.451.44FalseNoneNoneFalseNoneFalse4216.9680
3532657127196NoneCSR 2023-24 Vol-2 P No.132 Item No.14.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap" Each2689.052689.056.0FalseNoneNoneFalseNoneFalse16134.30
3532658127196NoneCSR 2023-24 Vol-2 P No.134 Item No.14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Nos5336.15336.12.0FalseNoneNoneFalseNoneFalse10672.20
3532659127196NoneCSR 2023-24 Vol-2 P No.137 Item No.14.40.2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g." Each520.8520.816.0FalseNoneNoneFalseNoneFalse8332.80
3532660127196NoneCSR 2023-24 Vol-2 P No.120 Item No.13.22.2Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid Nos212.1212.128.0FalseNoneNoneFalseNoneFalse5938.80
3532661127196NoneCSR 2023-24 Vol-2 P No.135 Item No14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. Nos850.5850.516.0FalseNoneNoneFalseNoneFalse13608.00
3532662127196NoneCSR 2023-24 Vol-2 P No.136 Item No14.32.2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Each1068.91068.914.0FalseNoneNoneFalseNoneFalse14964.60
3532663127196NoneCSR 2023-24 Vol-2 P No.118 Item No.13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter Nos292.95292.952.0FalseNoneNoneFalseNoneFalse585.90
3532664127196NoneCSR 2023-24 Vol-2 P No.135 Item No.14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. Nos5840.15840.12.0FalseNoneNoneFalseNoneFalse11680.20
3532665127196NoneCSR 2023-24 Vol-2 P No.136 Item No.14.29Providing and fixing 100 mm sand cast Iron grating for gully trap. Iron grating for gully trap GROUND FLOOR Each49.3549.3520.0FalseNoneNoneFalseNoneFalse987.00
3532666127196NoneCSR 2023-24 Vol-2 P No.136 Item No.14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines Each96.696.616.0FalseNoneNoneFalseNoneFalse1545.60
3532667127196NoneCSR 2023-24 Vol-2 P No.128 Item No.13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipes" m303.45303.4540.0FalseNoneNoneFalseNoneFalse12138.00
3532668127196NoneCSR 2023-24 Vol-2 P No.128 Item No.13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipes" m385.0385.069.0FalseNoneNoneFalseNoneFalse26565.00
3532669127196NoneCSR 2023-24 Vol-2 P No.125 Item No.13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter m305.55305.5535.1FalseNoneNoneFalseNoneFalse10724.8050
3532670127196NoneCSR 2023-24 Vol-2 P No.122 Item No.13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." m397.95397.9564.0FalseNoneNoneFalseNoneFalse25468.80
3532671127196NoneCSR 2023-24 Vol-2 P No.122 Item No.13.32.325 mm nominal dia pipes Cold Water Supply GROUND FLOOR m500.85500.8558.0FalseNoneNoneFalseNoneFalse29049.30
3532672127196NoneCSR 2023-24 Vol-2 P No.122 Item No.13.32.432 mm nominal dia pipes Cold Water Supply GROUND FLOOR m584.85584.857.0FalseNoneNoneFalseNoneFalse4093.950
3532673127196NoneCSR 2023-24 Vol-2 P No.123 Item No.13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. External work - Exposed on wall 40 mm nominal dia Pipes" m500.85500.8529.0FalseNoneNoneFalseNoneFalse14524.650
3532674127196NoneCSR 2023-24 Vol-2 P No.123 Item No.13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. External work - Exposed on wall 40 mm nominal dia Pipes TERRACE FLOOR m510.87510.87190.0FalseNoneNoneFalseNoneFalse97065.30
3532675127196NoneCSR 2023-24 Vol-2 P No.136 Item No.14.31Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Nos1281.01281.06.0FalseNoneNoneFalseNoneFalse7686.00
3532676127196NoneCSR 2023-24 Vol-2 P No.123 Item No.13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Ltr9.649.6410000.0FalseNoneNoneFalseNoneFalse96400.00
3532677127196NoneCSR 2023-24 Vol-2 P No.121 Item No.13.26Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mmProviding and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g. Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g. with concealed fitting arrangements, weighing not less than 106 g. Nos105.0105.016.0FalseNoneNoneFalseNoneFalse1680.00
3532678127196NoneCSR 2023-24 Vol-2 P No.117 Item No.13.5.3Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : Nos355.57355.571.0FalseNoneNoneFalseNoneFalse355.570
3532679127196NoneCSR 2023-24 Vol-2 P No.118 Item No.13.6.3.1Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore Horizontal" Nos1028.161028.164.0FalseNoneNoneFalseNoneFalse4112.640
3532680127196NoneCSR 2023-24 Vol-2 P No.133 Item No.11.15.5Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. Nos1606.51606.515.0FalseNoneNoneFalseNoneFalse24097.50
3532681127196NoneCSR 2023-24 Vol-5 P No.133 Item No.11.15.6For 50 mm dia GM (Copper alloy) Gate valves Nos1807.851807.852.0FalseNoneNoneFalseNoneFalse3615.70
3532682127196NoneCSR 2023-24 Vol-5 P No.86 Item No.7.5.1Supplying and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest amendments, in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete Nos1692.181692.184.0FalseNoneNoneFalseNoneFalse6768.720
3532683127196NoneCSR 2023-24 Vol-2 P No.123 Item No.13.37Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. Nos328.65328.6530.0FalseNoneNoneFalseNoneFalse9859.50
3532684127196NoneCSR 2023-24 Vol-2 P No.126 Item No.13.53Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 Ch5924.15924.110.0FalseNoneNoneFalseNoneFalse59241.00
3532685127196NoneCSR 2023-24 Vol-2 P No.124 Item No.13.39Providing and fixing square-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size P-type with Non modular common burnt clay bricks of designation 3.5 & with water tight CI. cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. Nos2710.052710.0510.0FalseNoneNoneFalseNoneFalse27100.50
17211162020001NoneNoneBuildingsPart-IV KKRDB SDP (Work code VNR23S4123421) Septic Tank326862.71
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3532686127197NoneCSR 2023-24 Vol-3 P No.9 Item No.2.5 ii)AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle" Sqm412.65412.650.17FalseNoneNoneFalseNoneFalse70.15050
3532687127197NoneCSR 2023-24 Vol-1 P No.8 Item No.1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m Cum107.1107.142.07FalseNoneNoneFalseNoneFalse4505.6970
3532688127197NoneCSR 2023-24 Vol-1 P No.15 Item No.2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Cum6288.456288.451.16FalseNoneNoneFalseNoneFalse7294.6020
3532689127197NoneCSR 2023-24 Vol-1 P No.16 Item No.2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Cum6804.06804.010.61FalseNoneNoneFalseNoneFalse72190.440
3532690127197NoneCSR 2023-24 Vol-1 P No.112 Item No.11Form Work and Centering Addendum - Vol-1, Page No -111) (PERCENT On Finished Rate of Concrete per CUM Earth retaining structures ( 10% ) Cum680.4680.47.47FalseNoneNoneFalseNoneFalse5082.5880
3532691127197NoneCSR 2023-24 Vol-1 P No.112 Item No.15RCC Roof Slabs (50%) Roof Slab Concrete Quantity Cum3402.03402.03.14FalseNoneNoneFalseNoneFalse10682.280
3532692127197NoneCSR 2023-24 Vol-1 P No.18 Item No.2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) t93929.8593929.851.44FalseNoneNoneFalseNoneFalse135258.9840
3532693127197NoneCSR 2023-24 Vol-2 P No.150 Item No.15.5Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of GREATER THAN 25 MPa (as per ASTM D 412), elongation of GREATER THAN 500 PERCENT (as per ASTM D 412), puncture resistance of GREATER THAN 1000N (as per ASTM E 154), peel adhesion to concrete GREATER THAN 1200N/m (as per ASTM D 903), hydrostatic head resistanceGREATER THAN 70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471 2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product AND work from certified manufacturers as per the direction of the Engineer In charge. Sqm635.25635.2553.41FalseNoneNoneFalseNoneFalse33928.70250
3532694127197NoneCSR 2023-24 Vol-2 P No.42 Item No.8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm366.45366.4553.41FalseNoneNoneFalseNoneFalse19572.09450
3532695127197NoneCSR 2023-24 Vol-2 P No.176 Item No.17.12Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete." Sqm974.4974.46.37FalseNoneNoneFalseNoneFalse6206.9280
3532696127197NoneCSR 2023-24 Vol-2 P No.13 Item No.6.3Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer in-charge of work Cum8874.08874.01.6FalseNoneNoneFalseNoneFalse14198.40
3532697127197NoneCSR 2023-24 Vol-2 P No.149 Item No.17.1Supplying, filling, spreading & levelling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. Cum1052.11052.15.6FalseNoneNoneFalseNoneFalse5891.760
3532698127197NoneCSR 2023-24 Vol-2 P No.149 Item No.17.2Supplying, filling, spreading & levelling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. Cum1245.31245.35.6FalseNoneNoneFalseNoneFalse6973.680
3532699127197NoneCSR 2023-24 Vol-2 P No.149 Item No.17.3Supplying, filling, spreading &levelling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. Cum1251.61251.64.0FalseNoneNoneFalseNoneFalse5006.40
17211162020000NoneNoneBuildingsPart-IV KKRDB SDP (Work code VNR23S4123421) EXTERNAL ELECTRIFICATION610908.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3532700127198NoneAS PER BESCOM COST DATE SHEETESTIMATED BY GESCOM ENGINEER , ESTIMATE SHEET UPLOADEDRs610908.0610908.01.0FalseNoneNoneFalseNoneFalse610908.00
17211162020000NoneNoneBuildingsPart-IV KKRDB SDP (Work code VNR23S4123421) DG SET1140125.75
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3532701127199NoneCSR 2023-24 Vol-6 Chapter-10 P No.41 Item No.10.1Supplying, installing, testing and commissioning of Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS 5514/ISO 3046/ ISO 8528 & IS 1002/ISO 3046 Generator set specifications." Set946003.8946003.81.0FalseNoneNoneFalseNoneFalse946003.80
3532702127199NoneCS.9R 2023-24 Vol-6 Chapter-2 PNo.6 Item No.2.5.9Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 4C X 2.5Sq.mm Mtr155.4155.4115.0FalseNoneNoneFalseNoneFalse17871.00
3532703127199NoneCSR 2023-24 Vol-6 Chapter-2 P No.6 Item No.2.5.16Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 4C X 4Sq.mm Mtr236.25236.25115.0FalseNoneNoneFalseNoneFalse27168.750
3532704127199NoneCSR 2023-24 Vol-6 Chapter-12 P No.54 ItemNo.12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia.( SR 2019-2020 ) Each3685.53685.52.0FalseNoneNoneFalseNoneFalse7371.00
3532705127199NoneCSR 2023-24 Vol-6 Chapter-12 P No.54 ItemNo.12.57Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. ( SR 2019-2020 ) Each4468.84468.82.0FalseNoneNoneFalseNoneFalse8937.60
3532706127199NoneCSR 2023-24 Vol-6Chapter-12P No.54 Item No.12.58.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. ( SR 2019-2020 ) 25x6mm GI strip Mtr134.4134.440.0FalseNoneNoneFalseNoneFalse5376.00
3532707127199NoneCSR 2023-24 Vol-6Chapter-12P No.55 Item No.12.58.6600x600x3mm GI Plate Each918.75918.752.0FalseNoneNoneFalseNoneFalse1837.50
3532708127199NoneCSR 2023-24 Vol-6Chapter-12P No.55 Item No.12.58.725x3mm Copper strip Mtr598.5598.530.0FalseNoneNoneFalseNoneFalse17955.00
3532709127199NoneCSR2023-24 Vol-6Chapter-12 PNo.55Item No.12.58.11600x600x3mm Copper plate Each7792.057792.052.0FalseNoneNoneFalseNoneFalse15584.10
3532710127199NoneCSR 2023-24 Vol-6 Chapter-6 P No.41 Item No.6.6.1Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc. complete( SR 2019-2020 ) In soil (ordinary) Mtr79.879.830.0FalseNoneNoneFalseNoneFalse2394.00
3532711127199NoneCSR 2023-24 Vol-6 Chapter-6 P No.41 Item No.6.6.2In soil (hard) Mtr107.1107.130.0FalseNoneNoneFalseNoneFalse3213.00
3532712127199NoneCSR 2023-24 Vol-6 Chapter-6 P No.41 Item No.6.7Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable. ( SR 2019-2020 ) Mtr105.0105.020.0FalseNoneNoneFalseNoneFalse2100.00
3532713127199NoneCSR 2023-24 Vol-6 Chapter-6 P No.41 Item No.6.8Providing and laying in position 100mm dia stone ware pipe in existing trench. ( SR 2019-2020 ) Mtr225.75225.7520.0FalseNoneNoneFalseNoneFalse4515.00
3532714127199NoneCSR 2023-24 Vol-6 Chapter-6 P No.42 Item No.6.9.5Supplying and fixing of class A (medium duty) GI pipe of wall thickness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1KV ( SR 2019-2020 ) 100mm Mtr934.5934.510.0FalseNoneNoneFalseNoneFalse9345.00
3532715127199NoneCSR 2023-24 Vol-6Chapter-6 P No.44Item No.6.19.3Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. ( SR 2019-2020 ) Using 10ft. Copper bonded rod with backfill compound. Each7623.07623.02.0FalseNoneNoneFalseNoneFalse15246.00
3532716127199NoneCSR 2023-24 Vol-6 Chapter-6P No.44 ItemNo.6.18.38 SWG GI Wire Mtr19.9519.9540.0FalseNoneNoneFalseNoneFalse798.00
3532717127199NoneCSR 2023-24 Vol-6 Chapter-6 P No.44 ItemNo.6.18.68 SWG Copper wire. Mtr110.25110.2540.0FalseNoneNoneFalseNoneFalse4410.00
3532718127199NoneAS PER GESCOM COST DATA SHEETElectrical Inspector charges Rs50000.050000.01.0FalseNoneNoneFalseNoneFalse50000.00
17211162020000NoneNoneBuildingsPart-IV KKRDB SDP (Work code VNR23S4123421)189114.45
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3532719127200NoneCSR 2023-24 Vol-6 Chapter-6 P No.31 Item No.6.8.5Supplying of ….TR invertor type split air conditioners suitable for operation on A/c supply single phase 50HZ 230V withhermetically sealed inverter compressor with air cooled condenser latest R410A/R-32 refrigerant fan motor start&run capacitors,Relay & over load protector internal unit with one indoor &one outdoor unit the condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube suitable capacity 3core sheatethed/pvc copper cable and a battery operated wireless remote unit 5star 1.5 ton capacity Each59172.7559172.752.0FalseNoneNoneFalseNoneFalse118345.50
3532720127200NoneCSR 2023-24 Vol-6 Chapter-6 P No.31 Item No.6.8.6Supplying of ….TR invertor type split air conditioners suitable for operation on A/c supply single phase 50HZ 230V withhermetically sealed inverter compressor with air cooled condenser latest R410A/R-32 refrigerant fan motor start&run capacitors,Relay & over load protector internal unit with one indoor &one outdoor unit the condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube suitable capacity 3core sheatethed/pvc copper cable and a battery operated wireless remote unit 5star 2 ton capacity Each70768.9570768.951.0FalseNoneNoneFalseNoneFalse70768.950
17211162020001NoneNoneBuildingsPart-III KKRDB Gen (Work code VNR23S4123320) C C ROAD2846176.78
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3532721127201NoneCSR 2023-24 Vol-3 P No.9 Item No.2.5(ii)AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle 100 Sqm413.0413.010.0FalseNoneNoneFalseNoneFalse4130.00
3532722127201NoneCSR 2023-24 Vol-1 P No.8 Item No.1.12Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. Cum99.799.7300.0FalseNoneNoneFalseNoneFalse29910.00
3532723127201NoneCSR 2023-24 Vol-3 P No.17 Item No.305.3.4(3.7)Compacting Original Ground Compacting original ground supporting embankment Loosening, levelling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. Cum110.25110.25300.0FalseNoneNoneFalseNoneFalse33075.00
3532724127201NoneCSR 2023-24 Vol-1 P No.7 Item No.1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. Cum497.7497.7300.0FalseNoneNoneFalseNoneFalse149310.00
3532725127201NoneCSR 2023-24 Vol-3 P No.23 Item No.4.2(V)Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 Cum2476.952476.95200.0FalseNoneNoneFalseNoneFalse495390.00
3532726127201NoneCSR 2023-24 Vol-3 P No.49 Item No.6.1Dry Lean Cement Concrete Sub- base Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing. DLC 1:5:10 Cum5166.05166.0150.0FalseNoneNoneFalseNoneFalse774900.00
3532727127201NoneCSR 2023-24 Vol-3 P No.49 Item No.6.2.1Cement Concrete Pavement with OPC/PPC/PSC Construction of M40 grade unreinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing CC Pavement -M30 Cum9514.059514.05125.0FalseNoneNoneFalseNoneFalse1189256.250
3532728127201NoneCSR 2023-24 Vol-3 P No.78 Item No.8.52Painting on concrete surface Providing Water based glossy paint (Green certified product) to Kerb Stones as per IS 164:2015 technical specifications including cleaning & surface preparation Sqm309.75309.75150.0FalseNoneNoneFalseNoneFalse46462.50
3532729127201NoneCSR 2023-24 Vol-3 P No.75 Item No.8.42.1Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finished in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) m318.15318.15300.0FalseNoneNoneFalseNoneFalse95445.00
3532730127201NoneCOMMON SR 2023-24, Vol-3, I No. 2.1.3, P.No - 15Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates Cum6288.456288.454.5FalseNoneNoneFalseNoneFalse28298.0250
17211162020001NoneNoneBuildingsPart-IV KKRDB SDP (Work code VNR23S4123421) Storm water drain752549.8
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3532731127202NoneCSR 2023-24 Vol-1 P No.8 Item No.1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m Cum107.1107.176.44FalseNoneNoneFalseNoneFalse8186.7240
3532732127202NoneCSR 2023-24 Vol-1 P No.15 Item No.2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates Cum6288.456288.4510.92FalseNoneNoneFalseNoneFalse68669.8740
3532733127202NoneCSR 2023-24 Vol-1 P No.17 Item No.2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Cum6804.06804.040.04FalseNoneNoneFalseNoneFalse272432.160
3532734127202NoneCSR 2023-24 Vol-1 P No.112 Item No.11Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per cum Cement Concrete Drain Walls ( 35% ) RCC WALL Cum2381.02381.025.48FalseNoneNoneFalseNoneFalse60667.880
3532735127202NoneCSR 2023-24 Vol-1 P No.112 Item No.15RCC Roof Slabs (50%) Roof Slab Concrete Quantity Cum3402.03402.014.56FalseNoneNoneFalseNoneFalse49533.120
3532736127202NoneCSR 2023-24 Vol-1 P No.18 Item No.2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) t93929.8593929.851.4FalseNoneNoneFalseNoneFalse131501.790
3532737127202NoneCSR 2023-24 Vol-2 P No.153 Item No.17.14Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. pre cast cover slab over drain Sqm1228.51228.591.0FalseNoneNoneFalseNoneFalse111793.50
3532738127202NoneCSR 2023-24 Vol-3 P No.87 Item No.9.1iLaying Reinforced Cement Concrete Pipe NP4 / Prestressed Concrete Pipe on First Class Bedding in Single Row .Laying Reinforced cement concrete pipe NP4/prestressed concrete pipe for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets . 1000 mm dia m9952.959952.955.0FalseNoneNoneFalseNoneFalse49764.750
17211162020000NoneNoneBuildingsPart-III KKRDB Gen (Work code VNR23S4123320) RWH33658.73
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3532739127203NoneCSR 2023-24 Vol-1 P No.5 Item No.1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m 1000 MM Dia Cum254.1254.15.09FalseNoneNoneFalseNoneFalse1293.3690
3532740127203NoneCSR 2023-24 Vol-1 P No.5 Item No.1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m 1000 MM Dia Cum271.95271.955.09FalseNoneNoneFalseNoneFalse1384.22550
3532741127203NoneCSR 2023-24 Vol-2 P No.175 Item No.17.5Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. Each1179.151179.1521.0FalseNoneNoneFalseNoneFalse24762.150
3532742127203NoneCSR 2023-24 Vol-2 P No.175 Item No.17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM Dia Cum1052.11052.10.85FalseNoneNoneFalseNoneFalse894.2850
3532743127203NoneCSR 2023-24 Vol-2 P No.175 Item No.17.2Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. Cum1245.31245.30.42FalseNoneNoneFalseNoneFalse523.0260
3532744127203NoneCSR 2023-24 Vol-2 P No.175 Item No.17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. Cum1251.61251.60.42FalseNoneNoneFalseNoneFalse525.6720
3532745127203NoneCSR 2023-24 Vol-2 P No.175 Item No.17.4Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. Cum1405.951405.950.42FalseNoneNoneFalseNoneFalse590.4990
3532746127203NoneCSR 2023-24 Vol-2 P No.177 Item No.17.14Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete.Sqm1228.51228.53.0FalseNoneNoneFalseNoneFalse3685.50
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17211162030000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17211162030000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17211162030001NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17211162030000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17211162030000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17211164900000NoneNoneELIGIBILITYThe Tenderer shall obtain the workdone certificate in the prescribed format from the Competent Authority not below the rank of Executive Engineer (District Level Officer) and scan the Original Certificate and attach the scanned file to the Bid. The Original Certificate/Certificates shall be produced at the time of opening of technical Bids for physical verification.None
17211164940000NoneNoneELIGIBILITYFinancial Year will be reckoned as the period between first day of April and Thirty first day of March of succeeding year(both days inclusive).None
17211164990000NoneNoneELIGIBILITYThe Tenderer shall scan the Original Ownership Documents/ Lease/ Hire commitment Agreement for the Machinery and attach the scanned file to the Bid. The Original Documents shall be produced at the time of opening of technical Bids for physical verification.None
17211165030000NoneNoneELIGIBILITYThe tenderer shall note that the scanned Documents can also be uploaded in the tasks created under Document/Evidence Required from the BidderNone
17211165070000NoneNoneELIGIBILITYThe Employer reserves the right to Reject any or all Tenders without assigning any reason.None
17211165110000NoneNoneELIGIBILITYThe Department is not responsible for any delay in accessing KPP-PortalNone
17211165180000NoneNoneELIGIBILITYTenderer shall note that the Tenders of those found Eligible as mentioned in Clause 3 - Qualification of the Tenderer in Section 2 : Instructions to Tenderers (ITT), will only be considered for evaluation.None
17211165250000NoneNoneELIGIBILITYThe rates of all the items appeared in Bill of Quantities are inclusive of all leads and liftsNone
17211165320000NoneNoneELIGIBILITYAs per circular of Govt. of Karnataka Government Order No. PWD 107 CRM 2013, Bangalore, Dated: 20.02.2014, If the tenderer uploads the Bank Guarantee, but does not produce original at the time of technical scrutiny, such tenders will not be disqualified either in the technical bid stage or financial bid stage. But the qualified tenderer (L1) must submit the original copy of the BG at the time of agreement.None
17211165380000NoneNoneELIGIBILITYThe contractor shall bound to comply the prevailing rules and regulations with regard to the EPF rules and any modifications before and after execution of agreementNone
17211165430000NoneNoneELIGIBILITYAfter the award of the contract, the contractor has to furnish the details in respect of labour employed and the EPF details for this work in every RA bill.None
17211165510000NoneNoneELIGIBILITYThe Increse in GST shall not be paid in the extended period of contract for which the contractor alone is responsible for delay as determined by the authority while granting the extension of time.None
17211165560000NoneNoneELIGIBILITYThe bidder should mention the UDIN No on the turnover certificate, failing which bid is rejected.None
17211165640000NoneNoneELIGIBILITYIf the bidder uploaded the false document while participating in the tender, the bidder will be responsible and action will be initiated as per the tender clause.None
17211165670000NoneNoneELIGIBILITYThe star rates inrespect of specified materials ( Cement, Steel and Bitumen) shall be payable as per CIRCULAR NO.PWD 159 CRM 2009 Bangalore Dated 30.09.2010None
17211165710000NoneNoneELIGIBILITYFinancial turnover of previous years shall be given a weight of 10% per year to bring them to the price level of the 2024-25 in the Technical Qualification Criteria mentioned in the next section.None
17211165830000NoneNoneELIGIBILITYThe work should be completed in 11 (Eleven) Months ( including monsoon)None
17211165880000NoneNoneELIGIBILITYThe earnest money deposit shall be in two parts i.e.,Part (1) Rs.1,00,000 by e.payment and balance Part (2) Rs. Balance amount as specified in the KPP portal shall be in the form of Bank Guarantee in the prescribed format obtained from the Nationalized / Schedule Bank FDR or specified small savings instrument pledged to the Executive Engineer, Public Works Department Division, HOSAPETE payable at HOSAPETE before the prescribed date and time of opening of Technical Bid without failNone
17211165930000NoneNoneELIGIBILITYAny dispute or difference or claim arising out of, or in connection with, or relating to the present contract or the breach, termination or invalid thereof shall be referred and settled under the Arbitration centre Karnataka (Domastic and international Rules 2012,by one or more arbitratiors appointed in accordance with its rulesNone
17211165980000NoneNoneELIGIBILITYThe deffect liability period is one year (1Year)from the date of actual completion of work.None
17211166050000NoneNoneELIGIBILITY18%GST Will paid extra to the executed quantitesNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneTo qualify for award of this contract, each Tenderer in his name should have in the last five years i.e.,2019-20, 2020-21 2021-22,2022-23 & 2023-24 b) Executed in any one year, the following minimum quantities of work 1 Earth work /Embankment/Sub Grade/Shoulder 3026.00 Cum 2.CC/PCC/RCC/DLC 968.00 Cum 3.Steel 60.51Tonnes 4. SSM/BBM/CC BLOCKS 433.76 Cum 5.Plastaring 4513.40 sqm.6.GSB 177.00 Cum 7.Flooring 2162.00 SqmPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneTo qualify for award of this contract, each Tenderer in his name should have in the last five years i.e.,2019-20, 2020-21 2021-22,2022-23 &2023-24 b) Satisfactorily completed, as prime contractor, at least one similar work such as Building Work of value not less than Rs.196.00 LakhsPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneRegistration CertificateCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneExcavator JCB/Hitachi/Excavator :Total 1 Nos, 1No own, 1 No Own/Lease B) Tippers : Total 4 Nos, 2No own, 2 No Own/Lease C) vehicle mounted water Tanker : Total 4 Nos, 2No own, 2 No Own/Lease D) Self loading Cement Concret Mixers: 1 No Own E) Pin Vibrators - Min 2 Nos- 1No Own 1No HireCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- machnories
NoneNoneNoneNoneTo qualify for award of this contract, each Tenderer in his name should have in the last five years i.e.2019-20, 2020-21 2021-22, 2022-23 &2023-24 a) Achieved in at least two financial years a minimum financial turnover (in all classes of civil engineering construction works only) of Rs. 784.01Lakhs.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneLiquid Assets and /or availability of credit facilities of no less than Rs.106.91lakhs (Credit Lines/letter of credit/ certificates from the banks for meeting the fund requirement etc.,Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateFalseTechnical Bid
Company Registration CertificateFalseTechnical Bid
Reserved Category CertificateFalseTechnical Bid
Small Scale Industries CertificateFalseTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1721119364000
version0
createdDateNone
modifiedDateNone
blockNumberOffice Of the Executive Engineer, PWD Division, 100 bed Hospital road,
streetNone
cityHosapete
stateKarnataka
pin583201
tenderRecallDTONone