| 1721290979000 | 0 | None | None | Water supply/sewage lines | Construction of mini water cistern near Anjaneya temple in Ward No. 12. And HDEP pipe line work from Tayamma Katte to Pampakrishna Murthy house. | 197948.83 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3541085 | 127819 | None | code01 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead Cement ConcreteM-202.10 (iv) Dismantling Stone Masonryb Rubble stone masonry in cement mortar.. | Cum | 755.79 | 755.79 | 13.2 | False | None | None | False | None | False | 9976.428 | 0 | | 3541086 | 127819 | None | code02 | 13.4 Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch)suitable for bore well confirming to IS 8034-2000 specifications, to worksite with testing of as per instructions of engineer incharge of work andlatest amendments etc. complete. 2.00 HP/1.5KW13.8.3 12 STG Each 17618 | Cum | 18498.0 | 18498.0 | 1.0 | False | None | None | False | None | False | 18498.0 | 0 | | 3541087 | 127819 | None | code03 | Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x4 m2 | Mtr | 167.0 | 167.0 | 50.0 | False | None | None | False | None | False | 8350.0 | 0 | | 3541088 | 127819 | None | code04 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor typ e NOTE: 1) DOLDirect Online Starter 2) S-D- Star Delta Starter Upto 6 HP pumps | Each | 8053.0 | 8053.0 | 1.0 | False | None | None | False | None | False | 8053.0 | 0 | | 3541089 | 127819 | None | code05 | Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box. | Each | 1424.0 | 1424.0 | 1.0 | False | None | None | False | None | False | 1424.0 | 0 | | 3541090 | 127819 | None | code06 | Providing main connection from pole PVC insulated sheathed steel wire cable in GI pipe as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit. | Mtr | 105.0 | 105.0 | 40.0 | False | None | None | False | None | False | 4200.0 | 0 | | 3541091 | 127819 | None | code07 | Supply and delivery at site Accessories for Single Phase pumpset like SS Groove Nipples,SS Studs & Nuts,Screw Clips &water proof Insulation Tape etc complete with ISI mark | Set | 5575.0 | 5575.0 | 1.0 | False | None | None | False | None | False | 5575.0 | 0 | | 3541092 | 127819 | None | code08 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. All kinds of soils. Depth upto 1.50 m | Cum | 324.0 | 324.0 | 46.2 | False | None | None | False | None | False | 14968.8 | 0 | | 3541093 | 127819 | None | code09 | Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 HDPE Grade PE60 63mm dia | Cum | 234.0 | 234.0 | 110.0 | False | None | None | False | None | False | 25740.0 | 0 | | 3541094 | 127819 | None | code10 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications | Cum | 198.0 | 198.0 | 39.6 | False | None | None | False | None | False | 7840.8 | 0 | | 3541095 | 127819 | None | code11 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. | Ltr | 9.45 | 9.45 | 2000.0 | False | None | None | False | None | False | 18900.0 | 0 | | 3541096 | 127819 | None | code12 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. | Kg | 192.0 | 192.0 | 302.4 | False | None | None | False | None | False | 58060.8 | 0 | | 3541097 | 127819 | None | code13 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal dia Pipes | Mtr | 299.0 | 299.0 | 38.0 | False | None | None | False | None | False | 11362.0 | 0 | | 3541098 | 127819 | None | code14 | KEB DEPOSITE | No | 5000.0 | 5000.0 | 1.0 | False | None | None | False | None | False | 5000.0 | 0 |
|