| 1721328261000 | 0 | None | None | Roads | Construction of CC Road and drain in ward nos 3 4 5 6 8 12 13 17 18 19 22 and UGD works near Kakalwar base Primary school and Purchase of Electrical Materials | 3897833.42 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3545951 | 128126 | None | code01 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. | Cum | 107.1 | 107.1 | 13.65 | False | None | None | False | None | False | 1461.915 | 0 | | 3545952 | 128126 | None | code02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS
Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm and down size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 2.28 | False | None | None | False | None | False | 14337.666 | 0 | | 3545953 | 128126 | None | code03 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications | Cum | 6639.15 | 6639.15 | 6.56 | False | None | None | False | None | False | 43552.824 | 0 | | 3545954 | 128126 | None | code04 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and
technical specification.All other type of structures | Tonne | 82961.6 | 82961.6 | 0.2826 | False | None | None | False | None | False | 23444.94816 | 0 | | 3545955 | 128126 | None | code05 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. | Cum | 107.1 | 107.1 | 35.1 | False | None | None | False | None | False | 3759.21 | 0 | | 3545956 | 128126 | None | code06 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS
Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm and down size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 5.85 | False | None | None | False | None | False | 36787.4325 | 0 | | 3545957 | 128126 | None | code07 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications | Cum | 6639.15 | 6639.15 | 19.22 | False | None | None | False | None | False | 127604.463 | 0 | | 3545958 | 128126 | None | code08 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and
technical specification.All other type of structures | Tonne | 82961.6 | 82961.6 | 0.784 | False | None | None | False | None | False | 65041.8944 | 0 | | 3545959 | 128126 | None | code09 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. | Cum | 107.1 | 107.1 | 31.2 | False | None | None | False | None | False | 3341.52 | 0 | | 3545960 | 128126 | None | code10 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS
Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm and down size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 5.2 | False | None | None | False | None | False | 32699.94 | 0 | | 3545961 | 128126 | None | code11 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications | Cum | 6639.15 | 6639.15 | 17.34 | False | None | None | False | None | False | 115122.861 | 0 | | 3545962 | 128126 | None | code12 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and
technical specification.All other type of structures | Tonne | 82961.6 | 82961.6 | 0.697 | False | None | None | False | None | False | 57824.2352 | 0 | | 3545963 | 128126 | None | code13 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. | Cum | 107.1 | 107.1 | 35.1 | False | None | None | False | None | False | 3759.21 | 0 | | 3545964 | 128126 | None | code14 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS
Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm and down size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 5.85 | False | None | None | False | None | False | 36787.4325 | 0 | | 3545965 | 128126 | None | code15 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications | Cum | 6639.15 | 6639.15 | 19.215 | False | None | None | False | None | False | 127571.26725 | 0 | | 3545966 | 128126 | None | code16 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and
technical specification.All other type of structures | Tonne | 82961.6 | 82961.6 | 0.7842 | False | None | None | False | None | False | 65058.48672 | 0 | | 3545967 | 128126 | None | code17 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. | Cum | 107.1 | 107.1 | 28.61 | False | None | None | False | None | False | 3064.131 | 0 | | 3545968 | 128126 | None | code18 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS
Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm and down size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 12.361 | False | None | None | False | None | False | 77731.53045 | 0 | | 3545969 | 128126 | None | code19 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications | Cum | 6639.15 | 6639.15 | 13.5365 | False | None | None | False | None | False | 89870.853975 | 0 | | 3545970 | 128126 | None | code20 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and
technical specification.All other type of structures | Tonne | 82961.6 | 82961.6 | 0.7612 | False | None | None | False | None | False | 63150.36992 | 0 | | 3545971 | 128126 | None | code21 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of Nsoils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. | Cum | 115.5 | 115.5 | 6.75 | False | None | None | False | None | False | 779.625 | 0 | | 3545972 | 128126 | None | code22 | Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 | Cum | 407.4 | 407.4 | 9.0 | False | None | None | False | None | False | 3666.6 | 0 | | 3545973 | 128126 | None | code23 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS
Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm and down size graded crushed coarse aggregates | Cum | 6039.6 | 6039.6 | 9.0 | False | None | None | False | None | False | 54356.4 | 0 | | 3545974 | 128126 | None | code24 | Construction of M30 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with OPC, coarse and fine aggregate conforming to IS 383, maximum size of
coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing | Cum | 9860.55 | 9860.55 | 11.07 | False | None | None | False | None | False | 109156.2885 | 0 | | 3545975 | 128126 | None | code25 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of Nsoils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. | Cum | 115.5 | 115.5 | 16.2 | False | None | None | False | None | False | 1871.1 | 0 | | 3545976 | 128126 | None | code26 | Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 | Cum | 407.4 | 407.4 | 16.2 | False | None | None | False | None | False | 6599.88 | 0 | | 3545977 | 128126 | None | code27 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS
Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm and down size graded crushed coarse aggregates | Cum | 6039.6 | 6039.6 | 10.8 | False | None | None | False | None | False | 65227.68 | 0 | | 3545978 | 128126 | None | code28 | Construction of M30 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with OPC, coarse and fine aggregate conforming to IS 383, maximum size of
coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing | Cum | 9860.55 | 9860.55 | 16.2 | False | None | None | False | None | False | 159740.91 | 0 | | 3545979 | 128126 | None | code29 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of Nsoils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. | Cum | 115.5 | 115.5 | 5.9 | False | None | None | False | None | False | 681.45 | 0 | | 3545980 | 128126 | None | code30 | Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 | Cum | 407.4 | 407.4 | 5.9 | False | None | None | False | None | False | 2403.66 | 0 | | 3545981 | 128126 | None | code31 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS
Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm and down size graded crushed coarse aggregates | Cum | 6039.6 | 6039.6 | 5.9 | False | None | None | False | None | False | 35633.64 | 0 | | 3545982 | 128126 | None | code32 | Construction of M30 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with OPC, coarse and fine aggregate conforming to IS 383, maximum size of
coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing | Cum | 9860.55 | 9860.55 | 8.85 | False | None | None | False | None | False | 87265.8675 | 0 | | 3545983 | 128126 | None | code33 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of Nsoils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. | Cum | 115.5 | 115.5 | 6.75 | False | None | None | False | None | False | 779.625 | 0 | | 3545984 | 128126 | None | code34 | Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 | Cum | 407.4 | 407.4 | 9.0 | False | None | None | False | None | False | 3666.6 | 0 | | 3545985 | 128126 | None | code35 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS
Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm and down size graded crushed coarse aggregates | Cum | 6039.6 | 6039.6 | 9.0 | False | None | None | False | None | False | 54356.4 | 0 | | 3545986 | 128126 | None | code36 | Construction of M30 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with OPC, coarse and fine aggregate conforming to IS 383, maximum size of
coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing | Cum | 9860.55 | 9860.55 | 17.8122 | False | None | None | False | None | False | 175638.08871 | 0 | | 3545987 | 128126 | None | code37 | Providing and constructing un-reinforced plain cementm concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per
Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383:2016:, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer
of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron
thick polythene film, wedges, steel plates including levelling he formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate
vibrators and finished in continuous operation including construction joints, primer, sealant, curing of concrete slabs for 14-days, and water finishing to lines and grade as per
drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the
directions of the Engineer-in-charge of the work. | Cum | 7091.7 | 7091.7 | 33.01 | False | None | None | False | None | False | 234097.017 | 0 | | 3545988 | 128126 | None | code38 | Providing and constructing un-reinforced plain cementm concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per
Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383:2016:, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer
of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron
thick polythene film, wedges, steel plates including levelling he formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate
vibrators and finished in continuous operation including construction joints, primer, sealant, curing of concrete slabs for 14-days, and water finishing to lines and grade as per
drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the
directions of the Engineer-in-charge of the work. | Cum | 7091.7 | 7091.7 | 23.52 | False | None | None | False | None | False | 166796.784 | 0 | | 3545989 | 128126 | None | code39 | Providing and constructing un-reinforced plain cementm concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per
Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383:2016:, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer
of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron
thick polythene film, wedges, steel plates including levelling he formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate
vibrators and finished in continuous operation including construction joints, primer, sealant, curing of concrete slabs for 14-days, and water finishing to lines and grade as per
drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the
directions of the Engineer-in-charge of the work. | Cum | 7091.7 | 7091.7 | 94.58 | False | None | None | False | None | False | 670732.986 | 0 | | 3545990 | 128126 | None | code40 | Supplying and fixing of T8 36/40W Fluorescent Tube with 36W power consumption within itial lumen of 2750(3000degK/ 4000degK)with rated avg life of greater than 10000hrs.Operatingvoltage range from 180V to 265V. 50Hz AC power Supply | No | 63.0 | 63.0 | 150.0 | False | None | None | False | None | False | 9450.0 | 0 | | 3545991 | 128126 | None | code41 | Supplying and fixing of 20/40W heavy duty open construction Ferromagnetic copper ballast for fluorescent tubes:Supplying and fixing of20/40W heavy duty open construction Ferromagnetic copperballast forfluorescent tubes,ClassHInsulated copperwire,Vacuum impregnated high quality with Low losssiliconsteel laminationoperatedon240V,50HzsupplywithIEC60920(Safety)&IEC60921(Performance).Operatingvoltagerangefrom180V to 265V, 50Hz AC power Supply. | No | 293.0 | 293.0 | 100.0 | False | None | None | False | None | False | 29300.0 | 0 | | 3545992 | 128126 | None | code42 | Accessories-Supplying & Fixing of 230 V 20/40 W starter forFluorescent Lamp | No | 30.0 | 30.0 | 100.0 | False | None | None | False | None | False | 3000.0 | 0 | | 3545993 | 128126 | None | code43 | Accessories-Supplying & Fixing of 230 V 20/40 W FluorescentLamp holder | No | 33.0 | 33.0 | 100.0 | False | None | None | False | None | False | 3300.0 | 0 | | 3545994 | 128126 | None | code44 | Supplying & Fixing of 250W Mercury Vapour lamp with E27Base, Lumen output greater than 22000 lumen & CRI45 .Avg Burning life greater than20,000hrs. Operatingvoltage rangefrom180Vto265V,50Hz AC power Supply | No | 454.0 | 454.0 | 100.0 | False | None | None | False | None | False | 45400.0 | 0 | | 3545995 | 128126 | None | code45 | Supplying & Fixing of High Intensity Discharge Electro Magneticballast suitable for Mercury Vapour Lamp with Class Hinsulated copper wire. Operating voltage range from180V to 265V, 50Hz AC power -Supply Ballast/Choke for Mercury Vapour Lamp- 250 W | No | 1681.0 | 1681.0 | 21.0 | False | None | None | False | None | False | 35301.0 | 0 | | 3545996 | 128126 | None | code46 | Accessories- Supplying & Fixing of Ignitor Suitable for 70 to 400 W
SV/MH fittings. Operating voltage range from 180V to 265V,
50Hz AC power Supply | No | 533.49 | 533.49 | 40.0 | False | None | None | False | None | False | 21339.6 | 0 | | 3545997 | 128126 | None | code47 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694 : 1990 & confirming to GTP of GROUP -A. 2.5 Sqmm | m | 42.0 | 42.0 | 600.0 | False | None | None | False | None | False | 25200.0 | 0 | | 3545998 | 128126 | None | code48 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694 : 1990 & confirming to GTP of GROUP -A. 6 Sqmm | m | 92.0 | 92.0 | 500.0 | False | None | None | False | None | False | 46000.0 | 0 | | 3545999 | 128126 | None | code49 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694 : 1990 & confirming to GTP of GROUP -A. 10 Sqmm | m | 108.0 | 108.0 | 500.0 | False | None | None | False | None | False | 54000.0 | 0 | | 3546000 | 128126 | None | code50 | Supplying & fixing of Porcelain fuse channel with cut out on
existing wooden/panel using necessary nuts, bolts and washers | No | 401.0 | 401.0 | 20.0 | False | None | None | False | None | False | 8020.0 | 0 | | 3546001 | 128126 | None | code51 | Supplying &Fixingofretrofittype-LED bulb...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K,CRI70% .efficacy80 lumenper W,life25000 burning hours and CompliancetoI S10322/IEC60598 ,LM79&LM80. The LED are driven by HFelectronic driver integratedinthe system,withPF0.95,powerlossshould5%oflampWage.,shortcircuit& open circuit protection to be integratedinthe circuit,THDlessthan20%,LifeasperLM79.Theoperatingin putvoltageshouldbebetween130to275V.BISApprovedandTestedbyNABL/CPRIaccreditedlaboratorywith2yearsWarrantyagainstanymanufacturing defect working under standard electrical condition.9W, 6500K | No | 154.0 | 154.0 | 200.0 | False | None | None | False | None | False | 30800.0 | 0 | | 3546002 | 128126 | None | code52 | Supplying &Fixingofretrofittype-LED bulb...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K,CRI70% .efficacy80 lumenper W,life25000 burning hours and CompliancetoI S10322/IEC60598 ,LM79&LM80. The LED are driven by HFelectronic driver integratedinthe system,withPF0.95,powerlossshould5%oflampWage.,shortcircuit& open circuit protection to be integratedinthe circuit,THDlessthan20%,LifeasperLM79.Theoperatingin putvoltageshouldbebetween130to275V.BISApprovedandTestedbyNABL/CPRIaccreditedlaboratorywith2yearsWarrantyagainstanymanufacturing defect working under standard electrical condition 12W, 6500K,item11.11.5 | No | 269.0 | 269.0 | 200.0 | False | None | None | False | None | False | 53800.0 | 0 | | 3546003 | 128126 | None | code53 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board.6A Pendant Holder item No 3.14.6 Page 10 Volume 06 | No | 30.0 | 30.0 | 70.0 | False | None | None | False | None | False | 2100.0 | 0 | | 3546004 | 128126 | None | code54 | Supply of LED floodlight luminaire with pressure die cast aluminium housing
body for optimal thermal dissipation. Lamp compartment comprising of anti
glare clear diffuser with Injection moulded polycarbonate/clear glass material,
delivering superior light output Rated life Burning Hrs 50000 hr Lumen
Maintenance of 70% CCT 5500K IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range
from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598,
LM 79 LM 80 Adherence with RoHS. UL approved MCPCB. Top access
street light with single screw to ensure ease of maintenance at the sight site
location with minimized minimal tools. LED Light fixture with W System
Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire
manufacturer should have in- house facility accredited by NABL / CPRI & any
Government certified agency & Design & Development facility certified by
ISO 9001:2008. Housing with supplier word mark / name shall be Engraved /
Embossing on the die cast housing / Body part Warranty of 2 Years against any
manufacturing defect working under standard electrical conditions as mentioned
above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram
make LED Source.item No 11.9.4 LED Floodlight 150W | No | 12490.0 | 12490.0 | 4.0 | False | None | None | False | None | False | 49960.0 | 0 | | 3546005 | 128126 | None | code55 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. All kinds of soils vol 1 IT no 1.17.3 Depth exceeding 3.0 m, but not exceeding 4.50 m | Cum | 504.0 | 504.0 | 303.23 | False | None | None | False | None | False | 152827.92 | 0 | | 3546006 | 128126 | None | code56 | Earth work excavation for pipeline trenches by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata.Ordinary/soft rock (without requiring blasting) Depth exceeding 3 m, but not exceeding 4.50 m Vol 1 it no 1.19.3 | Cum | 664.65 | 664.65 | 80.86 | False | None | None | False | None | False | 53743.599 | 0 | | 3546007 | 128126 | None | code57 | Earth work excavation for pipeline trenches by mechanical means as per drawing and technical specification, including setting out, construction of shoring, strutting, cost of blasting materials, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata.Hard rock Depth exceeding 3 m, but not exceeding 4.50 m vol 1 IT no 1.21.3 | Cum | 871.5 | 871.5 | 20.22 | False | None | None | False | None | False | 17621.73 | 0 | | 3546008 | 128126 | None | code58 | Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Providing and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Providing and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de-watering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. Constructing Brick Masonry Circular Machinehole 1.5 m internal dia. & 4.0 M depth includ. SFRC F&C vol 5 It No 16.16.4 | No | 146336.0 | 146336.0 | 1.0 | False | None | None | False | None | False | 146336.0 | 0 | | 3546009 | 128126 | None | code59 | Providing, lowering, laying, jointing, testing and commissioning of Glazed Stone Ware Pipes of following dia, conforming to IS 651:1992, IS 4127 with latest amendments, including conveying to work site, caulking with hemp dipped in tar and jointing with CM 1:1.5 using OPC, perfect linking and curing for 10 days and testing with water etc. with all lead, lifts and as per Technical Specifications. The cost to include the cost of all jointing materials, necessary survey works for laying of sewer lines etc. complete. The contractor will make own arrangements for procuring water for testing.200 mm dia. pipes vol 5 it no 16.1.3 | m | 714.0 | 714.0 | 150.0 | False | None | None | False | None | False | 107100.0 | 0 | | 3546010 | 128126 | None | code60 | Providing, lowering, laying, fixing, testing and commissioning of SW
JUNCTION PIPES, conforming to IS: 651:1992 with latest amendments, of sizes, including conveying to work site and caulking with hemp dipped in tar cement and jointing with CM 1:1.5 with sulphate resistant cement conforming to IS - 12330 with latest revisions and amendments, perfect linking, curing and testing with water, with all lead and lifts, including cost of jointing materials etc. complete for : (Contractor will make own arrangements for procuring water for testing). SW junction pipes of 200 mm x 100mm dia.vol 5 it no 16.33.2 | Each | 553.35 | 553.35 | 2.0 | False | None | None | False | None | False | 1106.7 | 0 | | 3546011 | 128126 | None | code61 | Refilling pipeline trenches and foundation with selected available earth from trench excavation and foundation including watering, consolidation layers of 15 cms., thickness including disposing off the surplus earth with a lead of 200 metres. Vol 1 it no 1.10 | Cum | 168.0 | 168.0 | 404.31 | False | None | None | False | None | False | 67924.08 | 0 | | 3546012 | 128126 | None | code62 | Cutting Asphalt /Concrete road surface using machine cutter for leakage pit with earth work excavation in all classifications of soil including all lead and lifts bailing out water with pumps including barricading, danger lighting etc., as per requirement and disposing of the excavated stuff as directed. After attending the leak, refilling the trench for 30 cm depth quarry dust above and around pipelines and balance with available earth in layers not exceeding 20 cms in depth, compacting Each deposited layer by ramming including watering and consolidation by mechanical means approved by Engineer Incharge. IT NO 3.3 VOL 5 | Cum | 1214.85 | 1214.85 | 14.0 | False | None | None | False | None | False | 17007.9 | 0 | | 3546013 | 128126 | None | code63 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates Vol 1 It no 2.1.6 | Cum | 6555.15 | 6555.15 | 14.0 | False | None | None | False | None | False | 91772.1 | 0 |
|