3544735 | 128035 | None | NUR01 | Demolishing R.C.C. work manually/ by mechanicalmeans including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. | Cum | 3148.95 | 3148.95 | 23.22 | False | None | None | False | None | False | 73118.619 | 0 |
3544736 | 128035 | None | NUR02 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. In cement mortar | Cum | 1335.64 | 1335.64 | 54.01 | False | None | None | False | None | False | 72137.9164 | 0 |
3544737 | 128035 | None | NUR03 | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Tipper 10 m3 ) as per direction of Engineer-in-charge. | Cum | 154.46 | 154.46 | 77.22 | False | None | None | False | None | False | 11927.4012 | 0 |
3544738 | 128035 | None | NUR04 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking to the appropriate disposal area as per direction of Engineerin-charge. Of area 3 m² and below | Cum | 311.52 | 311.52 | 27.9 | False | None | None | False | None | False | 8691.408 | 0 |
3544739 | 128035 | None | NUR05 | Earth work in surface excavation by mechanical means for lowering and leveling the ground without blasting for all works other than foundation in Ordinary/ Soft rock and depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage of machinery and other appurtenances required to complete the work as per direction of Engineer-in-charge. In Ordinary/Soft rock upto 300 mm depth | Cum | 469.88 | 469.88 | 90.0 | False | None | None | False | None | False | 42289.2 | 0 |
3544740 | 128035 | None | NUR06 | Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage of machinery and other appurtenaces required to complete the work In In all kinds of soils Depth upto 3 m. as per direction of Engineer-in-charge. | Cum | 132.4 | 132.4 | 189.95 | False | None | None | False | None | False | 25149.38 | 0 |
3544741 | 128035 | None | NUR07 | Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work. | Cum | 110.3 | 110.3 | 279.95 | False | None | None | False | None | False | 30878.485 | 0 |
3544742 | 128035 | None | NUR08 | Cost of Haulage Excluding Loading and Unloading Taking output 18 t load and lead 10 km = 180 t.km as per direction of Engineer-in-charge. | Cum | 199.37 | 199.37 | 357.18 | False | None | None | False | None | False | 71210.9766 | 0 |
3544743 | 128035 | None | NUR09 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20percent E.C. / Lindane 20percent E.C. at 3.19 l/m2 including cost of chemical, diluting in water to one percentconcentration, labour, usage charges of machinery, complete as per specifications. as per direction of Engineer-in-charge. | Sqm | 153.16 | 153.16 | 66.0 | False | None | None | False | None | False | 10108.56 | 0 |
3544744 | 128035 | None | NUR10 | Providing Size Stone masonry with hard stone in foundation and plinth with Cement mortar 1 6 (1 cement 6 coarse sand) complete with all lead and lift as per the engineer incharge. | Cum | 8292.9 | 8292.9 | 73.1 | False | None | None | False | None | False | 606210.99 | 0 |
3544745 | 128035 | None | NUR11 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m, as per direction of Engineer-in-charge. | Cum | 345.27 | 345.27 | 216.0 | False | None | None | False | None | False | 74578.32 | 0 |
3544746 | 128035 | None | NUR12 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications and as per direction of Engineer-in-charge..Mix 1 3 6 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 8069.65 | 8069.65 | 39.82 | False | None | None | False | None | False | 321333.463 | 0 |
3544747 | 128035 | None | NUR13 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenancesrequired to complete the work as per technical specifications and as per direction of Engineer-in-charge..M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for footing. | Cum | 8224.13 | 8224.13 | 6.07 | False | None | None | False | None | False | 49920.4691 | 0 |
3544748 | 128035 | None | NUR14 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenancesrequired to complete the work as per technical specifications as per direction of Engineer-in-charge..M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for COLUMN UPTO PLINTH. | Cum | 8224.13 | 8224.13 | 1.74 | False | None | None | False | None | False | 14309.9862 | 0 |
3544749 | 128035 | None | NUR15 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications as per direction of Engineer-in-charge..M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Plinth Beam. | Cum | 8224.12 | 8224.12 | 13.19 | False | None | None | False | None | False | 108476.1428 | 0 |
3544750 | 128035 | None | NUR16 | Add Extra for Formwork, Centering shuttering complete for item no13 with all lead and lift as per the directions of engineer in charge and Scaffolding Form work for Footing | Cum | 657.93 | 657.93 | 6.07 | False | None | None | False | None | False | 3993.6351 | 0 |
3544751 | 128035 | None | NUR17 | Add Extra for Formwork, Centering shuttering complete for item no14 with all lead and lift as per the directions of engineer in charge and Scaffolding Form work for Coulmn upto Plinth level | Cum | 5756.89 | 5756.89 | 1.74 | False | None | None | False | None | False | 10016.9886 | 0 |
3544752 | 128035 | None | NUR18 | Add Extra for Formwork, Centering shuttering complete for item no15 with all lead and lift as per the directions of engineer in charge and Scaffolding Form work for Plinth Beam. | Cum | 4112.06 | 4112.06 | 13.19 | False | None | None | False | None | False | 54238.0714 | 0 |
3544753 | 128035 | None | NUR19 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for column. as per direction of Engineer-in-charge. | Cum | 8882.21 | 8882.21 | 4.64 | False | None | None | False | None | False | 41213.4544 | 0 |
3544754 | 128035 | None | NUR20 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications and as per direction of Engineer-in-charge.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for lintel and Roof beam. | Cum | 8882.21 | 8882.21 | 8.79 | False | None | None | False | None | False | 78074.6259 | 0 |
3544755 | 128035 | None | NUR21 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications and as per direction of Engineer-in-charge.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for slab. | Cum | 8882.21 | 8882.21 | 36.34 | False | None | None | False | None | False | 322779.5114 | 0 |
3544756 | 128035 | None | NUR22 | Add Extra for Formwork, Centering shuttering complete for item no19 with all lead and lift as per the directions of engineer in charge and Scaffolding Form work for GROUND FLOOR COLUMN | Cum | 6217.55 | 6217.55 | 4.64 | False | None | None | False | None | False | 28849.432 | 0 |
3544757 | 128035 | None | NUR23 | Add Extra for Formwork, Centering shuttering complete for item no20 with all lead and lift as per the directions of engineer in charge and Scaffolding Form work for GROUND FLOOR'LINTEL AND ROOF BEAM | Cum | 5329.33 | 5329.33 | 8.79 | False | None | None | False | None | False | 46844.8107 | 0 |
3544758 | 128035 | None | NUR24 | Add Extra for Formwork, Centering shuttering complete for item no21 with all lead and lift as per the directions of engineer in charge and Scaffolding Form work for GROUND FLOOR STAIRCASE AND ROOF SLAB | Cum | 4441.11 | 4441.11 | 36.34 | False | None | None | False | None | False | 161389.9374 | 0 |
3544759 | 128035 | None | NUR25 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. as per direction of Engineer-in-charge. | Tonne | 116115.19 | 116115.19 | 7.78 | False | None | None | False | None | False | 903376.1782 | 0 |
3544760 | 128035 | None | NUR26 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I)-2005 and constructed with CM 1 4 as per IS 2572 2005 including cost of all materials, labour, scaffolding and curing, usagecharges of machinery etc complete as per specifications. as per direction of Engineer-in-charge. | Sqm | 1597.84 | 1597.84 | 332.15 | False | None | None | False | None | False | 530722.556 | 0 |
3544761 | 128035 | None | NUR27 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS2185 (Part - I) - 2005 and constructed with CM 1 4 as per IS 2572 2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc. as per direction of Engineer-in-charge. complete as per specifications for Ground Floor | Sqm | 1432.99 | 1432.99 | 12.5 | False | None | None | False | None | False | 17912.375 | 0 |
3544762 | 128035 | None | NUR28 | Providing 12 mm cement plaster with cement mortar 1 4 (1 cement 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. for Ground Floor | Sqm | 330.99 | 330.99 | 179.67 | False | None | None | False | None | False | 59468.9733 | 0 |
3544763 | 128035 | None | NUR29 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1 4 (1 cement 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in charge. for Ground Floor | Sqm | 382.85 | 382.85 | 332.15 | False | None | None | False | None | False | 127163.6275 | 0 |
3544764 | 128035 | None | NUR30 | Providing 20 mm cement plaster with cement mortar 1 3 (1 cement 3 coarse sand) finished with a floating coat of neat cement to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge for Ground floor | Sqm | 556.84 | 556.84 | 155.25 | False | None | None | False | None | False | 86449.41 | 0 |
3544765 | 128035 | None | NUR31 | Polyurethane based Single Component for New Surface Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400percent and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats at 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer at150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification and with a 10 years warranty on product and work from certified manufacturers and as per the direction of the Engineer In charge. for 1st floor | Sqm | 1081.68 | 1081.68 | 219.0 | False | None | None | False | None | False | 236887.92 | 0 |
3544766 | 128035 | None | NUR32 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications and as per direction of Engineer-in-charge.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-TERRACE FLOOR | Cum | 8691.8 | 8691.8 | 16.43 | False | None | None | False | None | False | 142806.274 | 0 |
3544767 | 128035 | None | NUR33 | Providing Honne wood frames of doors, windows, clerestory windows,ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications and as per direction of Engineer-in-charge. | Cum | 179220.05 | 179220.05 | 0.56 | False | None | None | False | None | False | 100363.228 | 0 |
3544768 | 128035 | None | NUR34 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification and as per direction of Engineer-in-charge.do- 35 mm thick both side commercial | Sqm | 4311.96 | 4311.96 | 24.26 | False | None | None | False | None | False | 104608.1496 | 0 |
3544769 | 128035 | None | NUR35 | Providing and laying Vitrified tiles with thickness 9-10 mm in floor with different sizes with water absorption less than 0.08percent and conforming to IS 15622, of approved brand and manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). As per direction of Engineer-in-charge.Size of Tile 600x600mm | Sqm | 1606.92 | 1606.92 | 133.87 | False | None | None | False | None | False | 215118.3804 | 0 |
3544770 | 128035 | None | NUR36 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600mm | Sqm | 271.28 | 271.28 | 133.87 | False | None | None | False | None | False | 36316.2536 | 0 |
3544771 | 128035 | None | NUR37 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1 6, 20 mm thick, and joints finishedwith cement mortar 1 3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications, as per direction of Engineer-in-charge. | Sqm | 6915.7 | 6915.7 | 19.43 | False | None | None | False | None | False | 134372.051 | 0 |
3544772 | 128035 | None | NUR38 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1 2 4 (1 cement 2 coarse sand 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. | Sqm | 3620.12 | 3620.12 | 2.4 | False | None | None | False | None | False | 8688.288 | 0 |
3544773 | 128035 | None | NUR39 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge | Sqm | 129.5 | 129.5 | 511.82 | False | None | None | False | None | False | 66280.69 | 0 |
3544774 | 128035 | None | NUR40 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge. | Sqm | 68.79 | 68.79 | 511.82 | False | None | None | False | None | False | 35208.0978 | 0 |
3544775 | 128035 | None | NUR41 | Wall painting with premium acrylic emulsion paint of interior grade,having VOC(Volatile Organic Compound) content less than 50 g/L of approved brand and manufacture,including applying additional coats wherever required to achieve even shade and colour.Two coats as per specifications and as per directions of Engineer in charge. | Sqm | 142.78 | 142.78 | 511.82 | False | None | None | False | None | False | 73077.6596 | 0 |
3544776 | 128035 | None | NUR42 | Finishing walls with textured exterior paint of required shade New work (Two coats applied at 3.28 ltr/10 m²) over and including priming coat of exterior primer applied at 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge for ground floor | Sqm | 367.33 | 367.33 | 167.85 | False | None | None | False | None | False | 61656.3405 | 0 |
3544777 | 128035 | None | NUR43 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., ofrequired size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, as per direction of Engineer-in-charge. | Kgs | 733.37 | 733.37 | 168.0 | False | None | None | False | None | False | 123206.16 | 0 |
3544778 | 128035 | None | NUR44 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge. | Sqm | 72.69 | 72.69 | 25.38 | False | None | None | False | None | False | 1844.8722 | 0 |
3544779 | 128035 | None | NUR45 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied at 0.90 ltr/10 m² over an under coat of primer applied at0.75 ltr/10 m² of approved brand and manufacture to give an
even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 182.71 | 182.71 | 25.38 | False | None | None | False | None | False | 4637.1798 | 0 |
3544780 | 128035 | None | NUR46 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding, as per direction of Engineer-in-charge. | Kg | 218.06 | 218.06 | 696.6 | False | None | None | False | None | False | 151900.596 | 0 |
3544781 | 128035 | None | NUR47 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in charge | Sqm | 149.27 | 149.27 | 23.22 | False | None | None | False | None | False | 3466.0494 | 0 |
3544782 | 128035 | None | NUR48 | Providing and fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardwareand Multi point locking system with touch lock. Wall thickness of frame and sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor TandP's shall not be made) as per direction of Engineer-in-charge. | Sqm | 8740.73 | 8740.73 | 22.14 | False | None | None | False | None | False | 193519.7622 | 0 |
3544783 | 128035 | None | NUR49 | Providing and fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor TandP's shall not be made) as per direction of Engineer-in-charge. | Sqm | 7423.26 | 7423.26 | 1.08 | False | None | None | False | None | False | 8017.1208 | 0 |
3544784 | 128035 | None | NUR50 | Providing and laying cinder concrete in cement 1 15 (1 cement 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications and as per direction of Engineer-in-charge. | Cum | 2618.07 | 2618.07 | 1.0 | False | None | None | False | None | False | 2618.07 | 0 |
3544785 | 128035 | None | NUR51 | Providing and laying Polished Glazed Vitrified tiles with thickness 10mm in floor with different sizes with water absorption less than 0.08percentand conforming to IS 15622, of approved brand and manufacturer, in allcolours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS 15477, in average 6 mmthickness, including grouting of joints (Payment for grouting of joints tobe made separately).as per direction of Engineer-in-charge.Size of Tile 600x600 mm | Sqm | 1721.15 | 1721.15 | 42.66 | False | None | None | False | None | False | 73424.259 | 0 |
3544786 | 128035 | None | NUR52 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08percent and conforming to IS 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1 4 (1 cement 4 coarse sand), jointing with grey cement slurry at 3.3 kg/ m2 including grouting the joints with white cement andmatching pigments etc., as per direction of Engineer-in-charge.complete Size of Tile 600x600 mm | Sqm | 1486.21 | 1486.21 | 33.12 | False | None | None | False | None | False | 49223.2752 | 0 |
3544787 | 128035 | None | NUR53 | Providing and fixing Structural Steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kgs | 137.59 | 137.59 | 450.0 | False | None | None | False | None | False | 61915.5 | 0 |
3544788 | 128035 | None | NUR54 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied at 0.90 ltr/10 m² over an under coat of primer applied at 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 184.03 | 184.03 | 10.0 | False | None | None | False | None | False | 1840.3 | 0 |
3544789 | 128035 | None | NUR55 | Providing and fixing factory made single extruded WPC (Wood PolymerComposite) solid door/window/Clerestory windows and other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension
Grade), calcium carbonate and natural fibres (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for100 g) fabricated with miter joints after applying PVC solvent cement andscrewed with full body threaded star headed SS screws having minimumframe density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) and1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus ofelasticity 900 N/mm2 and resistance to spreadof flame of Class A categorywith property of being termite/borer proof,water/moisture proof and fireretardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge.(Fixtures shall be paid for separately) and as per direction of Engineer-in-charge. Size 62 x 150mm | Mtr | 1047.49 | 1047.49 | 21.2 | False | None | None | False | None | False | 22206.788 | 0 |
3544790 | 128035 | None | NUR56 | Providing and fixing factory made Green certified, Anti Termite, UV resistant,high water absorbant single extruded WPC (Wood PolymerComposite) solidplain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers(wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimumdensity of 650 kg/m3 andscrew withdrawal strength of 1800 N (Face) and 900 N (Edge), minimumcompressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 andresistance to spread of flame of Class A category with property of beingtermite/borer proof, water/moisture proof and fire retardant and fixingwith stainless steel butt hinges of required size with necessary full bodythreaded star headed counter sunk S.S screws The cost includes cost ofmaterials, transportation, labour and fixing charges.(Cost of Fixtures to bepaid separately) and as per direction of Engineer-in-charge. 35 mm thickness | Sqm | 5245.22 | 5245.22 | 6.3 | False | None | None | False | None | False | 33044.886 | 0 |
3544791 | 128035 | None | NUR57 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete and as per direction of Engineer-in-charge. | Nos | 1365.5 | 1365.5 | 10.0 | False | None | None | False | None | False | 13655.0 | 0 |
3544792 | 128035 | None | NUR58 | Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc.2037 -Ball beaing hinges heavy duty and as per direction of Engineer-in-charge.125x65x2.12mm | Nos | 71.39 | 71.39 | 20.0 | False | None | None | False | None | False | 1427.8 | 0 |
3544793 | 128035 | None | NUR59 | Providing and fixing stainless steel 304 grade fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-incharge 200mm length | Nos | 1947.0 | 1947.0 | 10.0 | False | None | None | False | None | False | 19470.0 | 0 |
3544794 | 128035 | None | NUR60 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete as per direction of Engineer-in-charge. | Each | 1583.56 | 1583.56 | 2.0 | False | None | None | False | None | False | 3167.12 | 0 |
3544795 | 128035 | None | NUR61 | Providing and fixing storage unit of 0.60m depth made out of 19mm thick commercial ply vertical support finished in approved 1.00mm laminate with 12mm thick ply packing internally finished 1.00mm laminate of approved colour and shade shelves shall be formed out of 19mm ply finished both side 1.00mm laminate of approved shade and colour and 19mm thick shutters formed out of 19mm thick ply finished with 1.00mm thick laminate on both side of approved shade and colour with ironmongery (stainless steel with locks etc...) etc., complete the rate includes cost of all materials, labour charges, complete as per specification and as per direction of Engineer-in-charge.. | Sqm | 15340.0 | 15340.0 | 3.78 | False | None | None | False | None | False | 57985.2 | 0 |
3544796 | 128035 | None | NUR62 | Classroom Chalk board of size 1800mmx1200mm made with 8mm thk Particle Board With M.S. Sheet in Green Colour and with Aluminium Frame including Labour, material, trasportion charges, installation Charges with all lead and lift complete as per the specification and Engineer Incharge. | Nos | 7180.0 | 7180.0 | 2.0 | False | None | None | False | None | False | 14360.0 | 0 |
3544797 | 128035 | None | NUR63 | Providing and fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge. 0.63 mm thick with zinc coating not less than 275 g/ m² | Sqm | 1140.94 | 1140.94 | 20.0 | False | None | None | False | None | False | 22818.8 | 0 |
3544798 | 128035 | None | NUR64 | Constructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75in cement mortar 1 6, bed concrete 150mm thick with 1 3 6, plastering 12 mm thick with cement mortar 1 4, CC 1 2 4 coping 75mm thk for fixing CI cover and frame etc. excluding the cost of CI frame and cover and as per direction of Engineer-in-charge. | Each | 6218.72 | 6218.72 | 2.0 | False | None | None | False | None | False | 12437.44 | 0 |
3544799 | 128035 | None | NUR65 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot and cold water supply, including all CPVCplain and brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes and fittings with one step CPVCsolvent cement and the cost of cutting chases and making good thesame including testing of joints complete as per direction of Engineer inCharge. Concealed work, including cutting chases and making good thewalls etc.as per direction of Engineer-in-charge.25 mm nominal dia pipes | Mtr | 619.15 | 619.15 | 100.0 | False | None | None | False | None | False | 61915.0 | 0 |
3544800 | 128035 | None | NUR66 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes | Mtr | 384.21 | 384.21 | 200.0 | False | None | None | False | None | False | 76842.0 | 0 |
3544801 | 128035 | None | NUR67 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work-Exposed on wall 40 mm nominal dia Pipes | Mtr | 695.73 | 695.73 | 75.0 | False | None | None | False | None | False | 52179.75 | 0 |
3544802 | 128035 | None | NUR68 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require As per direction of Engineer-in-charge.White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps fittings and brackets, cutting and making good the walls wherever require | Each | 4000.44 | 4000.44 | 4.0 | False | None | None | False | None | False | 16001.76 | 0 |
3544803 | 128035 | None | NUR69 | Providing and fixing Angle cock with wall flange made of Stainless steel with all concealed fitting arrangements and all necessary accesoriescomplete - Class b Premium and as per direction of Engineer-in-charge. | Each | 2489.56 | 2489.56 | 4.0 | False | None | None | False | None | False | 9958.24 | 0 |
3544804 | 128035 | None | NUR70 | Providing and fixing Bib cock Two way with wall flange made of Stainless steel with all concealed fitting arrangements and all necessary accessories complete - Class B Premium and as per direction of Engineer-in-charge. | Each | 4298.98 | 4298.98 | 4.0 | False | None | None | False | None | False | 17195.92 | 0 |
3544805 | 128035 | None | NUR71 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality and make and as per the direction of Engineer-in-charge | Each | 1051.38 | 1051.38 | 4.0 | False | None | None | False | None | False | 4205.52 | 0 |
3544806 | 128035 | None | NUR72 | Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements and all necessary accessories complete and as per direction of Engineer-in-charge. | Each | 285.56 | 285.56 | 4.0 | False | None | None | False | None | False | 1142.24 | 0 |
3544807 | 128035 | None | NUR73 | PVC pipe - OD 110mm and 6 Kg/sqcm and as per direction of Engineer-in-charge. | Mtr | 330.99 | 330.99 | 60.0 | False | None | None | False | None | False | 19859.4 | 0 |
3544808 | 128035 | None | NUR74 | PVC pipe - OD 75mm and 6 Kg/sqcm and as per direction of Engineer-in-charge. | Mtr | 159.65 | 159.65 | 44.0 | False | None | None | False | None | False | 7024.6 | 0 |
3544809 | 128035 | None | NUR75 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank and as per direction of Engineer-in-charge. | Ltr | 11.68 | 11.68 | 2000.0 | False | None | None | False | None | False | 23360.0 | 0 |
3544810 | 128035 | None | NUR76 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe mm dia mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary and as per direction of Engineer-in-charge.19/20mm dia 2mm thick. | Mtr | 77.88 | 77.88 | 180.0 | False | None | None | False | None | False | 14018.4 | 0 |
3544811 | 128035 | None | NUR77 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe mm dia mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary and as per direction of Engineer-in-charge. 25mm dia 2mm thick. | Mtr | 92.04 | 92.04 | 200.0 | False | None | None | False | None | False | 18408.0 | 0 |
3544812 | 128035 | None | NUR78 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe ……mm dia ....... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary and as per direction of Engineer-in-charge.32mm dia 2.5mm thick. | Mtr | 121.54 | 121.54 | 180.0 | False | None | None | False | None | False | 21877.2 | 0 |
3544813 | 128035 | None | NUR79 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe ……mm dia ....... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary and as per direction of Engineer-in-charge.40mm dia 2.5mm thick. | Mtr | 173.46 | 173.46 | 100.0 | False | None | None | False | None | False | 17346.0 | 0 |
3544814 | 128035 | None | NUR80 | Groove works Supplying heavy gauge PVC Conduit Pipe....dia.......mm thick with suitable size bends,metal junction boxes adhesiv epaste etc.,by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18SWG GI fish wire run throughout the conduit wherever necessary and as per direction of Engineer-in-charge.19/20mm dia 2mm thick. | Mtr | 80.24 | 80.24 | 420.0 | False | None | None | False | None | False | 33700.8 | 0 |
3544815 | 128035 | None | NUR81 | Groove works Supplying heavy gauge PVC Conduit Pipe....dia.......mm thick with suitable size bends,metal junction boxes adhesiv epaste etc.,by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18SWG GI fish wire run throughout the conduit wherever necessary and as per direction of Engineer-in-charge. 32 mm dia 2.5mm thick | Mtr | 93.22 | 93.22 | 340.0 | False | None | None | False | None | False | 31694.8 | 0 |
3544816 | 128035 | None | NUR82 | Supplying and fixing sheet Metal box made out of 18SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. As per direction of Engineer-in-charge. 75 x 75 x 65 mm | Each | 125.08 | 125.08 | 50.0 | False | None | None | False | None | False | 6254.0 | 0 |
3544817 | 128035 | None | NUR83 | Supplying and fixing sheet Metal box made out of 18SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. As per direction of Engineer-in-charge. 100 x 75 x 65 mm | Each | 139.24 | 139.24 | 45.0 | False | None | None | False | None | False | 6265.8 | 0 |
3544818 | 128035 | None | NUR84 | Supplying and fixing sheet Metal box made out of 18SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. As per direction of Engineer-in-charge. 135 x 75 x 65 mm | Each | 164.02 | 164.02 | 12.0 | False | None | None | False | None | False | 1968.24 | 0 |
3544819 | 128035 | None | NUR85 | Supplying and fixing sheet Metal box made out of 18SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. As per direction of Engineer-in-charge. 200 x 90 x 65 mm | Each | 211.22 | 211.22 | 15.0 | False | None | None | False | None | False | 3168.3 | 0 |
3544820 | 128035 | None | NUR86 | Supplying and fixing sheet Metal box made out of 18SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. As per direction of Engineer-in-charge. 200 x 200 x 65 mm | Each | 410.64 | 410.64 | 10.0 | False | None | None | False | None | False | 4106.4 | 0 |
3544821 | 128035 | None | NUR87 | Supplying and fixing PVC/metal conduit Deep junction box and as per direction of Engineer-in-charge.19/20 mm deep Junction box | Each | 57.82 | 57.82 | 50.0 | False | None | None | False | None | False | 2891.0 | 0 |
3544822 | 128035 | None | NUR88 | Supplying and fixing PVC/metal conduit Deep junction box and as per direction of Engineer-in-charge.25 mm deep Junction box | Each | 66.08 | 66.08 | 24.0 | False | None | None | False | None | False | 1585.92 | 0 |
3544823 | 128035 | None | NUR89 | Supplying and fixing PVC/metal conduit Deep junction box and as per direction of Engineer-in-charge.32 mm deep Junction box | Each | 71.98 | 71.98 | 6.0 | False | None | None | False | None | False | 431.88 | 0 |
3544824 | 128035 | None | NUR90 | Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using2x1.5Sqmm(PhaseandNeutral)and1x1.0sqmm(Earthwire)FRLS multi strand PVC insulated copper wire(confirmingtoIS-694 and latest amendments)with a6Amps flush type SPcontrols witch shall befixed on the existing plastic sheet/gangbox,the other end of the wires shall be terminated with sufficient loose length in a wood/PVCround block.complete for each outlet.Three out let in a Row,above 6Mts up to10Mtr from tapping point to out let via switches and as per direction of Engineer-in-charge. | Point | 1221.3 | 1221.3 | 20.0 | False | None | None | False | None | False | 24426.0 | 0 |
3544825 | 128035 | None | NUR91 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specifiedIS-694 2010 and as per direction of Engineer-in-charge. 1 mm2 | Mtr | 22.42 | 22.42 | 220.0 | False | None | None | False | None | False | 4932.4 | 0 |
3544826 | 128035 | None | NUR92 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specifiedIS-694 2010 and as per direction of Engineer-in-charge. 1.5 mm2 | Mtr | 30.68 | 30.68 | 220.0 | False | None | None | False | None | False | 6749.6 | 0 |
3544827 | 128035 | None | NUR93 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specifiedIS-694 2010 and as per direction of Engineer-in-charge. 2.5 mm2 | Mtr | 49.56 | 49.56 | 220.0 | False | None | None | False | None | False | 10903.2 | 0 |
3544828 | 128035 | None | NUR94 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specifiedIS-694 2010 and as per direction of Engineer-in-charge. 4 mm2 | Mtr | 74.34 | 74.34 | 160.0 | False | None | None | False | None | False | 11894.4 | 0 |
3544829 | 128035 | None | NUR95 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specifiedIS-694 2010 and as per direction of Engineer-in-charge. 6 mm2 | Mtr | 108.56 | 108.56 | 145.0 | False | None | None | False | None | False | 15741.2 | 0 |
3544830 | 128035 | None | NUR96 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specifiedIS-694 2010 and as per direction of Engineer-in-charge.10 mm2 | Mtr | 197.06 | 197.06 | 130.0 | False | None | None | False | None | False | 25617.8 | 0 |
3544831 | 128035 | None | NUR97 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cuttinginBrick/C.Cwall,including necessary rawl plugs,Machine/NF screws etc., complete as per direction of Engineer-in-charge.3 Way | Each | 146.32 | 146.32 | 120.0 | False | None | None | False | None | False | 17558.4 | 0 |
3544832 | 128035 | None | NUR98 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cuttinginBrick/C.Cwall,including necessary rawl plugs,Machine/NF screws etc complete as per direction of Engineer-in-charge.6 Way | Each | 204.14 | 204.14 | 10.0 | False | None | None | False | None | False | 2041.4 | 0 |
3544833 | 128035 | None | NUR99 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cuttinginBrick/C.Cwall,including necessary rawl plugs,Machine/NF screws etc complete as per direction of Engineer-in-charge.16 Way | Each | 346.92 | 346.92 | 6.0 | False | None | None | False | None | False | 2081.52 | 0 |
3544834 | 128035 | None | NUR100 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cuttinginBrick/C.Cwall,including necessary rawl plugs,Machine/NF screws etc., complete as per direction of Engineer-in-charge.18 Way | Each | 400.02 | 400.02 | 8.0 | False | None | None | False | None | False | 3200.16 | 0 |
3544835 | 128035 | None | NUR101 | Supplying and fixing superior quality modular switch mounting polycarbonateplate with necessary supporting back plate with required nos.of machine screws,boltsnutsetc.,complete on the existing metal/PVC box.As per direction of Engineer-in-charge.3 Module | Each | 189.98 | 189.98 | 4.0 | False | None | None | False | None | False | 759.92 | 0 |
3544836 | 128035 | None | NUR102 | Supplying and fixing superior quality modular switch mounting polycarbonateplate with necessary supporting back plate with required nos.of machine screws,boltsnutsetc.,complete on the existing metal/PVC box. As per direction of Engineer-in-charge. 8 Module | Each | 335.12 | 335.12 | 4.0 | False | None | None | False | None | False | 1340.48 | 0 |
3544837 | 128035 | None | NUR103 | Supplying and fixing superior quality modular switch mounting polycarbonateplate with necessary supporting back plate with required nos.of machine screws,boltsnutsetc.,complete on the existing metal/PVC box. As per direction of Engineer-in-charge.18 Module | Each | 539.26 | 539.26 | 4.0 | False | None | None | False | None | False | 2157.04 | 0 |
3544838 | 128035 | None | NUR104 | Supplying and fixing of modular switch andconnected accessories on existing modular switch plate as per IS 3854 and IS 1293 and As per direction of Engineer-in-charge.6A One Way Switch | Each | 120.36 | 120.36 | 5.0 | False | None | None | False | None | False | 601.8 | 0 |
3544839 | 128035 | None | NUR105 | Supplying and fixing of modular switch andconnected accessories on existing modular switch plate as per IS 3854 and IS 1293 and As per direction of Engineer-in-charge. 6A Two Way Switch | Each | 195.88 | 195.88 | 3.0 | False | None | None | False | None | False | 587.64 | 0 |
3544840 | 128035 | None | NUR106 | Supplying and fixing of modular switch andconnected accessories on existing modular switch plate as per IS 3854 and IS 1293 and As per direction of Engineer-in-charge.TV/Telephone SockeT | Each | 184.08 | 184.08 | 4.0 | False | None | None | False | None | False | 736.32 | 0 |
3544841 | 128035 | None | NUR107 | Supplying and fixing of modular switch andconnected accessories on existing modular switch plate as per IS 3854 and IS 1293 and as per direction of Engineer-in-charge. Stepped Fan Regulator Two Module | Each | 421.26 | 421.26 | 4.0 | False | None | None | False | None | False | 1685.04 | 0 |
3544842 | 128035 | None | NUR108 | Supplying and fixing of modular switch andconnected accessories on existing modular switch plate as per IS 3854 and IS 1293 and as per direction of Engineer-in-charge. 32A DP Switch | Each | 384.68 | 384.68 | 4.0 | False | None | None | False | None | False | 1538.72 | 0 |
3544843 | 128035 | None | NUR109 | Supplying of recess mounting non integrated type LED downlight......Wluminaire comprising of pressuredcast /extrudedaluminium housing,with spring load edfalseceiling clamps, LEDofPower /COBwithCCT6500degreeK,CRIgreater 70percent.efficacygreater100lumenperW,120degree beam spread,lifegreater25000burning hoursand Compliance to IS10322 /IEC60598, LM79andLM80 .The lamp compartment is enclosed with antiglareopal diffuser which enhance sthelighting level .LED 'sare driven by HF electro nicdriver integrated inaseparate control gear assembly.,withPFgreater0.95,powerlossshouldLesser5percentoflamp Wage, shortcircuitandopencircuit protection to beintegrated in the circuit, THD lessthan20percent,Life as per LM79.The operatinginputvoltageshouldbebetween130to275V.BISApproved and ested byNABL/CPRI accredited laboratory with 2years Warranty against any manufacturing defect working under standard electrical condition. As per direction of Engineer-in-charge.24 W | Each | 2044.94 | 2044.94 | 8.0 | False | None | None | False | None | False | 16359.52 | 0 |
3544844 | 128035 | None | NUR110 | Supplying capacitortype ceiling fan complete with down rod blades,shackle,canopiesetcfor operationon230V,50cycles.SinglephaseACsupplyconformingtoISS-374-1979andwith doubleballbearingsystem, as per direction of Engineer-in-charge.56 Sweep (1400 mm) Regular model | Each | 3576.58 | 3576.58 | 8.0 | False | None | None | False | None | False | 28612.64 | 0 |
3544845 | 128035 | None | NUR111 | Supplying exhaust fan of1440RPM of 300mm(12)size with bracket blades complete for light duty suitable to operateon230V50Hz, AC Supply and as per direction of Engineer-in-charge. | Each | 1760.55 | 1760.55 | 5.0 | False | None | None | False | None | False | 8802.75 | 0 |
3544846 | 128035 | None | NUR112 | Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-PrioritySource Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers and Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V and as per direction of Engineer-in-charge. 200 A | Each | 109922.9 | 109922.9 | 1.0 | False | None | None | False | None | False | 109922.9 | 0 |
3544847 | 128035 | None | NUR113 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., withprovision for fixing suitable type capacity MCB's single phase/3
phase/single door with powder coated painting Made out of 14SWG MS enclosure and as per direction of Engineer-in-charge.III - Double Door 16 Way SP and N | Each | 12266.1 | 12266.1 | 2.0 | False | None | None | False | None | False | 24532.2 | 0 |