| 3541017 | 127817 | None | ITEM01 | Earth work excavation for foundation of structure upto 3 mtrs. By mechanicle means as per drawing andtechnical specification, including setting out, providing shoring, strutting and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, filling back the excavated earth to the extent required and utilising / transporting the remaining earth upto 1.00km lead. including cost of labour, materials and HOM of machineries etc., completeOrdinary/Hard Soil. In all kinds of soils Depth upto 3 m ( CM SR 2021-22 P.No.
8/Vol-1/1.14.1) | Cum | 104.69 | 104.69 | 30.93 | False | None | None | False | None | False | 3238.0617 | 0 |
| 3541018 | 127817 | None | ITEM02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machinemixed, laid in layers not exceeding 150 mmthickness, well compacted using plate vibrators, including all lead & lifts, cost ofall materials ofquality, labour, Usage charges ofmachineries, curing, and all the otherappurtenances required to complete the work as pertechnical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse
aggregates(CMSR2021-22P.No.15/Vol-1/2.1.3) | Cum | 6750.3 | 6750.3 | 2.89 | False | None | None | False | None | False | 19508.367 | 0 |
| 3541019 | 127817 | None | ITEM03 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machinemixed, laid in layers not exceeding 150 mmthickness, well compacted using plate vibrators, including all lead & lifts, cost ofall materials ofquality, labour, Usage charges ofmachineries, curing, and all the otherappurtenances required to complete the work as pertechnical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates( CM SR 2021- 22 P.No.15/Vol-1/2.1.2 ) | Cum | 6327.37 | 6327.37 | 3.89 | False | None | None | False | None | False | 24613.4693 | 0 |
| 3541020 | 127817 | None | ITEM04 | Providing Size Stone masonrywith hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)(CM SR 2021-22/P.No.9/Vol-2/5.4) | Cum | 6504.82 | 6504.82 | 8.62 | False | None | None | False | None | False | 56071.5484 | 0 |
| 3541021 | 127817 | None | ITEM05 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)(CM SR 2021-22/P.No.15/Vol-1/2.2.2.1) | Cum | 7848.22 | 7848.22 | 5.4 | False | None | None | False | None | False | 42380.388 | 0 |
| 3541022 | 127817 | None | ITEM06 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)(CM SR 2021-22/P.No.15/Vol-1/2.2.2.1) | Cum | 12353.69 | 12353.69 | 0.54 | False | None | None | False | None | False | 6670.9926 | 0 |
| 3541023 | 127817 | None | ITEM07 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork tobe paid separately) M25 Design MixUsing 20 mmnominal size gradedcrushedcoarseaggregates(CMSR2021-22/P.No.17/Vol-1/2.5.2) | Cum | 12781.39 | 12781.39 | 1.49 | False | None | None | False | None | False | 19044.2711 | 0 |
| 3541024 | 127817 | None | ITEM08 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork tobe paid separately) M25 Design MixUsing 20 mmnominal size graded crushed coaSDe aggregates (CM SR 2021-22/P.No.17/Vol-1/2.5.2) | Cum | 12029.54 | 12029.54 | 3.45 | False | None | None | False | None | False | 41501.913 | 0 |
| 3541025 | 127817 | None | ITEM09 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork tobe paid separately) M25 Design MixUsing 20 mmnominal size graded crushed coarse aggregates (CM SR 2021-22/P.No.17/Vol-1/2.5.2) | Cum | 11277.69 | 11277.69 | 9.89 | False | None | None | False | None | False | 111536.3541 | 0 |
| 3541026 | 127817 | None | ITEM10 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork tobe paid separately) M25 Design MixUsing 20 mmnominal size graded crushed coarse aggregates (CM SR 2021-22/P.No.17/Vol-1/2.5.2) | Cum | 10901.77 | 10901.77 | 0.35 | False | None | None | False | None | False | 3815.6195 | 0 |
| 3541027 | 127817 | None | ITEM11 | Providing Thermo-Mechanically Treated baSD of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (CM SR 2021-22/P.No.84/Vol-2/11.32) | Kg | 116.67 | 116.67 | 2588.0 | False | None | None | False | None | False | 301941.96 | 0 |
| 3541028 | 127817 | None | ITEM12 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer byramming and watering, lead up to 50 m and lift upto 1.5 m. (CM SR 2021-22/P.No.115/Vol-1/1.9) Filling. | Cum | 247.94 | 247.94 | 33.39 | False | None | None | False | None | False | 8278.7166 | 0 |
| 3541029 | 127817 | None | ITEM13 | Providing Brick work with common burnt claymodular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (CM SR 2021-22/P.No.13/Vol-2/6.4) | Cum | 9009.76 | 9009.76 | 10.61 | False | None | None | False | None | False | 95593.5536 | 0 |
| 3541030 | 127817 | None | ITEM14 | Providing 20 mmcement plaster of mix:1:4 (1 cement: 4 fine sand) tobrick/stone masonaryincluding rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost ofmaterials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (CM SR 2021- 22/P.No.41/Vol-2/8.3.1) Upto 3.50m | Sqm | 363.4 | 363.4 | 90.78 | False | None | None | False | None | False | 32989.452 | 0 |
| 3541031 | 127817 | None | ITEM15 | Providing 15 mmcement plaster on the rough side of single or half brick wall of mix1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in- charge. (CM SR 2021-22/P.No.41/Vol-2/8.2.1) Upto 3.50m | Sqm | 301.41 | 301.41 | 25.32 | False | None | None | False | None | False | 7631.7012 | 0 |
| 3541032 | 127817 | None | ITEM16 | Providing 12 mmcement plaster finished with a floating coat of neat cement of mix:1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. for Ceiling. (CM SR 2021-22/P.No.41/Vol-2/8.4.1) | Sqm | 333.01 | 333.01 | 44.12 | False | None | None | False | None | False | 14692.4012 | 0 |
| 3541033 | 127817 | None | ITEM17 | Providing and laying 52 mmthick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge.s (CM SR 2021-22/P.No.59/Vol-2/9.2) | Sqm | 856.85 | 856.85 | 15.84 | False | None | None | False | None | False | 13572.504 | 0 |
| 3541034 | 127817 | None | ITEM18 | Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified bythe manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).(CM SR 2021-22/P.No.63/Vol-2/9.21.2) Size of Tile 600x600 mm. | Sqm | 1395.27 | 1395.27 | 16.88 | False | None | None | False | None | False | 23552.1576 | 0 |
| 3541035 | 127817 | None | ITEM19 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round baSD etc. including priming coat with approved steel primer all complete. Fixed to steel windows bywelding (CM SR 2021-22/P.No.85/Vol-2/11.34A) | Sqm | 159.21 | 159.21 | 181.44 | False | None | None | False | None | False | 28887.0624 | 0 |
| 3541036 | 127817 | None | ITEM20 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in- charge Upto 3.50 m (CM SR 2021-22/P.No.46/Vol-2/8.33.1) | Sqm | 143.41 | 143.41 | 69.44 | False | None | None | False | None | False | 9958.3904 | 0 |
| 3541037 | 127817 | None | ITEM21 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in- charge. Upto 3.50 m(CM SR 2021-22/P.No.46/Vol-2/8.33.1) | Sqm | 143.41 | 143.41 | 90.78 | False | None | None | False | None | False | 13018.7598 | 0 |
| 3541038 | 127817 | None | ITEM22 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats onnew work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (CM SR 2021-22/P.No.48/Vol-2/8.40) | Sqm | 111.8 | 111.8 | 11.34 | False | None | None | False | None | False | 1267.812 | 0 |
| 3541039 | 127817 | None | ITEM23 | KSRB 7.11 : Providing and fixing in position aluminium windows and ventilators as per approved drawings with sliding shutters using three track window frame of size 92x31.75mm bottom section 1.3mm thick, weight 1.07kg/m; sides and top sections 1.3 mm, thick, weight 0.933 kg/m.shutter frame section comprising top and bottom section of size 40mmx18mm, wall thickness 1.25mm. weight 0.417 kg./m. shutter side outer 40mmx18mm. wall thickness 1.25mm. weight 0.417 kg/m, shutter interlock section 40mmx26.7mm wall thickness 1.1 mm. thick, weight 0.469 kg/m, the shutters mounted on nylon rollers with approved quality of fixtures such as aluminium handles tower bolts etc.; providing and fixing 5.5mm. thick plain glass for shutters fitted with rubber beading all aluminium sections including cutting to required length, joints mitred subdividing the frame tenonned and rivetted, in the assembled frame, stiffened with end clips for corners, angles etc., andfixed to the walls, lintels, floor beams/cills as the case may be, with necessary steel screws, raul plugs or teak wood gatties including cutting masonry or concrete and making good the original surface using cement mortar. using aluminium section powdered coated to a minimum of 60-70 microns with exterior durable pure polyester grade powder of approved quality. (PWD SR 2018-19/P.No.35/7.11.1) | Sqm | 5436.4 | 5436.4 | 10.44 | False | None | None | False | None | False | 56756.016 | 0 |
| 3541040 | 127817 | None | ITEM24 | Providing and fixing on wall face unplastcised Rigid PVC rain water pipes confirming to IS:13592 Type A, including jointing with seal ring confirming to IS:5382, leaving 10mm gap for thermal expansion,(i) single socketed pipes 100mm diameter. ( CM SR 2021-22 P.No. 119/Vol-2/ 13.48) | Mtr | 307.49 | 307.49 | 11.25 | False | None | None | False | None | False | 3459.2625 | 0 |
| 3541041 | 127817 | None | ITEM25 | Supplyingof.....feet-PVCBattenwithintegratedLEDtube | Each | 873.19 | 873.19 | 2.0 | False | None | None | False | None | False | 1746.38 | 0 |
| 3541042 | 127817 | None | ITEM26 | Supplyof round/squarerecess/surfacemounted rollingtypeLED Down light with | Each | 644.28 | 644.28 | 4.0 | False | None | None | False | None | False | 2577.12 | 0 |
| 3541043 | 127817 | None | ITEM27 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc | Each | 2460.29 | 2460.29 | 2.0 | False | None | None | False | None | False | 4920.58 | 0 |
| 3541044 | 127817 | None | ITEM28 | Fixingalltypesandallcapacitiesoffluorescent/falseceiling/
spotlight/CFL/LEDfittingsindooronthewall/ceiling/rafters
/girdersusing23/0.0076"twintwistedPVCinsulatedwires, | Each | 140.42 | 140.42 | 8.0 | False | None | None | False | None | False | 1123.36 | 0 |
| 3541045 | 127817 | None | ITEM29 | Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clA and 'S' hook made out of 15mm dia MS rod, with 5 A. ceilingroseof approved qualitywith necessarylength of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. | Each | 331.58 | 331.58 | 2.0 | False | None | None | False | None | False | 663.16 | 0 |
| 3541046 | 127817 | None | ITEM30 | SupplyingheavygaugePVC conduitpipe............ mm
dia. ........ mm thickconfirming to IS2509withsuitable size bends, metal/PVC Junction boxes, adhesivepasteetc., and runningbefore concreting the slab. The conduit should be tied to thereinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary.
19/20mmdia2mm thick | Mtr | 71.97 | 71.97 | 75.0 | False | None | None | False | None | False | 5397.75 | 0 |
| 3541047 | 127817 | None | ITEM31 | SupplyingheavygaugePVCconduitpipe .......dia ............... mmthick confirming to IS 2509 with suitable size bends, junction boxes, adhesivepasteetc , and fixingusinginverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20 mm dia 2 mm thick | Mtr | 80.24 | 80.24 | 50.0 | False | None | None | False | None | False | 4012.0 | 0 |
| 3541048 | 127817 | None | ITEM32 | Supplying PVC/GI flexible conduitpipe .......mmdiafixingon surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped usingheavygaugesaddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely. 20mm | Mtr | 29.5 | 29.5 | 20.0 | False | None | None | False | None | False | 590.0 | 0 |
| 3541049 | 127817 | None | ITEM33 | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent PolycarbonateLid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase
/ Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap openingfor operatingMCB alongwith completetamper proof SEALING facility. | Each | 7280.59 | 7280.59 | 1.0 | False | None | None | False | None | False | 7280.59 | 0 |
| 3541050 | 127817 | None | ITEM34 | Grounding of towers including cost of 40 mm dia 2.5 mm thick, class 'C' G.I. Pipeof 3 metres length as per specifications, with 50 X 6 mm GI Flats 3 metre long, saltcharcoal,includingexcavationcharges. | Set | 5841.0 | 5841.0 | 1.0 | False | None | None | False | None | False | 5841.0 | 0 |
| 3541051 | 127817 | None | ITEM35 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiringwith specified IS 694:confirmingtolatest amendments. 1.5 mm2 | Mtr | 30.68 | 30.68 | 250.0 | False | None | None | False | None | False | 7670.0 | 0 |
| 3541052 | 127817 | None | ITEM36 | Wiring for lighting/power circuit using one of FRLS PVCinsulated 1100V grade, multistrand copper wire with lowconductor resistance single core in open or concealed system of wiringwith specified IS-694:confirmingtolatest amendments. 2.5
mm2 | Mtr | 47.19 | 47.19 | 250.0 | False | None | None | False | None | False | 11797.5 | 0 |
| 3541053 | 127817 | None | ITEM37 | Wiring for lighting/power circuit using one of FRLS PVCinsulated 1100V grade, multistrand copper wire with lowconductor resistance single core in open or concealed system of wiringwith specified IS-694:confirmingtolatest amendments. 4.0
mm2 | Mtr | 69.61 | 69.61 | 100.0 | False | None | None | False | None | False | 6961.0 | 0 |
| 3541054 | 127817 | None | ITEM38 | Supplyingand fixingPVC/metal conduit Deep junction box. 19/20mm deep junction box | Each | 57.82 | 57.82 | 12.0 | False | None | None | False | None | False | 693.84 | 0 |
| 3541055 | 127817 | None | ITEM39 | Supplying & fixing of Porcelain fuse channel with cut out on existingwooden/panel usingnecessarynuts, bolts and washers. 63 A | Each | 438.96 | 438.96 | 1.0 | False | None | None | False | None | False | 438.96 | 0 |
| 3541056 | 127817 | None | ITEM40 | FabricatingsupplyingandmountingMSboxmadeout
....SWG suitablefor floor /wall mounting, fullyweather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG | Sqm | 0.1 | 0.1 | 5000.0 | False | None | None | False | None | False | 500.0 | 0 |
| 3541057 | 127817 | None | ITEM41 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-
39756.4.5 3. | Mtr | 212.39 | 212.39 | 20.0 | False | None | None | False | None | False | 4247.8 | 0 |
| 3541058 | 127817 | None | ITEM42 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V upto 300mA sensitivityon existing wood/panel board.16-25 A 2 pole | Each | 2992.48 | 2992.48 | 1.0 | False | None | None | False | None | False | 2992.48 | 0 |
| 3541059 | 127817 | None | ITEM43 | Supplyingand fixingMoulded CaseCircuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete.
Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS- 13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carryingpath with thefront cover open). Multi-polebreakers shall be designed to break all the
poles simultaneouslyand theyshall havea singlemechanism. 100 A 25 kA | Each | 9752.69 | 9752.69 | 1.0 | False | None | None | False | None | False | 9752.69 | 0 |
| 3541060 | 127817 | None | ITEM44 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards usingnecessaryfixingmaterials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A DP | Each | 1301.54 | 1301.54 | 1.0 | False | None | None | False | None | False | 1301.54 | 0 |
| 3541061 | 127817 | None | ITEM45 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards usingnecessaryfixingmaterials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A TPN | Each | 2096.85 | 2096.85 | 1.0 | False | None | None | False | None | False | 2096.85 | 0 |
| 3541062 | 127817 | None | ITEM46 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards usingnecessaryfixingmaterials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirmingto IEC60898.6-32ASP | Each | 617.14 | 617.14 | 1.0 | False | None | None | False | None | False | 617.14 | 0 |
| 3541063 | 127817 | None | ITEM47 | Supplying and fixing surface/flush mounting unbreakable PVC modular boxsuitablefor mountingmodular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 1-3 way | Each | 107.38 | 107.38 | 2.0 | False | None | None | False | None | False | 214.76 | 0 |
| 3541064 | 127817 | None | ITEM48 | Supplying and fixing surface/flush mounting unbreakable PVC modular boxsuitablefor mountingmodular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4-5 way | Each | 143.95 | 143.95 | 2.0 | False | None | None | False | None | False | 287.9 | 0 |
| 3541065 | 127817 | None | ITEM49 | Supplying and fixing surface/flush mounting unbreakable PVC modular boxsuitablefor mountingmodular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 way | Each | 175.82 | 175.82 | 2.0 | False | None | None | False | None | False | 351.64 | 0 |
| 3541066 | 127817 | None | ITEM50 | Supplying and fixing surface/flush mounting unbreakable PVC modular boxsuitablefor mountingmodular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 8 way | Each | 230.1 | 230.1 | 2.0 | False | None | None | False | None | False | 460.2 | 0 |
| 3541067 | 127817 | None | ITEM51 | Supplying and flush mounting powder coated / galvanized metal boxsuitablefor mountingmodular switch plates. Theboxshould be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 1-3 way | Each | 145.14 | 145.14 | 2.0 | False | None | None | False | None | False | 290.28 | 0 |
| 3541068 | 127817 | None | ITEM52 | Supplying and flush mounting powder coated / galvanized metal boxsuitablefor mountingmodular switch plates. Theboxshould be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 4-5 way | Each | 162.84 | 162.84 | 2.0 | False | None | None | False | None | False | 325.68 | 0 |
| 3541069 | 127817 | None | ITEM53 | Supplying and flush mounting powder coated / galvanized metal boxsuitablefor mountingmodular switch plates. Theboxshould be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 6 way | Each | 250.16 | 250.16 | 2.0 | False | None | None | False | None | False | 500.32 | 0 |
| 3541070 | 127817 | None | ITEM54 | Supplying and flush mounting powder coated / galvanized metal boxsuitablefor mountingmodular switch plates. Theboxshould be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 8 way | Each | 295.0 | 295.0 | 2.0 | False | None | None | False | None | False | 590.0 | 0 |
| 3541071 | 127817 | None | ITEM55 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machinescrews, bolts nuts etc., completeon the existing metal/PVC box. 1-3 Module | Each | 179.35 | 179.35 | 2.0 | False | None | None | False | None | False | 358.7 | 0 |
| 3541072 | 127817 | None | ITEM56 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machinescrews, bolts nuts etc., completeon the existing metal/PVC box. 4 Module | Each | 206.5 | 206.5 | 2.0 | False | None | None | False | None | False | 413.0 | 0 |
| 3541073 | 127817 | None | ITEM57 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machinescrews, bolts nuts etc., completeon the existing metal/PVC box. 6 Module | Each | 287.91 | 287.91 | 2.0 | False | None | None | False | None | False | 575.82 | 0 |
| 3541074 | 127817 | None | ITEM58 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machinescrews, bolts nuts etc., completeon the existing metal/PVC box. 8 Module | Each | 356.35 | 356.35 | 2.0 | False | None | None | False | None | False | 712.7 | 0 |
| 3541075 | 127817 | None | ITEM59 | Supplyingand fixingof modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
SteppedFanRegulatorTwoModule | Each | 369.34 | 369.34 | 2.0 | False | None | None | False | None | False | 738.68 | 0 |
| 3541076 | 127817 | None | ITEM60 | Supplyingand fixingof modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6/16AUniversalSocket | Each | 293.82 | 293.82 | 40.0 | False | None | None | False | None | False | 11752.8 | 0 |
| 3541077 | 127817 | None | ITEM61 | Supplyingand fixingof modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
TV/TelephoneSocket | Each | 173.45 | 173.45 | 1.0 | False | None | None | False | None | False | 173.45 | 0 |
| 3541078 | 127817 | None | ITEM62 | Supplyingand fixingof modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
RJ45/I.OOutletCat-6 | Each | 248.98 | 248.98 | 1.0 | False | None | None | False | None | False | 248.98 | 0 |
| 3541079 | 127817 | None | ITEM63 | Supplyingand drawingPVC flexibleonepair telephone unarmoured tinned copper cable-1 pair | Mtr | 15.34 | 15.34 | 30.0 | False | None | None | False | None | False | 460.2 | 0 |