createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1721023954623
version7
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee2610.00
emd200000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose26-07-2024 16:00:00
tenderQueryClose24-07-2024 17:30:00
technicalBidOpen29-07-2024 11:30:00
publishedDate19-07-2024 13:07:08
publishedByPostPWD_EE_DIV_YDG
publishedByUserKPE12547 - ABHIMANYA K S
bidValidityPeriod90
noOfCalls1
preBidMeetingDate22-07-2024 11:30:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonABHIMANYA K S
splitEmdRequiredYnTrue
emdBankGuarantee100000.00
emdCash100000.00
bgValidityPeriod90
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08473252470
mobileNumber9448456958
tenderSupplierListNone
tenderSchedule
createdTs1721023954658
version10
createdDateNone
modifiedDateNone
tenderNumberPWD/2024-25/BD/WORK_INDENT11254
titleConstruction of New Balabhavan Building in Shorapur Town, District Yadgiri (Under KKRDB Micro(SCP) for the year 2023-24) (Work Code YAD231523128)
descriptionConstruction of New Balabhavan Building in Shorapur Town, District Yadgiri (Under KKRDB Micro(SCP) for the year 2023-24) (Work Code YAD231523128)
categoryWORKS
categoryTextWorks
ecv10431005.90
deptNamePublic Works Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location1691
locationNamePWD Division Office Yadagiri
provisionalAmount12313000.0
groupOverheadTotal0.0
fileNumberPWD/SD/SHOR/KKRDB/2024-25/11
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17210239550000NoneNoneBuildingsGround Floor9401441.5
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3523890126626NoneP:8, I.No 1.12. PWD SR 2023-24 Volume 1Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.Cum99.7599.7512.6FalseNoneNoneFalseNoneFalse1256.850
3523891126626NoneP:8, I.No 1.14 PWD SR 2023-24 Volume 1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 mCum107.1107.1195.86FalseNoneNoneFalseNoneFalse20976.6060
3523892126626NoneP:8, I.No 1.14.2 PWD SR 2023-24 Volume 1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth 3 m to 6 mCum122.85122.8538.43FalseNoneNoneFalseNoneFalse4721.12550
3523893126626NoneP:15, I.No 2.1.4 PWD SR 2023-24 Volume 1 Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCum6527.856527.8568.93FalseNoneNoneFalseNoneFalse449964.70050
3523894126626NoneP:15, I.No 2.2.1 PWD SR 2023-24 Volume 1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6601.356601.3549.27FalseNoneNoneFalseNoneFalse325248.51450
3523895126626NoneVol-I S R Sl no. 1 (a) Page No. 111Addendum I-Percentage Additionalities for Formwork, Centering & Scaffolding for Foundation upto Plinth Isolated add 8%Cum528.11528.1149.27FalseNoneNoneFalseNoneFalse26019.97970
3523896126626NoneP:16, I.No 2.5.2 PWD SR 2023-24 Volume 1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7185.157185.1532.85FalseNoneNoneFalseNoneFalse236032.17750
3523897126626NoneVol-I S R Sl No. 9 Page No 111Addendum I-Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Columns / Shaft (Slip Centering) add 70%Cum5029.65029.632.85FalseNoneNoneFalseNoneFalse165222.360
3523898126626NoneP:16, I.No 2.5.2 PWD SR 2023-24 Volume 1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7185.157185.1516.79FalseNoneNoneFalseNoneFalse120638.66850
3523899126626NoneVol-I S R Sl no. 2 Page No. 111Addendum I-Percentage Additionalities for Formwork, Centering & Scaffolding for Plinth Beams of Buildings add 50%Cum3592.573592.5716.79FalseNoneNoneFalseNoneFalse60319.25030
3523900126626NoneP:16, I.No 2.5.2 PWD SR 2023-24 Volume 1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7185.157185.1532.28FalseNoneNoneFalseNoneFalse231936.6420
3523901126626NoneVol-I S R Sl no. 14 Page No. 112Addendum I-Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts add 60%Cum4311.094311.0932.28FalseNoneNoneFalseNoneFalse139161.98520
3523902126626NoneP:16, I.No 2.5.2 PWD SR 2023-24 Volume 1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7185.157185.1564.93FalseNoneNoneFalseNoneFalse466531.78950
3523903126626NoneVol-I S R Sl no. 15 Page No. 112Addendum I-Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Roof Slabs add 50%Cum3592.573592.5764.93FalseNoneNoneFalseNoneFalse233265.57010
3523904126626NoneP:16, I.No 2.5.2 PWD SR 2023-24 Volume 1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7185.157185.150.68FalseNoneNoneFalseNoneFalse4885.9020
3523905126626NoneVol-I S R Sl no. 19 Page no. 112Addendum I-Percentage Additionalities for Formwork, Centering & Scaffolding for Chejjas, Canopy & Other Architectural projections of minor sections add 45%Cum3233.323233.320.68FalseNoneNoneFalseNoneFalse2198.65760
3523906126626NoneVol-I I No. 2.11 (a) Page No. 18Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Buildingst93929.8593929.8523.61FalseNoneNoneFalseNoneFalse2217683.75850
3523907126626NoneVol-II I No 5.3 Page No 9Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6515.256515.2538.65FalseNoneNoneFalseNoneFalse251814.41250
3523908126626NoneVol-II I No. 5.4 Page No. 9Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.4515.81FalseNoneNoneFalseNoneFalse106060.59450
3523909126626NoneVol-I I No. 1.11 Page no. 7Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum454.65454.65448.41FalseNoneNoneFalseNoneFalse203869.60650
3523910126626NoneVol-II INo 6.8 Page No. 14Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8367.458367.45122.95FalseNoneNoneFalseNoneFalse1028777.97750
3523911126626NoneVol-II I No. 6.15 Page No. 14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workSqm1084.651084.65129.98FalseNoneNoneFalseNoneFalse140982.8070
3523912126626NoneVol-II I No. 12.13.1 Page No. 100Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum103755.75103755.750.87FalseNoneNoneFalseNoneFalse90267.50250
3523913126626NoneVol-II I No. 12.15 Page No. 100Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures )Sqm7816.27816.230.72FalseNoneNoneFalseNoneFalse240113.6640
3523914126626NoneVol-II I No. 12.55.1 Page No. 104Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. with both side prelamSqm2484.32484.310.8FalseNoneNoneFalseNoneFalse26830.440
3523915126626NoneVol-II I No. 11.34B Page No. 86Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.Kg192.15192.15657.72FalseNoneNoneFalseNoneFalse126380.8980
3523916126626NoneVol-II I No. 11.35.1.1 Page No. 87Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications.Kg474.6474.6259.2FalseNoneNoneFalseNoneFalse123016.320
3523917126626NoneVol-II I no. 11.30.1 Page No. 85Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.Sqm957.6957.69.72FalseNoneNoneFalseNoneFalse9307.8720
3523918126626NoneVol-II I No. 11.28 Page No. 85Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg593.25593.2589.0FalseNoneNoneFalseNoneFalse52799.250
3523919126626NoneVol-II I No. 8.1.1 Page No. 41Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm267.75267.75519.29FalseNoneNoneFalseNoneFalse139039.89750
3523920126626NoneVol-II I No. 8.2.1 Page No. 41Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm309.75309.75980.33FalseNoneNoneFalseNoneFalse303657.21750
3523921126626NoneVol-II I No. 8.3.1 Page No. 41Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm371.7371.7596.08FalseNoneNoneFalseNoneFalse221562.9360
3523922126626NoneVol-II I No. 8.19.2 Page No. 44Providing Raised and cut pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge.Sqm486.15486.1554.38FalseNoneNoneFalseNoneFalse26436.8370
3523923126626NoneVol-II I No. 9.17.5 Page No. 61Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x1200 mmSqm1411.21411.2465.32FalseNoneNoneFalseNoneFalse656659.5840
3523924126626NoneVol-II I No. 9.30 Page No. 64Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specificationsSqm5594.45594.430.75FalseNoneNoneFalseNoneFalse172027.80
3523925126626NoneVol-II I No. 9.11 Page No. 60Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.Sqm933.45933.4521.68FalseNoneNoneFalseNoneFalse20237.1960
3523926126626NoneVol-II I No. 9.39 Page No. 65Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.Sqm1521.451521.45117.51FalseNoneNoneFalseNoneFalse178785.58950
3523927126626NoneVol-II I No. 8.51 Page No. 50Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm105.0105.01382.11FalseNoneNoneFalseNoneFalse145121.550
3523928126626NoneVol-II I No. 8.27 Page No. 45Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm55.6555.651382.11FalseNoneNoneFalseNoneFalse76914.42150
3523929126626NoneVol-II I No. 8.39 Page No. 48Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm133.35133.351382.11FalseNoneNoneFalseNoneFalse184304.36850
3523930126626NoneVol-II I No. 8.30 Page No. 46Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm182.7182.7650.46FalseNoneNoneFalseNoneFalse118839.0420
3523931126626NoneVol-II I No. 8.33.2 Page No. 46Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @0.75 L/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm144.9144.970.66FalseNoneNoneFalseNoneFalse10238.6340
3523932126626NoneVol-II I No. 8.33.3 Page No. 47Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm145.95145.9559.4FalseNoneNoneFalseNoneFalse8669.430
3523933126626NoneVol-II I No. 11.5.2 Page No. 77Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm4454.14454.11.89FalseNoneNoneFalseNoneFalse8418.2490
3523934126626NoneVol-II I No. 11.16.1 Page No. 82Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg142.8142.857.76FalseNoneNoneFalseNoneFalse8248.1280
3523935126626NoneVol-II I No. 7.1.1 Page No. 20Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge 0.63 mm thick with zinc coating not less than 275 g/ m²Sqm922.95922.9517.33FalseNoneNoneFalseNoneFalse15994.72350
17210239550000NoneNoneBuildingsWater Supply and Sanitation397599.72
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3523936126627NoneP:131, I.No 14.2.2 PWD SR 2023-24 Volume 2Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C.flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked black solid plastic seat and lidEach5076.755076.752.0FalseNoneNoneFalseNoneFalse10153.50
3523937126627NoneP:131, I.No 14.1.1 PWD SR 2023-24 Volume 2Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot restsEach5128.25128.24.0FalseNoneNoneFalseNoneFalse20512.80
3523938126627NoneP:132, I.No 14.7.1 PWD SR 2023-24 Volume 2Providing and fixing wash basin with C.I. brackets, 15 mm PTMT pillar cock, 32 mm PTMT waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar tapsEach3236.13236.110.0FalseNoneNoneFalseNoneFalse32361.00
3523939126627NoneP:110, I.No 13.8.2.2 PWD SR 2023-24 Volume 2Providing and fixing unplasticised PVC connection pipe with brass unions : 45 cm length 20 mm nominal boreEach115.5115.510.0FalseNoneNoneFalseNoneFalse1155.00
3523940126627NoneP:137, I.No 14.37.1 PWD SR 2023-24 Volume 2Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gmsEach321.3321.310.0FalseNoneNoneFalseNoneFalse3213.00
3523941126627NoneP:117, I.No 13.2.2 PWD SR 2023-24 Volume 2Providing and fixing brass bib cock of approved quality : 20 mm nominal boreEach320.25320.2516.0FalseNoneNoneFalseNoneFalse5124.00
3523942126627NoneP:120, I.No 13.20.2 PWD SR 2023-24 Volume 2Providing and fixing PTMT pillar cock of approved quality and colour.15 mm nominal bore, 125 mm long foam flow, weighing not less than 120 gmsEach329.7329.710.0FalseNoneNoneFalseNoneFalse3297.00
3523943126627NoneP:117, I.No 13.5.2 PWD SR 2023-24 Volume 2Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal boreEach329.7329.71.0FalseNoneNoneFalseNoneFalse329.70
3523944126627NoneP:117, I.No 13.5.3 PWD SR 2023-24 Volume 2Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal boreEach348.6348.61.0FalseNoneNoneFalseNoneFalse348.60
3523945126627NoneP:115, I.No 13.4.2 PWD SR 2023-24 Volume 2Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32 mm nominal boreNo627.9627.91.0FalseNoneNoneFalseNoneFalse627.90
3523946126627NoneP: 123, I.No 13.34 PWD SR 2023-24 Volume 2 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tankLtr9.459.452000.0FalseNoneNoneFalseNoneFalse18900.00
3523947126627NoneP: 122, I.No 13.32.3 PWD SR 2023-24 Volume 2 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipesm500.85500.85150.0FalseNoneNoneFalseNoneFalse75127.50
3523948126627NoneP: 122, I.No 13.33.4 PWD SR 2023-24 Volume 2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 32 mm nominal dia Pipesm390.6390.6100.0FalseNoneNoneFalseNoneFalse39060.00
3523949126627NoneP:113, I.No 10.1.8 PWD SR 2023-24 Volume VProviding PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 140mm dia., 6 kg/sqcm & class 3m613.2613.280.0FalseNoneNoneFalseNoneFalse49056.00
3523950126627NoneP:113, I.No 10.1.7 PWD SR 2023-24 Volume VProviding PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 110mm dia., 6 kg/sqcm & class 3m431.55431.55100.0FalseNoneNoneFalseNoneFalse43155.00
3523951126627NoneP:113, I.No 10.1.5 PWD SR 2023-24 Volume VProviding PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 75mm dia., 6 kg/sqcm & class 3m231.0231.077.0FalseNoneNoneFalseNoneFalse17787.00
3523952126627NoneP:8, I.No 1.14.1 PWD SR 2023-24 Volume 1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 mCum107.1107.197.2FalseNoneNoneFalseNoneFalse10410.120
3523953126627NoneP:7, I.No 1.10 PWD SR 2023-24 Volume 1Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specificationsCum168.0168.081.0FalseNoneNoneFalseNoneFalse13608.00
3523954126627NoneP:191, I.No 16.10 PWD SR 2023-24 Volume VConstructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and coverEach4447.84447.812.0FalseNoneNoneFalseNoneFalse53373.60
17210239550000NoneNoneBuildingsSinking of Borewell241146.15
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3523955126628NoneV-5, Pg. No.140, Item.No:12.4Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. etc. completeEach5552.45552.41.0FalseNoneNoneFalseNoneFalse5552.40
3523956126628NoneVol-V I No. 12.1.1 Page No. 139Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 0 to 50 Mtrsm388.5388.550.0FalseNoneNoneFalseNoneFalse19425.00
3523957126628NoneVol-V I No. 12.1.2 Page No. 139Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 50 to 100 Mtrsm487.2487.250.0FalseNoneNoneFalseNoneFalse24360.00
3523958126628NoneVol-V I No. 12.32 Page No. 143Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty.m2029.652029.6512.0FalseNoneNoneFalseNoneFalse24355.80
3523959126628NoneVol-V I No. 10.1.9 Page No. 113Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 160mm dia., 6 kg/sqcm & class 3m648.9648.9102.0FalseNoneNoneFalseNoneFalse66187.80
3523960126628NoneVol-V I No. 9.1.4 Page No. 95Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 HDPE Grade PE80-PN6.0,110mm diam492.45492.4595.0FalseNoneNoneFalseNoneFalse46782.750
3523961126628NoneVol-V I No. 13.11.5 Page No. 151Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For 3 HP etc. complete 3.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00"Each29518.6529518.651.0FalseNoneNoneFalseNoneFalse29518.650
3523962126628NoneVol-V I No. 13.22.2 Page No. 154Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x2.5 Sqmm89.2589.25105.0FalseNoneNoneFalseNoneFalse9371.250
3523963126628NoneVol-V I No. 13.23.2 Page No. 155Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete. 3 to 6 HP pumpsEach10027.510027.51.0FalseNoneNoneFalseNoneFalse10027.50
3523964126628NoneVol-V I No. 13.39 Page No. 157Earthing: Providing and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia.Job3937.53937.51.0FalseNoneNoneFalseNoneFalse3937.50
3523965126628NoneVol-V I No. 13.25.2 Page No. 154Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 65 mmEach1627.51627.51.0FalseNoneNoneFalseNoneFalse1627.50
17210239550000NoneNoneBuildingsElectrical work390818.53
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3523966126629NoneVol-VI I No. 1.2.1 Page No. 2 of 105Concealed Conduit System Supplying heavy gauge PVC conduit pipe 19/20mm dia 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessarym66.066.0110.0FalseNoneNoneFalseNoneFalse7260.00
3523967126629NoneVol-6 I No. 1.2.2 Page No. 2 of 102SupplyingheavygaugePVCconduitpipe.mmdia.mmthickconfirmingtoIS2509withsuitablesizebends,metal/PVCJunctionboxes,adhesivepasteetc.,andrunningbeforeconcretingtheslab.TheconduitshouldbetiedtothereinforcementrodsbyusingbindingwiresandunusedwaysofjunctionboxesandpipeendsshouldbecoveredusingPVCendenclosures,runwith18SWGGIfishwirewherever necessary 25 mm dia 2 mm thickm78.078.035.0FalseNoneNoneFalseNoneFalse2730.00
3523968126629NoneVol-6 I No 1.7.1 Page No. 3Extra for Groove cutting in brick wall / CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing up to wall surface complete. up to 50 mm conduit in brick wallm29.029.080.0FalseNoneNoneFalseNoneFalse2320.00
3523969126629None2.1.1SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingusing2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLSmultistrandPVCinsulatedcopperwire(confirmingtoIS-694:andlatestamendments)with a6AmpsflushtypeSPcontrolswitchshallbefixedontheexistingplasticsheet/gangbox,theotherendofthewiresshallbeterminatedwithsufficientlooselengthinawood/PVCroundblock.completeforeach outlet. Short point upto 3Mtr from tapping point to out let via switchPoint285.0285.024.0FalseNoneNoneFalseNoneFalse6840.00
3523970126629None2.1.2SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingusing2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLSmultistrandPVCinsulatedcopperwire(confirmingtoIS-694:andlatestamendments)with a6AmpsflushtypeSPcontrolswitchshallbefixedontheexistingplasticsheet/gangbox,theotherendofthewiresshallbeterminatedwithsufficientlooselengthinawood/PVCroundblock.completeforeach outlet. Mediumpointabove3Mtrupto6MtrfromtappingpointtooutletviaswitchPoint394.0394.022.0FalseNoneNoneFalseNoneFalse8668.00
3523971126629None2.1.3SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingusing2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLSmultistrandPVCinsulatedcopperwire(confirmingtoIS-694:andlatestamendments)with a6AmpsflushtypeSPcontrolswitchshallbefixedontheexistingplasticsheet/gangbox,theotherendofthewiresshallbeterminatedwithsufficientlooselengthinawood/PVCroundblock.completeforeach outlet. Longpointabove6Mtrupto10MtrfromtappingpointtooutletviaswitchPoint570.0570.019.0FalseNoneNoneFalseNoneFalse10830.00
3523972126629None2.3.1Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 1 mm2m19.019.0195.0FalseNoneNoneFalseNoneFalse3705.00
3523973126629None2.3.2Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 1.5 mm2m26.026.0650.0FalseNoneNoneFalseNoneFalse16900.00
3523974126629None2.3.3Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 2.5 mm2m42.042.0255.0FalseNoneNoneFalseNoneFalse10710.00
3523975126629None2.3.4Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 4 mm2m63.063.0170.0FalseNoneNoneFalseNoneFalse10710.00
3523976126629None3.4.3Supplyingandflushmountingpowdercoated/galvanizedmetalboxsuitableformountingmodularswitchplates.Theboxshouldbefirmlyflush mounted after due groove cutting in Brick/Stone/C.C wall 4-5 WayEach177.0177.02.0FalseNoneNoneFalseNoneFalse354.00
3523977126629None3.4.4Supplyingandflushmountingpowdercoated/galvanizedmetalboxsuitableformountingmodularswitchplates.Theboxshouldbefirmlyflush mounted after due groove cutting in Brick/Stone/C.C wall 6 WayEach220.0220.02.0FalseNoneNoneFalseNoneFalse440.00
3523978126629None3.4.5Supplyingandflushmountingpowdercoated/galvanizedmetalboxsuitableformountingmodularswitchplates.Theboxshouldbefirmlyflush mounted after due groove cutting in Brick/Stone/C.C wall 8 WayEach261.0261.010.0FalseNoneNoneFalseNoneFalse2610.00
3523979126629None3.4.6Supplyingandflushmountingpowdercoated/galvanizedmetalboxsuitableformountingmodularswitchplates.Theboxshouldbefirmlyflush mounted after due groove cutting in Brick/Stone/C.C wall 10-12 WayEach319.0319.01.0FalseNoneNoneFalseNoneFalse319.00
3523980126629None3.4.8Supplyingandflushmountingpowdercoated/galvanizedmetalboxsuitableformountingmodularswitchplates.Theboxshouldbefirmlyflush mounted after due groove cutting in Brick/Stone/C.C wall 18 WayEach405.0405.04.0FalseNoneNoneFalseNoneFalse1620.00
3523981126629None3.5.3Supplyingandfixingsuperiorqualitymodularswitchmountingpolycarbonateplatewithnecessarysupportingbackplatewithrequirednos.ofmachinescrews,boltsnutsetc.,completeontheexistingmetal/PVC box. 4 ModuleEach175.0175.02.0FalseNoneNoneFalseNoneFalse350.00
3523982126629None3.5.4Supplyingandfixingsuperiorqualitymodularswitchmountingpolycarbonateplatewithnecessarysupportingbackplatewithrequirednos.ofmachinescrews,boltsnutsetc.,completeontheexistingmetal/PVC box. 6 ModuleEach234.0234.02.0FalseNoneNoneFalseNoneFalse468.00
3523983126629None3.5.5Supplyingandfixingsuperiorqualitymodularswitchmountingpolycarbonateplatewithnecessarysupportingbackplatewithrequirednos.ofmachinescrews,boltsnutsetc.,completeontheexistingmetal/PVC box. 8 ModuleEach284.0284.010.0FalseNoneNoneFalseNoneFalse2840.00
3523984126629None3.5.6Supplyingandfixingsuperiorqualitymodularswitchmountingpolycarbonateplatewithnecessarysupportingbackplatewithrequirednos.ofmachinescrews,boltsnutsetc.,completeontheexistingmetal/PVC box. 10-12 ModuleEach344.0344.01.0FalseNoneNoneFalseNoneFalse344.00
3523985126629None3.5.8Supplyingandfixingsuperiorqualitymodularswitchmountingpolycarbonateplatewithnecessarysupportingbackplatewithrequirednos.ofmachinescrews,boltsnutsetc.,completeontheexistingmetal/PVC box. 18 ModuleEach457.0457.04.0FalseNoneNoneFalseNoneFalse1828.00
3523986126629None3.6.1Supplyingandfixingofmodularswitch&connectedaccessoriesonexisting modular switch plate as per IS 3854 and IS 1293. 6A One Way SwitchEach102.0102.076.0FalseNoneNoneFalseNoneFalse7752.00
3523987126629None3.6.3Supplyingandfixingofmodularswitch&connectedaccessoriesonexisting modular switch plate as per IS 3854 and IS 1293. 6A Three Way socketEach171.0171.018.0FalseNoneNoneFalseNoneFalse3078.00
3523988126629None3.6.5Supplyingandfixingofmodularswitch&connectedaccessoriesonexisting modular switch plate as per IS 3854 and IS 1293. 400W DimmerEach276.0276.029.0FalseNoneNoneFalseNoneFalse8004.00
3523989126629None3.6.7Supplyingandfixingofmodularswitch&connectedaccessoriesonexisting modular switch plate as per IS 3854 and IS 1293. 16A One Way SwitchEach180.0180.08.0FalseNoneNoneFalseNoneFalse1440.00
3523990126629None3.6.10Supplyingandfixingofmodularswitch&connectedaccessoriesonexisting modular switch plate as per IS 3854 and IS 1293. 6/16A Universal SocketEach236.0236.08.0FalseNoneNoneFalseNoneFalse1888.00
3523991126629None3.14.5Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board. 6A Bakelite Ceiling RoseNo78.078.029.0FalseNoneNoneFalseNoneFalse2262.00
3523992126629None3.14.7Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board. 6A Batten HolderNo74.074.020.0FalseNoneNoneFalseNoneFalse1480.00
3523993126629None5.6.5Supplyandfixingpolishedwoodboardmadeofnotlessthan15mmthickplankonbothsidesofnotmorethan2piecesandfixingthesametothewallusingtaperedinvertedwoodenplugsscrews. 15" x 12" x 2"Each201.0201.01.0FalseNoneNoneFalseNoneFalse201.00
3523994126629None5.7.4Supplying&fixingofPorcelainfusechannelwithcutoutonexisting wooden/panel using necessary nuts, bolts and washers 100 AEach691.0691.04.0FalseNoneNoneFalseNoneFalse2764.00
3523995126629None5.15.9SupplyingandfixingMouldedCaseCircuitBreaker(MCCB)overtheexistingwood/panelboardusingnecessaryscrews,bolts,nuts,necessaryphaseseparators,handleandwiringcomplete.ProtectionofOverloadandShortcircuitwithadjustablethermalmagneticrelease,MicroprocessorreleaseshallhaveEarthFaultasperIS/IEC60947-2.(Icu=100%lcs).In4PMCCB,allPolesshouldhaveprotectionforShort-Cicrcuit/OverLoad.ForMicroprocessorMCCBSFacilityforsegregatingPriorityandNon-PriorityloadsmustbeavailableintheMCCB.MCCBshallbeprovidedwithdoubleinsulation(insulationbetweenfrontcoverandinternalpowercircuitstoavoidanyaccidentalcontactwithlivecurrentcarryingpathwiththefrontcoveropen).Multi-polebreakersshallbedesignedtobreakallthepolessimultaneously and they shall have a single mechanism. FOUR Pole 100 A 25 kAEach8487.08487.01.0FalseNoneNoneFalseNoneFalse8487.00
3523996126629None5.18.1Supplying&fixingminiaturecircuitbreakersonexistingMCBdistributionboardsusingnecessaryfixingmaterialsand'C'Typecurve,indicatorON/OFF,energycross-3withShortcircuitbreakingcapacityof10KandcompletewiringasrequiredconfirmingtoIEC60898.6-32 A SPEach415.0415.012.0FalseNoneNoneFalseNoneFalse4980.00
3523997126629None5.18.8Supplying&fixingminiaturecircuitbreakersonexistingMCBdistributionboardsusingnecessaryfixingmaterialsand'C'Typecurve,indicatorON/OFF,energycross-3withShortcircuitbreakingcapacityof10KandcompletewiringasrequiredconfirmingtoIEC60898. 40 A TPNEach3044.03044.04.0FalseNoneNoneFalseNoneFalse12176.00
3523998126629None5.19.9SupplyingandfixingregularMCBdistributionboardsonwall/oodboard/flushmountingusingrequiredclamps,bolts,nutsetc.,withprovisionforfixingsuitabletypecapacityMCB'ssinglephase/3phase/singledoorwithpowdercoatedpaintingMadeoutof14SWGMS enclosure. II - Double Door 12 Way SP & NEach2329.02329.02.0FalseNoneNoneFalseNoneFalse4658.00
3523999126629None5.29Supplying,fixingandwiring3PhaseDigitalAmmeter/VoltmeterEach1425.01425.01.0FalseNoneNoneFalseNoneFalse1425.00
3524000126629None5.35Supplying,fixingandwiringElectronicTrivectorMeter(ETV)5to32/63Athreephase4wirewholecurrentclass-1AccuracyEnergyMeter.Each5705.05705.01.0FalseNoneNoneFalseNoneFalse5705.00
3524001126629None5.38SupplyingandfixingofLEDtypepanelboardindicatinglampwith required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each515.0515.03.0FalseNoneNoneFalseNoneFalse1545.00
3524002126629None5.40.1Supplying.Arated3phasewithneutralbusbarusingrequiredcapacityelectrolyticaluminiumstripscoveredwithheatshrinkablecolouredPVCsleeve,mountedonphenolic/FRP/DMCinsulatorwhicharemountedonpowdercoated40x6mmM.S.flatframeworkinexistingpanelboard.ThebusbarshallhavesuitableholesforterminationofincomingandoutgoingcablesasperISspecification with necessary bolts, nuts and washers etc., complete 100 A 4 x 30 x 6 mm Aluminium Stripsm2465.02465.00.5FalseNoneNoneFalseNoneFalse1232.50
3524003126629None5.41.1SupplyingandfixingangleironframeworkfabricatedoutofM.S.angleiron.andM.S.Flat.withbolts,washersetc.,andpaintedwith 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mmm305.0305.06.0FalseNoneNoneFalseNoneFalse1830.00
3524004126629None5.42.2FabricatingsupplyingandmountingMSboxmadeout.SWGsuitableforfloor/wallmounting,fullyweatherproofwithprovisionforbetterheatdissipation,providedwithhingedfrontcover,equippedwithtamperprooflockingarrangements,withsuitablesizeclampswithnecessarycableentrypipewithglandandboxshouldbefinishedwith7tankstreatmentwithpowdercoatedpaintand finally finished with approved colour etc., complete 16 SWGSq CM0.430.4350000.0FalseNoneNoneFalseNoneFalse21500.00
3524005126629None6.1Supplyingexhaustfanof1440RPMof300mm(12")sizewithbracketbladescompleteforlightdutysuitabletooperateon230V50Hz, AC Supply.Each1492.01492.04.0FalseNoneNoneFalseNoneFalse5968.00
3524006126629None6.3.1Supplyingcapacitortypeceilingfancompletewithdownrodblades,shackle,canopiesetc,foroperationon230V,50cycles.SinglephaseACsupplyconformingtoISS-374-1979andwithdoubleballbearingsystem 48" Sweep (1200 mm) Regular modelEach2984.02984.027.0FalseNoneNoneFalseNoneFalse80568.00
3524007126629None13.10Fixingaceiling/Wallmountingfanofallcapacitiesandalltypestotheexisting'S''hookwithfanregulatortotheexistingboardtogetherwithsupplyingandfixing5A.ceilingrose,necessarylengthof23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each171.0171.027.0FalseNoneNoneFalseNoneFalse4617.00
3524008126629None11.3.2Supplyingof.feet-PVCBattenwithintegratedLEDtube.WwithhighqualitydiffuserwithLifeof25000burninghours&70%lumenmaintenancewithCRIGREATER THAN80.PowerInput:220-240V@50/60Hz&PowerfactorGREATER THAN0.9alongwithCEapproved.2yearsWarrantyagainstanymanufacturingdefectworkingunderstandardelectrical condition. LED light fitting 1 x 4' - 20/22 WEach690.0690.06.0FalseNoneNoneFalseNoneFalse4140.00
3524009126629None13.7.1Fixingalltypesandallcapacitiesoffluorescent/falseceiling/spotlight/CFL/LEDfittingsindooronthewall/ceiling/rafters/girdersusing23/0.0076"twintwistedPVCinsulatedwires,requiredNosofround blocks and clamps On wall/ ceiling / Rafter / GirdersEach122.0122.06.0FalseNoneNoneFalseNoneFalse732.00
3524010126629None11.9.2Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material,delivering superior light output. Rated life Burning Hrs 50000hr @ Lumen Maintenance of 70%, CCT greater than 5500K, IP 66optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiencygreater than 130lm/w, nominal CRI greater than75. Luminaire manufacturer should have inhouse facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/Lumileds /Osram make LED Source. LED Floodlight 100WEach9486.09486.08.0FalseNoneNoneFalseNoneFalse75888.00
3524011126629None13.2.3SupplyingandFixing.mmdiaclampsssAGIpipebracketupto2.7meterslongterminatedwithareducingcollarof40x25mmtowhichextrapipeof175mmlengthisfixedforfixingMV/SV/MH/FTLstreetlightfittingofallcapacitiesonrail/RCC/wall/tubularpole,usingsuitableclamps,bolts,nutsandwiringusingsuitablecapacitywires. Using 40mm dia G.I.PipeEach1478.01478.08.0FalseNoneNoneFalseNoneFalse11824.00
3524012126629None13.5Fixinghalogen/metalhalide/SVL/IL/LEDfloodlightfittingoverexistingpole/wallceilingincludingclamps,bolts,nutsandwiringusing suitable capacity wires.Each162.0162.08.0FalseNoneNoneFalseNoneFalse1296.00
3524013126629None11.14.3Supplyingandfixingofslimboxfitting,madeoutofCRCASheetmetalbodywithlockingtypeholdercompletelywired.ExcludingBallast & Fluorescent Tube. 2 x 4' Tube light fitting.Each421.0421.011.0FalseNoneNoneFalseNoneFalse4631.00
3524014126629None12.56Supplying,fixing,wiring,earthelectrodeforgroundingconduits,I.C.cutoutsandotherequipment'sonthemeterboardusing40mmdia2.90mmthickGIpipe2.5mlongburiedinapit.Thepitshouldbefilledwithequalproportionofsaltandcharcoal150mmall-roundthepipetocompletedepth.Theconnectionfromthepipetotheconduitetc.,istobeestablishedthroughGIwireofsizeasperlSIspecification7.3.3.ofIS732using12mmdiabolts,nuts,washersandchecknutsetc., the pipe shall have 16 through holes of 12 mm diaNo3510.03510.01.0FalseNoneNoneFalseNoneFalse3510.00
3524015126629None32.091.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 35 Sqmm, 3.5 Core, (14 GI Strips - 4 x 0.8 mm) 287059Km154062.0154062.00.03FalseNoneNoneFalseNoneFalse4621.860
3524016126629None33.04Compression type Aluminium Tubular in Line Connector for Aluminum Conductor 35 Sqmm 288608No4.04.08.0FalseNoneNoneFalseNoneFalse32.00
3524017126629None21.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 35 to 95 SqmmKm31139.031139.00.03FalseNoneNoneFalseNoneFalse934.170
3524018126629None29.03Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. In Hard SoilCum389.0389.015.0FalseNoneNoneFalseNoneFalse5835.00
3524019126629None13.14Fixingoneexhaustfaninthenitchalreadyleftinthewallwithboltsandnutsand5A.ceilingrosewithsufficientlengthof23/0.0076inch PVC insulated twin core wire.Each492.0492.04.0FalseNoneNoneFalseNoneFalse1968.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17210239560001NoneNoneELIGIBILITYTenders from Joint ventures are not acceptableNone
17210239560001NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of KarnatakaNone
17210239560002NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders The departments shall not be responsible for non accessibility of KPPP portal due to internet connectivity issues and technical glitches at bidders endNone
17210239560000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17210239560000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17210303390000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidderNone
17210303590000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender documentNone
17210303880000NoneNoneELIGIBILITYThe Tenderer shall obtain the work done certificate in the prescribed format from the competent Authority not below the rank of Executive Engineer (District Level Officer) and scan the original Certificates and attach file to the Bid. The Original Certificate/Certificates shall be produced at the time of opening of technical bids for physical verificationNone
17210303990000NoneNoneELIGIBILITYConditional tenders will not be acceptedNone
17210304260000NoneNoneELIGIBILITYFinancial Year will be reckoned as the period between first day of April and Thirty first day of March of succeeding year (both days inclusive)None
17210304540000NoneNoneELIGIBILITYThe Tenderer shall scan the Original Ownership Documents/Lease/Hire commitment Agreement for the Machinery and attach the scanned file to the Bid. The original Documents shall be produced at the time of opening technical Bids for physical verificationNone
17210304720000NoneNoneELIGIBILITYThe tenderer shall note that the scanned Documents can also be uploaded in the tasks created under Document/Evidence Required from the BidderNone
17210304870000NoneNoneELIGIBILITYThe Employer reserves the right to Reject any or all Tenders without assigning any reasonNone
17210304960000NoneNoneELIGIBILITYThe tenderer should maintain the road during the defective liability periodNone
17210305130000NoneNoneELIGIBILITYThe Department is not responsible for any delay in accessing KPPP portalNone
17210305400000NoneNoneELIGIBILITYTender shall note that the Tenders of those found Eligible as mentioned in Clause-3 - Qualification of the Tenderer in Section 2: Instructions to Tenders (ITT), will only be considered for evaluationNone
17210305800000NoneNoneELIGIBILITYTenderer shall note that unit rate to be quoted includes all the sundry expenses, all leads, all lifts and hire charges of machinery, taxes, royalty etcNone
17210306070000NoneNoneELIGIBILITYThe defect liability period for this work is 365 daysNone
17210306300000NoneNoneELIGIBILITYBidders are advised to note that, 18% GST will be added to the contract amountNone
17210306860000NoneNoneELIGIBILITYThe successful Tenderer must Deliver Security Deposit Amount equivalent to 5 Percentage of contract price in the form of DD TDR Bank Guarantee plus additional security for unbalanced tender as per GO No PWD 289 CRM 2013 Bangalore. Dated 13 1 .2013None
17210307070000NoneNoneELIGIBILITYThe successful bidder should submit the addl. security deposit in form of Original DD/FDR/BG to this office at the time of execution of the agreementNone
17210307320000NoneNoneELIGIBILITYThe successful bidder should submit the addl. security deposit in form of Original DD/FDR/BG to this office at the time of execution of the agreementNone
17210307570000NoneNoneELIGIBILITYPeriod for completion of this work is 9 (Nine) months including MonsoonNone
17210309110000NoneNoneELIGIBILITYThe Tenderer shall furnish as part of his tender earnest money deposit in the amount as shown in column 4 of the Table of IFT for this particular work. Tenderer can pay the full EMD amount of Rs.2,00,000.00 through e-payment or the Earnest Money Deposit shall be in two parts. Part 1 Rs1,00,000.00 by e-payment Part 2 Rs.1,00,000.00 EMD shall be in favour of Executive Engineer PWD Yadgir Division Yadgir and may be in the form of Bankers Cheque OR Demand Draft OR Pay order in favour of Executive Engineer PWD Yadgir Division Yadgir payable at Yadgir to the Executive Engineer PWD Yadgir Division Yadgir or Bank Guarantee in the prescribed format obtained form any Nationalized OR Scheduled BankNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrification works and should have executed similar electrical works totaling Rs.3.91 lakhs (not less than 50% of electrical works) in any one yearPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Electrical License
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totaling Rs.3.98 Lakhs (not less than 50% of water supply / sanitary engineering works) in any one yearPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Water Supply License
NoneNoneNoneNoneMaximum of Civil Engineering works executed in any one year during the last five years (updated to 2024-25 price level) taking into account the completed as well as works in progress. (Financial turnover of previous shall be given a weightage of 10% per year to bring them to the price level of the 2024-25)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Statement on the Letter Head of the tenderer
NoneNoneNoneNoneTo qualify for award of this contract, each Tenderer in its name should have in the last five years i.e., 2019-20, 2020-21, 2021-22,2022-23 and 2023-24 (a) achieved in at least two financial years a minimum financial turn over (in all cases of civil engineering construction works only) Rs.208.62 Lakhs and The Financial Turn Over Certificate Should bear the UDIN Number invariably & duly signed by registered chartered Accountant. The Certificate without UDIN number will not be consideredPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneTo qualify forwarded of this contract, each Tenderer in its name have should in the last five year i.e.2019-20 to 2023-24 (c) executed in any one year the following minimum quantities of work (As per Govt Circular No.PW 60 CRM 2021 Bengaluru Dtd.08.11.2021 (1)Earthwork/Sub-Grade/ Earth Filling: 275.27 Cum (2)PCC/RCC: 212.58 Cum (3)TMT Steel: 18.90 Tonne (4)UCRS/CRS/BBM: 141.92 Cum (5)MS Grill :526.2 Kgs (6)Plastering : 1676.56 Sqm, (7)Flooring: 508.2 SqmPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneAvailability by owning at least 50 percentage of the required specified key and critical equipment for this work and remaining 50 percentage can be deployed on lease/hire basis for all works provided, the relevant documents (commitment agreements etc.,) for availability for this work are furnished (As per Govt Circular No.PW 60 CRM 2021 Dtd.08.11.2021) 1)Excavator-1 No.(Own/ Lease/Hire), 2)Tippers- 2 Nos. (1 Nos. Own and 1 Nos Lease/Hire) 3)C.C Mixer- 1No. (Own/Lease/Hire) 4)Pin/Plate Vibrator: 2 Nos. Each (Own/Lease/Hire) 5)Water Tanker with Pumping Machinery- 2 Nos.(Own Lease/Hire)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned copies of Hire/ Lease agreement documents of Equipments/ Machineries Scanned copies of Ownership
NoneNoneNoneNoneAssessed Tender Capacity Shall be more than the Tendered AmountCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Assessment on the Letter Head of this Tenderer
NoneNoneNoneNoneTo qualify for award of this contract, each Tenderer in its name should have in the last five years i.e., 2019-20, 2020-21, 2021-22, 2022-23 and 2023-24 (b)Satisfactorily completed, as prime contractor, at least one similar work of value not less than Rs.52.16 LakhsFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneLiquid Assets and/or availability of credit facilities of not less than Rs.34.77 Lakhs (Credit Lines/Letter of Credit/Certificates from the Banks for meeting the fund requirement etcFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneLatest income tax clearance certificate along with last five years balance sheet and profit & loss statement duly certified by the CAFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneList of Financial Resources with CertificatesFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneQualification and experience of the key technical and Management personnel in permanent employment with the Tenderer and those that are proposed to be deployed on this work, if work is awardedFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Biodata of the Personnel
NoneNoneNoneNoneList of existing commitments Value at 2024-25 price level, of existing commitments and on-going works to be executed during the next 12 months (financial commitment of previous years shall be given a weight of 10% per year to bring them to the price level of 2024-25) (Month wise commitment shall be furnished)OthersExisting Commitments
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Statement on the Letter Head of the Tenderer
NoneNoneNoneNoneInformation of the works for which Tenderer has submitted TenderOthersSubmitted Tender
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Information in Format 7
NoneNoneNoneNoneBanker Details for referenceOthersBanker Details
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Banker Details
NoneNoneNoneNoneInformation Litigation in which the Tenderer is involvedOthersLitigation
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Information in Format 10
NoneNoneNoneNoneThe proposed methodology and programme of construction, backed with equipment planning and deployment, duly supported with broad calculations and quality control procedures proposed to be adopted, justifying their capability of execution and completion of work as per technical specifications within the stipulated period of completionOthersProgramme
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- CPM/ PERT CHART
NoneNoneNoneNoneInformation on works which are yet to be completedOthersYet to be completed
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Information in Format 5
NoneNoneNoneNoneConstitutional or Legal Status of the TendererOthersLegal status
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNonePart-2 Rs.1,00,000.00 EMD Shall be in favour of Executive Engineer, PWD Division. Yadgir and may be in the form of Bankers Cheque OR Demand Draft OR Pay Order in favour of Executive Engineer, PWD Division. Yadgir payable at yadgir to the Executive Engineer,PWD Divn. Yadgir of Bank Guarentee in the prescribed format obtained form any Nationalized OR Scheduled BanksThe tenderer should upload scanned Original Bank Guarentee of Part-2 EMD the qualified tenderer L1 must submit the original copy of the BG at the time of agreement. As GO PWD 107 CRM 2013 Dated 20.02.2013OthersEMD
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned copy of Bankers Cheque / Demand Draft/ Pay order/ pledged small savings Instruments/ BG
NoneNoneNoneNoneInformation of the works for which tender acceptance letters are receivedOthersTender Acceptance
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Information in Format 6 and Letter of Acceptance
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
To qualify for award of this contract, each Tenderer in its name should have in the last five years i.e 2019-20 to 2023-24 a- achieved in at least two financial years a minimum financial turn over in all cases of civil engineering construction works only Rs.208.62 Lakhs and The Financial Turn Over Certificate Should bear the UDIN Number invariably & duly registered charted Accountant. The Certificate without UDIN number will not be consideredTrueTechnical Bid
Contractor Registration Class-III & AboveTrueTechnical Bid
To qualify for award of this contract each Tenderer in its name should have in last five years i.e., 2019-20 to 2023-24 b- Satisfactorily completed as prime contractor, at least one similar work of value not less than Rs.52.16 LakhsTrueTechnical Bid
Liquid Assets and/or availability of credit facilities of not less than Rs.34.77 Lakhs Credit Lines/Letter of Credit/Certificates from the Banks for meeting the fund requirement etcTrueTechnical Bid
Latest income tax clearance certificate along with last five years balance sheet and profit & loss statement duly certified by the CATrueTechnical Bid
To qualify forwarded of this contract, each Tenderer in its name have should in the last five year i.e.2019-20 to 2023-24 c-executed in any one year the following minimum quantities of work. As per Govt Circular No.PW 60 CRM 2021 Bengaluru Dtd.08.11.2021 1-Earthwork/Sub-Grade/ Earth Filling-275.27 Cum 2- PCC/RCC-212.58 Cum 3-TMT Steel-18.90 Tonne 4-UCRS/CRS/BBM-141.92 Cum 5- MS Grill -526.20 Kgs 6-Plastering - 1676.56 Sqm, 7-Flooring- 508.2 SqmTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1721289836000
version0
createdDateNone
modifiedDateNone
blockNumberPWD DIVISION YADGIR
streetNone
cityYADGIR
stateKarnataka
pin585202
tenderRecallDTONone