tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1721023955000 | 0 | None | None | Buildings | Ground Floor | 9401441.5 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3523890 | 126626 | None | P:8, I.No 1.12. PWD SR 2023-24 Volume 1 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. | Cum | 99.75 | 99.75 | 12.6 | False | None | None | False | None | False | 1256.85 | 0 | 3523891 | 126626 | None | P:8, I.No 1.14 PWD SR 2023-24 Volume 1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 107.1 | 107.1 | 195.86 | False | None | None | False | None | False | 20976.606 | 0 | 3523892 | 126626 | None | P:8, I.No 1.14.2 PWD SR 2023-24 Volume 1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth 3 m to 6 m | Cum | 122.85 | 122.85 | 38.43 | False | None | None | False | None | False | 4721.1255 | 0 | 3523893 | 126626 | None | P:15, I.No 2.1.4 PWD SR 2023-24 Volume 1 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6527.85 | 6527.85 | 68.93 | False | None | None | False | None | False | 449964.7005 | 0 | 3523894 | 126626 | None | P:15, I.No 2.2.1 PWD SR 2023-24 Volume 1 | Providing and laying in position Cement Concrete for all Foundation works.
The granite/trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,
labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6601.35 | 6601.35 | 49.27 | False | None | None | False | None | False | 325248.5145 | 0 | 3523895 | 126626 | None | Vol-I S R Sl no. 1 (a) Page No. 111 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding for Foundation upto Plinth Isolated add 8% | Cum | 528.11 | 528.11 | 49.27 | False | None | None | False | None | False | 26019.9797 | 0 | 3523896 | 126626 | None | P:16, I.No 2.5.2 PWD SR 2023-24 Volume 1 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7185.15 | 7185.15 | 32.85 | False | None | None | False | None | False | 236032.1775 | 0 | 3523897 | 126626 | None | Vol-I S R Sl No. 9 Page No 111 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding for RCC Columns / Shaft (Slip Centering) add 70% | Cum | 5029.6 | 5029.6 | 32.85 | False | None | None | False | None | False | 165222.36 | 0 | 3523898 | 126626 | None | P:16, I.No 2.5.2 PWD SR 2023-24 Volume 1 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7185.15 | 7185.15 | 16.79 | False | None | None | False | None | False | 120638.6685 | 0 | 3523899 | 126626 | None | Vol-I S R Sl no. 2 Page No. 111 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding for Plinth Beams of Buildings add 50% | Cum | 3592.57 | 3592.57 | 16.79 | False | None | None | False | None | False | 60319.2503 | 0 | 3523900 | 126626 | None | P:16, I.No 2.5.2 PWD SR 2023-24 Volume 1 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7185.15 | 7185.15 | 32.28 | False | None | None | False | None | False | 231936.642 | 0 | 3523901 | 126626 | None | Vol-I S R Sl no. 14 Page No. 112 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts add 60% | Cum | 4311.09 | 4311.09 | 32.28 | False | None | None | False | None | False | 139161.9852 | 0 | 3523902 | 126626 | None | P:16, I.No 2.5.2 PWD SR 2023-24 Volume 1 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7185.15 | 7185.15 | 64.93 | False | None | None | False | None | False | 466531.7895 | 0 | 3523903 | 126626 | None | Vol-I S R Sl no. 15 Page No. 112 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding for RCC Roof Slabs add 50% | Cum | 3592.57 | 3592.57 | 64.93 | False | None | None | False | None | False | 233265.5701 | 0 | 3523904 | 126626 | None | P:16, I.No 2.5.2 PWD SR 2023-24 Volume 1 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7185.15 | 7185.15 | 0.68 | False | None | None | False | None | False | 4885.902 | 0 | 3523905 | 126626 | None | Vol-I S R Sl no. 19 Page no. 112 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding for Chejjas, Canopy & Other Architectural projections of
minor sections add 45% | Cum | 3233.32 | 3233.32 | 0.68 | False | None | None | False | None | False | 2198.6576 | 0 | 3523906 | 126626 | None | Vol-I I No. 2.11 (a) Page No. 18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and
technical specification Buildings | t | 93929.85 | 93929.85 | 23.61 | False | None | None | False | None | False | 2217683.7585 | 0 | 3523907 | 126626 | None | Vol-II I No 5.3 Page No 9 | Providing Coursed rubble masonry (second sort) with hard stone in
foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6515.25 | 6515.25 | 38.65 | False | None | None | False | None | False | 251814.4125 | 0 | 3523908 | 126626 | None | Vol-II I No. 5.4 Page No. 9 | Providing Size Stone masonry with hard stone in foundation & plinth with
Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 15.81 | False | None | None | False | None | False | 106060.5945 | 0 | 3523909 | 126626 | None | Vol-I I No. 1.11 Page no. 7 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations
and other similar works etc. in layers not exceeding 20cm in depth, consolidating
each deposited layer by ramming and watering, lead up to 50 m and lift upto
1.5 m. | Cum | 454.65 | 454.65 | 448.41 | False | None | None | False | None | False | 203869.6065 | 0 | 3523910 | 126626 | None | Vol-II INo 6.8 Page No. 14 | Providing Brick work with common burnt clay Non Modular bricks of
class designation 3.5 in superstructure above plinth level in all shapes and
sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of
all materials, labour, scaffolding and usage charges of machinery & other
incidental charges complete as per the direction of engineer incharge of
work. | Cum | 8367.45 | 8367.45 | 122.95 | False | None | None | False | None | False | 1028777.9775 | 0 | 3523911 | 126626 | None | Vol-II I No. 6.15 Page No. 14 | Providing Half brick masonry with common burnt clay Non Modular
bricks of class designation 3.5 in superstructure above plinth level up
to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including
cost of all materials, labour, scaffolding and usage charges of machinery
& other incidental charges complete as per the direction of engineer
incharge of work | Sqm | 1084.65 | 1084.65 | 129.98 | False | None | None | False | None | False | 140982.807 | 0 | 3523912 | 126626 | None | Vol-II I No. 12.13.1 Page No. 100 | Providing Salwood frames of doors, windows, clerestory windows,
ventilators and other frames, wrought, framed or assembled including
making plaster groves (excluding cost of cement concrete and side clamps),
but including cost of materials, labour, usage charges complete as per
specifications. | Cum | 103755.75 | 103755.75 | 0.87 | False | None | None | False | None | False | 90267.5025 | 0 | 3523913 | 126626 | None | Vol-II I No. 12.15 Page No. 100 | Providing and fixing in position fully panelled Honne wood shutters for
doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm
wide top rail and stiles 100mm wide as per drawing and panels of 25mm
thick including cost of materials, labour, usage charges complete as per
specifications. ( excluding cost of fixtures ) | Sqm | 7816.2 | 7816.2 | 30.72 | False | None | None | False | None | False | 240113.664 | 0 | 3523914 | 126626 | None | Vol-II I No. 12.55.1 Page No. 104 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled
Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and
15x15mm for top & bottom rails, covered with heat moulded Prelaminated
PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm
thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom
rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert
for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated
on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC
Designer beading on either side & joined together with solvent cement
adhesive etc., Complete as per manufacturers specification & direction of
Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. with both side prelam | Sqm | 2484.3 | 2484.3 | 10.8 | False | None | None | False | None | False | 26830.44 | 0 | 3523915 | 126626 | None | Vol-II I No. 11.34B Page No. 86 | Providing and fixing M.S. grills of required pattern in frames of windows
etc. with M.S. flats, square or round bars etc. including priming coat with
approved steel primer all complete. Fixed to openings /wooden frames
with rawl plugs screws etc. | Kg | 192.15 | 192.15 | 657.72 | False | None | None | False | None | False | 126380.898 | 0 | 3523916 | 126626 | None | Vol-II I No. 11.35.1.1 Page No. 87 | Providing and fixing aluminium work for doors, windows, ventilators
and partitions with extruded built up standard tubular sections/
appropriate sections and other sections of approved make conforming to
IS: 733 and IS:1285, fixing with dash fasteners of required dia and
size, including necessary filling up the gaps at junctions, i.e. at top,
bottom and sides with required EPDM rubber/ neoprene gasket etc.
Aluminium sections shall be smooth, rust free, straight, mitred and jointed
mechanically wherever required including cleat angle, Aluminium snap
beading for glazing / paneling, C.P. brass / stainless steel screws, all
complete as per architectural drawings and the directions of Engineer-incharge.
(Glazing, paneling and dash fasteners to be paid for separately)
:For Fixed Portion : Anodised aluminium (anodised transparent or dyed
to required shade according to IS: 1868, Minimum anodic coating of grade
AC 15) including cost of materials, labour, usage charges of machinery
complete as per specifications. | Kg | 474.6 | 474.6 | 259.2 | False | None | None | False | None | False | 123016.32 | 0 | 3523917 | 126626 | None | Vol-II I no. 11.30.1 Page No. 85 | Providing & fixing glass panes with putty and glazing clips in steel
doors, windows, clerestory windows, all complete with : 4.0 mm thick
glass panes including cost of materials, labour, usage charges of machinery
complete as per specifications and as per directions of the Engineer-in-
Charge. | Sqm | 957.6 | 957.6 | 9.72 | False | None | None | False | None | False | 9307.872 | 0 | 3523918 | 126626 | None | Vol-II I No. 11.28 Page No. 85 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow
tubes, channels, plates etc., including welding, grinding, buffing, polishing
and making curvature (wherever required) and fitting the same with
necessary stainless steel nuts and bolts complete, i/c fixing the railing
with necessary accessories & stainless steel dash fasteners, stainless
steel bolts etc., of required size, on the top of the floor or the side of waist
slab with suitable arrangement as per approval of Engineer-in- charge,
(for payment purpose only weight of stainless steel members shall be
considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
including cost of materials, labour, usage charges of machinery complete
as per specifications and as per directions of the Engineer-in-Charge. | Kg | 593.25 | 593.25 | 89.0 | False | None | None | False | None | False | 52799.25 | 0 | 3523919 | 126626 | None | Vol-II I No. 8.1.1 Page No. 41 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:
4 fine sand) to brick masonry including rounding off corners wherever
required smooth rendering, providing and removing scaffolding, including
cost of materials, labour, curing complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 267.75 | 267.75 | 519.29 | False | None | None | False | None | False | 139039.8975 | 0 | 3523920 | 126626 | None | Vol-II I No. 8.2.1 Page No. 41 | Providing 15 mm cement plaster on the rough side of single or half brick
wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners
wherever required smooth rendering, providing and removing scaffolding,
including cost of materials, labour, curing complete as per specifications
and as per directions of Engineer-in-charge. | Sqm | 309.75 | 309.75 | 980.33 | False | None | None | False | None | False | 303657.2175 | 0 | 3523921 | 126626 | None | Vol-II I No. 8.3.1 Page No. 41 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to
brick/stone masonry including rounding off corners wherever required
smooth rendering, providing and removing scaffolding, including cost of
materials, labour, curing complete as per specifications and as per directions
of Engineer-in-charge. | Sqm | 371.7 | 371.7 | 596.08 | False | None | None | False | None | False | 221562.936 | 0 | 3523922 | 126626 | None | Vol-II I No. 8.19.2 Page No. 44 | Providing Raised and cut pointing: Pointing on stone work with cement
mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely
lining, including cost of materials, labour, curing as per specifications and
as per directions of Engineer-in-charge. | Sqm | 486.15 | 486.15 | 54.38 | False | None | None | False | None | False | 26436.837 | 0 | 3523923 | 126626 | None | Vol-II I No. 9.17.5 Page No. 61 | Providing and laying Vitrified tiles with thickness 9-10 mm in different
sizes with water absorption less than 0.08 % and conforming to I.S. 15622,
of approved make, in all colours & shade, over 12 mm thick bed of cement
mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry
@ 3.3 kg/ m2 including grouting the joint with white cement & matching
pigments etc. complete.Size of Tile 600x1200 mm | Sqm | 1411.2 | 1411.2 | 465.32 | False | None | None | False | None | False | 656659.584 | 0 | 3523924 | 126626 | None | Vol-II I No. 9.30 Page No. 64 | Providing and laying flooring and steps fine machine polished granite stone
slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished
with cement mortar 1:3 over existing cement concrete bed , including
cost of materials, mortar, labour, curing complete as per specifications | Sqm | 5594.4 | 5594.4 | 30.75 | False | None | None | False | None | False | 172027.8 | 0 | 3523925 | 126626 | None | Vol-II I No. 9.11 Page No. 60 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness
to be specified by the manufacturer), of 1st quality conforming to
IS : 15622, of approved make, in all colours, shades, except White, Ivory,
Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1
Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2
including pointing the joints with white cement and matching pigments
etc., complete. | Sqm | 933.45 | 933.45 | 21.68 | False | None | None | False | None | False | 20237.196 | 0 | 3523926 | 126626 | None | Vol-II I No. 9.39 Page No. 65 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm
thick on 10mm thick cement plaster 1:3 and jointed with white cement
slurry over existing rough plaster surface using glazed tiles of approved
make and size including cost of materials, labour, complete as per
specifications. | Sqm | 1521.45 | 1521.45 | 117.51 | False | None | None | False | None | False | 178785.5895 | 0 | 3523927 | 126626 | None | Vol-II I No. 8.51 Page No. 50 | Providing and applying white cement based putty of average thickness
1 mm, of approved brand and manufacturer, over the plastered
wall surface to prepare the surface even and smooth complete as per
specifications and as per directions of Engineer in charge. | Sqm | 105.0 | 105.0 | 1382.11 | False | None | None | False | None | False | 145121.55 | 0 | 3523928 | 126626 | None | Vol-II I No. 8.27 Page No. 45 | Applying one coat of water thinnable cement primer of approved brand
and manufacture on wall surface :Water thinnable cement primer to give
an even shade after thoroughly brooming the surface to remove all dirt,
dust, mortar drops and foreign matter including preparing the surface
even and sand paper smooth, cost of materials, labour complete as per
specifications and as per directions of Engineer-in-charge. | Sqm | 55.65 | 55.65 | 1382.11 | False | None | None | False | None | False | 76914.4215 | 0 | 3523929 | 126626 | None | Vol-II I No. 8.39 Page No. 48 | Wall painting with acrylic emulsion paint of approved brand and
manufacture to give an even shade :Two coats on new work after
thoroughly brooming the surface to remove all dirt, dust, mortar drops
and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 133.35 | 133.35 | 1382.11 | False | None | None | False | None | False | 184304.3685 | 0 | 3523930 | 126626 | None | Vol-II I No. 8.30 Page No. 46 | Finishing walls with Acrylic Smooth exterior paint of required shade :New
work (Two coat applied @ 1.67L/10 m² over and including priming coat of
exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality
to give an even shade, after thoroughly brooming the surface to remove all
dirt, dust, mortar drops and foreign matter including preparing the surface
even and sand paper smooth, cost of materials, labour complete as per
specifications and as per directions of Engineer-in-charge. | Sqm | 182.7 | 182.7 | 650.46 | False | None | None | False | None | False | 118839.042 | 0 | 3523931 | 126626 | None | Vol-II I No. 8.33.2 Page No. 46 | Painting wood work with Deluxe Multi Surface Paint of required shade.
Two coat applied @ 0.90L/10 m² over an under coat of primer applied
@0.75 L/10 m² of approved brand and manufacture to give an even shade
including preparing the surface after thorougly cleaning oil, grease, dirt
and foreign matter, sand papering and knotting , cost of materials, labour
complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 144.9 | 144.9 | 70.66 | False | None | None | False | None | False | 10238.634 | 0 | 3523932 | 126626 | None | Vol-II I No. 8.33.3 Page No. 47 | Painting Steel work with Deluxe Multi Surface Paint to give an even
shade. Two coat applied @ 0.90L/10 m² over an under coat of primer
applied @ 0.80 L/10 m² of approved brand and manufacture including
preparing the surface after thorougly cleaning oil, grease, dirt and foreign
matter, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 145.95 | 145.95 | 59.4 | False | None | None | False | None | False | 8669.43 | 0 | 3523933 | 126626 | None | Vol-II I No. 11.5.2 Page No. 77 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6
mm angle iron and 3 mm M.S. gusset plates at the junctions and
corners, all necessary fittings complete, including applying a priming
coat of approved steel primer. Using flats 30x6mm for diagonal braces
and central cross piece including cost of materials, labour, usage charges
of machinery complete as per specifications and as per directions of the
Engineer-in-Charge. | Sqm | 4454.1 | 4454.1 | 1.89 | False | None | None | False | None | False | 8418.249 | 0 | 3523934 | 126626 | None | Vol-II I No. 11.16.1 Page No. 82 | Providing and fixing Steel work in built up tubular (round, square or
rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,
fixing in position and applying a priming coat of approved steel primer,
including welding and bolted with special shaped washers etc. complete.
Hot finished welded type tubes including cost of materials, labour, usage
charges of machinery complete as per specifications and as per directions
of the Engineer-in-Charge. | Kg | 142.8 | 142.8 | 57.76 | False | None | None | False | None | False | 8248.128 | 0 | 3523935 | 126626 | None | Vol-II I No. 7.1.1 Page No. 20 | Providing & fixing corrugated G.S. sheet roofing including vertical /
curved surface fixed with polymer coated J or L hooks, bolts and nuts 8
mm diameter with bitumen and G.I. limpet washers or with G.I. limpet
washers filled with white lead, including a coat of approved steel primer
and two coats of approved paint on overlapping of sheets complete as
per design drawings (up to any pitch in horizontal/ vertical or curved
surfaces), excluding the cost of purlins, rafters and trusses and including
cutting to size and shape wherever required as per the direction of
Engineer in charge 0.63 mm thick with zinc coating not less than 275 g/ m² | Sqm | 922.95 | 922.95 | 17.33 | False | None | None | False | None | False | 15994.7235 | 0 |
| 1721023955000 | 0 | None | None | Buildings | Water Supply and Sanitation | 397599.72 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3523936 | 126627 | None | P:131, I.No 14.2.2 PWD SR 2023-24 Volume 2 | Providing and fixing white vitreous china pedestal type water closet
(European type W.C. pan) with seat and lid, 10 litre low level white P.V.C.flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked black solid plastic seat and lid | Each | 5076.75 | 5076.75 | 2.0 | False | None | None | False | None | False | 10153.5 | 0 | 3523937 | 126627 | None | P:131, I.No 14.1.1 PWD SR 2023-24 Volume 2 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests | Each | 5128.2 | 5128.2 | 4.0 | False | None | None | False | None | False | 20512.8 | 0 | 3523938 | 126627 | None | P:132, I.No 14.7.1 PWD SR 2023-24 Volume 2 | Providing and fixing wash basin with C.I. brackets, 15 mm PTMT pillar cock, 32 mm PTMT waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps | Each | 3236.1 | 3236.1 | 10.0 | False | None | None | False | None | False | 32361.0 | 0 | 3523939 | 126627 | None | P:110, I.No 13.8.2.2 PWD SR 2023-24 Volume 2 | Providing and fixing unplasticised PVC connection pipe with brass unions : 45 cm length 20 mm nominal bore | Each | 115.5 | 115.5 | 10.0 | False | None | None | False | None | False | 1155.0 | 0 | 3523940 | 126627 | None | P:137, I.No 14.37.1 PWD SR 2023-24 Volume 2 | Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms | Each | 321.3 | 321.3 | 10.0 | False | None | None | False | None | False | 3213.0 | 0 | 3523941 | 126627 | None | P:117, I.No 13.2.2 PWD SR 2023-24 Volume 2 | Providing and fixing brass bib cock of approved quality : 20 mm nominal bore | Each | 320.25 | 320.25 | 16.0 | False | None | None | False | None | False | 5124.0 | 0 | 3523942 | 126627 | None | P:120, I.No 13.20.2 PWD SR 2023-24 Volume 2 | Providing and fixing PTMT pillar cock of approved quality and colour.15 mm nominal bore, 125 mm long foam flow, weighing not less than 120 gms | Each | 329.7 | 329.7 | 10.0 | False | None | None | False | None | False | 3297.0 | 0 | 3523943 | 126627 | None | P:117, I.No 13.5.2 PWD SR 2023-24 Volume 2 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore | Each | 329.7 | 329.7 | 1.0 | False | None | None | False | None | False | 329.7 | 0 | 3523944 | 126627 | None | P:117, I.No 13.5.3 PWD SR 2023-24 Volume 2 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore | Each | 348.6 | 348.6 | 1.0 | False | None | None | False | None | False | 348.6 | 0 | 3523945 | 126627 | None | P:115, I.No 13.4.2 PWD SR 2023-24 Volume 2 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore | No | 627.9 | 627.9 | 1.0 | False | None | None | False | None | False | 627.9 | 0 | 3523946 | 126627 | None | P: 123, I.No 13.34 PWD SR 2023-24 Volume 2 | Providing and placing on terrace (at all floor levels) polyethylene
water storage tank, IS : 12701 marked, with cover and suitable locking
arrangement and making necessary holes for inlet, outlet and overflow
pipes but without fittings and the base support for tank | Ltr | 9.45 | 9.45 | 2000.0 | False | None | None | False | None | False | 18900.0 | 0 | 3523947 | 126627 | None | P: 122, I.No 13.32.3 PWD SR 2023-24 Volume 2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00
m spacing. This includes jointing of pipes & fittings with one step CPVC
solvent cement and the cost of cutting chases and making good the
same including testing of joints complete as per direction of Engineer in
Charge. Concealed work, including cutting chases and making good the
walls etc. 25 mm nominal dia pipes | m | 500.85 | 500.85 | 150.0 | False | None | None | False | None | False | 75127.5 | 0 | 3523948 | 126627 | None | P: 122, I.No 13.33.4 PWD SR 2023-24 Volume 2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings
with one step CPVC solvent cement, trenching, refilling & testing of joints
complete as per direction of Engineer in Charge. External work 32 mm nominal dia Pipes | m | 390.6 | 390.6 | 100.0 | False | None | None | False | None | False | 39060.0 | 0 | 3523949 | 126627 | None | P:113, I.No 10.1.8 PWD SR 2023-24 Volume V | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest
amendments and conveying to worksite, rolling and lowering into
trenches, laying true to line and level and perfect linking at joints, testing
and commissioning, including loading unloading at both destinations
and cuts of pipes wherever necessary including jointing of PVC pipes
and specials (excluding cost of specials) with jointing of approved
type, with all labour with all lead & lift including encasing the pipe
alround to a depth of not less than 15 cms. with soft gravel or selected
earth available from the excavation etc. complete and giving necessary
hydraulic test to the required pressure as per ISS (Contractor will make
his own arrangements for procuring water for testing) etc. complete For: PVC pipes 140mm dia., 6 kg/sqcm & class 3 | m | 613.2 | 613.2 | 80.0 | False | None | None | False | None | False | 49056.0 | 0 | 3523950 | 126627 | None | P:113, I.No 10.1.7 PWD SR 2023-24 Volume V | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest
amendments and conveying to worksite, rolling and lowering into
trenches, laying true to line and level and perfect linking at joints, testing
and commissioning, including loading unloading at both destinations
and cuts of pipes wherever necessary including jointing of PVC pipes
and specials (excluding cost of specials) with jointing of approved
type, with all labour with all lead & lift including encasing the pipe
alround to a depth of not less than 15 cms. with soft gravel or selected
earth available from the excavation etc. complete and giving necessary
hydraulic test to the required pressure as per ISS (Contractor will make
his own arrangements for procuring water for testing) etc. complete For: PVC pipes 110mm dia., 6 kg/sqcm & class 3 | m | 431.55 | 431.55 | 100.0 | False | None | None | False | None | False | 43155.0 | 0 | 3523951 | 126627 | None | P:113, I.No 10.1.5 PWD SR 2023-24 Volume V | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest
amendments and conveying to worksite, rolling and lowering into
trenches, laying true to line and level and perfect linking at joints, testing
and commissioning, including loading unloading at both destinations
and cuts of pipes wherever necessary including jointing of PVC pipes
and specials (excluding cost of specials) with jointing of approved
type, with all labour with all lead & lift including encasing the pipe
alround to a depth of not less than 15 cms. with soft gravel or selected
earth available from the excavation etc. complete and giving necessary
hydraulic test to the required pressure as per ISS (Contractor will make
his own arrangements for procuring water for testing) etc. complete For: PVC pipes 75mm dia., 6 kg/sqcm & class 3 | m | 231.0 | 231.0 | 77.0 | False | None | None | False | None | False | 17787.0 | 0 | 3523952 | 126627 | None | P:8, I.No 1.14.1 PWD SR 2023-24 Volume 1 | Earth work excavation for Foundation by mechanical means for all works &
depth upto 3 m, as per drawing and technical specifications, including setting
out, shoring, strutting, barricading, caution lights, including dressing of
excavated surfaces, disposing off or levelling the excavated earth or sorting
& stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5
m including cost of labour, tools, usage of machinery & other appurtenaces
required to complete the work In all kinds of soils Depth upto 3 m | Cum | 107.1 | 107.1 | 97.2 | False | None | None | False | None | False | 10410.12 | 0 | 3523953 | 126627 | None | P:7, I.No 1.10 PWD SR 2023-24 Volume 1 | Refilling available earth around trenches/pipelines, cables in layers not
exceeding 20 cms in depth, compacting each deposited layer by ramming after
watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour
complete as per specifications | Cum | 168.0 | 168.0 | 81.0 | False | None | None | False | None | False | 13608.0 | 0 | 3523954 | 126627 | None | P:191, I.No 16.10 PWD SR 2023-24 Volume V | Constructing brick masonry chamber of internal dimension 450x450mm
and depth of 600mm (inner dimensions) with modular bricks of CD 75
in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering
12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing
CI cover & frame etc. excluding the cost of CI frame and cover | Each | 4447.8 | 4447.8 | 12.0 | False | None | None | False | None | False | 53373.6 | 0 |
| 1721023955000 | 0 | None | None | Buildings | Sinking of Borewell | 241146.15 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3523955 | 126628 | None | V-5, Pg. No.140, Item.No:12.4 | Geophysical investigation at site for sinking borewells for Providing
drinking water to the habitation either through the Hand Pump MWS
or P.W.S.S, by vertical electrical sounding by adopting Venner or
Schlumbergers's method, including reconnaissance survey of geological
formation. Geophysical investigation of existing ground water in the
vicinity, its quality, quantity and acceptability of the users, indicating
the location of the site, recommended depth of casing pipe required to
seal the top unconsolidated formation including an extra depth of 1.0
metre in consolidated formation for proper seating of casing pipe, depth
of drilling required to cover full depth of aquifer proposed to be tapped,
probable yield and other information required including transportation
of instruments and accessories to work site, engaging technical personal
and labour required etc. NOTE: 1) Additional rate on item 1&2 is
allowed for drilling in over burden and fixing Casing pipes beyond 20
M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%,
b) Above 30 M - 30% (Measurement of overburden is restricted to the
depth of casing pipe fixed excluding initial depth of 20M and projection
above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry
Borewell towards yield test. etc. complete | Each | 5552.4 | 5552.4 | 1.0 | False | None | None | False | None | False | 5552.4 | 0 | 3523956 | 126628 | None | Vol-V I No. 12.1.1 Page No. 139 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every
50m depth) Borewell depth of 0 to 50 Mtrs | m | 388.5 | 388.5 | 50.0 | False | None | None | False | None | False | 19425.0 | 0 | 3523957 | 126628 | None | Vol-V I No. 12.1.2 Page No. 139 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every
50m depth) Borewell depth of 50 to 100 Mtrs | m | 487.2 | 487.2 | 50.0 | False | None | None | False | None | False | 24360.0 | 0 | 3523958 | 126628 | None | Vol-V I No. 12.32 Page No. 143 | Supply of ISI mark 175mm nominal bore,plain and steel casing pipe
grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and
latest ammendments, electrical resistance welded steel tubes, material
and conforming to IS 1387-1993 and manufactured by basic open
hearth electric or basic oxygen process in random length of 5-7m both
ends.threaded conforming to IS 554-1985 one end fixed with socket
conforming to IS 4270-2001 and the other end with screwed pipes all
shall be responsibaly free from defects. The tubes shall be responsible
straight end should be with ISI marking weighing 25.10kg/m.prices
include Collar-Medium duty. | m | 2029.65 | 2029.65 | 12.0 | False | None | None | False | None | False | 24355.8 | 0 | 3523959 | 126628 | None | Vol-V I No. 10.1.9 Page No. 113 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest
amendments and conveying to worksite, rolling and lowering into
trenches, laying true to line and level and perfect linking at joints, testing
and commissioning, including loading unloading at both destinations
and cuts of pipes wherever necessary including jointing of PVC pipes
and specials (excluding cost of specials) with jointing of approved
type, with all labour with all lead & lift including encasing the pipe
alround to a depth of not less than 15 cms. with soft gravel or selected
earth available from the excavation etc. complete and giving necessary
hydraulic test to the required pressure as per ISS (Contractor will make
his own arrangements for procuring water for testing) etc. complete For: PVC pipes 160mm dia., 6 kg/sqcm & class 3 | m | 648.9 | 648.9 | 102.0 | False | None | None | False | None | False | 66187.8 | 0 | 3523960 | 126628 | None | Vol-V I No. 9.1.4 Page No. 95 | Providing, laying and jointing HDPE pipes of specified grade and
conforming to IS 4984-2016 with latest ammendments and conveying
to work site including loading and unloading at both destinations and
rolling and lowering into trenches, laying true to line and jointing of
pipes and specials with electrofusion welding, giving hydraulic test
as per relevant ISS with all lead and lifts including encasing the pipe
alround to a depth of not less than 15 cms. with soft gravel or selected
earth available from the excation, testing and commissioning. The
rate is exclusive of required specials and fittings wherever necessary
like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete
(Contractor will make his own arrangements for procuring water for
testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used.
For :HDPE PE 80 PN 6.0 HDPE Grade PE80-PN6.0,110mm dia | m | 492.45 | 492.45 | 95.0 | False | None | None | False | None | False | 46782.75 | 0 | 3523961 | 126628 | None | Vol-V I No. 13.11.5 Page No. 151 | Providing Submersible Pump Set of 150mm dia suitable for bore well and
confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt
Motor as per specifications, to work site as per necessary ammendments
and instructions of engineer incharge of work. For 3 HP etc. complete 3.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00" | Each | 29518.65 | 29518.65 | 1.0 | False | None | None | False | None | False | 29518.65 | 0 | 3523962 | 126628 | None | Vol-V I No. 13.22.2 Page No. 154 | Supply and delivery at site Brand new best make PVC insulated cable of
Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990
with ISI Mark and as per its latest amendments. 1x3x2.5 Sqm | m | 89.25 | 89.25 | 105.0 | False | None | None | False | None | False | 9371.25 | 0 | 3523963 | 126628 | None | Vol-V I No. 13.23.2 Page No. 155 | Supply, installing,testing and commissioning COMMON control panel
consisting of the following INCOMING:1 No set of Phase indicating
lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog
Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING
for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable
for respective HP 1 No. Electrcal Protection Like single Phase preventor,
under voltage over Volage, under current over current & dry run
protection suitable for the pump described above 1 no Indoor type NOTE:
1) DOL- Direct Online Starter
2) S-D- Star Delta Starter etc. complete. 3 to 6 HP pumps | Each | 10027.5 | 10027.5 | 1.0 | False | None | None | False | None | False | 10027.5 | 0 | 3523964 | 126628 | None | Vol-V I No. 13.39 Page No. 157 | Earthing: Providing and fixing and wiring earth electrode for grounding
circuits IC cutouts and other equipments on the meter board in the pit.
The pits should be filled up with equal proportion of salt and charcoal
150mm around the pipe to complete depth. The connection from the
pipe to the conduits etc. is to established through GI wire of sizes as per
clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts,
the pipe shall have 16 through holes of 12mm dia. | Job | 3937.5 | 3937.5 | 1.0 | False | None | None | False | None | False | 3937.5 | 0 | 3523965 | 126628 | None | Vol-V I No. 13.25.2 Page No. 154 | Supply and delivery at site of brand new best make non-return valve as
per IS 778/1984 with ISI Mark and as per its latest amendments Size 65 mm | Each | 1627.5 | 1627.5 | 1.0 | False | None | None | False | None | False | 1627.5 | 0 |
| 1721023955000 | 0 | None | None | Buildings | Electrical work | 390818.53 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3523966 | 126629 | None | Vol-VI I No. 1.2.1 Page No. 2 of 105 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe 19/20mm dia 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary | m | 66.0 | 66.0 | 110.0 | False | None | None | False | None | False | 7260.0 | 0 | 3523967 | 126629 | None | Vol-6 I No. 1.2.2 Page No. 2 of 102 | SupplyingheavygaugePVCconduitpipe.mmdia.mmthickconfirmingtoIS2509withsuitablesizebends,metal/PVCJunctionboxes,adhesivepasteetc.,andrunningbeforeconcretingtheslab.TheconduitshouldbetiedtothereinforcementrodsbyusingbindingwiresandunusedwaysofjunctionboxesandpipeendsshouldbecoveredusingPVCendenclosures,runwith18SWGGIfishwirewherever necessary 25 mm dia 2 mm thick | m | 78.0 | 78.0 | 35.0 | False | None | None | False | None | False | 2730.0 | 0 | 3523968 | 126629 | None | Vol-6 I No 1.7.1 Page No. 3 | Extra for Groove cutting in brick wall / CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing up to wall surface complete. up to 50 mm conduit in brick wall | m | 29.0 | 29.0 | 80.0 | False | None | None | False | None | False | 2320.0 | 0 | 3523969 | 126629 | None | 2.1.1 | SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingusing2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLSmultistrandPVCinsulatedcopperwire(confirmingtoIS-694:andlatestamendments)with a6AmpsflushtypeSPcontrolswitchshallbefixedontheexistingplasticsheet/gangbox,theotherendofthewiresshallbeterminatedwithsufficientlooselengthinawood/PVCroundblock.completeforeach outlet. Short point upto 3Mtr from tapping point to out let via switch | Point | 285.0 | 285.0 | 24.0 | False | None | None | False | None | False | 6840.0 | 0 | 3523970 | 126629 | None | 2.1.2 | SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingusing2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLSmultistrandPVCinsulatedcopperwire(confirmingtoIS-694:andlatestamendments)with a6AmpsflushtypeSPcontrolswitchshallbefixedontheexistingplasticsheet/gangbox,theotherendofthewiresshallbeterminatedwithsufficientlooselengthinawood/PVCroundblock.completeforeach outlet. Mediumpointabove3Mtrupto6Mtrfromtappingpointtooutletviaswitch | Point | 394.0 | 394.0 | 22.0 | False | None | None | False | None | False | 8668.0 | 0 | 3523971 | 126629 | None | 2.1.3 | SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingusing2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLSmultistrandPVCinsulatedcopperwire(confirmingtoIS-694:andlatestamendments)with a6AmpsflushtypeSPcontrolswitchshallbefixedontheexistingplasticsheet/gangbox,theotherendofthewiresshallbeterminatedwithsufficientlooselengthinawood/PVCroundblock.completeforeach outlet. Longpointabove6Mtrupto10Mtrfromtappingpointtooutletviaswitch | Point | 570.0 | 570.0 | 19.0 | False | None | None | False | None | False | 10830.0 | 0 | 3523972 | 126629 | None | 2.3.1 | Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 1 mm2 | m | 19.0 | 19.0 | 195.0 | False | None | None | False | None | False | 3705.0 | 0 | 3523973 | 126629 | None | 2.3.2 | Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 1.5 mm2 | m | 26.0 | 26.0 | 650.0 | False | None | None | False | None | False | 16900.0 | 0 | 3523974 | 126629 | None | 2.3.3 | Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 2.5 mm2 | m | 42.0 | 42.0 | 255.0 | False | None | None | False | None | False | 10710.0 | 0 | 3523975 | 126629 | None | 2.3.4 | Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 4 mm2 | m | 63.0 | 63.0 | 170.0 | False | None | None | False | None | False | 10710.0 | 0 | 3523976 | 126629 | None | 3.4.3 | Supplyingandflushmountingpowdercoated/galvanizedmetalboxsuitableformountingmodularswitchplates.Theboxshouldbefirmlyflush mounted after due groove cutting in Brick/Stone/C.C wall 4-5 Way | Each | 177.0 | 177.0 | 2.0 | False | None | None | False | None | False | 354.0 | 0 | 3523977 | 126629 | None | 3.4.4 | Supplyingandflushmountingpowdercoated/galvanizedmetalboxsuitableformountingmodularswitchplates.Theboxshouldbefirmlyflush mounted after due groove cutting in Brick/Stone/C.C wall 6 Way | Each | 220.0 | 220.0 | 2.0 | False | None | None | False | None | False | 440.0 | 0 | 3523978 | 126629 | None | 3.4.5 | Supplyingandflushmountingpowdercoated/galvanizedmetalboxsuitableformountingmodularswitchplates.Theboxshouldbefirmlyflush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way | Each | 261.0 | 261.0 | 10.0 | False | None | None | False | None | False | 2610.0 | 0 | 3523979 | 126629 | None | 3.4.6 | Supplyingandflushmountingpowdercoated/galvanizedmetalboxsuitableformountingmodularswitchplates.Theboxshouldbefirmlyflush mounted after due groove cutting in Brick/Stone/C.C wall 10-12 Way | Each | 319.0 | 319.0 | 1.0 | False | None | None | False | None | False | 319.0 | 0 | 3523980 | 126629 | None | 3.4.8 | Supplyingandflushmountingpowdercoated/galvanizedmetalboxsuitableformountingmodularswitchplates.Theboxshouldbefirmlyflush mounted after due groove cutting in Brick/Stone/C.C wall 18 Way | Each | 405.0 | 405.0 | 4.0 | False | None | None | False | None | False | 1620.0 | 0 | 3523981 | 126629 | None | 3.5.3 | Supplyingandfixingsuperiorqualitymodularswitchmountingpolycarbonateplatewithnecessarysupportingbackplatewithrequirednos.ofmachinescrews,boltsnutsetc.,completeontheexistingmetal/PVC box. 4 Module | Each | 175.0 | 175.0 | 2.0 | False | None | None | False | None | False | 350.0 | 0 | 3523982 | 126629 | None | 3.5.4 | Supplyingandfixingsuperiorqualitymodularswitchmountingpolycarbonateplatewithnecessarysupportingbackplatewithrequirednos.ofmachinescrews,boltsnutsetc.,completeontheexistingmetal/PVC box. 6 Module | Each | 234.0 | 234.0 | 2.0 | False | None | None | False | None | False | 468.0 | 0 | 3523983 | 126629 | None | 3.5.5 | Supplyingandfixingsuperiorqualitymodularswitchmountingpolycarbonateplatewithnecessarysupportingbackplatewithrequirednos.ofmachinescrews,boltsnutsetc.,completeontheexistingmetal/PVC box. 8 Module | Each | 284.0 | 284.0 | 10.0 | False | None | None | False | None | False | 2840.0 | 0 | 3523984 | 126629 | None | 3.5.6 | Supplyingandfixingsuperiorqualitymodularswitchmountingpolycarbonateplatewithnecessarysupportingbackplatewithrequirednos.ofmachinescrews,boltsnutsetc.,completeontheexistingmetal/PVC box. 10-12 Module | Each | 344.0 | 344.0 | 1.0 | False | None | None | False | None | False | 344.0 | 0 | 3523985 | 126629 | None | 3.5.8 | Supplyingandfixingsuperiorqualitymodularswitchmountingpolycarbonateplatewithnecessarysupportingbackplatewithrequirednos.ofmachinescrews,boltsnutsetc.,completeontheexistingmetal/PVC box. 18 Module | Each | 457.0 | 457.0 | 4.0 | False | None | None | False | None | False | 1828.0 | 0 | 3523986 | 126629 | None | 3.6.1 | Supplyingandfixingofmodularswitch&connectedaccessoriesonexisting modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch | Each | 102.0 | 102.0 | 76.0 | False | None | None | False | None | False | 7752.0 | 0 | 3523987 | 126629 | None | 3.6.3 | Supplyingandfixingofmodularswitch&connectedaccessoriesonexisting modular switch plate as per IS 3854 and IS 1293. 6A Three Way socket | Each | 171.0 | 171.0 | 18.0 | False | None | None | False | None | False | 3078.0 | 0 | 3523988 | 126629 | None | 3.6.5 | Supplyingandfixingofmodularswitch&connectedaccessoriesonexisting modular switch plate as per IS 3854 and IS 1293. 400W Dimmer | Each | 276.0 | 276.0 | 29.0 | False | None | None | False | None | False | 8004.0 | 0 | 3523989 | 126629 | None | 3.6.7 | Supplyingandfixingofmodularswitch&connectedaccessoriesonexisting modular switch plate as per IS 3854 and IS 1293. 16A One Way Switch | Each | 180.0 | 180.0 | 8.0 | False | None | None | False | None | False | 1440.0 | 0 | 3523990 | 126629 | None | 3.6.10 | Supplyingandfixingofmodularswitch&connectedaccessoriesonexisting modular switch plate as per IS 3854 and IS 1293. 6/16A Universal Socket | Each | 236.0 | 236.0 | 8.0 | False | None | None | False | None | False | 1888.0 | 0 | 3523991 | 126629 | None | 3.14.5 | Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board. 6A Bakelite Ceiling Rose | No | 78.0 | 78.0 | 29.0 | False | None | None | False | None | False | 2262.0 | 0 | 3523992 | 126629 | None | 3.14.7 | Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board. 6A Batten Holder | No | 74.0 | 74.0 | 20.0 | False | None | None | False | None | False | 1480.0 | 0 | 3523993 | 126629 | None | 5.6.5 | Supplyandfixingpolishedwoodboardmadeofnotlessthan15mmthickplankonbothsidesofnotmorethan2piecesandfixingthesametothewallusingtaperedinvertedwoodenplugsscrews. 15" x 12" x 2" | Each | 201.0 | 201.0 | 1.0 | False | None | None | False | None | False | 201.0 | 0 | 3523994 | 126629 | None | 5.7.4 | Supplying&fixingofPorcelainfusechannelwithcutoutonexisting wooden/panel using necessary nuts, bolts and washers 100 A | Each | 691.0 | 691.0 | 4.0 | False | None | None | False | None | False | 2764.0 | 0 | 3523995 | 126629 | None | 5.15.9 | SupplyingandfixingMouldedCaseCircuitBreaker(MCCB)overtheexistingwood/panelboardusingnecessaryscrews,bolts,nuts,necessaryphaseseparators,handleandwiringcomplete.ProtectionofOverloadandShortcircuitwithadjustablethermalmagneticrelease,MicroprocessorreleaseshallhaveEarthFaultasperIS/IEC60947-2.(Icu=100%lcs).In4PMCCB,allPolesshouldhaveprotectionforShort-Cicrcuit/OverLoad.ForMicroprocessorMCCBSFacilityforsegregatingPriorityandNon-PriorityloadsmustbeavailableintheMCCB.MCCBshallbeprovidedwithdoubleinsulation(insulationbetweenfrontcoverandinternalpowercircuitstoavoidanyaccidentalcontactwithlivecurrentcarryingpathwiththefrontcoveropen).Multi-polebreakersshallbedesignedtobreakallthepolessimultaneously and they shall have a single mechanism. FOUR Pole 100 A 25 kA | Each | 8487.0 | 8487.0 | 1.0 | False | None | None | False | None | False | 8487.0 | 0 | 3523996 | 126629 | None | 5.18.1 | Supplying&fixingminiaturecircuitbreakersonexistingMCBdistributionboardsusingnecessaryfixingmaterialsand'C'Typecurve,indicatorON/OFF,energycross-3withShortcircuitbreakingcapacityof10KandcompletewiringasrequiredconfirmingtoIEC60898.6-32 A SP | Each | 415.0 | 415.0 | 12.0 | False | None | None | False | None | False | 4980.0 | 0 | 3523997 | 126629 | None | 5.18.8 | Supplying&fixingminiaturecircuitbreakersonexistingMCBdistributionboardsusingnecessaryfixingmaterialsand'C'Typecurve,indicatorON/OFF,energycross-3withShortcircuitbreakingcapacityof10KandcompletewiringasrequiredconfirmingtoIEC60898. 40 A TPN | Each | 3044.0 | 3044.0 | 4.0 | False | None | None | False | None | False | 12176.0 | 0 | 3523998 | 126629 | None | 5.19.9 | SupplyingandfixingregularMCBdistributionboardsonwall/oodboard/flushmountingusingrequiredclamps,bolts,nutsetc.,withprovisionforfixingsuitabletypecapacityMCB'ssinglephase/3phase/singledoorwithpowdercoatedpaintingMadeoutof14SWGMS enclosure. II - Double Door 12 Way SP & N | Each | 2329.0 | 2329.0 | 2.0 | False | None | None | False | None | False | 4658.0 | 0 | 3523999 | 126629 | None | 5.29 | Supplying,fixingandwiring3PhaseDigitalAmmeter/Voltmeter | Each | 1425.0 | 1425.0 | 1.0 | False | None | None | False | None | False | 1425.0 | 0 | 3524000 | 126629 | None | 5.35 | Supplying,fixingandwiringElectronicTrivectorMeter(ETV)5to32/63Athreephase4wirewholecurrentclass-1AccuracyEnergyMeter. | Each | 5705.0 | 5705.0 | 1.0 | False | None | None | False | None | False | 5705.0 | 0 | 3524001 | 126629 | None | 5.38 | SupplyingandfixingofLEDtypepanelboardindicatinglampwith required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. | Each | 515.0 | 515.0 | 3.0 | False | None | None | False | None | False | 1545.0 | 0 | 3524002 | 126629 | None | 5.40.1 | Supplying.Arated3phasewithneutralbusbarusingrequiredcapacityelectrolyticaluminiumstripscoveredwithheatshrinkablecolouredPVCsleeve,mountedonphenolic/FRP/DMCinsulatorwhicharemountedonpowdercoated40x6mmM.S.flatframeworkinexistingpanelboard.ThebusbarshallhavesuitableholesforterminationofincomingandoutgoingcablesasperISspecification with necessary bolts, nuts and washers etc., complete 100 A 4 x 30 x 6 mm Aluminium Strips | m | 2465.0 | 2465.0 | 0.5 | False | None | None | False | None | False | 1232.5 | 0 | 3524003 | 126629 | None | 5.41.1 | SupplyingandfixingangleironframeworkfabricatedoutofM.S.angleiron.andM.S.Flat.withbolts,washersetc.,andpaintedwith 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mm | m | 305.0 | 305.0 | 6.0 | False | None | None | False | None | False | 1830.0 | 0 | 3524004 | 126629 | None | 5.42.2 | FabricatingsupplyingandmountingMSboxmadeout.SWGsuitableforfloor/wallmounting,fullyweatherproofwithprovisionforbetterheatdissipation,providedwithhingedfrontcover,equippedwithtamperprooflockingarrangements,withsuitablesizeclampswithnecessarycableentrypipewithglandandboxshouldbefinishedwith7tankstreatmentwithpowdercoatedpaintand finally finished with approved colour etc., complete 16 SWG | Sq CM | 0.43 | 0.43 | 50000.0 | False | None | None | False | None | False | 21500.0 | 0 | 3524005 | 126629 | None | 6.1 | Supplyingexhaustfanof1440RPMof300mm(12")sizewithbracketbladescompleteforlightdutysuitabletooperateon230V50Hz, AC Supply. | Each | 1492.0 | 1492.0 | 4.0 | False | None | None | False | None | False | 5968.0 | 0 | 3524006 | 126629 | None | 6.3.1 | Supplyingcapacitortypeceilingfancompletewithdownrodblades,shackle,canopiesetc,foroperationon230V,50cycles.SinglephaseACsupplyconformingtoISS-374-1979andwithdoubleballbearingsystem 48" Sweep (1200 mm) Regular model | Each | 2984.0 | 2984.0 | 27.0 | False | None | None | False | None | False | 80568.0 | 0 | 3524007 | 126629 | None | 13.10 | Fixingaceiling/Wallmountingfanofallcapacitiesandalltypestotheexisting'S''hookwithfanregulatortotheexistingboardtogetherwithsupplyingandfixing5A.ceilingrose,necessarylengthof23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 171.0 | 171.0 | 27.0 | False | None | None | False | None | False | 4617.0 | 0 | 3524008 | 126629 | None | 11.3.2 | Supplyingof.feet-PVCBattenwithintegratedLEDtube.WwithhighqualitydiffuserwithLifeof25000burninghours&70%lumenmaintenancewithCRIGREATER THAN80.PowerInput:220-240V@50/60Hz&PowerfactorGREATER THAN0.9alongwithCEapproved.2yearsWarrantyagainstanymanufacturingdefectworkingunderstandardelectrical condition. LED light fitting 1 x 4' - 20/22 W | Each | 690.0 | 690.0 | 6.0 | False | None | None | False | None | False | 4140.0 | 0 | 3524009 | 126629 | None | 13.7.1 | Fixingalltypesandallcapacitiesoffluorescent/falseceiling/spotlight/CFL/LEDfittingsindooronthewall/ceiling/rafters/girdersusing23/0.0076"twintwistedPVCinsulatedwires,requiredNosofround blocks and clamps On wall/ ceiling / Rafter / Girders | Each | 122.0 | 122.0 | 6.0 | False | None | None | False | None | False | 732.0 | 0 | 3524010 | 126629 | None | 11.9.2 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material,delivering superior light output. Rated life Burning Hrs 50000hr @ Lumen Maintenance of 70%, CCT greater than 5500K, IP 66optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiencygreater than 130lm/w, nominal CRI greater than75. Luminaire manufacturer should have inhouse facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/Lumileds /Osram make LED Source. LED Floodlight 100W | Each | 9486.0 | 9486.0 | 8.0 | False | None | None | False | None | False | 75888.0 | 0 | 3524011 | 126629 | None | 13.2.3 | SupplyingandFixing.mmdiaclampsssAGIpipebracketupto2.7meterslongterminatedwithareducingcollarof40x25mmtowhichextrapipeof175mmlengthisfixedforfixingMV/SV/MH/FTLstreetlightfittingofallcapacitiesonrail/RCC/wall/tubularpole,usingsuitableclamps,bolts,nutsandwiringusingsuitablecapacitywires. Using 40mm dia G.I.Pipe | Each | 1478.0 | 1478.0 | 8.0 | False | None | None | False | None | False | 11824.0 | 0 | 3524012 | 126629 | None | 13.5 | Fixinghalogen/metalhalide/SVL/IL/LEDfloodlightfittingoverexistingpole/wallceilingincludingclamps,bolts,nutsandwiringusing suitable capacity wires. | Each | 162.0 | 162.0 | 8.0 | False | None | None | False | None | False | 1296.0 | 0 | 3524013 | 126629 | None | 11.14.3 | Supplyingandfixingofslimboxfitting,madeoutofCRCASheetmetalbodywithlockingtypeholdercompletelywired.ExcludingBallast & Fluorescent Tube. 2 x 4' Tube light fitting. | Each | 421.0 | 421.0 | 11.0 | False | None | None | False | None | False | 4631.0 | 0 | 3524014 | 126629 | None | 12.56 | Supplying,fixing,wiring,earthelectrodeforgroundingconduits,I.C.cutoutsandotherequipment'sonthemeterboardusing40mmdia2.90mmthickGIpipe2.5mlongburiedinapit.Thepitshouldbefilledwithequalproportionofsaltandcharcoal150mmall-roundthepipetocompletedepth.Theconnectionfromthepipetotheconduitetc.,istobeestablishedthroughGIwireofsizeasperlSIspecification7.3.3.ofIS732using12mmdiabolts,nuts,washersandchecknutsetc., the pipe shall have 16 through holes of 12 mm dia | No | 3510.0 | 3510.0 | 1.0 | False | None | None | False | None | False | 3510.0 | 0 | 3524015 | 126629 | None | 32.09 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 35 Sqmm, 3.5 Core, (14 GI Strips - 4 x 0.8 mm) 287059 | Km | 154062.0 | 154062.0 | 0.03 | False | None | None | False | None | False | 4621.86 | 0 | 3524016 | 126629 | None | 33.04 | Compression type Aluminium Tubular in Line Connector for Aluminum Conductor 35 Sqmm 288608 | No | 4.0 | 4.0 | 8.0 | False | None | None | False | None | False | 32.0 | 0 | 3524017 | 126629 | None | 21.06 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 35 to 95 Sqmm | Km | 31139.0 | 31139.0 | 0.03 | False | None | None | False | None | False | 934.17 | 0 | 3524018 | 126629 | None | 29.03 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. In Hard Soil | Cum | 389.0 | 389.0 | 15.0 | False | None | None | False | None | False | 5835.0 | 0 | 3524019 | 126629 | None | 13.14 | Fixingoneexhaustfaninthenitchalreadyleftinthewallwithboltsandnutsand5A.ceilingrosewithsufficientlengthof23/0.0076inch PVC insulated twin core wire. | Each | 492.0 | 492.0 | 4.0 | False | None | None | False | None | False | 1968.0 | 0 |
|
|
---|