createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1721373515646
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyRESERVED
invitingStrategyTextReserved
taxTypeINCLUSIVE_TAX
tenderFee1230.00
emd49000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose05-08-2024 16:00:00
tenderQueryClose03-08-2024 16:00:00
technicalBidOpen06-08-2024 16:10:00
publishedDate20-07-2024 16:09:41
publishedByPostEWHFWD_EE_EEOFF_MYS
publishedByUserKPE12441 - H SRINIVASAGOWDA
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonAzra
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9449843319
tenderSupplierListNone
tenderSchedule
createdTs1721373515679
version4
createdDateNone
modifiedDateNone
tenderNumberEWHFWD/2024-25/BD/WORK_INDENT511
titleCONSTRUCTION OF BLOCK LEVEL PUBLIC HEALTH UNIT AT GH HOLENARASIPURA 2ND FLOOR IN HASSAN DISTRICT.
descriptionCONSTRUCTION OF BLOCK LEVEL PUBLIC HEALTH UNIT AT GH HOLENARASIPURA 2ND FLOOR IN HASSAN DISTRICT.
categoryWORKS
categoryTextWorks
ecv4901446.37
deptNameEngineering Wing of Health and Family Welfare Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3523
locationNameEWHFWD Executive Engineer Office Mysore
provisionalAmount5000000.0
groupOverheadTotal0.0
fileNumberHFW/AEE/HSN/BPHU/HNPura
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17213735160000NoneNoneBuildingsCONSTRUCTION OF BLOCK LEVEL PUBLIC HEALTH UNIT AT GH HOLENARASIPURA 2ND FLOOR IN HASSAN DISTRICT. (Civil Works)4105231.59
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3548726128322NoneI-19.7.1 P-187 V-2Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.Cum585.82585.828.63FalseNoneNoneFalseNoneFalse5055.62660
3548727128322NoneI-2.5.2 P-16 V-1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Columns (Centering & formwork are included) SFCum14421.6514421.657.82FalseNoneNoneFalseNoneFalse112777.3030
3548728128322NoneI-2.5.2 P-16 V-1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Centering & formwork are included) RCC BEAMS, LINTELS SFCum13573.3213573.3223.57FalseNoneNoneFalseNoneFalse319923.15240
3548729128322NoneI-2.5.2 P-16 V-1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Centering & formwork are included) RCC SLAB, STAIRCASE SFCum12724.9912724.9921.36FalseNoneNoneFalseNoneFalse271805.78640
3548730128322NoneI-2.1.4 P-15 V-1PProviding and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (Centering & formwork are included) SFCum7707.267707.2620.35FalseNoneNoneFalseNoneFalse156842.7410
3548731128322NoneI-15.4 P-135 V-3Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy SFNo.252.9252.930.0FalseNoneNoneFalseNoneFalse7587.00
3548732128322NoneI-2.11a P-18 V-1Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings SFTonne110900.55110900.556.27FalseNoneNoneFalseNoneFalse695346.44850
3548733128322NoneI-4.21 P-15 S.R 2018-19KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No . KBS SFRmtr40.9140.9140.32FalseNoneNoneFalseNoneFalse1649.49120
3548734128322NoneA.RProviding throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. SFRmtr86.1486.1450.0FalseNoneNoneFalseNoneFalse4307.00
3548735128322NoneI-6.32 P-17 V-2Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. SFSqm1624.021624.02307.98FalseNoneNoneFalseNoneFalse500165.67960
3548736128322NoneI-6.34 P-17 V-2Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. SFSqm1368.631368.6327.09FalseNoneNoneFalseNoneFalse37076.18670
3548737128322NoneI-12.13.1 P-100 V-2Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. SFCum122501.75122501.750.82FalseNoneNoneFalseNoneFalse100451.4350
3548738128322NoneI-12.51 P-104 V-2Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. SFNos1259.541259.5412.0FalseNoneNoneFalseNoneFalse15114.480
3548739128322NoneA.RProviding and fixing Aluminium fixtures like Aldrops of size 300 x 16 mm, Tower bolts of size 200 x 12 mm, Latches of size 250 x12 mm, 100 mm length oxidized Iron Hinges, Handles of size 150 mm, Door Stopper & Door Bush of approved make and quality including cost and conveyance of all materials and as per the direction of EIC of work with all lead and lift and as directed by the Engineer in charge of works. Single Shutter. (Locking Arrangements) SFNos2360.02360.012.0FalseNoneNoneFalseNoneFalse28320.00
3548740128322NoneI-10.6.3 P-69 V-2Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm SFNos74.3974.3972.0FalseNoneNoneFalseNoneFalse5356.080
3548741128322NoneI-313 (0115) P-XI S.R 2018-19Providing & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications. SFRmtr15.7515.7572.6FalseNoneNoneFalseNoneFalse1143.450
3548742128322NoneI-12.57.6 P-105 V-2Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial SFSqm4118.314118.3136.0FalseNoneNoneFalseNoneFalse148259.160
3548743128322NoneI-12.90 P-110 V-2Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) SFSqm8348.198348.1927.0FalseNoneNoneFalseNoneFalse225401.130
3548744128322NoneI-12.85 P-109 V-2Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) SFSqm7089.897089.891.62FalseNoneNoneFalseNoneFalse11485.62180
3548745128322NoneI-11.34A P-86 V-2Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding SFKg208.27208.27601.02FalseNoneNoneFalseNoneFalse125174.43540
3548746128322NoneI-12.54 P-104 V-2Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. SFm394.23394.233.15FalseNoneNoneFalseNoneFalse1241.82450
3548747128322NoneI-12.55.2 P-104 V-2Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. with one side prelam SFSqm2529.02529.03.15FalseNoneNoneFalseNoneFalse7966.350
3548748128322NoneI-12.59 P-105 V-2Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. SFNos1381.041381.0412.0FalseNoneNoneFalseNoneFalse16572.480
3548749128322NoneI-11.35.2.1 P-88 V-2Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to re- quired shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials,labour,usage charges of machinery complete as per specifications. SFKg662.0662.028.8FalseNoneNoneFalseNoneFalse19065.60
3548750128322NoneI-11.36.1 P-89 V-2Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in- charge: Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side including cost of materials, labour, usage charges of machinery complete as per specifications. SFSqm1112.021112.021.44FalseNoneNoneFalseNoneFalse1601.30880
3548751128322NoneI-11.37.1 P-89 V-2Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. SFSqm1224.831224.831.44FalseNoneNoneFalseNoneFalse1763.75520
3548752128322NoneI-8.5.2 P-42 V-2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Inside) SFSqm432.66432.66289.41FalseNoneNoneFalseNoneFalse125216.13060
3548753128322NoneI-8.10 P-43 V-2Providing 6 mm cement plaster with cement mortar 1:3 (1 cement: 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SFSqm261.58261.58126.96FalseNoneNoneFalseNoneFalse33210.19680
3548754128322NoneI-8.51 P-50 V-2Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. SFSqm123.97123.97512.65FalseNoneNoneFalseNoneFalse63553.22050
3548755128322NoneI-8.8 P-42 V-2Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. . (outside) SFSqm459.93459.93221.68FalseNoneNoneFalseNoneFalse101957.28240
3548756128322NoneI-8.3.1 P-41 V-2Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SFSqm438.85438.8518.32FalseNoneNoneFalseNoneFalse8039.7320
3548757128322NoneI-15.36 P-118 S.R 2018-19KSRB 15.8.3 Providing and fixing plaster mesh 200mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per Sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment ) SFRmtr44.6344.63294.4FalseNoneNoneFalseNoneFalse13139.0720
3548758128322NoneI-6.12 P-14 V-2Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:3 (1 cement : 3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. SFCum1243.431243.437.2FalseNoneNoneFalseNoneFalse8952.6960
3548759128322NoneI-7.18 P-23 V-2Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. SFCum2500.492500.491.95FalseNoneNoneFalseNoneFalse4875.95550
3548760128322NoneI-15.7 P-150 V-2Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) SFSqm762.42762.4237.55FalseNoneNoneFalseNoneFalse28628.8710
3548761128322NoneI-10.5.2 P-70 S.R 2018-19Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer.Sqm267.78267.7825.0FalseNoneNoneFalseNoneFalse6694.50
3548762128322NoneI-8.79 P-54 V-2Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. SFRmtr64.4664.46216.67FalseNoneNoneFalseNoneFalse13966.54820
3548763128322NoneI-9.21.2 P-62 V-2Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).). Size of Tile 600x600 mm SFSqm1534.761534.76142.52FalseNoneNoneFalseNoneFalse218733.99520
3548764128322NoneI-8.2.1 P-41 V-2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SFSqm365.72365.72217.95FalseNoneNoneFalseNoneFalse79708.6740
3548765128322NoneI-9.9 P-60 V-2Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. SFSqm1333.931333.936.5FalseNoneNoneFalseNoneFalse8670.5450
3548766128322NoneI-9.39 P-65 V-2Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. SFSqm1796.341796.34217.95FalseNoneNoneFalseNoneFalse391512.3030
3548767128322NoneI-8.39 P-48 V-2Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SFSqm157.45157.45512.65FalseNoneNoneFalseNoneFalse80716.74250
3548768128322NoneI-8.30 P-46 V-2Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SFSqm215.7215.7221.68FalseNoneNoneFalseNoneFalse47816.3760
3548769128322NoneI-8.40 P-48 V-2Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SFSqm142.57142.5728.62FalseNoneNoneFalseNoneFalse4080.35340
3548770128322NoneI-8.34.1 P-47 V-2Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SFSqm65.765.779.49FalseNoneNoneFalseNoneFalse5222.4930
3548771128322NoneI-8.38 P-48 V-2Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SFSqm49.5849.5879.49FalseNoneNoneFalseNoneFalse3941.11420
3548772128322NoneI-10.1.2 P-69 V-2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 GFSqm4880.734880.737.2FalseNoneNoneFalseNoneFalse35141.2560
17213735160000NoneNoneBuildingsCONSTRUCTION OF BLOCK LEVEL PUBLIC HEALTH UNIT AT GH HOLENARASIPURA 2ND FLOOR IN HASSAN DISTRICT. (Water Supply & Sanitary Works)276996.14
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3548773128323NoneV-2 P-122 I- 13.31.2Providing and fixing Chorinated Poly Vinyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1 00 mtr spacing. This includes JOinting of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (internal work exposed on wall) 20 mm nominal dia Pipes SFRmtr300.02300.0260.0FalseNoneNoneFalseNoneFalse18001.20
3548774128323NoneV-2 P-122 I- 13.31.3Providing and fixing Chorinated Poly Vinyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1 00 mtr spacing. This includes JOinting of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (internal work exposed on wall) 25 mm nominal dia Pipes SFRmtr394.23394.2340.0FalseNoneNoneFalseNoneFalse15769.20
3548775128323NoneV-2 P-117 I- 13.2.1Providing and fixing in position brass bib cock of approved quality 15mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. SFNos354.55354.554.0FalseNoneNoneFalseNoneFalse1418.20
3548776128323NoneV-2 P-117 I- 13.4.1Providing and fixing in position brass gate valve with C.I wheel of approved quality ( screwed end ) 20mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. 25 mm Dia SFNos680.6680.64.0FalseNoneNoneFalseNoneFalse2722.40
3548777128323NoneV-2 P-117 I- 13.4.2Providing and fixing in position brass gate valve with C.I wheel of approved quality ( screwed end ) 20mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. 32 mm Dia SFNos741.35741.354.0FalseNoneNoneFalseNoneFalse2965.40
3548778128323NoneV-2 P-132 I-14.7.1KSRB 11-11.1 : Providing and fixing white vitreous china clay, flat back wash basin size 630x450mm with a pair of 15mm C.P brass pillar taps with C.I / M.S brackets, 32 mm C.P. brass waste of standard pattern, painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete as per specifications. Specification No. KBS 11 SFNos3820.783820.783.0FalseNoneNoneFalseNoneFalse11462.340
3548779128323NoneV-2 P-137 I-14.40.2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. SFNos614.9614.93.0FalseNoneNoneFalseNoneFalse1844.70
3548780128323NoneV-2 P-136 I-14.32.2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm SFNos1262.021262.023.0FalseNoneNoneFalseNoneFalse3786.060
3548781128323NoneV-2 P-138 I-14.47Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc in cluding making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge SFNos17618.7317618.732.0FalseNoneNoneFalseNoneFalse35237.460
3548782128323NoneI-12.113.1 PWD S.R 2018-19Providing and fixing CI Nahani trap of approved make conforming to ISI specifications and construction of Cistern in CC 1:2:4 as per directions (Rate is inclusive of cost of materials and fixtures and conveyance of materials to work spot). For 10cms x 7.5cms SFNos309.93309.937.0FalseNoneNoneFalseNoneFalse2169.510
3548783128323NoneV-2 P-125 I-13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter SFRmtr360.75360.7580.0FalseNoneNoneFalseNoneFalse28860.00
3548784128323NoneV-2 P-128 I-13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75MM DIA SFRmtr358.27358.2730.0FalseNoneNoneFalseNoneFalse10748.10
3548785128323NoneV-2 P-128 I-13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110MM DIA SFRmtr477.29477.2940.0FalseNoneNoneFalseNoneFalse19091.60
3548786128323NoneV-2 P-126 I-13.53KSRB 12-8.1 : Constructing brick masonry inspection chamber 455x610mm, and 450mm depth, ( clear inside dimension ) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover with frame (light duty) 455x610mm internal dimensions, total weight of cover with frame to be not less than 38 kg ( weight of cover 23kg and weight of frame 15 kg) R.C.C. top slab with cement concrete M15 with 20mm and downsize granite metal, foundation concrete M5 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specifications. GFNos6857.296857.292.0FalseNoneNoneFalseNoneFalse13714.580
3548787128323NoneV-2 P-126 I-13.54KSRB 12-8.2 : Constructing brick masonry inspection chamber 500x700mm, and 450mm depth, ( clear inside dimension ) for pipeline with one or two inlets, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover with frame (light duty) 500x700mm internal dimensions, total weight of cover with frame to be not less than 38 kg ( weight of cover 23kg and weight of frame 15 kg ) R.C.C. top slab with cement concrete M15 with 20mm and downsize granite metal , foundation concrete M5 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finished smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specifications. GFNos7630.287630.282.0FalseNoneNoneFalseNoneFalse15260.560
3548788128323NoneP-6 V-1 I-1.6.1KSRB 2-2.2 : Earthwork excavation for foundation of buildings, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in hard soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50 m. after breaking of clods complete as per specifications. specification. No. KBS 2.1(b) / 2.3.5 Add Extra Rate of 50 % for EWE for Width lesser than 600mmCum588.25588.2522.0FalseNoneNoneFalseNoneFalse12941.50
3548789128323NoneV-1 I-1.10 P-7KSRB 2-4 : Refilling available earth around pipe lines, cables in layers not exceeding 20cms in depth, compacting each deposited layer by ramming after watering with lead upto 50m. and lift upto 1.5 m. including cost of all labour complete as per specifications allow 60% of rate considered under item KSRB 2.3Cum194.46194.4622.0FalseNoneNoneFalseNoneFalse4278.120
3548790128323NoneP.No270 I.No.37.35 PWD S.R 2018-19Making Wall bores in Brick masonry upto 45 cm thick width for soil / water pipes including redoing with C.M ( 1:4 ) with all lead and lift as directed by Engineer-in-charge. SFNos153.14153.1415.0FalseNoneNoneFalseNoneFalse2297.10
3548791128323NoneP.No.273 I.No.37.28.2 PWD S.R 2018-19Making Terrace Bores Or Chejja bore and including redoing with C.M ( 1:4 ) with all lead and lift as directed by Engineer-in-charge. SFNos194.63194.636.0FalseNoneNoneFalseNoneFalse1167.780
3548792128323NoneP.No.90 I.No.12.111 PWD S.R 2018-19Providing and fixing 7.5 cms to 15.00 cms dia NP grating 100mm dia. SFNos182.31182.317.0FalseNoneNoneFalseNoneFalse1276.170
3548793128323NoneV-2 P-117 I-13.5.1KSRB13-6.4-1 : Providing and fixing in position brass ball valve high or low pressure with plastic float of approved quality 15mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. SFNos366.96366.962.0FalseNoneNoneFalseNoneFalse733.920
3548794128323NoneV-2 P-123 I-13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank SFEach11.1611.161000.0FalseNoneNoneFalseNoneFalse11160.00
3548795128323NoneA.RProviding & fixing approved quality aquaguard water purifier, etc complete as per specificationEach25960.025960.01.0FalseNoneNoneFalseNoneFalse25960.00
3548796128323NoneA.RProviding & fixing 1 HP Mono block pump of approved make with all accessories etc.., complete including cost of materials, labour as per specifications.& as per the direction of the Engineer - in - chargeEach8260.08260.01.0FalseNoneNoneFalseNoneFalse8260.00
3548797128323NonePage no 134 ,item no 14.11.2 V-2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required Size 600x450x200 mm SFEach6300.26300.24.0FalseNoneNoneFalseNoneFalse25200.80
3548798128323NonePage no 136 ,item no 14.28.1.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete 40 mm dia SFEach109.09109.094.0FalseNoneNoneFalseNoneFalse436.360
3548799128323NonePage no 136 ,item no 14.29 V-2Providing and fixing 100 mm sand cast Iron grating for gully trap. SFEach58.2758.274.0FalseNoneNoneFalseNoneFalse233.080
17213735160000NoneNoneBuildingsCONSTRUCTION OF BLOCK LEVEL PUBLIC HEALTH UNIT AT GH HOLENARASIPURA 2ND FLOOR IN HASSAN DISTRICT. (Electrical Works)519218.64
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3548800128324None2.2.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switchPoint460.64460.649.0FalseNoneNoneFalseNoneFalse4145.760
3548801128324None2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switchPoint674.55674.5515.0FalseNoneNoneFalseNoneFalse10118.250
3548802128324None2.2.4Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switchesPoint822.83822.8320.0FalseNoneNoneFalseNoneFalse16456.60
3548803128324None3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2WayEach167.73167.7320.0FalseNoneNoneFalseNoneFalse3354.60
3548804128324None3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3WayEach193.25193.255.0FalseNoneNoneFalseNoneFalse966.250
3548805128324None3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5WayEach215.13215.135.0FalseNoneNoneFalseNoneFalse1075.650
3548806128324None3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6 WayEach267.39267.3910.0FalseNoneNoneFalseNoneFalse2673.90
3548807128324None3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8WayEach317.22317.2212.0FalseNoneNoneFalseNoneFalse3806.640
3548808128324None3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 ModuleEach166.51166.5120.0FalseNoneNoneFalseNoneFalse3330.20
3548809128324None3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 ModuleEach212.7212.75.0FalseNoneNoneFalseNoneFalse1063.50
3548810128324None3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 ModuleEach284.4284.45.0FalseNoneNoneFalseNoneFalse1422.00
3548811128324None3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 ModuleEach345.17345.1710.0FalseNoneNoneFalseNoneFalse3451.70
3548812128324None3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 ModuleEach418.1418.112.0FalseNoneNoneFalseNoneFalse5017.20
3548813128324None3.6.1Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293. (16/3.7) 6Amps one way SwitchEach123.97123.9784.0FalseNoneNoneFalseNoneFalse10413.480
3548814128324None3.6.3Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293. (16/3.7) 6Amps 3way socketEach207.83207.8340.0FalseNoneNoneFalseNoneFalse8313.20
3548815128324None3.6.4Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293. (16/3.7) Stepped Fan Regulator.Each433.9433.99.0FalseNoneNoneFalseNoneFalse3905.10
3548816128324None3.6.8Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Is 3854 and IS 1293. (16/3.7) 6A Bell PushEach215.13215.134.0FalseNoneNoneFalseNoneFalse860.520
3548817128324None3.6.10Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Is 3854 and IS 1293. (16/3.7) 6/16A Universal SocketEach286.83286.836.0FalseNoneNoneFalseNoneFalse1720.980
3548818128324None3.6.11Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Is 3854 and IS 1293. (16/3.7) TV/Telephone SocketEach189.6189.614.0FalseNoneNoneFalseNoneFalse2654.40
3548819128324None3.6.12Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293. (16/3.7) RJ45/ I.O. outletEach409.59409.594.0FalseNoneNoneFalseNoneFalse1638.360
3548820128324NoneI-1.12Supplyin and Fixing Metal Fan Box with Round Hook.No194.46194.469.0FalseNoneNoneFalseNoneFalse1750.140
3548821128324None1.1.1Open Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.(2/1.1) 19/20mm dia 2mm thickm83.8683.86400.0FalseNoneNoneFalseNoneFalse33544.00
3548822128324None1.1.2Open Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.(2/1.1) 25mm dia 2mm thickm98.4598.45250.0FalseNoneNoneFalseNoneFalse24612.50
3548823128324None1.1.3Open Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.(2/1.1) 32mm dia 2.5mm thickm128.83128.83100.0FalseNoneNoneFalseNoneFalse12883.00
3548824128324None1.3.1Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.(2/1.3) 19/20mm dia 2mm thickm82.6582.65180.0FalseNoneNoneFalseNoneFalse14877.00
3548825128324None1.3.2Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.(2/1.3) 25mm dia 2mm thickm96.0296.02220.0FalseNoneNoneFalseNoneFalse21124.40
3548826128324None1.3.3Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.(2/1.3) 32mm dia 2.5mm thickm120.32120.3240.0FalseNoneNoneFalseNoneFalse4812.80
3548827128324None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmmm31.631.6200.0FalseNoneNoneFalseNoneFalse6320.00
3548828128324None2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmmm51.0551.05500.0FalseNoneNoneFalseNoneFalse25525.00
3548829128324None2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmmm76.5776.57300.0FalseNoneNoneFalseNoneFalse22971.00
3548830128324None2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmmm111.82111.82200.0FalseNoneNoneFalseNoneFalse22364.00
3548831128324NoneI-8.1Supplying and drawing UTP-CAT 6E LAN cable.m46.1946.19100.0FalseNoneNoneFalseNoneFalse4619.00
3548832128324None8.2.2Supplying and drawing PVC flexible 2 pair telepone unarmoured tinned copper cable.m25.5225.52100.0FalseNoneNoneFalseNoneFalse2552.00
3548833128324None11.3.2Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 wEach838.63838.6321.0FalseNoneNoneFalseNoneFalse17611.230
3548834128324None11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18WEach1609.191609.196.0FalseNoneNoneFalseNoneFalse9655.140
3548835128324None11.11.3Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per watt, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should lesser than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500KEach181.09181.094.0FalseNoneNoneFalseNoneFalse724.360
3548836128324NoneI-6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1813.381813.384.0FalseNoneNoneFalseNoneFalse7253.520
3548837128324None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular modelEach3626.753626.759.0FalseNoneNoneFalseNoneFalse32640.750
3548838128324None13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / GirdersEach148.28148.2827.0FalseNoneNoneFalseNoneFalse4003.560
3548839128324NoneI-13.10Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each207.83207.839.0FalseNoneNoneFalseNoneFalse1870.470
3548840128324NoneI-13.11Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.Each382.85382.854.0FalseNoneNoneFalseNoneFalse1531.40
3548841128324None5.19.11Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure Double Door 4 Way TPN DBEach4907.794907.792.0FalseNoneNoneFalseNoneFalse9815.580
3548842128324None5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SPEach504.39504.3924.0FalseNoneNoneFalseNoneFalse12105.360
3548843128324None5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPNEach3699.683699.686.0FalseNoneNoneFalseNoneFalse22198.080
3548844128324None5.20.8Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 32-40 Amps 4 poleEach6255.666255.662.0FalseNoneNoneFalseNoneFalse12511.320
3548845128324None5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWGSq CM0.520.5260000.0FalseNoneNoneFalseNoneFalse31200.00
3548846128324None5.40.1Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Stripsm2995.962995.963.0FalseNoneNoneFalseNoneFalse8987.880
3548847128324None5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mmm370.7370.76.0FalseNoneNoneFalseNoneFalse2224.20
3548848128324None5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channelm918.84918.846.0FalseNoneNoneFalseNoneFalse5513.040
3548849128324None5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism FOUR POLE 100Amps 25kAEach10315.110315.11.0FalseNoneNoneFalseNoneFalse10315.10
3548850128324NoneI-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.CEach625.93625.933.0FalseNoneNoneFalseNoneFalse1877.790
3548851128324NoneI-5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape WoundEach683.05683.053.0FalseNoneNoneFalseNoneFalse2049.150
3548852128324NoneI-5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracyEach11321.4511321.451.0FalseNoneNoneFalseNoneFalse11321.450
3548853128324NoneI-32.09Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 3.5 core 35 sqmmKm187246.95187246.950.05FalseNoneNoneFalseNoneFalse9362.34750
3548854128324None21.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 to 95 SqmmKm37846.3437846.340.05FalseNoneNoneFalseNoneFalse1892.3170
3548855128324None6.11.4 Ele S.R 2019-20Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 45mm diaEach235.79235.794.0FalseNoneNoneFalseNoneFalse943.160
3548856128324None6.9.2 Ele S.R 2019-20Supplying and fixing of class A (medium duty) GI pipe of wall thickness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV. 50mmm461.85461.8510.0FalseNoneNoneFalseNoneFalse4618.50
3548857128324None6.17.8 Ele S.R 2019-20Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 35 sqmm Long BarrelEach38.8938.898.0FalseNoneNoneFalseNoneFalse311.120
3548858128324NoneI-12.57Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.No5172.745172.742.0FalseNoneNoneFalseNoneFalse10345.480
3548859128324None12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI stripm99.6699.6620.0FalseNoneNoneFalseNoneFalse1993.20
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17213735170000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17213735170000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17213735170000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17213735170000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17213735170000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17213737240000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidderNone
17213737330000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costsNone
17213737430000NoneNoneELIGIBILITYConditional tenders will not be acceptedNone
17213737560000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner.None
17213737640000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to time.None
17213737750000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejected.None
17213737880000NoneNoneELIGIBILITYEarnest Money Deposit will have to be in any one of the forms as per the instructions in the financial bid document and shall have to be valid for 45 days beyond the validity of the tender.None
17213737980000NoneNoneELIGIBILITYAll formats prescribed in the bid documents shall be filled in complete manner (section 2 & of the bid document)and shall be uploaded properly, signed by tenderer. Necessary certificates shall be uploaded along with the formats wherever required. General documents section can be used for this purposeNone
17213738060000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bidNone
17213738470000NoneNoneELIGIBILITYIf the tenderer quotes bid price below the estimated contract value (Amount put to tender) then the tenderer has to submit the additional security deposit equal to the difference in cost and the additional security deposit should have a validity for the period of execution.None
17213738580000NoneNoneELIGIBILITYIf the numbers of page to be attached in one particular attachment is more, then all the pages can be put into one folder, zipped and then attached or else all the pages can be pasted in one word file and then this word file could be converted to PDF (portable documents format) format and then attached. (Please contract help desk from 9.00 AM to 9.00 PM ( Monday to Saturday) Ph No: 91-8046010000 and 91-8068948777 or send query through Karnataka public procurement portal through query option on or before specified time.None
17213738710000NoneNoneELIGIBILITYThe Contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoid damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operation.None
17213738850000NoneNoneELIGIBILITYMaterials like, steel (primary), cement, bitumen etc., required for the work shall be procured by the tenderer themselves and should be got tested positive by the quality control authority before use on the work.None
17213739010000NoneNoneELIGIBILITYTenderer should have latest GST Registration and latest clearance certificate in their nameNone
17213739130000NoneNoneELIGIBILITYThe Rates quoted by the tenderer shall be inclusive of GST.None
17213739290000NoneNoneELIGIBILITYSpecial Instructions to tenderers - as per bid document.None
17213739410000NoneNoneELIGIBILITYThe Defects Liability Period is 1 year from the date of completion of the workNone
17213739490000NoneNoneELIGIBILITYTotal value of Civil Engineering Construction works executed in the and payments received in the last five year i.e., 2019-20, 2020-21, 2021-22, 2022-23 & 2023-24.None
17213739590000NoneNoneELIGIBILITYThe Tenderers are bound to furnish the original certified documents to the employer within 3 days from the day of opening of technical bid for verification, failing which the bid of tenderer will be considered as technically non responsive.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneClause ITT 3.2 b)To qualify for award of this contract, each tenderer in its name should have in the last five years i.e. (2019-20 to 2023-24) b) Satisfactorily completed as prime contractor, at least any construction work of value not less than of Rs. 12.25 Lakhs (25% of the cost of the work) Note : The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (b).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause ITT 3.2 c)The Tenderer or his identified sub-contractor should possess required valid electrical license for executing building electrification works issued by KPWD/Government Electrical Inspectorate and should have executed similar building electrical works in the last five years i.e (2019-20 to 2023-24) totaling Rs.2.50 Lakhs in any one financial year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (d). The letter of willingness of the sub contractor to be engaged for electrical works should be obtained and uploaded in the e-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause ITT 3.2d)The Tenderer or his identified sub-contractor should possess valid license for executing water supply/sanitary engineering works issued by BWSSB/KUWS&DB and should have executed similar building water supply/sanitary engineering works in the last five years i.e (2019-20 to 2023-24) totaling Rs. 1.30 Lakhs in any one financial year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (e). The letter of willingness of the sub contractor to be engaged for water Supply works should be obtained and uploaded in the e-portalPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.3 Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated for prime contractor are as under Assessed available tender capacity AxNx5.0- B Where A maximum value of civil engineering works executed in any one year during the last five years 2019-20 to 2023-24 updated to 2024-25 price level taking into account the completed as well as works in progress. N Number of years prescribed for completion of the works for which tenders are invited. B Value, at 2023 24 price level of existing commitments and ongoing works to be completed during the next 6 months. Note. The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneKPWD class-III & above Registration CertificateCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneReserved Category Certificate of Schedule CasteCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- cast certificate
NoneNoneNoneNoneGST CertificateCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- GST Certificate
NoneNoneNoneNoneClause ITT 3.2 a)To qualify for award of this contract, each tenderer in its name should have in the last five years i.e. (2019-20 to 2023-24) a)achieved in at least one financial year a minimum financial turnover (in all classes of civil engineering construction works only) of Rs.49.00 Lakhs. Note : a) For Clause 3.2 (a) the certificate duly certified by the charted accountant is to be submitted.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Reserved Category Certificate of Schedule CasteTrueTechnical Bid
Work done Certificate to issued not below the rank of Executive EngineerbeTrueTechnical Bid
GST CertificateTrueTechnical Bid
KPWD class-III & above Registration CertificateTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone